Loading...
HomeMy WebLinkAboutDRB120371 approved208'-6" Fin Floor Elev. TV TV GUESTLAUNDRY 121 GUESTWET BAR 103 GUESTBATH108 GUESTBEDROOM #2107 GUESTBEDROOM #1105 W.C. SteamShwr. W.C. HIGHWINDOW King King Luggage Ref. DW Luggage Built-inCab. Built-in Cab. POCKETDOOR 204'-0"Fin Floor Elev. 214'-2-3/8"CushionStorage(Floor above)/Mechanical Crawl Space(less tha n 5'-0" tall) SPORTSSTOR.119 Parking#1 110 Parking#2111 Built-inLockers TV #4 Recessed Area at conc. slab103" x 235" Fed Ex/ Mail 208'-6"Fin Floor Elev. Bench/cubbies/ hooks POOLEQUIP. 116 206'-6"Fin Floor Elev. (less than 5'-0" tall) Planter Glass Floor of Pool @Ceiling HALL 115 BACKSTAIR 114 MUDROOM 113 STAIRS 112 Harding Steel VTS-2/ ParkingLift Platform "Lid" 234" x 102"Pit Opening 97" x 229" x 21"(d)Platform Welment Width 94" x 224" Recessed Area at conc. slab103" x 235" 208'-6" Fin Floor Elev. UP 7 R'S @ 7.71"6 T'S @ 1'-0"DN CRAWLSPACE 117 (less than 5'-0" tall) 16 R ' S @ 7 . 5 " 15 T ' S @ 1 ' - 0 " DN22 R ' S @ 7 . 6 " 21 T ' S @ 1 ' - 0 " 208'-6" Fin Floor Elev. ENTRYFOYER 101 Bench/cubbies/hooks 8211'-6"Fin Grade 8204'-0"Fin Grade 8208'-6"Fin Grade WETSTOR. 120 8208'-6"Fin Grade 8210'-6"Fin Grade ret. wall 8212'-6" Fin Grade Standpipe Elec.Meter GasMeter Flo o r A b o v e ret. wall Flo o r A b o v e CRAWLSPACE118 Floor Above GLASSFLOOR STONE VENEER 8209'-6" Fin Grade UP 113'-6" BOT. OFGLASS POOL HALL109 STONE VENEER (less than 5'-0" tall) FLOOR ABOVE CP ST CP ST ST CP STEPOXYCOATING ST ST 113'-6"Fin Floor Elev. LocksetDoor bike/ ski/snowboard racks F.D. #3 #2 #1 CHANNEL GLASS POOL COVER SITE WALLSPER LANDSCAPEPLAN SITE WALLS PER LANDSCAPE PLAN ELEV. 102 FIREPIT HEATERSABOVE CRAWLSPACE118 Platform "Lid" 234" x 102"Pit Opening 97" x 229" x 21"(d)Platform Welment Width 94" x 224" Harding SteelVTS-2/ ParkingLift FD 7'-0" dia.shaft Planter Planter STST ST CO 6'-1012" 6'-6 58" 4'-1 14" 4'-10" 3'-8" 3'- 2 " 7'-6" 5'-478"26'-214" 23' - 1 12" 27' - 3 " 13'-414" 3'- 5 " 23'-4" 6'-114" 14'-8" 11' - 1 1 14" 11' - 1 1 14" 14'-878" 3'-2 " 3'-912" 30 ' S T R E A M S E T B A C K 30 ' S T R E A M S E T B A C K 15' S I D E S E T B A C K 20' FRONT SETBACK 20' FRONT SETBACK W/D 5'-6" Steam Shwr. FD GUESTBATH 106 ST CP Pull down attic stair 213'-7-1/8"Bot. of Clg. Structure 217'-5-7/8"Bot. of Clg. Structure 228'-4" Bot. of Clg. Structure 208'-6"Fin Floor Elev.217'-5-7/8"Bot. of Flr. Structure 217'-5-7/8" Bot. of Clg. Structure 208'-6"Fin Floor Elev.217'-5-7/8"Bot. of Clg. Structure 2011'-6"Bot. of Clg. Structure Elev. 206'-6"Fin Floor Elev.2011'-6"Bot. of Clg. Structure Elev. 206'-6"Fin Floor Elev.2011'-6" Bot. of Clg. Structure Elev. 15' REA R S E T B A C K 15 ' S I D E S E T B A C K SITE WALLSPER LANDSCAPEPLAN BASEMENT WALL SURFACE CALCULATIONS: HATCH INDICATES AREA BELOW GRADE. TOTAL WALL SURFACE AREA = 3563sf AREA BELOW GRADE = 3563sf PERCENT BELOW GRADE = 100% = DEDUCTION TOTAL FLOOR AREA = 2,436sf * .00 = 0sf LOWER LEVEL GRFA CALCULATIONS: BASEMENT LEVEL = 0sf GROUND LEVEL = 2,436sf - 600sf GARAGE CREDIT = 1,836sf MAIN LEVEL = 249sf + 2204sf = 2,453sf UPPER LEVEL = 1,069SF TOTAL = 5,358sf SITE AREA = 12,580sf GRFA = 5,580 ALLOWED 5,580sf -5,358sf = 222 sf GRFA REMAINING PRO P E R T Y L I N E PROPERTY LINE PR O P E R T Y L I N E PR O P E R T Y L I N E REA R S E T B A C K 1 5 ' FRONT SETBACK 20' SI D E S E T B A C K 1 5 ' ST R E A M S E T B A C K 3 0 ' F R O M C T R L I N E PRO P E R T Y L I N E ELEV. 001 7'-0" dia. shaft CRAWLSPACE 000 188'-2"Fin Floor Elev.