Loading...
HomeMy WebLinkAboutB12-0462NOTE: TH/S PERMIT MUST BE POSTED ON JOBS/TE AT ALL TIMES , �• ������ � Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657 p. 970.479.2139, f. 970.479.2452, inpsections 970.479.2149 COMBINATION BLDG PERMIT Permit #: B12-0462 Job Address: 400 E MEADOW DR VAIL Location......: TYROLEAN CONDOS Parcel No....: 210108252010 OWNER HERBERT A. TOBIN AMENDED AND 09/19/2012 1101 HILLCREST DR HOLLYWOOD, FL 330217845 Project #: PRJ 12-0571 Applied.....: 09/19/2012 Issued. . . : 09/27/2012 APPLICANT CONTRACTORS GENERAL LLC 09/19/2012 Phone: 970-376-6541 PO BOX 2373 VAI L CO 81658 License: C000003246 CONTRACTOR CONTRACTORS GENERAL LLC 09/19/2012 PO BOX 2373 VAI L CO 81658 License: C000003246 Phone: 970-376-6541 Description: COMMON ELEMENT: MOVING THE ELEVATOR EQUIPMENT ROOM. Occupancy: R-2 Type Construction: Valuation: $60,000.00 ................................................................................. FEE SUMMARY ............................................................................... Building Permit -----------> $713.75 Bldg Plan Check ----------> $463.94 Use Tax Fee-----------------------> $1,000.00 Electrical Permit ---------> $115.00 Elec Plan Check -----------> $74.75 Restuarant Plan Review--------> $0.00 Mechanical Permit ------> $1,060.00 Mech Plan Check ---------> $265.00 Additional Fees--------------------> $O.00Plumbing Permit --------> $0.00 Plmb Plan Check ---------> $0.00 Recreation Fee--------------------> $0.00 Investigation-----------------------> $0.00 Will Call------------------------------> $15.00 TOTAL PERMIT FEES--------------> $3,707.44 Payments-------------------------------> $3,707.44 BALANCE DUE------------------------> $0.00 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DECLARATIONS I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the town's zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8:00 AM - 4:00 PM. combination permit_012811 � �' � � . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CONDITIONS OF APPROVAL TO BE MET PRIOR TO FINAL SIGN OFF Permit #: B12-0462 Address: 400 E MEADOW DR VAIL Owner: HERBERT A. TOBIN AMENDED AND RESTATED RE Location: TYROLEAN CONDOS combination permit_012811 � � * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * REQUIRED INSPECTIONS AND STATUSES Permit #: B12-0462 Owner: HERBERT A. TOBIN AMENDED AND RESTATED RE Location: TYROLEAN CONDOS Address: 400 E MEADOW DR VAIL * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * Item: 00030 BLDG-Framing Item: 00060 BLDG-Sheetrock Nail Item: 00070 BLDG-Misc. Item: 00120 ELEC-Rough Item: 00200 MECH-Rough Item: 00190 ELEC-Final Item: 00390 MECH-Final Item: 00090 BLDG-Final combination permit_012811 � �aw�u oF va�t DeparEment of Community Development ` 75 South Frontage Road Vail, CO 81657 � Tel: 970-479-2128 www.vaiigov.com Development Review Coordinator BUILDING PERMIT APPLlCATION (Separate applications are required for alarm & sprinkier) __ _ _ __ _ __ _ ._ Project Street Address: Project #: ���- l�� � ; � , � f .t..��,u S f (Number) (Street) (Suite #) �-- Building/Complex Name: ��/� � ''z�-ti Contractor Information ; Business Name: C.:r>c�=� ��L-/�J�--j (.