Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
F12-0060 Attic 1 Calc - signed
FIRE - Fire Sprinkler Hydraulics Calculation Program Elite Software Development, Inc. A & A Fire Protection Lion Square Lodge-East Building-Attic 1 Glenwood Springs, CO 81611 Page 2 General Project Data Report General Data Project Title:Lion Square Lodge-East Building- Attic 1 Project File Name:Lion Square Attic 1..fiw Designed By:Bojar Voda Date:9/17/2012 Code Reference:NFPA 13, Light Hazard Approving Agency:VFPD Client Name:J.L. Viele Construction Phone:(970) 476-3082 Address:1000 South Frontage Road West Suite 202 City, State Zip Code:Vail, Colorado 81657 Company Name:Sprinklers R Us, Inc.Representative:Bojar Voda Company Address:0035 Apache Trail City And State:Carbondale, CO 81623 Phone:(970) 963-8752 Building Name:Lion Square Lodge, East BuildingBuilding Owner:Lion Square Lodge Contact at Building:Mark Phone at Building: Address Of Building:Lionshead Place City, State Zip Code:Vail, Colorado 81657 Project Data Description Of Hazard:Light Hazard Sprinkler System Type:Dry Design Area Of Water Application:2567ft²Maximum Area Per Sprinkler:100ft² Default Sprinkler K-Factor:2.80KDefault Pipe Material:SCHED 10 WET STEEL Inside Hose Stream Allowance:0.00gpmOutside Hose Stream Allowance:100.00gpm In Rack Sprinkler Allowance:0.00gpm Sprinkler Specifications Make:TYCO Model:FRB Size:1/2"Temperature Rating:155F NONE Water Supply Test Data Source Of Information: Test Hydrant ID:Date Of Test: Hydrant Elevation:0ftStatic Pressure:150.00psi Test Flow Rate:500.00gpmTest Residual Pressure:140.00psi Calculated System Flow Rate:418.07gpmCalculated Inflow Residual Pressure:122.14psi Available Residual Pressure At System Flow:142.82psi Calculation Project Data Calculation Mode:Demand HMD Minimum Residual Pressure:7.00psiMinimum Desired Flow Density:0.10gpm/ft² Maximum Water Velocity:20.00ft/sMaximum Frictional Loss / 100 feet:20.00psi Number Of Active Nodes:80 Number Of Active Pipes:80 Number Of Inactive Pipes:0 Number Of Active Sprinklers:42 Number Of Inactive Sprinklers:0 I:\GVWF\12800\07\Lion Square Attic 1..fiw Wednesday, September 19, 2012, 4:06 PM FIRE - Fire Sprinkler Hydraulics Calculation Program Elite Software Development, Inc. A & A Fire Protection Lion Square Lodge-East Building-Attic 1 Glenwood Springs, CO 81611 Page 3 Fire Sprinkler Output Data Overall Pipe Output Data Beg. End. Node Nodal KFactor (K) Elevation (feet) Spk/Hose Discharge (gpm) Residual Pressure (psi) Nom. Dia. Inside Dia. C-Value q (gpm) Q (gpm) Velocity (fps) F. L./ft (psi/ft) Fittings Type-Grp Pipe-Len. Fit-Len. Tot-Len. (ft) PF-(psi) PE-(psi) PT-(psi) 2740.008.000.00105.804.000.000.054902.830.155 200.000.000.00109.424.260418.07-----0.003.464 SCHD 10 STEEL, DRY 1009.4102.833.619 200.000.000.00109.424.000.000.054903.500.582 210.007.000.00106.974.260418.07E7.10-3.031 SCHD 10 STEEL, DRY 1009.41010.60-2.449 21 Backflo Prev 