HomeMy WebLinkAboutDRB12045917M IJ, CcMidMNUN17Y DEVELOPMEN7 Design Review Board 'T'I'N FORM Depaurtrrment of Community IDevelopment 7'5 'South Furontage Road, V,aiil, Colorado, 81657 tell: 97'0.479.2139 fax: 970.479.2452 web: www.vaiilgov.cormi Project Name: ]AT RES. DECK SUPPORT REPAIRS DRB Number: DRB120459 Project Description: REHABILITATE EXISTING DECK STRUCTURAL SUPPORT SYSTEM. Participants: OWNER ]AT FAMILY PARTNERSHIP LLLP 09/24/2012 1200 17TH ST STE 1025 DENVER, CO 80202 APPLICANT ]AT FAMILY PARTNERSHIP LLLP 09/24/2012 1200 17TH ST STE 2420 DENVER CO 80202 Project Address: 223 BEAVER DAM RD VAIL Location: Legal Description: Lot: 39 Block: 7 Subdivision: VAIL VILLAGE FILING 1 Parcel Number: 2101 - 071 - 1200 -4 Comments: See conditions BOARD /STAFF ACTION Motion By: Action: STAFFAPP Second By: Vote: Date of Approval: 09/28/2012 Conditions: Cond: 8 (PLAN): No changes to these plans may be made without the written consent of Town of Vail staff and /or the appropriate review committee(s). Cond: 0 (PLAN): DRB approval does not constitute a permit for building. Please consult with Town of Vail Building personnel prior to construction activities. Cond: 201 (PLAN): DRB approval shall not become valid for 20 days following the date of approval, pursuant to the Vail Town Code, Chapter 12 -3 -3: APPEALS. Cond:202 (PLAN): Approval of this project shall lapse and become void one (1) year following the date of final approval, unless a building permit is issued and construction is commenced and is diligently pursued toward completion. Cond: CON0012835 The applicant shall match all the new and repaired deck columns and supports to the existing architectural style, marterials, and colors prior to requesting a final planning inspection. Planner: Warren Campbell DRB Fee Paid: $20.00 TOWN OF VA SEP 21 2012 X,ySpM 3� TOWN OF VAI Department of Community Development 75 South Frontage Road Vail, CO 81657 Tel: 970-479 -2128 www.vailgov.com Development Review Coordinator Application for Design Review Minor Exterior Alteration General Information: This application is required for all proposals involving minor changes to buildings and site improve- ments, such as roofing, painting, window additions, landscaping, fences, retaining walls, etc. Applicable Vail Town Code sections can be found at www.vail-Qov.com under Vail Information — Town Code Online. All projects requiring de- sign review must receive approval prior to submitting a building permit application An application for Design Review cannot be accepted until all required information is received by the Community Development Department, as outlined in the submittal requirements. The project may also need to be reviewed by the Town Council and /or the Planning and Environmental Commission. Design review approval expires one year from the date of approval, unless a building per- mit is issued and construction commences. Fee: $250 for Multi - Family /Commercial $20 for Single Family /Duplex Single Family ( Duplex Multi - Family I Commercial Description of the Request: t X < ��'� �. J ppurt5 Physical Address: Parcel Number: Property Owner: Mailing Address 2Z 3 RICA ✓v L)c-jeyj J�V L (01 U? 11 L Oo y (Contact Eagle Co. Assessor at 970 - 328 -8640 for parcel no.) Cam( wcv,15: Phone: 333 Owner's Signature:.