HomeMy WebLinkAboutDRB120461 Approved PlansLIONSHEAD
WELCOME CENTER
LIONSHEAD
WELCOME CENTER
BUILDING SIGNAGE & GRAPHICS
Design Intent
4 October, 2012
prepared for the
1112 Pearl Street Boulder, CO 80302
TEL 303.447.8202
FAX 303.440.7069
www.commarts-boulder.com
www.stantec.com
4Oc
LI
O
N
S
H
E
A
D
W
E
L
C
O
M
E
C
E
N
T
E
R
BLDG. SIGNAGE & GRAPHICSDesign Intent4 October, 2012
Lionshead Welcome CenterTown of Vail
PROJECT
Greg Hall, Town of Vail
CLIENT CONTACT
HB, JM, DT
TEAM
Table of Contents
0.1
1112 Pearl Street Boulder, CO 80302TEL 303.447.8202 FAX 303.440.7069www.commarts-boulder.comwww.stantec.com
These drawings express visual design intent only. Final engineering, materials and fabrication shall remain the responsibility of the fabricator.
table of contents
Sign Inventory
Performance Specifications
Materials & Finishes
Fonts & Symbols
Location Plans
Sign Drawings
Identification
Informational
Directional
0.1
0.2
0.3
0.4
0.LP
1.1
2.1
3.1
LI
O
N
S
H
E
A
D
W
E
L
C
O
M
E
C
E
N
T
E
R
BLDG. SIGNAGE & GRAPHICSDesign Intent4 October, 2012
Lionshead Welcome CenterTown of Vail
PROJECT
Greg Hall, Town of Vail
CLIENT CONTACT
HB, JM, DT
TEAM
Sign Inventory
0.1
1112 Pearl Street Boulder, CO 80302TEL 303.447.8202 FAX 303.440.7069www.commarts-boulder.comwww.stantec.com
These drawings express visual design intent only. Final engineering, materials and fabrication shall remain the responsibility of the fabricator.
These drawings express visual design intent only. Final engineering, materials and fabrication shall remain the responsibility of the fabricator.
$ 25,000
$ 25,000
$ 15,000
$ 2,000
$ 6,000
$ 300
$ 100
$ 500
$ 3,000
$ 100
$ 100
$ 10
$ 1,000
$ 100
$ 1,000
$ 4,000
$ 25,000
$ 25,000
$ 15,000
$ 2,000
$ 18,000
$ 600
$ 200
$ 1,000
$ 9,000
$ 5,600
$ 5,600
$ 4,250
$ 10,000
$ 1,100
$ 3,000
$ 4,000
Quantity Description Sign TypePage No.Unit Cost Ext'd Cost
-
1
2
1
1
1
1
1
9
1
5 (10 panels)
1 (2 panels)
1 (1 panel)
1
1
3
4
8
16
-
1 (2 units)
-
2
4
2
6
5
9
2
1
IDENTIFICATION
Primary Project I.D.
Secondary Welcome Center I.D.
Transit Center I.D.
Entry I.D.
Primary Project Entry I.D.
VRD Entry I.D.
The Grand View Entry I.D.
Drop-Off, Short Term Parking Garage Entry (West Elevation)
Freestanding Short Term Parking Garage Entry
Facility I.D.
Flat Mount Icon Panels
Small Flat Mount Panels
Blade Mount Icon Panels
Single Pole Mount Icon Panels
Existing Pole Mount Icon Panels
Suspended Icon
Stained Icon
Level I.D.
Small Level I.D.
Public Room I.D. (with icon)
Smaller Public Room I.D. (no icon)
Designated Space I.D.
Clearance I.D.
Temp. I.D.
Virtual Concierge I.D.
INFORMATIONAL
Project Directories
Elevator Lobby Directory
Elevator Cab Directory
Entry Door Information
Entry Door 50th Anniversary Logos
Life Safety
Temporary/Moveable Informational
Misc. Informational
1.1.1
1.1.2
1.1.3
1.2.1
1.2.2
1.2.3
1.2.4
1.2.5
1.3.1
1.3.1s
1.3.2
1.3.3
1.3.4
1.3.5
1.3.6
1.4
1.4s
1.5
1.5s
1.6
1.7
1.8
1.9
2.1.1
2.1.2
2.2
2.2c
2.3
2.4
2.5
Project signature located at top of tower, highly visible from many directions and from a great distance. Iconographic landmark.
Project signature (not an entry) on North side of building at parking level 1 skier drop-off area. Externally illuminated corten sign panel and edge lit icon sign assemblies.
North and South elevations of Transit Center on Frontage Rd. Externally illuminated corten sign panel sign assembly.
Primary South face street level entry into Welcome Center facility. Externally illuminated corten sign panel and edge lit icon sign assemblies.
North 2nd level entry into VRD facilities. Externally illuminated corten sign panel sign assembly.
North 3rd level entry into Vail Community room (name TBD). Externally illuminated corten sign panel sign assembly.
West street level entry into short term/skier drop-off area of parking structure. (Existing) Externally illuminated corten sign panel and edge lit icon sign assemblies.
West street level entry into short term/skier drop-off area of parking structure. Externally illuminated corten sign panel and edge lit icon sign assemblies.
Metal sign face on fabricated frame pinned off (stone, wood,...) surfaces. Painted graphics. Non illuminated.
Smaller version of above.
Perpendicular mounted metal sign faces on fabricated frames attached to base plate. Painted graphics. Non illuminated.
Freestanding clustered pole assembly with blade mount sign panels.
Blade mount sign panels attached to an existing streetlight or pole.
Fabricated Information icon cabinet with edge illuminated frosted acrylic behind corten face plate. Assembly suspended from base plate.
Information icon presented at a very large scale and at very low contrast. Transparent stain on beetle-kill wood rear wall of info desk area.
Metal sign face on fabricated frame pinned off (stone, wood,...) surfaces. Painted graphics. Non illuminated.
Smaller version of above.
ADA compliant tactile identification signs for all rooms & spaces: restrooms, lockers, utility rooms. Current units should be replaced by project specific (color, typeface).
Smaller version of above. Not a public use room, no icon included.
Pole mount (typ.) sign panels identifying reserved parking spaces or curb areas. Project specific colors/typefaces replace any existing off-the-shelf units.
Suspended thin wall aluminum tubes identifying the clearance limits of the parking structure. Inexpensive machine-cut reflective & matte vinyl graphics.
Installed August, 2012
Metal sign face on fabricated frame pinned off wall surfaces. Painted graphics. Non illuminated.
Destination and facility listings, including international symbols, located at all elevator lobbies. May include Level I.D. sign violator panels.
Destination and facility listings, including international symbols, located in all elevator cabs.
Facility services/offerings on glass entry doors rendered in 2nd surface white matte machine-cut vinyl.
Temporary decals celebrating the town’s 50th anniversary. Full color digital prints on white vinyl.
Code required life safety signs: Maximum Occupancy, Stairwell Informational, These Doors to Remain Open...., In Case of Fire....
Vehicular and Pedestrian scaled temporary/moveable sign assemblies, deployed as required.
As required.
sign inventory
LI
O
N
S
H
E
A
D
W
E
L
C
O
M
E
C
E
N
T
E
R
BLDG. SIGNAGE & GRAPHICSDesign Intent4 October, 2012
Lionshead Welcome CenterTown of Vail
PROJECT
Greg Hall, Town of Vail
CLIENT CONTACT
HB, JM, DT
TEAM
Sign Inventory
cont.
0.1.2
1112 Pearl Street Boulder, CO 80302TEL 303.447.8202 FAX 303.440.7069www.commarts-boulder.comwww.stantec.com
These drawings express visual design intent only. Final engineering, materials and fabrication shall remain the responsibility of the fabricator.
These drawings express visual design intent only. Final engineering, materials and fabrication shall remain the responsibility of the fabricator.
$ 25,000
$ 25,000
$ 15,000
$ 2,000
$ 6,000
$ 300
$ 100
$ 500
$ 3,000
$ 100
$ 100
$ 10
$ 1,000
$ 100
$ 1,000
$ 4,000
$ 25,000
$ 25,000
$ 15,000
$ 2,000
$ 18,000
$ 600
$ 200
$ 1,000
$ 9,000
$ 5,600
$ 5,600
$ 4,250
$ 10,000
$ 1,100
$ 3,000
$ 4,000
Quantity Description Sign TypePage No.Unit Cost Ext'd Cost
1
-
4
-
-
1 (3 panels)
-
2
DIRECTIONAL
Vehicular Directional
Vehicular Banner Pole
Pedestrian Directional
Flat Mount Directional
Blade Mount Directional
Pole Cluster Mount Directional
Existing Pole Mount Directional
Single Tapering Pole Mount
Misc. Directional
THEMATIC
Map Display Holders
3.1.1
3.1.2
3.2.1
3.2.2
3.2.3
3.2.4
3.2.5
3.3
4.5
Directional sign panels, scaled and positioned for vehicular use. Signs typically rely upon reflective vinyls for visibility.
Large scale vertical pole mounted banners. Adds color & graphics, aids in direction
Metal sign face on fabricated frame pinned off (stone, wood,...) surfaces. Painted graphics. Non illuminated.
Perpendicular mounted metal sign faces on fabricated frames attached to base plate.
Same sign assembly as above mounted to a freestanding clustered pole assembly. Non-illuminated.
Blade mount sign panels attached to an existing streetlight or pole.
Same sign assembly as above mounted to a single, tapering, banded post assembly. Non-illuminated.
2-Layer acrylic frames suspended bu floor to ceiling cable system.
sign inventory
LI
O
N
S
H
E
A
D
W
E
L
C
O
M
E
C
E
N
T
E
R
BLDG. SIGNAGE & GRAPHICSDesign Intent4 October, 2012
Lionshead Welcome CenterTown of Vail
PROJECT
Greg Hall, Town of Vail
CLIENT CONTACT
HB, JM, DT
TEAM
ContractorPerformance and Material Requirements
0.2
1112 Pearl Street Boulder, CO 80302TEL 303.447.8202 FAX 303.440.7069www.commarts-boulder.comwww.stantec.com
These drawings express visual design intent only. Final engineering, materials and fabrication shall remain the responsibility of the fabricator.
required to complete fabrication and installation of the specified work.
Full compliance with these Contractor Performance and Material
Requirements will be required.The Contractor is encouraged to make
recommendations for specific changes if they will improve the quality or
cost-effectiveness of fabrication while preserving Stantec/CommArts’ visual
design intent. However, any such recommendations must be approved in
writing by the Owner and Stantec/CommArts at the time of bid. Should the
Contractor be contracted based on a proposal that assumes substitutions that
have not been properly approved, the Contractor shall be responsible for
providing all elements as originally indicated at their own expense.
B. Shop Drawings
The Contractor shall submit shop drawings of all fabricated items to the
Owner and Stanec/CommArts. This submission shall consist of three hard
copy sets of detailed drawings that indicate all materials, finishes, construction
details, lighting requirements, installation details and artwork, including
locations of all material seams. Drawings shall include elevations, plans,
sections and notes as required to clearly convey fabrication intent.
Stantec/CommArts will review samples for aesthetic appearance and
compatibility with adjacent conditions. Compliance with other requirements is
the exclusive responsibility of the Contractor.
