HomeMy WebLinkAboutB12-0462NOTE: TH/S PERMIT MUST BE POSTED ON JOBS/TE AT ALL TIMES
, �•
������ �
Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657
p. 970.479.2139, f. 970.479.2452, inpsections 970.479.2149
COMBINATION BLDG PERMIT Permit #: B12-0462
Job Address: 400 E MEADOW DR VAIL
Location......: TYROLEAN CONDOS
Parcel No....: 210108252010
OWNER HERBERT A. TOBIN AMENDED AND 09/19/2012
1101 HILLCREST DR
HOLLYWOOD, FL
330217845
Project #: PRJ 12-0571
Applied.....: 09/19/2012
Issued. . . : 09/27/2012
APPLICANT CONTRACTORS GENERAL LLC 09/19/2012 Phone: 970-376-6541
PO BOX 2373
VAI L
CO 81658
License: C000003246
CONTRACTOR CONTRACTORS GENERAL LLC 09/19/2012
PO BOX 2373
VAI L
CO 81658
License: C000003246
Phone: 970-376-6541
Description:
COMMON ELEMENT: MOVING THE ELEVATOR EQUIPMENT ROOM.
Occupancy: R-2 Type Construction:
Valuation: $60,000.00
................................................................................. FEE SUMMARY ...............................................................................
Building Permit -----------> $713.75 Bldg Plan Check ----------> $463.94 Use Tax Fee-----------------------> $1,000.00
Electrical Permit ---------> $115.00 Elec Plan Check -----------> $74.75 Restuarant Plan Review--------> $0.00
Mechanical Permit ------> $1,060.00 Mech Plan Check ---------> $265.00 Additional Fees--------------------> $O.00Plumbing Permit
--------> $0.00 Plmb Plan Check ---------> $0.00 Recreation Fee--------------------> $0.00
Investigation-----------------------> $0.00
Will Call------------------------------> $15.00
TOTAL PERMIT FEES--------------> $3,707.44
Payments-------------------------------> $3,707.44
BALANCE DUE------------------------> $0.00
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DECLARATIONS
I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure
according to the town's zoning and subdivision codes, design review approved, International Building and Residential Codes and
other ordinances of the Town applicable thereto.
REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149
OR AT OUR OFFICE FROM 8:00 AM - 4:00 PM.
combination permit_012811
�
�' � �
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CONDITIONS OF APPROVAL TO BE MET PRIOR TO FINAL SIGN OFF
Permit #: B12-0462 Address: 400 E MEADOW DR VAIL
Owner: HERBERT A. TOBIN AMENDED AND RESTATED RE
Location: TYROLEAN CONDOS
combination permit_012811
�
�
* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *
REQUIRED INSPECTIONS AND STATUSES
Permit #: B12-0462
Owner: HERBERT A. TOBIN AMENDED AND RESTATED RE
Location: TYROLEAN CONDOS
Address: 400 E MEADOW DR VAIL
* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *
Item: 00030 BLDG-Framing
Item: 00060 BLDG-Sheetrock Nail
Item: 00070 BLDG-Misc.
Item: 00120 ELEC-Rough
Item: 00200 MECH-Rough
Item: 00190 ELEC-Final
Item: 00390 MECH-Final
Item: 00090 BLDG-Final
combination permit_012811
�
�aw�u oF va�t
DeparEment of Community Development
` 75 South Frontage Road
Vail, CO 81657
� Tel: 970-479-2128
www.vaiigov.com
Development Review Coordinator
BUILDING PERMIT APPLlCATION
(Separate applications are required for alarm & sprinkier)
__ _ _ __ _ __ _ ._
Project Street Address: Project #: ���- l�� �
; � , � f .t..��,u S
f (Number) (Street) (Suite #)
�--
Building/Complex Name: ��/� � ''z�-ti
Contractor Information
; Business Name: C.:r>c�=� ��L-/�J�--j (.� ��'�� LLC:
Business Address: /". 'l✓ , i�S �X 2-3 73
; Ciry _ ��.�� / _ State: �n Zip: �/� S �
' Contact Name: /� c+��J C.7�- i.� L-T ��
' Contact Phone: 9' 7n � 3 7 6-� f ��
!� Contact E-Mail: �,t�L-/� /._ !i'�+'1 � ne/ Z�-��: L�`
I hereby acknowledge that I have read this application, filled out
in full the information required, completed an accurate plot plan,
and state that all the information as required is correct. I agree to
comply with the information and plot plan, to comply with all Town
ordinances and state laws, and to build this structure according to
the town's zoning and subdivision codes, design review ap-
proved, Intemational Building and Residential Codes and other
ordinances of the Town applicable thereto.