� ��'�� LLC: Business Address: /". 'l✓ , i�S �X 2-3 73 ; Ciry _ ��.�� / _ State: �n Zip: �/� S � ' Contact Name: /� c+��J C.7�- i.� L-T �� ' Contact Phone: 9' 7n � 3 7 6-� f �� !� Contact E-Mail: �,t�L-/� /._ !i'�+'1 � ne/ Z�-��: L�` I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the town's zoning and subdivision codes, design review ap- proved, Intemational Building and Residential Codes and other ordinances of the Town applicable thereto. � Owner/ wner's R presentative Sig ure (Required) �Ulii' Building Permit #: �� d� - �i � � � Lot #: Block #� Subdivision: 1%/�I ll UI CL f}�(rC- �1 L Work Class: New ( ) Addition ( ) Alteration{�) ' Type of Building:��� .._� .�w _ ��� _a � _.��... _,�.� __._..�n_„�,�� ( Single-Family ( ) Duplex ( ) Multi-Family � ) � Commercial ( ) Other ( ) E _ _---- __ __ ___ .- _._. . _.__ _. _.. _ ` _ -- _ � Work Type: Interior ( Work Included _ _._ _. __.. --; ) Exterior (�' Both ( ) ; i --_____ ___-_—' ------ -----------�-, Valuation of � Plans Included Work ! es (�Ulvo l )Yes Mechanical ( j�Yes (�Tlo �s- ( )No� 3 pp Plumbing ( )Yes ( )No ( )Yes ( )No Building (�Yes ( )No (�Yes ( )No S, DOp � � Value of all work being performed: ���$ �� �� `� �value based on IBC Section 109.3 & IRC Section 108.3� Electrical Square Footage Applicant Information � Detailed Scope and Location of Woric: Applicant Name: /Cc�.y �,�n-��J � a. f��•! E', j�- , C1,.E�/ A i 0 iZ. Applicant Phone: ���� �-��vVa.- I I Applicant E-Mail: S�� �-/�v V�._. i ! Project Information� ` Owner Name: / y� �E�-.�. �4's� � Ot,[9�ev G� ;Parcel#: 2/d / O �2.�Z0`O —OL-7 `(For Parcel #, contact Eagle County Assessors Office at (970-328-8640 or visit � www.eaglecounty.uslpatie) For Office Use Only: Fee Paid: Received From: Cash Check # CC: Visa / MC Last 4 CC # Auth # exp date: Date Received: �G � ���7, � •gn ��Zu �0 ai :a _ �r � CONTROLLER � � 2�-9%2 PLAN EP POWER UNlTS MODEL TANK CAP A GALS EP-60 60 2-9, EP-70 _ _ 66 . 2=9� B C D E 3�-0'�• 3-2�� 73�4� 2� 7� 3-0 , 3'-lON 73/4 3� 3� EP-150 75 2=9%'2' 3�-8 EP-170 106 2'-9�'`3-8 EP-190 3-2N � 73/4� �L� 7 3�-10��� 73/4� NOTES: i, TANK SIZE IS SELECTED USING TOTAL GAL- LONS REQ�D.70 DISPLACE P�UNGER PLUS IOqo. 2. MAXIMUM WORKING PRESSURE IS 500 P.S.I. 3. MINIMUM MACHINE ROOM DOOR SIZE 3�-0� W. x 7� 0'�H. 4. FOR WElGHT SEE SHEET I-N-6. 5. FOR PIPING SEE SHEETS I-N-3 d 4. 6. REDUCED VOLTAGE STARTING WITH C�OSED TRANSITION REQUIRES TWO CONTROLLER CABINETS. ONE IS MOUNTED ON THE POWER UNIT AND IS PER OU�t STANOARD, THE SECAND IS WALL MOUNTED WtTH DIMENSIONS OF 2� 6" W. x 4'-0� H. ,c 10� C. 7. EMERGENCY POV�ER LOVYERING BATTERY TYPE REQUIRES TWO CABINETS. ONE IS MOUNTED ON THE POWER UNIT ANO IS PER OUR STANDARD, THE SECOND IS WA�L MOUNTEO WITH DIMENSIONS OF I'-33/4" W. : Z=3° H. x I I� D. AND HOUSES BATTERY ETC. CALL FOR A 4-POLE DISCONNECT SWITCH OR ONE WITH AN AUXILIARY CONTACT ON LAYOUT. 8. JO85 WITH COMPU7AMATIC�OPERATION REQUIRES ONE COMPUTAMATIC� PANEL WA�L MOUNTED, PER GROUP WITH ��MENSIONS PER STANDARO CONTROLLER PANEL AND IN ADOITION TO STANDARD CONTROLLER PANEl.S. IF JOB HA5 BACK WIRING SEE SNEET I-F-3. CONTROLLER �o I Q � _ c� — iw zz� ►�-w'n .. w -' F 1 G 2" � 3-3� � � t1) _i � 'F� PIPE SIZE— J `w :.