Loading...
HomeMy WebLinkAboutB12-0189 Rev 1 plans approvedTRANSMITTAL FORM Project Street Address: __________ ______________________________ ___________ (Number) (Street) (Suite #) Building/Complex Name: ________________________________ Revised ADDITIONAL Valuations (Labor & Materials) (DO NOT include original valuation) Building: $_____________________ Plumbing: $_____________________ Electrical: $_____________________ Mechanical: $_____________________ Total: $_____________________ Description / List of Changes: __________________________________________________ __________________________________________________ __________________________________________________ __________________________________________________ __________________________________________________ __________________________________________________ (use additional sheet if necessary) Permit #(s) information applies to: Attention: ( ) Revisions ( ) Response to Correction Letter ____________________________________ __________________________ ___attached copy of correction letter ( ) Deferred Submittal ____________________________________ __________________________ ( ) Other Revision Submittals: 1. “Field Set” of approved plans MUST accompany revisions. 2. No further inspections will be performed until the revisions are approved & the permit is re-issued. 3. Fees for reviewing revisions are $55.00 per hour (2 hour minimum), and are due upon issuance. Date Received: 01-Oct-11 Department of Community Development 75 South Frontage Road Vail, CO 81657 Tel: 970-479-2128 www.vailgov.com Development Review Coordinator For Office Use Only: Fee Paid: _________________________________________ Received From: ____________________________________ Cash _________ Check # ___________ CC: Visa / MC Last 4 CC # _________ exp. date: ________ Auth # _________ Contractor Information Business Name: ________________________________________ Business Address: ______________________________________ City _____________________ State: _______ Zip: ____________ Contact Name: _________________________________________ Contact Phone: _________________________________________ Contact E-Mail: _________________________________________ I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the town's zoning and subdivision codes, design review ap- proved, International Building and Residential Codes and other ordinances of the Town applicable thereto. X___________________________________________________ Owner/Owner’s Representative Signature (Required) Applicant Information Applicant Name: _______________________________________ Applicant Phone: _______________________________________ Applicant E-Mail: _______________________________________ Owner'sRepresentative