HomeMy WebLinkAboutB12-0374 permit issuedMarch 25, 2013
Mr. Brennen Fitzgrald `
Scott S. Turnipseed, AIA
1143 Capitol St., Suite 211
Eagle, CO 81631
RE: New Duplex
4017 Lupine Dr.
Vail, Colorado
Dear Brennen:
` 612 Y
NEWKIRK ENGINEERING
6 Consulting Structural Engineering
410 River View Dr. #306
New Castle, Colorado 81647
970424 -1456
During my visit to the referenced site on 3/25/13 the following items were noted as requiring correction
or completion:
Item #1: In Unit A, on the main level in the south wall of the stairwell, between the stair and
Laundry Room, the stud pack indicated by keynote #5 is missing.
Item #2: In Unit A, on the main level in the southwest corner of the Great Room, the stud pack
indicated by keynote #5 is missing.
Item #3:. In Unit A, on the main level in the west wall of the Master Bath, the fourth stud pack
y` indicated by keynote #5 north of the southwest corner is missing.
Item #4: Ita Unit A, on the main level at the south side of the Great Room, at the northwest
corner of the Pantry, the stud pack indicated by keynote #7 is missing.
Item #5: In Unit A, on the main level in the east wall of the Laundry Room, the stud pack
indicated by keynote #7 is missing.
Item 46: In Unit A, on the main level at the Covered Entry, the two stud packs indicated by
keynote #5 in the exterior wall on either side of the front door are missing.
Item 47: In Unit A, on the main level in the Study Bath, the stud pack indicated by keynote #7
in the southeast corner is missing.
Item #8: In Unit A, on the main level in the southwest corner of the Butler's Pantry, the stud
park indicated by keynote #5 is missing.
Item #9: In Unit A, on the main level in the west wall of the Mechanical Room, the two stud
packs indicated by keynote #5 are missing.
Item #10: In Unit A, on the main level in the south wall of the Powder Room, the stud pack
indicated by keynote #7 is missing.
Item #11: In Unit A, on the upper level in the west wall of Bedroom #3, the southern of the two
stud packs indicated by keynote #8 is missing.
Item #12: In Unit B, on the main level in the west wall of the Powder Room, the stud pack
indicated by keynote #25, in the southwest corner, is missing.
Item #13: In Unit B, on the main level in Dining Room, the south wall has been framed with a
bay window and is adequate as constructed.
Mr. Brennen Fitzgerald
March 28, 2013
Page 2
Please forward this letter to the project superintendent after your review.
Sincerely:
NEWKIRK ENGINEERf NG
V2387S
Paul Newkirk. P.E.
Principal
NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES
MWNQFVA[I.;
Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657
p. 970.479.2139, f. 970.479.2452, inpsections 970.479.2149
COMBINATION BLDG PERMIT Permit #: B12 -0374
Job Address: 4017 LUPINE DR VAIL
Location......: UNIT B / EAST / SECONDARY
Parcel No....: 210112219004
1WNER TRUSCHEIT, ROBERT E. 08/17/2012
2338 HEARTH DR 39
EVERGREEN
CO 80439
ONTRACTOR SAMELSON BIGHORN LOT 7 LLC 08/23/2012
SAMELSON DEV CORP, LES SAMELSON PRESIDENT
PO BOX 418
VAI L
CO 81658
License: C000003600
Project #: PRJ11 -0709
Applied.....: 08/17/2012
Issued...: 09/12/2012
Phone: 970 - 376 -0076
RCHITECT SCOTT TURNIPSEED, AIA 08/17/2012 Phone: 970 - 328 -3900
1143 CAPITOL STREET, SUITE 211
PO BOX 3388
EAGLE
CO 81631
License: C000001848
PPLICANT TRUSCHEIT, ROBERT E. 08117/2012
2338 HEARTH DR 39
EVERGREEN
CO 80439
escription:
EW SFR UNIT B / EAST / SECONDARY
Occupancy: Type Construction:
Valuation: $651,000.00
. », «..»..,.,......,� »...,..»«..«..,..««...««.»» ..........««..».« » «»«««»«»« ««»« FEE SUMMARY ••«.»«««.«»««..... *
jilding Permit -->
$3,951.00
Bldg Plan Check - ->
$2,568.15
Use Tax Fee– -->
$12,820.00
ectrical Permit - >
$494.50
Elec Plan Check - - - ->
$321.43
Restuarant Plan Review - ->
$0.00
echanical Permit —>
$300.00
Mech Plan Check - - - ->
$75.00
Additional Fees >
$0.00
umbing Permit - ->
$360.00
Plmb Plan Check - - ->
$90.00
Recreation Fee - --->
$653.40
Investigation —>
$0.00
Will Call -- >
$20.00
TOTAL PERMIT FEES --- –>
$21,653.48
Payments - -- —>
$21,653.48
BALANCE DUE -- ->
$0.00
DECLARATIONS
agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure
;cording to the town's zoning and subdivision codes, design review approved, International Building and Residential Codes and
:her ordinances of the Town applicable thereto.
