HomeMy WebLinkAboutF12-0060 Calc 1 signedFIRE - Fire Sprinkler Hydraulics Calculation ProgramElite Software Development, Inc. A & A Fire Protection Lion Square Lodge-East, Residential #1 New Castle, CO 81647 Page 2 General Project Data Report General Data Project Title:Lion Square Lodge-East, Residential #1 Project File Name:Lion Square Residential 1..fiw Designed By:Bojar VodaDate:9/16/2012 Code Reference:NFPA 13Approving Agency:VFPD Client Name:J.L.Viele ConstructionPhone:(970) 476-3082 Address:1000 South Frontage Road West Suite 202 City, State Zip Code:Vail, Colorado 81657 Company Name:Sprinklers R Us, Inc.Representative:Bojar Voda Company Address:0035 Apache TrailCity And State:Carbondale, CO 81623 Phone:(970) 963-8752 Building Name:Lions Square Lodge, East BuilidngBuilding Owner: Contact at Building:MarkPhone at Building: Address Of Building:Lionshead PlaceCity, State Zip Code:Vail, Colorado, 81657 Project Data Description Of Hazard:NFPA 13Sprinkler System Type:Wet Design Area Of Water Application:784ft²Maximum Area Per Sprinkler:196ft² Default Sprinkler K-Factor:4.90KDefault Pipe Material:TYPE M COPPER TUBE Inside Hose Stream Allowance:0.00gpmOutside Hose Stream Allowance:100.00gpm In Rack Sprinkler Allowance:0.00gpm Sprinkler Specifications Make:TYCOModel:LFII Size:1/2"Temperature Rating:155F NONE Water Supply Test Data Source Of Information: Test Hydrant ID:Date Of Test: Hydrant Elevation:0ftStatic Pressure:150.00psi Test Flow Rate:500.00gpmTest Residual Pressure:140.00psi Calculated System Flow Rate:81.85gpmCalculated Inflow Residual Pressure:93.48psi Available Residual Pressure At System Flow:149.65psi Calculation Project Data Calculation Mode:Demand HMD Minimum Residual Pressure:7.00psiMinimum Desired Flow Density:0.10gpm/ft² Maximum Water Velocity:20.00ft/sMaximum Frictional Loss / 100 feet:20.00psi Number Of Active Nodes:26 Number Of Active Pipes:25Number Of Inactive Pipes:0 Number Of Active Sprinklers:4Number Of Inactive Sprinklers:0 C:\Users\Bojar\Documents\Elite Software\Fire 6 Projects\Lion Square Residential 1..fiwThursday, September 20, 2012, 5:42 AM FIRE - Fire Sprinkler Hydraulics Calculation ProgramElite Software Development, Inc. A & A Fire Protection Lion Square Lodge-East, Residential #1 Glenwood Springs, CO 81611 Page 3 Fire Sprinkler Output Data Overall Pipe Output Data Beg. End. Node Nodal KFactor (K) Elevation (feet) Spk/Hose Discharge (gpm) Residual Pressure (psi) Nom. Dia. Inside Dia. C-Value q (gpm) Q (gpm) Velocity (fps) F. L./ft (psi/ft) Fittings Type-Grp Pipe-Len. Fit-Len. Tot-Len. (ft) PF-(psi) PE-(psi) PT-(psi) 14.9044.0020.1116.851.0020.110.0846711.001.185 20.0044.000.0018.031.05520.11E3.000.000 TYPE M COPPER TUBE1507.38014.001.185 20.0044.000.0018.030.7519.600.290602.502.034 34.9044.0019.6016.000.81119.60T4.500.000 TYPE M COPPER TUBE15012.1707.002.034 20.0044.000.0018.031.000.000.298110.502.385 40.0044.000.0020.421.05539.71T7.500.000 TYPE M COPPER TUBE15014.5808.002.385 40.0044.000.0020.421.0021.060.0921710.671.951 54.9044.0021.0618.471.05521.06ET10.500.000 TYPE M COPPER TUBE1507.73021.171.951 40.0044.000.0020.421.500.000.108186.001.947 60.0046.000.0021.501.52760.772E12.00-0.866 TYPE M COPPER TUBE15010.65018.001.081 60.0046.000.0021.500.7521.080.332504.502.992 9994.9046.0021.0818.510.81121.08T4.500.000 