7.00 106.97 418.07 225.00 psi7.00 111.98 220.007.000.00111.984.000.000.054907.081.948 230.008.000.00113.504.260418.072ET28.40-0.433 SCHD 10 STEEL, DRY 1009.41035.481.515 230.008.000.00113.504.000.000.0381717.422.970 240.003.000.00118.633.935418.074E60.402.165 TYPE M COPPER TUBE 15011.03077.825.135 240.003.000.00118.634.000.000.0381745.003.507 250.003.000.00122.143.935418.07ETG46.900.000 TYPE M COPPER TUBE 15011.03091.903.507 2012.8057.009.2210.842.000.000.0463010.080.629 2020.0057.000.0010.212.15763.57E3.500.000 SCHD 10 STEEL, DRY 1005.58013.580.629 2020.0057.000.0010.211.007.810.025766.830.266 2032.8062.007.817.781.0977.81T3.502.165 SCHD 10 STEEL, DRY 1002.65010.332.431 2020.0057.000.0010.212.008.890.036333.670.133 2042.8057.008.8910.082.15755.76-----0.000.000 SCHD 10 STEEL, DRY 1004.9003.670.133 2042.8057.008.8910.082.008.710.0263412.170.413 2052.8057.008.719.672.15746.87E3.500.000 SCHD 10 STEEL, DRY 1004.12015.670.413 2052.8057.008.719.672.000.000.018016.670.120 2060.0057.000.009.552.15738.16-----0.000.000 SCHD 10 STEEL, DRY 1003.3506.670.120 2060.0057.000.009.551.007.450.029356.830.303 2072.8062.007.457.081.0497.45T3.502.165 SCHED 40 STEEL,DRY 1002.77010.332.468 I:\GVWF\12800\07\Lion Square Attic 1..fiw Wednesday, September 19, 2012, 4:06 PM FIRE - Fire Sprinkler Hydraulics Calculation Program Elite Software Development, Inc. A & A Fire Protection Lion Square Lodge-East Building-Attic 1 Glenwood Springs, CO 81611 Page 4 Fire Sprinkler Output Data Overall Pipe Output Data (cont'd) Beg. End. Node Nodal KFactor (K) Elevation (feet) Spk/Hose Discharge (gpm) Residual Pressure (psi) Nom. Dia. Inside Dia. C-Value q (gpm) Q (gpm) Velocity (fps) F. L./ft (psi/ft) Fittings Type-Grp Pipe-Len. Fit-Len. Tot-Len. (ft) PF-(psi) PE-(psi) PT-(psi) 2060.0057.000.009.552.008.640.012051.830.022 2082.8057.008.649.532.15730.71-----0.000.000 SCHD 10 STEEL, DRY 1002.7001.830.022 2082.8057.008.649.532.008.620.006548.580.056 2092.8057.008.629.472.15722.07-----0.000.000 SCHD 10 STEEL, DRY 1001.9408.580.056 2092.8057.008.629.472.000.000.002621.830.005 2100.0057.000.009.472.15713.46-----0.000.000 SCHD 10 STEEL, DRY 1001.1801.830.005 2100.0057.000.009.471.007.410.029046.830.300 2112.8062.007.417.001.0497.41T3.502.165 SCHED 40 STEEL,DRY 1002.75010.332.465 2100.0057.000.009.472.006.050.000606.670.004 2122.8057.008.619.462.1576.05-----0.000.000 SCHD 10 STEEL, DRY 1000.5306.670.004 2122.8057.008.619.462.002.560.0001211.920.002 2132.8057.008.619.462.1572.56E3.500.000 SCHD 10 STEEL, DRY 1000.23015.420.002 2132.8057.008.619.462.008.610.001864.000.007 2140.0057.000.009.472.15711.18-----0.000.000 SCHD 10 STEEL, DRY 1000.9804.000.007 2140.0057.000.009.471.007.440.023556.830.243 2152.8062.007.447.061.0977.44T3.502.165 SCHD 10 STEEL, DRY 1002.53010.332.408 2140.0057.000.009.472.000.000.004778.000.055 2162.8057.008.649.532.15718.62E3.500.000 SCHD 10 STEEL, DRY 1001.63011.500.055 2162.8057.008.649.532.008.640.009677.250.070 