Loading...
HomeMy WebLinkAboutB12-0210 - REV1 - 090412 corrections requiredSCALE PROJECT NUMBER DRAWN BY CHECKED BY COPYRIGHT 2012 1DRC PRELIM. REVIEW05.12.11 2BID SET06.15.11 3T.O.V. PERMIT SET05.24.12 4T.O.V. INT. PERMIT SET08.30.12 12" = 1'-0" 1476 WESTHAVEN DR. UNIT #3(COLDSTREAM) VAIL, CO 81657PARCEL #210312108003ACCOUNT #R013068 A1.00 COVER SHEET 0611 KOELBEL RESIDENCE INTERIOR ALTERATION ML ML T.O.V. INTERIOR PERMIT SUBMITTAL 08.30.12 DRAWING INDEX GENERAL A1.00 COVER SHEET A1.01 GENERAL NOTES ARCHITECTURAL A2.00 SECOND FLOOR DEMO PLAN A2.01 SECOND FLOOR PLAN A2.02 THIRD FLOOR DEMO PLAN A2.03 THIRD FLOOR PLAN A2.04 SECOND FLOOR LIGHTING & ELECTRICAL PLAN A2.05 THIRD FLOOR LIGHTING & ELECTRICAL PLAN VICINITY MAP GRAPHIC SCALE = 150' PROJECT NARRATIVE THE PROPOSED INTERIOR RENOVATION INCLUDES THE FOLLOWING: 1.RECONFIGURED INTERIOR WALLS. 2.NEW FINISHED FLOORINGS. 3.NEW FIXED FINISHES. 4.NEW BATHROOM FIXTURES. 5.NEW KITCHEN FIXTURES & APPLIANCES. 6.NEW CABINETRY & COUNTERTOPS. 7.NEW LIGHTING. 8.NEW BUILT-IN CABINETRY PROJECT DIRECTORY OWNER ELDORADO REALTY CO 5291 E. YALE AVE DENVER, CO 80222 303.662.0657 P ROBERT KOELBEL BOB@KOELBELHOMES.COM GENERAL CONTRACTOR MINICK CONSTRUCTION PO BOX 4018 VAIL, CO 81658 T.O.V. CONSTRUCTION LICENSE #24B 970.904.5066 P DAVE MINICK DKMINICK@YAHOO.COM ARCHITECT 8150 ARCHITECTS LLC PO BOX 3604 VAIL, CO 81658 970.376.3326 P 888.879.2105 F MATT LEE AIA, LEED AP MATT@8150ARCHITECTS.COM UNIT #3 WE S T H A V E N D R GORE CREEK COLDSTREAM NO.DESCRIPTIONDATE RECEIV VED 09/04/12 A101 1 SIM 101 Room name 101 1 A101 SIM 1i 1t 1 1A101 SIM SECTION ELEVATION DETAIL/ENLARGED PLAN GRID REVISION 0 NORTH ARROW ELEVATION WALL TAG WINDOW TAG DOOR TAG ROOM TAG NameElevation ROOM NAME SCALE PROJECT NUMBER DRAWN BY CHECKED BY COPYRIGHT 2012 1DRC PRELIM. REVIEW05.12.11 2BID SET06.15.11 3T.O.V. PERMIT SET05.24.12 4T.O.V. INT. PERMIT SET08.30.12 As indicated 1476 WESTHAVEN DR. UNIT #3(COLDSTREAM) VAIL, CO 81657PARCEL #210312108003ACCOUNT #R013068 A1.01 GENERAL NOTES 0611 KOELBEL RESIDENCE INTERIOR ALTERATION ML ML T.O.V. INTERIOR PERMIT SUBMITTAL 08.30.12 GENERAL NOTES 1. THE AIA DOCUMENT A105, STANDARD FORM OF AGREEMENT BETWEEN OWNER AND CONTRACTOR FOR A RESIDENTIAL OR SMALL COMMERCIAL PROJECT, 2007 EDITION, IS HEREBY MADE A PART OF THESE CONTRACT DOCUMENTS. COPIES ARE INCLUDED IN THE PROJECT MANUAL AND ARE AVAILABLE FOR INSPECTION AT THE OFFICES OF THE ARCHITECT. 