Loading...
HomeMy WebLinkAboutDRB120461 Approved PlansLIONSHEAD WELCOME CENTER LIONSHEAD WELCOME CENTER BUILDING SIGNAGE & GRAPHICS Design Intent 4 October, 2012 prepared for the 1112 Pearl Street Boulder, CO 80302 TEL 303.447.8202 FAX 303.440.7069 www.commarts-boulder.com www.stantec.com 4Oc LI O N S H E A D W E L C O M E C E N T E R BLDG. SIGNAGE & GRAPHICSDesign Intent4 October, 2012 Lionshead Welcome CenterTown of Vail PROJECT Greg Hall, Town of Vail CLIENT CONTACT HB, JM, DT TEAM Table of Contents 0.1 1112 Pearl Street Boulder, CO 80302TEL 303.447.8202 FAX 303.440.7069www.commarts-boulder.comwww.stantec.com These drawings express visual design intent only. Final engineering, materials and fabrication shall remain the responsibility of the fabricator. table of contents Sign Inventory Performance Specifications Materials & Finishes Fonts & Symbols Location Plans Sign Drawings Identification Informational Directional 0.1 0.2 0.3 0.4 0.LP 1.1 2.1 3.1 LI O N S H E A D W E L C O M E C E N T E R BLDG. SIGNAGE & GRAPHICSDesign Intent4 October, 2012 Lionshead Welcome CenterTown of Vail PROJECT Greg Hall, Town of Vail CLIENT CONTACT HB, JM, DT TEAM Sign Inventory 0.1 1112 Pearl Street Boulder, CO 80302TEL 303.447.8202 FAX 303.440.7069www.commarts-boulder.comwww.stantec.com These drawings express visual design intent only. Final engineering, materials and fabrication shall remain the responsibility of the fabricator. These drawings express visual design intent only. Final engineering, materials and fabrication shall remain the responsibility of the fabricator. $ 25,000 $ 25,000 $ 15,000 $ 2,000 $ 6,000 $ 300 $ 100 $ 500 $ 3,000 $ 100 $ 100 $ 10 $ 1,000 $ 100 $ 1,000 $ 4,000 $ 25,000 $ 25,000 $ 15,000 $ 2,000 $ 18,000 $ 600 $ 200 $ 1,000 $ 9,000 $ 5,600 $ 5,600 $ 4,250 $ 10,000 $ 1,100 $ 3,000 $ 4,000 Quantity Description Sign TypePage No.Unit Cost Ext'd Cost - 1 2 1 1 1 1 1 9 1 5 (10 panels) 1 (2 panels) 1 (1 panel) 1 1 3 4 8 16 - 1 (2 units) - 2 4 2 6 5 9 2 1 IDENTIFICATION Primary Project I.D. Secondary Welcome Center I.D. Transit Center I.D. Entry I.D. Primary Project Entry I.D. VRD Entry I.D. The Grand View Entry I.D. Drop-Off, Short Term Parking Garage Entry (West Elevation) Freestanding Short Term Parking Garage Entry Facility I.D. Flat Mount Icon Panels Small Flat Mount Panels Blade Mount Icon Panels Single Pole Mount Icon Panels Existing Pole Mount Icon Panels Suspended Icon Stained Icon Level I.D. Small Level I.D. Public Room I.D. (with icon) Smaller Public Room I.D. (no icon) Designated Space I.D. Clearance I.D. Temp. I.D. Virtual Concierge I.D. INFORMATIONAL Project Directories Elevator Lobby Directory Elevator Cab Directory Entry Door Information Entry Door 50th Anniversary Logos Life Safety Temporary/Moveable Informational Misc. Informational 1.1.1 1.1.2 1.1.3 1.2.1 1.2.2 1.2.3 1.2.4 1.2.5 1.3.1 1.3.1s 1.3.2 1.3.3 1.3.4 1.3.5 1.3.6 1.4 1.4s 1.5 1.5s 1.6 1.7 1.8 1.9 2.1.1 2.1.2 2.2 2.2c 2.3 2.4 2.5 Project signature located at top of tower, highly visible from many directions and from a great distance. Iconographic landmark. Project signature (not an entry) on North side of building at parking level 1 skier drop-off area. Externally illuminated corten sign panel and edge lit icon sign assemblies. North and South elevations of Transit Center on Frontage Rd. Externally illuminated corten sign panel sign assembly. Primary South face street level entry into Welcome Center facility. Externally illuminated corten sign panel and edge lit icon sign assemblies. North 2nd level entry into VRD facilities. Externally illuminated corten sign panel sign assembly. North 3rd level entry into Vail Community room (name TBD). Externally illuminated corten sign panel sign assembly. West street level entry into short term/skier drop-off area of parking structure. (Existing) Externally illuminated corten sign panel and edge lit icon sign assemblies. West street level entry into short term/skier drop-off area of parking structure. Externally illuminated corten sign panel and edge lit icon sign assemblies. Metal sign face on fabricated frame pinned off (stone, wood,...) surfaces. Painted graphics. Non illuminated. Smaller version of above. Perpendicular mounted metal sign faces on fabricated frames attached to base plate. Painted graphics. Non illuminated. Freestanding clustered pole assembly with blade mount sign panels. Blade mount sign panels attached to an existing streetlight or pole. Fabricated Information icon cabinet with edge illuminated frosted acrylic behind corten face plate. Assembly suspended from base plate. Information icon presented at a very large scale and at very low contrast. Transparent stain on beetle-kill wood rear wall of info desk area. Metal sign face on fabricated frame pinned off (stone, wood,...) surfaces. Painted graphics. Non illuminated. Smaller version of above. ADA compliant tactile identification signs for all rooms & spaces: restrooms, lockers, utility rooms. Current units should be replaced by project specific (color, typeface). Smaller version of above. Not a public use room, no icon included. Pole mount (typ.) sign panels identifying reserved parking spaces or curb areas. Project specific colors/typefaces replace any existing off-the-shelf units. Suspended thin wall aluminum tubes identifying the clearance limits of the parking structure. Inexpensive machine-cut reflective & matte vinyl graphics. Installed August, 2012 Metal sign face on fabricated frame pinned off wall surfaces. Painted graphics. Non illuminated. Destination and facility listings, including international symbols, located at all elevator lobbies. May include Level I.D. sign violator panels. Destination and facility listings, including international symbols, located in all elevator cabs. Facility services/offerings on glass entry doors rendered in 2nd surface white matte machine-cut vinyl. Temporary decals celebrating the town’s 50th anniversary. Full color digital prints on white vinyl. Code required life safety signs: Maximum Occupancy, Stairwell Informational, These Doors to Remain Open...., In Case of Fire.... Vehicular and Pedestrian scaled temporary/moveable sign assemblies, deployed as required. As required. sign inventory LI O N S H E A D W E L C O M E C E N T E R BLDG. SIGNAGE & GRAPHICSDesign Intent4 October, 2012 Lionshead Welcome CenterTown of Vail PROJECT Greg Hall, Town of Vail CLIENT CONTACT HB, JM, DT TEAM Sign Inventory cont. 0.1.2 1112 Pearl Street Boulder, CO 80302TEL 303.447.8202 FAX 303.440.7069www.commarts-boulder.comwww.stantec.com These drawings express visual design intent only. Final engineering, materials and fabrication shall remain the responsibility of the fabricator. These drawings express visual design intent only. Final engineering, materials and fabrication shall remain the responsibility of the fabricator. $ 25,000 $ 25,000 $ 15,000 $ 2,000 $ 6,000 $ 300 $ 100 $ 500 $ 3,000 $ 100 $ 100 $ 10 $ 1,000 $ 100 $ 1,000 $ 4,000 $ 25,000 $ 25,000 $ 15,000 $ 2,000 $ 18,000 $ 600 $ 200 $ 1,000 $ 9,000 $ 5,600 $ 5,600 $ 4,250 $ 10,000 $ 1,100 $ 3,000 $ 4,000 Quantity Description Sign TypePage No.Unit Cost Ext'd Cost 1 - 4 - - 1 (3 panels) - 2 DIRECTIONAL Vehicular Directional Vehicular Banner Pole Pedestrian Directional Flat Mount Directional Blade Mount Directional Pole Cluster Mount Directional Existing Pole Mount Directional Single Tapering Pole Mount Misc. Directional THEMATIC Map Display Holders 3.1.1 3.1.2 3.2.1 3.2.2 3.2.3 3.2.4 3.2.5 3.3 4.5 Directional sign panels, scaled and positioned for vehicular use. Signs typically rely upon reflective vinyls for visibility. Large scale vertical pole mounted banners. Adds color & graphics, aids in direction Metal sign face on fabricated frame pinned off (stone, wood,...) surfaces. Painted graphics. Non illuminated. Perpendicular mounted metal sign faces on fabricated frames attached to base plate. Same sign assembly as above mounted to a freestanding clustered pole assembly. Non-illuminated. Blade mount sign panels attached to an existing streetlight or pole. Same sign assembly as above mounted to a single, tapering, banded post assembly. Non-illuminated. 