HomeMy WebLinkAboutA12-0063 stamped approved PO Box 1073, Frisco, CO 80443 970.409.9082; fax 970.797.1898 October 10, 2012 Mike Vaughan Vail Fire & Emergency Services Vail, Colorado Re: Millrace Condominiums Dear Mike, This letter outlines a scope of work to be performed at the Millrace Condominiums. The work will be completed by Vail Electronics. Buildings #1, 2, 4, 5, 6 & 7 will be affected by this project. There will be 4 fire alarm control panels installed. See the attached spreadsheet and site plan. We will install the following: • 4 Honeywell, Vista 128FPB fire alarm panels with wireless capabilities and dialers • 4 Honeywell 6160CR wireless keypads in heated enclosures • 74 5800WAVE wireless sounders • 116 5808W3 wireless smoke detectors • 45 5800CO wireless carbon monoxide detectors Panel and keypad locations have been discussed on site during our recent walkthrough with Don Anderson from Vail Electronics. Hand drawn typical plans of each unit type are attached. I have also provided battery calculations. The attached spreadsheet outlines the number of devices per unit, per building and per panel. Of course, a zone list will be produced as installation progresses and will be provided to you at the final inspection. The attached site plan shows notations for panel locations and building numbers. The panels will be partitioned per unit. Each unit will operate independently of others. A smoke detector or carbon monoxide detector activation will activate all sounders within a unit. There is no General Alarm condition – each unit will operate separately. If you have any questions or need any additional information for issuance of a permit, please let me know. Sincerely, Deborah L. Shaner, P.E. Fire Protection Engineer Cc: Don Anderson, Vail Electronics 10/10/2012 A12-0063 Millrace Condominiums Fire Alarm Installation Device/FACP Summary FACP #1, Building #1 Located in Building #1, Covers Units 1A-1H Unit Type # of Smoke Detectors # of CO Detectors # of Sounders 1A 2 bedroom 3 1 2 1B 2 bedroom 3 1 2 1C 2 bedroom 3 1 2 1D 2 bedroom 3 1 2 1E 3 bedroom 5 2 3 1F 3 bedroom 5 2 3 1G 3 bedroom 5 2 3 1H 3 bedroom 5 2 3 Totals 32 12 20 FACP #2, Building #2 Located in Building #2, Covers Units 2A-2F Unit Type # of Smoke Detectors # of CO Detectors # of Sounders 2A 1 bedroom 2 1 1 2B 1 bedroom 2 1 1 2C 1 bedroom 2 1 1 2D 2 bedroom + loft 4 2 3 2E 2 bedroom + loft 4 2 3 2F 2 bedroom + loft 4 2 3 Totals 18 9 12 FACP #3, Buildings #4 & 5 Located in Building #5, Covers Units 4A-4D & 5A-5D Unit Type # of Smoke Detectors # of CO Detectors # of Sounders 4A 2 bedroom 3 1 2 4B 2 bedroom 3 1 2 4C 3 bedroom + loft 6 2 4 4D 3 bedroom + loft 6 2 4 5A 2 bedroom 3 1 2 5B 2 bedroom 3 1 2 5C 3 bedroom 5 2 3 5D 3 bedroom 5 2 3 Totals 34 12 22 FACP #4, Buildings #6 & 7 Located in Building #7, Covers Units 6A-6D & 7A-7D Unit Type # of Smoke Detectors # of CO Detectors # of Sounders 6A 2 bedroom 3 1 2 6B 2 bedroom 3 1 2 6C 3 bedroom 5 2 3 6D 3 bedroom 5 2 3 7A 2 bedroom 3 1 2 7B 2 bedroom 3 1 2 7C 3 bedroom 5 2 3 7D 3 bedroom 5 2 3 Totals 32 12 20 Grand Totals 116 45 74 ~MILLRACECONDOMINIUMS 970.476.6106 TO HOTEL &SPA/CLUB •. ••North C>NM o BLDG.2 GARAGEr---'r""""I DlelBIA Millrace 1&2 BUILDING #4:PARK IN ASSIGNED GARAGE ATTACHED TO YOUR BUILDING. BUILDINGS #5,#6,#7:GARAGE IS LOCATED UNDER YOUR SPECIFIC CONDOMINIUM. ~ VAIL CASCADE RESORT·SPA·CONDOMINIUMS OJ STAIRS TO HOTELnm K1l-iA- t -~tb.Jr\... Standby Number of Current Total Current Device Type Devices (Amps)(Amps) Main FACP CPU 1 X 0.032 =0.032 Wireless Interface 1 X 0.025 =0.025 Keypad 1 X 0.04 =0.04 SUM COLUMN FOR STANDBY LOAD 0.097 =AMPS Alarm Load Number of Current Total Current Device Type Devices (Amps)(Amps) Main FACP CPU 1 X 0.032 =0.032 Wireless Interface 1 X 0.025 =0.025 Keypad 1 X 0.1 =0.1 Sounder 22 X 0.066 =1.452 SUM COLUMN FOR STANDBY LOAD 1.609 =AMPS Standby Load Required Standby Time in Hours Current (Amps) 0.097 X 24 =2.33 Alarm Load Required Alarm Time in Hours Current (Amps)(15 MINUTES) 1.609 X 0.25 =0.40 Add Standby and Alarm Load for Required Ampere Hour Battery 2.73 Multiply by the Derating Factor of 1.2 Total Ampere Hours Required =3.28 Batteries Provided:4AH Minimum Panel calculations is worst case of 4 panels. All battery sizes will be 4AH. Ademco Vista 128 FACP Millrace Condominiums r\'- 4.-r '-- I l".~1dtr)JjJ \,AA\Jll ~)-+.J~ I 1 I\Il J \ .}~I ~f(J @.@ ~~I.I r 1~>{2lo{VVl ~1 '-!1l?Q (9 -' '••,\0. rv ' ;-- J-.~ ~»M ~'---" - @ ~~--I.....-- .----t -..-:-_.-L-_