Loading...
HomeMy WebLinkAboutF12-0057 PLANS5 12 5151 Bannock St. Denver, CO 80216 303-291-1012 303-383-5023 FAX firesprinkler@afssco.com A FIRE SPRINKLER DESIGN COMPANY MI S - R E P R E S E N T T H E E X A C T L A Y O U T O F T H E LA Y O U T & C A L C U L A T I O N S . AI D T H E A U T H O R I T Y H A V I N G J U R I S D I C T I O N W I T H SP R I N K L E R S C H E M A T I C M A Y I N S O M E C A S E S SP R I N K L E R S Y S T E M . I T I S I N T E N D E D T O H E L P ACCEPTING THIS COPY IS DEEMED AS AGREEING TO THE FOLLOWING: THIS DRAWING COPY, ITS CONTENTS,INFORMATION AND PRINCIPALS OF DESIGN ARE THE EXCLUSIVE PROPERTY OF THE FIRE PROTECTIONCONTRACTOR LISTED AND MILE HIGH DESIGN GROUP, LLC AND IS BEING SUBMITTED TO YOU WITH THEUNDERSTANDING THAT IT IS NOT TO BE REPRODUCED, COPIED OR MODIFIED IN ANY MANNER; NEITHER SHALLIT BE RELAYED IN WHOLE OR IN PART TO ANY OTHER INDIVIDUAL OR FIRM FOR ANY OTHER PROJECT OREXTENSION OF THIS PROJECT EXCEPT THRU WRITTEN AGREEMENT WITH THE FIRE PROTECTION CONTRACTORAND MILE HIGH DESIGN GROUP, LLC. ERRORS AS A RESULT OF THIS FILE BEING ELECTRONICALLYTRANSMITTED ARE BEYOND THE CONTROL OF AND ARE NOT THE RESPONSIBILITY OF THE FIRE PROTECTIONCONTRACTOR OR MILE HIGH DESIGN GROUP. MILE HIGH DESIGN GROUP IS NOT RESPONSIBLE FORINSTALLATION OR INSPECTION OF WORK INSTALLED. THESE PLANS ARE DIAGRAMMATICAL ONLY. ON SITECOORDINATION MUST BE ARRANGED WITH ALL OBSTRUCTIONS, i.e.: MECHANICAL, ELECTRICAL, ANDSTRUCTURAL. ANY ALTERATIONS FROM ENGINEERED DRAWINGS MUST BE APPROVED BY MILE HIGH DESIGNGROUP. MILE HIGH DESIGN GROUP IS NOT RESPONSIBLE FOR LAYOUT DESIGN ISSUES OR CONFLICTS WITHANY OBSTRUCTIONS. IF ADDITIONAL FIRE SPRINKLER PIPING AND/OR FIRE SPRINKLER HEADS ARE REQUIREDTHIS WILL BE THE RESPONSIBILITY OF THE FIRE SPRINKLER CONTRACTOR. ALL CHANGES MUST ME APPROVEDBY MILE HIGH DESIGN GROUP, LLCTHE OWNER IS RESPONSIBLE TO PROVIDE SUFFICIENT HEAT THROUGHOUT THIS BUILDING TO PREVENTFREEZING OF WATER IN THE FIRE SPRINKLER SYSTEM - TH I S S E T O F F I R E S P R I N K L E R S H O P DR A W I N G S H A V E B E E N R E V I E W E D AN D F O U N D T O B E A C C E P T A B L E B Y TI M O T H Y N . T R O S T E L , J R - N . I . C . E . T . IV # 1 0 2 0 5 5 . S R . E N G I N E E R I N G TE C H N I C I A N - F I R E P R O T E C T I O N NA T I O N A L I N S T I T U T E F O R C E R T I F I C A T I O N I N EN G I N N E R I N G T E C H N O L O G I E S __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ / _ _ _ _ / _ _ _ _ Flush212" SingleFDC Horn &StrobeCheckValve 2" c p v c p i p e si d e w a l l h e a d 4" - 6 " u n d e r g a r a g e d o o r pe n d e n t h e a d in c e i l i n g 1" v a l v e t o t e s t an t i f r e e z e 2" c o p p e r 6 h e a d s T/ S T/ S TH I S A N T I F R E E Z E S Y S T E M W I L L H O L D A P R O X 3 0 g a l O F A N T I F R E E Z E S O L U T I O N PR E S S U R I Z E S Y S T E M T O 1 0 2 P