Loading...
HomeMy WebLinkAboutA12-0057 CUT SHEETS1122//2244VVDDCC,, LLooww CCuurrrreenntt MMiinnii--HHoorrnn wwiitthh TTeerrmmiinnaall BBlloocckkss G X 9 3 S E R I E SAApppplliiccaattiioonnss The GX93 Series mini-horn is a high quality remote audible signaling appliance that offers dependable remote annunciation. The GX93 is ideal for applications where a dependable audible alarm signal is required in applications such as hotels, dormitories and apartments. The GX93 is listed for use with both filtered and unfiltered power and a jumper is provided to select either temporal 3 or continuous tone. The GX93 can be used on the same sync circuit (AVSM Series Control Module) as other Gentex signals. The GX93 Series is ANSI/UL 464 listed for use with fire protective systems and are warranted for three years from the date of purchase. •AANNSSII//UULL 446644 LLiisstteedd •CCSSFFMM LLiissttiinngg 77113355--00556699::112266 •BBFFPP ((CCiittyy ooff CChhiiccaaggoo)) •MMEEAA ##228855--9911--EE--XXVVII Standard Features •Single unit is capable of 12 or 24 VDC determined by the input voltage •Unit dimensions: 4.48” (11.38 cm) high x 2.84” (7.21 cm) wide x 0.5” (1.27 cm) deep •Jumper selectable temporal 3 or continuous tone •Horn frequency is 3100Hz •Terminal blocks (12 AWG to 18 AWG) •Low current consumption •Variety of mounting options for new construction and retrofit applications •Synchronize using the Gentex AVSM Series control module (see Technical Bulletin 015) •ANSI/UL 464 listed for fire protective service •Textured finish high impact plastic faceplate, available in red or off- white NOTES:The sound output for the temporal 3 tone is rated lower since the time the horn is off is averaged into the sound output rating. While the horn is producing a tone in the temporal 3 mode its sound pressure is the same as the continuous mode. Operating temperature - IInnddoooorr uussee oonnllyy Indoor: 32° to 120°F (0° to 49°C) 1 RMS current ratings are per ANSI/UL average RMS method. ANSI/UL max current rating is the maximum RMS current within the listed voltage range (16-33VDC for 24VDC units) (8-17VDC for 12VDC units). For strobes the ANSI/UL max current is usually at the minimum listed voltage (16VDC for 24VDC units) (8VDC for 12VDC units). For audibles the max current is usually at the maximum listed voltage. For unfiltered FWR ratings, see installation manual. MMooddeell NNuummbbeerr PPaarrtt NNuummbbeerr GX93-R 904-1276-002 GX93-W 904-1277-002 GX93-PR 904-1267-002 GX93-PW 904-1268-002 Model Designations “R”=Red faceplate “W”=Off-White faceplate "P"=Plain GGXX9933 CCuurrrreenntt RRaattiinnggss 2244 VVDDCC 2222mmAA 24VDC UL Max1 18mA 12VDC UL Max1 13mA HHoorrnn MMooddee MMiinniimmuumm SSPPLL aatt 1100 ffeeeett ppeerr AANNSSII//UULL 446644 aatt 2244VVDDCC MMiinniimmuumm SSPPLL aatt 1100 ffeeeett ppeerr AANNSSII//UULL446644 aatt 1122VVDDCC RReevveerrbbeerraanntt ddBBAA aatt 1100 ffeeeett ppeerr AANNSSII//UULL 446644 IInn AAnneecchhooiicc RRoooomm ddBBAA @@ 1100fftt.. Temporal 3 81 dBA 78 dBA 78-86 90 Continuous 86 dBA 83 dBA 78-86 90 Product Listings Product Compliance ••NNFFPPAA 7722 ••IIBBCC//IIFFCC//IIRRCC ••QQuuaalliittyy MMaannaaggeemmeenntt SSyysstteemm iiss cceerrttiiffiieedd ttoo:: IISSOO 99000011::22000088 551-0032-03Important Notice: These materials have been prepared by Gentex Corporation ("Gentex") for informational purposes only, are necessarily summary, and are not purported to serve as legal advice and should not be used as such. Gen- tex makes no representations and warranties, express or implied, that these materials are complete and ac- curate, up-to-date, or in compliance with all relevant local, state and federal laws, regulations and rules. The materials do not address all legal considerations as there is inevitable uncertainty regarding interpretation of laws, regulations and rules and the application of such laws, regulations and rules to particular fact patterns. Each person's activities can differently affect the obligations that exist under applicable laws, regulations or rules. Therefore, these materials should be used only for informational purposes and should not be used as a substitute for seeking professional legal advice. Gentex will not be responsible for any action or failure to act in reliance upon the information contained in this material. 