EQUESTS FOR INSPECTION SHALL BE MADE TWENTY -FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149
R AT OUR OFFICE FROM 8:00 AM - 4:00 PM.
-mbination permit - 012811
EM
CONDITIONS OF APPROVAL TO BE MET PRIOR TO FINAL SIGN OFF
Permit #: B12 -0374
Owner: TRUSCHEIT, ROBERT E.
NIT B / EAST / SECONDARY
Address: 4017 LUPINE DR VAIL
ond: CON0012786
Exterior light fixtures shall comply with Town of Vail
lutdoor Lighting Regulations, with after market sheild
stalled in sconces to be fully cut off to comply with
own of Vail Outdoor Lighting Regulations.
ond: 50
=IRE): FIRE SPRINKLER SYSTEM REQUIRED AND SHALL COMPLY
JITH NFPA 13R(2007) AND VFES STANDARDS.
ond: 51
=IRE 2007): MONITORED FIRE ALARM SYSTEM REQUIRED AND SHALL
OMPLY WITH NFPA 72(2007) AND VFES STANDARDS.
nbination permit-012811
Location:
OVAIUL
DWN
REQUIRED INSPECTIONS AND STATUSES
Permit #: B12 -0374
Owner: TRUSCHEIT, ROBERT E.
NIT B / EAST / SECONDARY
Address: 4017 LUPINE DR VAIL
Location:
em: 00090 BLDG -Final
)mbination permit-012811
NEWKIRK ENGINEERING
Consulting Strmcxural Engineering
410 River Bend Dr._ 4306
New Castle, CO 81647
210- 380 -1837
October 29, 2012
Mr. Les Samelson
Samelson Bighorn Lot 7 LLC
Re: New Duplex
4017 Lupine Dr_, Units A & B
Vail, CO
f.
I have no requirements on the structural drawings that I prepared for this project regarding special
inspection for soil compaction_ Also, the concrete compressive strength that I require on sheet S2.1 is
3,000 psi for footings, walls and slabs on grade. I understand that you have elected to use 4,000 psi for
serviceability for the slabs on grade_ The slabs on grade, as well as footings and foundation walls, do not
therefore require special kapection
Please let me know if you have any questions or if I may be of future assistanee.
Sincerely:
West Slope Testing & Inspection LLC
3177 Glendatn Dr.
Grand Junction, CO 81504
Phone: 970 - 434 -6988
Cell: 970 -260 -2844
Final
Date: 2 -18-13
In
Client: HP Geotech (Job #HP 111344A)
Project: Lupine Duplex
Address: 4017 Lupine Dr. Vail, CO
Building Permit No: Al2 -0376 & B12 -0374
General Contractor: Samelson Development
Inspection of shop fabrication or field work at job site:
Report #2
Page 1 of 1
& Field
Report: Visually inspected welding & bolting at wood team nucxers, and wumwt
at connections of buckets to tops of steel columns roof level framing both units.
The welding & bolting inspected. as outlined above appeared to be in substantial
conformance with the plans, and the quality requirements of the AWS D1.1
Structural Welding Code.
To the best of my knowledge this completes the special inspections of the
structural steel welding, high strength bolting, and steel frame details as outlined
in reports #1 & #2 for the project.
JE YInspector/Technician: Douglas E Young 1 1 1 '711201
West Slope Testing & Inspection LLC
3177 Glendam Dr.
Grand Junction, CO 81504
Phone: 970- 434 -6988
Cell: 970 -260 -2844
n Report
Date: 12 -20-12
Client: HP Geotech (Job #B P 111 344A)
Project: Lupine Duplex
Address: 4017 Lupine Dr. Vail, CO
Building Permit No: Al2 -0376 & B12 -0374
General Contractor: Samelson Development
Inspection of shop fabrication or field work at job site:
Report #1
Page 1 of 1
& Field
Report: Visually inspected welding, and verified materials, details, and bolting at
steel columns (base & bucket connections) main to upper floor framing.
The welding, bolting, and steel frame details inspected as outlined above
appeared to be in substantial conformance with the plans, and the quality
requirements of the AWS D1.1 Structural Welding Code.
The roof level steel (welding/bolting) will need to be inspected at a later date
when completed
Inspector/Technician: Douglas E Young �l 14
L .