- Primary Contact/ Owner Representative: Mailing Address: /Oeof -f ".,7a '10r .V4 a0.?D _ e2r ed 914%?62, Phone: -T03 Rtom' /00 rJQ E -Mail: �/��•E�IEtotri.r� . Gv..�Fax: For Office Use Only: Cash V/CC: Visa / MC Last 4 CC # Exp. Date: _ Auth It Check # Fee Paid: 4, c),o Received From:._ —.I IT r 4 Cnw6ilrgD5 Meeting Date: DRB No.: Q � l Planner: Project No: Zoning: Location of the Proposal: Lot:_ 39 Block: Land Use: Subdivision:_VP�IL_ 'i/ 1LLIVISVE RESOLUTION D E S I G N 9.21.12 Town of Vail Community Development 75 South Frontage Road Vail, Colorado 81658 Attn: Mr. Bill Gibson, AICP Town Planner Re: The Edwards Residence 223 Beaver Dam Road Exterior Deck Rehabilitation Dear Bill, We are pleased to submit the attached documents describing the work to be completed on the Edwards Residence located at 223 Beaver Dam Road. As we discussed in our meeting on Friday, September 14, the proposed work is intended to rehabilitate and make usable the exterior decks of the home. As such, we are applying to DRB for a "Minor Exterior Alteration ". As you can see from the attached documents, the existing deck support structure has deteriorated to the point that the decks are no longer deemed safe to use. The proposed work is to make the deck support structure functional and safe for the Owner and his family. We are neither increasing, nor decreasing the existing size or configuration of the decks in any way. Therefore, we are requesting that the work as proposed be approved as soon as possible by your department. This will allow the documents to be submitted to Town of Vail Building Department for a construction permit, and the work to be completed prior to the coming winter months. Should you have any questions, please feel free to contact me at any time Regards, Ronald D. Kirkham architect / principal ron@resodes.com PO Box 5631 Vail, Colorado 81658 970.376.1793 ARCHITECTURE. DESIGN. SOLUTIONS. Residence at 223 Beaver Dam Road Exterior Deck Rehabilitation Photo Descriptions Note: Photo numbers correspond to numbers on Basement Level Floor Plan 1) Overall view of West elevation showing existing conditions. 2) Stucco clad CMU entry column showing that column has shifted on CMU footing. 3) Stucco clad CMU entry column showing insufficient CMU footing depth. 4) CMU and timber columns have shifted out of plumb. 5) Timber column on CMU footer has shifted on CMU footing of insufficient depth. Timber is not tied to footing. 6) View of timber columns that have shifted out of plumb. 7) Timber column on CMU base has shifted. Timber is not tied to footing. 8) East deck from below showing sagging deck. 9) Timber column on concrete footing that has shifted. Timber is not tied to footing. 