24 units per carton 6 pounds per carton G X 9 3 S E R I E S Architect & Engineering Specifications The alarm horns shall be Gentex model GX93. The appliance shall be listed with Underwriters Laboratories (ANSI/UL) for use with fire protective signaling systems (ANSI/UL 464) and produce a peak sound output of 90dBA or greater as measured in an anechoic chamber. The appliance shall be of solid-state construction and be polarized to operate from 8-33VDC with a 22mA current drain at 24VDC. The appliance shall be provided with 2 terminals, and mount to a variety of single-gang back boxes. Mini-Horn MountingMini-Horn Wiring Use screwdriver to break jumper for continuous tone. DDOO NNOOTT BBRREEAAKK JJUUMMPPEERR IIFF TTEEMMPPOORRAALL 33 TTOONNEE IISS NNEEEEDDEEDD.. G N -5 0 3 S E R I E S Standard Product Features •GN-503 available in 120VAC with 9VDC battery back-up •Horn frequency 3100 Hz (nominal) •Meets sensitivity requirements of ANSI/UL 2034 •F Model:One (1)set of Form A/Form C contacts that activate for smoke and/or CO events ••FFFF MMooddeell:: TTwwoo ((22)) sseettss ooff FFoorrmm AA//FFoorrmm CC ccoonnttaaccttss tthhaatt aaccttiivvaattee iinnddeeppeennddeennttllyy ffoorr ssmmookkee aanndd CCOO eevveennttss •Relay contacts operate on battery back-up •Push button self test feature •Push button functional test feature •Quick-disconnect wiring harness •Non-latching (self restoring) alarm •Fully insect protected •Red LED pulses every 30 seconds, green LED for AC power on •Mounting hardware adapts to standard junction boxes, including but not limited to 4x4x2-1/8 octagon •Dust cover to prevent contamination during installation •Low or missing battery indicator •1 year warranty from date of purchase •5 year limited warranty on CO sensor Additional Smoke Alarm Features •Photoelectric smoke sensing technology •Temporal 3 evacuation sounding pattern for smoke annunciation •Nominal 2.5% sensitivity (smoke) •Solid state red LED to indicate smoke presence Additional CO Alarm Features •Electrochemical sensor •Temporal 4 sounding pattern for CO annunciation •End of life signal indicates CO sensor has reached depletion state and unit must be replaced •• AANNSSII//UULL 221177 aanndd AANNSSII//UULL 22003344 LLiisstteedd •• CCSSFFMM ## 55227766--00556699::114444 Combination Photoelectric Smoke and Carbon Monoxide Alarm 120VAC/9VDC Single/Multiple Station Smoke and CO Alarm Product Listings Applications The GN-503 (120VAC/9VDC) Series of combination photoelectric smoke and electrochemical sensor carbon monoxide alarms are for use as evacuation devices in all dwelling units, including but not limited to homes, apartments, hospitals, hotels, motels and other commercial occupancies. The GN-503 Series is listed in compliance with ANSI/UL 217, ANSI/UL 2034, for installation per NFPA 720 and NFPA 72. Available in three models, the GN-503 Series is engineered to virtually eliminate nuisance alarms and deliver outstanding performance wherever reliable smoke and CO protection is required. The GN-503F features one (1) set of Form A/Form C contacts that activate for smoke and/or CO events. TTHHEE GGNN--550033FFFF FFEEAATTUURREESS TTWWOO ((22)) SSEETTSS OOFF FFOORRMM AA// FFOORRMM CC CCOONNTTAACCTTSS TTHHAATT AACCTTIIVVAATTEE IINNDDEEPPEENNDDEENNTTLLYY FFOORR SSMMOOKKEE AANNDD CCOO EEVVEENNTTSS.. Both the GN-503F and GN-503FF provide a