March 19, 2013
Mr. Les Samelson
Samelson Bighorn Lot 7 LLC
Re: New Duplex
4017 Lupine Dr., Units A & B
Vail, CO
Dear Les:
v / % / '
U,1"& L Dr
NEWKIRK ENGINEERING
Consulting Structural Engineering
410 River Bend Dr., #306
New Castle, CO 81647
970 - 424 -1456
612 -O S7 �
13,-L -�3Z�-
I have reviewed the steel column base plate grouting for the interior column bases that will be incased in
concrete closure pours and have found the grout installation to be satisfactory.
Please let me know if you have any questions or if I may be of further assistance.
Sincerely:
NEWKIRK ENGINEERING
Paul H. Newkirk, PE
Principal
-7. -, -:.
West Slope Testing & hmpection LLC Report #1
3177 Glendam Dr.
Grand Junction, CO 81504 Page 1 of 1
Phone: 970- 434 -6988
Cell: 970 - 260 -2844
Inspection Report
Date: 12 -20-12
Client: I3P Geotech (Job #BP 111 344A) /
Project: Lupine Duplex
Address: 4017 Lupine Dr. Vail, CO _- ✓�
Building Permit No: Al2 -0376 B12 -0374
General Contractor: Samelson Development
Inspection of shop fabrication or field work at 'ob site: S op field
Report: Visually inspected welding, and verified materials, , and bolting at
steel columns (base & bucket connections) main to upper floor framing.
The welding, bolting, and steel frame details inspected as outlined above
appeared to be in substantial conformance with the plans, and the quality
requirements of the AWS D1.1 Strucbnal Welding Code.
The roof level steel (welding/bolting) will need to be inspected at a later date
when completed.
Inspector/Technician: Douglas E Youngr� j 14
�= Gmail - Inspection Report #1 for Job No. 111 344A (4017 Lupine Drive) Page 1 of 1
Les Samelson< lessamelson@gmail.com>
Inspection Report #1 for Job No. 111 344A (4017 Lupine Drive)
1 message
Lena Galliher< lenag @hpgeotech.com> Fri, Dec 28, 2012 at 3:25 PM
To: Les Samelson <LesSamelson @gmail.com>
Cc: Scott Tumipseed <scott @sstaia.com>
Please see attached report.
If you have any questions please give us a call.
Thank you,
Lena
Lena Galliher
Administrative Assistant
5020 County Road 154
Glenwood Springs, co 81601
,v Report #1.pdf
22K
httns: // mail.e ooele .com /maill?ui= 2 &ik= 5affcOf282& view= vt&search= inbox &th= 13be39... 12/28/2012
West Slope Testing & Inspection LLC Report ##2
3177 Glendam Dr.
Grand Junction, CO 81504 Page 1 of 1
Phone: 970- 434 -6988
Cell: 970 -260 -2844
Final Insuection Report
Date: 2- 18-13
Client: BP Geotech (Job #HP 111344A)
Project: Lupine Duplex
Address: 4017 Lupine Dr. Vail, CO \ I
Building Permit No: Al2 -0376 & B12 -0374
General Contractor: Samelson Development
Inspection of shop fabrication or field work at job site: Shop Field
Report: Visually inspected welding & bolting at wood beam buckets, and welding
at connections of buckets to tops of steel columns roof level framing both units.
The welding & bolting inspected as outlined above appeared to be in substantial
conformance with the plans, and the quality requirements of the AWS D 1.1
Structural Welding Code.
To the best of my knowledge this completes the special inspections of the
structural steel welding, high strength bolting, and steel frame details as outlined
in reports #1 & #2 for the project.
Inspector/Technician: Douglas E Young 17-71141201 ot
*4i
it - Steel Inspection for 4017 Lupine Drive (Job No. 111 344A) Page 1 of 1
Les Samelson < lessamelson@gmail.com>
A.
Steel Inspection for 4017 Lupine Drive (Job No. 111 344A)
1 message
Lena Galliher < lenag@hpgeotech.com> Fri, Mar 29, 2013 at 9:22 AM
To: Les Samelson <LesSamelson @gmail.com>
Please see attached report.
If you have any questions please give us a call.
Thank you,
Lena
Lena Galliher
Administrative Assistant
ienag @hpgeotech.con'�
5020 County Road 154
Glenwood Springs, Co 81601
Report #2.pcif
23K
https:llmail. google.comlmaill ?ui= 2 &ik =5 affcOf282 &view=pt&search= inbox &th =13 db6be... 3/29/2013
i
NEWKIRK ENGINEERING
Consulting Structural Engineering
410 River Bend Dr., #306
New Castle, CO 81647
970 - 424 -1456
March 19, 2013
Mr. Les Samelson
Samelson Bighorn Lot 7 LLC
Re: New Duplex
4017 Lupine Dr., Units A & B
Vail, CO
Dear Les:
I have reviewed the steel column base plate grouting for the interior column bases that will be incased in
concrete closure pours and have found the grout installation to be satisfactory.