10) Timber column on concrete footing that has shifted /heaved. Timber is not tied to footing and is shimmed with wood shims. 11) Timber column on concrete footing that has shifted /heaved. Timber is not tied to footing. 12) View of tops of timber columns showing how deck has shifted when footings moved. 13) View of deck looking north indicating substantial deck movement. PO Box 5631 ARCHITECTURE. ,MANJ� RESOLUTION D E S I G N Vail, Colorado 81658 DESIGN. 970.376.1793 SOLUTIONS. Residence at 223 Beaver Dam Road Exterior Deck Rehabilitation Photo #1: West elevation: overall view Photo #2: CMU Column Base Residence at 223 Beaver Dam Road Exterior Deck Rehabilitation Photo #3: CMU Column on Footer Photo #4: Columns & Bases Residence at 223 Beaver Dam Road Exterior Deck Rehabilitation Photo #5: Timber Column on CMU footer Photo #6: Timber columns on CMU footers Residence at 223 Beaver Dam Road Exterior Deck Rehabilitation Photo #7: Timber columns on CMU footers Photo #8: East deck from below Residence at 223 Beaver Dam Road Exterior Deck Rehabilitation Photo #9: Timber column on concrete footer #1 Photo #10: Timber column on concrete footer #2 Residence at 223 Beaver Dam Road Exterior Deck Rehabilitation Photo #11: Timber column on concrete footer #3 Photo #12: Timber columns tops Residence at 223 Beaver Dam Road Exterior Deck Rehabilitation Photo #12: Looking North at existing deck rd RESOLUTION D E S I G N PO Box 5631 Vail, Colorado 81658 970.376.1793 ARCHITECTURE. DESIGN. SOLUTIONS. EXISTING 2X12 WD_ BEAMS TO BE REPLACED_ RE= STRUCTURAL EX15TING (ox5 WC BEAM TO BE REPLACED_ RE; STRUCTURAL EXISTING 2X6 DE TO REMAIN TYP_ r 1-05T5 AND r► KAILING TO RE EXISTING 2Xta DE TO REMAIN TYP. 5E OND LEVEL PLAN A1.0 SCALE; 1/4 "=1 °_o.► EXISTING CONC. COLUMN FOOTINGS TO BE REPLACED A5 -- REQUIRED. RE-- STRUCTURAL GENERAL NOTES 1_ CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING TEMPORARY SERVICES SUCH AS POWER, LIGHT, HEAT, ENCLOSURES, WATER, SANITARY FACILITIES, EROSION AND SEDIMENT CONTROL, TEMPORARY CONSTRUCTION FENCING, TREE AND PLANT PROTECTION, AND TRASH REMOVAL ADEQUATE TO MEET REQUIREMENTS OF LOCAL ,JURISDICTIONS, MAINTAIN SAFETY OF THE SITE, AND MAINTAIN QUALITY, FOR THE DURATION OF CONSTRUCTION_ 2_ CONTRACTOR SHALL MAINTAIN QUALITY CONTROL OVER SUPPLIES, MANUFACTURERS, PRODUCTS, SERVICES, SITE CONDITIONS AND WORKMANSHIP TO PRODUCE THE QUALITY LEVEL SPECIFIED IN ALL CASES_ 3, ALL PRODUCTS SHALL BE INSTALLED STRICTLY PER MANUFACTURER'S RECOMMENDATIONS AND /OR STANDARD TRADE COUNCIL GUIDELINES_ 4. COMMENCEMENT OF WORK OVER PREVIOUS WORK INDICATES THAT INSTALLER HAS REVIEWED THE PREVIOUS WORK AND AGREES IT 15 ACCEPTABLE AS A SUBSTRATE FOR HIS WORK g. ALL CONTRACTORS ARE RESPONSIBLE FOR REPAIRING OR REPLACING ANY DISTURBED OR DAMAGED MATERIALS DURING THE SCOPE OF TH15 PROJECT_ 1 8 � EX15TING SX12 WD- COLUMNS TO BE I RE -USED I I EX16TINGx DECK I ABOVE 1 I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I (I f I EXISTING DECK I ABOVE I I EXISTING CONC- COLUMN FOOTINGS TO BE I REPLACED AS I REQUIRED. RE= STRUCTURAL I EXISTING IOXIO WD, COLUMNS ♦ BE .. Mr I� I --------------------- ._.._ - - - --� I I I i I I I I I I I ci M-MMMM TOWN OF VAIL 2009 INTERNATIONAL RESIDENTIAL CODE 2009 INTERNATIONAL PLUMBING CODE 2005 INTERNATIONAL MECHANICAL DRAWING L I6T: A1.0 ARCHITECTURAL FLOOR PLANS $1.0 STRUCTURAL GENERAL NOTES, FOUNDATION PLAN d DTLS_ 52.0 5TRUCTUAL MAIN LEVEL DECK. FRAMING PAND d DTI-5, PHOTO DESCRIPTIONS OF EXISTING CONDITIONS ------- LEI ----- INDICATES PHOTO DESCRIPTION PROVIDED OF EXISTING CONDITIONS TYP_ ----------------- P.01 sm1*31 V^ tbLOROb bi WTA , =A, Daite. 9.19*12 1 EASEMENT LEVEL PLAN A1.0 SCALE; 1/4 " =1' -0" ., 0 a ,5 F t G z " 4 {ct Daite. 9.19*12 1 EASEMENT LEVEL PLAN A1.0 SCALE; 1/4 " =1' -0" ., 0 a ,5 GENERAL NOTES: 223 BEAVER DAM DECK REFURBISH JOB #0109 -12 DESIGN CRITERIA: DECK LIVE LOAD: 100 PSF DECK DEAD LOAD: 12 PSF BASIC WIND SPEED (3 SEC GUST): 90 MPH WIND EXPOSURE: B SEISMIC DESIGN CATEGORY: C IBC EDITION: 2009 FOUNDATION DESIGN: 1. THIS FOUNDATION HAS BEEN DESIGNED BASED ON THE RECOMMENDATIONS SET FORTH IN GEOTECHNICAL REPORT #112 300A BY HP GEOTECH, INC. CONSTRUCTION OF THIS FOUNDATION SHALL FOLLOW THE REQUIREMENTS FROM THIS REPORT. 2. DESIGN OF FOOTINGS IS BASED ON A MAXIMUM ALLOWABLE BEARING PRESSURE OF 2000 PSF. 3. SOIL VALUES AND CONDITIONS SHALL BE VERIFIED BY A REPRESENTATIVE OF THE GEOTECHNICAL ENGINEER AND ANY REQUIRED SPECIAL INSPECTION FOR SOILS AS INDICATED IN SECTION 1704.7 OF THE 2009 IBC. REPORT ANY DISCREPANCIES FROM THE ORIGINAL FINDINGS TO THE STRUCTURAL ENGINEER, 4. FOOTINGS SHALL BE PLACED BELOW FROST DEPTH ON UNDISTURBED SOIL OR ON STRUCTURAL FILL COMPACTED AS REQUIRED BY THE GEOTECHNICAL ENGINEER. 5. PROVIDE PERIMETER FOUNDATION DRAINS PER THE GEOTECHNICAL ENGINEER RECOMMENDATIONS. STRUCTURAL MASONRY: 1. LOAD BEARING CONCRETE MASONRY UNITS SHALL CONFORM TO ASTM C90 STANDARDS 2. MORTAR SHALL CONFORM TO ASTM 0270 AND ARTICLES 2.1 AND 2.6 A OF TMS 602/ACI 530.1 /ASCE 6, EXCEPT FOR MORTARS LISTED IN SECTION 2103.9,2103. 10 AND 2103.11 OF THE 2009 IBC. DO NOT USE ADMIXTURES UNLESS APPROVED BY STRUCTURAL ENGINEER. 3. GROUT SHALL COMPLYTO ARTICLE 22 OF TMS 602/ACI530.1 /ASCE 6. UNLESS OTHERWISE REQUIRED, PROPORTION AND MIX GROUT OTHER THAN SELF - CONSOLIDATING GROUT IN ACCORDANCE WITH THE REQUIREMENTS OF ASTM C476. MINIMUM GROUT COMPRESSION STRENGTH EQUAL OR EXCEEDS fm, BUT NOT LESS THAN 2000 PSI. 4. MASONRY SHALL HAVE A MINIMUM 28 DAY COMPRESSION STRENGTH OF fm =1500 PSI. 5. PROVIDE (2) - #5 BARS EXTENDING A MINIMUM OF 2 FEET BEYOND EDGES OF OPENINGS (BOTH VERTICAL GROUTED CELLS AND HORIZONTAL GROUTED BOND BEAMS). 6. MASONRY WALLS SHALL BE GROUTED IN CELLS CONTAINING STEEL REINFORCING UNLESS AUTHORIZED BY THE STRUCTURAL ENGINEER. 7. STRUCTURAL MASONRY SHALL BE LAID UP RUNNING BOND WITH EXPOSED JOINTS TOOLED. REINFORCED CONCRETE: 1. CONCRETE DESIGN IS BASED ON THE MOST CURRENT PUBLICATION OF "BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE" (ACI 318). 