2-Layer acrylic frames suspended bu floor to ceiling cable system. sign inventory LI O N S H E A D W E L C O M E C E N T E R BLDG. SIGNAGE & GRAPHICSDesign Intent4 October, 2012 Lionshead Welcome CenterTown of Vail PROJECT Greg Hall, Town of Vail CLIENT CONTACT HB, JM, DT TEAM ContractorPerformance and Material Requirements 0.2 1112 Pearl Street Boulder, CO 80302TEL 303.447.8202 FAX 303.440.7069www.commarts-boulder.comwww.stantec.com These drawings express visual design intent only. Final engineering, materials and fabrication shall remain the responsibility of the fabricator. required to complete fabrication and installation of the specified work. Full compliance with these Contractor Performance and Material Requirements will be required.The Contractor is encouraged to make recommendations for specific changes if they will improve the quality or cost-effectiveness of fabrication while preserving Stantec/CommArts’ visual design intent. However, any such recommendations must be approved in writing by the Owner and Stantec/CommArts at the time of bid. Should the Contractor be contracted based on a proposal that assumes substitutions that have not been properly approved, the Contractor shall be responsible for providing all elements as originally indicated at their own expense. B. Shop Drawings The Contractor shall submit shop drawings of all fabricated items to the Owner and Stanec/CommArts. This submission shall consist of three hard copy sets of detailed drawings that indicate all materials, finishes, construction details, lighting requirements, installation details and artwork, including locations of all material seams. Drawings shall include elevations, plans, sections and notes as required to clearly convey fabrication intent. Stantec/CommArts will review samples for aesthetic appearance and compatibility with adjacent conditions. Compliance with other requirements is the exclusive responsibility of the Contractor. Upon review, the Contractor shall make all requested revisions and resubmit as required. A complete set of approved shop drawings (noted “No Exceptions Taken” or “Exceptions as Noted”) must be received from both the Owner and Stantec/CommArts before production may begin. C. Submittals The Contractor is responsible for providing submittals to the Owner and Stantec/CommArts as required per “Quantities & Submittals” section of this document. Stantec/CommArts will review samples for aesthetic appearance and compatibility with adjacent conditions. Compliance with other requirements is the exclusive responsibility of the Contractor. All materials, finishes and content are subject to revision until final submittals have been approved. A complete set of approved submittals must be received from both the Owner and Stantec/CommArts before fabrication may begin. Required submittals must be issued in an adequate time frame to allow review, adjustments and approval without delaying the project schedule. III. FABRICATION & INSTALLATION REQUIREMENTS A. Permitting & Regulation Compliance The Contractor is responsible for securing and paying for all permits, insurances, inspections and tests required by governmental agencies. The Contractor is responsible for submitting all necessary permit information to the Building Department review and approval for all applicable permits as rquired per the Town of Vail and 2011 IBC. The Fabricator is also responsible for verifying and ensuring compliance This document has been assembled by Stantec/CommArts with the expectation that the Contractor will meet the following quality and performance requirements. The acceptance of these drawings by the Fabricator constitutes agreement to comply with the following conditions. The Owner will hold the Fabricator to these requirements as part of their contract obligations. I. GENERAL A. Proprietary Information Non-Disclosure Agreement All ideas, designs, arrangements and plans indicated orpresented by these drawings are the property of the Owner and were created for use in connection with the specified project. The information in this document is confidential and shall not be disseminated to anyone other than Stantec/CommArts, the Owner or the Contractor’s personnel necessary to execute the contract, without the written permission of Stantec/CommArts and the Owner. In addition, the Contractor must request and receive written approvals from both the Owner and Stantec/CommArts to use images of any completed element. The Contractor is responsible for ensuring that credit indicating Stantec/CommArts as the Designer will accompany all images and articles related to the project. The Owner may have additional requirements or restrictions for which the Contractor is also responsible. B. Design Intent Drawings The “design intent” drawings contained in this document are for the sole purpose of expressing visual design intent and are not intended for construction purposes. All aspects of fabrication, installation and any resulting working drawings, shop drawings, submittals, building permits meeting 2011 IBC with necessary professionally engineered drawings and contract documents are the responsibility of the Contractor. Within the design intent drawings: • All written dimensions take precedence over dimensions otherwise implied by drawing scale, figures, etc. • Large scale details take precedence over the smaller scale drawings. • Specific recommendations for materials, colors and content take precedence over representations shown in drawings. II. PRE-FABRICATION REQUIREMENTS A. Proposal Copies of all pricing and bid information shall be sent to the Owner and Stantec/CommArts. The Contractor shall base their proposal on the performance of all items or service including labor, materials, equipment and resources. with all ADA, OSHA, environmental regulations and all other applicable governing code requirements. All required resolutions or revisions to construction details must be approved by the Owner and Stantec/CommArts prior to production. B. Structural Requirements The Contractor shall follow Stantec/CommArts’ drawings for exterior visual appearance but designs of internal structure, engineered connections, mounting assemblies and foundations are by the Contractor. Structural design shall utilize self-supportive framing and prevent irregularities in exposed surfaces. Deliverables: • The Contractor shall reference Architecural Drawings for full mounting location conditions and shall coordinate all necessary waterproofing, support and/or blocking requirements and approximate weights for each element as required no later than twenty-one days after final shop drawing approval. Drawings will be provided in electronic format (PDF) by Owner. • The Fabricator shall provide the Owner and/or the GC with calculations for all structural members and foundations sealed by certified engineers registered in the state of installation, prior to fabrication. C. Electrical Requirements Design of all electrical components is by the Contractor. All transformers and electrical