HomeMy WebLinkAboutB12-0535 LOAD CALCSA-Phase Electric, LLC Load Calculation Lodge at Vail Unit #635 General Lighting and Receptacle Demand Load: 1622 sq. ft. x3VA= 4866 220.3(a) 1,500 VA X 2= 3000 220.16(a) 1,500 VA X 1 = 1500 220.16(b) Total connected load: 9,366 3,000 VA @ 100% = 3,000 220.11 VA@35%= 2,228.1 779.835 Total general lighting and Receptacle demand load: 3,780 Range demand load: 12,000VA 8,000 220.19 Dryer Load: 5,000 220.18 Fixed appliance load: Dishwasher 1.2 kva 1 1,200 Garbage disposal .8 kva 1 800 Sub-Zero 1.2 kva 0 0 Steam shower 9.6 kva 0 0 Hot tub 12 kva 0 0 Total fixed appliance load: 2,000 A-Phase Electric, LLC Load Calculation Lodge at Vail Unit #635 Heating load: Boiler 0.2 0 0 Pump 0.2 0 0 Baseboard heat .25/ft 0 0 Wall heater 1,500 0 0 Total heating load: 0 25% of largest motor: 1,200 Totals: General lighting and receptacles: 3,780 Range: 8,000 Dryer: 5,000 Fixed appliance: 2,000 Heating: 0 25% of largest motor: 1,200 Total: VA 19,980 AMPS 83.25 Installed Service Size: Secondary Conductors: Distance from vault to meter: 150A single phase 120/240 2/0 Aluminum 150' A-Phase Electric, LLC Load Calculation Lodge at Vail Unit #640 General Lighting and Receptacle Demand Load: 1490 sq. ft. x3VA= 4470 220.3(a) 1,500 VA X 2= 3000 220.16(a) 1,500 VA X 1 = 1500 220.16(b) Total connected load: 8,970 3,000 VA @ 100% = 3,000 220.11 VA @ 35% = 2,089.5 731.325 Total general lighting and Receptacle demand load: 3,731 Range demand load: 12,000VA 8,000 220.19 Dryer Load: 5,000 220.18 Fixed appliance load: Dishwasher 1.2 kva 1 1,200 Garbage disposal .8 kva 1 800 Sub-Zero 1.2 kva 0 0 Steam shower 9.6 kva 0 0 Hot tub 12 kva 0 0 Total fixed appliance load: 2,000 A-Phase Electric, LLC Load Calculation Lodge at Vail Unit #640 Heating load: Boiler 0.2 0 0 Pump 0.2 0 0 Baseboard heat .25/ft 0 0 Wall heater 1,500 0 0 Total heating load: 0 25% of largest motor: 1,200 Totals: General lighting and receptacles: 3,731 Range: 8,000 Dryer: 5,000 Fixed appliance: 2,000 Heating: 0 25% of largest motor: 1,200 Total: VA 19,931 AMPS 83.05 Installed Service Size: Secondary Conductors: Distance from vault to meter: 150A single phase 120/240 2/0 Aluminum 150'