�
Owner/ wner's R presentative Sig ure (Required)
�Ulii'
Building Permit #: �� d� - �i � � �
Lot #: Block #� Subdivision: 1%/�I ll UI CL f}�(rC-
�1 L
Work Class: New ( ) Addition ( ) Alteration{�) '
Type of Building:��� .._� .�w _ ��� _a � _.��... _,�.� __._..�n_„�,��
(
Single-Family ( ) Duplex ( ) Multi-Family � ) �
Commercial ( ) Other ( ) E
_ _---- __ __ ___ .- _._. . _.__ _. _.. _ `
_ -- _ �
Work Type: Interior (
Work Included
_ _._ _. __.. --;
) Exterior (�' Both ( ) ;
i
--_____ ___-_—' ------ -----------�-,
Valuation of �
Plans Included Work !
es (�Ulvo l )Yes
Mechanical ( j�Yes (�Tlo �s- ( )No� 3 pp
Plumbing ( )Yes ( )No ( )Yes ( )No
Building (�Yes ( )No (�Yes ( )No S, DOp �
�
Value of all work being performed: ���$ �� �� `�
�value based on IBC Section 109.3 & IRC Section 108.3�
Electrical Square Footage
Applicant Information � Detailed Scope and Location of Woric:
Applicant Name: /Cc�.y �,�n-��J � a. f��•! E', j�-
, C1,.E�/ A i 0 iZ.
Applicant Phone: ���� �-��vVa.- I
I
Applicant E-Mail: S�� �-/�v V�._. i
! Project Information�
` Owner Name: / y� �E�-.�. �4's� � Ot,[9�ev G�
;Parcel#: 2/d / O �2.�Z0`O —OL-7
`(For Parcel #, contact Eagle County Assessors Office at (970-328-8640 or visit
� www.eaglecounty.uslpatie)
For Office Use Only:
Fee Paid:
Received From:
Cash Check #
CC: Visa / MC Last 4 CC #
Auth #
exp date:
Date Received:
�G �
���7, � •gn ��Zu
�0
ai
:a
_ �r
� CONTROLLER �
� 2�-9%2
PLAN
EP POWER UNlTS
MODEL TANK CAP A
GALS
EP-60 60 2-9,
EP-70
_ _ 66 . 2=9�
B C D E
3�-0'�• 3-2�� 73�4� 2� 7�
3-0 , 3'-lON 73/4 3� 3�
EP-150 75 2=9%'2' 3�-8
EP-170 106 2'-9�'`3-8
EP-190
3-2N � 73/4� �L� 7
3�-10��� 73/4�
NOTES: i, TANK SIZE IS SELECTED USING TOTAL GAL-
LONS REQ�D.70 DISPLACE P�UNGER PLUS IOqo.
2. MAXIMUM WORKING PRESSURE IS 500 P.S.I.
3. MINIMUM MACHINE ROOM DOOR SIZE 3�-0� W. x
7� 0'�H.
4. FOR WElGHT SEE SHEET I-N-6.
5. FOR PIPING SEE SHEETS I-N-3 d 4.
6. REDUCED VOLTAGE STARTING WITH C�OSED
TRANSITION REQUIRES TWO CONTROLLER
CABINETS. ONE IS MOUNTED ON THE POWER UNIT
AND IS PER OU�t STANOARD, THE SECAND IS
WALL MOUNTED WtTH DIMENSIONS OF 2� 6" W.
x 4'-0� H. ,c 10� C.
7. EMERGENCY POV�ER LOVYERING BATTERY TYPE
REQUIRES TWO CABINETS. ONE IS MOUNTED ON
THE POWER UNIT ANO IS PER OUR STANDARD,
THE SECOND IS WA�L MOUNTEO WITH DIMENSIONS
OF I'-33/4" W. : Z=3° H. x I I� D. AND HOUSES BATTERY
ETC. CALL FOR A 4-POLE DISCONNECT SWITCH
OR ONE WITH AN AUXILIARY CONTACT ON LAYOUT.
8. JO85 WITH COMPU7AMATIC�OPERATION REQUIRES
ONE COMPUTAMATIC� PANEL WA�L MOUNTED, PER
GROUP WITH ��MENSIONS PER STANDARO
CONTROLLER PANEL AND IN ADOITION TO
STANDARD CONTROLLER PANEl.S. IF JOB HA5
BACK WIRING SEE SNEET I-F-3.