(less than 5'-0" tall) LADDER TOFLOOR ABOVE LINE OF FLOORABOVE, VFYSIZE MECH. CHASE ABOVETO ROOF MECH. CHASE TOGROUND FLOOR MECH. CHASE TOMAIN ROOF 8'-4"PIT DEPTHPER MFR.W/ SUMP PIT AT BASE 186'-2"T.O. SLAB Elev. 32'-4" 19' - 1 0 " 13'-778" 10' - 3 14" 193'-2"Bot. of Clg. Struct.(less than 5'-0" tall) 15' S I D E S E T B A C K 20' FRONT SETBACK 20' FRONT SETBACK 30 ' S T R E A M S E T B A C K 15' RE A R S E T B A C K 15' S I D E S E T B A C K GAME 016 DVP TV DN Built-in Seating Built-inSeating Speakers u/cref.dw WETBAR014 (8) THEATRE017 193'-3"Fin Floor Elev. 192'-7"Fin Floor Elev. UP FD Shwr. BATH015 popcorn Games Built-inCab. HWCP WINESTOR.012 TV Built-in(Locked) Storage (1500)w/ library ladder Pocket dr. EUROFOOSBALL013 ST CP STONE VENEER ref. STORAGE005 Parking#3006 Parking#4007 LIFT CONTROLS 009 194'-6"Fin Floor Elev. EPOXYCOATING ST ST HW EPOXYCOATING ST Built-inCab. 20 MIN.RATED GLASS STAIRS 002 UP 22 R ' S @ 7 . 6 " 21 T ' S @ 1 ' - 0 " MECH.CRAWL003 ELEV.EQUIP. 004 OFFICE 010 Built-in(Locked)Storage (500)w/ library ladder WineDisplay WINEHALL011 Glass Floorabove194'-6"Fin Floor Elev. ELEV. 001 7'-0" dia.shaft 194'-6"Fin Floor Elev. Recessed Area at conc. slab103" x 235" Platform "Lid" 234" x 102"Pit Opening 97" x 229" x 21"(d)Platform Welment Width 94" x 224" Harding SteelVTS-2/ ParkingLift Harding SteelVTS-2/ ParkingLift MECH. MECH. MECH. 12'-1134" 17 ' - 0 " 12'-512" 11' - 8 12" 10' - 1 1 12"21'-0"23'-478" 14 ' - 3 78" 25'-814" 26' - 9 " 24' - 3 34" LADDERDOWN1 HR. MECH.ACCESS DOOR/12 SQ./FT.OPENING 13' - 9 14" 11' - 2 78" 6'-278"7'-6" 5'-714" 18'-612" 204'-11-7/8"Bot. of Clg. Struct. 194'-6"Fin Floor Elev.205'-6"Bot. of Clg. Struct. 205'-6"Bot. of Clg. Struct. 205'-6"Bot. of Clg. Struct. 202'-1-1/4"Bot. of Clg. Struct. 15' S I D E S E T B A C K 20' FRONT SETBACK 20' FRONT SETBACK 30 ' S T R E A M S E T B A C K 15' REA R S E T B A C K 15 ' S I D E S E T B A C K W/D W/D RIDGE BEAM ABOV E RIDGE BEAM ABOVE RIDGE BEAM ABOVE King TUB Bookshelves WIC306 Hanging 229'-0"Fin Floor Elev. HIGHWINDOWS Ref.DW Hanging SteamShwr. W.C. W.C./ BIDET DN 17 R ' S @ 7 . 4 1 " 16 T ' S @ 1 ' - 0 " OPEN TOSTAIRS BELOW ELEV. 302COFFEEBAR 304 READING 305 HALL303 MASTERBATH 307 MASTERBEDROOM 308 GOREVIEW GAS "RIBBON"FP 60" T&C HIGHWINDOWS DOOR W/FR. BALCONY(STREAM) HWTILE HW HW HWHW 229'-0"Fin Floor Elev. 229'-0"Fin Floor Elev. 223'-3"Fin Floor Elev. STAIRS301 SOD ROOF LocksetDoor 6" medicine cabinet ROOF DECK WITH HEATED PAVERS WINDOWSABOVE CHANNEL GLASS CORNERWINDOW CORNERWINDOW 229'-0"Fin Floor Elev. Mirror nicheBench 7'-0" dia.shaft CORNERWINDOW SOD ROOF 14'-814" 16 ' - 7 14" 18'-534" 9'-8 34" 11'-11" 10'-9" 10' - 2 34" 3'-2"3'-2 " 6'-114" 5'-834"5'-1 14" 6'-1 0 58" 240'-6-3/8"Bot. of Clg. Structure(Gable Peak) 241'-10-3/4"Bot. of Clg. Struct.(Gable Peak) 229'-0"Fin Floor Elev.241'-10-3/4"Bot. of Clg. Struct.(Gable Peak) 15 ' S I D E S E T B A C K 20' FRONT SETBACK 20' FRONT SETBACK 15' RE A R S E T B A C K 15 ' S I D E S E T B A C K 30 ' S T R E A M S E T B A C K SOLAR PANELS(S) SOLAR PANELS(N) 4:12 4:12 METAL SNOW-GUARD LINE OF WALL, TYP. LINE OF RIDGE RDOS 2% 2% ROOF CURB FLAT ROOF METAL SNOW-GUARD RDOS 2% 2%2% LINE OF WALL, TYP. LINE OF WALL, TYP. LINE OF ROOF, TYP. 2:12 INTERNAL SCUPPERW/ HEAT TAPE &DOWNSPOUT ROOF CURB METAL SNOW-GUARD SOLAR PANELS(N) 3:122.6:12 METAL SNOW-GUARD SOLAR PANELS(N) SOLAR PANELS(S) SOLAR PANELS(S) 4:12 4:12 4:12 4:12 4:12 4:12 METAL SNOW-G U A R D METAL SNOW-GUARD METAL SNOW-GUARDMETAL SNOW-GUARD METAL