2. STRUCTURAL CONCRETE SHALL HAVE A MINIMUM 28 DAY COMPRESSIVE STRENGTH OF 3000 PSI. 3. CONCRETE SHALL BE PROPORTIONED USING TYPE 1 -11 SULFATE RESISTANT CEMENT. DO NOT USE ADMIXTURES CONTAINING CHLORIDE SALTS. 4. FOR COLD WEATHER CONCRETING PROCEDURES REFER TO THE "ACI MANUAL OF CONCRETE PRACTICE." 5. EXPANSION ANCHORS SHALL BE LOCATED NO LESS THAN 6 BOLT DIAMETERS FROM CONCRETE EDGES AND SPACED AT NO LESS THAN 12 BOLT DIAMETERS UNLESS NOTED OTHERWISE. 6. CONCRETE FLOOR SLABS ON GRADE SHALL HAVE SAWN OR TOOLED CONTROL JOINTS AT A MAXIMUM SPACING OF 12 FEET IN EACH DIRECTION. IF POSSIBLE, LOCATE CONTROL JOINTS ALONG COLUMN GRIDLINES. 7. CONCRETE COVERAGE FOR REINFORCING STEEL (ACI 318 -95): CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH: 3" CONCRETE EXPOSED TO EARTH OR WEATHER: #6 BAR THROUGH #18 BAR: 2" #5 BAR, W31 OR D31 WIRE, AND SMALLER: 1 1/2" CONCRETE NOT EXPOSED TO WEATHER NOR IN CONTACT WITH GROUND: a. SLABS, WALLS AND JOISTS ( #11 BAR AND SMALLER): #14 AND NO 18 BARS: 1112, #11 BAR AND SMALLER: 3/4" b. BEAMS AND COLUMNS: PRIMARY REINFORCEMENT, TIES, STIRRUPS, SPIRALS: 11/2, REINFORCING STEEL: 1. EXCEPT WHERE OTHERWISE NOTED, REINFORCING BARS SHALL BE GRADE 60 EXCEPT TIES, FIELD BENT BARS AND BARS TO BE WELDED WHICH MAY BE GRADE 40. ALL REINFORCING BARS SHALL CONFORM TO ASTM SPEC. 2. FOR BARS #8 AND SMALLER, LAP BARS 36 DIAMETERS AT SPLICES IN CONCRETE. DO NOT WELD OR USE MECHANICAL SPLICING DEVICES UNLESS APPROVED BY ENGINEER. 3. HORIZONTAL BARS SHALL BE CONTINUOUS OR LAPPED WITH CORNER BARS AT CORNERS. PROVIDE (2) - #5 BARS EXTENDING A MINIMUM OF 2 FEET BEYOND EDGE OF ALL OPENINGS OR STEPS. 4. EXTEND REINFORCING STEEL A MINIMUM OF 2 FEET THROUGH COLD JOINTS. COORDINATE ALL COLD JOINT LOCATIONS WITH ENGINEER. 5. WELDED WIRE FABRIC SHALL CONFORM TO ASTM SPEC. A -185. LAP WELDED WIRE FABRIC A MINIMUM OF TWO FULL MESH GRIDS. STRUCTURAL WOOD FRAMING: 1. EXCEPT WHERE NOTED OTHERWISE, ALL 2" NOMINAL LUMBER EXCEPT STUDS SHALL BE DOUGLAS FIR -LARCH #2 AND BETTER. ALL SOLID TIMBER POSTS AND BEAMS 3" NOMINAL AND WIDER SHALL BE DOUGLAS FIR -LARCH #2 UNLESS NOTED OTHERWISE ON PLAN. 2. BOLTS USED IN FRAMING CONNECTIONS SHALL BE INSTALLED WITH STANDARD WASHERS AND NUTS. 3. REFER TO THE 2009 IRC TABLE R602.3(1) OR 2009 IBC TABLE 2304.9.1 FOR MINIMUM FASTENING SCHEDULE. A COPY OF THIS TABLE CAN BE PROVIDED UPON REQUEST. AS STATED IN SECTION 2304.9.5 OF THE 2009 IBC SECTION 2304.9.5: FASTENERS IN CONTACT WITH PRESERVATIVE - TREATED AND FIRE - RETARDANT - TREATED WOOD SHALL BE OF HOT- DIPPED ZINC - COATED GALVANIZED STEEL, STAINLESS STEEL, SILICON BRONZE OR COPPER. FASTENINGS FOR WOOD FOUNDATIONS SHALL BE AS REQUIRED IN AF &PA PWF. 4. UNLESS NOTED OTHERWISE, STEEL CONNECTORS SHALL BE USED TO JOIN RAFTERS, JOISTS AND BEAMS SUCH AS SIMPSON STRONG -TIE CONNECTORS OR EQUIVALENT. CONNETORS THAT ARE USED IN EXTERIOR APPLICATIONS AND IN CONTACT WITH PRESERVATIVE - TREATED WOOD SHALL HAVE COATING TYPES AND WEIGHTS IN ACCORDANCE WITH THE TREATED WOOD OF CONNECTOR MANUFACTURERS' RECOMMENDATIONS OR IN ACCORDANCE TO IBC SECTION 2304.9.51. STRUCTURAL STEEL: 1 STRUCTURAL STEEL ROLLED SHAPES SHALL BE ASTM A50. TUBE SHAPES SHALL BE ASTM A500 GRADE B. PIPES SHALL BE ASTM A53 GRADE B OR ASTM A501. 