RockWell window wells have a stone texture that truly looks and feels like real stone. Adding great curb appeal and an
aesthetically pleasing view from the inside out. Our wells also allow for more light into an otherwise dark & drab basement.
Patent US 7,966,776
L f
Premier Series
Item Isit) Projection Height Weight
WPT- 663924* 66 39 24 35
WPT- 663936* 66 39 36 50
WPT- 663948 66 39 48 70
WPT- 663960 66 39 60 1 80
The24 "and36" heght Ketdo notcontan steps
Note:
All dimensions are in inches
Flange widths are 4.5 inches
Examples:
WPT- 663948 =Well, Single Step, Tan, 66x39x48
WPG- 663960 =Well, Single Z!!! Grey, 39x60
I of 9/18/20129:11 AM
Lon
Basement Window Wells: Example Brown & Gray Basement Window Wells I Photos Page 1 of 1
RMKAVELI; - CONTACT USWINDOWWELLS
HO'GE PRODUCTS DISTRIBUTORS RESOURCES GALLERY ABOUT U5 - - --
CONTACT US
cj rp
Its Menu
P. elite wells
premier wells
cascade wells
ACCESSORIES
covers
grates
ladders (optional)
INFORMATION
product features
safety
warranty
builder resources
literature
PRODUCT FEATURES
True Texture
Finally there is an alternative to unattractive window wells
RockWell has duplicated in great detail the texture and color of real stone. These window wells
and feel like real stone. /
True Texture isavailable in Sandstone Tan and Limestone Grey.
Durability
Pea Gravel / Rock - NOT REQUIRED for Backfill
High Strength - Will Not Collapse from Backfill
UV stable and resistant to water, frost and extreme temperatures
One -Piece Rigid composite construction
Rust and rot proof
IRC 2009 Compliant
ammmizzw=
Simple Installation
Weighs less than steel window wells
One piece unit, no assembly required
Mounts to foundation wall with wedge anchors
Safety
With Rockwell's built -in step, you will have peace ofmind knowing that your
family can escape from your basement in the event of an emergency. Escape
steps provide emergency escape for family and fire and rescue personnel.
Sandstone Tan
4.
Limestone Gray
I
Copyright 2011 Rockwell Window Wells. All RightsReserved. NOME PRODUCTS GALLERY DISTRIBUTORS RESOURCES ABOUT US CONTACT USPatentedTechnology
WINDOW WELLS EGRESS WINDOW WELLS BASEMENT WINDOWWELL BASEMENT EGRESS WINDOWWELLS
http://www.rockwellinc.com/trueTexture.html 9/18/2012
Basement Window Wells: Emergency Escape Basement Window Wells
0
http://www.rockwellinc.com/EgressCode.htmi
RocidAFELL I-5N A CONTACT UsWINDOWWELLS
HOME
IMF
PRODUCTS DISTRIBUTORS RES URGES GALLERY
ABOUT US CONTACT US y_
dF Menu IRC 2oo9 EGRESS CODE
VVEI'LS Section R310
r elite wells
EMERGENCY ESCAPE AND RESCUE OPENINGS
premier wells R330.1 Emergency escape and rescue required. Basements with habitable space and every sleeping room shall have
at least one operable emergency escape and rescue opening. Where basements contain one or more sleeping rooms,
cascade wells emergency egress and rescue openings shall be required in each sleeping room, but shall not be required in adjoining areas
of the basement. Where emergency and escape and rescue openings are provided they shall have a sill height of not more
ACCESSORIES than 44 inches (1118 mm) above the floor. Where a door opening having a threshold below the adjacent ground elevation
serves as an emergency escape and rescue opening and is provided with a bulkhead enclosure, the bulkhead enclosure shall
covers comply with Section 310.3. The net clear opening dimensions required by this section shall be obtained by the normal
operation of the emergency escape and rescue opening from the inside. Emergency escape and rescue openings with a
grates finished sill height below the adjacent ground elevation shall be provided with a window well in accordance with Section
R310.2.
ladders (optional)
R330.1.1 Minimum opening area. All emergency escape and rescue openings shall have a minimum net clear
INFORMATION opening of 5 square feet (0.530 m2).
product features Exception: Grade floor opening shall have a minimum net clear opening of 5 square feet (0.465 m2).
safety R330.1.2 Minimum opening height. The minimum net clear opening height shall be 24 inches (610 mm).
warranty R330.1.3 Minimum opening width. The minimum net clear opening width shall be 20 inches (508 mm).
builder resources
R330.1.4 Operational constraints. Emergency escape and rescue openings shall be operational from the inside of
literature the room without the use of keys or tools.
