SCALE:ELECTRICAL PLAN 1/16" = 1'-0"SHEET TITLE:VAIL, COLORADO VAIL VALLEY MEDICAL CENTER - PARKING LOT LIGHTINGEAUDINANZECOPYRIGHT 2010 BG Vail:Denver:Fort Collins:Albuquerque:www.bgce.com(970)949-6108 (303) 278-3820 (970) 221-5691 (505) 323-9070 E1ELECTRICALPLAN
LOAD SUMMARY for L1C (225AMP, 208/120 VOLT, 3‐PHASE)MEASURED PEAK DEMAND PER 30 DAY METERING (05/06/12)20.2KW LOAD REMOVED1.5KW SUBTOTAL18.7KW PEAK DEMAND WITH LOAD REMOVED18.7KW NEC DEMAND FACTOR1.25 NEC CORRECTED LOAD23.4KW LOAD ADDED8.3KW NEW LOAD ON DPA32KW 38AMPS MCC BUS RATING225AMPS OVERCURRENT PROTECTION RATING200AMPSLUMINAIRE SCHEDULE
TY
P
E
D
E
S
C
R
I
P
T
I
O
N
M
O
U
N
T
I
N
G
LAMPSINPUT WATTSVOLTMANUFACTURERCATALOG NUMBERSPECIFICNOTESQTYTYPE
LF
1
2
H
E
A
D
M
E
A
T
A
L
H
A
L
L
I
D
E
A
R
E
A
L
U
M
I
N
A
I
R
E
,
S
Y
M
M
E
T
R
I
C
SQ
U
A
R
E
D
R
O
P
L
E
N
S
E
,
W
I
T
H
1
6
'
D
A
R
K
B
R
O
N
Z
E
P
O
L
E
SQUARE POLE MOUNTING1METAL HALLIDE916208LITHONIA LIGHTINGKVR2 400M SYMDL
LF
2
ME
T
A
L
H
A
L
L
I
D
E
A
R
E
A
L
U
M
I
N
A
I
R
E
,
T
Y
P
E
I
V
F
O
R
W
A
R
D
TH
R
O
W
W
I
D
E
,
W
I
T
H
1
6
'
D
A
R
K
B
R
O
Z
E
P
O
L
E
SQUARE POLE MOUNTING1METAL HALLIDE458208LITHONIA LIGHTINGKVR2 400M SR4WFL
LF
3
ME
T
A
L
H
A
L
L
I
D
E
A
R
E
A
L
U
M
I
N
A
I
R
E
,
T
Y
P
E
I
V
F
O
R
W
A
R
D
TH
R
O
W
W
I
D
E
,
W
A
L
L
M
O
U
N
T
I
N
G
WALL MOUNTING1METAL HALLIDE458208LITHONIA LIGHTINGKVR2 400M SR4WFL
GE
N
E
R
A
L
N
O
T
E
S
:
A.
TH
E
L
U
M
I
N
A
I
R
E
S
C
H
E
D
U
L
E
C
A
N
N
O
T
B
E
U
S
E
D
I
N
D
E
P
E
N
D
E
N
T
L
Y
O
F
T
H
E
D
R
A
W
I
N
G
S
A
N
D
S
P
E
C
I
F
I
C
A
T
I
O
N
S
T
O
O
B
T
A
I
N
L
U
M
I
N
A
I
R
E
C
O
S
T
S
.
T
H
E
I
N
D
I
V
I
D
UAL ESTABLISHING LUMINAIRE COSTS SHALL
NO
T
Q
U
O
T
E
P
R
I
C
I
N
G
W
I
T
H
O
U
T
F
I
R
S
T
S
E
E
I
N
G
A
P
P
L
I
C
A
B
L
E
E
L
E
C
T
R
I
C
A
L
D
R
A
W
I
N
G
S
A
N
D
E
L
E
C
T
R
I
C
A
L
D
I
V
I
S
I
O
N
SPECIFICATIONS. THE CONTRACTOR IS REPONSIBLE FOR PROVIDING NECESSARY
DR
A
W
I
N
G
S
A
N
D
S
P
E
C
I
F
I
C
A
T
I
O
N
S
T
O
T
H
E
I
N
D
I
V
I
D
U
A
L
Q
U
O
T
I
N
G
L
U
M
I
N
A
I
R
E
P
R
I
C
I
N
G
.
B.
RE
F
E
R
T
O
D
R
A
W
I
N
G
S
F
O
R
F
I
X
T
U
R
E
S
R
E
Q
U
I
R
I
N
G
E
M
E
R
G
E
N
C
Y
B
A
T
T
E
R
Y
B
A
C
K
U
P
O
P
T
I
O
N
(
S
H
O
W
N
B
Y
H
A
T
C
H
I
N
/
O
V
E
R
S
Y
M
B
O
L
)
.