2, ALL BOLTS USED IN STEEL FRAMING SHALL CONFORM TO ASTM SPECIFICATION A325. ANCHOR BOLTS AND BOLTS (INCLUDING LAGS) USED IN TIMBER CONNECTIONS MAYBE ASTM A307. 3. TORQUE INSPECTION SHALL BE PROVIDED AS REQUIRED BY THE BUILDING INSPECTOR. 4. ALL WELDING SHALL BE DONE BY AN AWS CERTIFIED WELDER. FIELD WELDS MAY REQUIRE SPECIAL INSPECTION IN ACCORDANCE TO IBC SECTION 1704.3 AND LOCAL BUILDING OFFICIALS. BACKFILLING PROCEDURES: 1. VERIFY TYPE OF FILL WITH GEOTECHNICAL ENGINEER. GROUT: 1. GROUT BENEATH COLUMN BASE PLATES AND STEEL BEAM BEARING PLATES SHALL BE NON- SHRINK, NOWMETALIC GROUT WITH A MINIMUM COMPRESSIVE STRENGTH OF 2500 PSI. GENERAL REQUIREMENTS: 1. CHECK ALL DIMENSIONS AGAINST ARCHITECTURAL DRAWINGS PRIOR TO CONSTRUCTION. DO NOT SCALE DRAWINGS. CONTACT ENGINEER IF DISCREPANCIES IN DIMENSIONS ARE DISCOVERED. 2. THE STRUCTURAL DRAWINGS DESCRIBE THE COMPLETED STRUCTURE. THESE DRAWINGS HAVE BEEN PREPARED FOR THE USE OF A QUALIFIED CONTRACTOR WITH EXPERIENCE IN THE CONSTRUCTION SYSTEMS AND TECHNIQUES DESCRIBED. THE CONTRACTOR SHALL PROVIDE ADEQUATE SHORING AND BRACING IN THE PROPER SEQUENCE, AS MAY BE REQUIRED TO ACHIEVE THE FINAL COMPLETED STRUCTURE. THE SEQUENCE OF CONSTRUCTION IS THE RESPONSIBILITY OF THE CONTRACTOR. CONSULT WITH THE ENGINEER FOR SHORING DESIGN AND RECOMMENDATIONS (NOT IN CONTRACT). 3. THE CONTRACTOR IS RESPONSIBLE FOR THE MEANS, METHODS SEQUENCES AND PROCEDURES FOR CONSTRUCTION OF THIS PROJECT. NOTIFY STRUCTURAL ENGINEER OF ERRORS OR OMISSIONS IN THE CONSTRUCTION DOCUMENTS IMMEDIATELY. DO NOT PROCEED UNTIL ERRORS OR OMISSIONS ARE RESOLVED. COORDINATE REQUIREMENTS FOR ALL PENETRATIONS THROUGH STRUCTURAL MEMBERS WITH STRUCTURAL ENGINEER, JOBSITE SAFETY IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR. 4. OBSERVATION VISITS BY THE STRUCTURAL ENGINEER ARE FOR DETERMINATION OF GENERAL COMPLIANCE WITH THE CONSTRUCTION DOCUMENTS, THIS OBSERVATION VISIT IS NOT AN INSPECTION. THE CONTRACTOR SHALL CONTACT THE ENGINEER AT THE APPROPRIATE TIME TO SCHEDULE THIS VISIT. 5. IF NEW CONSTRUCTION ADJOINS AN EXISTING STRUCTURE, THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING DIMENSIONS, ELEVATIONS AND ALL EXISTING CONDITIONS, UNDERPINNING AND SHORING OF EXISTING STRUCTURES SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. CONSULT WITH THE ENGINEER FOR SHORING DESIGN AND RECOMMENDATIONS (NOT IN CONTRACT). 