Please let me know if you have any questions or if I may be of further assistance.
Sincerely:
NEWKIRK ENGINEERING
Paul H. Newkirk, PE
Principal
Gmail - Photo steel 4017 lupine Page 1 of 1
Les Samelson < lessamelsonfgmail.com>
Photo steel 4017 lupine
2 messages
Les Samelson < lessamelson @gmail.com> Tue, Mar 19, 2013 at 10:35 AM
To: Paul Newkirk <newkirk56 @gmail.com>
Sent from my iPhone
photo.JPG
427K
Paul Newkirk < newkirk56 @gmail.com> Tue, Mar 19, 2013 at 12:24 PM
To: Les Samelson <lessamelson@gmail.com>
Cc: Brennen Fitzgerald <brennen @sstaia.com>
Les:
Attached is the letter for the base plate grouting.
Paul
On Tue, Mar 19, 2013 at 10:35 AM, Les Samelson <9essarneisonCaymais oor > wrote:
Sent from my iPhone
�g 4017 Lupine -2.doc
334K
httvs: // mail. google .com /maill?ui= 2 &ik= 5affcOf282 &view= pt&search= inbox &th =13d83 82... 3/19/2013
NEWKIRK ENGINEERING
Consulting Structural Engineering
410 River Bend Dr_ #306
New Castle, CO 81647
210- 380 -1837
October 29, 2012
Mr. Les Samelson
Samelson Bighorn Lot 7 LLC
Re: New Duplex
4017 Lupine Dr., Units A & B
Vail, CO
I have no requirements on the structural drawings that I prepared for this project regarding special
inspection for soil compaction. Also, the concrete compressive strength that I require on sheet S2.1 is
3,000 psi for footings, walls and slabs on grade_ I understand that you have elected to use 4,000 psi for
serviceability for the slabs on grade. The slabs on grade, as well as footings and foundation walls, do not
therefore require special inspection
Please let me know if you have any questions or if I may be of future assistance.
Sincerely:
-tom CO
1
12 -16 -2013 inspection Request Reporting � Page 11
4733 pm Veil CO - Oi p
Requested Inspect Date: Tuesda December 17, 2013
Site Address: 4017 IT ETAS T/ SECONDARY
A /P /D Information
Activity: B12 -0374 Type: COMBO
Const Type: Occupancy:
Owner: TRUSCHEIT, ROBERT E.
Contractor: SAMELSON BIGHORN LOT 7 LLC
Architect: SCOTT TURNIPSEED, AIA
Description: NEW SFR UNIT B / EAST / SECONDARY
Re uested Ins e ' n s
.1 em: 91 PW -Final driveway grade
Regd estor:
Comments: 376 -0076
Assigned To: JMONDRAGON
,Action: a Exp:
Item: 90 BLDG -Final
Requestor:
Comments: 376 -0076
Assigned To: SG MER
Action: Time Exp:
Sub Type: ASFR
Use:
Phone: 970- 376 -0076
Phone: 970- 328 -3900
Status: ISSUED
Insp Area:
Requested Time: 08:00 AM
Phone:
Entered By: MHAEBERLE K
Requested Time: 01:00 PM
Phone:
Entered By: MHAEBERLE K
Item: 290 PLMB -Final Requested Time: 02:30 PM
Requestor: Phone:
Comments: 376-007,6 Entered By: MHAEBERLE K
Assigned To: SG ER
Action: Time Exp:
Comment: R CONDENSATE DRAIN- REQUIRED
Item:
310 MECH- Heating
Requested Time:
Phone:
03:00 PM
Requestor:
Comments:
Assigned To:
376 -0076
SG REM R
Entered By:
MHAEBERLE K
Time Exp:
P
Item:
390 MECH -Final
Requested Time:
Phone:
02:00 PM
Requestor:
Comments:
Assigned To:
376 -0076
SG R
Entered By:
MHAEBERLE K
Action:
Comment:
Time Exp:
BE EXTENDED 361NZHE�ABOVE ROOF LOCAL AMENDMENT.
KIT EN EXHAUST NOT READY
�U4 vu—)
Inspection History
Item: 90 BLDG -Final
Item: 10 BLDG - FOOTING **Approved**
10/03/12 Inspector: sgremmer Action: AP APPROVED
REPT131 Run Id: 14658