CONTROLLER
�o
I
Q
�
_
c� —
iw
zz�
►�-w'n
.. w -'
F 1 G
2" � 3-3�
�
�
t1)
_i
�
'F� PIPE SIZE— J
`w
:.�.:� a.,..;..z::-='.._ ......... ,<,. , ,
FRONT VIEW
CONTROLLER CL.EARANCE
2� 3�3� 3'-6'� (4'-Ou WHEN
ELEC. PANELS FACE
2" 3�-I I%2 EACH OTHER 1
CLEAR REQ'D.
2" 3'-I I�/2
9. WHEN TANK CAPACITY REQUIRED ON A JOB
EXCEEDS 86 GALLONS ON EP-60-95 UNITS USE
THE 106 GALLON TANK AND USE �B;�C; AND �G'
DIMENSIONS FOR THIS TANK.
WHEN TANK CAPACITY REQUIRED EXCEc'DS 106
GA��ONS ON EP-125-190 UNITS CONSULT
HORN LAKE C.O.E. DEPT.
10. WHEN NEMA 4, 7, OR 12 CONTROLLER IS REQ�D.
OR IF TANDEM TANKS ARE REQ'Q CONSULT
HORN �AKE C.0.E. DEPT.
II. TO FIGURE THE HEAT LOAO IN THE MACHINE
ROOM SEE SHEET I-N-S.
DO NOT SCALE f i i �• �yQp
TH15 ORAWING i �� �� ��
OILORAULIC EP POWER UNIT
om.....,�,,.,,...,�.,�,.,,. �`��-I MANUAL I � ( N� 1.
�lV O�G YR �1
T�
HYpower
Job Name
Branch/Distributorq
Sales Representative
Up Speed
Capacity
Mainline Voitage
Existing Plunger diameter
Applicable Code
7yrolean
ROCMY MOUNTAIN / 179
Wlliam Daugs
� ' 125, �
' i500_ _
°, 208 VAC�3 Rl�ese) - <
, 4,36D
RNSI,2CI07
Number of Elevators in Group ��
Stops �; . �_J
Front Openings 4
Estimated Travel
Car Weight
Existing HP
ExisGng Jack Type
Price Per Elevator (wirh aptions)
Total Net Price per Group
GPM requued tor Up Speed 97 Optlonal Power Unit Model EP 95
Calculated Horsepower Low Pressure Check
Actual Up Speed 172 FPM High Pressure Check
If setected, the new Power Unit(s) will be designed per Caltulated HP: ZO
Power Feeders rtsay be afiected _.
15:R .
TAC 32 ConUOI system (includes Standard Features plus the foilowing:)
Soiid State Starter Auto Fan and Light
Battery Lowerinfl Vscosity Control (ncluded when selected on Options Page)
On Board Diagnostic Tool VISTA Remote Monimring
Tenant Securiry 3-1 Owners Manuals and Job Specific Prints
Tape Se�ector system w/ Steel Tape 8 Mounting Hardware for leveling and limits (final Iimit not induded)
Wirin9 Package
Traveling Cahle and Hoistway wiring including SF2 ca61e for interlocks
{Hoistway DuCt klt pn be added on the Op6ons Tab, it is not included in the base)
Main Car Station with Required Features
ADA compliant
Applied panel, d4 Stainless Steel (Column type Swing available on Options page) '
Standard Features
CE EleCCronic position indfcator (Red)
ADA phone
Emergenty Light system with test button
Car TreveGng Larrtern (1 included)
HaIlStations (Fusion Surtace MounUed with Appendix 0)
Hoistway Access Key Switches (Flush mounted stations or mounted in hall station)
Car Top Exit Switch
Door Eqwpment upgrede induding Mechanical Restrictor kit (Select one below)
� HD-04 Doa Operator with Drive Arm Adapter and Mounting PWte
O HD-0A Door Operator with GAL Adapter Wheel (if reusing exisdng GAL Equipmenq
(This option is only available for Left Hand Side Opening and Center Opening applications)
O SmartTech II Motor & Board kit (n lieu of HD-04)
Janus Model 6A0 Edqe detector
Reuse Existing power unii
s ia. �,r► .. ,�. �
s
..