Upon review, the Contractor shall make all requested revisions and resubmit
as required. A complete set of approved shop drawings (noted “No
Exceptions Taken” or “Exceptions as Noted”) must be received from both
the Owner and Stantec/CommArts before production may begin.
C. Submittals
The Contractor is responsible for providing submittals to the Owner and
Stantec/CommArts as required per “Quantities & Submittals” section of this
document. Stantec/CommArts will review samples for aesthetic appearance
and compatibility with adjacent conditions. Compliance with other
requirements is the exclusive responsibility of the Contractor.
All materials, finishes and content are subject to revision until final
submittals have been approved. A complete set of approved submittals
must be received from both the Owner and Stantec/CommArts before
fabrication may begin. Required submittals must be issued in an adequate
time frame to allow review, adjustments and approval without delaying the
project schedule.
III. FABRICATION & INSTALLATION REQUIREMENTS
A. Permitting & Regulation Compliance
The Contractor is responsible for securing and paying for all permits,
insurances, inspections and tests required by governmental agencies. The
Contractor is responsible for submitting all necessary permit information to the
Building Department review and approval for all applicable permits as rquired
per the Town of Vail and 2011 IBC. The Fabricator is also responsible for
verifying and ensuring compliance
This document has been assembled by Stantec/CommArts
with the expectation that the Contractor will meet the following quality and
performance requirements. The acceptance of these drawings by the Fabricator
constitutes agreement to comply with the following conditions. The Owner will
hold the Fabricator to these requirements as part of their contract obligations.
I. GENERAL
A. Proprietary Information Non-Disclosure Agreement
All ideas, designs, arrangements and plans indicated orpresented by
these drawings are the property of the Owner and were created for use in
connection with the specified project. The information in this document is
confidential and shall not be disseminated to anyone other than
Stantec/CommArts, the Owner or the Contractor’s personnel necessary to execute
the contract, without the written permission of Stantec/CommArts and the Owner.
In addition, the Contractor must request and receive written approvals from
both the Owner and Stantec/CommArts to use images of any completed
element. The Contractor is responsible for ensuring that credit indicating
Stantec/CommArts as the Designer will accompany all images and articles
related to the project. The Owner may have additional requirements or
restrictions for which the Contractor is also responsible.
B. Design Intent Drawings
The “design intent” drawings contained in this document are for the
sole purpose of expressing visual design intent and are not intended for
construction purposes. All aspects of fabrication, installation and any
resulting working drawings, shop drawings, submittals, building permits
meeting 2011 IBC with necessary professionally engineered drawings and
contract documents are the responsibility of the Contractor.
Within the design intent drawings:
• All written dimensions take precedence over dimensions otherwise
implied by drawing scale, figures, etc.
• Large scale details take precedence over the smaller scale drawings.
• Specific recommendations for materials, colors and content take
precedence over representations shown in drawings.
II. PRE-FABRICATION REQUIREMENTS
A. Proposal
Copies of all pricing and bid information shall be sent to the Owner and
Stantec/CommArts. The Contractor shall base their proposal on the performance
of all items or service including labor, materials, equipment and resources.
with all ADA, OSHA, environmental regulations and all other applicable
governing code requirements. All required resolutions or revisions to
construction details must be approved by the Owner and Stantec/CommArts
prior to production.
B. Structural Requirements
The Contractor shall follow Stantec/CommArts’ drawings for exterior visual
appearance but designs of internal structure, engineered connections,
mounting assemblies and foundations are by the Contractor. Structural
design shall utilize self-supportive framing and prevent irregularities in
exposed surfaces.
Deliverables:
• The Contractor shall reference Architecural Drawings for full mounting
location conditions and shall coordinate all necessary waterproofing,
support and/or blocking requirements and approximate weights for each
element as required no later than twenty-one days after final shop drawing
approval. Drawings will be provided in electronic format (PDF) by Owner.
• The Fabricator shall provide the Owner and/or the GC with calculations
for all structural members and foundations sealed by certified engineers
registered in the state of installation, prior to fabrication.
C. Electrical Requirements
Design of all electrical components is by the Contractor. All transformers
and electrical hardware shall be concealed (i.e. non-audible and non-visible
to pedestrian and vehicular traffic). The Contractor shall ensure all electrical
components are easily accessible for maintenance and servicing.
All necessary point-of-connection coordination is the responsibility of the
Contractor. All connections must be in compliance with the requirements of
the NEC and all other applicable governing code requirements. All necessary
electrical components and assemblies are to be UL listed or approved by a
nationally recognized testing lab.
All electrical components shall be warranted against failure for at least
two years. Within the warranty period, defective electrical components
are to be replaced by the Contractor within forty-eight hours of notice by
the Owner. Should the Contractor fail to replace defective components within
the specified time, these items may be replaced by others at the Contractor’s
expense.
Deliverables:
• The Contractor shall provide the Owner with a list of electrical requirements
for each element no later than twenty-one days after final shop drawing
approval.
D. Lighting
The Contractor shall follow Stantec/CommArts’ drawings for visual appearance
but design of internal structure, fixtures and mounting assemblies is by the
contractor per formance
& material requirements
LI
O
N
S
H
E
A
D
W
E
L
C
O
M
E
C
E
N
T
E
R
BLDG. SIGNAGE & GRAPHICSDesign Intent4 October, 2012
Lionshead Welcome CenterTown of Vail
PROJECT
Greg Hall, Town of Vail
CLIENT CONTACT
HB, JM, DT
TEAM
ContractorPerformance and Material Requirements
0.2.2
1112 Pearl Street Boulder, CO 80302TEL 303.447.8202 FAX 303.440.7069www.commarts-boulder.comwww.stantec.com
These drawings express visual design intent only. Final engineering, materials and fabrication shall remain the responsibility of the fabricator.
H. Safety & Responsibility
The Contractor shall be responsible for providing barricade or protective
coverings as necessary to safeguard the public and property during the
performance and duration of their work. The Contractor shall be fully
responsible for any injuries to the public or damage to the buildings, site
and adjacent objects during installation. The Contractor shall be responsible
for cleaning up all work areas upon the completion of work on a daily basis.
All installed items shall be left in a clean and as-new condition. The
Contractor shall be fully responsible for the security and quality of all
equipment, materials and installed components until they have been
reviewed and accepted by the Owner.
III. MATERIAL STANDARDS
All materials, hardware and finishes used to fabricate any and all components
shall be new (i.e. not previously used or operated in any other application) and
from the most recent manufacturer’s production supply.
A. Paints & Finishes
All paints and finishes shall match exactly the color, finish and texture
noted. Unless otherwise noted, all pretreats, primers, coatings and
finishes shall be applied in strict accordance with the paint manufacturer’s
specifications to provide the highest level of ultraviolet light resistance,
weatherability and overall longevity for both the materials indicated and the
environmental conditions of the final install locations.
Paints & finishes shall be warranted against color fading, UV damage
cracking, peeling, blistering and other defects in materials or workmanship
for a minimum of five years from date of Owners acceptance.
B. Metals
Metals shall be the best commercial quality for the purposes specified and
free from defects impairing strength, durability or appearance. Unless
otherwise noted, all visible seams are to be continuously welded, filled and
ground smooth. All sheet metal shall have brake formed edges with radii
not greater than sheet thickness. All metals must be treated to prevent
corrosion and staining of other finishes.
C. Fasteners
Unless otherwise noted, all exposed fasteners shall be tamper-proof,
resistant to oxidation and other corrosion and painted to match adjacent
surfaces. Concealed fasteners must be resistant to oxidation and other
corrosion to prevent staining of other finishes.
D. Vinyl
All vinyl sheeting shall match exactly the color, finish and durability of the
manufacturer’s product as noted. Unless otherwise noted, all vinyl sheeting
shall be installed in strict accordance with the manufacturer’s specifications
to provide the highest level of ultraviolet light resistance, weatherability and
overall longevity for both the materials indicated and the environmental
conditions of the final install locations.
Vinyl sheeting shall be warranted against color fading, UV damage,
delamination or peeling for a period of five years from date of Owner’s
acceptance.
E. Digital Prints
All high resolution digital output must provide the highest level of ultraviolet
light resistance, weatherability and overall longevity for both the materials
indicated and the environmental conditions of the final install locations.
Unless otherwise noted, digital prints shall have a minimum resolution of
200 dpi.
Printed product shall be warranted against color fading, UV damage,
delamination or peeling for a minimum of five years from date of the
Owner’s acceptance.
IV. PROJECT COMPLETION
A. Paints & Finishes
The Contractor shall notify both Stantec/CommArts and the Owner in writing
when all work is completed. Upon notice, Stantec/CommArts will review all work
according to their contract with the Owner and prepare a punch list
outlining incomplete or unsatisfactory items. The repair or replacement of
work outlined on the punch list shall be coordinated between the Contractor
and the Owner.
B. Final Deliverables
Upon the Owner’s acceptance of the work, the Contractor shall provide the
Owner with three copies of a complete service and maintenance manual for
all products and finishes installed under their contract. This manual shall
include, but is not limited to, product specifications such as manufacturer
information, contact names and addresses, warranty information, technical
data and routine maintenance recommendations for light fixtures, electrical
components, paint, finishes and all other applicable items.
C. Warranties
All warranty periods shall begin on the date of the Owner’s acceptance of
the work. All warranties shall include the materials and labor required to
replace defective components. Unless otherwise stated above, all installed
components shall be warranted against manufacturer defects for a minimum
of two years and all installed elements shall be warranted against defects in
installation or workmanship for a minimum of three years.
Contractor. The Contractor shall ensure all lighting components are easily
accessible for maintenance and servicing. Unless otherwise noted, the
interior of all illuminated enclosures shall be painted matte white to increase
reflectivity. All lighting components shall be constructed per recognized
national standards and/or specific manufacturer’s recommendations.
All neon components shall be warranted against failure for at least three
years and all other lighting components shall be warranted for at least
two years. Within the warranty periods, failed lighting components are to
be replaced by the Contractor within forty-eight hours of notice by the Owner.
Should the Contractor fail to replace defective components within the specified
time, these items may be replaced by others at the Contractor’s expense.
E. Labeling
Visible labels, manufacturer’s or otherwise, code permitting, shall not
appear on any completed element. The placement of any required labels
must be approved by Stantec/CommArts prior to application and installation.
F. Artwork & Fonts
Stantec/CommArts will provide the Contractor with layout guidelines and
electronic artwork as required, however all final copy layouts are the
responsibility of the Fabricator.
The Contractor shall legally acquire at their own expense all project fonts
from the specified distributors. Stantec/CommArts will not provide copies of
licensed fonts.
When stock imagery is used, Stantec/CommArts will provide the Fabricator
with the image specifications and a low resolution electronic file for placement.
The purchasing of high resolution final images, licensing and all applicable fees
are the responsibility of the Contractor. All acquired images shall be registered
in the Owner’s name.
G. On-Site Coordination
All locations shown in the enclosed location plans are approximate. The
Contractor is responsible for referencing applicable Architectural Drawings, field
verification and coordination of all final locations. The Contractor shall notify
the Owner and Stantec/CommArts of any discrepancies between
Stantec/CommArts’ drawings, location plans or message schedule and field
conditions prior to installation. All required resolutions or revisions to
construction details must be approved by the Owner and Stantec/CommArts
prior to production.