�.:� a.,..;..z::-='.._ ......... ,<,. , , FRONT VIEW CONTROLLER CL.EARANCE 2� 3�3� 3'-6'� (4'-Ou WHEN ELEC. PANELS FACE 2" 3�-I I%2 EACH OTHER 1 CLEAR REQ'D. 2" 3'-I I�/2 9. WHEN TANK CAPACITY REQUIRED ON A JOB EXCEEDS 86 GALLONS ON EP-60-95 UNITS USE THE 106 GALLON TANK AND USE �B;�C; AND �G' DIMENSIONS FOR THIS TANK. WHEN TANK CAPACITY REQUIRED EXCEc'DS 106 GA��ONS ON EP-125-190 UNITS CONSULT HORN LAKE C.O.E. DEPT. 10. WHEN NEMA 4, 7, OR 12 CONTROLLER IS REQ�D. OR IF TANDEM TANKS ARE REQ'Q CONSULT HORN �AKE C.0.E. DEPT. II. TO FIGURE THE HEAT LOAO IN THE MACHINE ROOM SEE SHEET I-N-S. DO NOT SCALE f i i �• �yQp TH15 ORAWING i �� �� �� OILORAULIC EP POWER UNIT om.....,�,,.,,...,�.,�,.,,. �`��-I MANUAL I � ( N� 1. �lV O�G YR �1 T� HYpower Job Name Branch/Distributorq Sales Representative Up Speed Capacity Mainline Voitage Existing Plunger diameter Applicable Code 7yrolean ROCMY MOUNTAIN / 179 Wlliam Daugs � ' 125, � ' i500_ _ °, 208 VAC�3 Rl�ese) - < , 4,36D RNSI,2CI07 Number of Elevators in Group �� Stops �; . �_J Front Openings 4 Estimated Travel Car Weight Existing HP ExisGng Jack Type Price Per Elevator (wirh aptions) Total Net Price per Group GPM requued tor Up Speed 97 Optlonal Power Unit Model EP 95 Calculated Horsepower Low Pressure Check Actual Up Speed 172 FPM High Pressure Check If setected, the new Power Unit(s) will be designed per Caltulated HP: ZO Power Feeders rtsay be afiected _. 15:R . TAC 32 ConUOI system (includes Standard Features plus the foilowing:) Soiid State Starter Auto Fan and Light Battery Lowerinfl Vscosity Control (ncluded when selected on Options Page) On Board Diagnostic Tool VISTA Remote Monimring Tenant Securiry 3-1 Owners Manuals and Job Specific Prints Tape Se�ector system w/ Steel Tape 8 Mounting Hardware for leveling and limits (final Iimit not induded) Wirin9 Package Traveling Cahle and Hoistway wiring including SF2 ca61e for interlocks {Hoistway DuCt klt pn be added on the Op6ons Tab, it is not included in the base) Main Car Station with Required Features ADA compliant Applied panel, d4 Stainless Steel (Column type Swing available on Options page) ' Standard Features CE EleCCronic position indfcator (Red) ADA phone Emergenty Light system with test button Car TreveGng Larrtern (1 included) HaIlStations (Fusion Surtace MounUed with Appendix 0) Hoistway Access Key Switches (Flush mounted stations or mounted in hall station) Car Top Exit Switch Door Eqwpment upgrede induding Mechanical Restrictor kit (Select one below) � HD-04 Doa Operator with Drive Arm Adapter and Mounting PWte O HD-0A Door Operator with GAL Adapter Wheel (if reusing exisdng GAL Equipmenq (This option is only available for Left Hand Side Opening and Center Opening applications) O SmartTech II Motor & Board kit (n lieu of HD-04) Janus Model 6A0 Edqe detector Reuse Existing power unii s ia. �,r► .. ,�. � s .. Up Speed: 122 Capaciry: 1500 Voltage: 208VAC (3 Phase) Jack Sae: 4.360 Applicabie Code: ANSI 2007 Options Page Number of Eleva[ors: 1 Stops: 4 Front Openings: 4 Trevel: 31 Existing HP: 15 Car Weight: 1,680 New Pawer Unit EP 95 H P to be Provided 20 Pipeline Trevel 20 Gallons of Oil Requi�ed 105 Net Options Price per Elevator:� _.