S I O F A N T I F R E E Z E S O L U T I O N AN T I - F R E E Z E I S T O B E A P R E - M I X G L Y C E R I N S O L U T I O N . F R E E Z E P O I N T T O B E - 2 0 SO L U T I O N W I L L B E 4 8 % G L Y C E R I N A N D 5 2 % W A T E R PR O V I D E S I G N S T A T I N G A N T I F R E E Z E T Y P E , C O N C E N T R A T I O N AN D F R E E Z E P O I N T CO N T A C T I N F O F O R A N T I F R E E Z E S U P P L I E R G2 S O L U T I O N S 90 0 9 Q U I N C E S T R E E T , U N I T C HE N D E R S O N , C O 30 3 - 2 8 7 - 4 8 7 0 STEE L P I P E 39 t o t a l s p r i n k l e r s f o r t h i s j o b 102.000.0097.001300.00 an y e x p o s e d p i p e s ar e t o b e c o p p e r NO T E : NO S P R I N K L E R S C L O S E R TH A N 3 ' - 0 " T O T H E C E N T E R O F CE I L I N G F A N S NOTE:ANY SPR I N K L E R S W I T H I N 5 FEET OF M E C H A N I C A L EQUIPME N T S H A L L B E A N INTERME D I A T E TEMPERA T U R E S P R I N K L E R <5 5 s q f t 5151 Bannock St. Denver, CO 80216 303-291-1012 303-383-5023 FAX firesprinkler@afssco.com A FIRE SPRINKLER DESIGN COMPANY ACCEPTING THIS COPY IS DEEMED AS AGREEING TO THE FOLLOWING: THIS DRAWING COPY, ITS CONTENTS,INFORMATION AND PRINCIPALS OF DESIGN ARE THE EXCLUSIVE PROPERTY OF THE FIRE PROTECTIONCONTRACTOR LISTED AND MILE HIGH DESIGN GROUP, LLC AND IS BEING SUBMITTED TO YOU WITH THEUNDERSTANDING THAT IT IS NOT TO BE REPRODUCED, COPIED OR MODIFIED IN ANY MANNER; NEITHER SHALLIT BE RELAYED IN WHOLE OR IN PART TO ANY OTHER INDIVIDUAL OR FIRM FOR ANY OTHER PROJECT OREXTENSION OF THIS PROJECT EXCEPT THRU WRITTEN AGREEMENT WITH THE FIRE PROTECTION CONTRACTORAND MILE HIGH DESIGN GROUP, LLC. ERRORS AS A RESULT OF THIS FILE BEING ELECTRONICALLYTRANSMITTED ARE BEYOND THE CONTROL OF AND ARE NOT THE RESPONSIBILITY OF THE FIRE PROTECTIONCONTRACTOR OR MILE HIGH DESIGN GROUP. MILE HIGH DESIGN GROUP IS NOT RESPONSIBLE FORINSTALLATION OR INSPECTION OF WORK INSTALLED. THESE PLANS ARE DIAGRAMMATICAL ONLY. ON SITECOORDINATION MUST BE ARRANGED WITH ALL OBSTRUCTIONS, i.e.: MECHANICAL, ELECTRICAL, ANDSTRUCTURAL. ANY ALTERATIONS FROM ENGINEERED DRAWINGS MUST BE APPROVED BY MILE HIGH DESIGNGROUP. MILE HIGH DESIGN GROUP IS NOT RESPONSIBLE FOR LAYOUT DESIGN ISSUES OR CONFLICTS WITHANY OBSTRUCTIONS. IF ADDITIONAL FIRE SPRINKLER PIPING AND/OR FIRE SPRINKLER HEADS ARE REQUIREDTHIS WILL BE THE RESPONSIBILITY OF THE FIRE SPRINKLER CONTRACTOR. ALL CHANGES MUST ME APPROVEDBY MILE HIGH DESIGN GROUP, LLCTHE OWNER IS RESPONSIBLE TO PROVIDE SUFFICIENT HEAT THROUGHOUT THIS BUILDING TO PREVENTFREEZING OF WATER IN THE FIRE SPRINKLER SYSTEM - TH I S S E T O F F I R E S P R I N K L E R S H O P DR A W I N G S H A V E B E E N R E V I E W E D AN D F O U N D T O B E A C C E P T A B L E B Y TI M O T H Y N . T R O S T E L , J R - N . I . C . E . T . IV # 1 0 2 0 5 5 . S R . E N G I N E E R I N G TE C H N I C I A N - F I R E P R O T E C T I O N NA T