M
I
N
I
M
U
M
L
I
G
H
T
O
U
T
P
U
T
FOR EM BALLAST SHALL BE 600 LUMENS.
C.
A
L
L
F
L
U
O
R
E
S
C
E
N
T
L
A
M
P
S
A
R
E
T
O
B
E
3
5
0
0
°
K
E
L
V
I
N
C
O
L
O
R
T
E
M
P
E
R
A
T
U
R
E
SP
E
C
I
F
I
C
N
O
T
E
S
:
(1
)
(2
)
(3
)
(4
)
PO
L
E
B
A
S
E
D
I
A
G
R
A
M
NO
S
C
A
L
E
PA
R
T
I
A
L
E
L
E
C
T
R
I
C
A
L
ON
E
-
L
I
N
E
D
I
A
G
R
A
M
NO
S
C
A
L
E
PANEL:L1C (EXISTING)VOLTAGE:120/208V, 3PH, 4W MINIMUM BUS:225 LOCATION:MAIN:MOUNTING:MINIMUM AIC:NO.LOADTYPELOAD DESCRIPTIONBREAKERBUSBREAKERTYPELOAD DESCRIPTIONLOADNO.ABCPOLETRIPABCTRIPPOLEABC 1L-EXT PORTECOUCHRE+SPARE2 3L-EXT ISLAND BOLLARDS+SPARE4 5L-EXISTING LOAD+SPARE6 7L-WAITING AREA SPOTS+BATH SMOKE DAMPERS8 9L-PT LOCKER ROOM+R-ADMISSIONS10 11L-PT LOCKER ROOM+R-ADMISSIONS12 13R-ADMISSIONS+R-BATHROOM14 15R-LOBBY OFFICES+R-IGN. AND S. SIDE16 17R-BATHROOM+R-PT STAFF OFFICE18 19R-OFFICE/LOBBY+PANEL L1C120 21R-PT AC GFCI+PANEL L1C122 23R-PT STAFF OFFICE+PANEL L1C124 25R-MAIN LOBBY+PT HEATER26 27L-EXTERIOR+PT HEATER28 29R-PT S. WALL/H2O COOLER+R-RECEPTION DESK30 31R-PT S. OFFICE+R-VOLUNTEER DESK32 33R-PT S.WALL+402PARKING LOT PANEL SUBFEED3435R-VOLUNTEER DESK SP.+36 37AUTO DOOR+L-SOUTH WALK BOLLARD38 39AUTO DOOR+L-WEST WALL PHOTOCELL40 41AUTO DOOR+SPARE42 LOAD TYPEPANEL TOTALFEED THRUTOTALSUBFEEDTOTALFEEDERSUBTOTALDEMANDFEEDER TOTALGENERAL NOTES:A.(L) LIGHTING00125%0B.(R) RECEPTACLES00NEC 2200C.(LM) LARGEST MOTOR0025%0D.(M) MOTORS (ALL)00100%0E.(E) EQUIPMENT00100%0SPECIFIC NOTES:(A) APPLIANCES0000(1)PANEL TOTAL (KVA):0.0(2)(3)PANEL TOTAL (A):0(4)(5)PANEL:L1E (NEW)VOLTAGE:120/208V, 1PH, 3W MINIMUM BUS:100 LOCATION:PARKING LOTMAIN:MLO MOUNTING:MINIMUM AIC:NO.LOADTYPELOAD DESCRIPTIONBREAKERBUSBREAKERTYPELOAD DESCRIPTIONLOADNO.ABPOLETRIPABTRIPPOLEAB 11832LPARKING LOT LIGHTING EAST225+201LPARKING LOT LIGHTING WEST1145231832L+L11454 5+6 7+8 LOAD TYPEPANEL TOTALFEED THRU TOTALSUBFEEDTOTALFEEDERSUBTOTALDEMANDFEEDER TOTALGENERAL NOTES:A.(L) LIGHTING59545954125%7443B.(R) RECEPTACLES00NEC 2200C.(LM) LRG. MOTOR0025%0D.(M) MOTORS (ALL)00100%0E.(E) EQUIPMENT00100%0SPECIFIC NOTES:(A) APPLIANCES0000(1)PANEL TOTAL (KVA):7.4(2)(3)PANEL TOTAL (A):36(4)(5)SHEET TITLE:VAIL, COLORADO VAIL VALLEY MEDICAL CENTER - PARKING LOT LIGHTINGEAUDINANZECOPYRIGHT 2010 BG Vail:Denver:Fort Collins:Albuquerque:www.bgce.com(970)949-6108 (303) 278-3820 (970) 221-5691 (505) 323-9070 E2ELECTRICALONE-LINE DIAGRAM