HomeMy WebLinkAboutB12-0461 ELECTRICAL LOAD CALCS
This is a Electrical Load report for the Vail Community
Development Office for the remodel at Vail Racquit Club
Building 11 Unit 8. I am the electrician working for No
Bull Contracting. My company is Eagle Electric Inc. and
my name is Michael Koenen.
The property has multable apartments. The remodel has its own meter. The
meter has a 100 amp main breaker. The feeder to the panel is a 1/0 SER wire
from the meter.
The only power requirements we are adding are 2 additional recessed
lights in the bedroom. The 2 recessed cans with 22 watt fluorescents . The
change in watts is 44.
The bathroom will have a new fan light. No change in wattage.
We will move some light switches to the bathroom because the door
will change.
650 sq.ft.*3VA per sq ft. 1950VA
3000VA at 100% 1950VA
General Lighting….. 1950VA
Small appliance load 3000VA
Laundry 1500VA
Total General lighting
And small appliance 6450VA
Range load 8000VA
Dryer load 5500VA
Total Load 19950 divided by 240V.=83 amps
My is Michael Koenen and my company is Eagle Electric Inc.
from Box 131, Gypsum CO 471-6155