Loading...
HomeMy WebLinkAboutF12-0076 Hydraulic Calculations SignedCentral Fire Protection 10775 E. 51st Ave. Denver, Colorado 80239 (303) 576-8157 Job Name:Casa Colorado Building:1042 Eagles Nest Circle Vail‚ Colorado Location:Third Floor Bedroom 305 System:Calc #1 Contract:290712 Data File:Casa Colorado Third Floor Bedroom 305 Calc #1.WX1 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Central Fire Protection Page1 Casa Colorado Date10-06-12 HYDRAULIC DESIGN INFORMATION SHEET Name - Casa Colorado Date - 10-06-2012 Location - Third Floor Bedroom 305 Building - 1042 Eagles Nest Circle Vail‚ Colorado System No. - Calc #1 Contractor - Central Fire Protection Contractors Inc Contract No. - 290712 Calculated By - Stephanie Pelster Drawing No. - FP2 Construction: (X) Combustible ( ) Non-Combustible Ceiling Height 8'-1" OCCUPANCY - NFPA 13D Residential S Type of Calculation: ( )NFPA 13 Residential ( )NFPA 13R (X)NFPA 13D Y Number of Sprinklers Flowing: ( )1 (X)2 ( )4 ( ) S ( )Other T ( )Specific Ruling Made by Date E M Listed Flow at Start Point - 23 Gpm System Type Listed Pres. at Start Point - 27.3 Psi (X) Wet ( ) Dry D MAXIMUM LISTED SPACING 18 x 18 ( ) Deluge ( ) PreAction E Domestic Flow Added - N/A Gpm Sprinkler or Nozzle S Additional Flow Added - N/A Gpm Make TYCO Model LF11 HSW I Elevation at Highest Outlet - Feet Size 1/2" K-Factor 4.4 G Note: Temperature Rating 155 N Calculation Gpm Required 47.04 Psi Required 73.172 At Pump Outlet Summary C-Factor Used: Overhead 150 Underground 150 W Water Flow Test: Pump Data: Tank or Reservoir: A Date of Test - 10-01-2012 Rated Cap. 50 Cap. T Time of Test - 10:00 AM @ Psi 41.6 Elev. E Static (Psi) - 100 Elev. 1' R Residual (Psi) - 95 Other Well Flow (Gpm) - 1318 Proof Flow Gpm S Elevation - 2' P Location: 1042 Eagles Nest Circle Vail‚ Colorado 81657 P L Source of Information: Test conducted by Central Fire Protection Contractors Y and witnessed by Vail Fire & Upper Eagle Valley Fire Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Ce n t r a l F i r e P r o t e c t i o n Page2 Ca s a C o l o r a d o Date10-06-12 12243648 E 60 R 72 U 84 S 96 S 10 8 E 12 0 R 13 2 P 14 4 15 6 16 8 18 0 20 0 4 0 0 6 0 0 8 0 0 1 0 0 0 1 2 0 0 1 4 0 0 1 6 0 0 1 8 0 0 FL O W ( N ^ 1 . 8 5 ) Ci t y W a t e r S u p p l y : P u m p D a t a : D e m a n d : C1 C2 C1 - S t a t i c P r e s s u r e : 9 0 C2 - R e s i d u a l P r e s s u r e : 8 5 . 5 C2 - R e s i d u a l F l o w : 1 3 1 8 A1 Ci t y W a t e r A d j u s t e d t o P u m p I n l e t fo r P f - E l e v - H o s e F l o w A1 - A d j u s t e d S t a t i c : 7 2 . 4 0 1 A2 - A d j R e s i d : 6 4 @ 2 0 A3 - A d j R e s i d : 2 6 . 6 3 2 @ 5 0 Al + P 1 A2 + P 2 A3 + P 3 A2 A3 P1 - P u m p C h u r n P r e s s u r e : 6 7 . 5 P2 - P u m p R a t e d P r e s s u r e : 6 1 P2 - P u m p R a t e d F l o w : 2 0 P3 - P u m p P r e s s u r e @ M a x F l o w : 4 1 . 6 P3 - P u m p M a x F l o w : 5 0 Ci t y R e s i d u a l F l o w @ 0 = 6 6 5 5 . 4 1 Ci t y R e s i d u a l F l o w @ 2 0 = 5 8 1 0 . 0 2 Ci t y W a t e r @ 1 5 0 % o f P u m p = 8 9 . 9 9 D1D2 D1 - E l e v a t i o n : 1 4 . 