2172.8057.008.679.602.15727.26-----0.000.000 SCHD 10 STEEL, DRY 1002.3907.250.070 2172.8057.008.679.602.008.670.016117.250.117 2182.8057.008.739.712.15735.93-----0.000.000 SCHD 10 STEEL, DRY 1003.1507.250.117 2182.8057.008.739.712.008.730.024098.000.277 2190.0057.000.009.992.15744.66E3.500.000 SCHD 10 STEEL, DRY 1003.92011.500.277 I:\GVWF\12800\07\Lion Square Attic 1..fiw Wednesday, September 19, 2012, 4:06 PM FIRE - Fire Sprinkler Hydraulics Calculation Program Elite Software Development, Inc. A & A Fire Protection Lion Square Lodge-East Building-Attic 1 Glenwood Springs, CO 81611 Page 5 Fire Sprinkler Output Data Overall Pipe Output Data (cont'd) Beg. End. Node Nodal KFactor (K) Elevation (feet) Spk/Hose Discharge (gpm) Residual Pressure (psi) Nom. Dia. Inside Dia. C-Value q (gpm) Q (gpm) Velocity (fps) F. L./ft (psi/ft) Fittings Type-Grp Pipe-Len. Fit-Len. Tot-Len. (ft) PF-(psi) PE-(psi) PT-(psi) 2190.0057.000.009.991.007.670.030976.830.320 2202.8062.007.677.501.0497.67T3.502.165 SCHED 40 STEEL,DRY 1002.85010.332.485 2190.0057.000.009.992.000.000.032304.000.129 2212.8057.008.9110.122.15752.33-----0.000.000 SCHD 10 STEEL, DRY 1004.5904.000.129 2212.8057.008.9110.122.008.910.0432011.830.662 2222.8057.009.1910.782.15761.24E3.500.000 SCHD 10 STEEL, DRY 1005.38015.330.662 2222.8057.009.1910.782.009.190.055966.670.373 2230.0057.000.0011.152.15770.43-----0.000.000 SCHD 10 STEEL, DRY 1006.1806.670.373 2230.0057.000.0011.151.008.220.035236.830.364 2242.8062.008.228.631.0498.22T3.502.165 SCHED 40 STEEL,DRY 1003.05010.332.529 2230.0057.000.0011.152.000.000.068651.830.126 2252.8057.009.4011.282.15778.65-----0.000.000 SCHD 10 STEEL, DRY 1006.9101.830.126 2252.8057.009.4011.282.009.400.084608.580.726 2262.8057.009.7012.012.15788.06-----0.000.000 SCHD 10 STEEL, DRY 1007.7308.580.726 2262.8057.009.7012.012.009.700.102651.830.188 2270.0057.000.0012.192.15797.76-----0.000.000 SCHD 10 STEEL, DRY 1008.5801.830.188 2270.0057.000.0012.191.008.690.038996.830.403 2282.8062.008.699.631.0498.69T3.502.165 SCHED 40 STEEL,DRY 1003.22010.332.568 2270.0057.000.0012.192.000.000.120166.670.801 2292.8057.0010.0912.992.157106.45-----0.000.000 SCHD 10 STEEL, DRY 1009.3506.670.801 2292.8057.0010.0912.992.0010.090.1420912.172.226 2302.8057.0010.9215.222.157116.54E3.500.000 SCHD 10 STEEL, DRY 10010.23015.672.226 2302.8057.0010.9215.222.0010.920.167713.670.615 2310.0057.000.0015.842.157127.46-----0.000.000 SCHD 10 STEEL, DRY 10011.1903.670.615 I:\GVWF\12800\07\Lion Square Attic 1..fiw Wednesday, September 19, 2012, 4:06 PM FIRE - Fire Sprinkler Hydraulics Calculation Program Elite Software Development, Inc. A & A Fire Protection Lion Square Lodge-East Building-Attic 1 Glenwood Springs, CO 81611 Page 6 Fire Sprinkler Output Data Overall Pipe Output Data (cont'd) Beg. End. Node Nodal KFactor (K) Elevation (feet) Spk/Hose Discharge (gpm) Residual Pressure (psi) Nom. Dia. Inside Dia. C-Value q (gpm) Q (gpm) Velocity (fps) F. L./ft (psi/ft) Fittings Type-Grp Pipe-Len. Fit-Len. Tot-Len. (ft) PF-(psi) PE-(psi) PT-(psi) 2310.0057.000.0015.841.0010.150.051996.830.537 2322.8062.0010.1513.131.04910.15T3.502.165 SCHED 40 STEEL,DRY 1003.77010.332.702 2310.0057.000.0015.842.000.000.1932410.082.624 2330.0057.000.0018.462.157137.61E3.500.000 SCHD 10 STEEL, DRY 10012.08013.582.624 2330.0057.000.0018.462.000.000.1932411.333.542 2340.0057.000.0022.002.157137.612E7.000.000 SCHD 10 STEEL, DRY 10012.08018.333.542 2340.0057.000.0022.002.000.000.1932410.171.965 2352.8057.0013.7123.972.157137.61-----0.000.000 SCHD 10 STEEL, DRY 10012.08010.171.965 2352.8057.0013.7123.972.0013.710.230358.832.034 2360.0057.000.0026.002.157151.32-----0.000.000 SCHD 10 STEEL, DRY 10013.2908.832.034 2360.0057.000.0026.001.000.000.279017.002.930 2370.0062.000.0020.911.04925.16T3.502.165 SCHED 40 STEEL,DRY 1009.34010.505.095 2370.0062.000.0020.911.0012.670.078441.830.418 2382.8062.0012.6720.491.04912.67T3.500.000 SCHED 40 STEEL,DRY 1004.7105.330.418 2370.0062.000.0020.911.0012.490.061406.580.576 2392.8063.0012.4919.901.09712.492E2.800.433 SCHD 10 STEEL, DRY 1004.2409.381.009 2360.0057.000.0026.002.500.000.115521.330.154 2402.8057.0014.3226.162.635176.48-----0.000.000 SCHD 10 STEEL, DRY 10010.3801.330.154 2402.8057.0014.3226.162.5014.320.133462.501.455 2410.0057.000.0027.612.635190.80T8.400.000 SCHD 10 STEEL, DRY 10011.23010.901.455 2410.0057.000.0027.612.500.000.184443.832.256 2420.0057.000.0025.352.635227.27T8.400.000 SCHD 10 STEEL, DRY 10013.37012.232.256 2420.0057.000.0025.351.000.000.271067.002.846 2430.0062.000.0020.341.04924.77T3.502.165 SCHED 40 STEEL,DRY 1009.20010.505.011 I:\GVWF\12800\07\Lion Square Attic 1..fiw Wednesday, September 19, 2012, 4:06 PM FIRE - Fire Sprinkler Hydraulics Calculation Program Elite Software Development, Inc. A & A Fire Protection Lion Square Lodge-East Building-Attic 1 Glenwood Springs, CO 81611 Page 7 Fire Sprinkler Output Data Overall Pipe Output Data (cont'd) Beg. End. Node Nodal KFactor (K) Elevation (feet) Spk/Hose Discharge (gpm) Residual Pressure (psi) Nom. Dia. Inside Dia. C-Value q (gpm) Q (gpm) Velocity (fps) F. L./ft (psi/ft) Fittings Type-Grp Pipe-Len. Fit-Len. Tot-Len. (ft) PF-(psi) PE-(psi) PT-(psi) 2420.0057.000.0025.352.5013.940.148983.830.571 2462.8057.0013.9424.782.635202.49-----0.000.000 SCHD 10 STEEL, DRY 10011.9103.830.571 2430.0062.000.0020.341.0012.500.076451.920.414 2442.8062.0012.5019.931.04912.50T3.500.000 SCHED 40 STEEL,DRY 1004.6405.420.414 2430.0062.000.0020.341.0012.270.073926.580.693 2452.8063.0012.2719.221.04912.272E2.800.433 SCHED 40 STEEL,DRY 1004.5609.381.126 2462.8057.0013.9424.782.5013.560.1305610.171.328 2472.8057.0013.5623.462.635188.55-----0.000.000 SCHD 10 STEEL, DRY 10011.09010.171.328 2472.8057.0013.5623.462.0012.640.3014310.173.066 2482.8057.0012.6420.392.157174.99-----0.000.000 SCHD 10 STEEL, DRY 10015.36010.173.066 