I O N A L I N S T I T U T E F O R C E R T I F I C A T I O N I N EN G I N N E R I N G T E C H N O L O G I E S __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ / _ _ _ _ / _ _ _ _ 39 total sprinklers for this job10 heads for this page SC A L E : 1 / 4 " = 1 ' - 0 " PL A N NO R T H FI R E S P R I N K L E R P L A N S LO W E R L E V E L S 1 2 3 4 5 6 7 8 9 10 any exposed pipesare to be copperNOTE:NO SPRINK L E R S C L O S E R THAN 3'-0" T O T H E C E N T E R O F CEILING FA N S <55sqft DA N a m e : 2 DA A r e a : 3 7 6 . 2 2 <5 5 s q f t Th i s s y s t e m a s s h o w n o n co m p a n y p r i n t n o da t e d fo r at co n t r a c t n o is d e s i g n e d t o d i s c h a r g e a t a r a t e o f a m a x i m u m a r e a o f wh e n s u p p l i e d w i t h w a t e r a t a r a t e o f Oc c u p a n c y c l a s s i f i c a t i o n : Co m m o d i t y c l a s s i f i c a t i o n : Ma x i m u m s t o r a g e h e i g h t : St o r a g e a r r a n g e m e n t : Nu m b e r o f h e a d s f l o w i n g : Sy s t e m T y p e : Ma x i m u m v e l o c i t y : Fl o w f r o m I n - R a c k s p r i n k l e r s : Fl o w f r o m O v e r h e a d s p r i n k l e r s : Fl o w f r o m I n s i d e H o s e s : Fl o w f r o m O u t s i d e H o s e s : Ot h e r f i x e d f l o w s : To t a l f l o w i n s y s t e m p i p i n g : Ad d i t i o n a l f l o w a t / b e y o n d s o u r c e : To t a l o f a l l f l o w s : Ca l c u l a t i o n r e s u l t s f o r D e s i g n A r e a JS P  I W ð  /  P L Q  P ð  R I  I O R R U  D U H D  R Y H U - Su r p l u s P r e s s u r e a t S o u r c e : Pr e s s u r e R e q u i r e d a t S o u r c e : Pr e s s u r e A v a i l a b l e a t S o u r c e : at at t h e b a s e o f t h e r i s e r . Ho s e s t r e a m a l l o w a n c e o f is i n c l u d e d i n t h e a b o v e . 2 Pl a y R o o m Ph o e n i x A u t o m a t i c 7/ 1 8 / 1 2 Di a z a y a R e s 18 9 5 W . G o r e C r e e k D r . 0. 1     I W ð 10 9 . 1 g p m 78 . 9 p s i Dw e l l i n g 4We t 17 . 4 5 f t / s 0 g p m 10 9 . 1 g p m 0 g p m 0 g p m 0 g p m 10 9 . 1 g p m 0 g p m 10 9 . 1 g p m 78 . 9 p s i 10 1 . 9 p s i 23 . 1 p s i 5151 Bannock St. Denver, CO 80216 303-291-1012 303-383-5023 FAX firesprinkler@afssco.com A FIRE SPRINKLER DESIGN COMPANY ACCEPTING THIS COPY IS DEEMED AS AGREEING TO THE FOLLOWING: THIS DRAWING COPY, ITS CONTENTS,INFORMATION AND PRINCIPALS OF DESIGN ARE THE EXCLUSIVE PROPERTY OF THE FIRE PROTECTIONCONTRACTOR LISTED AND MILE HIGH DESIGN GROUP, LLC AND IS BEING SUBMITTED TO YOU WITH THEUNDERSTANDING THAT IT IS NOT TO BE REPRODUCED, COPIED OR MODIFIED IN ANY MANNER; NEITHER SHALLIT BE RELAYED IN WHOLE OR IN PART TO ANY OTHER INDIVIDUAL OR FIRM FOR ANY OTHER PROJECT OREXTENSION OF THIS PROJECT EXCEPT THRU WRITTEN AGREEMENT WITH THE FIRE PROTECTION CONTRACTORAND MILE HIGH DESIGN GROUP, LLC. ERRORS AS A RESULT OF THIS FILE BEING ELECTRONICALLYTRANSMITTED