The Contractor’s installation responsibilities include the provision of any
required footings, anchor bolts or fastenings. All point-of-connection
coordination is the responsibility of the Contractor.
Deliverables:
• The Contractor shall provide the Owner with templates and patterns as
required no later than twenty-one days after final shop drawing approval.
LI
O
N
S
H
E
A
D
W
E
L
C
O
M
E
C
E
N
T
E
R
BLDG. SIGNAGE & GRAPHICSDesign Intent4 October, 2012
Lionshead Welcome CenterTown of Vail
PROJECT
Greg Hall, Town of Vail
CLIENT CONTACT
HB, JM, DT
TEAM
Materials & Finishes
0.3
1112 Pearl Street Boulder, CO 80302TEL 303.447.8202 FAX 303.440.7069www.commarts-boulder.comwww.stantec.com
These drawings express visual design intent only. Final engineering, materials and fabrication shall remain the responsibility of the fabricator.
P.3
Black15 MP32156 Black Magic
P.1
Dk. Lionshead Red114 MP15793 Town & Country Red
P.2
Lionshead Anthracite22 MP12718 Unicor Brown
P.4
White13 MP32351 White Spirit
Paints
V.1
Reflective White
3M Engineer Grade
Reflective White
V.2
Matte White
V.3
3-M Matte Black
Vinyl
M.1
Faux Corten FinishSample to be provided to Fabricator for matching
M.2
Frosted Acrylic
M.3
Non-glare Acrylic
Materials/Finishes
LI
O
N
S
H
E
A
D
W
E
L
C
O
M
E
C
E
N
T
E
R
BLDG. SIGNAGE & GRAPHICSDesign Intent4 October, 2012
Lionshead Welcome CenterTown of Vail
PROJECT
Greg Hall, Town of Vail
CLIENT CONTACT
HB, JM, DT
TEAM
Fonts, Artwork & Symbols
0.4
1112 Pearl Street Boulder, CO 80302TEL 303.447.8202 FAX 303.440.7069www.commarts-boulder.comwww.stantec.com
These drawings express visual design intent only. Final engineering, materials and fabrication shall remain the responsibility of the fabricator.
ABCDEFGHIJKLMNOPQRSTUVWXY & Z
abcdefghijklmnopqrstuvwxy & z
1234567890
ABCDEFGHIJKLMNOPQRSTUVWXY & Z
abcdefghijklmnopqrstuvwxy & z
1234567890
VAIL RECREATION
DISTRICT
Helvetica Neue LT Std. 67 Med. Condensed
Helvetica Neue LT Std. 77 Bold Condensed
Customized Icon for Bldg. I.D.
rendered in LionsHead Welcome Center material: corten
Bldg. Tenant I.D.’s
Client logos (currently not being used)
Vail Icons,
rendered in LionsHead Welcome Center Dk. Red
LI
O
N
S
H
E
A
D
W
E
L
C
O
M
E
C
E
N
T
E
R
BLDG. SIGNAGE & GRAPHICSDesign Intent4 October, 2012
Lionshead Welcome CenterTown of Vail
PROJECT
Greg Hall, Town of Vail
CLIENT CONTACT
HB, JM, DT
TEAM
Location Plan
Site Plan
0.LP.Site
1112 Pearl Street Boulder, CO 80302TEL 303.447.8202 FAX 303.440.7069www.commarts-boulder.comwww.stantec.com
These drawings express visual design intent only. Final engineering, materials and fabrication shall remain the responsibility of the fabricator.
Loc.
S.1
S.2
S.3S.4
Type
1.3.2
1.1.3
1.3.31.1.3
Message
(Icons: Restrooms, Bus Transit) (New pole)
LIONSHEAD VILLAGE Transit Center
(Icons: Restrooms, Bus Transit) (Blade mount)LIONSHEAD VILLAGE Transit Center
Loc.
S.5
S.6
S.7
Type
1.9
3.1.1
1.2.5
Message
(Icon) Interactive Virtual Concierge
Short Term Parking
(Icons) Drop-Off, Welcome Center
Lionshead Village Welcome Center
Drop-Off &
Short Term Parking Only (Arrow)
1.1.3S.4
1.3.3S.1
1.3.2S.3
1.1.3S.2
1.2.5S.7
3.1.1S.6
1.9S.5
LI
O
N
S
H
E
A
D
W
E
L
C
O
M
E
C
E
N
T
E
R
BLDG. SIGNAGE & GRAPHICSDesign Intent4 October, 2012
Lionshead Welcome CenterTown of Vail
PROJECT
Greg Hall, Town of Vail
CLIENT CONTACT
HB, JM, DT
TEAM
Location Plan
Level 1
0.LP1
1112 Pearl Street Boulder, CO 80302TEL 303.447.8202 FAX 303.440.7069www.commarts-boulder.comwww.stantec.com
These drawings express visual design intent only. Final engineering, materials and fabrication shall remain the responsibility of the fabricator.
1.3.11.11
1.3.1 1.12
1.71.1
1.2.41.2
1.41.13
1.41.14
1.3.11.21
1.3.11.22
1.3.11.23
1.3.11.24
1.2.11.33
1.3.41.32
2.2 1.34 2.2c 1.52
2.2c1.47
1.91.48
2.31.35
2.21.43 2.2c1.54
1.5s1.381.3.21.37
1.3.51.28
1.3.11.49 4.51.50 4.51.51
2.51.53
1.3.11.45
1.1.21.36
1.3.21.27
2.31.16
2.1.11.15
2.1.11.192.1.21.17
2.1.21.18
1.5s1.3
1.5s1.4
1.5s1.8
1.5s1.6
1.5s1.7
2.31.20
1.51.40
1.51.42
2.21.25
2.21.55
2.2c1.46 1.3.21.44
1.3.61.29
3.2.41.10
3.2.31.9
1.4s1.31
3.2.11.30
1.5s1.5
1.51.39
1.51.41
AB
Loc.
1.1
1.2
1.3
1.4
1.5
1.61.7
1.8
1.9
1.101.11
1.12
1.13
1.141.15
1.161.17
1.18
1.19
1.20
1.21
1.221.23
1.24
1.25
1.261.27
1.28
1.29
1.30
1.31
1.321.33
1.34
1.35 1.36
1.37
1.38
1.39
1.40
1.411.42
1.43
1.44
1.55
Type
1.7
1.2.4
1.5s
1.5s1.5s
1.5s
1.5s
1.5s3.2.3
3.2.4
1.3.1
1.3.1
1.41.4
2.1.1
2.32.1.2
2.1.2
2.1.1
2.31.3.1
1.3.1
1.3.1
1.3.12.2
2.2
1.3.2
1.3.5
1.3.6
3.2.1
1.4s1.3.4
1.2.1
2.2
2.3
1.1.2
1.3.2
1.5s
1.5
1.5
1.5
1.5
2.2
1.3.2
2.2
Message
Clearance 7'-0" (2 units)Lionshead Village Welcome Center
Drop-Off (icon)
Short Term Parking (icon)
TBD (Braille)
129 (Braille)
123 (Braille)
WATER ENTRY (Braille)
ELEVATOR MECHANICAL (Braille)
IT (Braille)(Arrow, Eco Transit, Restrooms)
(3) Panels: (Arrow, Info, Restrooms)
(Icon: Parking)
(Icon: Drop-Off)
p1, Do You Remember...
p1, Do You Remember...
3 The Grand View
(Icons: Restrooms, Eco Transit)
2 Vail Recreation District Imagination Station
VRD Community Programming
1 Drop-Off
Short Term Parking (Icon: Drop-Off)
Lobby/Street
Lionshead Village
(Icons: Info, Restrooms, Lockers, ATM)
In Case of Fire...(same as 1.15 above)
(same as 1.15 above)
3 The Grand View
(Icons: Restrooms, Eco Transit)2 Vail Recreation District
Imagination Station
VRD Community Programming
1 Drop-Off
Short Term Parking (Icon: Drop-Off)
Lobby/Street
Lionshead Village
(Icons: Info, Restrooms, Lockers, ATM)In Case of Fire...
(Icon: Handicap Access)
(Icon: Parking)
(Icon: Elevator)
(Icon: ATM)
Elevators & ADA Access to Parking, Address
LHWC, Restrooms, Public Lockers
(1) Panel: (Icon: Elevator)
(Icon: Information)(Icon: Information)
a Lionshead Village
(Icons: Information, Restrooms,
Lockers, ATM)
p1, Do You Remember....
(1) Panel: (Icon: Information)
Lionshead Village Welcome Center
(Icon: Information)
LHWCMaximum Occupancy 395
Lionshead Village Welcome Center
(Icon: Information)
(2) Panels: A (Icons: Restrooms, Lockers)
B (Icons: Information, Elevator)
ELECTRIC ROOM (Braille)
(Women) WOMEN (Braille)
(Family) FAMILY (Braille)
(Men) MEN (Braille)(Lockers) Public Lockers
Restrooms & Public Lockers
(Icons: Restrooms, Lockers) (blade mount)
LHWC, Restrooms & Lockers
Grayed back signs are not included in this
contract.
Loc.
1.45
1.46
1.47
1.48
1.49
1.50
1.51
1.521.53
1.54
Type
1.3.1
2.2c
2.2c
1.9
1.3.1
4.5
4.5
2.2c2.5
2.2c
Message
(Icon- Elevator)
(Vail’s 50th logo)
(Vail’s 50th logo)
(Icon) Interactive Virtual Concierge
Round panel (Arrow), square panel (Restrooms)
(Map holder)
(Map holder)(Vail’s 50th logo)
Short Term Locker Use Only....
(Vail’s 50th logo)
Deleted
Deleted
Deleted
Deleted Added
Added
Changed
Changed from 1.4 to 1.3.1
LI
O
N
S
H
E
A
D
W
E
L
C
O
M
E
C
E
N
T
E
R
BLDG. SIGNAGE & GRAPHICSDesign Intent4 October, 2012
Lionshead Welcome CenterTown of Vail
PROJECT
Greg Hall, Town of Vail
CLIENT CONTACT
HB, JM, DT
TEAM
Location Plan
Level 2
0.LP2
1112 Pearl Street Boulder, CO 80302TEL 303.447.8202 FAX 303.440.7069www.commarts-boulder.comwww.stantec.com
These drawings express visual design intent only. Final engineering, materials and fabrication shall remain the responsibility of the fabricator.
3.2.12.1
1.4s2.2
1.4s
2.4 1.4s2.6
3.2.1
2.3 3.2.12.5
1.2.22.12
2.32.13
2.22.15
1.5s2.17 1.5s2.19
1.5s2.16 1.5s2.18 1.52.20 1.5s2.22 1.5s2.23
2.32.25
1.52.21
2.32.10
2.1.12.9
1.42.8
1.42.7
2.42.14
1.5s2.24
Loc.