2 3 8 D2 - S y s t e m F l o w : 4 7 . 0 4 D2 - S y s t e m P r e s s u r e : 7 3 . 1 7 2 Ho s e ( D e m a n d ) : _ _ _ _ _ _ _ D3 - S y s t e m D e m a n d : 4 7 . 0 4 Sa f e t y M a r g i n : 2 . 5 3 5 Wa t e r S u p p l y C u r v e ( C ) Co m p u t e r P r o g r a m s b y H y d r a t e c I n c . R o u t e 1 1 1 W i n d h a m N . H . U S A 0 3 0 8 7 Ce n t r a l F i r e P r o t e c t i o n Page3 Ca s a C o l o r a d o Date10-06-12 Fi t t i n g L e g e n d Abbrev. N a m e ½ ¾ 1 1 ¼ 1 ½ 2 2 ½ 3 3 ½ 4 5 6 8 1 0 1 2 1 4 1 6 1 8 2 0 2 4 Bv B B a l l M i l w B B - S C 1 0 0 2 . 2 5 2 2 . 5 2 . 2 5 1 0 Cpe * C P V C 9 0 ' E l l H a r v e l - S p e a r s 7 7 8 9 1 1 1 2 1 3 0 0 0 0 0 0 0 0 0 0 0 0 Cpt * C P V C T e e - B r a n c h 3 3 5 6 8 1 0 1 2 1 5 0 0 0 0 0 0 0 0 0 0 0 0 Cu e * C o p p e r 9 0 ' E l l 1 1 2 2 2 . 5 3 . 5 4 5 6 7 9 1 0 0 0 0 0 0 0 0 0 Cu t * C o p p e r T e e - B r a n c h 1 . 5 2 2 3 3 . 5 5 6 7 . 5 9 1 0 . 5 1 3 1 5 0 0 0 0 0 0 0 0 Fs p F l o w S w i t c h P o t t e r V S R F i t t i n g g e n e r a t e s a F i x e d L o s s B a s e d o n F l o w S N F P A 1 3 S w i n g C h e c k 0 0 5 7 9 1 1 1 4 1 6 1 9 2 2 2 7 3 2 4 5 5 5 6 5 Un i t s S u m m a r y Di a m e t e r U n i t s I n c h e s Le n g t h U n i t s F e e t Fl o w U n i t s U S G a l l o n s p e r M i n u t e Pr e s s u r e U n i t s P o u n d s p e r S q u a r e I n c h No t e : F i t t i n g L e g e n d p r o v i d e s e q u i v a l e n t p i p e l e n g t h s f o r f i t t i n g s t y p e s o f v a r i o u s d i a m e t e r s . Eq u i v a l e n t l e n g t h s s h o w n a r e s t a n d a r d f o r a c tu a l d i a m e t e r s o f S c h e d 4 0 p i p e a n d C F a c t o r s of 1 2 0 e x c e p t a s n o t e d w i t h * . T h e f i t t i n g s m a rk e d w i t h a * s h o w e q u i v a l e n t l e n g t h s v a l u e s su p p l i e d b y m a n u f a c t u r e r s b a s e d o n s p e c i f i c p i p e d i a m e t e r s a n d C F a c t o r s a n d t h e y r e q u i r e n o ad j u s t m e n t . A l l v a l u e s f o r f i t t i n g s n o t m a r k e d w i t h a * w i l l b e a d j u s t e d i n t h e c a l c u l a t i o n fo r C F a c t o r s o f o t h e r t h a n 1 2 0 a n d d i a m e t e r s o t h e r t h a n S c h e d 4 0 p e r N F P A . Fi t t i n g s U s e d S u m m a r y Co m p u t e r P r o g r a m s b y H y d r a t e c I n c . R o u t e 1 1 1 W i n d h a m N . H . U S A 0 3 0 8 7 Central Fire Protection Page4 Casa Colorado Date10-06-12 NodeElevationK-FactPtPnFlowDensityAreaPress No.ActualActualReq. S127.8754.429.84 na 24.040.07132427.3 S227.8754.427.33 na 23.00.07132427.3 L1A27.87530.34 na L2A27.87527.98 na L1B19.7135.33 na L2B19.7132.85 na L319.7134.98 na L427.87533.72 na L519.0439.2 na L68.2149.8 na L98.2157.96 na TOR8.2160.94 na PMPO1.073.17 na PMPI1.031.52 na BFO2.034.35 na BFI2.043.82 na BOR1.052.9 na TEST-5.089.99 na The maximum velocity is 19.41 and it occurs in the pipe between nodes BOR and TEST Pressure / Flow Summary - STANDARD Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Central Fire Protection Page5 Casa Colorado