ARE BEYOND THE CONTROL OF AND ARE NOT THE RESPONSIBILITY OF THE FIRE PROTECTIONCONTRACTOR OR MILE HIGH DESIGN GROUP. MILE HIGH DESIGN GROUP IS NOT RESPONSIBLE FORINSTALLATION OR INSPECTION OF WORK INSTALLED. THESE PLANS ARE DIAGRAMMATICAL ONLY. ON SITECOORDINATION MUST BE ARRANGED WITH ALL OBSTRUCTIONS, i.e.: MECHANICAL, ELECTRICAL, ANDSTRUCTURAL. ANY ALTERATIONS FROM ENGINEERED DRAWINGS MUST BE APPROVED BY MILE HIGH DESIGNGROUP. MILE HIGH DESIGN GROUP IS NOT RESPONSIBLE FOR LAYOUT DESIGN ISSUES OR CONFLICTS WITHANY OBSTRUCTIONS. IF ADDITIONAL FIRE SPRINKLER PIPING AND/OR FIRE SPRINKLER HEADS ARE REQUIREDTHIS WILL BE THE RESPONSIBILITY OF THE FIRE SPRINKLER CONTRACTOR. ALL CHANGES MUST ME APPROVEDBY MILE HIGH DESIGN GROUP, LLCTHE OWNER IS RESPONSIBLE TO PROVIDE SUFFICIENT HEAT THROUGHOUT THIS BUILDING TO PREVENTFREEZING OF WATER IN THE FIRE SPRINKLER SYSTEM - TH I S S E T O F F I R E S P R I N K L E R S H O P DR A W I N G S H A V E B E E N R E V I E W E D AN D F O U N D T O B E A C C E P T A B L E B Y TI M O T H Y N . T R O S T E L , J R - N . I . C . E . T . IV # 1 0 2 0 5 5 . S R . E N G I N E E R I N G TE C H N I C I A N - F I R E P R O T E C T I O N NA T I O N A L I N S T I T U T E F O R C E R T I F I C A T I O N I N EN G I N N E R I N G T E C H N O L O G I E S __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ / _ _ _ _ / _ _ _ _ 39 total sprinklers for this job25 heads for this pageSCALE: 1/4" = 1'-0"PLANNORTH FIRE SPRINKLER PLANS MA I N / M A S T E R L E V E L 1 2 3 4 5 6 7 8 9 10 SC A L E : 1 / 4 " = 1 ' - 0 " PL A N NO R T H FI R E S P R I N K L E R P L A N S UP P E R L E V E L 1 1 2 3 4 5 6 7 8 9 10 DA N a m e : 1 DA A r e a : 3 5 8 . 1 5 ca l c u l a t e d f o r s l o p e d ce i l i n g s o v e r 4 : 1 2 p i t c h <55sqft NO T E : NO S P R I N K L E R S C L O S E R TH A N 3 ' - 0 " T O T H E C E N T E R O F CE I L I N G F A N S Th i s s y s t e m a s s h o w n o n co m p a n y p r i n t n o da t e d fo r at co n t r a c t n o is d e s i g n e d t o d i s c h a r g e a t a r a t e o f a m a x i m u m a r e a o f wh e n s u p p l i e d w i t h w a t e r a t a r a t e o f Oc c u p a n c y c l a s s i f i c a t i o n : Co m m o d i t y c l a s s i f i c a t i o n : Ma x i m u m s t o r a g e h e i g h t : St o r a g e a r r a n g e m e n t : Nu m b e r o f h e a d s f l o w i n g : Sy s t e m T y p e : Ma x i m u m v e l o c i t y : Fl o w f r o m I n - R a c k s p r i n k l e r s : Fl o w f r o m O v e r h e a d s p r i n k l e r s : Fl o w f r o m I n s i d e H o s e s : Fl o w f r o m O u t s i d e H o s e s : Ot h e r f i x e d f l o w s : To t a l f l o w i n s y s t e m p i p i n g : Ad d i t i o n a l f l o w a t / b e y o n d s o u r c e : To t a l o f a l l f l o w s : Ca l c u l a t i o n r e s u l t s f o r D e s i g n A r e a JS P  I W ð  /  P L Q  P ð  R I  I O R R U  D U H D  R Y H U - Su r p l u s P r e s s u r e a t S o u r c e : Pr e s s u r e R e q u i r e d a t S o u r c e : Pr e s s u r e A v a i l a b l e a t S o u r c e : at at t h e b a s e o f t h e r i s e r . Ho s e s t r e a m a l l o w a n c e o f is i n c l u d e d i n t h e a b o v e . 