2482.8057.0012.6420.392.0011.790.2623810.172.668 2492.8057.0011.7917.722.157162.35-----0.000.000 SCHD 10 STEEL, DRY 10014.25010.172.668 2492.8057.0011.7917.722.0010.990.2282210.172.321 2502.8057.0010.9915.402.157150.56-----0.000.000 SCHD 10 STEEL, DRY 10013.22010.172.321 2502.8057.0010.9915.402.000.000.198373.750.744 2510.0057.000.0014.662.157139.57-----0.000.000 SCHD 10 STEEL, DRY 10012.2503.750.744 2510.0057.000.0014.661.000.000.150827.001.584 2520.0062.000.0010.911.04918.05T3.502.165 SCHED 40 STEEL,DRY 1006.70010.503.749 2510.0057.000.0014.662.000.000.153543.830.588 2550.0057.000.0014.072.157121.53-----0.000.000 SCHD 10 STEEL, DRY 10010.6703.830.588 2520.0062.000.0010.911.009.150.042931.830.229 2532.8062.009.1510.681.0499.15T3.500.000 SCHED 40 STEEL,DRY 1003.4005.330.229 2520.0062.000.0010.911.008.900.040756.580.382 2542.8063.008.9010.091.0498.902E2.800.433 SCHED 40 STEEL,DRY 1003.3009.380.815 I:\GVWF\12800\07\Lion Square Attic 1..fiw Wednesday, September 19, 2012, 4:06 PM FIRE - Fire Sprinkler Hydraulics Calculation Program Elite Software Development, Inc. A & A Fire Protection Lion Square Lodge-East Building-Attic 1 Glenwood Springs, CO 81611 Page 8 Fire Sprinkler Output Data Overall Pipe Output Data (cont'd) Beg. End. Node Nodal KFactor (K) Elevation (feet) Spk/Hose Discharge (gpm) Residual Pressure (psi) Nom. Dia. Inside Dia. C-Value q (gpm) Q (gpm) Velocity (fps) F. L./ft (psi/ft) Fittings Type-Grp Pipe-Len. Fit-Len. Tot-Len. (ft) PF-(psi) PE-(psi) PT-(psi) 2550.0057.000.0014.072.0010.360.153542.500.384 2562.8057.0010.3613.692.157121.53-----0.000.000 SCHD 10 STEEL, DRY 10010.6702.500.384 2562.8057.0010.3613.692.000.000.130211.330.173 2570.0057.000.0013.512.157111.17-----0.000.000 SCHD 10 STEEL, DRY 1009.7601.330.173 2570.0057.000.0013.511.000.000.161517.001.696 2580.0062.000.009.651.04918.73T3.502.165 SCHED 40 STEEL,DRY 1006.95010.503.861 2570.0057.000.0013.512.009.980.092568.830.817 2612.8057.009.9812.702.15792.44-----0.000.000 SCHD 10 STEEL, DRY 1008.1208.830.817 2580.0062.000.009.651.008.610.038331.830.204 2592.8062.008.619.451.0498.61T3.500.000 SCHED 40 STEEL,DRY 1003.1905.330.204 2580.0062.000.009.651.0010.120.051736.580.485 2602.8053.0010.1213.061.04910.122E2.80-3.897 SCHED 40 STEEL,DRY 1003.7609.38-3.412 2612.8057.009.9812.702.009.670.0749310.170.762 2622.8057.009.6711.932.15782.46-----0.000.000 SCHD 10 STEEL, DRY 1007.24010.170.762 2622.8057.009.6711.932.009.220.0594811.331.090 2012.8057.009.2210.842.15772.792E7.000.000 SCHD 10 STEEL, DRY 1006.39018.331.090 2410.0057.000.0027.613.000.000.202048.172.641 2630.0048.000.0034.153.260418.07E4.903.897 SCHD 10 STEEL, DRY 10016.07013.076.538 2630.0048.000.0034.153.000.000.2020422.006.607 2640.0048.000.0040.763.260418.07T10.700.000 SCHD 10 STEEL, DRY 10016.07032.706.607 2640.0048.000.0040.763.000.000.202044.253.021 2650.0044.000.0045.513.260418.07T10.701.732 SCHD 10 STEEL, DRY 10016.07014.954.753 2650.0044.000.0045.513.000.000.202044.923.156 