Up Speed: 122
Capaciry: 1500
Voltage: 208VAC (3 Phase)
Jack Sae: 4.360
Applicabie Code: ANSI 2007
Options Page
Number of Eleva[ors: 1
Stops: 4
Front Openings: 4
Trevel: 31
Existing HP: 15
Car Weight: 1,680
New Pawer Unit EP 95
H P to be Provided 20
Pipeline Trevel 20
Gallons of Oil Requi�ed 105
Net Options Price per Elevator:� _.�
1 p 21' Tce Guard
1 O 4' Car Raller Guides forT-Rails (indudes guide shoe maxiting plates and baiance weight frame)
1 � CarTop Railing
12 � Submersible Power,Unit (I-2 Valve, 80 Starts per hour) (indudes Oil)
20 � FT <- Enter pipeline distance fran power unit outlet to jack inlet
Gallons <- Oii (standar� included for application
`"'�;1 ?66;��' Gallon <- Tank Size required for application
12 D 2" Shutoff Valve Kit OTY: '': > 1: `'
1 z O 3" Shutoff Valve Kit QTY: 0
lZ ❑ Isolaiion Couplings �n' �
lZ � Over Speed Valve Kit 2" (less than 150GPM)
12 O Over Speed Valve Kit 3' (over 150 GPM)
i� O Seismic Requirements for EP Units
12 ❑ Biodegredable Oil Add
12 O �scosity Control
19
18
22
22
22
O OpBonal Stainless Steel Selector Tape
❑ Hoistway Dud Kit
O Add for Swing COP (Match e�usting Dover/rKE onry) Please include photos of existing
O Add (or Microban Antimiao6ial Protection Kit (Tl buttons onfy)
p Additional Car Riding Lantem
23 C) Hoistway Jamb Braille (at all floors)
23 0 Car 1D Plate (Jamb mounted at Maln Egress�
23 O Fusion Ha0 Digital PI's (Cf) �TY: 0 Fnish will be #4 S/S, Red LED's
Z3 O Fusion Hap Lantem & Chime QTY. 0 Finish will be �4 S/S
23 � Fusion HaU Combo PIlLantem QTY: d' Finish will be Y4 SlS, Red LED's
�3 O Pit Stop Switch an'� 1
?6 O Pit Ladder
�G �
I �/2p }-- •B� --i I �/2 �
I I
:a
�
�Q -
�
' -c�
� �
a CONTROLLER �
2-9%2�
PLAN
EP POWER UNITS
MODEL TANK CAP A
GALS
EP-60 60 2-9
EP-70
-- -- - 86 2=9
EP-150 75 2
EP-170 106 2'-
EP-190
6 C D
3�-0'�• 3- 2�� 73�4N 2�-
3-0 3'-IOu 73/4 3=;
��
'-8�/2 3 -2� 73/4" � '
CONTROLLER
`o
�
Q
�
_
c� -
w
2 w
Z z M
f-Q- w 't'�
.. w --
'F� PIPE SIZE—
�
�
�
_i
�
'w
- ,�:: .- ... , :.�-.. .. .. . . ...... ...._ .:.... .: � . .
FRONT VIEW
E F G CONTROLLER CI.EARANCE
7�4 2� 3-3'
S3/4 2� 3=3� 3'-6'� (4'-0° WHEN
ELEC. PANELS FACE
'3klN 2" 3�-I I%2 EACH OTHER )
CLEAR REQ�D.
-8�/2� 3-10��� 73/4� �3� 33/4I 2� �3'-I
NOTES: I. TANK SIZE IS SELECTED USING TOTAL GAL-
LONS REQ'D. TO DISPLACE PLUNGER PLUS 10°l0.
2. MAXtMUM WORKING PRESSURE IS 500 P.S.I.
3. MINIMUM MACHINE ROOM DOOR SIZE 3�-0° W. x
7 � 0�� H.
4. FOR WEI�HT SEE SHEET I-N-6.
5. FOR PIPING SEE SHEETS I-N-3 d 4.
6. REDUCED VOLTAGE STARTING WITH CLOSED
TRANSITION REQUIRES TWO CONTROLLER
CABINETS. ONE IS MOUNTED ON THE POWER UNIT
AND IS PER OUti STANDARD, THE SECAND IS
WALL MOUNTED WITH DIMENSIONS OF 2� B" W.
x 4�-0� H. z 10� C.
7. EMERGENCY POV�ER LOWERING BATTERY TYPE
REQUIRES TWO CABINETS. ONE IS MOUNTED ON
THE POWER UN1T ANO IS PER OUR STANDARO,
THE SECOND IS WALL MOUNTED WITH DIMENSIONS
OF I'-33/4" W. : 2' 3" H. x I I� D. AND HOUSES BATTERY
ETC. CALL FOR A 4-POI.E DISCONNECT SWITCH
OR ONE WITH AN AUX[LI,4RY CONTACT ON LAl'OUT.