connection to a protected premises alarm system to provide a supervisory/trouble signal. The GN-503 Series is provided with a 9VDC alkaline battery for electrical back-up in the event building power is lost. The battery impedance is verified and the alarm provides a low or missing battery warning. The battery drawer provides easy replacement without removing the unit from the wall or ceiling. The GN-503 Series is designed with a self test feature that quickly notifies if the alarm is functioning properly or needs attention (signified by a series of chirps) by simply pressing the test button. The functionality tests that the smoke/CO alarm is operating properly (signified by going into alarm). The self and functionality tests are in compliance with NFPA 72, NFPA 720 and ANSI/UL Standards. The GN-503 Series provides a temporal 3 evacuation tone for smoke alarm annunciation and all units provide a temporal 4 tone for CO alarm annunciation. Per NFPA 720, the temporal 3 evacuation tone for smoke alarm will take precedence over the temporal 4 tone for CO alarm. •• NNFFPPAA 7722 aanndd NNFFPPAA 772200 •• IIBBCC//IIFFCC//IIRRCC •• CCiittyy && SSttaattee OOrrddiinnaanncceess//LLaawwss//RReegguullaattiioonnss •• QQuuaalliittyy MMaannaaggeemmeenntt SSyysstteemm iiss cceerrttiiffiieedd ttoo:: IISSOO 99000011::22000088 Product Compliance NN EE WW FF EE AA TT UU RR EE SS MMooddeell NNuummbbeerr VVoollttaaggee 99VVDDCC BBaatttteerryy BBaacckk--UUpp OOnnee ((11)) SSeett FFoorrmm AA// FFoorrmm CC RReellaayy CCoonnttaaccttss TTwwoo ((22)) SSeettss FFoorrmm AA// FFoorrmm CC RReellaayy CCoonnttaaccttss GN-503 120VAC GN-503F 120VAC GN-503FF 120VAC GN-503 AND GN-503F Wiring Diagrams GN-503 Series Combination Smoke/CO Alarm GN-503/GN-503F ADDITIONAL PRODUCT INFORMATION THE GN-503F AND GN-503FF PRODUCT WIRING HARNESS IS NOT INTERCHANGEABLE. THE GN-503F AND GN-503FF MUST USE PROPER WIRING HARNESS. PRODUCT WILL NOT FUNCTION IF INCORRECT HARNESS IS USED. DO NOT connect Gentex alarms to other manufacturers’ alarms. Per NFPA 72, a maximum of 18 compatible smoke, heat, CO and/or combination smoke/CO alarms may be interconnected. No more than 12 of the 18 can be smoke alarms. All units connected in tandem MUST get their power from the same circuit, that is, all smoke alarms in tandem must be controlled by the same fuse or circuit breaker. NOTICE: PER NFPA 72, A MAXIMUM OF 12 SMOKE/CO ALARMS OF GN-503 WITH THE RELAY OPTION (F) MAY BE TANDEM INTERCONNECTED. The GN-503/GN-503F may be tandem interconnected with other Gentex tandem capable smoke alarms, CO alarms or smoke/CO alarms. To interconnect with Gentex 9000 Series, 7000 Series, 710CS Series, 7109CS Series, GN-200 Series & GN-300 Series the LEGACY TANDEM WIRE must be used. Refer to installation manual for detailed information. CCAAUUTTIIOONN::RED/YELLOW & BROWN/YELLOW wire to be capped when not in use. This wire is for tandem connection only. Do not connect to any other circuit. If a GN-503 Series or CO1209 Series unit is annunciating for a CO event, legacy products that are tandem interconnected will not activate and will remain silent. If smoke alarm portion of device goes into alarm, all smoke alarms, CO alarms or combination smoke/CO alarms tandem wired will sound smoke alarm warning. When both smoke and CO conditions are present, smoke condition will have priority and alarm will sound smoke annunciation. PLUGSMOKE/CO ALARM BLK WHT RED / YEL VIO VIO / BLK BLU ORN YEL GRAY GRAY HOT NEUT POWER TANDEM - LEGACY ALARM CONTACTS ACCESSORY ALARM CONTACTS INTERNAL JUMPER BRN / YEL TANDEM ELECTRICAL BOX SMOKE/COALARM QUICK DISCONNECTTYPE PLUG HOT / BLACK NEUTRAL / WHITE TANDEM WIREBRN / YEL SMOKEALARM SMOKE/COALARM ELECTRICAL BOX ELECTRICAL BOX TANDEM WIRE RED / YEL(LEGACY) (LEGACY) USING THE GENTEX GN-503FF COMBINATION SMOKE AND CARBON MONOXIDE ALARM ALLOWS THE ABILITY