hardware shall be concealed (i.e. non-audible and non-visible to pedestrian and vehicular traffic). The Contractor shall ensure all electrical components are easily accessible for maintenance and servicing. All necessary point-of-connection coordination is the responsibility of the Contractor. All connections must be in compliance with the requirements of the NEC and all other applicable governing code requirements. All necessary electrical components and assemblies are to be UL listed or approved by a nationally recognized testing lab. All electrical components shall be warranted against failure for at least two years. Within the warranty period, defective electrical components are to be replaced by the Contractor within forty-eight hours of notice by the Owner. Should the Contractor fail to replace defective components within the specified time, these items may be replaced by others at the Contractor’s expense. Deliverables: • The Contractor shall provide the Owner with a list of electrical requirements for each element no later than twenty-one days after final shop drawing approval. D. Lighting The Contractor shall follow Stantec/CommArts’ drawings for visual appearance but design of internal structure, fixtures and mounting assemblies is by the contractor per formance & material requirements LI O N S H E A D W E L C O M E C E N T E R BLDG. SIGNAGE & GRAPHICSDesign Intent4 October, 2012 Lionshead Welcome CenterTown of Vail PROJECT Greg Hall, Town of Vail CLIENT CONTACT HB, JM, DT TEAM ContractorPerformance and Material Requirements 0.2.2 1112 Pearl Street Boulder, CO 80302TEL 303.447.8202 FAX 303.440.7069www.commarts-boulder.comwww.stantec.com These drawings express visual design intent only. Final engineering, materials and fabrication shall remain the responsibility of the fabricator. H. Safety & Responsibility The Contractor shall be responsible for providing barricade or protective coverings as necessary to safeguard the public and property during the performance and duration of their work. The Contractor shall be fully responsible for any injuries to the public or damage to the buildings, site and adjacent objects during installation. The Contractor shall be responsible for cleaning up all work areas upon the completion of work on a daily basis. All installed items shall be left in a clean and as-new condition. The Contractor shall be fully responsible for the security and quality of all equipment, materials and installed components until they have been reviewed and accepted by the Owner. III. MATERIAL STANDARDS All materials, hardware and finishes used to fabricate any and all components shall be new (i.e. not previously used or operated in any other application) and from the most recent manufacturer’s production supply. A. Paints & Finishes All paints and finishes shall match exactly the color, finish and texture noted. Unless otherwise noted, all pretreats, primers, coatings and finishes shall be applied in strict accordance with the paint manufacturer’s specifications to provide the highest level of ultraviolet light resistance, weatherability and overall longevity for both the materials indicated and the environmental conditions of the final install locations. Paints & finishes shall be warranted against color fading, UV damage cracking, peeling, blistering and other defects in materials or workmanship for a minimum of five years from date of Owners acceptance. B. Metals Metals shall be the best commercial quality for the purposes specified and free from defects impairing strength, durability or appearance. Unless otherwise noted, all visible seams are to be continuously welded, filled and ground smooth. All sheet metal shall have brake formed edges with radii not greater than sheet thickness. All metals must be treated to prevent corrosion and staining of other finishes. C. Fasteners Unless otherwise noted, all exposed fasteners shall be tamper-proof, resistant to oxidation and other corrosion and painted to match adjacent surfaces. Concealed fasteners must be resistant to oxidation and other corrosion to prevent staining of other finishes. D. Vinyl All vinyl sheeting shall match exactly the color, finish and durability of the manufacturer’s product as noted. Unless otherwise noted, all vinyl sheeting shall be installed in strict accordance with the manufacturer’s specifications to provide the highest level of ultraviolet light resistance, weatherability and overall longevity for both the materials indicated and the environmental conditions of the final install locations. Vinyl sheeting shall be warranted against color fading, UV damage, delamination or peeling for a period of five years from date of Owner’s acceptance. E. Digital Prints All high resolution digital output must provide the highest level of ultraviolet light resistance, weatherability and overall longevity for both the materials indicated and the environmental conditions of the final install locations. Unless otherwise noted, digital prints shall have a minimum resolution of 200 dpi. Printed product shall be warranted against color fading, UV damage, delamination or peeling for a minimum of five years from date of the Owner’s acceptance. IV. PROJECT COMPLETION A. Paints & Finishes The Contractor shall notify both Stantec/CommArts and the Owner in writing when all work is completed. Upon notice, Stantec/CommArts will review all work according to their contract with the Owner and prepare a punch list outlining incomplete or unsatisfactory items. The repair or replacement of work outlined on the punch list shall be coordinated between the Contractor and the Owner. B. Final Deliverables Upon the Owner’s acceptance of the work, the Contractor shall provide the Owner with three copies of a complete service and maintenance manual for all products and finishes installed under their contract. This manual shall include, but is not limited to, product specifications such as manufacturer information, contact names and addresses, warranty information, technical data and routine maintenance recommendations for light fixtures, electrical components, paint, finishes and all other applicable items. C. Warranties All warranty periods shall begin on the date of the Owner’s acceptance of the work. All warranties shall include the materials and labor required to replace defective components. Unless otherwise stated above, all installed components shall be warranted against manufacturer defects for a minimum of two years and all installed elements shall be warranted against defects in installation or workmanship for a minimum of three years. Contractor. The Contractor shall ensure all lighting components are easily accessible for maintenance and servicing. Unless otherwise noted, the interior of all illuminated enclosures shall be painted matte white to increase reflectivity. All lighting components shall be constructed per recognized national standards and/or specific manufacturer’s recommendations. All neon components shall be warranted against failure for at least three years and all other lighting components shall be warranted for at least two years. Within the warranty periods, failed lighting components are to be replaced by the Contractor within forty-eight hours of notice by the Owner. Should the Contractor fail to replace defective components within the specified time, these items may be replaced by others at the Contractor’s expense. E. Labeling Visible labels, manufacturer’s or otherwise, code permitting, shall not appear on any completed element. The placement of any required labels must be approved by