HomeMy WebLinkAboutB12-0507 ASBESTOS REPORT11-27-2012 Inspection Request Reporting Page 13
4�04 pm VaiI,SO - Citv �f
Requested Inspect Date: Wednesday, November 28, 2012
Site Address: 1030 LIONS RIDGE LOOP VAIL
SNOW FOX UNIT 202
A/P/D Information
Activity: B12-0507 Type: COMBO Sub Type: AMF
Const Type: Occupancy: Use: R-2
Owner: STENGER, MARY JANET A. & ALAN J.
Contractor: STENGER CONTRACTING Phone: 720-287-1994
Description: INTERIOR REMODEL
Requested Inspection(s)
Item: 290 PLMB-Final
Requestor: STENGER CONTRACTING
Status: ISSUED
Insp Area:
Requested Time: 04:30 PM
Phone: 720-287-1994
Comments: 390-6145
Assigned To: JMONDRAGON Entered
Action: Time Exp:
Inspection Historv
Item: 120 ELEC-Rough
10/30/1Z Inspector:
Comment:
Item: 220 PLMB-Rough/D.W.V.
10/18/1Z Inspector:
Comment:
Item: 230 PLMB-Rough/Water
10/18/1Z Inspector:
Comment:
Item: 30 BLDG-Framing
10/30/12 Inspector:
Comment:
Item: 50 BLDG-Insulation
Item: 60 BLDG-Sheetrock Nail
10/30/12 Inspector:
Comment: Dura rock
11 /02/12 Inspector:
Comment:
Item: 190 ELEC-Final
Item: 290 PLMB-Final
Item: 90 BLDG-Final
�
'" Approved *'
sgremmer
** Approved '"
sgremmer
*' Approved *'`
sgremmer
"" Approved *�
sgremmer
'" Approved '"
sgremmer
JRM
Action: AP APPROVED
Action: AP APPROVED
Action: AP APPROVED
Action: AP APPROVED
By: JMONDRAGON K
Action: PI PARTIAL INSPECTION
Action: AP APPROVED
REPT131 Run Id: 14626
Presented To:
Mr. Alan Stenger
Homeowner
3�a_oso7
.
onsu In
Background Air Sampling Report
1030 Lions Ridge Loop, Vail, Colorado 81657
Performed & Prepared By:
Mr. Steve Shurtliff
DS Consulting, Inc.
PO Box 6864
Avon,CO 81620
(303) 378-1544
Project Details:
Project Number: 6420
Conducted: September 19, 2012
Snow Fox - Unit 202
TABLE OF CONTENTS
PROJECT OVERVIEW
1.0 Introduction
2.0 Scope of Work
3.0 Site Description
4.0 Certifications
5.0 Inspection, Sampling & Analytical Procedures
6.0 Overview of Findings
7.0 Conclusion & Recommendations
8.0 Disclaimer & Limitations
2
PROJECT OVERVIEW
1.0 Introduction
On September 19, 2012, Mr. Steve Shurtliff of DS Consulting, Inc. (DSC) performed a limited background
air sampling within the utility closet and associated hallway of the single-family residence located at
1030 Lions Ridge Loop, Unit 202, Vail, Colorado in which a recent, non-permitted asbestos abetment
project was conducted to remove approximately six square feet of asbestos-containing vinyl flooring.
The purpose of the background air sampling was to determine if the Maximum Allowable Asbestos Level
(MAAL) of 0.01 fibers/cc was exceeded utilizing Phase Contrast Microscopy (PCM), which is not specific
to asbestos fibers, but counts all criteria fulfilling fibers in order to show no asbestos contamination was
present within the air following the abatement.
2.0 Scope of Work
The background air sampling was limited to the utility closet in which the asbestos-containing flooring
was removed as well as the associated hallway outside of it. The remaining areas within the residence,
garage or any out-building on the property were not included in the scope of the inspection.
3.0 Site Description
The residence is a wood-framed, single-level, single-family residence one the second level of a multi-unit
building of similarly constructed units.
4.0 Certifications
The limited background air sampling was conducted by Mr. Steve Shurtliff with DSC. DSC is a Colorado
Department of Public Health and Environment (CDPHE) certified Asbestos Consulting Firm, Registration
No. 14912. Mr. Shurtliff is a CDPHE certified Air Monitoring Specialist; having certification number
15413 (seeAppendixAforcertificates).
5.0 Inspection, Sampling & Analytical Procedures
The limited background air sampling and the PCM air sample analyzation were conducted by Mr. Steve
Shurtliff with DSC. Mr. Shurtliff is a CDPHE certified Air Monitoring Specialist (AMS); having certification
number 15413 and a NIOSH 582 certified analyst. DSC is a CDPHE certified Asbestos Consulting Firm,
Registration No. 14912 and a participant in the Industrial Hygiene Proficiency Analytical Testing (IHPAT)
program with laboratory ID No. 188987 maintaining a rating of Proficient.
6.0 Overview of Findings
DSC collected two background air samples from the residence. Neither sample exceeded the MAAL
following PCM analysis.
BRL - Below Reporting Limit
7.0 Conclusion & Recommendations
The MAAL was not exceeded following the background air sampling collected within the residence;
therefore, no professional abatement activities are required to clean the area.
8.0 Disclaimer & Limitations
The activities outlined in this report were conducted in a manner consistent with a level of care and
expertise exercised by members of the environmental consulting and industrial hygiene profession. All
activities were performed in accordance with all applicable federal, state, and local regulations as well as
generally accepted standards and professional practice. No warranty is either expressed or implied. DSC
assumes no responsibility or liability for error in public information utilized, statements from sources
other than DSC, or developments resulting from situations outside the scope of this project.
The details provided within this report outline the inspection activities on the date(s) indicated and
should not be relied upon to represent conditions at a later date. The laboratory results contained in this
report apply specifically to the samples collected. The results do not include or apply to any other
materials within the structure that were not sampled, but may contain asbestos; including
materials/areas that may be hidden or inaccessible. Additional inspection and bulk-sampling activities
would be required to determine if any other materials contain asbestos.
This report has been prepared on behalf of and exclusively for use by the Client, with specific application
to their project as discussed in the scope of work. The information contained in this report is intended as
supplementary material for abatement design and is not to be used as the scope of work for abatement
activities, bidding or billing purposes. Contractors or consultants reviewing this report must draw their
own conclusions regarding further investigation or remediation deemed necessary. DSC can provide a
full scope of work for abatement upon request. DSC does not warrant the work of regulatory agencies,
laboratories or other third parties supplying information which may have been used in the preparation of