Date10-06-12 Hyd.QaDia.FittingPipePtPt Ref."C"orFtng'sPePv*******Notes****** PointQtPf/FtEqv.Ln.TotalPfPn *THIRD FLOOR S1 24.041.1011Cpt5.0 0.250 29.841K Factor = 4.40 to150.00.0 5.0000.0 L1A24.040.09540.0 5.250 0.501Vel = 8.10 0.0 24.04 30.342K Factor = 4.36 S2 23.001.1011Cpe7.0 0.333 27.334K Factor = 4.40 to150.00.0 7.0000.0 L2A23.00.08810.0 7.333 0.646Vel = 7.75 0.0 23.00 27.980K Factor = 4.35 *VERTICAL RISERS FROM 2ND TO 3RD L1A 24.041.1011Cpe7.0 8.170 30.342 to150.00.0 7.000 3.536 L1B24.040.09560.0 15.170 1.451Vel = 8.10 0.0 24.04 35.329K Factor = 4.04 L2A 23.001.1011Cpe7.0 8.170 27.980 to150.00.0 7.000 3.536 L2B23.00.08820.0 15.170 1.338Vel = 7.75 0.0 23.00 32.854K Factor = 4.01 *2ND FLOOR PIPING L1B 24.041.1011Cpe7.0 20.500 35.329 to150.02Cpt10.0 17.000 0.290 L524.040.09560.0 37.500 3.585Vel = 8.10 0.0 24.04 39.204K Factor = 3.84 L2B 23.001.1012Cpt10.0 14.170 32.854 to150.00.0 10.0000.0 L323.00.08810.0 24.170 2.130Vel = 7.75 L30.01.1012Cpe14.0 11.833 34.984 to150.00.0 14.000 -3.536 L423.00.08810.0 25.833 2.277Vel = 7.75 L40.01.1011Cpe7.0 6.750 33.725 to150.01Cpt5.0 12.000 3.826 L523.00.08820.0 18.750 1.653Vel = 7.75 0.0 23.00 39.204K Factor = 3.67 *VERTICAL RISER FROM 1ST TO 2ND L5 47.041.1011Cpe7.0 10.830 39.204 to150.00.0 7.000 4.690 L647.040.33110.0 17.830 5.904Vel = 15.85 0.0 47.04 49.798K Factor = 6.67 Final Calculations - Hazen-Williams Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Central Fire Protection Page6 Casa Colorado Date10-06-12 Hyd.QaDia.FittingPipePtPt Ref."C"orFtng'sPePv*******Notes****** PointQtPf/FtEqv.Ln.TotalPfPn *FIRST FLOOR PIPING L6 47.041.1011Cpe7.0 7.670 49.798 to150.02Cpt10.0 17.0000.0 L947.040.33100.0 24.670 8.167Vel = 15.85 L90.01.1011Cpe7.0 2.000 57.965 to150.00.0 7.0000.0 TOR47.040.33110.0 9.000 2.980Vel = 15.85 TOR0.01.0551Fsp0.0 7.210 60.945 to150.01S7.768 7.768 6.123* Fixed loss = 3 PMPO47.040.40750.0 14.978 6.104Vel = 17.26 0.0 47.04 73.172K Factor = 5.50 System Demand Pressure 73.172 Safety Margin 2.535 Continuation Pressure 75.707 Pressure @ Pump Outlet 75.707 Pressure From Pump Curve-44.189 Pressure @ Pump Inlet 31.518 PMPI0.01.0552Cue4.0 4.000 31.518 to150.00.0 4.000 -0.433 BFO47.040.40760.0 8.000 3.261Vel = 17.26 BFO0.01.0550.0 1.170 34.346 to150.00.00.0 9.000* Fixed loss = 9 BFI47.040.40770.0 1.170 0.477Vel = 17.26 BFI0.01.0551Cue2.0 1.000 43.823 to150.01Bv3.496 5.496 6.433* Fixed loss = 6 BOR47.040.40750.0 6.496 2.647Vel = 17.26 BOR0.00.9952Cue4.0 55.000 52.903 to150.01Cut2.0 8.628 2.599 TEST47.040.54201Bv2.628 63.628 34.489Vel = 19.41 0.0 47.04 89.991K Factor = 4.96 Final Calculations - Hazen-Williams Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Central Fire Protection 10775 E. 51st Ave. Denver, Colorado 80239 (303) 576-8157 Job Name:Casa Colorado Building:1042 Eagles Nest Circle Vail‚ Colorado Location:Second Floor Living Room System:Calc #2 Contract:290712 Data File:Casa Colorado Second Floor Living Room Calc #2.WX1 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Central Fire Protection Page1 Casa Colorado Date10-06-12 HYDRAULIC DESIGN INFORMATION SHEET Name - Casa