Stantec/CommArts prior to application and installation. F. Artwork & Fonts Stantec/CommArts will provide the Contractor with layout guidelines and electronic artwork as required, however all final copy layouts are the responsibility of the Fabricator. The Contractor shall legally acquire at their own expense all project fonts from the specified distributors. Stantec/CommArts will not provide copies of licensed fonts. When stock imagery is used, Stantec/CommArts will provide the Fabricator with the image specifications and a low resolution electronic file for placement. The purchasing of high resolution final images, licensing and all applicable fees are the responsibility of the Contractor. All acquired images shall be registered in the Owner’s name. G. On-Site Coordination All locations shown in the enclosed location plans are approximate. The Contractor is responsible for referencing applicable Architectural Drawings, field verification and coordination of all final locations. The Contractor shall notify the Owner and Stantec/CommArts of any discrepancies between Stantec/CommArts’ drawings, location plans or message schedule and field conditions prior to installation. All required resolutions or revisions to construction details must be approved by the Owner and Stantec/CommArts prior to production. The Contractor’s installation responsibilities include the provision of any required footings, anchor bolts or fastenings. All point-of-connection coordination is the responsibility of the Contractor. Deliverables: • The Contractor shall provide the Owner with templates and patterns as required no later than twenty-one days after final shop drawing approval. LI O N S H E A D W E L C O M E C E N T E R BLDG. SIGNAGE & GRAPHICSDesign Intent4 October, 2012 Lionshead Welcome CenterTown of Vail PROJECT Greg Hall, Town of Vail CLIENT CONTACT HB, JM, DT TEAM Materials & Finishes 0.3 1112 Pearl Street Boulder, CO 80302TEL 303.447.8202 FAX 303.440.7069www.commarts-boulder.comwww.stantec.com These drawings express visual design intent only. Final engineering, materials and fabrication shall remain the responsibility of the fabricator. P.3 Black15 MP32156 Black Magic P.1 Dk. Lionshead Red114 MP15793 Town & Country Red P.2 Lionshead Anthracite22 MP12718 Unicor Brown P.4 White13 MP32351 White Spirit Paints V.1 Reflective White 3M Engineer Grade Reflective White V.2 Matte White V.3 3-M Matte Black Vinyl M.1 Faux Corten FinishSample to be provided to Fabricator for matching M.2 Frosted Acrylic M.3 Non-glare Acrylic Materials/Finishes LI O N S H E A D W E L C O M E C E N T E R BLDG. SIGNAGE & GRAPHICSDesign Intent4 October, 2012 Lionshead Welcome CenterTown of Vail PROJECT Greg Hall, Town of Vail CLIENT CONTACT HB, JM, DT TEAM Fonts, Artwork & Symbols 0.4 1112 Pearl Street Boulder, CO 80302TEL 303.447.8202 FAX 303.440.7069www.commarts-boulder.comwww.stantec.com These drawings express visual design intent only. Final engineering, materials and fabrication shall remain the responsibility of the fabricator. ABCDEFGHIJKLMNOPQRSTUVWXY & Z abcdefghijklmnopqrstuvwxy & z 1234567890 ABCDEFGHIJKLMNOPQRSTUVWXY & Z abcdefghijklmnopqrstuvwxy & z 1234567890 VAIL RECREATION DISTRICT Helvetica Neue LT Std. 67 Med. Condensed Helvetica Neue LT Std. 77 Bold Condensed Customized Icon for Bldg. I.D. rendered in LionsHead Welcome Center material: corten Bldg. Tenant I.D.’s Client logos (currently not being used) Vail Icons, rendered in LionsHead Welcome Center Dk. Red LI O N S H E A D W E L C O M E C E N T E R BLDG. SIGNAGE & GRAPHICSDesign Intent4 October, 2012 Lionshead Welcome CenterTown of Vail PROJECT Greg Hall, Town of Vail CLIENT CONTACT HB, JM, DT TEAM Location Plan Site Plan 0.LP.Site 1112 Pearl Street Boulder, CO 80302TEL 303.447.8202 FAX 303.440.7069www.commarts-boulder.comwww.stantec.com These drawings express visual design intent only. Final engineering, materials and fabrication shall remain the responsibility of the fabricator. Loc. S.1 S.2 S.3S.4 Type 1.3.2 1.1.3 1.3.31.1.3 Message (Icons: Restrooms, Bus Transit) (New pole) LIONSHEAD VILLAGE Transit Center (Icons: Restrooms, Bus Transit) (Blade mount)LIONSHEAD VILLAGE Transit Center Loc. S.5 S.6 S.7 Type 1.9 3.1.1 1.2.5 Message (Icon) Interactive Virtual Concierge Short Term Parking (Icons) Drop-Off, Welcome Center Lionshead Village Welcome Center Drop-Off & Short Term Parking Only (Arrow) 1.1.3S.4 1.3.3S.1 1.3.2S.3 1.1.3S.2 1.2.5S.7 3.1.1S.6 1.9S.5 LI O N S H E A D W E L C O M E C E N T E R BLDG. SIGNAGE & GRAPHICSDesign Intent4 October, 2012 Lionshead Welcome CenterTown of Vail PROJECT Greg Hall, Town of Vail CLIENT CONTACT HB, JM, DT TEAM Location Plan Level 1 0.LP1 1112 Pearl Street Boulder, CO 80302TEL 303.447.8202 FAX 303.440.7069www.commarts-boulder.comwww.stantec.com These drawings express visual design intent only. Final engineering, materials and fabrication shall remain the responsibility of the fabricator. 1.3.11.11 1.3.1 1.12 1.71.1 1.2.41.2 1.41.13 1.41.14 1.3.11.21 1.3.11.22 1.3.11.23 1.3.11.24 1.2.11.33 1.3.41.32 2.2 1.34 2.2c 1.52 2.2c1.47 1.91.48 2.31.35 2.21.43 2.2c1.54 1.5s1.381.3.21.37 1.3.51.28 1.3.11.49 4.51.50 4.51.51 2.51.53 1.3.11.45 1.1.21.36 1.3.21.27 2.31.16 2.1.11.15 2.1.11.192.1.21.17 2.1.21.18 1.5s1.3 1.5s1.4 1.5s1.8 1.5s1.6 1.5s1.7 2.31.20 1.51.40 1.51.42 2.21.25 2.21.55 2.2c1.46 1.3.21.44 1.3.61.29 3.2.41.10 3.2.31.9 1.4s1.31 3.2.11.30 1.5s1.5 1.51.39 1.51.41 AB Loc. 1.1 1.2 1.3 1.4 1.5 1.61.7 1.8 1.9 1.101.11 1.12 1.13 1.141.15 1.161.17 1.18 1.19 1.20 1.21 1.221.23 1.24 1.25 1.261.27 1.28 1.29 1.30 1.31 1.321.33 1.34 1.35 1.36 1.37 1.38 1.39 1.40 1.411.42 1.43 1.44 1.55 Type 1.7 1.2.4 1.5s 1.5s1.5s 1.5s 1.5s 1.5s3.2.3 3.2.4 1.3.1 1.3.1 1.41.4 2.1.1 2.32.1.2 2.1.2 2.1.1 2.31.3.1 1.3.1 1.3.1 1.3.12.2 2.2 1.3.2 1.3.5 1.3.6 3.2.1 1.4s1.3.4 1.2.1 2.2 2.3 1.1.2 1.3.2 1.5s 1.5 1.5 1.5 1.5 2.2 1.3.2 2.2 Message Clearance 7'-0" (2 units)Lionshead Village Welcome Center Drop-Off (icon) Short Term Parking (icon) TBD (Braille) 129 (Braille) 123 (Braille) WATER ENTRY (Braille) ELEVATOR MECHANICAL (Braille) IT (Braille)(Arrow, Eco Transit, Restrooms) (3) Panels: (Arrow, Info, Restrooms) (Icon: Parking) (Icon: Drop-Off) p1, Do You Remember... p1, Do You Remember... 3 The Grand View (Icons: Restrooms, Eco Transit) 2 Vail Recreation District Imagination Station VRD Community Programming 1 Drop-Off Short Term Parking (Icon: Drop-Off) Lobby/Street Lionshead Village (Icons: Info, Restrooms, Lockers, ATM) In Case of Fire...(same as 1.15 above) (same as 1.15 above) 3 The Grand View (Icons: Restrooms, Eco Transit)2 Vail Recreation District Imagination Station VRD Community Programming 1 Drop-Off Short Term Parking (Icon: Drop-Off) Lobby/Street Lionshead Village (Icons: Info, Restrooms, Lockers, ATM)In Case of Fire... (Icon: Handicap Access) (Icon: Parking) (Icon: Elevator) (Icon: ATM) Elevators & ADA Access to Parking, Address LHWC, Restrooms, Public Lockers (1) Panel: (Icon: Elevator) (Icon: Information)(Icon: Information) a Lionshead Village (Icons: Information, Restrooms, Lockers, ATM) p1, Do You Remember.... (1) Panel: (Icon: Information) Lionshead Village Welcome Center (Icon: Information) LHWCMaximum Occupancy 395 Lionshead Village Welcome Center (Icon: Information) (2) Panels: A (Icons: Restrooms, Lockers) B (Icons: Information, Elevator) ELECTRIC ROOM (Braille) (Women) WOMEN (Braille) (Family) FAMILY (Braille) (Men) MEN (Braille)(Lockers) Public Lockers Restrooms & Public Lockers (Icons: Restrooms, Lockers) (blade mount) LHWC, Restrooms & Lockers Grayed back signs are not included in this contract. Loc. 1.45 1.46 1.47 1.48 1.49 1.50 1.51 1.521.53 1.54 Type 1.3.1 2.2c 2.2c 1.9 1.3.1 4.5 4.5 2.2c2.5 2.2c Message (Icon- Elevator) (Vail’s 50th logo) (Vail’s 50th logo) (Icon) Interactive Virtual Concierge Round panel (Arrow), square panel (Restrooms) (Map holder) (Map holder)(Vail’s 50th logo) Short Term Locker Use Only.... (Vail’s 50th logo) Deleted Deleted Deleted Deleted Added Added Changed Changed from 1.4 to 1.3.1 LI O N S H E A D W E L C O M E C E N T E R BLDG. SIGNAGE & GRAPHICSDesign Intent4 October, 2012 Lionshead Welcome CenterTown of Vail PROJECT Greg Hall, Town of Vail CLIENT CONTACT HB, JM, DT TEAM Location Plan Level 2 0.LP2 1112 Pearl Street Boulder, CO 80302TEL 303.447.8202 FAX 303.440.7069www.commarts-boulder.comwww.stantec.com These drawings express visual design intent only. Final engineering, materials and fabrication shall remain the responsibility of the fabricator. 