HomeMy WebLinkAboutDRB120464 Basingdale East Elevation DRBHOA
APPROVAL
9/24/12
2801
Basingdale
Blvd
#8
Vail,
CO
81657
1
9/24/12
2801
Basingdale
Blvd
#8
Vail,
CO
81657
2
Revision
NarraCve
The
new
window
will
match
the
exisCng
windows
that
have
been
approved
for
replacement
in
the
original
submission.
• The
new
window
will
be
42”
off
the
floor
• The
full
window
unit
rough
opening
is
96”
x
54”
• The
components
of
the
window
unit
is
a
48”
x
54”
fixed
picture
window
with
a
24”
x
48”
casement
window
on
either
side
of
it.
• The
windows
are
white
vinyl
to
match
all
other
windows
in
the
complex
including
the
replacement
windows
previously
approved
• The
new
window
will
be
trimmed
with
dark
grey
brick
molding
to
match
the
exisCng
and
the
outer
trim
will
match
the
exisCng
outer
trim
in
both
size
and
color
• The
leW
side
of
the
new
window
unit
will
align
with
the
leW
side
of
the
window
below
and
each
verCcal
line
in
the
windows
(above
and
below)
will
line
up
with
one
another
• The
new
window
unit
is
designed
to
be
2x
the
width
of
the
window
below
9/24/12
2801
Basingdale
Blvd
#8
Vail,
CO
81657
3
ElevaCon
of
New
Window
on
East
Wall
• Overall
rough
opening
is
96’
x
54
and
the
window
elevaCon
is
42”
above
the
floor
• LeW
side
of
the
window
lines
up
with
the
leW
side
of
the
window
below.
The
windows
are
white
vinyl
like
all
other
windows
in
the
unit
and
they
will
be
trimmed
and
painted
the
same
colors
as
all
other
windows
in
the
complex
Key
InformaCon
Window
Schedule
• Rough
Opening
96”
x
54”
Frame
Size:
95
1/2”
x
53
½”
• Jeld-‐Wen
Premium
Vinyl
Awning/Picture
window
combinaCon
window
unit
with
even
sight
line
• White
Ext
/White
Int
• Low
–E
366
Clear
High
AlCtude
• U
Factor
0:33,
SHGC:
0.22
VT:
0:51,
ER:
9.00
Town
of
Vail
Structural
Design
Criteria
(QuesCons
call
MarCn
Haeberle
…
another
Kansas
guy
…
• Roof
Snow
Load:
80
PSF
for
roofs
4:12
or
greater
slope
Seismic:
Short
period
spectral
response:
Ss
=035.0
• 100
PSF
for
decks
and
roofs
less
than
4:12
Long
period
spectral
response:
S1=
008.1
• Wind
Speed:
90
mph
(3
second
gust),
exposure
B
Site
Class:
determined
by
soils
report
• Frost
Depth:
48”
Adopted
Codes
&
Standards:
• 2009
InternaConal
ResidenCal
Code
• 2009
InternaConal
Plumbing
Code
• 2009
InternaConal
Mechanical
Code
• 2009
InternaConal
Fuel
Gas
Code
• 2009
InternaConal
Fire
Code
• 2009
InternaConal
Energy
ConservaCon
Code
• 2008
NaConal
Electrical
Code
• 2003
ICC/ANSI
A117.1
(Accessibility
Standards)
• 2009
Amendments
located
in
Ordinance
No.
18,
Series
2009
9/24/12
2801
Basingdale
Blvd
#8
Vail,
CO
81657
4