2.1
2.2
2.3
2.4
2.5
2.6
2.7
2.8
2.9
2.102.11
2.12
2.13
2.14
2.15
2.16
2.172.18
2.19
2.20
2.212.22
2.23
2.24
2.25
Type
3.2.1
1.4s
3.2.1
1.4s
3.2.1
1.4s
1.4
1.4
2.1.1
2.3
1.5s
1.2.2
2.3
2.42.2
1.5s
1.5s
1.5s
1.5s1.5
1.5
1.5s
1.5s1.5s
2.3
Message
a The Grand View
(Icons: Eco Transit, Restrooms)
d Vail Recreation District
Imagination Station
VRD Community Programming
p2
f Vail Recreation District
Imagination Station
VRD Community Programming
h Lionshead Village
(Icons: Information, ATM,
Restrooms, Lockers)
p2, Do You Rememeber....
a (Icon: Elevator)
d Lionshead Village
(Icons: Information, ATM,
Restrooms, Lockers)
p2, Do You Remember...p2, Do You Remember...
p2, Do You Remember...
p3 The Grand View
(Icons: Restrooms, Eco Transit)
p2 Vail Recreation District
Imagination Station
VRD Community Programming
p1 Drop-Off
Short Term Parking (Icon: Drop-Off)
Lobby/Street
Lionshead Village
(Icons: Info, Restrooms, Lockers, ATM)
In Case of Fire...
MECHANICAL (Braille)
Vail Recreation District
Imagination Station
VRD Community ProgrammingMaximum Occupancy 47
(Changeable Message Area)
(TBD, Hr.s of Operation)
204 (Braille)203 Mad Scientist Lab
205 (Braille)
206 (Braille)
(Restroom) UNISEX ADULT (Braille)
(Restroom) UNISEX CHILDREN (Braille)210 (Braille)
MECHANICAL (Braille)
STAIR (Braille)
Maximum Occupancy 41
1.5s2.11
Grayed back signs are not included in this contract.
Deleted
Deleted
LI
O
N
S
H
E
A
D
W
E
L
C
O
M
E
C
E
N
T
E
R
BLDG. SIGNAGE & GRAPHICSDesign Intent4 October, 2012
Lionshead Welcome CenterTown of Vail
PROJECT
Greg Hall, Town of Vail
CLIENT CONTACT
HB, JM, DT
TEAM
Location Plan
Level 3
0.LP3
1112 Pearl Street Boulder, CO 80302TEL 303.447.8202 FAX 303.440.7069www.commarts-boulder.comwww.stantec.com
These drawings express visual design intent only. Final engineering, materials and fabrication shall remain the responsibility of the fabricator.
Loc.
3.1
3.23.3
3.4
3.53.6
3.7
3.8
3.9
3.103.11
3.12
3.13
3.143.15
Type
3.2.3
1.3.22.3
2.1.1
1.41.4
1.2.3
1.3.1s
2.4
1.5
1.5
2.2
2.3
2.31.5s
Message
A k (Icons: Information, ATM)
B d (Icon: Eco Transit)
(Icons: Elevator, Restrooms, Information)
In Case of Fire...
p3 The Grand View
(Icons: Restrooms, Eco Transit)
p2 Vail Recreation District Imagination Station
VRD Community Programming
p1 Drop-Off
Short Term Parking
(Icon: Drop-Off)
Lobby/Street
Lionshead Village
(Icons: Info, Restrooms, Lockers, ATM)
p3, Do You Remember...p3, Do You Remember...
The Grand View
(Icon: Restrooms)
(Changeable Message Area)
(Women) WOMEN (Braille)
(Men) MEN (Braille)
The Grand View (Phone No.? web link?)
Maximum Occupancy 270
Maximum Occupancy 36STAIR (Braille)
A
B3.2.3 3.1
1.3.23.2
1.2.33.7 2.43.9
2.23.12
1.3.1s3.8
1.53.10
1.53.11
2.33.13
1.5s3.152.33.142.33.3
2.1.13.4
1.43.5
1.43.6
Grayed back signs are not included in this
contract.
Deleted
Deleted
Deleted
Deleted
LI
O
N
S
H
E
A
D
W
E
L
C
O
M
E
C
E
N
T
E
R
BLDG. SIGNAGE & GRAPHICSDesign Intent4 October, 2012
Lionshead Welcome CenterTown of Vail
PROJECT
Greg Hall, Town of Vail
CLIENT CONTACT
HB, JM, DT
TEAM
Location Photo
0.LP4
1112 Pearl Street Boulder, CO 80302TEL 303.447.8202 FAX 303.440.7069www.commarts-boulder.comwww.stantec.com
These drawings express visual design intent only. Final engineering, materials and fabrication shall remain the responsibility of the fabricator.
Flat mount Pedestrian Directionaland Small Level I.D.Sign Types 3.2.1 & 1.4s
Existing post mount Pedestrian DirectionalSign Type 3.2.4
Existing post mount Facility I.D.Sign Type 1.3.4
Entry I.D.South Entry 1Facility I.D. Sign Type 1.3.1
Level I.D.South Entry 1All levels, East sideSign Type 1.4
Entry I.D.South Entry 2Facility I.D.Sign Type 1.3.1
Project Entry I.D.South Entry 3Facility I.D.Sign Type 1.2.1
Blade Facility I.D.South Entry 4Facility I.D.Sign Type 1.3.2
LI
O
N
S
H
E
A
D
W
E
L
C
O
M
E
C
E
N
T
E
R
BLDG. SIGNAGE & GRAPHICSDesign Intent4 October, 2012
Lionshead Welcome CenterTown of Vail
PROJECT
Greg Hall, Town of Vail
CLIENT CONTACT
HB, JM, DT
TEAM
Secondary Project I.D.Level 1 North Elevation
1.1.2
1112 Pearl Street Boulder, CO 80302TEL 303.447.8202 FAX 303.440.7069www.commarts-boulder.comwww.stantec.com
These drawings express visual design intent only. Final engineering, materials and fabrication shall remain the responsibility of the fabricator.
Existing sconce fixtures
Bottom edge of concrete garage structure.
1/4" Thick plate stock sign panel. Panel has flush backer frame of 2" angle stock. 3" Fabricated cabinet at top, enclosed at sides, and open bottom face, houses LED illumination (Winona Winline LED 103W*) to wash front face, top to bottom. If multiple fixtures are required, hot or dark spots are not acceptable. Entire assembly painted M.1 (Corten) color.
Face has cut-out 1/4" plate metal letters, painted P.4 (White). Letters are mechanically fastened to sign panel. Sign panel is pinned 1/2" off wall surface by 2" Dia. cylinder clad studs on rear face, no visible fasteners on face.
Information icon mounted to wall adjacent to sign assembly. 1/4" plate stock face painted M.1 (Corten) color is separated from 2" thick fabricated rear cabinet, painted to match, by a 1/2" thick layer of M.2 (acrylic with frosted finish returns). LED illumination inside cabinet provides an edge glow through acrylic.
All conduit is to be concealed behind stone veneer.Venner to be replaced after installation.
Fabricator to review applicable Architectural Drawings (available on line from Owner) for existing wall construc-tion details to ensure appropriate anchor connections.
* http://www.winonalighting.com/products/winona_led/led_linear/103w
LIONSHEAD VILLAGE
Welcome Center
LIONSHEAD VILLAGE
Welcome Center
2"1/2"1/4"1/2"
3"
3"2"
Cabinet at top, LED fixture within. Fixture as far away from surface as possible
Letters fastened to face
Cylinder clad studs.Cylinders ground to fit stone surface
Stone wall surfaceSee Arch. Dwg’s for specific construction details
Stone veneer of wall to be patched appropri-ately after installation
1 Elevation
SCALE: 1/2"= 1'-0"
3 Section
SCALE: 3"= 1'-0"
2 Photo Composite
SCALE: NTS
-
1
Key Plan
Sign Section
1'-
6
"
1'
-
6
"
Panel Section Icon Section
5'-
3
"
AF
F
1'-
6
"
5'-8"
3"1'-6"
1/2"
LI
O
N
S
H
E
A
D
W
E
L
C
O
M
E
C
E
N
T
E
R
BLDG. SIGNAGE & GRAPHICSDesign Intent4 October, 2012
Lionshead Welcome CenterTown of Vail
PROJECT
Greg Hall, Town of Vail
CLIENT CONTACT
HB, JM, DT
TEAM
Transit Center I.D.North & South Elevations
1.1.3
1112 Pearl Street Boulder, CO 80302TEL 303.447.8202 FAX 303.440.7069www.commarts-boulder.comwww.stantec.com
These drawings express visual design intent only. Final engineering, materials and fabrication shall remain the responsibility of the fabricator.
2 Photo Composite
SCALE: NTSNorth Elevation
3 Elevation
SCALE: 1/2"= 1'-0"
1 Photo Composite
SCALE: NTSSouth Elevation
1/4" Thick plate stock sign panel. Panel has flush backer frame of 2" angle stock. 3" Fabricated cabinet at top, enclosed at sides, and open bottom face, houses LED illumination (Winona Winline LED 103W*) to wash front face, top to bottom. If multiple fixtures are required, hot or dark spots are not acceptable. to wash front face, top to bottom. Entire assembly painted M.1 (Corten) color.
Face has cut-out 1/4" plate metal letters, painted P.4 (White). Letters are mechanically fastened to sign panel. Sign panel is pinned 1/2" off wall surface by 2" Dia. cylinder clad studs on rear face, no visible fasteners on face.
Fabricator to review applicable Architectural Drawings (available on line from Owner) for existing wall construction details to ensure appropriate anchor connections.
* http://www.winonalighting.com/products/winona_led/led_linear/103w
Sign Type 1.3.3Single Pole mount blade icons Sign Type 1.3.2Wall mount blade icons
LIONSHEAD VILLAGE
Transit Center
LIONSHEAD VILLAGE
Transit Center
6'-0"
1'
-
8
"
5'-
2
"
LI
O
N
S
H
E
A
D
W
E
L
C
O
M
E
C
E
N
T
E
R
BLDG. SIGNAGE & GRAPHICSDesign Intent4 October, 2012
Lionshead Welcome CenterTown of Vail
PROJECT
Greg Hall, Town of Vail
CLIENT CONTACT
HB, JM, DT
TEAM
Project Entry I.D.South ElevationEntry 3
1.2.1
1112 Pearl Street Boulder, CO 80302TEL 303.447.8202 FAX 303.440.7069www.commarts-boulder.comwww.stantec.com
These drawings express visual design intent only. Final engineering, materials and fabrication shall remain the responsibility of the fabricator.
2 Elevation Detail
SCALE: 1/4"= 1'-0"South Entry 3
1 Perspective
SCALE: NTS
South Entry 1
South Entry 2 South Entry 3
Secondary Project I.D.
South Entry 4
3 Photo Composite
SCALE: NTS
Key Plan
Framed Sign1/4" Thick plate stock sign panel. Panel has flush backer frame of 3" angle stock. 4 1/2" Fabricated cabinet at top, enclosed at sides, and open at bottom, houses LED illumination (Winona Winline LED 103W*) to wash front face, top to bottom. If multiple fixtures are required, hot or dark spots are not acceptable.to wash front face, top to bottom. Entire assembly painted M.1 (Corten) color.
Face has cut-out 1/2" plate metal letters, painted P.4 (White). Letters are mechanically fastened to sign panel.
Sign panel is suspended from canopy surface by (3) 3" square tube stock supports and 1/2" thick base plate. Supports “pierce” top of frame and connect to a lateral support member. Entire support assembly painted P.3 (Black).
Fabricated IconInformation icon suspended adjacent to sign panel. 1/4" plate stock face painted M.1 (Corten) color is separated from 3" thick fabricated rear cabinet, painted to match, by a 1/2" thick layer of M.2 (acrylic with frosted finish returns). LED illumination inside cabinet provides an edge glow through acrylic. Icon base plate wraps canopy arm members.