Colorado Date - 10-06-2012 Location - Second Floor Living Room Building - 1042 Eagles Nest Circle Vail‚ Colorado System No. - Calc #2 Contractor - Central Fire Protection Contractors Inc Contract No. - 290712 Calculated By - Stephanie Pelster Drawing No. - FP1 Construction: (X) Combustible ( ) Non-Combustible Ceiling Height 9'-11" OCCUPANCY - NFPA 13D Residential S Type of Calculation: ( )NFPA 13 Residential ( )NFPA 13R (X)NFPA 13D Y Number of Sprinklers Flowing: ( )1 (X)2 ( )4 ( ) S ( )Other T ( )Specific Ruling Made by Date E M Listed Flow at Start Point - 20 Gpm System Type Listed Pres. at Start Point - 23.8 Psi (X) Wet ( ) Dry D MAXIMUM LISTED SPACING 20 x 20 ( ) Deluge ( ) PreAction E Domestic Flow Added - N/A Gpm Sprinkler or Nozzle S Additional Flow Added - N/A Gpm Make GLOBE Model MILLENNIUM I Elevation at Highest Outlet - Feet Size 1/2" K-Factor 4.1 G Note: Temperature Rating 155 N Calculation Gpm Required 42.992 Psi Required 62.847 pump outlet Summary C-Factor Used: Overhead 150 Underground 150 W Water Flow Test: Pump Data: Tank or Reservoir: A Date of Test - 10-01-2012 Rated Cap. 50 Cap. T Time of Test - 10:00 AM @ Psi 41.6 Elev. E Static (Psi) - 100 Elev. 1' R Residual (Psi) - 95 Other Well Flow (Gpm) - 1318 Proof Flow Gpm S Elevation - 2' P Location: 1042 Eagles Nest Circle Vail‚ Colorado 81657 P L Source of Information: Test conducted by Central Fire Protection Contractors Y and witnessed by Vail Fire & Upper Eagle Valley Fire Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Ce n t r a l F i r e P r o t e c t i o n Page2 Ca s a C o l o r a d o Date10-06-12 12243648 E 60 R 72 U 84 S 96 S 10 8 E 12 0 R 13 2 P 14 4 15 6 16 8 18 0 20 0 4 0 0 6 0 0 8 0 0 1 0 0 0 1 2 0 0 1 4 0 0 1 6 0 0 1 8 0 0 FL O W ( N ^ 1 . 8 5 ) Ci t y W a t e r S u p p l y : P u m p D a t a : D e m a n d : C1 C2 C1 - S t a t i c P r e s s u r e : 9 0 C2 - R e s i d u a l P r e s s u r e : 8 5 . 5 C2 - R e s i d u a l F l o w : 1 3 1 8 A1 Ci t y W a t e r A d j u s t e d t o P u m p I n l e t fo r P f - E l e v - H o s e F l o w A1 - A d j u s t e d S t a t i c : 7 2 . 4 0 1 A2 - A d j R e s i d : 6 4 @ 2 0 A3 - A d j R e s i d : 2 6 . 6 3 2 @ 5 0 Al + P 1 A2 + P 2 A3 + P 3 A2 A3 P1 - P u m p C h u r n P r e s s u r e : 6 7 . 5 P2 - P u m p R a t e d P r e s s u r e : 6 1 P2 - P u m p R a t e d F l o w : 2 0 P3 - P u m p P r e s s u r e @ M a x F l o w : 4 1 . 6 P3 - P u m p M a x F l o w : 5 0 Ci t y R e s i d u a l F l o w @ 0 = 6 6 5 5 . 4 1 Ci t y R e s i d u a l F l o w @ 2 0 = 5 8 1 0 . 0 2 Ci t y W a t e r @ 1 5 0 % o f P u m p = 8 9 . 9 9 D1D2 D1 - E l e v a t i o n : 1 0 . 4 6 8 D2 - S y s t e m F l o w : 4 2 . 9 9 2 D2 - S y s t e m P r e s s u r e : 6 2 . 8 4 7 Ho s e ( D e m a n d ) : _ _ _ _ _ _ _ D3 - S y s t e m D e m a n d : 4 2 . 9 9 2 Sa f e t y M a r g i n : 2 2 . 4 5 0 Wa t e r S u p p l y C u r v e ( C ) Co m p u t e r P r o g r a m s b y H y d r a t e c I n c . R o u t e 1 1 1 W i n d h a m N . H . U S A 0 3 0 8 7 Ce n t r a l F i r e P r o t e c t i o n Page3 Ca s a C o l o r a d o Date10-06-12 Fi t t i n g L e g e n d Abbrev. N a m e ½ ¾ 1 1 ¼ 1 ½ 2 2 ½ 3 3 ½ 4 5 6 8 1 0 1 2 1 4 1 6 1 8 2 0 2 4 Bv B B a l l M i l w B B - S C 1 0 0 2 . 