� 1 p 21' Tce Guard 1 O 4' Car Raller Guides forT-Rails (indudes guide shoe maxiting plates and baiance weight frame) 1 � CarTop Railing 12 � Submersible Power,Unit (I-2 Valve, 80 Starts per hour) (indudes Oil) 20 � FT <- Enter pipeline distance fran power unit outlet to jack inlet Gallons <- Oii (standar� included for application `"'�;1 ?66;��' Gallon <- Tank Size required for application 12 D 2" Shutoff Valve Kit OTY: '': > 1: `' 1 z O 3" Shutoff Valve Kit QTY: 0 lZ ❑ Isolaiion Couplings �n' � lZ � Over Speed Valve Kit 2" (less than 150GPM) 12 O Over Speed Valve Kit 3' (over 150 GPM) i� O Seismic Requirements for EP Units 12 ❑ Biodegredable Oil Add 12 O �scosity Control 19 18 22 22 22 O OpBonal Stainless Steel Selector Tape ❑ Hoistway Dud Kit O Add for Swing COP (Match e�usting Dover/rKE onry) Please include photos of existing O Add (or Microban Antimiao6ial Protection Kit (Tl buttons onfy) p Additional Car Riding Lantem 23 C) Hoistway Jamb Braille (at all floors) 23 0 Car 1D Plate (Jamb mounted at Maln Egress� 23 O Fusion Ha0 Digital PI's (Cf) �TY: 0 Fnish will be #4 S/S, Red LED's Z3 O Fusion Hap Lantem & Chime QTY. 0 Finish will be �4 S/S 23 � Fusion HaU Combo PIlLantem QTY: d' Finish will be Y4 SlS, Red LED's �3 O Pit Stop Switch an'� 1 ?6 O Pit Ladder �G � I �/2p }-- •B� --i I �/2 � I I :a � �Q - � ' -c� � � a CONTROLLER � 2-9%2� PLAN EP POWER UNITS MODEL TANK CAP A GALS EP-60 60 2-9 EP-70 -- -- - 86 2=9 EP-150 75 2 EP-170 106 2'- EP-190 6 C D 3�-0'�• 3- 2�� 73�4N 2�- 3-0 3'-IOu 73/4 3=; �� '-8�/2 3 -2� 73/4" � ' CONTROLLER `o � Q � _ c� - w 2 w Z z M f-Q- w 't'� .. w -- 'F� PIPE SIZE— � � � _i � 'w - ,�:: .- ... , :.�-.. .. .. . . ...... ...._ .:.... .: � . . FRONT VIEW E F G CONTROLLER CI.EARANCE 7�4 2� 3-3' S3/4 2� 3=3� 3'-6'� (4'-0° WHEN ELEC. PANELS FACE '3klN 2" 3�-I I%2 EACH OTHER ) CLEAR REQ�D. -8�/2� 3-10��� 73/4� �3� 33/4I 2� �3'-I NOTES: I. TANK SIZE IS SELECTED USING TOTAL GAL- LONS REQ'D. TO DISPLACE PLUNGER PLUS 10°l0. 2. MAXtMUM WORKING PRESSURE IS 500 P.S.I. 3. MINIMUM MACHINE ROOM DOOR SIZE 3�-0° W. x 7 � 0�� H. 4. FOR WEI�HT SEE SHEET I-N-6. 5. FOR PIPING SEE SHEETS I-N-3 d 4. 6. REDUCED VOLTAGE STARTING WITH CLOSED TRANSITION REQUIRES TWO CONTROLLER CABINETS. ONE IS MOUNTED ON THE POWER UNIT AND IS PER OUti STANDARD, THE SECAND IS WALL MOUNTED WITH DIMENSIONS OF 2� B" W. x 4�-0� H. z 10� C. 7. EMERGENCY POV�ER LOWERING BATTERY TYPE REQUIRES TWO CABINETS. ONE IS MOUNTED ON THE POWER UN1T ANO IS PER OUR STANDARO, THE SECOND IS WALL MOUNTED WITH DIMENSIONS OF I'-33/4" W. : 2' 3" H. x I I� D. AND HOUSES BATTERY ETC. CALL FOR A 4-POI.E DISCONNECT SWITCH OR ONE WITH AN AUX[LI,4RY CONTACT ON LAl'OUT. 8. JOBS WITH COMPUTAMATIC�OPERATION REQUIRES ONE COMPUTAMATIC� PANEL WALL MOUNTED, PER GROUP WITH DIMENSIONS PER STANDARD CONTROLLER PANEL AND IN ADDITION TO STANOARD CONTROLLER PANELS. ►F JOB HAS BACK WIRING SEE SHEET I-F-3. om...r„ar..... ��.�....,,.