2. THE CONTRACT DOCUMENTS CONSIST OF THE GENERAL CONDITIONS OF THE CONTRACT FOR CONSTRUCTION, THE GENERAL NOTES, THE SPECIFICATIONS, AND THE DRAWINGS, WHICH ARE COOPERATIVE AND CONTINUOUS. WORK INDICATED OR REASONABLY IMPLIED IN ANY ONE OF THE DOCUMENTS SHALL BE SUPPLIED AS THOUGH FULLY COVERED IN ALL. ANY DISCREPANCY BETWEEN THE DIFFERENT PARTS SHOULD BE REPORTED TO THE ARCHITECT IMMEDIATELY.3. ALL WORK SHALL COMPLY WITH ALL STATE AND LOCAL CODES AND ORDINANCES, THE CONTRACTOR SHALL BE RESPONSIBLE FOR SATISFYING ALL APPLICABLE CODES AND OBTAINING ALL PERMITS AND REQUIREDAPPROVALS.4. IT IS THE INTENT AND MEANING OF THESE DOCUMENTS THAT THE CONTRACTOR AND EACH SUBCONTRACTOR PROVIDE ALL LABOR, MATERIALS, TRANSPORTATION, SUPPLIES, EQUIPMENT, ETC. TO OBTAIN A COMPLETE JOBWITHIN THE RECOGNIZED STANDARDS OF THE INDUSTRY. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO BRING TO THE ATTENTION OF THE ARCHITECT ANY CONDITIONS WHICH WILL NOT PERMIT CONSTRUCTIONACCORDING TO THE INTENTIONS OF THESE DOCUMENTS. IT IS THE RESPONSIBILITY OF THE ARCHITECT TO PROVIDE DETAILS AND/OR DIRECTIONS REGARDING DESIGN INTENT WHERE IT IS ALTERED BY EXISTING CONDITIONSOR WHERE NEGLECTED IN THE DOCUMENTS. IN THE EVENT THAT ADDITIONAL DETAILS OR GUIDANCE IS NEEDED BY THE CONTRACTOR FOR CONSTRUCTION OF ANY ASPECTS OF THIS PROJECT, THE CONTRACTOR SHALLIMMEDIATELY NOTIFY THE ARCHITECT.5. VERIFY ALL DIMENSIONS, EXISTING CONDITIONS AND UTILITY LOCATIONS ON THE JOB SITE PRIOR TO BEGINNING ANY WORK OR ORDERING ANY MATERIALS.6. NOTIFY ARCHITECT OF ANY CONFLICTS OR DISCREPANCIES IN THE DOCUMENTS IMMEDIATELY. AREAS OF CONFLICTS OR DISCREPANCIES MUST BE FULLY RESOLVED WITH WRITTEN APPROVAL FROM THE ARCHITECTBEFORE CONSTRUCTION CONTINUES IN THOSE AREAS. 7. CONTRACTOR TO SUMBIT CUT SHEETS/SPECIFICATIONS AND SAMPLES* OF ALL PRODUCTS & MATERIALS FOR ARCHITECT'S APPROVAL PRIOR TO ORDERING PRODUCTS & MATERIALS. *SOME PRODUCTS MAY NOT REQUIRE A SAMPLE TO BE SUBMITTED (COORDINATE W/ ARCHITECT). 8. ANY MATERIALS PROPOSED FOR SUBSTITUTION OF THOSE SPECIFIED OR CALLED OUT BY TRADE NAME IN THESE DOCUMENTS SHALL BE PRESENTED TO THE ARCHITECT FOR REVIEW. THE CONTRACTOR SHALL SUBMIT SAMPLES WHEN REQUIRED BY THE ARCHITECT AND ALL SUCH SAMPLES SHALL BE REVIEWED BY THE ARCHITECT BEFORE THE WORK IS PERFORMED. WORK MUST CONFORM TO THE REVIEWED SAMPLES. ANY WORK WHICH DOES NOT CONFORM SHALL BE REMOVED AND REPLACED WITH WORK WHICH CONFORMS AT THE CONTRACTOR'S EXPENSE. SUBCONTRACTORS SHALL SUBMIT REQUESTS AND SAMPLES FOR REVIEW THROUGH THE GENERAL CONTRACTOR WHEN WORK IS LET THROUGH HIM OR HER. REQUIRED VERIFICATIONS AND SUBMITTALS TO BE MADE IN ADEQUATE TIME AS NOT TO DELAY WORK IN PROGRESS.9. SHOP DRAWINGS SHALL BE SUBMITTED TO THE ARCHITECT FOR HIS OR HER REVIEW WHERE CALLED FOR ANYWHERE IN THESE DOCUMENTS. REVIEW SHALL BE MADE BY THE ARCHITECT BEFORE WORK IS BEGUN, ANDWORK SHALL CONFORM TO THE REVIEWED SHOP DRAWINGS, SUBJECT TO REPLACEMENT AS REQUIRED IN PARAGRAPH 8, ABOVE.10. THE BUILDING INSPECTOR SHALL BE NOTIFIED BY THE CONTRACTOR WHEN THERE IS NEED OF INSPECTION AS REQUIRED BY THE INTERNATIONAL RESIDENTIAL CODE, THE INTERNATIONAL BUILDING CODE OR ANY LOCALCODE OR ORDINANCE.11. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE SAFETY AND CARE OF ADJACENT PROPERTIES DURING CONSTRUCTION, FOR COMPLIANCE WITH FEDERAL AND STATE O.S.H.A. REGULATIONS, AND FOR THEPROTECTION OF ALL WORK UNTIL IT IS DELIVERED COMPLETED TO THE OWNER.12. DO NOT SCALE DRAWINGS. ALL DIMENSIONS NOTED TAKE PRECEDENCE OVER SCALED DIMENSIONS. DIMENSIONS NOTED WITH "N.T.S." DENOTES NOT TO SCALE.13. PLAN DIMENSIONS ARE TO FACE OF STUD/STRUCTURE, FACE OF COLUMN OR FACE OF CONCRETE UNLESS OTHERWISE NOTED. SECTION AND ELEVATION DIMENSIONS ARE TO FACE OF STUD/STRUCTUR, FACE OF COLUMN,FACE OF CONCRETE, TOP OF CONCRETE, TOP OF PLYWOOD, TOP OF WALL PLATES OR TOP OF BEAMS UNLESS OTHERWISE NOTED.14. THE CONTRACTOR SHALL VERIFY ALL EXISTING GRADES AND STAKE OUT PROPOSED WORK FOR OWNER AND ARCHITECT APPROVAL PRIOR TO BEGINNING ANY SITE WORK. 15. CONTRACTOR SHALL VERIFY AND COORDINATE ALL OPENINGS THROUGH FLOORS, CEILINGS, AND WALLS WITH ALL ARCHITECTURAL, STRUCTURAL, MECHANICAL, PLUMBING, AND ELECTRICAL DRAWINGS. THE CONTRACTOR SHALL FIELD COORDINATE AND OBTAIN APPROVAL FROM THE ARCHITECT & ENGINEER BEFORE ANY CUTTING, NOTCHING OR DRILLING OF ANY CAST-IN-PLACE CONCRETE, STEEL FRAMING, OR ANY OTHER STRUCTURAL ELEMENTS WHICH MAY AFFECT THE STRUCTURAL INTEGRITY OF THE BUILDING. 16. COORDINATE ALL ELECTRICAL AND MECHANICAL FIXTURES TO FIT WITHIN CEILING, FLOOR AND WALLS SPACES. VERIFY LOCATIONS WITH ARCHITECT.17. PROVIDE ALL NECESSARY BLOCKING IN STUD WALLS AND CEILINGS. LOCATIONS INCLUDE BUT ARE NOT LIMITED TO CEILING AND WALL MOUNTED FIXTURES, TOILETS, TOILET ACCESSORIES, GRAB BARS, CABINETRY,COUNTERTOPS, SHELVES AND CLOSET RODS.18. CONTRACTOR WILL ASSUME RESPONSIBILITY OF ITEMS REQUIRING COORDINATION AND RESOLUTION DURING THE BIDDING PROCESS. BIDDING NOTES 1. DRAWINGS OF EXISTING CONDITIONS ARE BASED OFF OF ROUGH FIELD SURVEYS. ALL LOCATIONS, DIMENSIONS, AREAS, SCHEDULES, QUANTITIES & MATERIAL TAKEOFFS OF EXISTING CONDITIONS GIVEN ARE FORREPRESENTING THE SCOPE OF THE WORK & GENERAL ORDER OF MAGNITUDE ESTIMATING. THEY ARE NOT TO BE RELIED UPON FOR ACCURATE BID ESTIMATING. IT IS THE RESPONSIBLITY OF THE CONTRACTOR TO FIELDVERIFY ALL LOCATIONS, DIMENSIONS, AREAS, SCHEDULES, QUANTITIES & MATERIAL TAKEOFFS PRIOR TO SUBMITTING HIS/HER BID.2. CONTRACTOR TO INCLUDE ALL ASSOCIATED COSTS (EXCEPT FOR BUILDING PERMITS & SIMILAR FEES) TO PERFORM THE WORK INCLUDING BUT NOT LIMITED TO: DEMOLITION, HAUL & DUMP FEES, SITE FENCING, BUILDING PROTECTION, OFF & ON-SITE MATERIAL STORAGE. 