Loading...
HomeMy WebLinkAboutB12-0301 - CR1 - 092412 CUT SHEETSIBasement Window Wells: Sizes Of Basement Window Wells I Photo... 11 ROCK%VELL WINDOW WELLS HOME PRODUCTS DISTRIBUTORS zunrrmtrc _.- r nnrrarmrrc_ http://www.rockwellinc.com/windowWel]SizesA.htm] CZJESTIONS? CONTACT US Menu elite wells premier wells cascade wells ACCESSORIES covers grates ladders (optional) INFORMATION product features safety P. warranty builder resources literature Ll PREMIER SERIES RockWell window wells have a stone texture that truly looks and feels like real stone. Adding great curb appeal and an aesthetically pleasing view from the inside out. Our wells also allow for more light into an otherwise dark & drab basement. Patent US 7,966,776 L f Premier Series Item Isit) Projection Height Weight WPT- 663924* 66 39 24 35 WPT- 663936* 66 39 36 50 WPT- 663948 66 39 48 70 WPT- 663960 66 39 60 1 80 The24 "and36" heght Ketdo notcontan steps Note: All dimensions are in inches Flange widths are 4.5 inches Examples: WPT- 663948 =Well, Single Step, Tan, 66x39x48 WPG- 663960 =Well, Single Z!!! Grey, 39x60 I of 9/18/20129:11 AM Lon Basement Window Wells: Example Brown & Gray Basement Window Wells I Photos Page 1 of 1 RMKAVELI; - CONTACT USWINDOWWELLS HO'GE PRODUCTS DISTRIBUTORS RESOURCES GALLERY ABOUT U5 - - -- CONTACT US cj rp Its Menu P. elite wells premier wells cascade wells ACCESSORIES covers grates ladders (optional) INFORMATION product features safety warranty builder resources literature PRODUCT FEATURES True Texture Finally there is an alternative to unattractive window wells RockWell has duplicated in great detail the texture and color of real stone. These window wells and feel like real stone. / True Texture isavailable in Sandstone Tan and Limestone Grey. Durability Pea Gravel / Rock - NOT REQUIRED for Backfill High Strength - Will Not Collapse from Backfill UV stable and resistant to water, frost and extreme temperatures One -Piece Rigid composite construction Rust and rot proof IRC 2009 Compliant ammmizzw= Simple Installation Weighs less than steel window wells One piece unit, no assembly required Mounts to foundation wall with wedge anchors Safety With Rockwell's built -in step, you will have peace ofmind knowing that your family can escape from your basement in the event of an emergency. Escape steps provide emergency escape for family and fire and rescue personnel. Sandstone Tan 4. Limestone Gray I Copyright 2011 Rockwell Window Wells. All RightsReserved. NOME PRODUCTS GALLERY DISTRIBUTORS RESOURCES ABOUT US CONTACT USPatentedTechnology WINDOW WELLS EGRESS WINDOW WELLS BASEMENT WINDOWWELL BASEMENT EGRESS WINDOWWELLS http://www.rockwellinc.com/trueTexture.html 9/18/2012 Basement Window Wells: Emergency Escape Basement Window Wells 0 http://www.rockwellinc.com/EgressCode.htmi RocidAFELL I-5N A CONTACT UsWINDOWWELLS HOME IMF PRODUCTS DISTRIBUTORS RES URGES GALLERY ABOUT US CONTACT US y_ dF Menu IRC 2oo9 EGRESS CODE VVEI'LS Section R310 r elite wells EMERGENCY ESCAPE AND RESCUE OPENINGS premier wells R330.1 Emergency escape and rescue required. Basements with habitable space and every sleeping room shall have at least one operable emergency escape and rescue opening. Where basements contain one or more sleeping rooms, cascade wells emergency egress and rescue openings shall be required in each sleeping room, but shall not be required in adjoining areas of the basement. Where emergency and escape and rescue openings are provided they shall have a sill height of not more ACCESSORIES than 44 inches (1118 mm) above the floor. Where a door opening having a threshold below the adjacent ground elevation serves as an emergency escape and rescue opening and is provided with a bulkhead enclosure, the bulkhead enclosure shall covers comply with Section 310.3. The net clear opening dimensions required by this section shall be obtained by the normal operation of the emergency escape and rescue opening from the inside. Emergency escape and rescue openings with a grates finished sill height below the adjacent ground elevation shall be provided with a window well in accordance with Section R310.2. ladders (optional) R330.1.1 Minimum opening area. All emergency escape and rescue openings shall have a minimum net clear INFORMATION opening of 5 square feet (0.530 m2). product features Exception: Grade floor opening shall have a minimum net clear opening of 5 square feet (0.465 m2). safety R330.1.2 Minimum opening height. The minimum net clear opening height shall be 24 inches (610 mm). warranty R330.1.3 Minimum opening width. The minimum net