HomeMy WebLinkAboutB12-0210 - REV1 - 090412 corrections requiredSCALE
PROJECT NUMBER
DRAWN BY
CHECKED BY
COPYRIGHT 2012
1DRC PRELIM. REVIEW05.12.11
2BID SET06.15.11
3T.O.V. PERMIT SET05.24.12
4T.O.V. INT. PERMIT SET08.30.12
12" = 1'-0"
1476 WESTHAVEN DR. UNIT #3(COLDSTREAM) VAIL, CO 81657PARCEL #210312108003ACCOUNT #R013068
A1.00
COVER SHEET
0611
KOELBEL
RESIDENCE
INTERIOR
ALTERATION
ML
ML
T.O.V. INTERIOR
PERMIT SUBMITTAL
08.30.12
DRAWING INDEX
GENERAL
A1.00 COVER SHEET
A1.01 GENERAL NOTES
ARCHITECTURAL
A2.00 SECOND FLOOR DEMO PLAN
A2.01 SECOND FLOOR PLAN
A2.02 THIRD FLOOR DEMO PLAN
A2.03 THIRD FLOOR PLAN
A2.04 SECOND FLOOR LIGHTING & ELECTRICAL PLAN
A2.05 THIRD FLOOR LIGHTING & ELECTRICAL PLAN
VICINITY MAP GRAPHIC SCALE = 150'
PROJECT NARRATIVE
THE PROPOSED INTERIOR RENOVATION INCLUDES THE FOLLOWING:
1.RECONFIGURED INTERIOR WALLS.
2.NEW FINISHED FLOORINGS.
3.NEW FIXED FINISHES.
4.NEW BATHROOM FIXTURES.
5.NEW KITCHEN FIXTURES & APPLIANCES.
6.NEW CABINETRY & COUNTERTOPS.
7.NEW LIGHTING.
8.NEW BUILT-IN CABINETRY
PROJECT DIRECTORY
OWNER
ELDORADO REALTY CO
5291 E. YALE AVE
DENVER, CO 80222
303.662.0657 P
ROBERT KOELBEL
BOB@KOELBELHOMES.COM
GENERAL CONTRACTOR
MINICK CONSTRUCTION
PO BOX 4018
VAIL, CO 81658
T.O.V. CONSTRUCTION
LICENSE #24B
970.904.5066 P
DAVE MINICK
DKMINICK@YAHOO.COM
ARCHITECT
8150 ARCHITECTS LLC
PO BOX 3604
VAIL, CO 81658
970.376.3326 P
888.879.2105 F
MATT LEE AIA, LEED AP
MATT@8150ARCHITECTS.COM
UNIT #3
WE
S
T
H
A
V
E
N
D
R
GORE CREEK
COLDSTREAM
NO.DESCRIPTIONDATE
RECEIV
VED
09/04/12
A101
1 SIM
101
Room name
101
1
A101
SIM
1i
1t
1
1A101
SIM
SECTION
ELEVATION
DETAIL/ENLARGED PLAN
GRID
REVISION
0
NORTH ARROW
ELEVATION
WALL TAG
WINDOW TAG
DOOR TAG
ROOM TAG
NameElevation
ROOM NAME
SCALE
PROJECT NUMBER
DRAWN BY
CHECKED BY
COPYRIGHT 2012
1DRC PRELIM. REVIEW05.12.11
2BID SET06.15.11
3T.O.V. PERMIT SET05.24.12
4T.O.V. INT. PERMIT SET08.30.12
As indicated
1476 WESTHAVEN DR. UNIT #3(COLDSTREAM) VAIL, CO 81657PARCEL #210312108003ACCOUNT #R013068
A1.01
GENERAL NOTES
0611
KOELBEL
RESIDENCE
INTERIOR
ALTERATION
ML
ML
T.O.V. INTERIOR
PERMIT SUBMITTAL
08.30.12
GENERAL NOTES
1. THE AIA DOCUMENT A105, STANDARD FORM OF AGREEMENT BETWEEN OWNER AND CONTRACTOR FOR A RESIDENTIAL OR SMALL COMMERCIAL PROJECT, 2007 EDITION, IS HEREBY MADE A PART OF THESE CONTRACT
DOCUMENTS. COPIES ARE INCLUDED IN THE PROJECT MANUAL AND ARE AVAILABLE FOR INSPECTION AT THE OFFICES OF THE ARCHITECT.
2. THE CONTRACT DOCUMENTS CONSIST OF THE GENERAL CONDITIONS OF THE CONTRACT FOR CONSTRUCTION, THE GENERAL NOTES, THE SPECIFICATIONS, AND THE DRAWINGS, WHICH ARE COOPERATIVE AND CONTINUOUS.