� 9. WHEN TANK CAPACITY REQUIRED ON A JOB EXCEEDS 86 GALLONS ON EP-60-95 UNITS USE THE 106 GALLON TANK AND USE +B;�C; AND �G' DIMEN510N5 FOR TH15 TANK. WHEN TANK CAPACITY REQUIRED EXCEEOS 106 GALLONS ON EP-12�190 UNITS CONSUIT HORN LAKE C.O.E. DEPT. 10. WFiEN NEMA 4, 7� OR 12 CONTROLLER l5 REQ�D. OR IF TANDEM TANKS ARE REQ'0. CONSULT FtORN LAKE C.O.E. DEPT. II. TO FIGURE THE HEAT LOAD IN THE MACHINE ROOM SEE SHEET I-N-S. 'J-d R�T DO NOT SCALE i i �• �yQp� ,q�T- THIS DRAWING �� ��x � �T OILDRAULIC EP POWER UNIT f I RLT LA UT R��•T R-L.R. �b+t-!J ����T MAN UAL 1 N 1.2 F ... � i • • . 1i ! •• Job Name Tyrolean Branch/Distributor k ROCM,Y MOUNTAIN / 179 5ales Representa6ve William Daugs _ Up 5peed � 125. i- � i Capacity � i500 _ : ' Mainline Voltage 208 YAC (3 @hase� Existing Plunger diameter � 4,:SS0� Applicable Code � ANs12007 Number of Elevators in Group Stops Front Openings Estimated Travei Car Weight Existing HP Existing JackType L�;_� 4 `31 :^_� 1680 t5.Q Conventional Price Per Elevator (with optionsl � Total Net Pnce per Group � GPM required fot Up Speed 97 Optional Power Unit Modei EP 95 Calculated Horsepower Low Pressure Check Actual Up Speed 122 FPM High Pressure Check If selected, the new Power Unit(s) will be designed per Caltulated HP: 20 Power Feeders may be affected __ TAC 32 ConUOI sys[em (includes Standard Features plus the following:) Solid State Slarter Auto Fan and Light Battery Lowering Yscosity Control (ncluded when selected on Options Page) On Board Diagnostic Taol VISTA Remote Monitoring Tenant Security 3-1 Owners Manuals and Joh Specific Prints Tape Selector system w/ Steel Tape 8 MounGng Hardware (or leveling and limits (final limR not induded) �ring Package TravHing Ca61e and Hoistway wiring including SF2 table tor interlocks (Hoist4vay Ouct klt can be added on the Op6ons Tab, it is not induded in the base) Main Car Sta6on with Required Features ADA compliant Applied panel, Y4 Stainless Steel (Column type Swing available on Options page) Standard Features CE Electronic position indiwtor (Red) ADA phone Emergency Light sysiem with test button CarTreveGng Lantern (1 in�luded) Hall Stations (Fusion Surtace Mounted with Appendix 0) HoisMray Access Key Switrhes (Flush mounted stations or mounted in hafl staUon) Car Top Exit Switch Door Equipment upgrade induding Mechanical Restridor kit (Select one below) O HD-Q4 Door Operator with Drive Arm Adapter and Mounting Plate O HD-04 Door Operator wim GAL Adapter Wheel (if reusing exis6ng GAL Equipmenq (TYiis option is only available �or Left Hand Side Opening and Center Opening applications) O SmartTech II Motor & Board kit (in lieu of HD-04) Janus Model 640 Edge detector Reuse Existing power unit Up Speed: 122 Capacity: 1500 Voltage: 208 VAC (3 Phase) Jadc S¢e: 4.360 Applicable Code: ANSI 2007 HYpower Options Page Number of Eleva[ors: 1 Stops: 4 Front Openings: 4 Travel: 31 Ewsting HP: 15 Car Weight: 1,680 New Power Unit EP 95 H P to be Provided 20 Pipeline Trevel 2Q Gallor�s of Oil Required 105 Net Options Price per Elevator:j � 1 p 21' Tce Guard 1 � 4" Car Roller Guides forT-Rails (indudes guide shoe mamt�g plates and balance weigM Frame) 1 O CarTop Railing 12 O Submersible Power,Unit (I-2 Valve, SO Starts per hour) (indudes Oil) �zD 1 <- Enter pipeline distance from power unit outlet to jack iNet �iions <- Oil (standarcn included fir application °'66 `� . i: allon <- Tank Size required for appliration 12 D 2" Shutoff Valve Kit QTY: 1. 