B12-0189Haeberle 1416Moraine Drive GilletteLLC PostOfficeBox5821 VailCO81658 BrianGillette 970.390.7981 brian_gillette@gillettellc.con JobHernandez 970.333.2097 jobhernandezmn@prodigy.net.mx 1.Deletepatiostorage a.SeeA1.1,A2.1,A2.2,A3.1,A4.2,E1.1,S2,S3,S5 2.ReplaceNEBedroompatiowithroof. a.SeeA1.1,A2.2,A3.1,A4.2,E1.2,S3,S5 0 09/26/2012 7:47AM 28 26 MORAINE DRIVE (50') 81 3 0 .5'X 8 1 27.5 'X 812 5 .4'X S44°09'23"E 177.62' LOT 9 86.81' N44°22'31"W 169.28' N39°18'43"E 72.51' LOT 7 28 26 MORAINE DRIVE (50') 81 3 0 .5'X 8 1 27.5 'X S44°09'23"E 177.62' 86.81' N44°22'31"W 169.28' N39°18'43"E 72.51' LOT 7 8 1 3 0 8 1 2 8 8126 8 1 3 2 8 1 3 0 8128 8126 8 1 2 4 8122 8120 8120 8122 8124 81 1 0 81 1 0 LOT 8 15,136 SQUARE FEET 0.348 ACRES DRIVEWAY SLAB ASPHALT - NO HEAT 1,350 SQ. FT. LIGHT FIXTURE NOTE: (2) WALL MOUNTED LIGHT FIXTURES SHOWN. ALL OTHERS ARE RECESSED CANS, NOT SHOWN. UNDISTURBED GRADES SNOW STORAGE AREA: 30% OF DRIVEWAY = 405 SQ. FT. 8125' 8125.5' 8124.5' 8124' 8125' MAIN LEVEL - F.F. 8126'-0 3/4" (0'-0") UPPER LEVEL - F.F. 8137'-2 1/8" (11'-1 3/8") ON-GRADE PATIO 8125'-10" 9X18 CAR 9X18 CAR 9X19 CAR GARAGE LEVEL 8125'-6" (-0'-6") EXISTING SIDEWALK SE T B A C K SE T B A C K SETBACK ENTRY PATIO 8125'-10" WATERPROOF DECK OVER LIVING AREA 8131' BOULDER RETAINING WALL: 2' HEIGHT T.O.WALL = 8128'-0" B.O.WALL = 8126'-0" CONC RETAINING WALL: 3' HEIGHT T.O.WALL = 8129'-0" B.O.WALL = 8126'-0" METERS G WATER S EWE R GAS PHONE/TV ELEC CONTRACTOR TO VERIFY LOCATION OF UTILITY STUB-OUTS PRIVACY WALL 1.25% SLOPE 64 ' - 0 " 11 ' - 7 1 / 8 " CONSTRUCTION BOUNDARY FENCE: EROSION CONTROL - FENCE/BAIL 10 ' - 0 " BOULDER RETAINING WALL: 2' HEIGHT T.O.WALL = 8127'-6" B.O.WALL = 8125'-6" 8130' EXTERIOR LIGHTING: (2) WALL SCONCES BOULDER RETAINING WALL: 2' HEIGHT T.O.WALL = 8129'-6" B.O.WALL = 8127'-6" 10'-0" 10 ' - 0 " 5' - 0" 8150'-8 13/16" T.O.RIDGE 8157'-0 5/16" T.O.RIDGE 8150'-3 11/16" T.O.RIDGE 8157'-0 5/16" T.O.RIDGE 8143'-7 11/16" T.O.RIDGE 8152'-11 5/8" T.O.RIDGE 8158'-6 5/16" T.O.CHIMNEY 8156'-0 5/16" T.O.RIDGE 8157'-6" T.O.PARAPET 8154'-1 7/8" T.O.ROOF8150'-8 5/16" T.O.RIDGE FOUNDATION DRAIN PIPES AND TERMINATION RE: SOILS INVESTIGATION REPORT FOUNDATION DRAINS HIGH-POINT, START OF SLOPE REVISION 6-6-12 PERMIT CHECKLIST REVISION 6-6-12 PERMIT CHECKLIST LOWER ROOF 4:12 PITCH DECK 2 2 8 1 3 0 8 1 2 8 8126 8 1 3 2 LANDSCAPE LEGEND SYMBOL NAME SIZE QUANTITY COLORADO BLUE SPRUCE (PICEA PUNGENS) 6' - 8' TALL 4A QUAKING ASPEN (POPULUS TREMULOIDES) 2" - 3" CAL.6B FLOWERING CRAB APPLE (MALUS SPP.) 3" CAL.1C WESTERN SANDCHERRY (PRUNUS BESSEYI) 5 GALLON 4D VANHOUTTE SPIREA (SPIREA VANHOUTTE) 5 GALLON 4E LILAC FRAGRANT (SYRINGA VULGARIS) 5 GALLON 4F SNOWBERRY (SYMPHORICARPOS ALBUS) 5 GALLON 