WORK INDICATED OR REASONABLY IMPLIED IN ANY ONE OF THE DOCUMENTS SHALL BE SUPPLIED AS THOUGH FULLY COVERED IN ALL. ANY DISCREPANCY BETWEEN THE DIFFERENT PARTS SHOULD BE REPORTED TO THE
ARCHITECT IMMEDIATELY.3. ALL WORK SHALL COMPLY WITH ALL STATE AND LOCAL CODES AND ORDINANCES, THE CONTRACTOR SHALL BE RESPONSIBLE FOR SATISFYING ALL APPLICABLE CODES AND OBTAINING ALL PERMITS AND REQUIREDAPPROVALS.4. IT IS THE INTENT AND MEANING OF THESE DOCUMENTS THAT THE CONTRACTOR AND EACH SUBCONTRACTOR PROVIDE ALL LABOR, MATERIALS, TRANSPORTATION, SUPPLIES, EQUIPMENT, ETC. TO OBTAIN A COMPLETE JOBWITHIN THE RECOGNIZED STANDARDS OF THE INDUSTRY. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO BRING TO THE ATTENTION OF THE ARCHITECT ANY CONDITIONS WHICH WILL NOT PERMIT CONSTRUCTIONACCORDING TO THE INTENTIONS OF THESE DOCUMENTS. IT IS THE RESPONSIBILITY OF THE ARCHITECT TO PROVIDE DETAILS AND/OR DIRECTIONS REGARDING DESIGN INTENT WHERE IT IS ALTERED BY EXISTING CONDITIONSOR WHERE NEGLECTED IN THE DOCUMENTS. IN THE EVENT THAT ADDITIONAL DETAILS OR GUIDANCE IS NEEDED BY THE CONTRACTOR FOR CONSTRUCTION OF ANY ASPECTS OF THIS PROJECT, THE CONTRACTOR SHALLIMMEDIATELY NOTIFY THE ARCHITECT.5. VERIFY ALL DIMENSIONS, EXISTING CONDITIONS AND UTILITY LOCATIONS ON THE JOB SITE PRIOR TO BEGINNING ANY WORK OR ORDERING ANY MATERIALS.6. NOTIFY ARCHITECT OF ANY CONFLICTS OR DISCREPANCIES IN THE DOCUMENTS IMMEDIATELY. AREAS OF CONFLICTS OR DISCREPANCIES MUST BE FULLY RESOLVED WITH WRITTEN APPROVAL FROM THE ARCHITECTBEFORE CONSTRUCTION CONTINUES IN THOSE AREAS.
7. CONTRACTOR TO SUMBIT CUT SHEETS/SPECIFICATIONS AND SAMPLES* OF ALL PRODUCTS & MATERIALS FOR ARCHITECT'S APPROVAL PRIOR TO ORDERING PRODUCTS & MATERIALS. *SOME PRODUCTS MAY NOT REQUIRE A
SAMPLE TO BE SUBMITTED (COORDINATE W/ ARCHITECT).
8. ANY MATERIALS PROPOSED FOR SUBSTITUTION OF THOSE SPECIFIED OR CALLED OUT BY TRADE NAME IN THESE DOCUMENTS SHALL BE PRESENTED TO THE ARCHITECT FOR REVIEW. THE CONTRACTOR SHALL SUBMIT
SAMPLES WHEN REQUIRED BY THE ARCHITECT AND ALL SUCH SAMPLES SHALL BE REVIEWED BY THE ARCHITECT BEFORE THE WORK IS PERFORMED. WORK MUST CONFORM TO THE REVIEWED SAMPLES. ANY WORK WHICH
DOES NOT CONFORM SHALL BE REMOVED AND REPLACED WITH WORK WHICH CONFORMS AT THE CONTRACTOR'S EXPENSE. SUBCONTRACTORS SHALL SUBMIT REQUESTS AND SAMPLES FOR REVIEW THROUGH THE GENERAL
CONTRACTOR WHEN WORK IS LET THROUGH HIM OR HER. REQUIRED VERIFICATIONS AND SUBMITTALS TO BE MADE IN ADEQUATE TIME AS NOT TO DELAY WORK IN PROGRESS.9. SHOP DRAWINGS SHALL BE SUBMITTED TO THE ARCHITECT FOR HIS OR HER REVIEW WHERE CALLED FOR ANYWHERE IN THESE DOCUMENTS. REVIEW SHALL BE MADE BY THE ARCHITECT BEFORE WORK IS BEGUN, ANDWORK SHALL CONFORM TO THE REVIEWED SHOP DRAWINGS, SUBJECT TO REPLACEMENT AS REQUIRED IN PARAGRAPH 8, ABOVE.10. THE BUILDING INSPECTOR SHALL BE NOTIFIED BY THE CONTRACTOR WHEN THERE IS NEED OF INSPECTION AS REQUIRED BY THE INTERNATIONAL RESIDENTIAL CODE, THE INTERNATIONAL BUILDING CODE OR ANY LOCALCODE OR ORDINANCE.11. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE SAFETY AND CARE OF ADJACENT PROPERTIES DURING CONSTRUCTION, FOR COMPLIANCE WITH FEDERAL AND STATE O.S.H.A. REGULATIONS, AND FOR THEPROTECTION OF ALL WORK UNTIL IT IS DELIVERED COMPLETED TO THE OWNER.12. DO NOT SCALE DRAWINGS. ALL DIMENSIONS NOTED TAKE PRECEDENCE OVER SCALED DIMENSIONS. DIMENSIONS NOTED WITH "N.T.S." DENOTES NOT TO SCALE.13. PLAN DIMENSIONS ARE TO FACE OF STUD/STRUCTURE, FACE OF COLUMN OR FACE OF CONCRETE UNLESS OTHERWISE NOTED. SECTION AND ELEVATION DIMENSIONS ARE TO FACE OF STUD/STRUCTUR, FACE OF COLUMN,FACE OF CONCRETE, TOP OF CONCRETE, TOP OF PLYWOOD, TOP OF WALL PLATES OR TOP OF BEAMS UNLESS OTHERWISE NOTED.14. THE CONTRACTOR SHALL VERIFY ALL EXISTING GRADES AND STAKE OUT PROPOSED WORK FOR OWNER AND ARCHITECT APPROVAL PRIOR TO BEGINNING ANY SITE WORK.