2 5 2 2 . 5 2 . 2 5 1 0 Cpe * C P V C 9 0 ' E l l H a r v e l - S p e a r s 7 7 8 9 1 1 1 2 1 3 0 0 0 0 0 0 0 0 0 0 0 0 Cpt * C P V C T e e - B r a n c h 3 3 5 6 8 1 0 1 2 1 5 0 0 0 0 0 0 0 0 0 0 0 0 Cu e * C o p p e r 9 0 ' E l l 1 1 2 2 2 . 5 3 . 5 4 5 6 7 9 1 0 0 0 0 0 0 0 0 0 Cu t * C o p p e r T e e - B r a n c h 1 . 5 2 2 3 3 . 5 5 6 7 . 5 9 1 0 . 5 1 3 1 5 0 0 0 0 0 0 0 0 Fs p F l o w S w i t c h P o t t e r V S R F i t t i n g g e n e r a t e s a F i x e d L o s s B a s e d o n F l o w S N F P A 1 3 S w i n g C h e c k 0 0 5 7 9 1 1 1 4 1 6 1 9 2 2 2 7 3 2 4 5 5 5 6 5 Un i t s S u m m a r y Di a m e t e r U n i t s I n c h e s Le n g t h U n i t s F e e t Fl o w U n i t s U S G a l l o n s p e r M i n u t e Pr e s s u r e U n i t s P o u n d s p e r S q u a r e I n c h No t e : F i t t i n g L e g e n d p r o v i d e s e q u i v a l e n t p i p e l e n g t h s f o r f i t t i n g s t y p e s o f v a r i o u s d i a m e t e r s . Eq u i v a l e n t l e n g t h s s h o w n a r e s t a n d a r d f o r a c tu a l d i a m e t e r s o f S c h e d 4 0 p i p e a n d C F a c t o r s of 1 2 0 e x c e p t a s n o t e d w i t h * . T h e f i t t i n g s m a rk e d w i t h a * s h o w e q u i v a l e n t l e n g t h s v a l u e s su p p l i e d b y m a n u f a c t u r e r s b a s e d o n s p e c i f i c p i p e d i a m e t e r s a n d C F a c t o r s a n d t h e y r e q u i r e n o ad j u s t m e n t . A l l v a l u e s f o r f i t t i n g s n o t m a r k e d w i t h a * w i l l b e a d j u s t e d i n t h e c a l c u l a t i o n fo r C F a c t o r s o f o t h e r t h a n 1 2 0 a n d d i a m e t e r s o t h e r t h a n S c h e d 4 0 p e r N F P A . Fi t t i n g s U s e d S u m m a r y Co m p u t e r P r o g r a m s b y H y d r a t e c I n c . R o u t e 1 1 1 W i n d h a m N . H . U S A 0 3 0 8 7 Central Fire Protection Page4 Casa Colorado Date10-06-12 NodeElevationK-FactPtPnFlowDensityAreaPress No.ActualActualReq. S00119.294.127.24 na 21.40.053540023.8 S319.17K = K @ EQ0124.1 na 21.4 L319.7124.89 na S419.71K = K @ EQ0124.53 na 21.59 L419.0427.17 na L519.0432.43 na L68.2142.12 na L98.2149.03 na TOR8.2151.56 na PMPO1.062.85 na PMPI1.037.79 na BFO2.040.11 na BFI2.049.52 na BOR1.058.19 na TEST-5.089.99 na The maximum velocity is 17.74 and it occurs in the pipe between nodes BOR and TEST Pressure / Flow Summary - STANDARD Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Central Fire Protection Page5 Casa Colorado Date10-06-12 Hyd.QaDia.FittingPipePtPt Ref."C"orFtng'sPePv*******Notes****** PointQtPf/FtEqv.Ln.TotalPfPn *SPRINKLER EQUIV K-FACTORS S001 21.401.1011Cpe7.0 0.420 27.243K Factor = 4.10 to150.00.0 7.000 -3.718 EQ0121.40.07710.0 7.420 0.572Vel = 7.21 0.0 21.40 24.097K Factor = 4.36 *2ND FLOOR PIPING S3 21.401.1011Cpt5.0 8.333 24.097K Factor @ node EQ01 to150.00.0 5.000 -0.234 L321.40.07720.0 13.333 1.029Vel = 7.21 L30.01.1012Cpe14.0 11.833 24.892 to150.00.0 14.000 0.290 L421.40.07710.0 25.833 1.992Vel = 7.21 0.0 21.40 27.174K Factor = 4.11 S4 21.591.1012Cpe14.0 11.000 24.532K Factor @ node EQ01 to150.01Cpt5.0 19.000 0.290 L421.590.07840.0 30.000 2.352Vel = 7.28 L4 21.401.1011Cpe7.0 6.750 27.174 to150.01Cpt5.0 12.0000.0 L542.990.28030.0 18.750 5.256Vel = 14.49 0.0 42.99 32.430K Factor = 7.55 *VERTICAL RISER FROM 1ST TO 2ND L5 42.991.1011Cpe7.0 10.830 32.430 to150.00.0 7.000 4.690 L642.990.28030.0 17.830 4.998Vel = 14.49 0.0 42.99 42.118K Factor = 6.62 *FIRST FLOOR PIPING L6 42.991.1011Cpe7.0 7.670 42.118 to150.02Cpt10.0 17.0000.0 L942.990.28030.0 24.670 6.915Vel = 14.49 L90.01.1011Cpe7.0 2.000 49.033 to150.00.0 7.0000.0 TOR42.990.28030.0 9.000 2.523Vel = 14.49 TOR0.01.0551Fsp0.0 7.210 51.556 to150.01S7.768 7.768 6.123* Fixed loss = 3 PMPO42.990.34500.0 14.978 5.168Vel = 15.78 0.0 42.99 62.847K Factor = 5.42 System Demand Pressure 62.847 Safety Margin 22.450 Continuation Pressure 85.297 Pressure @ Pump Outlet 85.297 Pressure From Pump Curve-47.510 Pressure @ Pump Inlet 37.787 Final Calculations - Hazen-Williams Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Central Fire Protection Page6 Casa Colorado Date10-06-12 Hyd.QaDia.FittingPipePtPt Ref."C"orFtng'sPePv*******Notes****** PointQtPf/FtEqv.Ln.TotalPfPn PMPI0.01.0552Cue4.0 4.000 37.787 to150.00.0 4.000 -0.433 BFO42.990.34510.0 8.000 2.761Vel = 15.78 BFO0.01.0550.0 1.170 40.115 to150.00.00.0 9.000* Fixed loss = 9 BFI42.990.34440.0 1.170 0.403Vel = 15.78 BFI0.01.0551Cue2.0 1.000 49.518 to150.01Bv3.496 5.496 6.433* Fixed loss = 6 BOR42.990.34510.0 6.496 2.242Vel = 15.78 BOR0.00.9952Cue4.0 55.000 58.193 to150.01Cut2.0 8.628 2.599 TEST42.990.45891Bv2.628 63.628 29.200Vel = 17.74 0.0 42.99 89.992K Factor = 4.53 Final Calculations - Hazen-Williams Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Central Fire Protection 10775 E. 51st Ave. Denver, Colorado 80239 (303) 576-8157 Job Name:Casa Colorado Building:1042 Eagles Nest Circle Vail‚ Colorado Location:First Floor Garage 107 System:Calc #3 Contract:290712 Data File:Casa Colorado First Floor Garage 107 Calc #3.WX1 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Central Fire Protection Page1 Casa Colorado Date10-06-12 HYDRAULIC DESIGN INFORMATION SHEET Name - Casa Colorado Date - 10-06-2012 Location - First Floor Garage 107 Building - 1042 Eagles Nest Circle Vail‚ Colorado System No. - Calc #3 Contractor - Central Fire Protection Contractors Inc Contract No. - 290712 Calculated By - Stephanie Pelster Drawing No. - FP1 Construction: (X) Combustible ( ) Non-Combustible Ceiling Height 9' OCCUPANCY - NFPA 13D Residential S Type of Calculation: ( )NFPA 13 Residential ( )NFPA 13R (X)NFPA 13D Y Number of Sprinklers Flowing: ( )1 (X)2 ( )4 ( ) S ( )Other T ( )Specific Ruling Made by Date E M Listed Flow at Start Point - 25 Gpm System Type Listed Pres. at Start Point - 32.3 Psi (X) Wet ( ) Dry D MAXIMUM LISTED SPACING 16 x 20 ( ) Deluge ( ) PreAction E Domestic Flow Added - N/A Gpm Sprinkler or Nozzle S Additional Flow Added - N/A Gpm Make TYCO Model LFII DRY I Elevation at Highest Outlet - Feet Size 1/2" K-Factor 4.4 G Note: Temperature Rating 155 N Calculation Gpm