3. CONTRACTOR TO PROVIDE EVIDENCE OF INSURANCE. CONTRACTOR & SUBCONTRACTORS TO NAME OWNER AS "ADDITIONALLY INSURED" FOR THE DURATION OF THE WORK. ABBREVIATIONS ABV ABOVEAFFABOVE FINISHED FLOORAPACCESS PANELACACOUSTICALADAAGADA ACCESSIBILITY GUIDELINESADDADDENDUM ADJ ADJACENT ALT ALTERNATE ALUM ALUMINUM AIA AMERICAN INSTITUTE OF ARCHITECTSANSIAMERICAN NATIONAL STANDARDS INSTITUTEASTMAMERICAN SOCIETY FOR TESTING & MATERIALSADAAMERICANS WITH DISABILITIESARCHARCHITECT(URAL)ASI ARCHITECT’S SUPPLEMENTAL INSTRUCTIONSABAARCHITECTURAL BARRIERS ACTAHJAUTHORITY HAVING JURISDICTIONBASMTBASEMENTBRGBEARINGBVLBEVELEDBITBITUMINUOUS BLK BLOCK BLKG BLOCKING BOT BOTTOM BLDG BUILDINGCPTCARPET(ED)CSMT CASEMENTCCAULK(ING)CLG CEILINGCENTERLINECTCERAMIC TILECLRCLEARCLCLOSETCOLCOLUMNCONCCONCRETE CMU CONCRETE MASONRY UNIT CONST CONSTRUCTION CSI CONSTRUCTION SPECIFICATIONS INSTITUTE CONT CONTINUOUS CJT CONTROL JOINT CPR COPPERCUSTCUSTOMDDEPTH, DEEP DTL DETAILDIMDIMENSIONDRDOORDSDOWNSPOUTDTDRAPERY TROUGH DWG DRAWING(S) DF DRINKING FOUNTAIN ELEC ELECTRIC(AL) ELEV ELEVATION(S)EL ELEVATORERVENERGY RECOVERY VENTILATOREQEQUALETCET CETERAEPDMETHYLENE PROPYLENE DIENE MONOMEREXHEXHAUSTEXISTEXISTINGEXTEXTERIORFOCFACE OF CONCRETE (COLUMN)FOF FACE OF FINISHFOMFACE OF MASONRY FOS FACE OF STRUCTURE (STUD(S)) FIN FINISH(ED) FFE FINISHED FLOOR ELEVATION FE FIRE EXTINGUISHER FDC FIRE DEPARTMENT CONNECTIONFHCFIRE HOSE CONNECTIONFECFIRE EXTINGUISHER CABINETFPLFIREPLACEFPFIREPROOFINGFLGFLASHINGFLRFLOOR(ING)FD FLOOR DRAINFTGFOOTINGFNDFOUNDATIONFBOFURNISHED BY OTHERS (OWNER) FPHB FREEZE PROOF HOSE BIB FURR FURRED, FURRING GA GAGE, GAUGE GV GALVANIZED GC GENERAL CONTRACT(OR)GL GLAZING, GLASSGSFGROSS SQUARE FOOTAGEGYPGYPSUM GWB GYPSUM WALL BOARDHBHOSE BIBHDWHARDWAREHDRHEADERHTGHEATING HVAC HEATING VENTILATING & AIR CONDITIONING HT HEAVY TIMBER, HEIGHT HC HOLLOW CORE HM HOLLOW METALHORHORIZONTALHWHHOT WATER HEATERINCLINCLUDE(D), INCULDINGIDINSIDE DIAMETERIBOINSTALLED BY OTHERS/OWNERINSINSULATE(D), INSULATIONINTINTERIORIBCINTERNATIONAL BUILDING CODE,INSTALLED BY CONTRACTORICCINTERNATIONAL CODE COUNCILIRCINTERNATIONAL RESIDENTIAL CODE JC JANITOR’S CLOSET KIT KITCHEN LAM LAMINATE(D) LAV LAVATORY LH LEFT HANDLLENGTHLDTLIGHT & DRAPERY TROUGHLTLIGHT, LIGHT TROUGHLTLLINTELLVRLOUVERMHMANHOLEMFRMANUFACTURE(D), MANUFACTURERMOMASONRY OPENINGMTLMATERIALMAXMAXIMUM MECH MECHANIC(AL) MEP MECHANICAL/ELECTRICAL/PLUMBING (ENG.) MC MEDICINE CABINET MB MEMBRANE MET METALMMETER(S)MM MILLIMETER(S)MIN MINIMUM MIR MIRRORMISCMISCELLANEOUSMULLMULLIONNFPANATIONAL FIRE PROTECTION ASSOCIATIONNATNATURAL NSF NET SQUARE FOOTAGE NLSF NET LEASABLE SQUARE FOOTAGE NOM NOMINAL N/A NOT APPLICABLENICNOT IN CONTRACTNRNOT-RATED, NOISE REDUCTIONNTSNOT TO SCALEOCON CENTEROPGOPENINGOPPOPPOSITEOPHOPPOSITE HANDOHOVERHEADPRPAIRPKPARKINGPVMTPAVEMENT PL PLASTIC LAMINATE, PLATE, PROPERTY LINE PT POINT, PRESSURE TREATED PSF POUNDS PER SQUARE FOOT PSI POUNDS PER SQUARE INCH QT QUARRY