4G NATURAL GRASSES AREA = 2850 S.F. LANDSCAPE NOTE: ALL DISTURBED AREAS SHALL RECIEVE REVEGETATION SEEDING WITH NATURAL GRASSES AND WILDFLOWER SEED MIX. IRRIGATION NOTE: ALL AREAS OF NEW SOD TO RECIEVE SPRAY IRRIGATION. ALL AREAS OF GROUND COVER AND TREE/SHRUB PLANGINGS TO RECEIVE UNDER-GROUND DRIP IRRIGATION. ALL IRRIGATION SYSTEMS TO BE DESIGNED BY A LANDSCAPE CONTRACTOR AND SUBMITTED TO THE ARCHITECT AND/OR OWNER FOR APPROVAL PRIOR TO INSTALLATION. RAIN SENSOR NOTE: THE IRRIGATION SYSTEM SHALL BE EQUIPPED WITH A RAIN SENSOR. EROSION CONTROL NOTE: ALL DISTURBED AREAS WITHOUT FORMAL LANDSCAPING TO RECIEVE REVEGETATION SEEDING. EROSION CONTROL SHALL BE MAINTAINED BY PLACEMENT OF HAY BAILS AND SILT FENCING ON DOWNSLOPE SIDE OF LOT AND IN DRAINAGE SWALES.A G D BB G A F F F E D A G C E G E B B E A D B B F D OWNER GARDEN NATURAL GRASSES NATURAL GRASSES NATURAL GRASSES 97 0 . 3 2 8 . 5 1 5 1 O F F I C E PO B o x 1 5 8 7 , E a g l e , C O 8 1 6 3 1 ww w . m a r t i n m a n l e y a r c h i t e c t s . c o m Project number Date REVISIONS 7/ 2 4 / 2 0 1 2 4 : 2 6 : 1 4 P M Du a p h i n a i s - M o s e l e y F i l i n g 1 , L o t 8 To w n o f V a i l , E a g l e C o u n t y , C o l o r a d o A1.1 SI T E & L A N D S C A P E P L A N 0408 14 1 6 M O R A I N E D R I V E BU I L D I N G P E R M I T 6-6-23 PERMIT: 5-1-12 BR I A N G I L L E T T E 1" = 10'-0"1 SITE PLAN 1416 MORAINE DRIVE - LOT 8 GRAND TRAVERSE - VAIL 1" = 10'-0"2 LANDSCAPE PLAN GRFA ALLOWED: NOT APPLICABLE GRFA PROPOSED: 6,392 SQ. FT. LIVING AREA PROPOSED:5,579 SQ. FT. LOT AREA = .348 ACRES x 43,560 SQ. FT. = 15,136 SQ. FT. SITE COVERAGE ALLOWED (25% OF SITE) = 3,784 SQ. FT. SITE COVERAGE PROPOSED = 3,780 SQ. FT TOWN OF VAIL - SPECIAL DEVELOPMENT DISTRICT: SSD 22 - GRAND TRAVERSE - LOT 8 HEIGHT LIMIT = 33'-0" PROPOSED HEIGHT = 32'-11" PARKING SPACES REQUIRED: 3 SPACES PARKING SPACES PROPOSED: 2 SPACES (INTERIOR) 1 SPACE (EXTERIOR) Single Family Residence - New Construction Location: 1416 Moraine Drive, Vail, CO 81657 Lot 8, Dauphinais-Moseley, Filing 1 Parcel #2103-122-09-032 Owner: Job G. Hernandez & Ana P. Rosas PO Box 3708 Vail, CO 81658 Contractor:Gillette LLC Construction Brian Gillette - 888-719-1123 PO Box 5821, Vail, CO 81658 brian_gillette@gillettellc.com Architect: Martin Manley Architects John G. Martin - 970-328-0592 john@martinmanleyarchitects.com PROJECT / CODE SUMMARY Class of Work: New Construction Type of Construction: Type V-N Type of Occupancy: R3 (single family) Levels: 2-story ROOF OVERHANGS ALLOWED INTO SETBACK: 2 FEET PATIO ENCROACHMENT INTO REAR SETBACK: 5 FEET Architectural Drawing List Sheet Number Sheet Name A1.1SITE & LANDSCAPE PLAN A2.1MAIN LEVEL FLOOR PLAN A2.2UPPER LEVEL FLOOR PLAN A2.3ROOF PLAN