Required 50.387 Psi Required 77.937 At Pump Outlet Summary C-Factor Used: Overhead 150 Underground 150 W Water Flow Test: Pump Data: Tank or Reservoir: A Date of Test - 10-01-2012 Rated Cap. 50 Cap. T Time of Test - 10:00 AM @ Psi 41.6 Elev. E Static (Psi) - 100 Elev. 1' R Residual (Psi) - 95 Other Well Flow (Gpm) - 1318 Proof Flow Gpm S Elevation - 2' P Location: 1042 Eagles Nest Circle Vail‚ Colorado 81657 P L Source of Information: Test conducted by Central Fire Protection Contractors Y and witnessed by Vail Fire & Upper Eagle Valley Fire Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Ce n t r a l F i r e P r o t e c t i o n Page2 Ca s a C o l o r a d o Date10-06-12 12243648 E 60 R 72 U 84 S 96 S 10 8 E 12 0 R 13 2 P 14 4 15 6 16 8 18 0 20 0 4 0 0 6 0 0 8 0 0 1 0 0 0 1 2 0 0 1 4 0 0 1 6 0 0 1 8 0 0 FL O W ( N ^ 1 . 8 5 ) Ci t y W a t e r S u p p l y : P u m p D a t a : D e m a n d : C1 C2 C1 - S t a t i c P r e s s u r e : 9 0 C2 - R e s i d u a l P r e s s u r e : 8 5 . 5 C2 - R e s i d u a l F l o w : 1 3 1 8 A1 Ci t y W a t e r A d j u s t e d t o P u m p I n l e t fo r P f - E l e v - H o s e F l o w A1 - A d j u s t e d S t a t i c : 7 2 . 4 0 1 A2 - A d j R e s i d : 6 4 @ 2 0 A3 - A d j R e s i d : 2 6 . 6 3 2 @ 5 0 Al + P 1 A2 + P 2 A3 + P 3 A2 A3 P1 - P u m p C h u r n P r e s s u r e : 6 7 . 5 P2 - P u m p R a t e d P r e s s u r e : 6 1 P2 - P u m p R a t e d F l o w : 2 0 P3 - P u m p P r e s s u r e @ M a x F l o w : 4 1 . 6 P3 - P u m p M a x F l o w : 5 0 Ci t y R e s i d u a l F l o w @ 0 = 6 6 5 5 . 4 1 Ci t y R e s i d u a l F l o w @ 2 0 = 5 8 1 0 . 0 2 Ci t y W a t e r @ 1 5 0 % o f P u m p = 8 9 . 9 9 D1D2 D1 - E l e v a t i o n : 5 . 7 2 1 D2 - S y s t e m F l o w : 5 0 . 3 8 7 D2 - S y s t e m P r e s s u r e : 5 5 . 1 7 4 Ho s e ( D e m a n d ) : _ _ _ _ _ _ _ D3 - S y s t e m D e m a n d : 5 0 . 3 8 7 Sa f e t y M a r g i n : 1 2 . 0 5 2 Wa t e r S u p p l y C u r v e ( C ) Co m p u t e r P r o g r a m s b y H y d r a t e c I n c . R o u t e 1 1 1 W i n d h a m N . H . U S A 0 3 0 8 7 Ce n t r a l F i r e P r o t e c t i o n Page3 Ca s a C o l o r a d o Date10-06-12 Fi t t i n g L e g e n d Abbrev. N a m e ½ ¾ 1 1 ¼ 1 ½ 2 2 ½ 3 3 ½ 4 5 6 8 1 0 1 2 1 4 1 6 1 8 2 0 2 4 Bv B B a l l M i l w B B - S C 1 0 0 2 . 2 5 2 2 . 5 2 . 2 5 1 0 Cpe * C P V C 9 0 ' E l l H a r v e l - S p e a r s 7 7 8 9 1 1 1 2 1 3 0 0 0 0 0 0 0 0 0 0 0 0 Cpt * C P V C T e e - B r a n c h 3 3 5 6 8 1 0 1 2 1 5 0 0 0 0 0 0 0 0 0 0 0 0 Cu e * C o p p e r 9 0 ' E l l 1 1 2 2 2 . 5 3 . 5 4 5 6 7 9 1 0 0 0 0 0 0 0 0 0 Cu t * C o p p e r T e e - B r a n c h 1 . 5 2 2 3 3 . 5 5 6 7 . 5 9 1 0 . 