Loading...
HomeMy WebLinkAboutB12-0467rowN of va` ilk Department of Community Development 75 South Frontage Road Vail, CO 81657 Tel: 970 - 479 -2128 www.vailgov.com Development Review Coordinator BUILDING PERMIT APPLICATION (Separate applications are required for alarm & sprinkler) Project Street Address: 715 West Lionshead Circle (Number) (Street) Building /Complex Name: Marriott Resort & Spa Contractor Information Business Name: JL Viele Construction (Suite #) Business Address: 2111 N Frontage Road West Suite E City Vail Contact Name: Scott Ashburn Contact Phone: 970.476.3082 Project #: pg_� — o S DRB #: — IJA - Building Permit #:� Lot #: Block # Subdivision: Work Class: New 0 Addition 0 Alteration ((i) State: CO Zip: 81657 Type of Building: Single - Family 0 Duplex 0 Multi - Family (� Commercial (V) Other 0 Contact E -Mail: scott@vieleconstruction.com I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the town's zoning and subdivision codes, design review ap- proved, International Building and Residential Codes and other ordinance 'Tthe T6w p licable thereto. X Owner /Owner's Representative Signature (Required) Applicant Information Applicant Name: Scott Ashburn Applicant Phone: 970.476.3082 Applicant E -Mail: Scott @vieleconstruction.com Project Information Owner Name: Vail Marriott Resort & Spa Parcel #: Z 10 ( — O'�- 2— I_�— 0 O ( (For Parcel #, contact Eagle County Assessors Office at (970- 328 -8640 or visit www.eaglecounty.uslpatie) For Office Use On IN: Fee Paid: Received From: Cash Check #, CC: Visa / MC Last 4 CC # Auth # exp date: Work Type: Interior Q Exterior 0 Both 0 Value of all work being performed: $ 110000 (value based on IBC Section 109.3 & IRC Section 108.3) Electrical Square Footage 2288 Detailed Scope and Location of Work: Relocation of existing fitness center in place of existing meeting room. Reloaction of exisiting meeting room in place of fitness center. (use additional sheet if necessary) Date Received ( V r SEP 7 2012 `T y° TO N OF VAIL z Valuation of Work Included Plans Included Work Electrical GYes O)No (F)Yes ONO 20000 Mechanical (i)Yes O)No (�)Yes ONo 15000 Plumbing Yes ONo Yes ONo 2000 Building (i)Yes O)No Yes ONo 73000 Value of all work being performed: $ 110000 (value based on IBC Section 109.3 & IRC Section 108.3) Electrical Square Footage 2288 Detailed Scope and Location of Work: Relocation of existing fitness center in place of existing meeting room. Reloaction of exisiting meeting room in place of fitness center. (use additional sheet if necessary) Date Received ( V r SEP 7 2012 `T y° TO N OF VAIL z COMcheck Software Version 3.9.1 Interior Lighting and Power Compliance Certificate 90.1 (2007) Standard Section 1: Project Information Project Type: New Construction Project Title : Vail Marriott Remodel - Add Alternate Construction Site: 715 W. Lionshead Circle Vail, CO 81657 %4 O1VA Owner /Agent: Designer /Contractor: Jeff Mullikin Architectural Engineering Design Group 1900 Wazee Street, Suite #350 Denver, CO 80202 303.296.3034 Section 2: Interior Lighting and Power Calculation A B C D Area Category Floor Area Allowed Allowed Watts (ft2) Watts / ft2 (B x C) Board Room (Common Space Types: Conference /Meeting /Multipurpose) 1534 1.3 1994 Total Allowed Watts = 1994 Section 3: Interior Lighting Fixture Schedule A B C D E Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast Lamps/ # of Fixture (C X D) Fixture Fixtures Watt. Board Room ( Common Space Types: Conference /Meeting /Multipurpose 1534 sq.ft.) Compact Fluorescent 1: D1: Fluorescent Downlight / Triple 4 -pin 32W / Dimming 1 36 35 1260 Total Proposed Watts = 1260 Section 4: Requirements Checklist code. Interior Lighting PASSES� Design 37% better than Lighting Wattage: ETOIiN jd 1. Total proposed watts must be less than or equal to total allowed watts. Allowed Watts Proposed Watts Complies 2012 1994 1260 YES 2. Exit signs 5 Watts or less per sign. Controls, Switching, and Wiring: OF VAIL Lj 3. Independent manual or occupancy sensing controls for each space (remote switch with indicator allowed for safety or security). 