2660.0044.000.0048.663.260418.07T10.700.000 SCHD 10 STEEL, DRY 10016.07015.623.156 I:\GVWF\12800\07\Lion Square Attic 1..fiw Wednesday, September 19, 2012, 4:06 PM FIRE - Fire Sprinkler Hydraulics Calculation Program Elite Software Development, Inc. A & A Fire Protection Lion Square Lodge-East Building-Attic 1 Glenwood Springs, CO 81611 Page 9 Fire Sprinkler Output Data Overall Pipe Output Data (cont'd) Beg. End. Node Nodal KFactor (K) Elevation (feet) Spk/Hose Discharge (gpm) Residual Pressure (psi) Nom. Dia. Inside Dia. C-Value q (gpm) Q (gpm) Velocity (fps) F. L./ft (psi/ft) Fittings Type-Grp Pipe-Len. Fit-Len. Tot-Len. (ft) PF-(psi) PE-(psi) PT-(psi) 2660.0044.000.0048.663.000.000.2020422.925.621 2670.0020.000.0064.683.260418.07E4.9010.392 SCHD 10 STEEL, DRY 10016.07027.8216.013 2670.0020.000.0064.683.000.000.2020416.834.390 2680.0020.000.0069.073.260418.07E4.900.000 SCHD 10 STEEL, DRY 10016.07021.734.390 2680.0020.000.0069.073.000.000.2020433.837.825 2690.0020.000.0076.893.260418.07E4.900.000 SCHD 10 STEEL, DRY 10016.07038.737.825 2690.0020.000.0076.893.000.000.202049.502.909 2700.0020.000.0079.803.260418.07E4.900.000 SCHD 10 STEEL, DRY 10016.07014.402.909 2700.0020.000.0079.803.000.000.2020421.335.300 2710.0020.000.0085.103.260418.07E4.900.000 SCHD 10 STEEL, DRY 10016.07026.235.300 2710.0020.000.0085.103.000.000.2020410.923.196 2720.0020.000.0088.303.260418.07E4.900.000 SCHD 10 STEEL, DRY 10016.07015.823.196 2720.0020.000.0088.303.000.000.2020424.927.015 2730.008.000.00100.513.260418.072E9.805.196 SCHD 10 STEEL, DRY 10016.07034.7212.211 2730.008.000.00100.513.000.000.202047.685.290 2740.008.000.00105.803.260418.07TBG18.500.000 SCHD 10 STEEL, DRY 10016.07026.185.290 I:\GVWF\12800\07\Lion Square Attic 1..fiw Wednesday, September 19, 2012, 4:06 PM FIRE - Fire Sprinkler Hydraulics Calculation Program Elite Software Development, Inc. A & A Fire Protection Lion Square Lodge-East Building-Attic 1 Glenwood Springs, CO 81611 Page 10 Fire Sprinkler Output Data Overall Sprinkler Output Data Flowing Sprinkler Node No. Area Group Code Sprinkler KFactor (K) Sprinkler Elevation (feet) Residual Pressure (psi) Flowing Area (ft²) Flowing Density (gpm/ft²) Sprinkler Discharge (gpm) 201 2.8057.0010.8472.000.1289.22 Sub Totals For Non-Group 72.000.1289.22 203 2.8062.007.7872.000.1087.81 Sub Totals For Non-Group 72.000.1087.81 204 2.8057.0010.0872.000.1238.89 Sub Totals For Non-Group 72.000.1238.89 205 2.8057.009.6772.000.1218.71 Sub Totals For Non-Group 72.000.1218.71 207 2.8062.007.0872.000.1037.45 Sub Totals For Non-Group 72.000.1037.45 208 2.8057.009.5372.000.1208.64 Sub Totals For Non-Group 72.000.1208.64 209 2.8057.009.4772.000.1208.62 Sub Totals For Non-Group 72.000.1208.62 211 2.8062.007.0072.000.1037.41 Sub Totals For Non-Group 72.000.1037.41 212 2.8057.009.4672.000.1208.61 Sub Totals For Non-Group 72.000.1208.61 213 2.8057.009.4672.000.1208.61 Sub Totals For Non-Group 