SNOW-GUARD SOD ROOF FLAT ROOF FLAT ROOF SOD ROOF EDGE OF PARAPET,TYP. RDOS 2% 2% ROOF DECK (HEATED PAVERS) 15 ' S I D E S E T B A C K 20' FRONT SETBACK 20' FRONT SETBACK 2'- 9 18" 1'-6 12" 2'-6"2'- 6 " 3'-212" 2'-6" 2'- 6 " 6" 6" 3'-1158" 1'-1034"2'-1 1 14" 1'- 1 18"1014" 2'-6" 1'-0 " 2'-6" 2'-0 " 2'-6" 2'-0 " 2'-6" 1'-6"1'-0 " 1'- 0 " 2'-6" 2'- 0 " 1'-818" 15' REA R S E T B A C K 15 ' S I D E S E T B A C K 30 ' S T R E A M S E T B A C K NO ROOF OVERHANG EXCEEDS 4'-0" 1/16" = 1'-0" LOWER LEVEL WALL DEDUCTION AND FLOOR AREA PLAN = 2,436sf7 PROJECT: 71 0 W E S T L I O N S H E A D C I R C L E - U N I T A V A I L . , C O L O R A D O 8 1 6 5 7 9 7 0 . 4 7 7 . 2 9 9 0 MI L L C R E E K C I R C L E RE S I D E N C E / L O T # 3 DRAWN BY: DATE: REVISIONS: xxxx VA I L , E A G L E C O U N T Y CO L O R A D O HB 07.27.12 NO T F O R C O N S T R U C T I O N 1/8" = 1'-0" BASEMENT WALL DEDUCTIONS8 1/16" = 1'-0" GROUND LEVEL = 2,436 sf31/16" = 1'-0" SUBGRADE CRAWL SPACE LESS THAN 5'-0" HEIGHT1 08.08.2012 HB 1/16" = 1'-0" BASEMENT LEVEL = 2,436 sf2 1/16" = 1'-0" MAIN LEVEL = 2,453 sf41/16" = 1'-0" UPPER LEVEL = 1,069 sf51/16" = 1'-0" ROOF PLAN6 09.10.2012 HB W/D PRO P E R T Y L I N E PROPERTY LINE PR O P E R T Y L I N E PR O P E R T Y L I N E REA R S E T B A C K 1 5 ' FRONT SETBACK 20' S I D E S E T B A C K 1 5 ' ST R E A M S E T B A C K 3 0 ' F R O M C T R L I N E PRO P E R T Y L I N E W/D W/D SOLAR PANELS(S) SOLAR PANELS(N) 4:12 4:12 METAL SNOW-GUARD LINE OF WALL, TYP. LINE OF RIDGE RDOS 2% 2% ROOF CURB FLAT ROOF METAL SNOW-GUARD RDOS 2% 2%2% LINE OF WALL, TYP. LINE OF WALL, TYP. LINE OF ROOF, TYP. 2:12 INTERNAL SCUPPER W/ HEAT TAPE & DOWNSPOUT ROOF CURB METAL SNOW-GUARD SOLAR PANELS(N) 3:122.6:12 METAL SNOW-GUARD SOLAR PANELS(N) SOLAR PANELS(S) SOLAR PANELS(S) 4:12 4:12 4:12 4:12 4:12 4:12 METAL SNOW- G U A R D METAL SNOW-GUARD METAL SNOW-GUARDMETAL SNOW-GUARD METAL SNOW-GUARD SOD ROOF FLAT ROOF FLAT ROOF SOD ROOF EDGE OF PARAPET, TYP. RDOS 2% 2% ROOF DECK (HEATED PAVERS) 15 ' S I D E S E T B A C K 20' FRONT SETBACK 20' FRONT SETBACK 2' - 9 18" 1'- 6 12" 2'-6"2'- 6 " 3'-212" 2'-6" 2' - 6 " 6" 6" 3'-1158" 1'-1034"2' - 1 1 14" 1'- 1 18" 10 14" 2'-6" 1'- 0 " 2'-6" 2'- 0 " 2'-6" 2'- 0 " 2'-6" 1'-6"1'- 0 " 1'- 0 " 2'-6" 2'- 0 " 1'-818" 15' R E A R S E T B A C K 15 ' S I D E S E T B A C K 30 ' S T R E A M S E T B A C K NO ROOF OVERHANG EXCEEDS 4'-0" SITE AREA = 12,580sf SITE COVERAGE= 2516 SQ./FT ALLOWED PROPOSED SITE COVERAGE=2515 SQ./FT 2516 SQ./FT -2515 SQ./FT= 1 SQ/ FT OF SITE COVERAGE REMAINING 1/16" = 1'-0" OVERALL SITE COVERAGE = 2,515sf6 PROJECT: 71 0 W E S T L I O N S H E A D C I R C L E - U N I T A V A I L . , C O L O R A D O 8 1 6 5 7 9 7 0 . 4 7 7 . 2 9 9 0 MI L L C R E E K C I R C L E RE S I D E N C E / L O T # 3 DRAWN BY: DATE: REVISIONS: xxxx VA I L , E A G L E C O U N T Y CO L O R A D O HB 07.27.12 NO T F O R C O N S T R U C T I O N 1/16" = 1'-0" GROUND LEVEL = 2,436 sf31/16" = 1'-0" SUBGRADE CRAWL SPACE LESS THAN 5'-0" HEIGHT1 08.08.2012 HB 1/16" = 1'-0" BASEMENT LEVEL = 2,436 sf2 1/16" = 1'-0" MAIN LEVEL = 2,453 sf41/16" = 1'-0" UPPER LEVEL = 1,069 sf5 1/8" = 1'-0" ROOF PLAN7 09.10.2012 HB Floor Above SOLAR PANELS(N) 4:12 4:12 FLAT ROOF LINE OF WALL, TYP. LINE OF WALL, TYP. LINE OF ROOF, TYP. 2:12 3:122.6:12 SOLAR PANELS(N) SOLAR PANELS(S) 4:12 4:12 4:12 4:12 4:12 4:12 SOD ROOF FLAT ROOF FLAT ROOF SOD ROOF EDGE OF PARAPET,TYP. RDOS 2% 2% ROOF DECK (HEATED PAVERS) 20' FRONT SETBACK 20' FRONT SETBACK 15' RE A R S E T B A C K 243'-0"(8243'-0")T.O. Roof Sheathing. 