TYPE M COPPER TUBE15013.0909.002.992 60.0046.000.0021.501.500.000.1876913.834.867 70.0053.000.0023.341.52781.85T12.10-3.031 TYPE M COPPER TUBE15014.34025.931.836 70.0053.000.0023.341.500.000.187692.251.548 80.0053.000.0024.881.52781.85E6.000.000 TYPE M COPPER TUBE15014.3408.251.548 80.0053.000.0024.881.500.000.187699.502.909 90.0043.000.0032.121.52781.85E6.004.330 TYPE M COPPER TUBE15014.34015.507.239 90.0043.000.0032.121.500.000.187692.582.755 100.0043.000.0034.881.52781.85T12.100.000 TYPE M COPPER TUBE15014.34014.682.755 100.0043.000.0034.881.500.000.1876912.424.602 110.0043.000.0039.481.52781.85T12.100.000 TYPE M COPPER TUBE15014.34024.524.602 110.0043.000.0039.481.500.000.187694.834.304 120.0043.000.0043.781.52781.85ET18.100.000 TYPE M COPPER TUBE15014.34022.934.304 F:\Lyons Square\Lion Square Residential 1..fiwWednesday, September 19, 2012, 4:10 PM FIRE - Fire Sprinkler Hydraulics Calculation ProgramElite Software Development, Inc. A & A Fire Protection Lion Square Lodge-East, Residential #1 Glenwood Springs, CO 81611 Page 4 Fire Sprinkler Output Data Overall Pipe Output Data (cont'd) Beg. End. Node Nodal KFactor (K) Elevation (feet) Spk/Hose Discharge (gpm) Residual Pressure (psi) Nom. Dia. Inside Dia. C-Value q (gpm) Q (gpm) Velocity (fps) F. L./ft (psi/ft) Fittings Type-Grp Pipe-Len. Fit-Len. Tot-Len. (ft) PF-(psi) PE-(psi) PT-(psi) 120.0043.000.0043.781.500.000.187697.676.526 130.0037.000.0052.911.52781.85ETB27.102.598 TYPE M COPPER TUBE15014.34034.779.124 130.0037.000.0052.912.000.000.0649116.001.688 140.0021.000.0061.522.06781.85T10.006.928 SCHED 40 WET STEEL1207.83026.008.616 140.0021.000.0061.522.000.000.0649123.002.142 150.0021.000.0063.672.06781.852E10.000.000 SCHED 40 WET STEEL1207.83033.002.142 150.0021.000.0063.672.000.000.0649137.333.721 160.0019.000.0068.252.06781.854E20.000.866 SCHED 40 WET STEEL1207.83057.334.587 160.0019.000.0068.252.000.000.06491129.179.033 170.0019.000.0077.292.06781.852E10.000.000 SCHED 40 WET STEEL1207.830139.179.033 170.0019.000.0077.292.000.000.0649110.921.358 180.007.000.0083.842.06781.85T10.005.196 SCHED 40 WET STEEL1207.83020.926.554 180.007.000.0083.842.000.000.064916.831.092 190.007.000.0084.932.06781.852E10.000.000 SCHED 40 WET STEEL1207.83016.831.092 190.007.000.0084.932.000.000.052746.581.349 200.001.000.0088.882.15781.85TB19.002.598 SCHED 10 WET STEEL1207.19025.583.947 200.001.000.0088.884.000.000.001923.500.032 210.007.000.0086.314.26081.85E13.00-2.598 SCHED 10 WET STEEL1201.84016.50-2.566 21 Backflo Prev 7.0086.3181.85 225.00 psi7.0091.31 220.007.000.0091.314.000.000.001927.080.113 230.008.000.0091.004.26081.852ET52.00-0.433 SCHED 10 WET STEEL1201.84059.08-0.320 230.008.000.0091.004.000.000.0018717.600.146 240.008.000.0091.143.93581.854E60.400.000 TYPE M COPPER TUBE1502.16078.000.146 F:\Lyons Square\Lion Square Residential 1..fiwWednesday, September 19, 2012, 4:10 PM FIRE - Fire Sprinkler Hydraulics Calculation ProgramElite Software Development, Inc. A & A Fire Protection Lion Square Lodge-East, Residential #1 Glenwood Springs, CO 81611 Page 5 Fire Sprinkler Output Data Overall Pipe Output Data (cont'd) Beg. End. Node Nodal KFactor (K) Elevation (feet) Spk/Hose Discharge (gpm) Residual Pressure (psi) Nom. Dia. Inside Dia. C-Value q (gpm) Q (gpm) Velocity (fps) F. L./ft (psi/ft) Fittings Type-Grp Pipe-Len. Fit-Len. Tot-Len. (ft) PF-(psi) PE-(psi) PT-(psi) 240.008.000.0091.144.000.000.0018745.000.172 250.003.000.0093.483.93581.85ETG46.902.165 TYPE M COPPER TUBE1502.16091.902.337 F:\Lyons Square\Lion Square Residential 1..fiwWednesday, September 19, 2012, 4:10 PM FIRE - Fire Sprinkler Hydraulics Calculation ProgramElite Software Development, Inc. A & A Fire Protection Lion Square Lodge-East, Residential #1 Glenwood Springs, CO 81611 Page 6 Fire Sprinkler Output Data Overall Sprinkler Output Data Flowing Sprinkler Node No. Area Group Code Sprinkler KFactor (K) Sprinkler Elevation (feet) Residual Pressure (psi) Flowing Area (ft²) Flowing Density (gpm/ft²) Sprinkler Discharge (gpm) 14.9044.0016.85196.000.10320.11 Sub Totals For Non-Group196.000.10320.11 34.9044.0016.00196.000.10019.60 Sub Totals For Non-Group196.000.10019.60 54.9044.0018.47196.000.10721.06 Sub Totals For Non-Group196.000.10721.06 9994.9046.0018.51196.000.10821.08 Sub Totals For Non-Group196.000.10821.08 Totals For All Groups784.000.10481.85 F:\Lyons Square\Lion Square Residential 1..fiwWednesday, September 19, 2012, 4:10 PM FIRE - Fire Sprinkler Hydraulics Calculation ProgramElite Software Development, Inc. A & A Fire Protection Lion Square Lodge-East, Residential #1 New Castle, CO 81647 Page 7 Fire Sprinkler Output Summary Hydraulically Most Demanding Sprinkler Node HMD Sprinkler Node Number:3 HMD Actual Residual Pressure:16.00psi HMD Actual GPM:19.60gpm Sprinkler Summary Sprinkler System Type:Wet Specified Area Of Application:784.00ft² Minimum Desired Density:0.100gpm/ft² Application Average Density:0.104gpm/ft² Application Average Area Per Sprinkler:196.00ft² Sprinkler Flow:81.85gpm Average Sprinkler Flow:20.46gpm Flow Velocity And Imbalance Summary Maximum Flow Velocity ( In Pipe 0 - 0 )0.00ft/sec Maximum Velocity Pressure ( In Pipe 0 - 0 )0.00psi Allowable Maximum Nodal Pressure Imbalance:0.0000psi Actual Maximum Nodal Pressure Imbalance:0.0000psi Actual Average Nodal Pressure Imbalance:0.0000psi Actual Maximum Nodal Flow Imbalance:0.0000gpm Actual Average Nodal Flow Imbalance:0.0000gpm Overall Network Summary Number Of Unique Pipe Sections:25 Number Of Flowing Sprinklers:4 Pipe System Water Volume:94.36gal Sprinkler Flow:81.85gpm Non-Sprinkler Flow:0.00gpm Minimum Required Residual Pressure At System Inflow Node:93.48psi Demand Flow At System Inflow Node:81.85gpm C:\Users\Bojar\Documents\Elite Software\Fire 6 Projects\Lion Square Residential 1..fiwThursday, September 20, 2012, 5:54 AM FIRE - Fire Sprinkler Hydraulics Calculation ProgramElite Software Development, Inc. A & A Fire Protection Lion Square Lodge-East, Residential #1 Glenwood Springs, CO 81611 Page 8 Fire Sprinkler Output Data Hydraulic Supply/Demand Graph Pr e s s u r e p s i Flowrate(x100) gpm 150 140 114 0 20 40 60 80 100 120 140 160 180 200 1 2 3 4 5 6 7 8 9 10 Supply Curve Data Static Pressure: 150 psi Test Residual Pressure: 140 psi Test Flow Rate: 500 gpm Demand Curve Data Calculated Residual Pressure: 93.48 psi Calculated Flow Rate: 81.85 gpm Excess Available Residual Pressure At Calculated Flow: 56.17 psi Pressure Required For First Sprinkler Downstream From Inflow Node To Flow: 23.62 psi F:\Lyons Square\Lion Square Residential 1..fiwWednesday, September 19, 2012, 4:10 PM