R330.2 Window wells. The minimum horizontal area of the window well shall be 9 square feet (0.84 m2), with a
minimum horizontal projection and width of 36 inches (914 mm). The area of the window well shall allow the emergency
escape and rescue opening to be fully opened.
CONTACT US Exception: The ladder or steps required by Section R310.2.1 shall be permitted to encroach a maximum of 6 inches
152 mm) into the required dimensions of the window well.
R310.2.1 Ladder and steps. Window wells with a vertical depth greater than 44 inches (1118 mm) shall be equipped
with a permanently affixed ladder or steps usable with the window in the fully open position. Ladders or steps required
by this section shall not be required to comply with the sections R311.5 and R311.6. Ladders or rungs shall have an
inside width of at least 12 inches (305 mm), shall project at least 3 inches (76 mm) from the wall and shall be spaced
not more than 18 inches (457 mm) on center vertically for the full height of the window well.
R310.3 Bulkhead enclosures. Bulkhead enclosures shall provide direct access to the basement. The bulkhead
enclosure with the door panels in the fully open position shall provide the minimum net clear opening required by
Section R310.1.1. Bulkhead enclosures shall also comply with Section R311.5.8.2.
R310.4 Bars, grills, covers and screens. Bars, grills, covers and screens or similar devices are permitted to be
placed over emergency escape and rescue openings, bulkhead enclosures, or window wells that serve such openings,
provided the minimum net clear opening size complies with Sections R310.1.1 to R310.1.3, and such devices shall be
releasable or removable from the inside without the use of a key, tool or force greater than that which is required for
normal operation of the escape and rescue opening.
Copyrght 2011 RockWel Window Wets. All Rghts Reserved. HOME PRODUCTS GALLERY DISTRIBUTORS RESOURCES ABOUT US CONTACT US
Patented Technology
WINDOW WELLS EGRESS WINDOW WELLS BASEMENT WINDOW WELL BASEMENT EGRESS WINDOW WELLS
1 of 1 9/18/2012 9:10 AM
IBasement Window Wells: Polycarbonate Basement Window Wells C...
ItMILIWLI;
WINDOW WELLS
HOME PRODUCTS DISTRIBUTORS
anntr rtc rnsrmnnm nc
http:// www .rockwellinc.com /ladders.htmi
CONTACT US
Building Materials
Roof
Siding
Other Wall Materials
Fascia
Soffits
Windows
Window Trim
Doors
Door Trim
Hand or Deck Rails
Flues
Flashing
Chimneys
Trash Enclosures
Greenhouses
Retaining Walls
Exterior Lighting
Oth_er_
PROPOSED MATERIALS
Type of Material
Notes:
Please specify the manufacturer's name, the color name and number and attach a color chip.
Color
L
t ryti.. .!•x'•1;.5: .. ..
ry.
Project Number: U1080- 001 -081
August 29, 2008
Rockwell, Inc.
55 East 600 South
Provo, UT 84606
ATTENTION: Mr. Vaughn Cook
REFERENCE: ROCKWELL FIBERGLASS WINDOW WELL
RISA 3D ANALYSIS OF 8' -6" TALL WINDOW WELL
Mr. Cook:
Per your request, we have created a computer model of the Rockwell Window Well using
RISA 31). Using the RISA 3D computer model, we have analyzed the Rockwell Fiberglass
Window Well to determine if the window well can support lateral earth pressures up to 62poundspercubicfoot (pco. The following criteria was used in the analysis:
1. Window well dimensions = 66 inches wide x 44 inches deep x 102 inches
high. See sheets 5 thin 7 in the structural calculations for actual shape
and dimensions of window well.
2. Wall connection = Minimum of eight (8) anchors at each flange on each
side of window well. Anchors to be spaced a maximum of 18 inches on
center.
Fiberglass material properties:
Flexural Yielding Stress = 35,064 psi
Flexural Modulus = 1,516,000 psi
Shear Yielding Stress = 48,555 psi
Compression Yielding Stress = 15,189 psi
Tension Yielding Stress = 13,747 psi
Coefficient of Thermal Expansion = 0.000015 in/in/ °F
Based on our computer analysis using RISA 31), the above referenced Rockwell Fiberglass
Window Well can support lateral soil pressures up to 62 pcf. See the structural calculations
prepared by our office) dated August 29, 2008 for supporting calculations and additional
information.
We hope this meets your needs. If you have any fiuther questions regarding this matter,
please contact this office at your convenience.
Sincerely,
L. R. NELS, ULTING ENGINEERS, LLC
0OFES SlO
G G) w 0.3 127 ZUm
sT TFOFV P
Brett D. Young, P.E., S.E.
Managing Engineer