6. WHILE EVERY EFFORT IS MADE TO PROVIDE A COMPLETE AND ACCURATE SET OF CONSTRUCTION DOCUMENTS, ERRORS OR OMISSIONS MAY OCCUR. RELEASE OF THESE DRAWINGS ANTICIPATES CONTINUED COOPERATION AND COMMUNICATION BETWEEN THE CONTRACTOR, ARCHITECT AND ENGINEER TO PROVIDE THE BEST POSSIBLE STRUCTURE. A.B. ANCHOR BOLT ADJ, ADJACENT ALT. ALTERNATE ARCH. ARCHITECT BD. BOARD BLKG. BLOCKING BM. BEAM BM, PKT. BEAM POCKET BRG. BEARING CANT. CANTILEVER CLR. CLEAR CMU CONCRETE MASONRY UNIT COL, COLUMN CONC. CONCRETE CONT. CONTINUOUS C.P. CRIPPLE POST DWL. DOWEL (E) EXISTING EA. EACH EQ. EQUAL EXP. EXPANSION EXSTG. EXISTING F.D. FLOOR DRAIN FTG. FOOTING G.L. GLUED LAMINATED HDR. HEADER HORIZ. HORIZONTAL INFO. INFORMATION JSTS. JOISTS . K.S. KING STUD LLV LONG LEG VERTICAL LONGIT. LONGITUDINAL LTWT. LIGHTWEIGHT LVL LAMINATED VENEER LUMBER MANF. MANUFACTURER (N) NEW O.C. ON CENTER R PLATE REF. REFERENCE REINF. REINFORCING SCHED. SCHEDULE S.I.P. STRUCTURAL INSULATED PANEL STL. STEEL T.B. THROUGH BOLT T &G TONGUE & GROOVE TO TOP OF TOF TOP OF FOOTING TOW TOP OF WALL TRANSV. TRANSVERSE TRTD. TREATED TS TUBE STEEL TYP. TYPICAL VERT. VERTICAL VIF VERIFY IN FIELD W.P. WATERPROOF W/ WITH CONNECTION SCHEDULE ® STL. L SEE 2/S2 �B I L 6X6x5/16 (SEE 1/S2) C 1/4" PLATE "T" EA. SIDE OF BM. SEE 1 /S2 .i SIMPSON ABU88 (SEE 1 /S1) • • • VIF CMU COURSE & BM. HT. (SEE 3/S2) Z 0 c!> Qlj L � I L_ Q CONN: SIMPSON ABU88 W/ (2) -5/8 "0 x 5" SIMPSON TITEN HD (THDB62500H) 0 T -.----.-- -- EXTEND CMU COL. TO BOT. OF (E) ROOF BM. ABOVE F_ DECK • �p (N) V -4" x V -4 " FULLY GROUTED CMU PIER (4)45's VERT. FULL HT. (ONE EA. CORNER) STD. WIRE JOINT REINF. @ 16" (4) - #5 DWLS. x 6" REF. SCHEDULE SHEET S1 FOR REINF. INFO. POST PER PLAN NOTCHED AT BASE IF REQ'D TO FIT IN BASE CONN. SIDES (DO NOT OVERCUT NOTCH) (2) - #5 DWLS. x �?_ 6" REF, SCHEDULE SHEET S1 FOR REINF. INFO. A'ilf 1 S1 1' -11 z° 9' -421" L- INDICATES (N) 120 CONC. PIER ON (N) CONC. SPREAD FTG. PER SCHED. THIS SHEET L._ IF I{ { I INDICATES EXSTG. i L- E i CMU FOUNDATION L -- - - { j WALL (BELOW) II I INDICATES EXSTG. { { CONC. FTG., TYP. { { { li ij i it li it i iltq li i i i li it li it li i� { { EXSTG. I j ( EXSTG. SLAB ON ( { I{ i CRAWLSPACE i GRADE { { li {� li i� II 11 li II f !I - li ll it lii ll I ( { I INDICATES EXSTG. CMU { { WA BELOW) ION Ij jl � II li fl ii I,i II I{ { INDICATES EXSTG. I{ I I I CONC, FTG., TYP. - - _ - _ _.....L i m i _ ___ LL NOTE: VERIFY ALL DIMENSION � -- } WITH EXISTING CONDITIONS PRIOR TO CONSTRUCTION o T . ARYL INDICATES (N) 12 "0 CONC. PIER ON (N) CONC. SPREAD FTG. PER SCHED. THIS SHEET F-1- -7, - L5 3 �J 9' -1" li it (N) 1' -4" x V-4" CMU COL. FULLY { i GROUTED W/ #5's VERT. FULL HT. @ ( i EA. CORNER (4 TOTAL) & STD. WIRE JOINT REINF. @ 16" HORIZ. SPACING B II it F 2 (E) CMU COL. TO REMAIN S1 L. 8' -6"' PLAN NOTES: 1. 