Loading...
HomeMy WebLinkAboutB12-0210 - REV1 - PLANS approvedTRANSMITTAL FORM Project Street Address: __________ ______________________________ ___________ (Number) (Street) (Suite #) Building/Complex Name: ________________________________ Building Permits: Revised ADDITIONAL Valuations (Labor & Materials) (DO NOT include original valuation) Building: $_____________________ Plumbing: $_____________________ Electrical: $_____________________ Mechanical: $_____________________ Total: $_____________________ Description of Transmittal/ List of Changes, Items Attached: __________________________________________________ __________________________________________________ __________________________________________________ __________________________________________________ __________________________________________________ __________________________________________________ (use additional sheet if necessary) Application/Permit #(s) information applies to: Attention: ( ) Revisions ( ) Response to Correction Letter ____________________________________ __________________________ ___attached copy of correction letter ( ) Deferred Submittal ____________________________________ __________________________ ( ) Other Use this form when submitting additional information for planning applications or building permits. This form is also used for requesting a revision to building permits. A two hour minimum building review fee of $110 will be charged upon reissuance of the permit. Date Received: Department of Community Development 75 South Frontage Road Vail, CO 81657 Tel: 970.479.2128 www.vailgov.com Development Review Coordinator For Office Use Only: Fee Paid: Received From: Cash _____ ____ Check # __ _ _______ CC: Visa / MC Last 4 CC # exp. date: Authorization # Applicant Information (architect, contractor, owner/owner’s rep) Contact Name: ________________________________________ Address: City _____________________ State: _______ Zip: ____________ Contact Name: _________________________________________ Contact Phone: _________________________________________ Contact E-Mail: _________________________________________ I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the town's zoning and subdivision codes, design review ap- proved, International Building and Residential Codes and other ordinances of the Town applicable thereto. X___________________________________________________ Owner/Owner’s Representative Signature (Required) Receptacles added in bedrooms 2011 NEC note added Electrical Load Calculations attached By David Rhoades at 1:47 pm, Sep 19, 2012 GFI 3 T TV TV 3 3 TT GF I TT 3 4 4 1 4 3 A B C D E 2 DECK 1 KITCHEN STAIR ENTRY BATH 1 BEDROOM 1 CL 3 BU I L T - I N S T O R A G E TV PANTRY D/W W/D ELEC. P DINING ROOMLIVING ROOM REF. RELOCATE RELOCATE RELOCATE RELOCATE RELOCATE RELOCATE RELOCATE RELOCATE RELOCATE C C D S NEW ELECTRIC RADIENT FLOOR HEATING MAT UNDER TILE CFL RELOCATE RELOCATE FAN ONLY RELOCATE C C C RELOCATE RELOCATEC C RELOCATE UNDER CAB. LIGHTS220 RELOCATE RELOCATE TO J-BOX ABOVE SC A L E PR O J E C T N U M B E R DR A W N B Y CH E C K E D B Y CO P Y R I G H T 2 0 1 2 1D R C P R E L I M . R E V I E W 0 5 . 1 2 . 1 1 2B I D S E T 0 6 . 1 5 . 1 1 3T . O . V . P E R M I T S E T 0 5 . 2 4 . 1 2 4T . O . V . I N T . P E R M I T S E T 0 8 . 3 0 . 1 2 5P E R M I T C O M M E N T S R E V . 0 9 . 1 9 . 1 2 As i n d i c a t e d 14 7 6 W E S T H A V E N D R . U N I T # 3 (C O L D S T R E A M ) V A I L , C O 8 1 6 5 7 PA R C E L # 2 1 0 3 1 2 1 0 8 0 0 3 AC C O U N T # R 0 1 3 0 6 8 A2 . 0 4 SE C O N D F L O O R LI G H T I N G & E L E C T R I C A L PL A N 06 1 1 KO E L B E L RE S I D E N C E IN T E R I O R AL T E R A T I O N Au t h o r Ch e c k e r T. O . V . I N T E R I O R PE R M I T S U B M I T T A L 08 . 3 0 . 1 2 1/4" = 1'-0"1 SECOND FLOOR LIGHTING & ELECTRICAL PLAN GENERAL NOTES: 1.ONLY NEW & RELOCATED ELECTRICAL FIXTURES (LIGHTING, SWITCHING, OUTLETS, CABLE, CAT5, TELEPHONE, THERMOSTAT & HEAT REGISTERS) ARE SHOWN. 