15. CONTRACTOR SHALL VERIFY AND COORDINATE ALL OPENINGS THROUGH FLOORS, CEILINGS, AND WALLS WITH ALL ARCHITECTURAL, STRUCTURAL, MECHANICAL, PLUMBING, AND ELECTRICAL DRAWINGS. THE CONTRACTOR
SHALL FIELD COORDINATE AND OBTAIN APPROVAL FROM THE ARCHITECT & ENGINEER BEFORE ANY CUTTING, NOTCHING OR DRILLING OF ANY CAST-IN-PLACE CONCRETE, STEEL FRAMING, OR ANY OTHER STRUCTURAL
ELEMENTS WHICH MAY AFFECT THE STRUCTURAL INTEGRITY OF THE BUILDING.
16. COORDINATE ALL ELECTRICAL AND MECHANICAL FIXTURES TO FIT WITHIN CEILING, FLOOR AND WALLS SPACES. VERIFY LOCATIONS WITH ARCHITECT.17. PROVIDE ALL NECESSARY BLOCKING IN STUD WALLS AND CEILINGS. LOCATIONS INCLUDE BUT ARE NOT LIMITED TO CEILING AND WALL MOUNTED FIXTURES, TOILETS, TOILET ACCESSORIES, GRAB BARS, CABINETRY,COUNTERTOPS, SHELVES AND CLOSET RODS.18. CONTRACTOR WILL ASSUME RESPONSIBILITY OF ITEMS REQUIRING COORDINATION AND RESOLUTION DURING THE BIDDING PROCESS.
BIDDING NOTES
1. DRAWINGS OF EXISTING CONDITIONS ARE BASED OFF OF ROUGH FIELD SURVEYS. ALL LOCATIONS, DIMENSIONS, AREAS, SCHEDULES, QUANTITIES & MATERIAL TAKEOFFS OF EXISTING CONDITIONS GIVEN ARE FORREPRESENTING THE SCOPE OF THE WORK & GENERAL ORDER OF MAGNITUDE ESTIMATING. THEY ARE NOT TO BE RELIED UPON FOR ACCURATE BID ESTIMATING. IT IS THE RESPONSIBLITY OF THE CONTRACTOR TO FIELDVERIFY ALL LOCATIONS, DIMENSIONS, AREAS, SCHEDULES, QUANTITIES & MATERIAL TAKEOFFS PRIOR TO SUBMITTING HIS/HER BID.2. CONTRACTOR TO INCLUDE ALL ASSOCIATED COSTS (EXCEPT FOR BUILDING PERMITS & SIMILAR FEES) TO PERFORM THE WORK INCLUDING BUT NOT LIMITED TO: DEMOLITION, HAUL & DUMP FEES, SITE FENCING, BUILDING
PROTECTION, OFF & ON-SITE MATERIAL STORAGE.
3. CONTRACTOR TO PROVIDE EVIDENCE OF INSURANCE. CONTRACTOR & SUBCONTRACTORS TO NAME OWNER AS "ADDITIONALLY INSURED" FOR THE DURATION OF THE WORK.
ABBREVIATIONS
ABV ABOVEAFFABOVE FINISHED FLOORAPACCESS PANELACACOUSTICALADAAGADA ACCESSIBILITY GUIDELINESADDADDENDUM
ADJ ADJACENT
ALT ALTERNATE
ALUM ALUMINUM
AIA AMERICAN INSTITUTE OF ARCHITECTSANSIAMERICAN NATIONAL STANDARDS INSTITUTEASTMAMERICAN SOCIETY FOR TESTING & MATERIALSADAAMERICANS WITH DISABILITIESARCHARCHITECT(URAL)ASI ARCHITECT’S SUPPLEMENTAL INSTRUCTIONSABAARCHITECTURAL BARRIERS ACTAHJAUTHORITY HAVING JURISDICTIONBASMTBASEMENTBRGBEARINGBVLBEVELEDBITBITUMINUOUS
BLK BLOCK
BLKG BLOCKING
BOT BOTTOM
BLDG BUILDINGCPTCARPET(ED)CSMT CASEMENTCCAULK(ING)CLG CEILINGCENTERLINECTCERAMIC TILECLRCLEARCLCLOSETCOLCOLUMNCONCCONCRETE
CMU CONCRETE MASONRY UNIT
CONST CONSTRUCTION
CSI CONSTRUCTION SPECIFICATIONS INSTITUTE
CONT CONTINUOUS
CJT CONTROL JOINT
CPR COPPERCUSTCUSTOMDDEPTH, DEEP
DTL DETAILDIMDIMENSIONDRDOORDSDOWNSPOUTDTDRAPERY TROUGH
DWG DRAWING(S)
DF DRINKING FOUNTAIN
ELEC ELECTRIC(AL)
ELEV ELEVATION(S)EL ELEVATORERVENERGY RECOVERY VENTILATOREQEQUALETCET CETERAEPDMETHYLENE PROPYLENE DIENE MONOMEREXHEXHAUSTEXISTEXISTINGEXTEXTERIORFOCFACE OF CONCRETE (COLUMN)FOF FACE OF FINISHFOMFACE OF MASONRY
FOS FACE OF STRUCTURE (STUD(S))
FIN FINISH(ED)
FFE FINISHED FLOOR ELEVATION
FE FIRE EXTINGUISHER
FDC FIRE DEPARTMENT CONNECTIONFHCFIRE HOSE CONNECTIONFECFIRE EXTINGUISHER CABINETFPLFIREPLACEFPFIREPROOFINGFLGFLASHINGFLRFLOOR(ING)FD FLOOR DRAINFTGFOOTINGFNDFOUNDATIONFBOFURNISHED BY OTHERS (OWNER)
FPHB FREEZE PROOF HOSE BIB
FURR FURRED, FURRING
GA GAGE, GAUGE
GV GALVANIZED
GC GENERAL CONTRACT(OR)GL GLAZING, GLASSGSFGROSS SQUARE FOOTAGEGYPGYPSUM
GWB GYPSUM WALL BOARDHBHOSE BIBHDWHARDWAREHDRHEADERHTGHEATING
HVAC HEATING VENTILATING & AIR CONDITIONING
HT HEAVY TIMBER, HEIGHT
HC HOLLOW CORE
HM HOLLOW METALHORHORIZONTALHWHHOT WATER HEATERINCLINCLUDE(D), INCULDINGIDINSIDE DIAMETERIBOINSTALLED BY OTHERS/OWNERINSINSULATE(D), INSULATIONINTINTERIORIBCINTERNATIONAL BUILDING CODE,INSTALLED BY CONTRACTORICCINTERNATIONAL CODE COUNCILIRCINTERNATIONAL RESIDENTIAL CODE
JC JANITOR’S CLOSET
KIT KITCHEN
LAM LAMINATE(D)
LAV LAVATORY
LH LEFT HANDLLENGTHLDTLIGHT & DRAPERY TROUGHLTLIGHT, LIGHT TROUGHLTLLINTELLVRLOUVERMHMANHOLEMFRMANUFACTURE(D), MANUFACTURERMOMASONRY OPENINGMTLMATERIALMAXMAXIMUM
MECH MECHANIC(AL)
MEP MECHANICAL/ELECTRICAL/PLUMBING (ENG.)