3.2.12.1 1.4s2.2 1.4s 2.4 1.4s2.6 3.2.1 2.3 3.2.12.5 1.2.22.12 2.32.13 2.22.15 1.5s2.17 1.5s2.19 1.5s2.16 1.5s2.18 1.52.20 1.5s2.22 1.5s2.23 2.32.25 1.52.21 2.32.10 2.1.12.9 1.42.8 1.42.7 2.42.14 1.5s2.24 Loc. 2.1 2.2 2.3 2.4 2.5 2.6 2.7 2.8 2.9 2.102.11 2.12 2.13 2.14 2.15 2.16 2.172.18 2.19 2.20 2.212.22 2.23 2.24 2.25 Type 3.2.1 1.4s 3.2.1 1.4s 3.2.1 1.4s 1.4 1.4 2.1.1 2.3 1.5s 1.2.2 2.3 2.42.2 1.5s 1.5s 1.5s 1.5s1.5 1.5 1.5s 1.5s1.5s 2.3 Message a The Grand View (Icons: Eco Transit, Restrooms) d Vail Recreation District Imagination Station VRD Community Programming p2 f Vail Recreation District Imagination Station VRD Community Programming h Lionshead Village (Icons: Information, ATM, Restrooms, Lockers) p2, Do You Rememeber.... a (Icon: Elevator) d Lionshead Village (Icons: Information, ATM, Restrooms, Lockers) p2, Do You Remember...p2, Do You Remember... p2, Do You Remember... p3 The Grand View (Icons: Restrooms, Eco Transit) p2 Vail Recreation District Imagination Station VRD Community Programming p1 Drop-Off Short Term Parking (Icon: Drop-Off) Lobby/Street Lionshead Village (Icons: Info, Restrooms, Lockers, ATM) In Case of Fire... MECHANICAL (Braille) Vail Recreation District Imagination Station VRD Community ProgrammingMaximum Occupancy 47 (Changeable Message Area) (TBD, Hr.s of Operation) 204 (Braille)203 Mad Scientist Lab 205 (Braille) 206 (Braille) (Restroom) UNISEX ADULT (Braille) (Restroom) UNISEX CHILDREN (Braille)210 (Braille) MECHANICAL (Braille) STAIR (Braille) Maximum Occupancy 41 1.5s2.11 Grayed back signs are not included in this contract. Deleted Deleted LI O N S H E A D W E L C O M E C E N T E R BLDG. SIGNAGE & GRAPHICSDesign Intent4 October, 2012 Lionshead Welcome CenterTown of Vail PROJECT Greg Hall, Town of Vail CLIENT CONTACT HB, JM, DT TEAM Location Plan Level 3 0.LP3 1112 Pearl Street Boulder, CO 80302TEL 303.447.8202 FAX 303.440.7069www.commarts-boulder.comwww.stantec.com These drawings express visual design intent only. Final engineering, materials and fabrication shall remain the responsibility of the fabricator. Loc. 3.1 3.23.3 3.4 3.53.6 3.7 3.8 3.9 3.103.11 3.12 3.13 3.143.15 Type 3.2.3 1.3.22.3 2.1.1 1.41.4 1.2.3 1.3.1s 2.4 1.5 1.5 2.2 2.3 2.31.5s Message A k (Icons: Information, ATM) B d (Icon: Eco Transit) (Icons: Elevator, Restrooms, Information) In Case of Fire... p3 The Grand View (Icons: Restrooms, Eco Transit) p2 Vail Recreation District Imagination Station VRD Community Programming p1 Drop-Off Short Term Parking (Icon: Drop-Off) Lobby/Street Lionshead Village (Icons: Info, Restrooms, Lockers, ATM) p3, Do You Remember...p3, Do You Remember... The Grand View (Icon: Restrooms) (Changeable Message Area) (Women) WOMEN (Braille) (Men) MEN (Braille) The Grand View (Phone No.? web link?) Maximum Occupancy 270 Maximum Occupancy 36STAIR (Braille) A B3.2.3 3.1 1.3.23.2 1.2.33.7 2.43.9 2.23.12 1.3.1s3.8 1.53.10 1.53.11 2.33.13 1.5s3.152.33.142.33.3 2.1.13.4 1.43.5 1.43.6 Grayed back signs are not included in this contract. Deleted Deleted Deleted Deleted LI O N S H E A D W E L C O M E C E N T E R BLDG. SIGNAGE & GRAPHICSDesign Intent4 October, 2012 Lionshead Welcome CenterTown of Vail PROJECT Greg Hall, Town of Vail CLIENT CONTACT HB, JM, DT TEAM Location Photo 0.LP4 1112 Pearl Street Boulder, CO 80302TEL 303.447.8202 FAX 303.440.7069www.commarts-boulder.comwww.stantec.com These drawings express visual design intent only. Final engineering, materials and fabrication shall remain the responsibility of the fabricator. Flat mount Pedestrian Directionaland Small Level I.D.Sign Types 3.2.1 & 1.4s Existing post mount Pedestrian DirectionalSign Type 3.2.4 Existing post mount Facility I.D.Sign Type 1.3.4 Entry I.D.South Entry 1Facility I.D. Sign Type 1.3.1 Level I.D.South Entry 1All levels, East sideSign Type 1.4 Entry I.D.South Entry 2Facility I.D.Sign Type 1.3.1 Project Entry I.D.South Entry 3Facility I.D.Sign Type 1.2.1 Blade Facility I.D.South Entry 4Facility I.D.Sign Type 1.3.2 LI O N S H E A D W E L C O M E C E N T E R BLDG. SIGNAGE & GRAPHICSDesign Intent4 October, 2012 Lionshead Welcome CenterTown of Vail PROJECT Greg Hall, Town of Vail CLIENT CONTACT HB, JM, DT TEAM Secondary Project I.D.Level 1 North Elevation 1.1.2 1112 Pearl Street Boulder, CO 80302TEL 303.447.8202 FAX 303.440.7069www.commarts-boulder.comwww.stantec.com These drawings express visual design intent only. Final engineering, materials and fabrication shall remain the responsibility of the fabricator. Existing sconce fixtures Bottom edge of concrete garage structure. 1/4" Thick plate stock sign panel. Panel has flush backer frame of 2" angle stock. 3" Fabricated cabinet at top, enclosed at sides, and open bottom face, houses LED illumination (Winona Winline LED 103W*) to wash front face, top to bottom. If multiple fixtures are required, hot or dark spots are not acceptable. Entire assembly painted M.1 (Corten) color. Face has cut-out 1/4" plate metal letters, painted P.4 (White). Letters are mechanically fastened to sign panel. Sign panel is pinned 1/2" off wall surface by 2" Dia. cylinder clad studs on rear face, no visible fasteners on face. Information icon mounted to wall adjacent to sign assembly. 1/4" plate stock face painted M.1 (Corten) color is separated from 2" thick fabricated rear cabinet, painted to match, by a 1/2" thick layer of M.2 (acrylic with frosted finish returns). LED illumination inside cabinet provides an edge glow through acrylic. All conduit is to be concealed behind stone veneer.Venner to be replaced after installation. Fabricator to review applicable Architectural Drawings (available on line from Owner) for existing wall construc-tion details to ensure appropriate anchor connections. * http://www.winonalighting.com/products/winona_led/led_linear/103w LIONSHEAD VILLAGE Welcome Center LIONSHEAD VILLAGE Welcome Center 2"1/2"1/4"1/2" 3" 3"2" Cabinet at top, LED fixture within. Fixture as far away from surface as possible Letters fastened to face Cylinder clad studs.Cylinders ground to fit stone surface Stone wall surfaceSee Arch. Dwg’s for specific construction details Stone veneer of wall to be patched appropri-ately after installation 1 Elevation SCALE: 1/2"= 1'-0" 3 Section SCALE: 3"= 1'-0" 2 Photo Composite SCALE: NTS - 1 Key Plan Sign Section 1'- 6 " 1' - 6 " Panel Section Icon Section 5'- 3 " AF F 1'- 6 " 5'-8" 3"1'-6" 1/2" LI O N S H E A D W E L C O M E C E N T E R BLDG. SIGNAGE & GRAPHICSDesign Intent4 October, 2012 Lionshead Welcome CenterTown of Vail PROJECT Greg Hall, Town of Vail CLIENT CONTACT HB, JM, DT TEAM Transit Center I.D.North & South Elevations 1.1.3 1112 Pearl Street Boulder, CO 80302TEL 303.447.8202 FAX 303.440.7069www.commarts-boulder.comwww.stantec.com These drawings express visual design intent only. Final engineering, materials and fabrication shall remain the responsibility of the fabricator. 