8. JOBS WITH COMPUTAMATIC�OPERATION REQUIRES
ONE COMPUTAMATIC� PANEL WALL MOUNTED, PER
GROUP WITH DIMENSIONS PER STANDARD
CONTROLLER PANEL AND IN ADDITION TO
STANOARD CONTROLLER PANELS. ►F JOB HAS
BACK WIRING SEE SHEET I-F-3.
om...r„ar..... ��.�....,,.�
9. WHEN TANK CAPACITY REQUIRED ON A JOB
EXCEEDS 86 GALLONS ON EP-60-95 UNITS USE
THE 106 GALLON TANK AND USE +B;�C; AND �G'
DIMEN510N5 FOR TH15 TANK.
WHEN TANK CAPACITY REQUIRED EXCEEOS 106
GALLONS ON EP-12�190 UNITS CONSUIT
HORN LAKE C.O.E. DEPT.
10. WFiEN NEMA 4, 7� OR 12 CONTROLLER l5 REQ�D.
OR IF TANDEM TANKS ARE REQ'0. CONSULT
FtORN LAKE C.O.E. DEPT.
II. TO FIGURE THE HEAT LOAD IN THE MACHINE
ROOM SEE SHEET I-N-S.
'J-d R�T DO NOT SCALE i i �• �yQp�
,q�T- THIS DRAWING �� ��x �
�T OILDRAULIC EP POWER UNIT
f I RLT
LA UT R��•T R-L.R. �b+t-!J
����T MAN UAL 1 N 1.2 F
...
� i • • . 1i
!
••
Job Name Tyrolean
Branch/Distributor k ROCM,Y MOUNTAIN / 179
5ales Representa6ve William Daugs _
Up 5peed � 125. i- � i
Capacity � i500 _ : '
Mainline Voltage 208 YAC (3 @hase�
Existing Plunger diameter � 4,:SS0�
Applicable Code � ANs12007
Number of Elevators in Group
Stops
Front Openings
Estimated Travei
Car Weight
Existing HP
Existing JackType
L�;_�
4
`31 :^_�
1680
t5.Q
Conventional
Price Per Elevator (with optionsl �
Total Net Pnce per Group �
GPM required fot Up Speed 97 Optional Power Unit Modei EP 95
Calculated Horsepower Low Pressure Check
Actual Up Speed 122 FPM High Pressure Check
If selected, the new Power Unit(s) will be designed per Caltulated HP: 20
Power Feeders may be affected __
TAC 32 ConUOI sys[em (includes Standard Features plus the following:)
Solid State Slarter Auto Fan and Light
Battery Lowering Yscosity Control (ncluded when selected on Options Page)
On Board Diagnostic Taol VISTA Remote Monitoring
Tenant Security 3-1 Owners Manuals and Joh Specific Prints
Tape Selector system w/ Steel Tape 8 MounGng Hardware (or leveling and limits (final limR not induded)
�ring Package
TravHing Ca61e and Hoistway wiring including SF2 table tor interlocks
(Hoist4vay Ouct klt can be added on the Op6ons Tab, it is not induded in the base)
Main Car Sta6on with Required Features
ADA compliant
Applied panel, Y4 Stainless Steel (Column type Swing available on Options page)
Standard Features
CE Electronic position indiwtor (Red)
ADA phone
Emergency Light sysiem with test button
CarTreveGng Lantern (1 in�luded)
Hall Stations (Fusion Surtace Mounted with Appendix 0)
HoisMray Access Key Switrhes (Flush mounted stations or mounted in hafl staUon)
Car Top Exit Switch
Door Equipment upgrade induding Mechanical Restridor kit (Select one below)
O HD-Q4 Door Operator with Drive Arm Adapter and Mounting Plate
O HD-04 Door Operator wim GAL Adapter Wheel (if reusing exis6ng GAL Equipmenq
(TYiis option is only available �or Left Hand Side Opening and Center Opening applications)
O SmartTech II Motor & Board kit (in lieu of HD-04)
Janus Model 640 Edge detector
Reuse Existing power unit
Up Speed: 122
Capacity: 1500
Voltage: 208 VAC (3 Phase)
Jadc S¢e: 4.360
Applicable Code: ANSI 2007
HYpower
Options Page
Number of Eleva[ors: 1
Stops: 4
Front Openings: 4
Travel: 31
Ewsting HP: 15
Car Weight: 1,680
New Power Unit EP 95
H P to be Provided 20
Pipeline Trevel 2Q
Gallor�s of Oil Required 105
Net Options Price per Elevator:j �
1 p 21' Tce Guard
1 � 4" Car Roller Guides forT-Rails (indudes guide shoe mamt�g plates and balance weigM Frame)