TILERECRECOMMENDATION(S)RE REFER(ENCE)REFR REFRIGERATORREINFREINFORCE(D), REINFORCINGRFIREQUEST FOR INFORMATION/CLARIFICATIONREQ’D REQUIREDRESRESILIENTREVREVISION(S)REVS REVERSERHRIGHT HAND R RISER R&S ROD & SHELF RD ROOF DRAIN RDT RECESSED DRAPERY TRACK RFG ROOFINGRMROOMROROUGH OPENINGR/S ROUGH SAWN S SEALANTSHTGSHEATHINGSMSHEET METALSIMSIMILARSCSOLID CORE SPEC SPECIFICATION(S) SQ SQUARE SQ FT SQUARE FOOT(AGE) STD STANDARDSTSTAINSSSTAINLESS STEELSTLSTEELSDSTORM DRAINSTRUCT STRUCTURE, STRUCTURALTELTELEPHONETVTELEVISIONTHRTHRESHOLDT&M TIME & MATERIALST&G TONGUE & GROOVETOBTOP OF BEAM TOS TOP OF SLAB/STEEL/STRUCTURE TOW TOP OF WALL TB TOWEL BAR TR TRANSOM T TREADTSTUBE STEELTYPTYPICALULUNDERWRITERS LABORATORIESUFASUNIFORM FEDERAL ACCESSIBLITY STANDARDSUNOUNLESS NOTED OTHERWISEVBVAPOR BARRIERVIFVERIFY IN FIELDVERTVERTICALVCTVINYL COMPOSITION TILEWBWALL BOARD WC WATER CLOSET WP WATERPROOF(ING) WWF WELDED WIRE FABRIC W WIDTH, WIDE WDW WINDOWW/WITHW/O WITHOUTWDWOOD NO.DESCRIPTIONDATE RE L O C A T E D O O R T O NE W W A L L DE M O H E A R T H DE M O W A L L S DE M O G U A R D R A I L DE M O F I R E P L A C E & F L U E DI N I N G R O O M RE L O C A T E LI G H T FI X T U R E DE C K 1 LI V I N G R O O M ST A I R EN T R Y BA T H 1 BE D R O O M 1 CL 3 EL E C . P KI T C H E N CL 2 CL 1 1 4 3 A B C D E 2 SCALE PROJECT NUMBER DRAWN BY CHECKED BY COPYRIGHT 2012 1DRC PRELIM. REVIEW05.12.11 2BID SET06.15.11 3T.O.V. PERMIT SET05.24.12 4T.O.V. INT. PERMIT SET08.30.12 As indicated 1476 WESTHAVEN DR. UNIT #3(COLDSTREAM) VAIL, CO 81657PARCEL #210312108003ACCOUNT #R013068 A2.00 SECOND FLOOR DEMO PLAN 0611 KOELBEL RESIDENCE INTERIOR ALTERATION ML ML T.O.V. INTERIOR PERMIT SUBMITTAL 08.30.12 1 / 4 " = 1 ' - 0 " 1 SE C O N D F L O O R D E M O P L A N NO T E : O N L Y T H E I N T E R I O R SC O P E O F W O R K ( S H O W N AB O V E D A S H E D L I N E ) I S IN C L U D E D I N T H I S P E R M I T S E T NO T E : T H E E X T E R I O R S C O P E OF W O R K ( S H O W N B E L O W DA S H E D L I N E ) W A S I N C L U D E D IN T H E E X T E R I O R P E R M I T SE T D A T E D 0 5 . 2 4 . 1 2 ( P E R M I T # B 1 2 - 0 2 1 0 ) GE N E R A L N O T E S : 1. GR A Y H A T C H I N D I C A T E S E X I S T I N G W A L L S . 2. DA S H E D L I N E S I N D I C A T E D E M O L I S H E D / R E M O V E D . NO.DESCRIPTIONDATE DE M O W A L L S , D O O R S , ST A I R S , H A N D R A I L S , CA B I N E T S , F I X T U R E S & AP P L I A N C E S S H O W N DA S H E D NE W E X T E R I O R W A L L S RE L O C A T E D DO O R NE W I N T E R I O R WA L L . M A I N T A I N CH A S E F I R E R A T I N G NE W G U A R D R A I L DE C K 1 RE L O C A T E D LI G H T F I X T U R E KI T C H E N ST A I R EN T R Y BA T H 1 BE D R O O M 1 CL 3 NE W C U S T O M B U I L T - I N WA R D R O B E P E R O W N