2 Photo Composite SCALE: NTSNorth Elevation 3 Elevation SCALE: 1/2"= 1'-0" 1 Photo Composite SCALE: NTSSouth Elevation 1/4" Thick plate stock sign panel. Panel has flush backer frame of 2" angle stock. 3" Fabricated cabinet at top, enclosed at sides, and open bottom face, houses LED illumination (Winona Winline LED 103W*) to wash front face, top to bottom. If multiple fixtures are required, hot or dark spots are not acceptable. to wash front face, top to bottom. Entire assembly painted M.1 (Corten) color. Face has cut-out 1/4" plate metal letters, painted P.4 (White). Letters are mechanically fastened to sign panel. Sign panel is pinned 1/2" off wall surface by 2" Dia. cylinder clad studs on rear face, no visible fasteners on face. Fabricator to review applicable Architectural Drawings (available on line from Owner) for existing wall construction details to ensure appropriate anchor connections. * http://www.winonalighting.com/products/winona_led/led_linear/103w Sign Type 1.3.3Single Pole mount blade icons Sign Type 1.3.2Wall mount blade icons LIONSHEAD VILLAGE Transit Center LIONSHEAD VILLAGE Transit Center 6'-0" 1' - 8 " 5'- 2 " LI O N S H E A D W E L C O M E C E N T E R BLDG. SIGNAGE & GRAPHICSDesign Intent4 October, 2012 Lionshead Welcome CenterTown of Vail PROJECT Greg Hall, Town of Vail CLIENT CONTACT HB, JM, DT TEAM Project Entry I.D.South ElevationEntry 3 1.2.1 1112 Pearl Street Boulder, CO 80302TEL 303.447.8202 FAX 303.440.7069www.commarts-boulder.comwww.stantec.com These drawings express visual design intent only. Final engineering, materials and fabrication shall remain the responsibility of the fabricator. 2 Elevation Detail SCALE: 1/4"= 1'-0"South Entry 3 1 Perspective SCALE: NTS South Entry 1 South Entry 2 South Entry 3 Secondary Project I.D. South Entry 4 3 Photo Composite SCALE: NTS Key Plan Framed Sign1/4" Thick plate stock sign panel. Panel has flush backer frame of 3" angle stock. 4 1/2" Fabricated cabinet at top, enclosed at sides, and open at bottom, houses LED illumination (Winona Winline LED 103W*) to wash front face, top to bottom. If multiple fixtures are required, hot or dark spots are not acceptable.to wash front face, top to bottom. Entire assembly painted M.1 (Corten) color. Face has cut-out 1/2" plate metal letters, painted P.4 (White). Letters are mechanically fastened to sign panel. Sign panel is suspended from canopy surface by (3) 3" square tube stock supports and 1/2" thick base plate. Supports “pierce” top of frame and connect to a lateral support member. Entire support assembly painted P.3 (Black). Fabricated IconInformation icon suspended adjacent to sign panel. 1/4" plate stock face painted M.1 (Corten) color is separated from 3" thick fabricated rear cabinet, painted to match, by a 1/2" thick layer of M.2 (acrylic with frosted finish returns). LED illumination inside cabinet provides an edge glow through acrylic. Icon base plate wraps canopy arm members. Fabricator to review applicable Architectural Drawings (available on line from Owner) for existing canopy construction details to ensure appropriate anchor connections. * http://www.winonalighting.com/products/winona_led/led_linear/103w Plan Section Sign to align with mullions in window beyond. Sign to align with mullions in window beyond. LIONSHEAD VILLAGE Welcome Center LIONSHEAD VILLAGE Welcome Center 6'-8"2'-0" 1'- 1 1 " 1' - 2 " ± VI F 10 ' - 6 " AF F 10 ' - 6 " AF F 1'-6" 1' - 0 " 3' - 3 " VIF 2'- 0 " 2'-8 1/4" 6'-8" LI O N S H E A D W E L C O M E C E N T E R BLDG. SIGNAGE & GRAPHICSDesign Intent4 October, 2012 Lionshead Welcome CenterTown of Vail PROJECT Greg Hall, Town of Vail CLIENT CONTACT HB, JM, DT TEAM Project Entry I.D.South ElevationEntry 3 1.2.1.2 1112 Pearl Street Boulder, CO 80302TEL 303.447.8202 FAX 303.440.7069www.commarts-boulder.comwww.stantec.com These drawings express visual design intent only. Final engineering, materials and fabrication shall remain the responsibility of the fabricator. 2 Elevation Detail SCALE: 3/4"= 1'-0" 3 Sections SCALE: 1 1/2"= 1'-0" 1 Perspectives SCALE: NTS Rear view of framed sign panel Sign is centered between canopy arms, icon is suspended below right pair of arms. Both align laterally.Boxed-in lateral support member on rear surface echoes light box on front. Canopy underside Base plate Support arm Light box Lateral structure member Support arm Letters on face Plate sign face Angle stock frame Canopy arm underside Corten face Lateral structure member Fabricated icon cabinet Plan Section Icon Section Sign Section LIONSHEAD VILLAGE Welcome Center 2'-8" 2'-8" 1'-9"3" 6'-8" 6'-8" 4 1 / 2 " 1'- 1 1 " 2' - 0 " 5" Eq.Eq. 1'-0" 1'- 0 " 7 1 / 2 " 2'-0" 1'-0"± VIF 3 3 / 4 " 1' - 0 " 1'- 4 " ± VI F 4 1 / 2 " 3" LI O N S H E A D W E L C O M E C E N T E R BLDG. SIGNAGE & GRAPHICSDesign Intent4 October, 2012 Lionshead Welcome CenterTown of Vail PROJECT Greg Hall, Town of Vail CLIENT CONTACT HB, JM, DT TEAM Entry I.D.Vail Recreatiion District 1.2.2 1112 Pearl Street Boulder, CO 80302TEL 303.447.8202 FAX 303.440.7069www.commarts-boulder.comwww.stantec.com These drawings express visual design intent only. Final engineering, materials and fabrication shall remain the responsibility of the fabricator. VAIL RECREATIONDISTRICT 2 Elevation Detail SCALE: 1/4"= 1'-0"Level 2 North Entry 1 Photo Composite SCALE: NTS Key Plan Sign positioned to clear door swing. Power access from Mechanical room Cabinet at top, LED fixture within Masked and enamel painted graphics on face panel Angle stock backer frame Cylinder clad studs.Cylinders ground to fit stone surface Stone wall surfaceSee Arch. Dwg’s for specific construction details Stone veneer of wall to be patched appropri-ately after installation 2"1/2"1/4"3 Elevation SCALE: 1"= 1'-0" Section Plan 1/4" Thick plate stock sign panel. Panel has flush backer frame of 2" angle stock. 3" Fabricated cabinet at top, enclosed at sides, and open bottom face, houses LED illumination (Winona Winline LED 103W*) to wash front face, top to bottom. Entire assembly painted M.1 (Corten) color. Face has 2-color masked and painted graphics, color P.4 (White) with color P.3 (Black) drop shadow. (Note- drop shadow outlines to include the overprinting white shapes, so there is no offset edge under the white). Sign panel is pinned 1/2" off wall surface by 2" Dia. cylinder clad studs on rear face, no visible fasteners on face. Fabricator to review applicable Architectural Drawings (available on line from Owner) for existing wall construction details to ensure appropriate anchor connections. * http://www.winonalighting.com/products/winona_led/led_linear/103w VAIL RECREATION DISTRICT VAIL RECREATION DISTRICT VAIL RECREATIONDISTRICT 2'-7" 3' - 8 " 3" 3'- 0 " 3'- 8 " 2'-6" 3"2" 1/2"1/4" LI O N S H E A D W E L C O M E C E N T E R BLDG. SIGNAGE & GRAPHICSDesign Intent4 October, 2012 Lionshead Welcome CenterTown of Vail PROJECT Greg Hall, Town of Vail CLIENT CONTACT HB, JM, DT TEAM Entry I.D.Vail Community Room 1.2.3 1112 Pearl Street Boulder, CO 80302TEL 303.447.8202 FAX 303.440.7069www.commarts-boulder.comwww.stantec.com These drawings express visual design intent only. Final engineering, materials and fabrication shall remain the responsibility of the fabricator. 2 Elevation Detail SCALE: 1/4"= 1'-0"Level 3 North Entry 3 Elevation SCALE: 1"= 1'-0" 1 Photo Composite SCALE: NTSLevel 3 North Entry Key Plan Plan Power access in JC 1/4" Thick plate stock sign panel. Panel has flush backer frame of 2" angle stock. 