5 1 3 1 5 0 0 0 0 0 0 0 0 Fs p F l o w S w i t c h P o t t e r V S R F i t t i n g g e n e r a t e s a F i x e d L o s s B a s e d o n F l o w S N F P A 1 3 S w i n g C h e c k 0 0 5 7 9 1 1 1 4 1 6 1 9 2 2 2 7 3 2 4 5 5 5 6 5 Un i t s S u m m a r y Di a m e t e r U n i t s I n c h e s Le n g t h U n i t s F e e t Fl o w U n i t s U S G a l l o n s p e r M i n u t e Pr e s s u r e U n i t s P o u n d s p e r S q u a r e I n c h No t e : F i t t i n g L e g e n d p r o v i d e s e q u i v a l e n t p i p e l e n g t h s f o r f i t t i n g s t y p e s o f v a r i o u s d i a m e t e r s . Eq u i v a l e n t l e n g t h s s h o w n a r e s t a n d a r d f o r a c tu a l d i a m e t e r s o f S c h e d 4 0 p i p e a n d C F a c t o r s of 1 2 0 e x c e p t a s n o t e d w i t h * . T h e f i t t i n g s m a rk e d w i t h a * s h o w e q u i v a l e n t l e n g t h s v a l u e s su p p l i e d b y m a n u f a c t u r e r s b a s e d o n s p e c i f i c p i p e d i a m e t e r s a n d C F a c t o r s a n d t h e y r e q u i r e n o ad j u s t m e n t . A l l v a l u e s f o r f i t t i n g s n o t m a r k e d w i t h a * w i l l b e a d j u s t e d i n t h e c a l c u l a t i o n fo r C F a c t o r s o f o t h e r t h a n 1 2 0 a n d d i a m e t e r s o t h e r t h a n S c h e d 4 0 p e r N F P A . Fi t t i n g s U s e d S u m m a r y Co m p u t e r P r o g r a m s b y H y d r a t e c I n c . R o u t e 1 1 1 W i n d h a m N . H . U S A 0 3 0 8 7 Central Fire Protection Page4 Casa Colorado Date10-06-12 NodeElevationK-FactPtPnFlowDensityAreaPress No.ActualActualReq. S18.214.432.3 na 25.010.07832032.3 L78.2132.89 na S28.214.433.27 na 25.380.07832032.3 L88.2133.88 na L98.2138.74 na TOR8.2142.12 na PMPO1.055.17 na PMPI1.025.97 na BFO2.029.24 na BFI2.038.78 na BOR1.048.22 na TEST-5.089.99 na The maximum velocity is 20.79 and it occurs in the pipe between nodes BOR and TEST Pressure / Flow Summary - STANDARD Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Central Fire Protection Page5 Casa Colorado Date10-06-12 Hyd.QaDia.FittingPipePtPt Ref."C"orFtng'sPePv*******Notes****** PointQtPf/FtEqv.Ln.TotalPfPn *FIRST FLOOR PIPING S1 25.011.1011Cpt5.0 0.708 32.300K Factor = 4.40 to150.00.0 5.0000.0 L725.010.10280.0 5.708 0.587Vel = 8.43 L70.01.1010.0 9.625 32.887 to150.00.00.00.0 L825.010.10290.0 9.625 0.990Vel = 8.43 0.0 25.01 33.877K Factor = 4.30 S2 25.381.1011Cpt5.0 0.708 33.274K Factor = 4.40 to150.00.0 5.0000.0 L825.380.10560.0 5.708 0.603Vel = 8.55 L8 25.011.1011Cpt5.0 7.920 33.877 to150.00.0 5.0000.0 L950.390.37600.0 12.920 4.858Vel = 16.98 L90.01.1011Cpe7.0 2.000 38.735 to150.00.0 7.0000.0 TOR50.390.37590.0 9.000 3.383Vel = 16.98 TOR0.01.0551Fsp0.0 7.210 42.118 to150.01S7.768 7.768 6.123* Fixed loss = 3 PMPO50.390.46290.0 14.978 6.933Vel = 18.49 0.0 50.39 55.174K Factor = 6.78 System Demand Pressure 55.174 Safety Margin 12.052 Continuation Pressure 67.226 Pressure @ Pump Outlet 67.226 Pressure From Pump Curve-41.252 Pressure @ Pump Inlet 25.974 PMPI0.01.0552Cue4.0 4.000 25.974 to150.00.0 4.000 -0.433 BFO50.390.46290.0 8.000 3.703Vel = 18.49 BFO0.01.0550.0 1.170 29.244 to150.00.00.0 9.000* Fixed loss = 9 BFI50.390.46240.0 1.170 0.541Vel = 18.49 BFI0.01.0551Cue2.0 1.000 38.785 to150.01Bv3.496 5.496 6.433* Fixed loss = 6 BOR50.390.46290.0 6.496 3.007Vel = 18.49 BOR0.00.9952Cue4.0 55.000 48.225 to150.01Cut2.0 8.628 2.599 TEST50.390.61551Bv2.628 63.628 39.165Vel = 20.79 0.0 50.39 89.989K Factor = 5.31 Final Calculations - Hazen-Williams Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087