MC MEDICINE CABINET
MB MEMBRANE
MET METALMMETER(S)MM MILLIMETER(S)MIN MINIMUM
MIR MIRRORMISCMISCELLANEOUSMULLMULLIONNFPANATIONAL FIRE PROTECTION ASSOCIATIONNATNATURAL
NSF NET SQUARE FOOTAGE
NLSF NET LEASABLE SQUARE FOOTAGE
NOM NOMINAL
N/A NOT APPLICABLENICNOT IN CONTRACTNRNOT-RATED, NOISE REDUCTIONNTSNOT TO SCALEOCON CENTEROPGOPENINGOPPOPPOSITEOPHOPPOSITE HANDOHOVERHEADPRPAIRPKPARKINGPVMTPAVEMENT
PL PLASTIC LAMINATE, PLATE, PROPERTY LINE
PT POINT, PRESSURE TREATED
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
QT QUARRY TILERECRECOMMENDATION(S)RE REFER(ENCE)REFR REFRIGERATORREINFREINFORCE(D), REINFORCINGRFIREQUEST FOR INFORMATION/CLARIFICATIONREQ’D REQUIREDRESRESILIENTREVREVISION(S)REVS REVERSERHRIGHT HAND
R RISER
R&S ROD & SHELF
RD ROOF DRAIN
RDT RECESSED DRAPERY TRACK
RFG ROOFINGRMROOMROROUGH OPENINGR/S ROUGH SAWN
S SEALANTSHTGSHEATHINGSMSHEET METALSIMSIMILARSCSOLID CORE
SPEC SPECIFICATION(S)
SQ SQUARE
SQ FT SQUARE FOOT(AGE)
STD STANDARDSTSTAINSSSTAINLESS STEELSTLSTEELSDSTORM DRAINSTRUCT STRUCTURE, STRUCTURALTELTELEPHONETVTELEVISIONTHRTHRESHOLDT&M TIME & MATERIALST&G TONGUE & GROOVETOBTOP OF BEAM
TOS TOP OF SLAB/STEEL/STRUCTURE
TOW TOP OF WALL
TB TOWEL BAR
TR TRANSOM
T TREADTSTUBE STEELTYPTYPICALULUNDERWRITERS LABORATORIESUFASUNIFORM FEDERAL ACCESSIBLITY STANDARDSUNOUNLESS NOTED OTHERWISEVBVAPOR BARRIERVIFVERIFY IN FIELDVERTVERTICALVCTVINYL COMPOSITION TILEWBWALL BOARD
WC WATER CLOSET
WP WATERPROOF(ING)
WWF WELDED WIRE FABRIC
W WIDTH, WIDE
WDW WINDOWW/WITHW/O WITHOUTWDWOOD
NO.DESCRIPTIONDATE
RE
L
O
C
A
T
E
D
O
O
R
T
O
NE
W
W
A
L
L
DE
M
O
H
E
A
R
T
H
DE
M
O
W
A
L
L
S
DE
M
O
G
U
A
R
D
R
A
I
L
DE
M
O
F
I
R
E
P
L
A
C
E
&
F
L
U
E
DI
N
I
N
G
R
O
O
M
RE
L
O
C
A
T
E
LI
G
H
T
FI
X
T
U
R
E
DE
C
K
1
LI
V
I
N
G
R
O
O
M
ST
A
I
R
EN
T
R
Y
BA
T
H
1
BE
D
R
O
O
M
1
CL
3
EL
E
C
.