TO: • Interface with a FACP Panel • Interface with NAC Circuits GN-503FF ADDITIONAL PRODUCT INFORMATION Use brown/yellow wire to tandem interconnect GN-503FF alarms to additional GN-503 Series, S1209 Series and CO1209 Series. NOTICE: THE GN-503FF IS ONLY CAPABLE OF TANDEM INTERCONNECT WITH GN-503 SERIES, CO1209 SERIES AND S1209 SERIES. THE GN-503F AND GN-503FF PRODUCT WIRING HARNESS IS NOT INTERCHANGEABLE. THE GN-503F AND GN-503FF MUST USE PROPER WIRING HARNESS. PRODUCT WILL NOT FUNCTION IF INCORRECT HARNESS IS USED. DO NOT connect Gentex alarms to other manufacturers’ alarms. Per NFPA 72, a maximum of 18 compatible smoke, heat, CO and/or combination smoke/CO alarms may be interconnected. No more than 12 of the 18 can be smoke alarms. All units connected in tandem MUST get their power from the same circuit, that is, all smoke alarms in tandem must be controlled by the same fuse or circuit breaker. NOTICE: PER NFPA 72, A MAXIMUM OF 12 SMOKE/CO ALARMS OF GN-503 WITH THE RELAY OPTION (FF) MAY BE TANDEM INTERCONNECTED. CCAAUUTTIIOONN::BROWN/YELLOW wire to be capped when not in use. This wire is for tandem connection only. Do not connect to any other circuit. If smoke alarm portion of device goes into alarm, all smoke alarms, CO alarms or combination smoke/CO alarms tandem wired will sound smoke alarm warning. When both smoke and CO conditions are present, smoke condition will have priority and alarm will sound smoke annunciation. GN-503FF Wiring Diagrams PLUGSMOKE/CO ALARM BLK WHT VIO VIO ORN YEL HOT NEUT POWER SMOKE ALARM CONTACTS (FORM A CONTACT) BRN / YEL TANDEM SMOKE FORM C COMMON SMOKE NORMALLY CLOSED CO ALARM CONTACTS (FORM A CONTACT) PINK PINK BLU GRAY VIO / YEL FORM CALARM CONTACTSSMOKE & CO NORMALLY OPEN CO FORM C COMMON CO NORMALLY CLOSED ELECTRICAL BOX SMOKE/COALARM QUICK DISCONNECTTYPE PLUG HOT / BLACK NEUTRAL / WHITE TANDEM WIREBRN / YEL SMOKE/COALARM ELECTRICAL BOX ELECTRICAL BOX SMOKE/COALARM G N -5 0 3 S E R I E S 551-0073-04Important Notice: These materials have been prepared by Gentex Corporation ("Gentex") for informational purposes only, are necessarily summary, and are not purported to serve as legal advice and should not be used as such. Gentex makes no representations and warranties, express or implied, that these materials are complete and accurate, up-to-date, or in compliance with all relevant local, state and federal laws, regu- lations and rules. The materials do not address all legal considerations as there is inevitable uncertainty regarding interpretation of laws, regulations and rules and the application of such laws, regulations and rules to particular fact patterns. Each person's activities can differently affect the obligations that exist under applicable laws, regulations or rules. Therefore, these materials should be used only for informational purposes and should not be used as a substitute for seeking professional legal advice. Gentex will not be responsible for any action or failure to act in reliance upon the information contained in this material. AArrcchhiitteecctt && EEnnggiinneeeerriinngg SSppeecciiffiiccaattiioonnss The combination photoelectric smoke and carbon monoxide alarm shall be a Gentex Model GN-503/GN-503F/GN-503FF or approved equal which shall provide at least the following features and functions: 1.Nominal smoke sensitivity shall be 2.5%. 2.The smoke alarm portion of device shall utilize an infrared LED sensing circuit which pulses in 4 to 5 second intervals when subjected to smoke. After 2 consecutive pulses in smoke, the alarm shall activate. 3.The CO alarm shall utilize an electrochemical sensing element with a minimum 5-year life. 4.The carbon monoxide alarm portion of device is adjusted not to detect CO levels below 30 PPM and will not alarm when exposed to constant levels of 30 PPM for 30 days. Per ANSI/UL 2034 requirements, the device will alarm at the following levels: 70 PPM CO between 1 to 4 hours, but not less than 1 hour. 150 PPM CO between 10 to 50 minutes. 