Fabricator to review applicable Architectural Drawings (available on line from Owner) for existing canopy construction details to ensure appropriate anchor connections.
* http://www.winonalighting.com/products/winona_led/led_linear/103w
Plan
Section
Sign to align with
mullions in window
beyond.
Sign to align with
mullions in window
beyond.
LIONSHEAD VILLAGE
Welcome Center
LIONSHEAD VILLAGE
Welcome Center
6'-8"2'-0"
1'-
1
1
"
1'
-
2
"
±
VI
F
10
'
-
6
"
AF
F
10
'
-
6
"
AF
F
1'-6"
1'
-
0
"
3'
-
3
"
VIF
2'-
0
"
2'-8 1/4"
6'-8"
LI
O
N
S
H
E
A
D
W
E
L
C
O
M
E
C
E
N
T
E
R
BLDG. SIGNAGE & GRAPHICSDesign Intent4 October, 2012
Lionshead Welcome CenterTown of Vail
PROJECT
Greg Hall, Town of Vail
CLIENT CONTACT
HB, JM, DT
TEAM
Project Entry I.D.South ElevationEntry 3
1.2.1.2
1112 Pearl Street Boulder, CO 80302TEL 303.447.8202 FAX 303.440.7069www.commarts-boulder.comwww.stantec.com
These drawings express visual design intent only. Final engineering, materials and fabrication shall remain the responsibility of the fabricator.
2 Elevation Detail
SCALE: 3/4"= 1'-0"
3 Sections
SCALE: 1 1/2"= 1'-0"
1 Perspectives
SCALE: NTS
Rear view of framed sign panel
Sign is centered between canopy arms, icon is suspended below right pair of arms. Both align laterally.Boxed-in lateral support member on rear surface echoes light box on front.
Canopy underside
Base plate
Support arm
Light box
Lateral structure member
Support arm
Letters on face
Plate sign face
Angle stock frame
Canopy arm underside
Corten face
Lateral structure member
Fabricated icon cabinet
Plan
Section
Icon Section Sign Section
LIONSHEAD VILLAGE
Welcome Center
2'-8"
2'-8"
1'-9"3"
6'-8"
6'-8"
4
1
/
2
"
1'-
1
1
"
2'
-
0
"
5"
Eq.Eq.
1'-0"
1'-
0
"
7
1
/
2
"
2'-0"
1'-0"±
VIF
3
3
/
4
"
1'
-
0
"
1'-
4
"
±
VI
F
4 1
/
2
"
3"
LI
O
N
S
H
E
A
D
W
E
L
C
O
M
E
C
E
N
T
E
R
BLDG. SIGNAGE & GRAPHICSDesign Intent4 October, 2012
Lionshead Welcome CenterTown of Vail
PROJECT
Greg Hall, Town of Vail
CLIENT CONTACT
HB, JM, DT
TEAM
Entry I.D.Vail Recreatiion District
1.2.2
1112 Pearl Street Boulder, CO 80302TEL 303.447.8202 FAX 303.440.7069www.commarts-boulder.comwww.stantec.com
These drawings express visual design intent only. Final engineering, materials and fabrication shall remain the responsibility of the fabricator.
VAIL RECREATIONDISTRICT
2 Elevation Detail
SCALE: 1/4"= 1'-0"Level 2 North Entry
1 Photo Composite
SCALE: NTS
Key Plan
Sign positioned to clear door swing.
Power access from Mechanical room
Cabinet at top, LED fixture within
Masked and enamel painted graphics on face panel
Angle stock backer frame
Cylinder clad studs.Cylinders ground to fit stone surface
Stone wall surfaceSee Arch. Dwg’s for specific construction details
Stone veneer of wall to be patched appropri-ately after installation
2"1/2"1/4"3 Elevation
SCALE: 1"= 1'-0"
Section
Plan
1/4" Thick plate stock sign panel. Panel has flush backer frame of 2" angle stock. 3" Fabricated cabinet at top, enclosed at sides, and open bottom face, houses LED illumination (Winona Winline LED 103W*) to wash front face, top to bottom. Entire assembly painted M.1 (Corten) color.
Face has 2-color masked and painted graphics, color P.4 (White) with color P.3 (Black) drop shadow. (Note- drop shadow outlines to include the overprinting white shapes, so there is no offset edge under the white). Sign panel is pinned 1/2" off wall surface by 2" Dia. cylinder clad studs on rear face, no visible fasteners on face.
Fabricator to review applicable Architectural Drawings (available on line from Owner) for existing wall construction details to ensure appropriate anchor connections.
* http://www.winonalighting.com/products/winona_led/led_linear/103w
VAIL RECREATION
DISTRICT
VAIL RECREATION
DISTRICT
VAIL RECREATIONDISTRICT
2'-7"
3'
-
8
"
3"
3'-
0
"
3'-
8
"
2'-6"
3"2"
1/2"1/4"
LI
O
N
S
H
E
A
D
W
E
L
C
O
M
E
C
E
N
T
E
R
BLDG. SIGNAGE & GRAPHICSDesign Intent4 October, 2012
Lionshead Welcome CenterTown of Vail
PROJECT
Greg Hall, Town of Vail
CLIENT CONTACT
HB, JM, DT
TEAM
Entry I.D.Vail Community Room
1.2.3
1112 Pearl Street Boulder, CO 80302TEL 303.447.8202 FAX 303.440.7069www.commarts-boulder.comwww.stantec.com
These drawings express visual design intent only. Final engineering, materials and fabrication shall remain the responsibility of the fabricator.
2 Elevation Detail
SCALE: 1/4"= 1'-0"Level 3 North Entry
3 Elevation
SCALE: 1"= 1'-0"
1 Photo Composite
SCALE: NTSLevel 3 North Entry
Key Plan Plan
Power access in JC
1/4" Thick plate stock sign panel. Panel has flush backer frame of 2" angle stock. 3" Fabricated cabinet at top, enclosed at sides, and open bottom face, houses LED illumina-tion (Winona Winline LED 103W*) to wash front face, top to bottom. Entire assembly painted M.1 (Corten) color.
Face has 2-color masked and painted graphics, color P.4 (White) with color P.3 (Black) drop shadow. (Note- drop shadow outlines to include the overprinting white shapes, so there is no offset edge under the white). Sign panel is pinned 1/2" off wood wall surface by 2" Dia. cylinder clad studs on rear face, no visible fasteners on face.
Fabricator to review applicable Architectural Drawings (available on line from Owner) for existing wall construction details to ensure appropriate anchor connections.
* http://www.winonalighting.com/products/winona_led/led_linear/103w
Sign Type 1.3.1s
The Grand ViewThe Grand View
5'
-
4
"
AF
F
3"2"
1/2"
3"
1'-
3
"
4'-2"
LI
O
N
S
H
E
A
D
W
E
L
C
O
M
E
C
E
N
T
E
R
BLDG. SIGNAGE & GRAPHICSDesign Intent4 October, 2012
Lionshead Welcome CenterTown of Vail
PROJECT
Greg Hall, Town of Vail
CLIENT CONTACT
HB, JM, DT
TEAM
Entry I.D.West ElevationGarage Entry
1.2.4
1112 Pearl Street Boulder, CO 80302TEL 303.447.8202 FAX 303.440.7069www.commarts-boulder.comwww.stantec.com
These drawings express visual design intent only. Final engineering, materials and fabrication shall remain the responsibility of the fabricator.
2 Elevation Detail
SCALE: 1/4"= 1'-0"West Garage Entry
3 Elevation
SCALE: 3/4"= 1'-0"Information Panel
1 Photo Composite
SCALE: NTS
Key Plan
Plan
Drop Off Only
Short Term Parking
1/4" Thick plate stock sign panel. Panel has flush backer frame of 3" angle stock. Entire assembly painted M.1 (Corten) color. Sign panel is externally illuminated by existing light fixture above.
Face has cut-out 1/4" plate metal letters, painted P.4 (White). Letters are mechanically fastened to sign panel. Sign panel is fastened to wall surface by 2" Dia. cylinder clad studs on rear face, no visible fasteners on face.
Information icon mounted to wall adjacent to sign assembly. 3/8" plate stock face painted M.1 (Corten) color is separated from 3" thick fabricated rear cabinet, painted to match, by a 3/4" thick layer of M.2 (acrylic with frosted finish returns). LED illumination inside cabinet provides an edge glow through acrylic.
1/2" Plate stock sign panel pinned off curved entry lintel. Channel stock tracks hold (2) changeable message panels, all painted P.3 (Black). 2-Layer icon panels mechanically fastened to sign panel at right, front layer painted P.1 (Dk. Lionshead Red), rear layer painted P.3 (Black).
Fabricator to review applicable Architectural Drawings (available on line from Owner) for existing entry construction details to ensure appropriate anchor connections.
Angled bracket clips on rear side of info panel connect to rolled entry beam.
Two layer icon panels fastened to front face.
Sign Type 1.7Clearance I.D.
Sections
Channel tracks
Changeable panel
2-Layer icons
Welcome Center
LIONSHEAD VILLAGE
Drop Off Only
Short Term Parking
-
B
-
A
A B
4'-0"
4'-0"
2'-
0
"
1'-
1
0
"
Pa
n
e
l
11
"
4"
2'-
2
"
To
t
a
l
10'-0"
2'-
6
"
LI
O
N
S
H
E
A
D
W
E
L
C
O
M
E
C
E
N
T
E
R
BLDG. SIGNAGE & GRAPHICSDesign Intent4 October, 2012
Lionshead Welcome CenterTown of Vail
PROJECT
Greg Hall, Town of Vail
CLIENT CONTACT
HB, JM, DT
TEAM
Entry I.D.Garage EntryFreestanding Sign
1.2.5
1112 Pearl Street Boulder, CO 80302TEL 303.447.8202 FAX 303.440.7069www.commarts-boulder.comwww.stantec.com
These drawings express visual design intent only. Final engineering, materials and fabrication shall remain the responsibility of the fabricator.
3 Photo Composite
SCALE: NTSE. LionsHead Cir.
3 Perspective
SCALE: NTS
2 Plan Detail
SCALE: 1/16" = 1' - 0"
1 Elevation
SCALE: 1/2" = 1'- 0"
2" Thick fabricated sign cabinet with 1/4" plate stock faces. 4" Fabricated light coves at top, both sides, enclosed at sides, and open bottom face, houses LED illumination (Winona Winline LED 103W*) to wash front face, top to bottom. If multiple fixtures are required, hot or dark spots are not acceptable. Entire assembly painted M.1 (Corten) color.
Sign face has cut-out 1/4" plate metal letters, painted P.4 (White). Letters are mechanically fastened to sign panel. Face has 1/2" thick plate stock icon disk, painted P.4 (White) with 1/4" cut out arrow, painted P.3 (Black), both mechanically fastened. All white graphics to have V.1 (Reflective White vinyl) faces.
Sign cabinet supported by (3) 2" square connection blocks. Connection blocks connect to 1/2" plate stock collars that wrap wood posts. Connection blocks and collars painted P.3 (Black).
10" Square rough sawn wood posts. Species and finish to match those on building (XXX). Posts to have foundation and protection from elelments as required for conditions.