clear opening width shall be 20 inches (508 mm). builder resources R330.1.4 Operational constraints. Emergency escape and rescue openings shall be operational from the inside of literature the room without the use of keys or tools. R330.2 Window wells. The minimum horizontal area of the window well shall be 9 square feet (0.84 m2), with a minimum horizontal projection and width of 36 inches (914 mm). The area of the window well shall allow the emergency escape and rescue opening to be fully opened. CONTACT US Exception: The ladder or steps required by Section R310.2.1 shall be permitted to encroach a maximum of 6 inches 152 mm) into the required dimensions of the window well. R310.2.1 Ladder and steps. Window wells with a vertical depth greater than 44 inches (1118 mm) shall be equipped with a permanently affixed ladder or steps usable with the window in the fully open position. Ladders or steps required by this section shall not be required to comply with the sections R311.5 and R311.6. Ladders or rungs shall have an inside width of at least 12 inches (305 mm), shall project at least 3 inches (76 mm) from the wall and shall be spaced not more than 18 inches (457 mm) on center vertically for the full height of the window well. R310.3 Bulkhead enclosures. Bulkhead enclosures shall provide direct access to the basement. The bulkhead enclosure with the door panels in the fully open position shall provide the minimum net clear opening required by Section R310.1.1. Bulkhead enclosures shall also comply with Section R311.5.8.2. R310.4 Bars, grills, covers and screens. Bars, grills, covers and screens or similar devices are permitted to be placed over emergency escape and rescue openings, bulkhead enclosures, or window wells that serve such openings, provided the minimum net clear opening size complies with Sections R310.1.1 to R310.1.3, and such devices shall be releasable or removable from the inside without the use of a key, tool or force greater than that which is required for normal operation of the escape and rescue opening. Copyrght 2011 RockWel Window Wets. All Rghts Reserved. HOME PRODUCTS GALLERY DISTRIBUTORS RESOURCES ABOUT US CONTACT US Patented Technology WINDOW WELLS EGRESS WINDOW WELLS BASEMENT WINDOW WELL BASEMENT EGRESS WINDOW WELLS 1 of 1 9/18/2012 9:10 AM IBasement Window Wells: Polycarbonate Basement Window Wells C... ItMILIWLI; WINDOW WELLS HOME PRODUCTS DISTRIBUTORS anntr rtc rnsrmnnm nc http:// www .rockwellinc.com /ladders.htmi CONTACT US Building Materials Roof Siding Other Wall Materials Fascia Soffits Windows Window Trim Doors Door Trim Hand or Deck Rails Flues Flashing Chimneys Trash Enclosures Greenhouses Retaining Walls Exterior Lighting Oth_er_ PROPOSED MATERIALS Type of Material Notes: Please specify the manufacturer's name, the color name and number and attach a color chip. Color L t ryti.. .!•x'•1;.5: .. .. ry. Project Number: U1080- 001 -081 August 29, 2008 Rockwell, Inc. 55 East 600 South Provo, UT 84606 ATTENTION: Mr. Vaughn Cook REFERENCE: ROCKWELL FIBERGLASS WINDOW WELL RISA 3D ANALYSIS OF 8' -6" TALL WINDOW WELL Mr. Cook: Per your request, we have created a computer model of the Rockwell Window Well using RISA 31). Using the RISA 3D computer model, we have analyzed the Rockwell Fiberglass Window Well to determine if the window well can support lateral earth pressures up to 62poundspercubicfoot (pco. The following criteria was used in the analysis: 1. Window well dimensions = 66 inches wide x 44 inches deep x 102 inches high. See sheets 5 thin 7 in the structural calculations for actual shape and dimensions of window well. 2. Wall connection = Minimum of eight (8) anchors at each flange on each side of window well. Anchors to be spaced a maximum of 18 inches on center. Fiberglass material properties: Flexural Yielding Stress = 35,064 psi Flexural Modulus = 1,516,000 psi Shear Yielding Stress = 48,555 psi Compression Yielding Stress = 15,189 psi Tension Yielding Stress = 13,747 psi Coefficient of Thermal Expansion = 0.000015 in/in/ °F Based on our computer analysis using RISA 31), the above referenced Rockwell Fiberglass Window Well can support lateral soil pressures up to 62 pcf. See the structural calculations prepared by our office) dated August 29, 2008 for supporting calculations and additional information. We hope this meets your needs. If you have any fiuther questions regarding this matter, please contact this office at your convenience. Sincerely, L. R. NELS, ULTING ENGINEERS, LLC 0OFES SlO G G) w 0.3 127 ZUm sT TFOFV P Brett D. Young, P.E., S.E. Managing Engineer BDY/bdy