E R NEW CUSTOM BUILT-IN STORAGE PER OWNER NE W S K I R A C K P E R O W N E R TV PA N T R Y D/ W W/ D RE C O N S T R U C T W A L L S A S OP E N G U A R D R A I L S P E R OW N E R . C O M P L Y W / I R C R 3 1 2 TV NE W K I T C H E N CA B I N E T S , CO U N T E R T O P S , FI X T U R E S & AP P L I A N C E S P E R OW N E R . C O M P L Y W/ I R C R 3 0 6 EL E C . P OP T I O N : D E M O D W H & W A L L S . IN S T A L L E L E C T . T A N K L E S S DW H & T W O S I N K V A N I T Y DI N I N G R O O M LI V I N G R O O M 1 4 3 A B C D E 2 RE F . NE W C U S T O M CA B I N E T R Y F O R WA S H E R / D R Y E R , PA N T R Y & RE F R I G E R A T O R 3' - 4" NE W V A N I T Y , TO I L E T & S H O W E R PE R O W N E R . CO M P L Y W / I R C R3 0 6 & R 3 0 7 NE W I N T E R I O R D O O R S P E R OW N E R ( T Y P . ) TI L E C R P TILE CRP WOOD TILE CRP WOOD 32 " 30 " 30 " 24 " NE W H A N D R A I L . C O M P L Y W / IR C R 3 1 1 . 7 . 7 SCALE PROJECT NUMBER DRAWN BY CHECKED BY COPYRIGHT 2012 1 DRC PRELIM. REVIEW 05.12.11 2 BID SET 06.15.11 3 T.O.V. PERMIT SET 05.24.12 4 T.O.V. INT. PERMIT SET 08.30.12 As indicated 1476 WESTHAVEN DR. UNIT #3(COLDSTREAM) VAIL, CO 81657PARCEL #210312108003ACCOUNT #R013068 A2.01 SECOND FLOOR PLAN 0611 KOELBEL RESIDENCE INTERIOR ALTERATION ML ML T.O.V. INTERIOR PERMIT SUBMITTAL 08.30.12 1 / 4 " = 1 ' - 0 " 1 SE C O N D F L O O R P L A N GE N E R A L N O T E S : 1. GR A Y H A T C H I N D I C A T E S N E W W A L L S . NO T E : O N L Y T H E I N T E R I O R SC O P E O F W O R K ( S H O W N AB O V E D A S H E D L I N E ) I S IN C L U D E D I N T H I S P E R M I T S E T NO T E : T H E E X T E R I O R S C O P E OF W O R K ( S H O W N B E L O W DA S H E D L I N E ) W A S I N C L U D E D IN T H E E X T E R I O R P E R M I T SE T D A T E D 0 5 . 2 4 . 1 2 ( P E R M I T # B 1 2 - 0 2 1 0 ) NO.DESCRIPTION DATE ST A I R MA S T E R B A T H MA S T E R B E D R O O M DE C K 2 OP E N T O B E L O W OF F I C E MA S T E R C L O S E T 1 4 3 A B C D E 2 SCALE PROJECT NUMBER DRAWN BY CHECKED BY COPYRIGHT 2012 As indicated 1476 WESTHAVEN DR. UNIT #3(COLDSTREAM) VAIL, CO 81657PARCEL #210312108003ACCOUNT #R013068 A2.02 THRID FLOOR DEMO PLAN 0611 Author Checker KOELBEL RESIDENCE INTERIOR ALTERATION T.O.V. INTERIOR PERMIT SUBMITTAL 08.30.12 1 / 4 " = 1 ' - 0 " 1 TH I R D F L O O R D E M O P L A N NO T E : O N L Y T H E I N T E R I O R SC O P E O F W O R K ( S H O W N AB O V E D A S H E D L I N E ) I S IN C L U D E D I N T H I S P E R M I T S E T NO T E : T H E E X T E R I O R S C O P E OF W O R K ( S H O W N B E L O W DA S H E D L I N E ) W A S I N C L U D E D IN T H E E X T E R I O R P E R M I T SE T D A T E D 0 5 . 2 4 . 1 2 ( P E R M I T # B 1 2 - 0 2 1 0 ) GE N E R A L N O T E S : 1. GR A Y H A T C H I N D I C A T E S E X I S T I N G W A L L S . 