Fabricator to review applicable Architectural Drawings (available on line from Owner) for existing entry construction details to ensure appropriate anchor connections.* http://www.winonalighting.com/products/winona_led/led_linear/103w
Sign
Light fixture caisson
Stone pedestal wall terminus
Stone wall
Limited use message positioned at top of forward corner of sign face, Welcome Center message gets second billing.
Drop-Off & Short Term ParkingOnly
Drop-Off & Short Term ParkingOnly
Plan
Side B message
Section
8'-8"
Total
6'-6"
Sign Panel
10"
Posts
11"
Collars
11
"
Co
l
l
a
r
s
4"Lig
h
t
Co
v
e
4"
Ca
b
i
n
e
t
2"
Co
r
e
c
a
b
i
n
e
t
4"Light Cove 2"4"Light Cove
4"
6"
Cu
r
b
3'-
7
"
Po
s
t
s
2'-
8
"
Si
g
n
C
a
b
i
n
e
t
1'-6"
1'
-
0
"
to
C
u
r
b
2"
LI
O
N
S
H
E
A
D
W
E
L
C
O
M
E
C
E
N
T
E
R
BLDG. SIGNAGE & GRAPHICSDesign Intent4 October, 2012
Lionshead Welcome CenterTown of Vail
PROJECT
Greg Hall, Town of Vail
CLIENT CONTACT
HB, JM, DT
TEAM
Facility I.D.Flat Mount PanelsEntry 1
1.3.1
1112 Pearl Street Boulder, CO 80302TEL 303.447.8202 FAX 303.440.7069www.commarts-boulder.comwww.stantec.com
These drawings express visual design intent only. Final engineering, materials and fabrication shall remain the responsibility of the fabricator.
1 Elevation Detail
SCALE: 1/4"= 1'-0"South Entry 1
2 Elevation
SCALE: 1"= 1'-0"
3 Photo Composite
SCALE: NTS
South Entry 1
South Entry 2 South Entry 3
Secondary Project I.D.
South Entry 4Key Plan
Rear face R= 2 5/8"
Inset face R= 2"
6 Sept Add’n
4 Oct Change
1/4" Plate stock icon panel inset faces, painted P.1 (Dk. Lionshead Red). Inset faces fastened to rear faces with exposed vandal resistant fasteners, painted to match field. 1/4" Rear face and 1 1/2" flush angle stock backer frame painted P.3 (Black).
Icon graphics are masked and painted P.4 (White).
Icon assemblies individually pinned 1 1/2" apart and 1/2" off stone surface with 2" Dia. cylinder clad studs, (2) per panel, painted P.3 (Black). Cylinders ground as required to fit stone.
Fabricator to review applicable Architectural Drawings (available on line from Owner) for existing wall construction details to ensure appropriate anchor connections.
Section
1/2"
1 1/2"1/4"1/4"
2" Total Width
1'-
1
"
In
s
e
t
F
a
c
e
1'-
2
"
Re
a
r
F
a
c
e
1'-
1
0
"
Re
a
r
F
a
c
e
1'-
8
1
/
2
"
In
s
e
t
F
a
c
e
1 1/2"1 1/2"1'-2"1'-2"1'-2"
Sign Type 1.4Level I.D.
LI
O
N
S
H
E
A
D
W
E
L
C
O
M
E
C
E
N
T
E
R
BLDG. SIGNAGE & GRAPHICSDesign Intent4 October, 2012
Lionshead Welcome CenterTown of Vail
PROJECT
Greg Hall, Town of Vail
CLIENT CONTACT
HB, JM, DT
TEAM
Facility I.D.Flat Mount PanelsEntry 2
1.3.1.2
1112 Pearl Street Boulder, CO 80302TEL 303.447.8202 FAX 303.440.7069www.commarts-boulder.comwww.stantec.com
These drawings express visual design intent only. Final engineering, materials and fabrication shall remain the responsibility of the fabricator.
1 Elevation Detail
SCALE: 1/4"= 1'-0"South Entry 2
2 Elevation
SCALE: 1"= 1'-0"
South Entry 1
South Entry 2 South Entry 3
Secondary Project I.D.
South Entry 4
3 Photo Composite
SCALE: NTS
Key Plan
1/4" Plate stock icon panel inset faces, painted P.1 (Dk. Lionshead Red). Inset faces fastened to rear face with exposed vandal resistant fasteners, painted to match field. 1/4" Rear face and 1 1/2" flush angle stock backer frame painted P.3 (Black).
Icon graphics are masked and painted P.3 (White).
Icon assemblies individually pinned 1 1/2" apart and 1/2" off stone surface with 2" Dia. cylinder clad studs, (2) per panel, painted P.3 (Black). Cylinders ground as required to fit stone.
Fabricator to review applicable Architectural Drawings (available on line from Owner) for existing wall construction details to ensure appropriate anchor connections.
Rear face R= 2 5/8"
Inset face R= 2"
5/8"
1 1/2"
Section
1/2"
1 1/2"1/4"1/4"
2" Total Width
3"
6'-4"
1'
-
2
"
1'
-
1
"
In
s
e
t
F
a
c
e
1'-
2
"
Re
a
r
F
a
c
e
5'-1/2"
LI
O
N
S
H
E
A
D
W
E
L
C
O
M
E
C
E
N
T
E
R
BLDG. SIGNAGE & GRAPHICSDesign Intent4 October, 2012
Lionshead Welcome CenterTown of Vail
PROJECT
Greg Hall, Town of Vail
CLIENT CONTACT
HB, JM, DT
TEAM
Facility I.D.Small Flat Mount Panels3rd Level North Entry
1.3.1.s
1112 Pearl Street Boulder, CO 80302TEL 303.447.8202 FAX 303.440.7069www.commarts-boulder.comwww.stantec.com
These drawings express visual design intent only. Final engineering, materials and fabrication shall remain the responsibility of the fabricator.
1 Photo Composite
SCALE: NTS
2 Elevation Detail
SCALE: 3/8"= 1'-0"3rd Level North Entry
3 Elevation
SCALE: 1"= 1'-0"
Sign to align with top of Sign Type 1.2.3, Grand View I.D.
Section
1.3.1s Is a smaller version of Sign Type 1.3.1
1/4" Plate stock icon panel inset faces, painted P.1 (Dk. Lionshead Red). Inset faces fastened to rear facew with exposed vandal resistant fasteners, painted to match field. 1/4" Rear face and 1 1/2" flush angle stock backer frame painted P.3 (Black).
Icon graphics are masked and painted P.4 (White).
Icon assembly pinned 1/2" off stone surface with 2" Dia. cylinder clad studs, (2) per panel, painted P.3 (Black).
Fabricator to review applicable Architectural Drawings (available on line from Owner) for existing wall construction details to ensure appropriate anchor connections.
1/2"
1 1/2"
1/4"1/4"
9 1
/
8
"
10
"
10"
5'
-
4
"
1'
-
6
"
6'
-
0
"
LI
O
N
S
H
E
A
D
W
E
L
C
O
M
E
C
E
N
T
E
R
BLDG. SIGNAGE & GRAPHICSDesign Intent4 October, 2012
Lionshead Welcome CenterTown of Vail
PROJECT
Greg Hall, Town of Vail
CLIENT CONTACT
HB, JM, DT
TEAM
Facility I.D.Blade Mount Icon PanelsEntry 4
1.3.2
1112 Pearl Street Boulder, CO 80302TEL 303.447.8202 FAX 303.440.7069www.commarts-boulder.comwww.stantec.com
These drawings express visual design intent only. Final engineering, materials and fabrication shall remain the responsibility of the fabricator.
2 Side Elevation
SCALE: 1/4"= 1'-0"South Entry 3
1 Plan
SCALE: 1/4"= 1'-0"South Entry 3
3 Elevation
SCALE: 1/4"= 1'-0"
2-Sided cabinet construction blade mount icon sign.
3" Thick fabricated icon shapes are supported by 6" high bracket arms, same thickness to 1/2" thick mounting plate. Mounting Plate to match height of icon(s). Entire assembly painted P.3 (Black). Sign fastened to stone wall surface with exposed 3/4" hex head fasteners, painted to match field.
Both faces of icon shapes have inset 1/4" plate stock panels, painted P.1 (Dk. Lionshead Red). Inset faces fastened to rear facew with exposed countersunk vandal resistant fasteners, painted to match field.
Faces of inset panels have masked and enamel painted graphics, P.4 (White).
Fabricator to review applicable Architec-tural Drawings (available on line from Owner) for existing wall construction details to ensure appropriate anchor connections.
Key Plan
1'-2"
1 1/2"
1/2"3"
9"
3 1/2"
4 Photo Composite
SCALE: NTS
2'-
5
1
/
2
"
1'
-
2
"
1'-
2
"
2'
-
5
1
/
2
"
10
"
1 1
/
2
"
LI
O
N
S
H
E
A
D
W
E
L
C
O
M
E
C
E
N
T
E
R
BLDG. SIGNAGE & GRAPHICSDesign Intent4 October, 2012
Lionshead Welcome CenterTown of Vail
PROJECT
Greg Hall, Town of Vail
CLIENT CONTACT
HB, JM, DT
TEAM
Facility I.D.-Blade Mount Icon PanelsThird Level
1.3.2.2
1112 Pearl Street Boulder, CO 80302TEL 303.447.8202 FAX 303.440.7069www.commarts-boulder.comwww.stantec.com
These drawings express visual design intent only. Final engineering, materials and fabrication shall remain the responsibility of the fabricator.
1 Elevation Detail
SCALE: 1/4"= 1'-0"Level 3 Northeast Elev.
2 Photo Composite
SCALE: NTS
Key Plan
Side Elevation VAIL
Community Room
2-Sided cabinet construction blade mount icon sign.
3" Thick fabricated icon shapes are supported by 6" high bracket arms, same thickness to 1/2" thick mounting plate. Mounting Plate to match height of icon(s). Entire assembly painted P.3 (Black). Sign fastened to stone wall surface with exposed 3/4" hex head fasteners, painted to match field.
Both faces of icon shapes have inset 1/4" plate stock panels, painted P.1 (Dk. Lionshead Red). Inset faces fastened to rear faces with exposed vandal resistant fasteners, painted to match field.
Faces of inset panels have masked and enamel painted graphics, P.4 (White).
Fabricator to review applicable Architectural Drawings (available on line from Owner) for existing canopy construction details to ensure appropriate anchor connections.
Facility I.D.Sign Type 1.2.3
1'-
2
"
3'
-
9
"
3'
-
9
"
9"
LI
O
N
S
H
E
A
D
W
E
L
C
O
M
E
C
E
N
T
E
R
BLDG. SIGNAGE & GRAPHICSDesign Intent4 October, 2012
Lionshead Welcome CenterTown of Vail
PROJECT
Greg Hall, Town of Vail
CLIENT CONTACT
HB, JM, DT
TEAM
Facility I.D.-Blade Mount Icon PanelsInterior Variation
1.3.2.3
1112 Pearl Street Boulder, CO 80302TEL 303.447.8202 FAX 303.440.7069www.commarts-boulder.comwww.stantec.com
These drawings express visual design intent only. Final engineering, materials and fabrication shall remain the responsibility of the fabricator.