P
KI
T
C
H
E
N
CL
2
CL
1
1
4
3
A
B
C D E
2
SCALE
PROJECT NUMBER
DRAWN BY
CHECKED BY
COPYRIGHT 2012
1DRC PRELIM. REVIEW05.12.11
2BID SET06.15.11
3T.O.V. PERMIT SET05.24.12
4T.O.V. INT. PERMIT SET08.30.12
As indicated
1476 WESTHAVEN DR. UNIT #3(COLDSTREAM) VAIL, CO 81657PARCEL #210312108003ACCOUNT #R013068
A2.00
SECOND FLOOR DEMO
PLAN
0611
KOELBEL
RESIDENCE
INTERIOR
ALTERATION
ML
ML
T.O.V. INTERIOR
PERMIT SUBMITTAL
08.30.12
1
/
4
"
=
1
'
-
0
"
1
SE
C
O
N
D
F
L
O
O
R
D
E
M
O
P
L
A
N
NO
T
E
:
O
N
L
Y
T
H
E
I
N
T
E
R
I
O
R
SC
O
P
E
O
F
W
O
R
K
(
S
H
O
W
N
AB
O
V
E
D
A
S
H
E
D
L
I
N
E
)
I
S
IN
C
L
U
D
E
D
I
N
T
H
I
S
P
E
R
M
I
T
S
E
T
NO
T
E
:
T
H
E
E
X
T
E
R
I
O
R
S
C
O
P
E
OF
W
O
R
K
(
S
H
O
W
N
B
E
L
O
W
DA
S
H
E
D
L
I
N
E
)
W
A
S
I
N
C
L
U
D
E
D
IN
T
H
E
E
X
T
E
R
I
O
R
P
E
R
M
I
T
SE
T
D
A
T
E
D
0
5
.
2
4
.
1
2
(
P
E
R
M
I
T
#
B
1
2
-
0
2
1
0
)
GE
N
E
R
A
L
N
O
T
E
S
:
1.
GR
A
Y
H
A
T
C
H
I
N
D
I
C
A
T
E
S
E
X
I
S
T
I
N
G
W
A
L
L
S
.
2.
DA
S
H
E
D
L
I
N
E
S
I
N
D
I
C
A
T
E
D
E
M
O
L
I
S
H
E
D
/
R
E
M
O
V
E
D
.
NO.DESCRIPTIONDATE
DE
M
O
W
A
L
L
S
,
D
O
O
R
S
,
ST
A
I
R
S
,
H
A
N
D
R
A
I
L
S
,
CA
B
I
N
E
T
S
,
F
I
X
T
U
R
E
S
&
AP
P
L
I
A
N
C
E
S
S
H
O
W
N
DA
S
H
E
D
NE
W
E
X
T
E
R
I
O
R
W
A
L
L
S
RE
L
O
C
A
T
E
D
DO
O
R
NE
W
I
N
T
E
R
I
O
R
WA
L
L
.
M
A
I
N
T
A
I
N
CH
A
S
E
F
I
R
E
R
A
T
I
N
G
NE
W
G
U
A
R
D
R
A
I
L
DE
C
K
1
RE
L
O
C
A
T
E
D
LI
G
H
T
F
I
X
T
U
R
E
KI
T
C
H
E
N
ST
A
I
R
EN
T
R
Y
BA
T
H
1
BE
D
R
O
O
M
1
CL
3
NE
W
C
U
S
T
O
M
B
U
I
L
T
-
I
N
WA
R
D
R
O
B
E
P
E
R
O
W
N
E
R
NEW CUSTOM BUILT-IN
STORAGE PER OWNER
NE
W
S
K
I
R
A
C
K
P
E
R
O
W
N
E
R
TV
PA
N
T
R
Y
D/
W
W/
D
RE
C
O
N
S
T
R
U
C
T
W
A
L
L
S
A
S
OP
E
N
G
U
A
R
D
R
A
I
L
S
P
E
R
OW
N
E
R
.
C
O
M
P
L
Y
W
/
I
R
C
R
3
1
2
TV
NE
W
K
I
T
C
H
E
N
CA
B
I
N
E
T
S
,
CO
U
N
T
E
R
T
O
P
S
,
FI
X
T
U
R
E
S
&
AP
P
L
I
A
N
C
E
S
P
E
R
OW
N
E
R
.
C
O
M
P
L
Y
W/
I
R
C
R
3
0
6
EL
E
C
.
P
OP
T
I
O
N
:
D
E
M
O
D
W
H
&
W
A
L
L
S
.
IN
S
T
A
L
L
E
L
E
C
T
.
T
A
N
K
L
E
S
S
DW
H
&
T
W
O
S
I
N
K
V
A
N
I
T
Y
DI
N
I
N
G
R
O
O
M
LI
V
I
N
G
R
O
O
M
1
4
3
A
B
C D E
2
RE
F
.
NE
W
C
U
S
T
O
M
CA
B
I
N
E
T
R
Y
F
O
R
WA
S
H
E
R
/
D
R
Y
E
R
,
PA
N
T
R
Y
&
RE
F
R
I
G
E
R
A
T
O
R
3' - 4"
NE
W
V
A
N
I
T
Y
,
TO
I
L
E
T
&
S
H
O
W
E
R
PE
R
O
W
N
E
R
.
CO
M
P
L
Y
W
/
I
R
C
R3
0
6
&
R
3
0
7
NE
W
I
N
T
E
R
I
O
R
D
O
O
R
S
P
E
R
OW
N
E
R
(
T
Y
P
.
)
TI
L
E
C
R
P
TILE CRP
WOOD TILE CRP WOOD
32
"
30
"
30
"
24
"
NE
W
H
A
N
D
R
A
I
L
.
C
O
M
P
L
Y
W
/
IR
C
R
3
1
1
.
7
.