1 O CarTop Railing
12 O Submersible Power,Unit (I-2 Valve, SO Starts per hour) (indudes Oil)
�zD 1 <- Enter pipeline distance from power unit outlet to jack iNet
�iions <- Oil (standarcn included fir application
°'66 `� . i: allon <- Tank Size required for appliration
12 D 2" Shutoff Valve Kit QTY: 1.
12 ❑ 3" ShutoffValve Kit QN: ' 0`-
12 ❑ Isolaiion Couplings �n' �
12 O Over Speed Valve Kit 2' (less tfian 150GPM)
12 ❑ Over Speed Valve Kit 3' (over 150 GPM)
12 O Seismic Requirements for EP Units
12 O Biodegradable Oil Add
12 O �scosity Control
19
18
22
22
22
D Optlonal Stainless Steel Selector Tape
❑ Hoistway Duct Kit
O Add for Swing COP (Match existing Dover/TKE only) Please include photos of ebsting
p Add for Microban Antimiaohial Protection Kit (f 1 buttons only)
❑ Additional Car Riding Lantern
23 � Hoistway Jamb Braifle (at all floors)
23 O Car ID Plate (Jamb mounted at Main Egress�
23 ❑ Fusion HaA Digital PI's (CE) �7'f: 0 Fnish will he #4 S/S, Red LED's
23 O Fusion Ha� Lantem & Chime QiY. 0 Finish will be U4 S/S
23 O Fusion Hall Combo PIlLantem QTYc d Finish will be #4 S/S, Red LED's
?3 O Pit Stop Switch Q�'� 1
26 O pic Ladder
�G �
.„ .
� �/?" B ---� j I �/2N
I
,a
R'
=Q "—
.
cv �
Q CONTROLLER
� 2�-912�
PLAN
EP POWER UNITS
MODEL TANK CAP A
GALS
EP-70 1 60 2-9
8 I C
CONTROLLER
�o
�
'v
�
2
c? —
2 w
Z Z �
�w'n
, . w -_
D! E I F I G
3�-0'�•� 3-2" { 73�4� �2�-7�4� 2� � 3-3�
66�2=9�����r0�'i 3�-IO��I 73/4 I3� 3314�I 2� � 3-3�
t�-�« 75 2� 9�"3-8�/2 3-2" 73/4"
EP-150
EP-170 106 2'-9�"3-8%2 3-10° 73/4"
EP-190
NOTES: I. TANK SIZE IS SELECTED UStNG TOTAL �A�
LONS REQ�D. TO DISPLACE PLUNGER PLUS IOqo.
2. MAXIMUM WORKING PRESSURE IS 500 P.S.I.
3. MINIMUM MACHINE ROOM OOOR SIZE 3�-0° W. �
7=0'� H.
4. FOR WEIGHT SEE SHEET I-N-6.
5. FOR PIPING 5EE SHEETS I-N-3 d 4.
6. REDUCED VOLTAGE STARTING WlTH CLOSED
TRANSITION REQUIRES TWO CONTROLLER
CABINETS. ONE IS MOUNTED ON THE POWER UNIT
AND IS PER OU� STANOARD, THE SECAND IS
WALL MOUNTED WITH DIMENSIONS OF 2� 6" W.
x 4'-0� H. x 10� C.
7. EMERGENCY POV�ER LOWERING BATTERY TYPE
REQUIRES TWO CABINETS. ONE IS MOUNTED ON
THE POVYER UNIT AND IS PER OUR STANDARO,
THE SECOND IS WALL MOUNTED WITH DIMENSIONS
OF I'-33/4"W.: Z' 3°H.: I I� D. AND HOUSES BATTERY
ETC. CALL FOR A 4-POLE DlSCONNECT SWITCH
OR ONE WITH AN AUXILIARY CONTACT ON LAYOUT.
8. JOBS WITH COMPUTAMATIC�OPERATION REQUIRES
ONE COMPUTAMATIC' PANEL WA�� NtOUNTED, PER
GROUP WITH �►MENSIONS PER STANDARO
CONTROLLER PANE� AND IN AODITION TO
STANDARD CONTROLLER PANELS. IF JOB HAS
BACK WIRING SEE SHEET I-F-3.
2"
2Y
�
�F� PIPE SIZE—II�
'w
�
�
�
i
_�
...... : :.:•_�. . .
FRONT VIEW
CONTRO��ER CLEARANCE
3'-6'� (4'-0" WHEN
ELEC. PANELS FACE
EACH OTHER f
CLEAR REQ'D.