0 INDICATES CONNECTION TYPE, REFERENCE SCHEDULE SHEET S1 2. NEW CONSTRUCTION INDICATED( ), EXISTING CONSTRUCTION INDICATED ( -} 3. DO NOT SCALE DRAWINGS. VERIFY ALL DIMENSIONS WITH ARCHITECT AND EXISTING CONDITIONS • r •• "s leffloyfflilem �I • -are] 11 s .i ! M! • • • D o� A >E a► .r NON 4 s .i • i .s • .r D o� A >E NON 4 s .i i D o� A >E i� rn � • ' i E • NON 4 i� rn � • ' i E • 4 i 1i i� rn � • ' i E • (E) EXTERIOR WALL (E) FLOOR /DECK JOISTS _A_ 7i (E) FLR. BM (E) CMU WALL m (E) 2x8 DECK JOISTS ftin n n of vn MAKi -t n 1, .f -T.. t v ...t.., � �t ��v ' SIDE OF (E) DECK BM. W/ TWO ROWS 5/8 10 T.B.'s @ 16" (8 MIN.) Z uG G C t U DECK FRAM NQT SHOWN FOR CLARITY (E) CMU WALL F cv LLB d Go Y� �� 2 t, ' (E) DECKING (E) 2x8 DECK JOISTS (N) 2x8 BLKG. PANEL �: :' (N) DBL. 4x10 PER ffi��il (E) POST PER PLAN (E) POST PER PLAN (BEYOND) V -4" x 1' -4" FULLY TOUTED CMU R (SEE 2/S1) 10x10 DECK BM. CONN: BRG. L SIM TOD :RIFY CMU COURSE LAYOUT I EXACT BM. HT. AND )NTACT ENG. FOR STL. )NN. ms 6x10 BM. PER PLAN 0 CONN: SIDE: L 4x4x1/4x0' -11 1/2 W/ (2) -5/8" O x 4" TITED HD & (1) -1/2 "O x 4" LAG BAT: L 4x4x1/4x0' -5 1/2 W/ (1) -5/8 "0 x 4" TITED HD & (1) -1/2 "0 x 4" LAG 411 atl T VERIFY ALL EDGE DISTANCES • � FROM CENTER OF BOLT TO EDGE OF BLOCK AND �1 CONTACT ENG. IF DIFFERENT s THAN THAT SHOWN an (N) L 6x6x5/16 x 0' -4 EA. SIDE OF BM. W/ (1) -1/2 "O T.B. & (1) -1/2 "0 x 4" LAG (2 TOT.) 1,11 vr.3" .. 72"' .3" J 141" NI t Q CONN: 1/4" I}' x DIM's SHOWN W/ (6) -3/4 "0 T.B.'s 2" L L 2" *'-� — SOLID BLKG. BTWN. (N) DBL. 4x10 @ BRG. (N) L 6x6x5/16 x 0' -4 EA. SIDE OF BM. W/ (1) -1/2 "O T. B. & (1) -1/2 "0 x 4" LAG (2 TOT.) 9 CONN: 1/4" I_x DIM's SHOWN W/ (6) -3/4 "0 T.B.'s SCALE: =1 °v REUSE EXSTG. COL.'s SISTER (N) 4x10 TO EA. SIDE OF (E) 6x8 W/ (2) -5/8 "0 T.B.'s @ 16" (8 MIN.), TYP. INDICATES EXSTG. CANT. 6x8 S2 w Q I INDICATES EXSTG. I FLOOR JOIST, TYP. f � INDICATES EXSTG. TO PLYWD. _ _ 4 �.` _.. ��. � . .�. -i4­1 GMU FOUNDATION I ff WALL (BELOW) } L Illjl_xf I� �Q /X� ®_____ f co Lu INDICATES EXSTG. INTERIOR WALLS I f l NOTE: NOT ALL INTERIOR i► f I ____1 T_ WALLS AND- STRIMTURE ARE SHOWN ON THIS PLAN (f ( f II f i i I 1 1 I I I II _VIF ___ f l § f I I TO PLYWD. f f ._i L ------ ........... _......._.. __-_ ._. - _._. _... _. 11 -------- Y.......... - ......._ .......... .........._. _ _._....._.. _ ._......._..........._.. _ ._... _.... _ J i - --i f I --4 F— w- SISTER (N) 2x8 TO (E) 2x8 I -- — - -- — - -- 1 w L JOIST W/ (3) -10d NAILS @ 16" — 1 U z w -- —�- VIF f w �� _ TO DECKING INDICATES EXSTG. _._W w 10x10 BM. TO �� ¢ (u REMAIN, TYPE °D Ui w® tr W ,- 0 0 REUSE EXSTG. BM's. �r�,o NOI-110 NO & COL.'s �, ff, (N) 16" x 16" CMU COL. FULLY (E) CMU COL. TO REMAIN j GROUTED W/ #5's VERT. @ EA. CORNER (4 TOTAL) & STD. WIRE JOINT REINF. # 24 "' MAIN LEVEL DECK FRAMING PLAN _ SCALE. 1/4" =V_0 PLAN NOTES: 1. NEW DECK BEAMS ARE DROPPED UNLESS NOTED "FLUSH" 2. EXSTG. POSTS CONTINUOUS BELOW ARE INDICATED: F EXSTG. POSTS FROM ABOVE NOT CONTINUOUS BELOW ARE INDICATED: rl 3. Q INDICATES CONNECTION TYPE. REFERENCE SCHEDULE SHEET S1 4. NEW CONSTRUCTION INDICATED( }, EXISTING CONSTRUCTION INDICATED 5. DO NOT SCALE DRAWINGS. • 0 i .0 a. - • � •r �1 s r • it • 0 i t • - t � t �1 s • 0 i PROJECT: 010• DRAWN BY: TFA REVIEWED BY: JPL w w 0• Nme Bi 1 t �1 PROJECT: 010• DRAWN BY: TFA REVIEWED BY: JPL w w 0• Nme Bi 1 �1 PROJECT: 010• DRAWN BY: TFA REVIEWED BY: JPL w w 0• Nme Bi 1