72.000.1208.61 215 2.8062.007.0672.000.1037.44 Sub Totals For Non-Group 72.000.1037.44 216 2.8057.009.5372.000.1208.64 Sub Totals For Non-Group 72.000.1208.64 217 2.8057.009.6072.000.1208.67 Sub Totals For Non-Group 72.000.1208.67 218 2.8057.009.7172.000.1218.73 Sub Totals For Non-Group 72.000.1218.73 220 2.8062.007.5072.000.1077.67 Sub Totals For Non-Group 72.000.1077.67 221 2.8057.0010.1272.000.1248.91 Sub Totals For Non-Group 72.000.1248.91 222 2.8057.0010.7872.000.1289.19 Sub Totals For Non-Group 72.000.1289.19 224 2.8062.008.6372.000.1148.22 I:\GVWF\12800\07\Lion Square Attic 1..fiw Wednesday, September 19, 2012, 4:06 PM FIRE - Fire Sprinkler Hydraulics Calculation Program Elite Software Development, Inc. A & A Fire Protection Lion Square Lodge-East Building-Attic 1 Glenwood Springs, CO 81611 Page 11 Fire Sprinkler Output Data Overall Sprinkler Output Data (cont'd) Flowing Sprinkler Node No. Area Group Code Sprinkler KFactor (K) Sprinkler Elevation (feet) Residual Pressure (psi) Flowing Area (ft²) Flowing Density (gpm/ft²) Sprinkler Discharge (gpm) Sub Totals For Non-Group 72.000.1148.22 225 2.8057.0011.2872.000.1319.40 Sub Totals For Non-Group 72.000.1319.40 226 2.8057.0012.0172.000.1359.70 Sub Totals For Non-Group 72.000.1359.70 228 2.8062.009.6372.000.1218.69 Sub Totals For Non-Group 72.000.1218.69 229 2.8057.0012.9972.000.14010.09 Sub Totals For Non-Group 72.000.14010.09 230 2.8057.0015.2272.000.15210.92 Sub Totals For Non-Group 72.000.15210.92 232 2.8062.0013.1372.000.14110.15 Sub Totals For Non-Group 72.000.14110.15 235 2.8057.0023.9772.000.19013.71 Sub Totals For Non-Group 72.000.19013.71 238 2.8062.0020.4972.000.17612.67 Sub Totals For Non-Group 72.000.17612.67 239 2.8063.0019.9072.000.17312.49 Sub Totals For Non-Group 72.000.17312.49 240 2.8057.0026.1672.000.19914.32 Sub Totals For Non-Group 72.000.19914.32 244 2.8062.0019.9372.000.17412.50 Sub Totals For Non-Group 72.000.17412.50 245 2.8063.0019.2272.000.17012.27 Sub Totals For Non-Group 72.000.17012.27 246 2.8057.0024.7872.000.19413.94 Sub Totals For Non-Group 72.000.19413.94 247 2.8057.0023.4672.000.18813.56 Sub Totals For Non-Group 72.000.18813.56 248 2.8057.0020.3972.000.17612.64 Sub Totals For Non-Group 72.000.17612.64 249 2.8057.0017.7272.000.16411.79 Sub Totals For Non-Group 72.000.16411.79 250 2.8057.0015.4072.000.15310.99 Sub Totals For Non-Group 72.000.15310.99 I:\GVWF\12800\07\Lion Square Attic 1..fiw Wednesday, September 19, 2012, 4:06 PM FIRE - Fire Sprinkler Hydraulics Calculation Program Elite Software Development, Inc. A & A Fire Protection Lion Square Lodge-East Building-Attic 1 Glenwood Springs, CO 81611 Page 12 Fire Sprinkler Output Data Overall Sprinkler Output Data (cont'd) Flowing Sprinkler Node No. Area Group Code Sprinkler KFactor (K) Sprinkler Elevation (feet) Residual Pressure (psi) Flowing Area (ft²) Flowing Density (gpm/ft²) Sprinkler Discharge (gpm) 253 2.8062.0010.6872.000.1279.15 