12 ❑ 3" ShutoffValve Kit QN: ' 0`- 12 ❑ Isolaiion Couplings �n' � 12 O Over Speed Valve Kit 2' (less tfian 150GPM) 12 ❑ Over Speed Valve Kit 3' (over 150 GPM) 12 O Seismic Requirements for EP Units 12 O Biodegradable Oil Add 12 O �scosity Control 19 18 22 22 22 D Optlonal Stainless Steel Selector Tape ❑ Hoistway Duct Kit O Add for Swing COP (Match existing Dover/TKE only) Please include photos of ebsting p Add for Microban Antimiaohial Protection Kit (f 1 buttons only) ❑ Additional Car Riding Lantern 23 � Hoistway Jamb Braifle (at all floors) 23 O Car ID Plate (Jamb mounted at Main Egress� 23 ❑ Fusion HaA Digital PI's (CE) �7'f: 0 Fnish will he #4 S/S, Red LED's 23 O Fusion Ha� Lantem & Chime QiY. 0 Finish will be U4 S/S 23 O Fusion Hall Combo PIlLantem QTYc d Finish will be #4 S/S, Red LED's ?3 O Pit Stop Switch Q�'� 1 26 O pic Ladder �G � .„ . � �/?" B ---� j I �/2N I ,a R' =Q "— . cv � Q CONTROLLER � 2�-912� PLAN EP POWER UNITS MODEL TANK CAP A GALS EP-70 1 60 2-9 8 I C CONTROLLER �o � 'v � 2 c? — 2 w Z Z � �w'n , . w -_ D! E I F I G 3�-0'�•� 3-2" { 73�4� �2�-7�4� 2� � 3-3� 66�2=9�����r0�'i 3�-IO��I 73/4 I3� 3314�I 2� � 3-3� t�-�« 75 2� 9�"3-8�/2 3-2" 73/4" EP-150 EP-170 106 2'-9�"3-8%2 3-10° 73/4" EP-190 NOTES: I. TANK SIZE IS SELECTED UStNG TOTAL �A� LONS REQ�D. TO DISPLACE PLUNGER PLUS IOqo. 2. MAXIMUM WORKING PRESSURE IS 500 P.S.I. 3. MINIMUM MACHINE ROOM OOOR SIZE 3�-0° W. � 7=0'� H. 4. FOR WEIGHT SEE SHEET I-N-6. 5. FOR PIPING 5EE SHEETS I-N-3 d 4. 6. REDUCED VOLTAGE STARTING WlTH CLOSED TRANSITION REQUIRES TWO CONTROLLER CABINETS. ONE IS MOUNTED ON THE POWER UNIT AND IS PER OU� STANOARD, THE SECAND IS WALL MOUNTED WITH DIMENSIONS OF 2� 6" W. x 4'-0� H. x 10� C. 7. EMERGENCY POV�ER LOWERING BATTERY TYPE REQUIRES TWO CABINETS. ONE IS MOUNTED ON THE POVYER UNIT AND IS PER OUR STANDARO, THE SECOND IS WALL MOUNTED WITH DIMENSIONS OF I'-33/4"W.: Z' 3°H.: I I� D. AND HOUSES BATTERY ETC. CALL FOR A 4-POLE DlSCONNECT SWITCH OR ONE WITH AN AUXILIARY CONTACT ON LAYOUT. 8. JOBS WITH COMPUTAMATIC�OPERATION REQUIRES ONE COMPUTAMATIC' PANEL WA�� NtOUNTED, PER GROUP WITH �►MENSIONS PER STANDARO CONTROLLER PANE� AND IN AODITION TO STANDARD CONTROLLER PANELS. IF JOB HAS BACK WIRING SEE SHEET I-F-3. 2" 2Y � �F� PIPE SIZE—II� 'w � � � i _� ...... : :.:•_�. . . FRONT VIEW CONTRO��ER CLEARANCE 3'-6'� (4'-0" WHEN ELEC. PANELS FACE EACH OTHER f CLEAR REQ'D. 9. WHEN TANK CAPACITY REQU�RED ON A JOB EXCEEDS 86 GALLONS ON EP-60-95 UNITS USc THE 106 GAI.LON TANK AND USE �B,�C; ANO �G� DIMENSIONS FOR TH15 TANK. WHEN TANK CAPACITY REQUIRED EXCEc'OS 106 GAL�ONS ON EP-125-190 UNITS CONSU�T HORN LAKE C.O.E. DEPT. f0. WHEN NEMA 4, 7, OR 12 CONTROLLER l5 REQ�D. OR IF TANDEM TANKS ARE REQ'0. CONSU�T HORN �AKE C.O.E. DEPT. II. TO FIGURE THE HEAT LOAO IN THE MACHINE ROOM SEE SHEET I-N-S. 00 NOT SCALE I i i �• Fl FYQp(� TH15 DRAWING �� i�� � OILORAULIC EP POWER UNIT om...�,m,.,�.. �K."