HomeMy WebLinkAboutB12-0535 LOAD CALCSA-Phase Electric, LLC Load Calculation Lodge at Vail Unit #635
General Lighting and Receptacle Demand Load:
1622 sq. ft. x3VA= 4866 220.3(a) 1,500 VA X 2= 3000 220.16(a) 1,500 VA X 1 = 1500 220.16(b) Total connected load: 9,366
3,000 VA @ 100% = 3,000 220.11 VA@35%= 2,228.1 779.835 Total general lighting and Receptacle demand load: 3,780
Range demand load:
12,000VA 8,000 220.19
Dryer Load:
5,000 220.18
Fixed appliance load:
Dishwasher 1.2 kva 1 1,200 Garbage disposal .8 kva 1 800 Sub-Zero 1.2 kva 0 0 Steam shower 9.6 kva 0 0 Hot tub 12 kva 0 0
Total fixed appliance load: 2,000
A-Phase Electric, LLC Load Calculation Lodge at Vail Unit #635
Heating load:
Boiler 0.2 0 0 Pump 0.2 0 0 Baseboard heat .25/ft 0 0 Wall heater 1,500 0 0
Total heating load: 0
25% of largest motor: 1,200
Totals:
General lighting and receptacles: 3,780 Range: 8,000 Dryer: 5,000 Fixed appliance: 2,000 Heating: 0 25% of largest motor: 1,200
Total: VA 19,980
AMPS 83.25
Installed Service Size: Secondary Conductors: Distance from vault to meter:
150A single phase 120/240 2/0 Aluminum 150'
A-Phase Electric, LLC Load Calculation Lodge at Vail Unit #640
General Lighting and Receptacle Demand Load:
1490 sq. ft. x3VA= 4470 220.3(a) 1,500 VA X 2= 3000 220.16(a) 1,500 VA X 1 = 1500 220.16(b) Total connected load: 8,970
3,000 VA @ 100% = 3,000 220.11 VA @ 35% = 2,089.5 731.325 Total general lighting and Receptacle demand load: 3,731
Range demand load:
12,000VA 8,000 220.19
Dryer Load:
5,000 220.18
Fixed appliance load:
Dishwasher 1.2 kva 1 1,200 Garbage disposal .8 kva 1 800 Sub-Zero 1.2 kva 0 0 Steam shower 9.6 kva 0 0 Hot tub 12 kva 0 0
Total fixed appliance load: 2,000
A-Phase Electric, LLC Load Calculation Lodge at Vail Unit #640
Heating load:
Boiler 0.2 0 0 Pump 0.2 0 0 Baseboard heat .25/ft 0 0 Wall heater 1,500 0 0
Total heating load: 0
25% of largest motor: 1,200
Totals:
General lighting and receptacles: 3,731 Range: 8,000 Dryer: 5,000 Fixed appliance: 2,000 Heating: 0 25% of largest motor: 1,200
Total: VA 19,931
AMPS 83.05
Installed Service Size: Secondary Conductors: Distance from vault to meter:
150A single phase 120/240 2/0 Aluminum 150'