241'-11-3/4"(8241'-11-3/4")T.O. Roof Sheathing. 241'-11-3/4"(8241'-11-3/4")T.O. Roof Sheathing. 243'-0"(8243'-0")T.O. Roof Sheathing. 238'-8-1/2"(8238'-8-1/2")T.O. Roof Sheathing.237'-9-1/4"(8237'-9-1/4")T.O. Roof Sheathing. 240'-4-7/8"(8240'-4-7/8")T.O. Roof Sheathing. 241'-0"(8241'-0")T.O. Roof Sheathing. 235'-6"(8235'-6")T.O. Roof Sheathing. 30 ' S T R E A M S E T B A C K 15' S I D E S E T B A C K 20' FRONT SETBACK 20' FRONT SETBACK 15' RE A R S E T B A C K 15 ' S I D E S E T B A C K 30' S T R E A M S E T B A C K 30 ' S T R E A M S E T B A C K 15' RE A R S E T B A C K 15 ' S I D E S E T B A C K PROPER T Y L I N E 30' S T R E A M S E T B A C K 30 ' S T R E A M S E T B A C K SOLAR PANELS(N) 4:12 4:12 FLAT ROOF LINE OF WALL, TYP. LINE OF WALL, TYP. LINE OF ROOF, TYP. 2:12 3:122.6:12 SOLAR PANELS(N) SOLAR PANELS(S) 4:12 4:12 4:12 4:12 4:12 4:12 SOD ROOF FLAT ROOF ROOF DECK (HEATED PAVERS) 243'-0"(8243'-0")T.O. Roof Sheathing. 241'-11-3/4"(8241'-11-3/4")T.O. Roof Sheathing. 241'-11-3/4"(8241'-11-3/4")T.O. Roof Sheathing. 243'-0"(8243'-0")T.O. Roof Sheathing. 240'-4-7/8"(8240'-4-7/8") T.O. Roof Sheathing. 238'-8-1/2"(8238'-8-1/2")T.O. Roof Sheathing.237'-9-1/4"(8237'-9-1/4")T.O. Roof Sheathing. 240'-4-7/8"(8240'-4-7/8") T.O. Roof Sheathing. 241'-0"(8241'-0")T.O. Roof Sheathing. 235'-6"(8235'-6")T.O. Roof Sheathing. 30 ' S T R E A M S E T B A C K 30 ' S T R E A M S E T B A C K 15' RE A R S E T B A C K 15 ' S I D E S E T B A C K PROJECT: 71 0 W E S T L I O N S H E A D C I R C L E - U N I T A V A I L . , C O L O R A D O 8 1 6 5 7 9 7 0 . 4 7 7 . 2 9 9 0 MI L L C R E E K C I R C L E RE S I D E N C E DRAWN BY: DATE: REVISIONS: xxxx VA I L , E A G L E C O U N T Y CO L O R A D O HB 02.27.12 NO T F O R C O N S T R U C T I O N 1 1/16" = 1'-0" PROPOSED ROOF PLAN/ HISTORICAL GRADE 05.29.2012 HB 07.19.2012 HB 08.01.2012 HB 08.08.2012 HB 09.10.2012 HB 2 1/16" = 1'-0" PROPOSED ROOF PLAN/ PROPOSED GRADE W/D Bench King Bookshelves Daybed MINI MASTER 211 218'-6" Fin Floor Elev. HIGH WINDOWS CORNER WINDOW WIC 213 Built-in Cab. Hanging Drawers/ shelves DRYING RACK Steam Shwr. high window W.C. TUB BATH 212 MEDICINE CABINETS TV(HIDDEN) DESK UP 17 R ' S @ 7 . 4 1 " 16 T ' S @ 1 ' - 0 " Art Glass Panel Bookshelves TV/ READING 210 CP CP CP ST STAIRS 208UPPER CABINETS French Balcony Planter Below CORNER WINDOW OPEN TO FOYER BELOW DN 16 R ' S @ 7 . 5 " 15 T ' S @ 1 ' - 0 " BALCONY 202 POWDER 209 Open Railing Lockset Door STST STCP CHANNEL GLASS CHANNEL GLASS ELEV. 201 Micro ref DINING 207 LIVING 206 Built-in Seating 76" X 84" Eating Ctr. 3-4 people PrepTrashStor. freez DWTrash DW Trash 36" Cereal/ Snack Appliance Gar. La corneauStor.Stor.Stor. Stor.Stor. French Balcony Stor. Built-in Seating BBQ AREA Built-in Wet Bar/ Ref/ DW/ and Buffet Serving HEARTH 205 KITCHEN 203 STONE VENEER (12-14) TV above LINE OF ANGLED WALL ABOVE 500 Series 54"ref.ice wok smoker FIREPIT FOUNTAIN 8218'-6" Patio Elev. TV Cubbies TV Ref. 218'-6" Fin Floor Elev. GYM 215 HIGH WINDOWS MIRRORED WALL Shwr. ROBE HOOKS BATH 214 French Balcony WINDOW @ POOL FLOOR STCP DN GLASS OVERFLOW EDGE OF LAP POOL OVERFLOW @ WEST SIDE ONLY SPA Planter Below 11 ' - 7 78" 12'-334" 6' - 8 1 2" 6'-41 4" 15 ' - 7 " 14'-81 4" 11'-612" 10 ' - 2 58" 6' - 2 " 11 ' - 2 " 17'-05 8" 7'-1112" 14 ' - 4 12" 4' - 4 14" 8'-534" 4'-3 34 "4' - 1 0 " 13'-138"9' - 2 18" 10 ' - 1 1 78" 13'-15 8" 15 ' - 6 5 8" 6' - 1 0 " 9'-11" 13'-113 4" 11 ' - 7 12" 10'-034"3' - 7 " 2' - 6 " 