9. WHEN TANK CAPACITY REQU�RED ON A JOB
EXCEEDS 86 GALLONS ON EP-60-95 UNITS USc
THE 106 GAI.LON TANK AND USE �B,�C; ANO �G�
DIMENSIONS FOR TH15 TANK.
WHEN TANK CAPACITY REQUIRED EXCEc'OS 106
GAL�ONS ON EP-125-190 UNITS CONSU�T
HORN LAKE C.O.E. DEPT.
f0. WHEN NEMA 4, 7, OR 12 CONTROLLER l5 REQ�D.
OR IF TANDEM TANKS ARE REQ'0. CONSU�T
HORN �AKE C.O.E. DEPT.
II. TO FIGURE THE HEAT LOAO IN THE MACHINE
ROOM SEE SHEET I-N-S.
00 NOT SCALE I i i �• Fl FYQp(�
TH15 DRAWING �� i�� �
OILORAULIC EP POWER UNIT
om...�,m,.,�.. �K."�.". � �-,_� K" MAN UAL i� I N I 1.2 �F
w�V. �m1G Yt[ w
TK
HYpower
Job Name
Branch/Distributor q
Sales Representadve
Up Speed
Capacity
Mainline Voltage
Existing Plunger diameter
Applicable Code
Tyrolean
ROCM,Y MOUNTAIN / 179
William Daugs
125
1500' 1
208 YAC t3 Phssel _.
s■
eA
Number of Elevators in 6roup ��
Stops LU�,_•..J
Front Openings 4
EstimatedTrevel 31 ;:�
Car Weight �
Existing HP �
Existing JackType = CBrN1ea
Price Per Elevator (with apdor�s) �
Total Net Price per Group �_
GPM required for Up Speed 97 Optlonal Power Unit Model E
Calwlated Horsepower Low Pressure Check
Actual Up Speed 171 FPM High Pressure Check
If selected, the new Power Unit(s) will be designed per Calculated HP: ZO
Power Feeders may 6e affected , -.
TAC 32 Convol system (includes Standard Features plus the following:)
Solid State Starter Auto Fan and Light
Battery Lowerinp Vscosity Control (included when selected on Options Page)
On Board Diagnosuc 7o01 VISTA RemoOe Monitoring
Tenant Security 3-1 Owners Manuals and Job Specific Prints
Tape Selector system w/ Stecl Tape & Mounting Hardware for leveling and limits (final limR no[ induded)
�ring Package
Traveling Cable and Hoistway wiring including 5F2 ca61e for interlOCks
(Hoistway Duct kit pn be added on the Opoons Tab, it is not included in the base)
Main Car Sbtion wiYh Required Features
ADA compliant
Applied panel, Y4 Stainless Steel (Column type Swing available on Opiions page)
Standard Features
CE Elearonic position indicator (Red)
ADA pho�e
Emergency Light system with test button
CarTraveGng Lantern (1 included)
Hall Sbtions (Fusion Surtace MounLed wlth Appendix 0)
HoisMray Access Key Switches (Flush mounted stetions or mounted in haii staUon)
Car Top Exit Swihh
Door Equipment upgrede induding Mechanical Restrictor kit (Select one below)
O HD-04 Door Operator with Drive Arm Adapter and Maunting Plate
O HD-04 Door Operator with GAL Adapter Wheel (if reusing existlng GAL Equipmenq
(This option is only a�ailable for LeR Hand Side Opening and Center Opening applications)
O SmartTech II Motor & Board kit (in lieu of HDA4)
Janus Model 640 Edqe detector
Reuse Existing power unit
Up Speed: 1Z2
Capacity: 1500
Voltage: 208 VAC (3 Phase)
Jadc S¢e: 4,360
Applicabie Code: ANSI 2007
HYpower
Options Page
Number of Elevators: 1
Stops: 4
Fro�t Openings: 4
Travel: 31
Existing HP: 15
Car Weight: 1,680
New Power Unit EP 95
HP to be Provided 20
Pipeline Travel 20
Gallons of Oil Required 105
Net Options Price per E)evator:� -.�
1 O 21' ioe 6uard
1 O 4' Car Roller Guides forT-Rails (indudes guide shoe mounting plates and balance weight frame)
1 O CarTop Railing
12 � Submersible Power.Unit (I-2 Vaive, 80 Starts per hour) (indudes OiI)
�� T <- Enter pipeline distance from power unit outlet to jack iniet
�allons <- Oil (standar� included for application
' ��" �66;�:•�:�Gallon �-TankSizerequlredforapplication
12 D 2" Shutoff Valve Kit olY: 1:
12 ❑ 3' Shutoff Valve Kit Q1Y: -- 0< <
lZ ❑ Isolation Couplings �n' �
12 O Over Speed Vaive Kit 2" (less than 150GPM)
12 � Over Speed Valve Kit 3' (over 150 GPM)
12 O Seismic Requirements for EP Units
lZ O Biodegradable Oil Add
12 O �scosiry Control
19
18
22
22
22
D Optional Stainless Steel Selector Tape
❑ Hoistway Duct Kit
❑ Add for Swing COP (Metch e�usting Dover/rKE ony) Please include photos of epsting
O Add for Microban Antimiaobial Protection Kit (Tl buttons only)
❑ Additional Car Riding Lantern
23 fO Hoistway Jamb Braille (at all tloors)
23 O Caf ID PIBtB (Jamb mounted at Main Egress)
z3 � Fusion Ha9 Digital PI's (CE) �TY: 0: Fnish will be #4 S/S, Red LED's
23 O Fusion Nau Lantem & Chime QTY. Q Finish will be 84 S/S
23 O Fusion Hau Combo PI/Lantern OTY: d Finish will be #4 S/S, Red LED's
z3 O Pit Stop Swicch aT1'. 7
?6 � Pit Ladder
„ , .