2. DA S H E D L I N E S I N D I C A T E D E M O L I S H E D / R E M O V E D . NO.DESCRIPTION DATE DE M O W A L L S , D O O R S , ST A I R S , H A N D R A I L S , CA B I N E T S , F I X T U R E S & AP P L I A N C E S S H O W N DA S H E D ST A I R DE C K 2 OP E N T O B E L O W OF F I C E NE W C U S T O M B U I L T - I N WA R D R O B E P E R O W N E R TV BE N C H CA S E D O P E N I N G TO A L I G N W / SK Y L I G H T A B O V E . OP T I O N : I N S T A L L OP E R A B L E O R FI X E D W I N D O W MA S T E R B A T H MA S T E R B E D R O O M EX T E N D E X I S T I N G RA I L I N G T O F U L L HT . W A L L S I N TH E S E L O C A T I O N S 1 4 3 A B C D E 2 6' - 0" 0' - 3 1 / 2 " 6' - 2 " 0' - 3 1 / 2 " 6' - 0 " NE W V A N I T Y , T O I L E T & SH O W E R P E R O W N E R . CO M P L Y W / I R C R 3 0 6 & R 3 0 7 6' + / - NE W I N T E R I O R D O O R S P E R OW N E R ( T Y P . ) LI N E O F D R O P P E D CE I L I N G A B O V E 32 " 30 " 30 " 30 " NE W H A N D R A I L . C O M P L Y W / IR C R 3 1 1 . 7 . 7 CRP TILETILE CRP SCALE PROJECT NUMBER DRAWN BY CHECKED BY COPYRIGHT 2012 As indicated 1476 WESTHAVEN DR. UNIT #3(COLDSTREAM) VAIL, CO 81657PARCEL #210312108003ACCOUNT #R013068 A2.03 THIRD FLOOR PLAN 0611 ML ML KOELBEL RESIDENCE INTERIOR ALTERATION T.O.V. INTERIOR PERMIT SUBMITTAL 08.30.12 1 / 4 " = 1 ' - 0 " 1 TH I R D F L O O R P L A N NO T E : O N L Y T H E I N T E R I O R SC O P E O F W O R K ( S H O W N AB O V E D A S H E D L I N E ) I S IN C L U D E D I N T H I S P E R M I T S E T NO T E : T H E E X T E R I O R S C O P E OF W O R K ( S H O W N B E L O W DA S H E D L I N E ) W A S I N C L U D E D IN T H E E X T E R I O R P E R M I T SE T D A T E D 0 5 . 2 4 . 1 2 ( P E R M I T # B 1 2 - 0 2 1 0 ) GE N E R A L N O T E S : 1. GR A Y H A T C H I N D I C A T E S N E W W A L L S . NO.DESCRIPTION DATE GF I 3 T TV TV 3 3 TT GFI TT 3 4 4 1 4 3 A B C D E 2 DE C K 1 KI T C H E N ST A I R EN T R Y BA T H 1 BE D R O O M 1 CL 3 BUILT-IN STORAGE TV PA N T R Y D/ W W/ D EL E C . P DI N I N G R O O M LI V I N G R O O M RE F . RE L O C A T E RE L O C A T E RE L O C A T E RE L O C A T E RE L O C A T E RE L O C A T E RE L O C A T E RE L O C A T E RE L O C A T E C C D S NE W E L E C T R I C RA D I E N T F L O O R HE A T I N G M A T UN D E R T I L E C FL RE L O C A T E RE L O C A T E FA N O N L Y RE L O C A T E C CC RE L O C A T E RE L O C A T E C C RE L O C A T E UN D E R C A B . L I G H T S 22 0 RE L O C A T E RE L O C A T E TO J - B O X A B O V E SCALE PROJECT NUMBER DRAWN BY CHECKED BY COPYRIGHT 2012 1 DRC PRELIM. REVIEW 05.12.11 2 BID SET 06.15.11 3 T.O.V. PERMIT SET 05.24.12 4 T.O.V. INT. PERMIT SET 08.30.12 As indicated 1476 WESTHAVEN DR. UNIT #3(COLDSTREAM) VAIL, CO 81657PARCEL #210312108003ACCOUNT #R013068 A2.04 