3' - 8 " 3' - 4 " 18'-01 8" 30 ' S T R E A M S E T B A C K 30 ' S T R E A M S E T B A C K 15 ' S I D E S E T B A C K 20' FRONT SETBACK 20' FRONT SETBACK 10'-0" 60'-0" 218'-6" Fin Floor Elev. 218'-6" Fin Floor Elev. 218'-6" Fin Floor Elev. 228'-4" Bot. of Clg. Structure 227'-11-7/8" Bot. of Clg. Structure 218'-6" Fin Floor Elev. 227'-11-7/8" Bot. of Clg. Structure 234'-1-7/8" Bot. of Clg. Structure(Gable Peak) 228'-6" Bot. of Clg. Structure 15' R E A R S E T B A C K 15 ' S I D E S E T B A C K PRO P E R T Y L I N E Gas FP PROJECT: 71 0 W E S T L I O N S H E A D C I R C L E - U N I T A V A I L . , C O L O R A D O 8 1 6 5 7 9 7 0 . 4 7 7 . 2 9 9 0 MI L L C R E E K C I R C L E RE S I D E N C E DRAWN BY: DATE: REVISIONS: xxxx VA I L , E A G L E C O U N T Y CO L O R A D O HB 02.27.12 NO T F O R C O N S T R U C T I O N 1 1/4" = 1'-0" PROPOSED MAIN FLOOR PLAN 05.29.2012 HB 07.19.2012 HB 08.01.2012 LF 08.08.2012 HB 09.10.2012 HB W/D King TUB Bookshelves WIC 306 Hanging 229'-0" Fin Floor Elev. HIGH WINDOWS Ref.DW Hanging Steam Shwr. W.C. W.C./ BIDET DN 17 R ' S @ 7 . 4 1 " 16 T ' S @ 1 ' - 0 " OPEN TO STAIRS BELOW ELEV. 302COFFEE BAR 304 READING 305 HALL 303 MASTER BATH 307 MASTER BEDROOM 308 GORE VIEW GAS "RIBBON" FP 60" T&C HIGH WINDOWS DOOR W/ FR. BALCONY (STREAM) HWTILE HW HW HWHW 229'-0" Fin Floor Elev. 229'-0" Fin Floor Elev. 223'-3" Fin Floor Elev. STAIRS 301 SOD ROOF Lockset Door 6" medicine cabinet ROOF DECK WITH HEATED PAVERS WINDOWS ABOVE CHANNEL GLASS CORNER WINDOW CORNER WINDOW 229'-0" Fin Floor Elev. Mirror niche Bench 7'-0" dia. shaft CORNER WINDOW SOD ROOF 14'-814" 16 ' - 7 14" 18'-534" 9' - 8 34" 11'-11" 10'-9" 10 ' - 2 34" 3'-2"3' - 2 " 6'-114" 5'-834" 5' - 1 1 4" 6' - 1 0 58" 240'-6-3/8" Bot. of Clg. Structure(Gable Peak) 241'-10-3/4" Bot. of Clg. Struct. (Gable Peak) 229'-0" Fin Floor Elev. 241'-10-3/4" Bot. of Clg. Struct. (Gable Peak) 15 ' S I D E S E T B A C K 20' FRONT SETBACK 20' FRONT SETBACK 15' R E A R S E T B A C K 15 ' S I D E S E T B A C K 30 ' S T R E A M S E T B A C K PROJECT: 71 0 W E S T L I O N S H E A D C I R C L E - U N I T A V A I L . , C O L O R A D O 8 1 6 5 7 9 7 0 . 4 7 7 . 2 9 9 0 MI L L C R E E K C I R C L E RE S I D E N C E DRAWN BY: DATE: REVISIONS: xxxx VA I L , E A G L E C O U N T Y CO L O R A D O HB 02.27.12 NO T F O R C O N S T R U C T I O N 1 1/4" = 1'-0" PROPOSED UPPER FLOOR PLAN 05.29.2012 HB 07.19.2012 HB 08.01.2012 LF 08.08.2012 HB 09.10.2012 HB SOLAR PANELS(S) SOLAR PANELS(N) 4:12 4:12 METAL SNOW-GUARD LINE OF WALL, TYP. LINE OF RIDGE RDOS 2% 2% ROOF CURB FLAT ROOF METAL SNOW-GUARD RDOS 2% 2%2% LINE OF WALL, TYP. LINE OF WALL, TYP. LINE OF ROOF, TYP. 2:12 INTERNAL SCUPPER W/ HEAT TAPE & DOWNSPOUT ROOF CURB METAL SNOW-GUARD SOLAR PANELS(N) 3:122.6:12 METAL SNOW-GUARD SOLAR PANELS(N) SOLAR PANELS(S) SOLAR PANELS(S) 4:12 4:12 4:12 4:12 4:12 4:12 METAL SNO W - G U A R D METAL SNOW-GUARD METAL SNOW-GUARDMETAL SNOW-GUARD METAL SNOW-GUARD SOD ROOF FLAT ROOF FLAT ROOF SOD ROOF EDGE OF PARAPET, TYP. RDOS 2% 2% ROOF DECK (HEATED PAVERS) 15 ' S I D E S E T B A C K 20' FRONT SETBACK 20' FRONT SETBACK 2' - 9 18" 1'- 6 1 2" 2'-6"2' - 6 " 3'-21 2" 2'-6" 2' - 6 " 6" 6" 3'-115 8" 1'-103 4"2' - 1 1 14" 1' - 1 1 8" 10 1 4" 2'-6" 1'- 0 " 2'-6" 2' - 0 " 2'-6" 2' - 0 " 2'-6" 1'-6"1' - 0 " 1' - 0 " 2'-6" 2' - 0 " 1'-81 8" 15' R E A R S E T B A C K 1 5 ' S I D E S E T B A C K 30 ' S T R E A M S E T B A C K PROJECT: 71 0 W E S T L I O N S H E A D C I R C L E - U N I T A V A I L . , C O L O R A D O 8 1 6 5 7 9 7 0 . 