Sub Totals For Non-Group 72.000.1279.15 254 2.8063.0010.0972.000.1248.90 Sub Totals For Non-Group 72.000.1248.90 256 2.8057.0013.6972.000.14410.36 Sub Totals For Non-Group 72.000.14410.36 259 2.8062.009.4572.000.1208.61 Sub Totals For Non-Group 72.000.1208.61 260 2.8053.0013.0672.000.14110.12 Sub Totals For Non-Group 72.000.14110.12 261 2.8057.0012.7072.000.1399.98 Sub Totals For Non-Group 72.000.1399.98 262 2.8057.0011.9372.000.1349.67 Sub Totals For Non-Group 72.000.1349.67 Totals For All Groups 3024.000.138418.07 I:\GVWF\12800\07\Lion Square Attic 1..fiw Wednesday, September 19, 2012, 4:06 PM FIRE - Fire Sprinkler Hydraulics Calculation Program Elite Software Development, Inc. A & A Fire Protection Lion Square Lodge-East Building-Attic 1 Glenwood Springs, CO 81611 Page 13 Fire Sprinkler Output Summary Hydraulically Most Demanding Sprinkler Node HMD Sprinkler Node Number:211 HMD Actual Residual Pressure:7.00psi HMD Actual GPM:7.41gpm Sprinkler Summary Sprinkler System Type:Dry Specified Area Of Application:2567.00ft² Adjusted Area Of Application:3337.10ft² Minimum Desired Density:0.100gpm/ft² Application Average Density:0.163gpm/ft² Application Adjusted Density (not required by NFPA 13):0.125gpm/ft² Application Average Area Per Sprinkler:61.12ft² Adjusted Area Per Sprinkler (not required by NFPA 13):79.45ft² Sprinkler Flow:418.07gpm Average Sprinkler Flow:9.95gpm Flow Velocity And Imbalance Summary Maximum Flow Velocity ( In Pipe 241 - 263 )16.07ft/sec Maximum Velocity Pressure ( In Pipe 241 - 263 )1.74psi Allowable Maximum Nodal Pressure Imbalance:0.0000psi Actual Maximum Nodal Pressure Imbalance:0.0000psi Actual Average Nodal Pressure Imbalance:0.0000psi Actual Maximum Nodal Flow Imbalance:0.0000gpm Actual Average Nodal Flow Imbalance:0.0000gpm Overall Network Summary Number Of Unique Pipe Sections:80 Number Of Flowing Sprinklers:42 Pipe System Water Volume:192.85gal Sprinkler Flow:418.07gpm Non-Sprinkler Flow:0.00gpm Minimum Required Residual Pressure At System Inflow Node:122.14psi Demand Flow At System Inflow Node:418.07gpm I:\GVWF\12800\07\Lion Square Attic 1..fiw Wednesday, September 19, 2012, 4:06 PM FIRE - Fire Sprinkler Hydraulics Calculation Program Elite Software Development, Inc. A & A Fire Protection Lion Square Lodge-East Building-Attic 1 Glenwood Springs, CO 81611 Page 14 Fire Sprinkler Output Data Hydraulic Supply/Demand Graph Pr e s s u r e p s i Flowrate(x100) gpm 150 140 114 0 20 40 60 80 100 120 140 160 180 200 1 2 3 4 5 6 7 8 9 10 Supply Curve Data Static Pressure: 150 psi Test Residual Pressure: 140 psi Test Flow Rate: 500 gpm Demand Curve Data Calculated Residual Pressure: 122.14 psi Calculated Flow Rate: 418.07 gpm Excess Available Residual Pressure At Calculated Flow: 20.68 psi Pressure Required For First Sprinkler Downstream From Inflow Node To Flow: 28.38 psi I:\GVWF\12800\07\Lion Square Attic 1..fiw Wednesday, September 19, 2012, 4:06 PM