�.". � �-,_� K" MAN UAL i� I N I 1.2 �F w�V. �m1G Yt[ w TK HYpower Job Name Branch/Distributor q Sales Representadve Up Speed Capacity Mainline Voltage Existing Plunger diameter Applicable Code Tyrolean ROCM,Y MOUNTAIN / 179 William Daugs 125 1500' 1 208 YAC t3 Phssel _. s■ eA Number of Elevators in 6roup �� Stops LU�,_•..J Front Openings 4 EstimatedTrevel 31 ;:� Car Weight � Existing HP � Existing JackType = CBrN1ea Price Per Elevator (with apdor�s) � Total Net Price per Group �_ GPM required for Up Speed 97 Optlonal Power Unit Model E Calwlated Horsepower Low Pressure Check Actual Up Speed 171 FPM High Pressure Check If selected, the new Power Unit(s) will be designed per Calculated HP: ZO Power Feeders may 6e affected , -. TAC 32 Convol system (includes Standard Features plus the following:) Solid State Starter Auto Fan and Light Battery Lowerinp Vscosity Control (included when selected on Options Page) On Board Diagnosuc 7o01 VISTA RemoOe Monitoring Tenant Security 3-1 Owners Manuals and Job Specific Prints Tape Selector system w/ Stecl Tape & Mounting Hardware for leveling and limits (final limR no[ induded) �ring Package Traveling Cable and Hoistway wiring including 5F2 ca61e for interlOCks (Hoistway Duct kit pn be added on the Opoons Tab, it is not included in the base) Main Car Sbtion wiYh Required Features ADA compliant Applied panel, Y4 Stainless Steel (Column type Swing available on Opiions page) Standard Features CE Elearonic position indicator (Red) ADA pho�e Emergency Light system with test button CarTraveGng Lantern (1 included) Hall Sbtions (Fusion Surtace MounLed wlth Appendix 0) HoisMray Access Key Switches (Flush mounted stetions or mounted in haii staUon) Car Top Exit Swihh Door Equipment upgrede induding Mechanical Restrictor kit (Select one below) O HD-04 Door Operator with Drive Arm Adapter and Maunting Plate O HD-04 Door Operator with GAL Adapter Wheel (if reusing existlng GAL Equipmenq (This option is only a�ailable for LeR Hand Side Opening and Center Opening applications) O SmartTech II Motor & Board kit (in lieu of HDA4) Janus Model 640 Edqe detector Reuse Existing power unit Up Speed: 1Z2 Capacity: 1500 Voltage: 208 VAC (3 Phase) Jadc S¢e: 4,360 Applicabie Code: ANSI 2007 HYpower Options Page Number of Elevators: 1 Stops: 4 Fro�t Openings: 4 Travel: 31 Existing HP: 15 Car Weight: 1,680 New Power Unit EP 95 HP to be Provided 20 Pipeline Travel 20 Gallons of Oil Required 105 Net Options Price per E)evator:� -.� 1 O 21' ioe 6uard 1 O 4' Car Roller Guides forT-Rails (indudes guide shoe mounting plates and balance weight frame) 1 O CarTop Railing 12 � Submersible Power.Unit (I-2 Vaive, 80 Starts per hour) (indudes OiI) �� T <- Enter pipeline distance from power unit outlet to jack iniet �allons <- Oil (standar� included for application ' ��" �66;�:•�:�Gallon �-TankSizerequlredforapplication 12 D 2" Shutoff Valve Kit olY: 1: 12 ❑ 3' Shutoff Valve Kit Q1Y: -- 0< < lZ ❑ Isolation Couplings �n' � 12 O Over Speed Vaive Kit 2" (less than 150GPM) 12 � Over Speed Valve Kit 3' (over 150 GPM) 12 O Seismic Requirements for EP Units lZ O Biodegradable Oil Add 12 O �scosiry Control 19 18 22 22 22 D Optional Stainless Steel Selector Tape ❑ Hoistway Duct Kit ❑ Add for Swing COP (Metch e�usting Dover/rKE ony) Please include photos of epsting O Add for Microban Antimiaobial Protection Kit (Tl buttons only) ❑ Additional Car Riding Lantern 23 fO Hoistway Jamb Braille (at all tloors) 23 O Caf ID PIBtB (Jamb mounted at Main Egress) z3 � Fusion Ha9 Digital PI's (CE) �TY: 0: Fnish will be #4 S/S, Red LED's 23 O Fusion Nau Lantem & Chime QTY. Q Finish will be 84 S/S 23 O Fusion Hau Combo PI/Lantern OTY: d Finish will be #4 S/S, Red LED's z3 O Pit Stop Swicch aT1'. 7 ?6 � Pit Ladder „ , . 0-29-201 ..,,, _.Y Inspection v��i orting Requested Inspect Date: Tuesday, October 30, 2012 Site Address: �RO E NDC� N OSAIL Page 20 A/P/D Information Activity: 612-0462 Type: COMBO Sub Type: OTHER Status: ISSUED Const Type: Occupancy : Use: R-2 Insp Area: Owner: HERBERT A. TOBIN AMENDED AND RESTATED RE Phone: 970-376-6541 Contractor: CONTRACTORS GENERAL LLC Description: COMMON ELEMENT: MOVING THE ELEVATOR EQUIPMENT ROOM. Requested Inspection(sl item: 90 BLDG-Final Requestor: CONTRACTORS GENERAL LLC Comments: 376-65 Assigned To: J O AGON Action: Time Exp: Item: 190 ELEC-Final Requestor: Comments: 471-061 Assigned To: J ON Action: Time Exp: Item: 390 MECH-Final Requestor: CONTRACTORS GENERAL LLC Comments: 376-654 Assi ned To� J O GON Requested Time: 10:00 AM Phone: 970-376-6541 Entered By: JMONDRAGON K Requested Time: 08:00 AM Phone: Entered By: MHAEBERLE K Requested Time: 09:30 AM Phone: 970-376-6541 Entered By: JMONDRAGON K 9 Action: Time Exp: r U��`� � �- � � 4 ��” �� � c � Inspection Historv Item: 30 BLDG-Framing 10/16/12 Inspector: Comment: Item: 60 BLDG-Sheetrock Nail 10/18/12 Inspector: Comment: Item: 70 BLDG-Misc. Item: 120 ELEC-Rough 10/16/12 Inspector: Comment: Item: 200 MECH-Rough Item: 190 ELEC-Final Item: 390 MECH-Final Item: 90 BLDG-Final *` Approved *" sgremmer "" Approved *` sgremmer ** Approved'* sgremmer Action: AP APPROVED Action: AP APPROVED Action: AP APPROVED REPT131 Run Id: 14618 *******************+**********************************+************************************* TOWN OF VAIL, COLORADOCopy Reprinted on 01-02-2013 at 08:56:02 O1/02/2013 Statement �********************************************«�********************************************* Statement Number: R120001482 Amount: $3,243.53 09/27/201210:17 AM Payment Method: Check Init: JRM Notation: ----------------------------------------------------------------------------- Permit No: B12-0462 Type: COMBINATION BLDG PERMIT Parcel No: 2101-082-5201-0 Site Address: 400 E MEADOW DR VAIL Location: TYROLEAN CONDOS Total Fees: $3,707.44 This Payment: $3,243.53 Total ALL Pmts: $3,707.44 Balance: $0.00 +*********+*********************+**********************+**********+***********+************* ACCOUNT ITEM LIST: Account Code BP 00100003111100 EP 00100003111100 MP 00100003111100 PF 00100003112300 UT 11000003106000 WC 00100003112800 Description BUILDING PERMIT FEES ELECTRICAL PERMIT FEES MECHANICAL PERMIT FEES PLAN CHECK FEES USE TAX 40 WILL CALL INSPECTION FEE Current Pmts 713.75 115.00 1,060.00 339.78 1,000.00 15.00 -----------------------------------------------------------------------------