4 7 7 . 2 9 9 0 MI L L C R E E K C I R C L E RE S I D E N C E DRAWN BY: DATE: REVISIONS: xxxx VA I L , E A G L E C O U N T Y CO L O R A D O HB 02.27.12 NO T F O R C O N S T R U C T I O N 1 1/4" = 1'-0" PROPOSED ROOF PLAN 05.29.2012 HB 07.19.2012 HB 08.01.2012 HB 08.08.2012 HB 09.10.2012 HB T.O. TOPPING 229'-0" (8229'-0") T.O. TOPPING 218'-6" (8218'-6") T.O. TOPPING 204'-0" (8204'-0") T.O. SHEATHING(SLOPED ROOF) 143'-0" (8243'-0") M01 M05 M05 M07 M10 M02 M03M08 M03 M04 M04 M06 LINE OF GYM/ SPORTS STORAGE POOL BEYONDPATIO BEYOND M03 T.O. TOPPING 194'-6" (8194'-6") CRAWL LESS THAN 5'-0" HT. 5'- 0 " CRAWL LESS THAN 5'-0" HT. 5'- 0 " CRAWL LESS THAN 5'-0" HT. 5'- 0 " T.O. TOPPING 206'-6" (8206'-6") T.O. TOPPING 218'-6" (8218'-6") T.O. TOPPING 229'-0" (8229'-0") M03 M03 M01 M01 M08 M02 M06 M04 T.O. TOPPING 204'-0" (8204'-0") T.O. TOPPING 208'-6" (8208'-6") T.O. SHEATHING(SLOPED) 241'-11-3/4" (8241'-11-3/4") HISTORICAL GRADE 210'-0" (8210'-0") 33 ' - 0 " 33 ' - 0 " 32 ' - 1 0 1 8" 26 ' - 4 " 30 ' - 1 0 1 2" M03 M01 T.O. SHEATHING (SLOPED) 243'-0" (8243'-0") T.O. SHEATHING-PARAPET 231'-10" (8231'-10") PATIO BEYOND POOL BEYOND PLANTER- SEE L1 M01 12 ' - 1 0 34" PROJECT: 71 0 W E S T L I O N S H E A D C I R C L E - U N I T A V A I L . , C O L O R A D O 8 1 6 5 7 9 7 0 . 4 7 7 . 2 9 9 0 MI L L C R E E K C I R C L E RE S I D E N C E / L O T # 3 DRAWN BY: DATE: REVISIONS: xxxx VA I L , E A G L E C O U N T Y CO L O R A D O HB 07.27.12 NO T F O R C O N S T R U C T I O N 05.29.2012 HB 06.06.2012 HB 1 1/4" = 1'-0" NORTH ELEVATION 2 1/4" = 1'-0" WEST ELEVATION 08.08.2012 HB 08.15.2012 HB 08.20.2012 HB T.O. TOPPING 218'-6" (8218'-6") T.O. TOPPING 208'-6"(8208'-6") T.O. TOPPING 194-6"(8194'-6") TO LIVING/ DINING/ KITCHEN TO GUEST BEDROOMS CRAWL/ LESS THAN 5'-0" HT. TO GAME/ THEATRE ENTRY FOYER 101 WINE 012 1' - 3 78"MECH. PLENUM OUTDOOR DINING SOD ROOF OPEN RAILING 11 ' - 0 " 8'- 1 1 78" 9' - 1 0 " 19 ' - 1 0 " 9' - 0 " 5' - 0 " HEATERS TRELLIS HEATERS BBQ BEYOND WEST ELEV./HEATERS PRIVACY PANEL BEYOND TRELLIS KITCHEN 203 INDOOR DINING METAL SHROUD KERFED CUT STONE GAS LOG SET FRENCH BALCONY HEARTH 205 GUESTBEDROOM #1 105 GUESTWET BAR 103 HEATERS GUEST PATIO GAME 016 THEATRE 017 BATH BEYOND LAUNDRY BEYOND 9'- 0 " 8'- 1 78" 12 ' - 4 78" 7' - 6 " 1'- 1 0 " 9'- 0 " 9'- 0 18" 3'- 0 " MECH. PLENUM CRAWL./ LESS THAN 5'-0" HT. 5'- 0 " T.O. TOPPING 229'-0"(8229'-0") T.O. TOPPING 218'-6" (8218'-6") MECH. PLENUM HEARTH 205LIVING 206 DINING BEYOND FP HALLWAY BEYOND CLEAN ROOM15 ' - 7 78" 9'- 6 " 11 ' - 4 14" PROJECT: 71 0 W E S T L I O N S H E A D C I R C L E - U N I T A V A I L . , C O L O R A D O 8 1 6 5 7 9 7 0 . 4 7 7 . 2 9 9 0 MI L L C R E E K C I R C L E RE S I D E N C E / L O T # 3 DRAWN BY: DATE: REVISIONS: xxxx VA I L , E A G L E C O U N T Y CO L O R A D O HB 07.27.12 NO T F O R C O N S T R U C T I O N 05.29.2012 HB 06.06.2012 HB 1 1/4" = 1'-0" WEST ELEVATION- KITCHEN 08.20.2012 HB 3 1/4" = 1'-0" SECTION @ KITCHEN/ THEATRE FACING NORTH 2 1/4" = 1'-0" SECTION @ LIVING FACING WEST 760.744.5240 | fxl.com LED Wall Lights logo (2-color PMS) ®FX: GOE 158-1-5 Luminaire: PMS 408 C Learn more about FX Luminaire wall lights. Visit: fxl.com/products/products NumBer oF LeDs:1 HaLogeN LumeN output equivaLeNt:10 Watt useFuL LeD LiFe (L70):50,000 hrs avg iNput voLtage:10 to 15V va totaL: (use this number to size the transformer)2.4 Watts useD:2.0 LumeNs per Watt (eFFicacy)37 max LumeNs:77 cct (ra)81.6 LF: Wall Light The LouverFenêtre is our LED under-the-cap hard- scape wall light. It can easily be fitted between a block wall and capstone for a neat, clean installation. Due to its modular bracket design, the LF can even be installed under railings and existing construction. 