3" Fabricated cabinet at top, enclosed at sides, and open bottom face, houses LED illumina-tion (Winona Winline LED 103W*) to wash front face, top to bottom. Entire assembly painted M.1 (Corten) color. Face has 2-color masked and painted graphics, color P.4 (White) with color P.3 (Black) drop shadow. (Note- drop shadow outlines to include the overprinting white shapes, so there is no offset edge under the white). Sign panel is pinned 1/2" off wood wall surface by 2" Dia. cylinder clad studs on rear face, no visible fasteners on face. Fabricator to review applicable Architectural Drawings (available on line from Owner) for existing wall construction details to ensure appropriate anchor connections. * http://www.winonalighting.com/products/winona_led/led_linear/103w Sign Type 1.3.1s The Grand ViewThe Grand View 5' - 4 " AF F 3"2" 1/2" 3" 1'- 3 " 4'-2" LI O N S H E A D W E L C O M E C E N T E R BLDG. SIGNAGE & GRAPHICSDesign Intent4 October, 2012 Lionshead Welcome CenterTown of Vail PROJECT Greg Hall, Town of Vail CLIENT CONTACT HB, JM, DT TEAM Entry I.D.West ElevationGarage Entry 1.2.4 1112 Pearl Street Boulder, CO 80302TEL 303.447.8202 FAX 303.440.7069www.commarts-boulder.comwww.stantec.com These drawings express visual design intent only. Final engineering, materials and fabrication shall remain the responsibility of the fabricator. 2 Elevation Detail SCALE: 1/4"= 1'-0"West Garage Entry 3 Elevation SCALE: 3/4"= 1'-0"Information Panel 1 Photo Composite SCALE: NTS Key Plan Plan Drop Off Only Short Term Parking 1/4" Thick plate stock sign panel. Panel has flush backer frame of 3" angle stock. Entire assembly painted M.1 (Corten) color. Sign panel is externally illuminated by existing light fixture above. Face has cut-out 1/4" plate metal letters, painted P.4 (White). Letters are mechanically fastened to sign panel. Sign panel is fastened to wall surface by 2" Dia. cylinder clad studs on rear face, no visible fasteners on face. Information icon mounted to wall adjacent to sign assembly. 3/8" plate stock face painted M.1 (Corten) color is separated from 3" thick fabricated rear cabinet, painted to match, by a 3/4" thick layer of M.2 (acrylic with frosted finish returns). LED illumination inside cabinet provides an edge glow through acrylic. 1/2" Plate stock sign panel pinned off curved entry lintel. Channel stock tracks hold (2) changeable message panels, all painted P.3 (Black). 2-Layer icon panels mechanically fastened to sign panel at right, front layer painted P.1 (Dk. Lionshead Red), rear layer painted P.3 (Black). Fabricator to review applicable Architectural Drawings (available on line from Owner) for existing entry construction details to ensure appropriate anchor connections. Angled bracket clips on rear side of info panel connect to rolled entry beam. Two layer icon panels fastened to front face. Sign Type 1.7Clearance I.D. Sections Channel tracks Changeable panel 2-Layer icons Welcome Center LIONSHEAD VILLAGE Drop Off Only Short Term Parking - B - A A B 4'-0" 4'-0" 2'- 0 " 1'- 1 0 " Pa n e l 11 " 4" 2'- 2 " To t a l 10'-0" 2'- 6 " LI O N S H E A D W E L C O M E C E N T E R BLDG. SIGNAGE & GRAPHICSDesign Intent4 October, 2012 Lionshead Welcome CenterTown of Vail PROJECT Greg Hall, Town of Vail CLIENT CONTACT HB, JM, DT TEAM Entry I.D.Garage EntryFreestanding Sign 1.2.5 1112 Pearl Street Boulder, CO 80302TEL 303.447.8202 FAX 303.440.7069www.commarts-boulder.comwww.stantec.com These drawings express visual design intent only. Final engineering, materials and fabrication shall remain the responsibility of the fabricator. 3 Photo Composite SCALE: NTSE. LionsHead Cir. 3 Perspective SCALE: NTS 2 Plan Detail SCALE: 1/16" = 1' - 0" 1 Elevation SCALE: 1/2" = 1'- 0" 2" Thick fabricated sign cabinet with 1/4" plate stock faces. 4" Fabricated light coves at top, both sides, enclosed at sides, and open bottom face, houses LED illumination (Winona Winline LED 103W*) to wash front face, top to bottom. If multiple fixtures are required, hot or dark spots are not acceptable. Entire assembly painted M.1 (Corten) color. Sign face has cut-out 1/4" plate metal letters, painted P.4 (White). Letters are mechanically fastened to sign panel. Face has 1/2" thick plate stock icon disk, painted P.4 (White) with 1/4" cut out arrow, painted P.3 (Black), both mechanically fastened. All white graphics to have V.1 (Reflective White vinyl) faces. Sign cabinet supported by (3) 2" square connection blocks. Connection blocks connect to 1/2" plate stock collars that wrap wood posts. Connection blocks and collars painted P.3 (Black). 10" Square rough sawn wood posts. Species and finish to match those on building (XXX). Posts to have foundation and protection from elelments as required for conditions. Fabricator to review applicable Architectural Drawings (available on line from Owner) for existing entry construction details to ensure appropriate anchor connections.* http://www.winonalighting.com/products/winona_led/led_linear/103w Sign Light fixture caisson Stone pedestal wall terminus Stone wall Limited use message positioned at top of forward corner of sign face, Welcome Center message gets second billing. Drop-Off & Short Term ParkingOnly Drop-Off & Short Term ParkingOnly Plan Side B message Section 8'-8" Total 6'-6" Sign Panel 10" Posts 11" Collars 11 " Co l l a r s 4"Lig h t Co v e 4" Ca b i n e t 2" Co r e c a b i n e t 4"Light Cove 2"4"Light Cove 4" 6" Cu r b 3'- 7 " Po s t s 2'- 8 " Si g n C a b i n e t 1'-6" 1' - 0 " to C u r b 2" LI O N S H E A D W E L C O M E C E N T E R BLDG. SIGNAGE & GRAPHICSDesign Intent4 October, 2012 Lionshead Welcome CenterTown of Vail PROJECT Greg Hall, Town of Vail CLIENT CONTACT HB, JM, DT TEAM Facility I.D.Flat Mount PanelsEntry 1 1.3.1 1112 Pearl Street Boulder, CO 80302TEL 303.447.8202 FAX 303.440.7069www.commarts-boulder.comwww.stantec.com These drawings express visual design intent only. Final engineering, materials and fabrication shall remain the responsibility of the fabricator. 1 Elevation Detail SCALE: 1/4"= 1'-0"South Entry 1 2 Elevation SCALE: 1"= 1'-0" 3 Photo Composite SCALE: NTS South Entry 1 South Entry 2 South Entry 3 Secondary Project I.D. South Entry 4Key Plan Rear face R= 2 5/8" Inset face R= 2" 6 Sept Add’n 4 Oct Change 1/4" Plate stock icon panel inset faces, painted P.1 (Dk. Lionshead Red). Inset faces fastened to rear faces with exposed vandal resistant fasteners, painted to match field. 1/4" Rear face and 1 1/2" flush angle stock backer frame painted P.3 (Black). Icon graphics are masked and painted P.4 (White). Icon assemblies individually pinned 1 1/2" apart and 1/2" off stone surface with 2" Dia. cylinder clad studs, (2) per panel, painted P.3 (Black). Cylinders ground as required to fit stone. Fabricator to review applicable Architectural Drawings (available on line from Owner) for existing wall construction details to ensure appropriate anchor connections. Section 1/2" 1 1/2"1/4"1/4" 2" Total Width 1'- 1 " In s e t F a c e 1'- 2 " Re a r F a c e 1'- 1 0 " Re a r F a c e 1'- 8 1 / 2 " In s e t F a c e 1 1/2"1 1/2"1'-2"1'-2"1'-2" Sign Type 1.4Level I.D. LI O N S H E A D W E L C O M E C E N T E R BLDG. SIGNAGE & GRAPHICSDesign Intent4 October, 2012 Lionshead Welcome CenterTown of Vail PROJECT Greg Hall, Town of Vail CLIENT CONTACT HB, JM, DT TEAM Facility I.D.Flat Mount PanelsEntry 2 1.3.1.2 1112 Pearl Street Boulder, CO 80302TEL 303.447.8202 FAX 303.440.7069www.commarts-boulder.comwww.stantec.com These drawings express visual design intent only. Final engineering, materials and fabrication shall remain the responsibility of the fabricator. 