1 Elevation Detail
SCALE: 3/8"= 1'-0"Level 1 East Interior Elevation
2 Photo Reference
SCALE: NTS
Header wall to have wood trim at bottom, code requ’d EXIT sign and access panel for fireplace damper.
Sign assembly to fasten to side of fireplace
2-Sided cabinet construction blade mount icon sign.
3" Thick fabricated icon shapes are supported by 6" high bracket arms, same thickness to 1/2" thick mounting plate. Mounting Plate to match height of icon(s). Entire assembly painted P.3 (Black).
Both faces of icon shapes have inset 1/4" plate stock panels, painted P.1 (Dk. Lionshead Red). Inset faces fastened to rear shapes with exposed countersunk vandal resistant fasteners, painted to match field.
Faces of inset panels have masked and enamel painted graphics, P.4 (White).
Fabricator to review applicable Architec-tural Drawings (available on line from Owner) for existing wall construction details to ensure appropriate anchor connections.
Key Plan
Side Elevation
Side A Side B
1'-
2
"
1 1
/
2
"
2'
-
5
1
/
2
"
2'
-
5
1
/
2
"
9"
LI
O
N
S
H
E
A
D
W
E
L
C
O
M
E
C
E
N
T
E
R
BLDG. SIGNAGE & GRAPHICSDesign Intent4 October, 2012
Lionshead Welcome CenterTown of Vail
PROJECT
Greg Hall, Town of Vail
CLIENT CONTACT
HB, JM, DT
TEAM
Facility I.D.-Blade Mount Icon PanelsSingle Tapering Pole Assembly
1.3.3
1112 Pearl Street Boulder, CO 80302TEL 303.447.8202 FAX 303.440.7069www.commarts-boulder.comwww.stantec.com
These drawings express visual design intent only. Final engineering, materials and fabrication shall remain the responsibility of the fabricator.
2 Elevation
SCALE: 3/8"= 1'-0"
1 Photo Composite
SCALE: NTSTransit Center, South Elevation
Plan1.3.3
2-Sided cabinet construction icon signs fastened to a clustered pole assembly.
3" Thick fabricated icon shapes are supported by 10" high bracket arms, same thickness that fasten between the members of the clustered pole assembly. Entire assembly painted P.3 (Black).
Both faces of icon shapes have inset 1/4" plate stock panels, secured with mechanical fasteners, painted P.1 (Dk. Lionshead Red).
Faces of inset panels have masked and enamel painted graphics, P.4 (White).
(4) or (1) Tapering poles, painted P.3 (Black) secured together by (4) 1/4" plate stock bands, painted P.2 (Lionshead Anthracite). Second band from the bottom has cut-out 1/4" logo backer plate, painted P.3 (Black), with 1/4" raised logo, P.2 (Lionshead Anthracite), 2-sides. Domed cap at top.
Precast colored concrete base.
Ordinarily, a 14' pole mount assembly would
look like this. The particular location where
this sign occurs has a concrete abuttment,
requiring a “sawed-off” variation, at right.
2'-0"
1'-
4
"
1'-
3
"
2'-
5
1
/
2
"
14
'
-
0
"
“Sawed-off” variation at
Transit Center
LI
O
N
S
H
E
A
D
W
E
L
C
O
M
E
C
E
N
T
E
R
BLDG. SIGNAGE & GRAPHICSDesign Intent4 October, 2012
Lionshead Welcome CenterTown of Vail
PROJECT
Greg Hall, Town of Vail
CLIENT CONTACT
HB, JM, DT
TEAM
Facility I.D.-Blade Mount Icon PanelsExisting Pole Assembly
1.3.4
1112 Pearl Street Boulder, CO 80302TEL 303.447.8202 FAX 303.440.7069www.commarts-boulder.comwww.stantec.com
These drawings express visual design intent only. Final engineering, materials and fabrication shall remain the responsibility of the fabricator.
2-Sided cabinet construction icon signs fastened to existing posts.
3" Thick fabricated icon shapes are supported by 10" high bracket arms, same thickness that fasten to a compression cuff that secures to pole. Entire assembly painted P.3 (Black).
In each case, pole Dia. will vary, VIF each location for compression cuff.
Both faces of icon shapes have inset 1/4" plate stock panels, secured with mechanical fasteners, painted P.1 (Dk. Lionshead Red).
Faces of inset panels have masked and enamel painted graphics, P.4 (White).
Existing post is open at top. Sign Fabricator to add a domed cap to existing post.
1 Elevation
SCALE: 1/2"= 1'-0"
Sign Type 1.3.4xExisting Post Blade Mount Facility I.D.
1'-
2
"
10
'
-
6
"
13
'
-
0
"
±
1'-
3
"
LI
O
N
S
H
E
A
D
W
E
L
C
O
M
E
C
E
N
T
E
R
BLDG. SIGNAGE & GRAPHICSDesign Intent4 October, 2012
Lionshead Welcome CenterTown of Vail
PROJECT
Greg Hall, Town of Vail
CLIENT CONTACT
HB, JM, DT
TEAM
Level I.D.
1.4
1112 Pearl Street Boulder, CO 80302TEL 303.447.8202 FAX 303.440.7069www.commarts-boulder.comwww.stantec.com
These drawings express visual design intent only. Final engineering, materials and fabrication shall remain the responsibility of the fabricator.
1 Elevation Detail
SCALE: 3/8"= 1'-0"Level 1 East Interior Elevation
2 Elevation
SCALE: 1 1/2"= 1'-0"
3 Photo Composite
SCALE: NTS
Section
1/2"
1 1/2"1/2"
1/4" Plate stock icon panel inset faces, painted P.1 (Dk. Lionshead Red). Inset faces fastened to rear faces with exposed countersunk vandal resistant fasteners, painted to match field. 1/4" rear face and 2" flush angle stock backer frame, painted P.3 (Black).
Icon graphics are masked and painted P.4 (White).
Icon assemblies individually pinned 1/2" off stone surface with 2" Dia. cylinder clad studs, (2) per panel, painted P.3 (Black). Cylinders ground as required to fit stone.
Fabricator to review applicable Architectural Drawings (available on line from Owner) for existing wall construction details to ensure appropriate anchor connections.
Signs located inside the garage, viewed when exiting the garages, include the “Do you Remem-ber....” message.
Sign Type 1.3.1Facility I.D.Sign Type 1.4.1Level I.D.
Signs located on the exterior of the garages, viewed from the street, do not include that message. (This variation is currently used only at theVail Village parking structure)
1'-
8
1
/
2
"
In
s
e
t
F
a
c
e
1'-
1
0
"
Re
a
r
F
a
c
e
1'-10"
LI
O
N
S
H
E
A
D
W
E
L
C
O
M
E
C
E
N
T
E
R
BLDG. SIGNAGE & GRAPHICSDesign Intent4 October, 2012
Lionshead Welcome CenterTown of Vail
PROJECT
Greg Hall, Town of Vail
CLIENT CONTACT
HB, JM, DT
TEAM
Small Level I.D.
1.4s
1112 Pearl Street Boulder, CO 80302TEL 303.447.8202 FAX 303.440.7069www.commarts-boulder.comwww.stantec.com
These drawings express visual design intent only. Final engineering, materials and fabrication shall remain the responsibility of the fabricator.
Vail Recreation DistrictImagination StationVRD Community Programming
LionsHead VillageWelcome Center
The Grand ViewTransit Center
LionsHead VillageWelcome Center
LionsHead VillageWelcome Center
LionsHead VillageWelcome Center
2 Elevation Detail
SCALE: 3/8"= 1'-0"
1 Photo Composite
SCALE: NTSDrop-Off Area, Level 1
3 Photo Composite
SCALE: NTSLevel 2 Core Entry
4 Photo Composite
SCALE: NTSLevel 2 Stair
Level 1 Core Entry Level 2Core Entry Level 2Stairwell EntrySouth Wall
Level 2Stairwell EntryNorth Wall
1 Elevation
SCALE: 1"= 1'-0"Section
1/2"1 1/2"
1/4"1/4"
9 1
/
4
"
10
"
Signs viewed when exiting the garages include the “Do you Remember....” message.
Backer frame is to be notched to accept the sign below. Signs located on the exterior of the garages, viewed from the street, do not include that message.
When this sign type appears as a modifier to
another sign (Sign Type 3.2.3),
this smaller size is to be used: 10".
1/4" Plate stock icon panel inset faces, painted
P.1 (Dk. Lionshead Red). Inset faces fastened
to rear faces with countersunk vandal reistant
fasteners, painted to match field. 1/4" Rear face
and 1 1/2" flush angle stock backer frame
painted P.3 (Black). Backer frame is to be
notched to accept the sign below.
Icon graphics are masked and painted P.4
(White).
Icon assemblies individually pinned 1/2" off
stone surface with 2" Dia. cylinder clad studs,
(2) per panel, painted P.3 (Black). Cylinders
ground as required to fit stone.
Fabricator to review applicable Architectural
Drawings (available on line from Owner) for
existing wall construction details to ensure
appropriate anchor connections.
See note at right
10"
LI
O
N
S
H
E
A
D
W
E
L
C
O
M
E
C
E
N
T
E
R
BLDG. SIGNAGE & GRAPHICSDesign Intent4 October, 2012
Lionshead Welcome CenterTown of Vail
PROJECT
Greg Hall, Town of Vail
CLIENT CONTACT
HB, JM, DT
TEAM
Garage Entry Clearance I.D.
1.7
1112 Pearl Street Boulder, CO 80302TEL 303.447.8202 FAX 303.440.7069www.commarts-boulder.comwww.stantec.com
These drawings express visual design intent only. Final engineering, materials and fabrication shall remain the responsibility of the fabricator.
Sign Type 1.2.4
Garage Entry I.D.
1 Elevation Detail
SCALE: 1/4"= 1'-0"West Elevation
Drop Off Only
30 Min. Parking
Welcome Center
LIONSHEAD VILLAGE
4" Dia. thin wall aluminum tube suspended from 1/8" braided stainless steel aircraft cable.
Tube is painted P.1 (Dk Lionshead Red) vinyl and graphics are V.1 (Reflective White).
7'-
5
"
8'-0"
2 Photo Composite
SCALE: NTS
LI
O
N
S
H
E
A
D
W
E
L
C
O
M
E
C
E
N
T
E
R
BLDG. SIGNAGE & GRAPHICSDesign Intent4 October, 2012
Lionshead Welcome CenterTown of Vail
PROJECT
Greg Hall, Town of Vail
CLIENT CONTACT
HB, JM, DT
TEAM
Directory-Elevator Lobby
2.1.1
1112 Pearl Street Boulder, CO 80302TEL 303.447.8202 FAX 303.440.7069www.commarts-boulder.comwww.stantec.com
These drawings express visual design intent only. Final engineering, materials and fabrication shall remain the responsibility of the fabricator.
1 Elevation Detail
SCALE: 3/8"= 1'-0"
2 Layouts
SCALE: 1"= 1'-0"
3 Photo Composite
SCALE: NTS
Section
2nd Surface Vinyl Graphics
1/4" Plate metal sign backer panel pinned 1/4" off
(smooth) wall surface. Panel has M.1 (Corten) finish,
specific floor band painted P.1 (Dk. Lionshead Red).
Returns painted P.1 (Dk. Lionshead Red) or M.1
(Corten), depending upon its adjacent face color.