7
SCALE
PROJECT NUMBER
DRAWN BY
CHECKED BY
COPYRIGHT 2012
1 DRC PRELIM. REVIEW 05.12.11
2 BID SET 06.15.11
3 T.O.V. PERMIT SET 05.24.12
4 T.O.V. INT. PERMIT SET 08.30.12
As indicated
1476 WESTHAVEN DR. UNIT #3(COLDSTREAM) VAIL, CO 81657PARCEL #210312108003ACCOUNT #R013068
A2.01
SECOND FLOOR PLAN
0611
KOELBEL
RESIDENCE
INTERIOR
ALTERATION
ML
ML
T.O.V. INTERIOR
PERMIT SUBMITTAL
08.30.12
1
/
4
"
=
1
'
-
0
"
1
SE
C
O
N
D
F
L
O
O
R
P
L
A
N
GE
N
E
R
A
L
N
O
T
E
S
:
1.
GR
A
Y
H
A
T
C
H
I
N
D
I
C
A
T
E
S
N
E
W
W
A
L
L
S
.
NO
T
E
:
O
N
L
Y
T
H
E
I
N
T
E
R
I
O
R
SC
O
P
E
O
F
W
O
R
K
(
S
H
O
W
N
AB
O
V
E
D
A
S
H
E
D
L
I
N
E
)
I
S
IN
C
L
U
D
E
D
I
N
T
H
I
S
P
E
R
M
I
T
S
E
T
NO
T
E
:
T
H
E
E
X
T
E
R
I
O
R
S
C
O
P
E
OF
W
O
R
K
(
S
H
O
W
N
B
E
L
O
W
DA
S
H
E
D
L
I
N
E
)
W
A
S
I
N
C
L
U
D
E
D
IN
T
H
E
E
X
T
E
R
I
O
R
P
E
R
M
I
T
SE
T
D
A
T
E
D
0
5
.
2
4
.
1
2
(
P
E
R
M
I
T
#
B
1
2
-
0
2
1
0
)
NO.DESCRIPTION DATE
ST
A
I
R
MA
S
T
E
R
B
A
T
H
MA
S
T
E
R
B
E
D
R
O
O
M
DE
C
K
2
OP
E
N
T
O
B
E
L
O
W
OF
F
I
C
E
MA
S
T
E
R
C
L
O
S
E
T
1
4
3
A
B
C D E
2
SCALE
PROJECT NUMBER
DRAWN BY
CHECKED BY
COPYRIGHT 2012
As indicated
1476 WESTHAVEN DR. UNIT #3(COLDSTREAM) VAIL, CO 81657PARCEL #210312108003ACCOUNT #R013068
A2.02
THRID FLOOR DEMO
PLAN
0611
Author
Checker
KOELBEL
RESIDENCE
INTERIOR
ALTERATION
T.O.V. INTERIOR
PERMIT SUBMITTAL
08.30.12
1
/
4
"
=
1
'
-
0
"
1
TH
I
R
D
F
L
O
O
R
D
E
M
O
P
L
A
N
NO
T
E
:
O
N
L
Y
T
H
E
I
N
T
E
R
I
O
R
SC
O
P
E
O
F
W
O
R
K
(
S
H
O
W
N
AB
O
V
E
D
A
S
H
E
D
L
I
N
E
)
I
S
IN
C
L
U
D
E
D
I
N
T
H
I
S
P
E
R
M
I
T
S
E
T
NO
T
E
:
T
H
E
E
X
T
E
R
I
O
R
S
C
O
P
E
OF
W
O
R
K
(
S
H
O
W
N
B
E
L
O
W
DA
S
H
E
D
L
I
N
E
)
W
A
S
I
N
C
L
U
D
E
D
IN
T
H
E
E
X
T
E
R
I
O
R
P
E
R
M
I
T
SE
T
D
A
T
E
D
0
5
.
2
4
.
1
2
(
P
E
R
M
I
T
#
B
1
2
-
0
2
1
0
)
GE
N
E
R
A
L
N
O
T
E
S
:
1.
GR
A
Y
H
A
T
C
H
I
N
D
I
C
A
T
E
S
E
X
I
S
T
I
N
G
W
A
L
L
S
.
2.
DA
S
H
E
D
L
I
N
E
S
I
N
D
I
C
A
T
E
D
E
M
O
L
I
S
H
E
D
/
R
E
M
O
V
E
D
.
NO.DESCRIPTION DATE
DE
M
O
W
A
L
L
S
,
D
O
O
R
S
,
ST
A
I
R
S
,
H
A
N
D
R
A
I
L
S
,
CA
B
I
N
E
T
S
,
F
I
X
T
U
R
E
S
&
AP
P
L
I
A
N
C
E
S
S
H
O
W
N
DA
S
H
E
D
ST
A
I
R
DE
C
K
2
OP
E
N
T
O
B
E
L
O
W
OF
F
I
C
E
NE
W
C
U
S
T
O
M
B
U
I
L
T
-
I
N
WA
R
D
R
O
B
E
P
E
R
O
W
N
E
R
TV
BE
N
C
H
CA
S
E
D
O
P
E
N
I
N
G
TO
A
L
I
G
N
W
/
SK
Y
L
I
G
H
T
A
B
O
V
E
.
OP
T
I
O
N
:
I
N
S
T
A
L
L
OP
E
R
A
B
L
E
O
R
FI
X
E
D
W
I
N
D
O
W
MA
S
T
E
R
B
A
T
H
MA
S
T
E
R
B
E
D
R
O
O
M
EX
T
E
N
D
E
X
I
S
T
I
N
G
RA
I
L
I
N
G
T
O
F
U
L
L
HT
.