2.RELOCATED EXISTING ELECTRICAL FIXTURES ARE NOTED. 3.EXISTING ELECTRICAL FIXTURES ON DEMO WALLS THAT ARE NOT RELOCATED ARE TO BE ABANDONED. 4.REMOVE ALL HUMIDIFICATION UNITS & THEIR CONTROLS. 5.ALL EXISTING HEAT REGISTERS ARE TO BE REPLACED W/ NEW HEAT REGISTERS OF THE SAME HEATING CAPACITY. 6.INSTALL PER 2011 NEC. NO . D E S C R I P T I O N D A T E By David Rhoades at 1:48 pm, Sep 19, 2012 Reviewed for Code Compliance Code: 2009 International Building Code (IBC) By Martin Haeberle at 8:32 am, Oct 04, 2012 T 3 TV 3GFI 3GFI TV T T T 4 4 4 J 1 4 3 A B C D E 2 STAIR DECK 2 OPEN TO BELOW OFFICE BENCH MASTER BATH MASTER BEDROOM S RELOCATE RELOCATE RELOCATE RELOCATE RELOCATE RELOCATE C RELOCATE C NEW ELECTRICRADIENT FLOORHEATING MATUNDER TILE RELOCATE RELOCATE FAN ONLY CFL TO SWITCH BELOW SCALE PROJECT NUMBER DRAWN BY CHECKED BYCOPYRIGHT 2012 1 DRC PRELIM. REVIEW 05.12.11 2 BID SET 06.15.11 3 T.O.V. PERMIT SET 05.24.12 4 T.O.V. INT. PERMIT SET 08.30.12 5 PERMIT COMMENTS REV. 09.19.12 As indicated 1476 WESTHAVEN DR. UNIT #3 (COLDSTREAM) VAIL, CO 81657 PARCEL #210312108003 ACCOUNT #R013068 A2.05 THIRD FLOOR LIGHTING & ELECTRICAL PLAN 0611 KO E L B E L RE S I D E N C E IN T E R I O R AL T E R A T I O N Author Checker T.O.V. INTERIOR PERMIT SUBMITTAL 08.30.12 1/4" = 1'-0"1 THIRD FLOOR LIGHTING & ELECTRICAL PLAN GENERAL NOTES: 1.ONLY NEW & RELOCATED ELECTRICAL FIXTURES (LIGHTING, SWITCHING, OUTLETS, CABLE, CAT5, TELEPHONE, THERMOSTAT & HEAT REGISTERS) ARE SHOWN. 2.RELOCATED EXISTING ELECTRICAL FIXTURES ARE NOTED. 3.EXISTING ELECTRICAL FIXTURES ON DEMO WALLS THAT ARE NOT RELOCATED ARE TO BE ABANDONED. 4.REMOVE ALL HUMIDIFICATION UNITS & THEIR CONTROLS. 5.ALL EXISTING HEAT REGISTERS ARE TO BE REPLACED W/ NEW HEAT REGISTERS OF THE SAME HEATING CAPACITY. 6.INSTALL PER 2011 NEC. NO. DESCRIPTION DATE By David Rhoades at 1:47 pm, Sep 19, 2012 Reviewed for Code Compliance Code: 2009 International Building Code (IBC) By Martin Haeberle at 8:32 am, Oct 04, 2012 !!!!!!!!!!!!!!!!!!!French!Electric,!Inc.! !!!!!!Po!box!3638!eagle,!co.81631!!!!!!!!!!!!!!!!!!!!!!!!Lic.!3595!!!!!!!!!!!!!!!!!!!!!!!!!!!phone!number!!!970=471=0707! !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!Email:frenchelectric22@gmail.com! ! ! !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!Koelbel!Remodel!Load!Calculations! !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!1476!Westhaven!Dr.!unit!#3!! ! ! !!!!!!!!!!!!!!!!!!!!!!!!!General!lighting:!!!1450!sq/ft!!@!3va!=!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!4350!va! !!!!!!!!!!!!!!!!!!!!!!!!!2=!Small!appliance!circuits!@1500va!=!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!3000!va! !!!!!!!!!!!!!!!!!!!!!!!!!Stacked!washer/dryer!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!5000!va! !!!!!!!!!!!!!!!!!!!!!!!!!Range!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!12000!va! !!!!!!!!!!!!!!!!!!!!!!!!!Water!heater!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!5000!va! !!!!!!!!!!!!!!!!!!!!!!!!!Dishwasher!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!1200!va! !!!!!!!!!!!!!!!!!!!!!!!!!Garbage!disposal!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!750!va! !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!31300!va! ! !!!!!!!!!!!!!!!!!!!!!!!!!First!10!kva!@!100%!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!10000!va! !!!!!!!!!!!!!!!!!!!!!!!!!Remainder!!@!!!40%!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!21300!x!0.4!=!!8520!va! !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!________! !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!18520!va! !!!!!!!!!!!!!!!!!!!!!!!!!Electric!heat!@!!40%!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!10150!x!0.4!=!!4060!va! !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!22580!va! ! !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!22580!va!/!240!v!=!91.4!amps! ! !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!Minimum!feeder/service!is!!100!amps! By David Rhoades at 1:48 pm, Sep 19, 2012