3. 6 " 9 . 2 c m 6.7"/17 cm .9 " 2. 2 c m ORDERING INFORMATION LED 760.744.5240 | fxl.com4/12 logo (2-color PMS) ®FX: GOE 158-1-5Luminaire: PMS 408 C pHotometrics: Vertical Spread: 103.0º LF 1LED ILLUMINANCE AT A DISTANCE 4.2 8.3 12.5 16.7 20.8 25.0 Center Beam FC Beam Width Horizontal Spread: 52.9º 2.94 fc 0.73 fc 0.33 fc 0.18 fc 0.12 fc 0.08 fc 10.5 20.9 31.4 41.9 52.4 62.8 4.1 8.3 12.4 16.6 20.7 24.9 MetaLS aB = Antique Bronze* (On Copper) aB = Antique Bronze* (On Brass) at = Antique Tumbled*(On Copper) at = Antique Tumbled* (On Brass) cU = Copper Np = Nickel Plate BS = Natural Brass SS = Stainless Steel powdercoat wG = White Gloss Fw = Flat White aL = Almond BZ = Bronze Metallic dG = Desert Granite wI = Weathered Iron VF = Verde Speckle SB = Sedona Brown FB = Flat Black * May require longer lead time exampLe: LF-1LeD-ss = LF - 1 LeD - stainless steel Finish Factory iNstaLLeD optioNs: Order 1 + 2 + 3 Fixture coDe Lamp coDe FiNisH optioNs 1 LF 2 1 Led (50,000 avg. life hours)3 XX (see options to right) LF: Wall Light For information on ZD technology please refer to the Luxor page in the Lighting Control section. The LF includes a 1LED board and your choice of faceplate finish and 10 ft. lead wire. All LF wall lights come standard with amber, and frosted filters Beam angle is calculated using LM-79 method for SSL Luminaires: "Beam angle is defined as two times the vertical angle at which the intensity is 50% of the maximum". 760.744.5240 | fxl.com logo (2-color PMS) ®FX: GOE 158-1-5 Luminaire: PMS 408 C Learn more about FX Luminaire path lights. Visit: fxl.com/products cb: Path Light LED Path Lights The CB is a soft, efficient, and safe path light that can be used for pathways of all shapes, sizes, and locations. It's sleek hat shape gives it a more contemporary look that can accentuate landscapes that are trying to acheive a modern facade. Number of LeDS:1 3 HaLogeN LumeN output equivaLeNt:10 Watt 20 Watt uSefuL LeD Life (L70):50,000 hrs avg 50,000 hrs avg iNput voLtage:10 to 15V 10 to 15V va totaL: (use this number to size the transformer)2.4 4.5 WattS uSeD:2.0 4.2 LumeNS per Watt (efficacy)19.4 25 max LumeNS:39 103 cct (ra)86 66.6 15 . 5 " / 3 9 . 4 c m 7.2"/18.29 cm ORDERING INFORMATION LED 760.744.5240 | fxl.com4/12 logo (2-color PMS) ®FX: GOE 158-1-5Luminaire: PMS 408 C pHotometricS: Distance in units of mount height 20 fc 2.5 fc 0.2 fc Mount height: 110 fc 1 fc 0.1 fc Total LLF: 1 5 fc 0.5 fc 50% Max Candela 5 4 3 2 1 0 1 2 3 4 5 4 3 2 1 0 1 2 3 4 5 CB 3LED ISOFOOTCANDLE PLOT Distance in units of mount height 20 fc 2.5 fc 0.2 fc Mount height: 110 fc 1 fc 0.1 fc Total LLF: 1 5 fc 0.5 fc 50% Max Candela 5 4 3 2 1 0 1 2 3 4 5 4 3 2 1 0 1 2 3 4 5 CB 1LED ISOFOOTCANDLE PLOT exampLe: cb-3LeD-12r-Dg = cb - 3 LeD board - 12" riser - Desert granite finish 753900 = Super Slot Spike cb: Path Light MetaLs aB = Antique Bronze* (On Copper) at = Antique Tumbled*(On Copper) CU = Copper NP = Nickel Plate PowderCoat wG = White Gloss Fw = Flat White aL = Almond BZ = Bronze Metallic dG = Desert Granite wI = Weathered Iron VF = Verde Speckle sB = Sedona Brown FB = Flat Black factory iNStaLLeD optioNS: Order 1 + 2 + 3 + 4 fixture coDe Lamp coDe riSer optioNS fiNiSH optioNS 1 CB 2 1 Led (50,000 