SECOND FLOOR LIGHTING & ELECTRICAL PLAN 0611 KOELBEL RESIDENCE INTERIOR ALTERATION Author Checker T.O.V. INTERIOR PERMIT SUBMITTAL 08.30.12 1 / 4 " = 1 ' - 0 " 1 SE C O N D F L O O R L I G H T I N G & EL E C T R I C A L P L A N GE N E R A L N O T E S : 1. ON L Y N E W & R E L O C A T E D E L E C T R I C A L FI X T U R E S ( L I G H T I N G , S W I T C H I N G , O U T L E T S , CA B L E , C A T 5 , T E L E P H O N E , T H E R M O S T A T & H E A T RE G I S T E R S ) A R E S H O W N . 2. RE L O C A T E D E X I S T I N G E L E C T R I C A L F I X T U R E S AR E N O T E D . 3. EX I S T I N G E L E C T R I C A L F I X T U R E S O N D E M O WA L L S T H A T A R E N O T R E L O C A T E D A R E T O B E AB A N D O N E D . 4. RE M O V E A L L H U M I D I F I C A T I O N U N I T S & T H E I R CO N T R O L S . 5. AL L E X I S T I N G H E A T R E G I S T E R S A R E T O B E RE P L A C E D W / N E W H E A T R E G I S T E R S O F T H E SA M E H E A T I N G C A P A C I T Y . NO.DESCRIPTION DATE Receptalce To be installed per 2011 NEC Provide load calculations T 3 TV 3 GF I 3 GF I TV T T T 44 4 J 1 4 3 A B C D E 2 ST A I R DE C K 2 OP E N T O B E L O W OF F I C E BE N C H MA S T E R B A T H MA S T E R B E D R O O M S RE L O C A T E RE L O C A T E RE L O C A T E RE L O C A T E RE L O C A T E RE L O C A T E C RE L O C A T E C NE W E L E C T R I C RA D I E N T F L O O R HE A T I N G M A T UN D E R T I L E RE L O C A T E RE L O C A T E FA N O N L Y C FL TO S W I T C H B E L O W SCALE PROJECT NUMBER DRAWN BY CHECKED BY COPYRIGHT 2012 1 DRC PRELIM. REVIEW 05.12.11 2 BID SET 06.15.11 3 T.O.V. PERMIT SET 05.24.12 4 T.O.V. INT. PERMIT SET 08.30.12 As indicated 1476 WESTHAVEN DR. UNIT #3(COLDSTREAM) VAIL, CO 81657PARCEL #210312108003ACCOUNT #R013068 A2.05 THIRD FLOOR LIGHTING & ELECTRICAL PLAN 0611 KOELBEL RESIDENCE INTERIOR ALTERATION Author Checker T.O.V. INTERIOR PERMIT SUBMITTAL 08.30.12 1 / 4 " = 1 ' - 0 " 1 TH I R D F L O O R L I G H T I N G & E L E C T R I C A L PL A N NO.DESCRIPTION DATE GE N E R A L N O T E S : 1. ON L Y N E W & R E L O C A T E D E L E C T R I C A L FI X T U R E S ( L I G H T I N G , S W I T C H I N G , O U T L E T S , CA B L E , C A T 5 , T E L E P H O N E , T H E R M O S T A T & H E A T RE G I S T E R S ) A R E S H O W N . 2. RE L O C A T E D E X I S T I N G E L E C T R I C A L F I X T U R E S AR E N O T E D . 3. EX I S T I N G E L E C T R I C A L F I X T U R E S O N D E M O WA L L S T H A T A R E N O T R E L O C A T E D A R E T O B E AB A N D O N E D . 4. RE M O V E A L L H U M I D I F I C A T I O N U N I T S & T H E I R CO N T R O L S . 5. AL L E X I S T I N G H E A T R E G I S T E R S A R E T O B E RE P L A C E D W / N E W H E A T R E G I S T E R S O F T H E SA M E H E A T I N G C A P A C I T Y . receptacle