400 PPM between 4 to 15 minutes. 5. The GN-503 Series device shall have a Duracelll®MN 1604 9VDC alkaline battery as a back-up in the event building power is lost. 6.The 9VDC battery impedance shall be verified by the circuit of the smoke/CO alarm. 7.The alarm shall provide an indicator when the battery is low in power, high impedance or is missing. 8.The CO alarm will provide an audible indicator of 3 quick chirps every 30 seconds at end of life of CO sensor. 9.The sensing chamber shall be fully protected to prevent entrance of small insects, thus reducing the probability of false alarms. 10.The alarm shall include a solid state red color LED that will indicate presence of CO at the unit. 11.The alarm shall include a solid state piezo alarm rated at 85dBA at 10ft. 12.A visual LED monitor (condition indicator) shall slow pulse in normal operation and rapid pulse in alarm (red color) 13.An easily accessible test button shall be provided. Push down on button for 5 seconds causing smoke/CO alarm to activate. If device does not go into alarm, the device is not working properly. 14.The device shall have tandem interconnect capability of up to 12 smoke/CO alarms. 15.The GN-503 and GN-503F alarm shall have the capability to tandem interconnect with all Gentex tandem capable smoke alarms, CO alarms or combination smoke/CO alarms, including 7000/7003 Series, 9000/9003 Series, 710CS/713CS Series, 7109CS/7139CS Series, GN-200/GN-300 Series, S1209 Series and CO1209 Series. 15.The GN-503FF alarm shall have the capability to tandem interconnect with the following Gentex alarms, CO alarms or combination smoke/CO alarms: GN-503 Series, S1209 Series and CO1209 Series. 16.The manufacturer shall provide models with the optional feature of auxiliary Form A/Form C relay contacts for initiating remote functions and annunciation and a relay option that is capable of activation by tandem interconnect wire. 17.The combination smoke/CO alarm shall be non-latching (self-restoring). 18.Unit must be ANSI/UL 217 and ANSI/UL 2034 listed for both wall and ceiling mounting. 19.Unit shall be listed by Underwriters Laboratories and California State Fire Marshal (CSFM). All equipment shall be completely factory assembled, wired and tested, and the contractor shall be prepared to submit a certified letter testifying to this condition. Alarms which do not meet all of the requirements of this specification will not be considered. For complete product specifications, refer to product installation manual. 24 units per carton 24 pounds per carton Electrical Specifications Operating Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .120VAC, 60Hz Operating Current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..045 amps Operating Current (Relay Options) . . . . . . . . . . . . . . . . . . . . . ..070 amps Operating Ambient Temp Range . . . . . . . . . . . . . . . . . . . . . . . .40°F to 100°F (4.4°C-38°C) Alarm Horn Rating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .85dBA at 10 feet (3.048 m) Auxiliary Relay (GN-503F) . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 Form A & 1 Form C (0.5 amp) Auxiliary Relay (GN-503FF) . . . . . . . . . . . . . . . . . . . . . . . . . . .2 Form A & 2 Form C (0.3 amp) Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Diameter at base: 5.75 in. (14.605 cm) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Overall diameter 6.25 in. (16.51 cm) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Depth: 1.8 in. (4.572 cm) Secondary Power Source . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Alkaline 9VDC battery (Duracell®MN 1604) CO Sensing Cell . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Electrochemical Cell