0-29-201
..,,, _.Y
Inspection
v��i
orting
Requested Inspect Date: Tuesday, October 30, 2012
Site Address: �RO E NDC� N OSAIL
Page 20
A/P/D Information
Activity: 612-0462 Type: COMBO Sub Type: OTHER Status: ISSUED
Const Type: Occupancy : Use: R-2 Insp Area:
Owner: HERBERT A. TOBIN AMENDED AND
RESTATED RE Phone: 970-376-6541
Contractor: CONTRACTORS GENERAL LLC
Description: COMMON ELEMENT: MOVING THE ELEVATOR EQUIPMENT ROOM.
Requested Inspection(sl
item: 90 BLDG-Final
Requestor: CONTRACTORS GENERAL LLC
Comments: 376-65
Assigned To: J O AGON
Action: Time Exp:
Item: 190 ELEC-Final
Requestor:
Comments: 471-061
Assigned To: J ON
Action: Time Exp:
Item: 390 MECH-Final
Requestor: CONTRACTORS GENERAL LLC
Comments: 376-654
Assi ned To� J O GON
Requested Time: 10:00 AM
Phone: 970-376-6541
Entered By: JMONDRAGON K
Requested Time: 08:00 AM
Phone:
Entered By: MHAEBERLE K
Requested Time: 09:30 AM
Phone: 970-376-6541
Entered By: JMONDRAGON K
9 Action: Time Exp:
r
U��`� � �- � � 4 ��”
��
� c �
Inspection Historv
Item: 30 BLDG-Framing
10/16/12 Inspector:
Comment:
Item: 60 BLDG-Sheetrock Nail
10/18/12 Inspector:
Comment:
Item: 70 BLDG-Misc.
Item: 120 ELEC-Rough
10/16/12 Inspector:
Comment:
Item: 200 MECH-Rough
Item: 190 ELEC-Final
Item: 390 MECH-Final
Item: 90 BLDG-Final
*` Approved *"
sgremmer
"" Approved *`
sgremmer
** Approved'*
sgremmer
Action: AP APPROVED
Action: AP APPROVED
Action: AP APPROVED
REPT131 Run Id: 14618
*******************+**********************************+*************************************
TOWN OF VAIL, COLORADOCopy Reprinted on 01-02-2013 at 08:56:02 O1/02/2013
Statement
�********************************************«�*********************************************
Statement Number: R120001482 Amount: $3,243.53 09/27/201210:17 AM
Payment Method: Check Init: JRM
Notation:
-----------------------------------------------------------------------------
Permit No: B12-0462 Type: COMBINATION BLDG PERMIT
Parcel No: 2101-082-5201-0
Site Address: 400 E MEADOW DR VAIL
Location: TYROLEAN CONDOS
Total Fees: $3,707.44
This Payment: $3,243.53 Total ALL Pmts: $3,707.44
Balance: $0.00
+*********+*********************+**********************+**********+***********+*************
ACCOUNT ITEM LIST:
Account Code
BP 00100003111100
EP 00100003111100
MP 00100003111100
PF 00100003112300
UT 11000003106000
WC 00100003112800
Description
BUILDING PERMIT FEES
ELECTRICAL PERMIT FEES
MECHANICAL PERMIT FEES
PLAN CHECK FEES
USE TAX 40
WILL CALL INSPECTION FEE
Current Pmts
713.75
115.00
1,060.00
339.78
1,000.00
15.00
-----------------------------------------------------------------------------