W
A
L
L
S
I
N
TH
E
S
E
L
O
C
A
T
I
O
N
S
1
4
3
A
B
C D E
2
6' - 0"
0'
-
3
1
/
2
"
6'
-
2
"
0'
-
3
1
/
2
"
6'
-
0
"
NE
W
V
A
N
I
T
Y
,
T
O
I
L
E
T
&
SH
O
W
E
R
P
E
R
O
W
N
E
R
.
CO
M
P
L
Y
W
/
I
R
C
R
3
0
6
&
R
3
0
7
6'
+
/
-
NE
W
I
N
T
E
R
I
O
R
D
O
O
R
S
P
E
R
OW
N
E
R
(
T
Y
P
.
)
LI
N
E
O
F
D
R
O
P
P
E
D
CE
I
L
I
N
G
A
B
O
V
E
32
"
30
"
30
"
30
"
NE
W
H
A
N
D
R
A
I
L
.
C
O
M
P
L
Y
W
/
IR
C
R
3
1
1
.
7
.
7
CRP TILETILE CRP
SCALE
PROJECT NUMBER
DRAWN BY
CHECKED BY
COPYRIGHT 2012
As indicated
1476 WESTHAVEN DR. UNIT #3(COLDSTREAM) VAIL, CO 81657PARCEL #210312108003ACCOUNT #R013068
A2.03
THIRD FLOOR PLAN
0611
ML
ML
KOELBEL
RESIDENCE
INTERIOR
ALTERATION
T.O.V. INTERIOR
PERMIT SUBMITTAL
08.30.12
1
/
4
"
=
1
'
-
0
"
1
TH
I
R
D
F
L
O
O
R
P
L
A
N
NO
T
E
:
O
N
L
Y
T
H
E
I
N
T
E
R
I
O
R
SC
O
P
E
O
F
W
O
R
K
(
S
H
O
W
N
AB
O
V
E
D
A
S
H
E
D
L
I
N
E
)
I
S
IN
C
L
U
D
E
D
I
N
T
H
I
S
P
E
R
M
I
T
S
E
T
NO
T
E
:
T
H
E
E
X
T
E
R
I
O
R
S
C
O
P
E
OF
W
O
R
K
(
S
H
O
W
N
B
E
L
O
W
DA
S
H
E
D
L
I
N
E
)
W
A
S
I
N
C
L
U
D
E
D
IN
T
H
E
E
X
T
E
R
I
O
R
P
E
R
M
I
T
SE
T
D
A
T
E
D
0
5
.
2
4
.
1
2
(
P
E
R
M
I
T
#
B
1
2
-
0
2
1
0
)
GE
N
E
R
A
L
N
O
T
E
S
:
1.
GR
A
Y
H
A
T
C
H
I
N
D
I
C
A
T
E
S
N
E
W
W
A
L
L
S
.
NO.DESCRIPTION DATE
GF
I
3
T
TV
TV
3
3
TT
GFI
TT
3 4
4
1
4
3
A
B
C D E
2
DE
C
K
1
KI
T
C
H
E
N
ST
A
I
R
EN
T
R
Y
BA
T
H
1
BE
D
R
O
O
M
1
CL
3
BUILT-IN STORAGE
TV
PA
N
T
R
Y
D/
W
W/
D
EL
E
C
.
P
DI
N
I
N
G
R
O
O
M
LI
V
I
N
G
R
O
O
M
RE
F
.
RE
L
O
C
A
T
E
RE
L
O
C
A
T
E
RE
L
O
C
A
T
E
RE
L
O
C
A
T
E
RE
L
O
C
A
T
E
RE
L
O
C
A
T
E
RE
L
O
C
A
T
E
RE
L
O
C
A
T
E
RE
L
O
C
A
T
E
C
C
D
S
NE
W
E
L
E
C
T
R
I
C
RA
D
I
E
N
T
F
L
O
O
R
HE
A
T
I
N
G
M
A
T
UN
D
E
R
T
I
L
E
C
FL
RE
L
O
C
A
T
E
RE
L
O
C
A
T
E
FA
N
O
N
L
Y
RE
L
O
C
A
T
E
C
CC
RE
L
O
C
A
T
E
RE
L
O
C
A
T
E
C
C
RE
L
O
C
A
T
E
UN
D
E
R
C
A
B
.
L
I
G
H
T
S
22
0
RE
L
O
C
A
T
E
RE
L
O
C
A
T
E
TO
J
-
B
O
X
A
B
O
V
E
SCALE
PROJECT NUMBER
DRAWN BY
CHECKED BY
COPYRIGHT 2012
1 DRC PRELIM. REVIEW 05.12.11
2 BID SET 06.15.11
3 T.O.V. PERMIT SET 05.24.12
4 T.O.V. INT. PERMIT SET 08.30.12
As indicated
1476 WESTHAVEN DR. UNIT #3(COLDSTREAM) VAIL, CO 81657PARCEL #210312108003ACCOUNT #R013068
A2.04
SECOND FLOOR
LIGHTING & ELECTRICAL
PLAN
0611
KOELBEL
RESIDENCE
INTERIOR
ALTERATION
Author
Checker
T.O.V. INTERIOR
PERMIT SUBMITTAL
08.30.12
1
/
4
"
=
1
'
-
0
"
1
SE
C
O
N
D
F
L
O
O
R
L
I
G
H
T
I
N
G
&
EL
E
C
T
R
I
C
A
L
P
L
A
N
GE
N
E
R
A
L
N
O
T
E
S
:
1.