1 Up p e r L e v e l Ph o e n i x A u t o m a t i c 7/ 1 8 / 1 2 Di a z a y a R e s 18 9 5 W . G o r e C r e e k D r . 0. 1     I W ð 11 0 g p m 78 . 4 p s i Dw e l l i n g 4We t 17 . 6 f t / s 0 g p m 11 0 g p m 0 g p m 0 g p m 0 g p m 11 0 g p m 0 g p m 11 0 g p m 78 . 4 p s i 10 1 . 9 p s i 23 . 5 p s i 5151 Bannock St. Denver, CO 80216 303-291-1012 303-383-5023 FAX firesprinkler@afssco.com A FIRE SPRINKLER DESIGN COMPANY ACCEPTING THIS COPY IS DEEMED AS AGREEING TO THE FOLLOWING: THIS DRAWING COPY, ITS CONTENTS,INFORMATION AND PRINCIPALS OF DESIGN ARE THE EXCLUSIVE PROPERTY OF THE FIRE PROTECTIONCONTRACTOR LISTED AND MILE HIGH DESIGN GROUP, LLC AND IS BEING SUBMITTED TO YOU WITH THEUNDERSTANDING THAT IT IS NOT TO BE REPRODUCED, COPIED OR MODIFIED IN ANY MANNER; NEITHER SHALLIT BE RELAYED IN WHOLE OR IN PART TO ANY OTHER INDIVIDUAL OR FIRM FOR ANY OTHER PROJECT OREXTENSION OF THIS PROJECT EXCEPT THRU WRITTEN AGREEMENT WITH THE FIRE PROTECTION CONTRACTORAND MILE HIGH DESIGN GROUP, LLC. ERRORS AS A RESULT OF THIS FILE BEING ELECTRONICALLYTRANSMITTED ARE BEYOND THE CONTROL OF AND ARE NOT THE RESPONSIBILITY OF THE FIRE PROTECTIONCONTRACTOR OR MILE HIGH DESIGN GROUP. MILE HIGH DESIGN GROUP IS NOT RESPONSIBLE FORINSTALLATION OR INSPECTION OF WORK INSTALLED. THESE PLANS ARE DIAGRAMMATICAL ONLY. ON SITECOORDINATION MUST BE ARRANGED WITH ALL OBSTRUCTIONS, i.e.: MECHANICAL, ELECTRICAL, ANDSTRUCTURAL. ANY ALTERATIONS FROM ENGINEERED DRAWINGS MUST BE APPROVED BY MILE HIGH DESIGNGROUP. MILE HIGH DESIGN GROUP IS NOT RESPONSIBLE FOR LAYOUT DESIGN ISSUES OR CONFLICTS WITHANY OBSTRUCTIONS. IF ADDITIONAL FIRE SPRINKLER PIPING AND/OR FIRE SPRINKLER HEADS ARE REQUIREDTHIS WILL BE THE RESPONSIBILITY OF THE FIRE SPRINKLER CONTRACTOR. ALL CHANGES MUST ME APPROVEDBY MILE HIGH DESIGN GROUP, LLCTHE OWNER IS RESPONSIBLE TO PROVIDE SUFFICIENT HEAT THROUGHOUT THIS BUILDING TO PREVENTFREEZING OF WATER IN THE FIRE SPRINKLER SYSTEM - TH I S S E T O F F I R E S P R I N K L E R S H O P DR A W I N G S H A V E B E E N R E V I E W E D AN D F O U N D T O B E A C C E P T A B L E B Y TI M O T H Y N . T R O S T E L , J R - N . I . C . E . T . IV # 1 0 2 0 5 5 . S R . E N G I N E E R I N G TE C H N I C I A N - F I R E P R O T E C T I O N NA T I O N A L I N S T I T U T E F O R C E R T I F I C A T I O N I N EN G I N N E R I N G T E C H N O L O G I E S __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ / _ _ _ _ / _ _ _ _ 39 total sprinklers for this job 4 heads for this page SC A L E : 1 / 4 " = 1 ' - 0 " PL A N NO R T H FI R E S P R I N K L E R P L A N S UP P E R L E V E L S 2 & 3 1 2 3 4 5 6 7 8 9 10