1/4" x 11/2" Attachment straps at top and bottom. Straps
painted P.3 (Black). 1/2" Dia. vandal resistant head
fasteners, painted to match field.
Attachment straps secure .060 non-glare acrylic sheet,
same size as sign backer panel. Acrylic has second
surface graphics, V.3 (Matte White).
1'-6"
2'
-
6
"
Street Level Garage Level 1 Level 2 Level 3
5'-
9
"
AF
F
1'-6"
2'-
6
"
LI
O
N
S
H
E
A
D
W
E
L
C
O
M
E
C
E
N
T
E
R
BLDG. SIGNAGE & GRAPHICSDesign Intent4 October, 2012
Lionshead Welcome CenterTown of Vail
PROJECT
Greg Hall, Town of Vail
CLIENT CONTACT
HB, JM, DT
TEAM
Directory-Elevator Cabs
2.1.2
1112 Pearl Street Boulder, CO 80302TEL 303.447.8202 FAX 303.440.7069www.commarts-boulder.comwww.stantec.com
These drawings express visual design intent only. Final engineering, materials and fabrication shall remain the responsibility of the fabricator.
1 Elevation Detail
SCALE: 3/8"= 1'-0"
2 Elevation Section
SCALE: Half Size
3 Photo Composite
SCALE: NTS
321L
Lobby/Street
The Grand View
Vail Recreation DistrictImagination StationVRD Community Programming
Drop-OffShort Term Parking
Lionshead Village
2nd Surface Vinyl Graphics1/4" Plate aluminum sign backer panel adhered (mechanically fastened if possible) to cab wall surface. Panel painted P.1 (Dk. Lionshead Red), Returns painted P.1 (Dk. Lionshead Red) or P.3 (Black), depending upon its adjacent face color.
1/4" x 1" Attachment straps at top and bottom. Straps painted P.3 (Black). 1/2" Dia. vandal resistant head fasteners, painted to match field.
Attachment straps secure .060 non-glare acrylic sheet, same size as sign backer panel. Acrylic has second surface graphics, V.3 (Matte White).
Vandal resistant fasteners
1/8" Attachment strap
.060 Non-glare acrylic,
2nd surface vinyl graphics
1/4" Backer panel
Cab wall surface
8"
8"
10"
1"1"
1"
LI
O
N
S
H
E
A
D
W
E
L
C
O
M
E
C
E
N
T
E
R
BLDG. SIGNAGE & GRAPHICSDesign Intent4 October, 2012
Lionshead Welcome CenterTown of Vail
PROJECT
Greg Hall, Town of Vail
CLIENT CONTACT
HB, JM, DT
TEAM
Entry Door Graphics
Glass Doors
2.2
1112 Pearl Street Boulder, CO 80302TEL 303.447.8202 FAX 303.440.7069www.commarts-boulder.comwww.stantec.com
These drawings express visual design intent only. Final engineering, materials and fabrication shall remain the responsibility of the fabricator.
1 Elevation
SCALE: 3/8"= 1'-0"South Entry 2 (“Cat Door”)Street Level Elevator Lobby
2 Elevation
SCALE: 3/8"= 1'-0"South Entry 2Vestibule Entry
3 Elevation
SCALE: 3/8"= 1'-0"South Entry 3Street Level Primary Entry
4 Elevation
SCALE: 3/8"= 1'-0"South Entry 4Street Level Restroom Entry
5 Elevation
SCALE: 3/8"= 1'-0"North Entry, 3rd LevelVestibule Entry
2
1
3 4
5
South Entry 2
South Entry 3
3rd Level North Vestibule Entry
South Entry 4
Currently reads:
Elevators & ADA Access
Enter Here
Automatic door decal
Currently reads:Currently reads:
Diagrammatic Key Plan
Restrooms
& Lockers
Restrooms
& Lockers
TheGrand View
LIONSHEAD VILLAGE
Welcome Center
LIONSHEAD VILLAGE
Welcome Center
LIONSHEAD VILLAGEWelcome Center
LIONSHEAD VILLAGEWelcome Center
Elevators
& ADA Access
to Parking
Messages to be second surface machine-cut vinyl, V.3 (Frosted Crystal).
Messages in Sign Package typeface are to replace any existing messages.
LI
O
N
S
H
E
A
D
W
E
L
C
O
M
E
C
E
N
T
E
R
BLDG. SIGNAGE & GRAPHICSDesign Intent4 October, 2012
Lionshead Welcome CenterTown of Vail
PROJECT
Greg Hall, Town of Vail
CLIENT CONTACT
HB, JM, DT
TEAM
Entry Door Graphics
50th Anniversary
Temporary Patches
2.2c
1112 Pearl Street Boulder, CO 80302TEL 303.447.8202 FAX 303.440.7069www.commarts-boulder.comwww.stantec.com
These drawings express visual design intent only. Final engineering, materials and fabrication shall remain the responsibility of the fabricator.
1 Elevation
SCALE: 3/8"= 1'-0"South Entry 2 (“Cat Door”)Street Level Elevator Lobby
2 Elevation
SCALE: 3/8"= 1'-0"South Entry 2Vestibule Entry
3 Elevation
SCALE: 3/8"= 1'-0"South Entry 3Street Level Primary Entry
4 Elevation
SCALE: 3/8"= 1'-0"South Entry 4Street Level Restroom Entry
5 Elevation
SCALE: 3/8"= 1'-0"North Entry, 3rd LevelVestibule Entry
2
1
3 4
5
South Entry 2
South Entry 3
3rd Level North Vestibule Entry
South Entry 4
2-Sided full color digitally
printed logo on white vinyl applied second surface
Diagrammatic Key Plan
Restrooms
Public Lockers
Restrooms
& Lockers
TheGrand View
LIONSHEAD VILLAGE
Welcome Center
LIONSHEAD VILLAGE
Welcome Center
LIONSHEAD VILLAGEWelcome Center
LIONSHEAD VILLAGEWelcome Center
Elevators
& ADA Access
to Parking
Temporary logo decals applied to all glass entry doors: street level and Grand View room.
8 1/2"
1'
-
0
"
4"
LI
O
N
S
H
E
A
D
W
E
L
C
O
M
E
C
E
N
T
E
R
BLDG. SIGNAGE & GRAPHICSDesign Intent4 October, 2012
Lionshead Welcome CenterTown of Vail
PROJECT
Greg Hall, Town of Vail
CLIENT CONTACT
HB, JM, DT
TEAM
VehicularDirectionalSingle Post
3.1.1
1112 Pearl Street Boulder, CO 80302TEL 303.447.8202 FAX 303.440.7069www.commarts-boulder.comwww.stantec.com
These drawings express visual design intent only. Final engineering, materials and fabrication shall remain the responsibility of the fabricator.
2 Elevation
SCALE: 3/8" = 1'-0"
1 Photo Composite
SCALE: NTS
Sign Type 1.2.5-Freestanding Sign
Plate metal brand detail, every pole at 5'-0" AFF.
Sign Type 1.2.4-Threshold Sign(not visible here)
CDOT Class III sign assembly.
6'-0" x 6'-0" x 1/4" Aluminum sign panel. Face painted P.1 (Dk Lionshead Red) with V.1 (Reflective White) graphics.
Sign supported by single tapering post assembly. Post, painted P.3 (Black) tapers from 8" at bottom to 4" at top. Post has (5) 6" bands of 1/2" plate stock, painted P.2 (Lionshead Anthracite). Second band from the bottom has cut-out 1/4" logo backer plate, painted P.3 (Black), with 1/4" raised logo, P.2 (Lionshead Anthracite), 2-sides. Top of post has domed cap.
2-Layer brand logo of 1/2" plate stock, 2-sides.
Short TermParking Only
Drop-Off
Welcome Center
6'-
0
"
12
'
-
6
"
7'-
0
"
LI
O
N
S
H
E
A
D
W
E
L
C
O
M
E
C
E
N
T
E
R
BLDG. SIGNAGE & GRAPHICSConceptual Design4 October, 2012
Lionshead Welcome CenterTown of Vail
PROJECT
Greg Hall, Town of Vail
CLIENT CONTACT
HB, JM, DT
TEAM
PedestrianDirectional-
Wall Mount
3.2.1
1112 Pearl Street Boulder, CO 80302TEL 303.447.8202 FAX 303.440.7069www.commarts-boulder.comwww.stantec.com
These drawings express visual design intent only. Final engineering, materials and fabrication shall remain the responsibility of the fabricator.
1 Elevation Detail
SCALE: 3/8"= 1'-0"
Level 1 Core Entry
Level 1 Core Entry
Sign Tpe 1.4.1s
Level 2Core Entry
Level 2 Core Entry
Level 2 Pedestrian EntrySouth Wall Level 2 Pedestrian EntryNorth Wall
Level 2 Pedestrian EntrySouth Wall
Level 2 Pedestrian EntryNorth Wall
Vail Recreation DistrictImagination StationVRD Community Programming
Lionshead VillageWelcome Center
The Grand ViewTransit Center
Lionshead VillageWelcome Center
Lionshead VillageWelcome Center
Lionshead VillageWelcome Center
1/4" Plate aluminum sign panel pinned 1 1/2" off (stone) wall surface. Panel painted P.1 (Dk. Lionshead Red).
1/4" x 11/2" Attachment straps at top and bottom. Straps painted P.3 (Black). 1/2" Dia. vandal resistant head fasteners, painted to match field.
Messages are masked and enamel painted P.4 (White)
Note- It is anticipated to use the ECO Transit logo where applicable
LI
O
N
S
H
E
A
D
W
E
L
C
O
M
E
C
E
N
T
E
R
BLDG. SIGNAGE & GRAPHICSDesign Intent4 October, 2012
Lionshead Welcome CenterTown of Vail
PROJECT
Greg Hall, Town of Vail
CLIENT CONTACT
HB, JM, DT
TEAM
Pedestrian Direc-tionalExisting Pole Mount Directional Panels
3.2.4
1112 Pearl Street Boulder, CO 80302TEL 303.447.8202 FAX 303.440.7069www.commarts-boulder.comwww.stantec.com
These drawings express visual design intent only. Final engineering, materials and fabrication shall remain the responsibility of the fabricator.
2 Elevation
SCALE: 1/2"= 1'-0"
1 Axonometric
SCALE: NTS
3 Photo Composite
SCALE: NTS
Note: this sign type is of the same construction as Sign Type 1.3.4: Existing Pole Mount Facility I.D.
As a directional sign, this type includes an arrow icon.
2-Sided cabinet construction blade mount icon signs fastened to an existing (light) pole.
3" Thick fabricated icon shapes are supported by 10" high bracket arms, same thickness that fasten to compression cuffs that wrap existing posts (post sizes will vary). Entire assembly painted P.3 (Black).
Both faces of icon shapes have inset 1/4" plate stock panels, secured with countersunk vandal resistant mechanical fasteners, painted P.1 (Dk. Lionshead Red).
Faces of inset panels have masked and enamel painted graphics, P.4 (White).
Compression cuffs
Bracket Arm
Icon Frame
Inset icon faces
Painted Graphics
14
'
-
8
"
To
t
a
l
14
'
-
0
"
Po
l
e
s
8'
-
0
"
Min
1'-
2
"
Ic
o
n
F
r
a
m
e
1'-
3
1
/
2
"
Ar
r
o
w
F
r
a
m
e
10
"
Cu
f
f