0 4. Occupant sensing control in class rooms, conference /meeting rooms, and employee lunch and break rooms. Exceptions: ❑ Spaces with multi -scene control; shop classrooms, laboratory classrooms, and preschool through 12th grade classrooms. F1 5. Automatic shutoff control for lighting in >5000 sq.ft buildings by time -of -day device, occupant sensor, or other automatic control. Exceptions: ❑ 24 hour operation lighting; patient care areas; where auto shutoff would endanger safety or security. ❑ 6. Master switch at entry to hotel /motel guest room. Project Title: Vail Marriott Remodel - Add Alternate Data filename: J: \2314.00 - Vail Marriot \Ltg Calcs \231400LC01 -Space x Space ASHRAE90_1.cck Report date: 09/13/12 Page 1 of 2 0 7. Separate control device for display /accent lighting, case lighting, task lighting, nonvisual lighting, lighting for sale, and demonstration lighting. 8. Tandem wired one -lamp and three -lamp ballasted luminaires (No single -lamp ballasts). Exceptions: Electronic high- frequency ballasts. 0 RFG F-I Luminaires not on same switch. •4f, � Recessed luminaires 10 ft. apart or surface /pendant not continuous. v,• Luminaires on emergency circuits. % Voltage Drop: Fw 9. Feeder conductors have been designed for a maximum voltage drop of 2 percent. •• ......... ( � 0 10.Branch circuit conductors have been designed for a maximum voltage drop of 3 percent. rC►NAL Section 5: Compliance Statement Compliance Statement: The proposed lighting design represented in this document is consistent with the building plans, specifications and other calculations submitted with this permit application. The proposed lighting system has been designed to meet the 90.1 (2007) Standard requirements in COMcheck Version 3.9.1 and to comply with the 4to uirements in the Requirements Checklist. Jeff Mullikin, Principal 9/13/2012 Name - Title Date Section 5: Post Construction Compliance Statement Record Drawings and Operating and Maintenance Manuals: ❑ 1. Construction documents with record drawings and operating and maintenance manuals provided to the owner. Lighting Designer or Contractor Name Signature Date Project Notes: COMCheck is being performed for Add Alternate set of lighting for new board room. Base bid is existing to remain. Project Title: Vail Marriott Remodel - Add Alternate Report date: 09/13/12 Data filename: J: \2314.00 - Vail Marriot\Ltg Calcs \231400LC01 -Space x Space ASHRAE90_1.cck Page 2 of 2 12-05-2012 Inspection Request Reporting Page 10 4:10 pm Vail, CO - City Of pnt2 '050 Requested Inspect Date: Thursday December 06, 2012 Site Address: 720 W LIy NSHEAD CR VAIL MARRIOTT RESORT&SPA A/P/D Information Activity B12-0467 Type: COMBO Sub Type: ACOM Status: ISSUED Const Type Occupancy: Use: Insp Area: Owner DIAMONDROCK VAIL OWNER LLC Contractor: J.L.VIELE CONSTRUCTION INC. Phone: 970-476-3082 Description: RELOCATION OF EXISTING FITNESS CENTER AND EXISTING MEETING ROOM. SWAPPING LOCATIONS OF EACH. Requested Inspection(s) Item 190 ELEC-Final Requested Time: 09:00 AM Requestor J.L.VIELE CONSTRUCTION INC. Phone: 970-476-3082 Comments 471- 124: _ Assigned To Entered By: JMONDRAGON K Action 'I'N2.Avr Time Exp: Comment ` o r..m Item 290 PLMB-Final Requested Time: 09:30 AM Requestor J.L.VIELE CONSTRUCTION INC. Phone: 970-476-3082 Comments 471-1121 Assigned To ; ER Entered By: JMONDRAGON K Action or -..o 'room Time Exp: Comment Item 390 MECH-Final Requested Time: 10:00 AM Requestor J.L.VIE ONSTRUCTION INC. Phone: 970-476-3082 Comments 471-11 'r Assigned To ; MI ;4; Entered By: JMONDRAGON K Action •la_ Time Exp: Comment :r ou room l Inspection History Item: 120 ELEC-Rough **Approved** 10/31/12 Inspector: sgremmer Action: AP APPROVED Comment: Item 140 ELEC-Misc. Item 200 MECH-Rough Item 210 PLMB-Underground Item 220 PLMB-Rough7D.W.V. **Approved** 10/31/12 Inspector: sgremmer Action: AP APPROVED Comment: NA Item: 230 PLMB-Rough/Water **Approved** 10/31/12 Inspector: sgremmer Action: AP APPROVED Comment: tern 240 PLMB-Gas Piping tern 310 MECH-Heating tern 340 MECH-Misc. tem 320 MECH-Exhaust Hoods tern 330 MECH-Supply Air tern 90 BLDG-Final REPT131 Run Id: 15031 1