A3.1ELEVATIONS - NORTH & EAST A3.2ELEVATIONS - SOUTH & WEST A4.1FRAMING SECTIONS A4.2SECTIONS A6.2WINDOWS Grand total: 9 REFRENCE NO R T H Engineering Drawing List Sheet Number Sheet Name S1 GENERAL NOTES/DETAILS S2 FOUNDATION PLAN S3 UPPER FLOOR FRAMING PLAN S4 ROOF FRAMING PLAN S5 FRAMING DETAILS M1.0 MECHANICAL E1.1 MAIN LEVEL LIGHTING E1.2 UPPER LEVEL LIGHTING No . D e s c r i p t i o n D a t e 1 R e v i s i o n 1 6- 6 - 1 2 2 R e v i s i o n 2 7- 2 4 - 1 2 09/26/2012 Reviewed for Code Compliance Code: 2009 International Residential Code (IRC) By Martin Haeberle at 7:46 am, Oct 15, 2012 14 1 6 M o r a i n e D r i v e Reviewed for Code Compliance Code: 2009 International Residential Code (IRC) By Martin Haeberle at 7:46 am, Oct 15, 2012 14 1 6 M o r a i n e D r i v e Reviewed for Code Compliance Code: 2009 International Residential Code (IRC) By Martin Haeberle at 7:46 am, Oct 15, 2012 14 1 6 M o r a i n e D r i v e Reviewed for Code Compliance Code: 2009 International Residential Code (IRC) By Martin Haeberle at 7:46 am, Oct 15, 2012 01 Main Level 8126' - 0 3/4" Roof Plate 8146' - 2 1/8" 02 Upper Level 8137' - 2 1/8" 4' - 1 0 3 / 4 " METER CLOSET GAS METER METAL RAILING W/ WOOD CAP VERTICAL CEDAR BOARD AND BATTEN SIDING STUCCO WALL W/ DEEP INSET WINDOWS SYNTHETIC WOOD SHAKE SHINGLES WITH STAGGARD BUTTS "RAINBOW ROCK" STONE VENEER CEDAR "BELLY BAND" STUCCO COPPER CAP STONE SILL AT ALL WINDOWS IN STUCCO WALLS 1 2 4 10 24 27 2 01 Main Level 8126' - 0 3/4" Roof Plate 8146' - 2 1/8" 02 Upper Level 8137' - 2 1/8" 3 16 17 18 19 20 21 22 23 32 34 35 36 37 38 39 5' HEIGHT MAX. COLD STORAGE 2 2 970.328.5151 OFFICE PO Box 1587, Eagle, CO 81631 www.martinmanleyarchitects.com Project number Date REVISIONS 7/ 2 4 / 2 0 1 2 4 : 2 6 : 2 8 P M Du a p h i n a i s - M o s e l e y F i l i n g 1 , L o t 8 To w n o f V a i l , E a g l e C o u n t y , C o l o r a d o A3.1 ELEVATIONS - NORTH & EAST 0408 14 1 6 M O R A I N E D R I V E BU I L D I N G P E R M I T 6-6-23 PERMIT: 5-1-12 BR I A N G I L L E T T E 1/4" = 1'-0"1 ELEVATION - NORTH 1/4" = 1'-0"2 ELEVATION - EAST No . D e s c r i p t i o n D a t e 2 R e v i s i o n 2 7- 2 4 - 1 2 Reviewed for Code Compliance Code: 2009 International Residential Code (IRC) By Martin Haeberle at 7:46 am, Oct 15, 2012 01 Main Level 8126' - 0 3/4"Roof Plate 8146' - 2 1/8"02 Upper Level 8137' - 2 1/8" 13 14 15 29 31 33 01 Main Level 8126' - 0 3/4"Roof Plate 8146' - 2 1/8"02 Upper Level 8137' - 2 1/8"33' HEIGHT 33' - 0" 5 6 7 8 9 11 12 25 26 28 30970.328.5151 OFFICE PO Box 1587, Eagle, CO 81631 www.martinmanleyarchitects.com Project number DateREVISIONS 5/9/2012 8:38:24 AM Duaphinais-Moseley Filing 1, Lot 8 Town of Vail, Eagle County, Colorado A3.2 ELEVATIONS - SOUTH & WEST04081416 MORAINE DRIVE BUILDING PERMIT 5-1-12BRIAN GILLETTENo.DescriptionDate 1/4" = 1'-0"1ELEVATION - SOUTH 1/4" = 1'-0"2ELEVATION - WEST Re v i e w e d f o r C o d e C o m p l i a n c e Co d e : 2 0 0 9 I n t e r n a t i o n a l R e s i d e n t i a l C o d e ( I R C ) By Ma r t i n Ha e b e r l e at 7: 4 7 am , Oc t 15 , 20 1 2 14 1 6 M o r a i n e D r i v e Reviewed for Code Compliance Code: 2009 International Residential Code (IRC) By Martin Haeberle at 7:47 am, Oct 15, 2012 14 1 6 M o r a i n e D r i v e Reviewed for Code Compliance Code: 2009 International Residential Code (IRC) By Martin Haeberle at 7:47 am, Oct 15, 2012 CCA4048 CCA4048 CCA4048 37 38 39 CCA3636 VCMT3030 CCC3654 CCA6036 CCA6036 CCC3654 CCC3654 CWGPDT16080QCWGPDT12080QCISWT3080CISWT3080CIFRT5480 CWGPDT16080Q 24 25 26 27 28 29 30 31 32 33 34 35 36 CCA3636 VCMT3030 CCC3030 CCA3030 VCMT3030 CCA3030 CWGPDT16068Q 15 16 17 20 21 22 23 CCC3030 18 CCC2448 19 CCC3656 CCC3030 CA3224-21 CWGPDR9068 CISWR3068 CA4824-21 CCC3656 VCMT3030 CCA3636 CWGPDT12068Q CCC2424 1 2 3 4 5 6 7 8 9 10 11 12 13 14 14 1 6 M o r a i n e D r i v e Reviewed for Code Compliance Code: 2009 International Residential Code (IRC) By Martin Haeberle at 7:47 am, Oct 15, 2012 14 1 6 M o r a i n e D r i v e PROJECT SUMMARY Outdoor Temp -21F Elevation 9000 Wind Speed 10 mph Supply Fluid 135F Total Heated Area 4922sf Radiant Load 192,537 BTU/h Snowmelt Load 198,315 BTU/h Domestic Hot Load 486,000 BTU/h Reviewed for Code Compliance Code: 2009 International Residential Code (IRC) By Martin Haeberle at 7:47 am, Oct 15, 2012 14 1 6 M o r a i n e D r i v e Reviewed for Code Compliance Code: 2009 International Residential Code (IRC) By Martin Haeberle at 7:47 am, Oct 15, 2012 14 1 6 M o r a i n e D r i v e Reviewed for Code Compliance Code: 2009 International Residential Code (IRC) By Martin Haeberle at 7:47 am, Oct 15, 2012 HI L L S T R U C T U R A L D E S I G N 07/24/2012 Reviewed for Code Compliance Code: 2009 International Residential Code (IRC) By Martin Haeberle at 7:47 am, Oct 15, 2012 HI L L S T R U C T U R A L D E S I G N 07/24/2012 Reviewed for Code Compliance Code: 2009 International Residential Code (IRC) By Martin Haeberle at 7:47 am, Oct 15, 2012 HI L L S T R U C T U R A L D E S I G N 07/24/2012 Reviewed for Code Compliance Code: 2009 International Residential Code (IRC) By Martin Haeberle at 7:47 am, Oct 15, 2012 HI L L S T R U C T U R A L D E S I G N 07/24/2012 Reviewed for Code Compliance Code: 2009 International Residential Code (IRC) By Martin Haeberle at 7:48 am, Oct 15, 2012 HI L L S T R U C T U R A L D E S I G N 07/24/2012 Reviewed for Code Compliance Code: 2009 International Residential Code (IRC) By Martin Haeberle at 7:48 am, Oct 15, 2012