Loading...
HomeMy WebLinkAboutB12-0254 OBSERVATION OF EXCAVATION 090612G 000** H tech HEPWORTH - PAWLAK GEOTECHNICAL August 29, 2012 Slopeside Construction, Inc. Attn: Mike Dantas 2121 North Frontage Road West PMB 206 Vail, Colorado 81657 (mikedantas@comcast.net) -oASH Hepworth - Pawlak Geotechnical, Inc. 5020 County Road 154 Glenwood Springs, Colorado 81601 Phone: 970- 945 -7988 Fax: 970-945-8454 email: hpgeo@hpgeotech.com FE 0 W FE 5 SEP e s 2u12 TOWN OF VAIL Job No. 112 293A Subject: Observation of Excavation, Proposed New Entryway Canopy, Holiday Inn, 2211 North Frontage Road West, Vail, Colorado Dear Mike: As requested, a representative of Hepworth - Pawlak Geotechnical, Inc. observed the excavation at the subject site on August 28, 2012 to evaluate the soils exposed for foundation support. The findings of our observations and recommendations for the foundation design are presented in this report. The services were performed in accordance with our agreement for professional engineering services to Slopeside Construction, Inc., dated August 28, 2012. The new entryway canopy will be on the east side of the building. The structure has been designed to be supported on four isolated footing pads. The footings were sized assuming an allowable soil bearing pressure of 1,500 psf. At the time of our site visit, the foundation excavation for the four footing pads was essentially complete and had each been cut in one level from about 3%Z to 5 feet below the adjacent ground surface. The soils exposed in the bottom of the excavations consisted of medium stiff, sandy silty clay. Results of swell - consolidation testing performed on samples taken from the site, shown on Figure 1, indicate the soils are moderately compressible under conditions of loading and wetting. No free water was encountered in the excavations and the soils were generally moist. Considering the conditions exposed in the excavations and the nature of the proposed construction, spread footing pads placed on the undisturbed natural soil designed for an allowable bearing pressure of 1,500 psf can be used for support of the proposed canopy addition. There could be some differential settlement with respect to the existing structure which should be considered in the design. The footing pads should be a minimum width of 2 feet. Loose and disturbed soils in footing areas should be removed and the bearing level extended down to the undisturbed natural soils and the subgrade compacted. The footings should be provided with adequate soil cover above their bearing elevations for frost protection. The foundation backfill should be compacted to at least Parker 303 - 841 -7119 • Colorado Springs 719- 633 -5562 • Silverthorne 970- 468 -1989 Slopeside Construction, Inc. August 29, 2012 Page 2 95% of standard Proctor density at a moisture content near optimum and the surface graded to prevent ponding within at least 10 feet of the building and the footing pads. The recommendations submitted in this letter are based on our observation of the soils exposed within the footing pad excavations and do not include subsurface exploration to evaluate the subsurface conditions within the loaded depth of foundation influence. This study is based on the assumption that soils beneath the footings have equal or better support than those exposed. The risk of foundation movement may be greater than indicated in this report because of possible variations in the subsurface conditions. In order to reveal the nature and extent of variations in the subsurface conditions below the excavation, drilling would be required. It is possible the data obtained by subsurface exploration could change the recommendations contained in this letter. If you have any questions or need further assistance, please call our office. Sincerely, HEPWORTH — AK GAF EICAL, INC. 0.6 / ��� 0 �8'�p'eyr�a� .` C o David A. Young, P.E. -o! ..'o . 2 -215 i DAY /ljg °�� R`s °••..... «••aa����` attachment: Figure 1, Swells i Mation Test Results Job No. 112 293A GecPtec4h Moisture Content = 18.7 percent Dry Density = 97 pcf Sample of: Sandy Silty Clay From: Bottom of NE Pad Excavation 0 1 o z 2 Compression upon wetting O U) U) cc 3 0- 2 O U 4 5 6 7 8 9 10 11 0.1 1.0 10 100 APPLIED PRESSURE (ksf ) 112 293A G@ 1 tech HEPWORTH- PAWLAK GEOTECHNICAL SWELL- CONSOLIDATION TEST RESULTS FIGURE 1