avg. life hours)3 8r (8" Riser)4 XX 3 Led (50,000 avg. life hours)12r (12" Riser) (see options to right) 18r (18" Riser) 24r (24" Riser) 36r (36" Riser) The CB includes your choice of 1 or 3LED board, riser size, finish, 5 ft. lead wire and a Long Slot Spike. For information on ZD technology please refer to the Luxor page in the Lighting Control section. * May require longer lead time Note: Only the copper portions of the Pathlights are powdercoated. The brass pieces remain natural. ** Denotes powdercoat finish All CB path lights come standard with amber, green, blue and frosted filters fieLD iNStaLLeD optioNS: Order Individually mouNtiNg optioNS Long slot spike (250015840000) 2.5" x 10" Included 4 super slot spike (753900) 2" x 10" superJ-Box (SJ-XX**) 2.5" x 12" Post Mount (PM-XX**) 2.5" x 13"Long Slot Spike Super Slot Spike Super J-box XX** post mount XX** Beam angle is calculated using LM-79 method for SSL Luminaires: "Beam angle is defined as two times the vertical angle at which the intensity is 50% of the maximum". 760.744.5240 | fxl.com logo (2-color PMS) ®FX: GOE 158-1-5 Luminaire: PMS 408 C lm-20 Perfection Every Time With the LevelX feature built-in, the designer can be in complete comfort that the fixture will be installed on a perfectly level visual line. With the durable, sturdy materials, the user can have confidence that the fixture can last for years on end. CommerCial Quality, residential PriCe Point The LM is engineered to bring light to areas such as walkways, stairways and decks as well as to other foot traffic hazards that don't have an adjacent planter area for path lighting or trees and trellis from which to down light. Incorporated into the design is the LevelX feature. The LevelX assures the lighting installer that the faceplates of these permanently mounted fixtures will remain perfectly level upon completion of the installation. Many step and wall lights on the market today are designed so that if the mounting box is installed out-of-level, the face- plate, once installed, will also be noticeably out-of-level. Some of the features of the LM include: Sleeve permanently mounted in concrete or wood wall combined with multiple threaded knockouts, easy-to- remove box for unforeseen future problems, which prevents having to chip away at the wall for repairs. 9"/22.86 cm 3. 5 " / 8 . 8 9 c m 3.5" 8.89 c m ORDERING INFORMATION 760.744.5240 | fxl.com4/12 logo (2-color PMS) ®FX: GOE 158-1-5Luminaire: PMS 408 C MEtaLs CU = Copper NP = Nickel Plate PowDErCoat wG = White Gloss Fw = Flat White aL = Almond BZ = Bronze Metallic DG = Desert Granite wI = Weathered Iron VF = Verde Speckle sB = Sedona Brown FB = Flat Black The LM includes two 10 watt Xenon or Halogen lamps, your choice of faceplate finish and a mounting sleeve. EXAMPLE: LM-20-SB = LM - 20 W Xenon - Bronze Metallic Finish FACTORY INSTALLED OPTIONS: Order 1 + 2 + 3 FIXTURE CODE LAMP CODE FINISH OPTIONS 1 LM 2 20 (10,000 Hrs Xenon)3 XX (see options to right) 20H (2,000 Hrs Halogen) LM: Wall Light MOUNTING FEATURES AND DIMENSIONS: level level Perfection Every Time The LevelX system allows the composite sleeve to be up to ⅜" out of level, in either direction, while still allowing the faceplate to be laser level. The secret: The trim attaches to the adjustable reflector assembly – not the composite sleeve or body. Heavy foam gasket keeps light spill to a minimum. 2. 6 2 5 " 8.37 5 " 4.0" Sleeve 9.0" 3.5 " Faceplate 8.12 5 " 2.375" Box 2. 3 7 5 "