ON
L
Y
N
E
W
&
R
E
L
O
C
A
T
E
D
E
L
E
C
T
R
I
C
A
L
FI
X
T
U
R
E
S
(
L
I
G
H
T
I
N
G
,
S
W
I
T
C
H
I
N
G
,
O
U
T
L
E
T
S
,
CA
B
L
E
,
C
A
T
5
,
T
E
L
E
P
H
O
N
E
,
T
H
E
R
M
O
S
T
A
T
&
H
E
A
T
RE
G
I
S
T
E
R
S
)
A
R
E
S
H
O
W
N
.
2.
RE
L
O
C
A
T
E
D
E
X
I
S
T
I
N
G
E
L
E
C
T
R
I
C
A
L
F
I
X
T
U
R
E
S
AR
E
N
O
T
E
D
.
3.
EX
I
S
T
I
N
G
E
L
E
C
T
R
I
C
A
L
F
I
X
T
U
R
E
S
O
N
D
E
M
O
WA
L
L
S
T
H
A
T
A
R
E
N
O
T
R
E
L
O
C
A
T
E
D
A
R
E
T
O
B
E
AB
A
N
D
O
N
E
D
.
4.
RE
M
O
V
E
A
L
L
H
U
M
I
D
I
F
I
C
A
T
I
O
N
U
N
I
T
S
&
T
H
E
I
R
CO
N
T
R
O
L
S
.
5.
AL
L
E
X
I
S
T
I
N
G
H
E
A
T
R
E
G
I
S
T
E
R
S
A
R
E
T
O
B
E
RE
P
L
A
C
E
D
W
/
N
E
W
H
E
A
T
R
E
G
I
S
T
E
R
S
O
F
T
H
E
SA
M
E
H
E
A
T
I
N
G
C
A
P
A
C
I
T
Y
.
NO.DESCRIPTION DATE
Receptalce
To be installed per
2011 NEC
Provide load
calculations
T
3
TV
3
GF
I
3
GF
I
TV
T T
T
44
4
J
1
4
3
A
B
C D E
2
ST
A
I
R
DE
C
K
2
OP
E
N
T
O
B
E
L
O
W
OF
F
I
C
E
BE
N
C
H
MA
S
T
E
R
B
A
T
H
MA
S
T
E
R
B
E
D
R
O
O
M
S
RE
L
O
C
A
T
E
RE
L
O
C
A
T
E
RE
L
O
C
A
T
E
RE
L
O
C
A
T
E
RE
L
O
C
A
T
E
RE
L
O
C
A
T
E
C
RE
L
O
C
A
T
E
C
NE
W
E
L
E
C
T
R
I
C
RA
D
I
E
N
T
F
L
O
O
R
HE
A
T
I
N
G
M
A
T
UN
D
E
R
T
I
L
E
RE
L
O
C
A
T
E
RE
L
O
C
A
T
E
FA
N
O
N
L
Y
C
FL
TO
S
W
I
T
C
H
B
E
L
O
W
SCALE
PROJECT NUMBER
DRAWN BY
CHECKED BY
COPYRIGHT 2012
1 DRC PRELIM. REVIEW 05.12.11
2 BID SET 06.15.11
3 T.O.V. PERMIT SET 05.24.12
4 T.O.V. INT. PERMIT SET 08.30.12
As indicated
1476 WESTHAVEN DR. UNIT #3(COLDSTREAM) VAIL, CO 81657PARCEL #210312108003ACCOUNT #R013068
A2.05
THIRD FLOOR LIGHTING
& ELECTRICAL PLAN
0611
KOELBEL
RESIDENCE
INTERIOR
ALTERATION
Author
Checker
T.O.V. INTERIOR
PERMIT SUBMITTAL
08.30.12
1
/
4
"
=
1
'
-
0
"
1
TH
I
R
D
F
L
O
O
R
L
I
G
H
T
I
N
G
&
E
L
E
C
T
R
I
C
A
L
PL
A
N
NO.DESCRIPTION DATE
GE
N
E
R
A
L
N
O
T
E
S
:
1.
ON
L
Y
N
E
W
&
R
E
L
O
C
A
T
E
D
E
L
E
C
T
R
I
C
A
L
FI
X
T
U
R
E
S
(
L
I
G
H
T
I
N
G
,
S
W
I
T
C
H
I
N
G
,
O
U
T
L
E
T
S
,
CA
B
L
E
,
C
A
T
5
,
T
E
L
E
P
H
O
N
E
,
T
H
E
R
M
O
S
T
A
T
&
H
E
A
T
RE
G
I
S
T
E
R
S
)
A
R
E
S
H
O
W
N
.
2.
RE
L
O
C
A
T
E
D
E
X
I
S
T
I
N
G
E
L
E
C
T
R
I
C
A
L
F
I
X
T
U
R
E
S
AR
E
N
O
T
E
D
.
3.
EX
I
S
T
I
N
G
E
L
E
C
T
R
I
C
A
L
F
I
X
T
U
R
E
S
O
N
D
E
M
O
WA
L
L
S
T
H
A
T
A
R
E
N
O
T
R
E
L
O
C
A
T
E
D
A
R
E
T
O
B
E
AB
A
N
D
O
N
E
D
.
4.
RE
M
O
V
E
A
L
L
H
U
M
I
D
I
F
I
C
A
T
I
O
N
U
N
I
T
S
&
T
H
E
I
R
CO
N
T
R
O
L
S
.
5.
AL
L
E
X
I
S
T
I
N
G
H
E
A
T
R
E
G
I
S
T
E
R
S
A
R
E
T
O
B
E
RE
P
L
A
C
E
D
W
/
N
E
W
H
E
A
T
R
E
G
I
S
T
E
R
S
O
F
T
H
E
SA
M
E
H
E
A
T
I
N
G
C
A
P
A
C
I
T
Y
.
receptacle