1 Elevation Detail SCALE: 1/4"= 1'-0"South Entry 2 2 Elevation SCALE: 1"= 1'-0" South Entry 1 South Entry 2 South Entry 3 Secondary Project I.D. South Entry 4 3 Photo Composite SCALE: NTS Key Plan 1/4" Plate stock icon panel inset faces, painted P.1 (Dk. Lionshead Red). Inset faces fastened to rear face with exposed vandal resistant fasteners, painted to match field. 1/4" Rear face and 1 1/2" flush angle stock backer frame painted P.3 (Black). Icon graphics are masked and painted P.3 (White). Icon assemblies individually pinned 1 1/2" apart and 1/2" off stone surface with 2" Dia. cylinder clad studs, (2) per panel, painted P.3 (Black). Cylinders ground as required to fit stone. Fabricator to review applicable Architectural Drawings (available on line from Owner) for existing wall construction details to ensure appropriate anchor connections. Rear face R= 2 5/8" Inset face R= 2" 5/8" 1 1/2" Section 1/2" 1 1/2"1/4"1/4" 2" Total Width 3" 6'-4" 1' - 2 " 1' - 1 " In s e t F a c e 1'- 2 " Re a r F a c e 5'-1/2" LI O N S H E A D W E L C O M E C E N T E R BLDG. SIGNAGE & GRAPHICSDesign Intent4 October, 2012 Lionshead Welcome CenterTown of Vail PROJECT Greg Hall, Town of Vail CLIENT CONTACT HB, JM, DT TEAM Facility I.D.Small Flat Mount Panels3rd Level North Entry 1.3.1.s 1112 Pearl Street Boulder, CO 80302TEL 303.447.8202 FAX 303.440.7069www.commarts-boulder.comwww.stantec.com These drawings express visual design intent only. Final engineering, materials and fabrication shall remain the responsibility of the fabricator. 1 Photo Composite SCALE: NTS 2 Elevation Detail SCALE: 3/8"= 1'-0"3rd Level North Entry 3 Elevation SCALE: 1"= 1'-0" Sign to align with top of Sign Type 1.2.3, Grand View I.D. Section 1.3.1s Is a smaller version of Sign Type 1.3.1 1/4" Plate stock icon panel inset faces, painted P.1 (Dk. Lionshead Red). Inset faces fastened to rear facew with exposed vandal resistant fasteners, painted to match field. 1/4" Rear face and 1 1/2" flush angle stock backer frame painted P.3 (Black). Icon graphics are masked and painted P.4 (White). Icon assembly pinned 1/2" off stone surface with 2" Dia. cylinder clad studs, (2) per panel, painted P.3 (Black). Fabricator to review applicable Architectural Drawings (available on line from Owner) for existing wall construction details to ensure appropriate anchor connections. 1/2" 1 1/2" 1/4"1/4" 9 1 / 8 " 10 " 10" 5' - 4 " 1' - 6 " 6' - 0 " LI O N S H E A D W E L C O M E C E N T E R BLDG. SIGNAGE & GRAPHICSDesign Intent4 October, 2012 Lionshead Welcome CenterTown of Vail PROJECT Greg Hall, Town of Vail CLIENT CONTACT HB, JM, DT TEAM Facility I.D.Blade Mount Icon PanelsEntry 4 1.3.2 1112 Pearl Street Boulder, CO 80302TEL 303.447.8202 FAX 303.440.7069www.commarts-boulder.comwww.stantec.com These drawings express visual design intent only. Final engineering, materials and fabrication shall remain the responsibility of the fabricator. 2 Side Elevation SCALE: 1/4"= 1'-0"South Entry 3 1 Plan SCALE: 1/4"= 1'-0"South Entry 3 3 Elevation SCALE: 1/4"= 1'-0" 2-Sided cabinet construction blade mount icon sign. 3" Thick fabricated icon shapes are supported by 6" high bracket arms, same thickness to 1/2" thick mounting plate. Mounting Plate to match height of icon(s). Entire assembly painted P.3 (Black). Sign fastened to stone wall surface with exposed 3/4" hex head fasteners, painted to match field. Both faces of icon shapes have inset 1/4" plate stock panels, painted P.1 (Dk. Lionshead Red). Inset faces fastened to rear facew with exposed countersunk vandal resistant fasteners, painted to match field. Faces of inset panels have masked and enamel painted graphics, P.4 (White). Fabricator to review applicable Architec-tural Drawings (available on line from Owner) for existing wall construction details to ensure appropriate anchor connections. Key Plan 1'-2" 1 1/2" 1/2"3" 9" 3 1/2" 4 Photo Composite SCALE: NTS 2'- 5 1 / 2 " 1' - 2 " 1'- 2 " 2' - 5 1 / 2 " 10 " 1 1 / 2 " LI O N S H E A D W E L C O M E C E N T E R BLDG. SIGNAGE & GRAPHICSDesign Intent4 October, 2012 Lionshead Welcome CenterTown of Vail PROJECT Greg Hall, Town of Vail CLIENT CONTACT HB, JM, DT TEAM Facility I.D.-Blade Mount Icon PanelsThird Level 1.3.2.2 1112 Pearl Street Boulder, CO 80302TEL 303.447.8202 FAX 303.440.7069www.commarts-boulder.comwww.stantec.com These drawings express visual design intent only. Final engineering, materials and fabrication shall remain the responsibility of the fabricator. 1 Elevation Detail SCALE: 1/4"= 1'-0"Level 3 Northeast Elev. 2 Photo Composite SCALE: NTS Key Plan Side Elevation VAIL Community Room 2-Sided cabinet construction blade mount icon sign. 3" Thick fabricated icon shapes are supported by 6" high bracket arms, same thickness to 1/2" thick mounting plate. Mounting Plate to match height of icon(s). Entire assembly painted P.3 (Black). Sign fastened to stone wall surface with exposed 3/4" hex head fasteners, painted to match field. Both faces of icon shapes have inset 1/4" plate stock panels, painted P.1 (Dk. Lionshead Red). Inset faces fastened to rear faces with exposed vandal resistant fasteners, painted to match field. Faces of inset panels have masked and enamel painted graphics, P.4 (White). Fabricator to review applicable Architectural Drawings (available on line from Owner) for existing canopy construction details to ensure appropriate anchor connections. Facility I.D.Sign Type 1.2.3 1'- 2 " 3' - 9 " 3' - 9 " 9" LI O N S H E A D W E L C O M E C E N T E R BLDG. SIGNAGE & GRAPHICSDesign Intent4 October, 2012 Lionshead Welcome CenterTown of Vail PROJECT Greg Hall, Town of Vail CLIENT CONTACT HB, JM, DT TEAM Facility I.D.-Blade Mount Icon PanelsInterior Variation 1.3.2.3 1112 Pearl Street Boulder, CO 80302TEL 303.447.8202 FAX 303.440.7069www.commarts-boulder.comwww.stantec.com These drawings express visual design intent only. Final engineering, materials and fabrication shall remain the responsibility of the fabricator. 1 Elevation Detail SCALE: 3/8"= 1'-0"Level 1 East Interior Elevation 2 Photo Reference SCALE: NTS Header wall to have wood trim at bottom, code requ’d EXIT sign and access panel for fireplace damper. Sign assembly to fasten to side of fireplace 2-Sided cabinet construction blade mount icon sign. 3" Thick fabricated icon shapes are supported by 6" high bracket arms, same thickness to 1/2" thick mounting plate. Mounting Plate to match height of icon(s). Entire assembly painted P.3 (Black). Both faces of icon shapes have inset 1/4" plate stock panels, painted P.1 (Dk. Lionshead Red). Inset faces fastened to rear shapes with exposed countersunk vandal resistant fasteners, painted to match field. Faces of inset panels have masked and enamel painted graphics, P.4 (White). Fabricator to review applicable Architec-tural Drawings (available on line from Owner) for existing wall construction details to ensure appropriate anchor connections. Key Plan Side Elevation Side A Side B 1'- 2 " 1 1 / 2 " 2' - 5 1 / 2 " 2' - 5 1 / 2 " 9" LI O N S H E A D W E L C O M E C E N T E R BLDG. SIGNAGE & GRAPHICSDesign Intent4 October, 2012 Lionshead Welcome CenterTown of Vail PROJECT Greg Hall, Town of Vail CLIENT CONTACT HB, JM, DT TEAM Facility I.D.-Blade Mount Icon PanelsSingle Tapering Pole Assembly 1.3.3 1112 Pearl Street Boulder, CO 80302TEL 303.447.8202 FAX 303.440.7069www.commarts-boulder.comwww.stantec.com These drawings express visual design intent only. Final engineering, materials and fabrication shall remain the responsibility of the fabricator. 2 Elevation SCALE: 3/8"= 1'-0" 1 Photo Composite SCALE: NTSTransit Center, South Elevation Plan1.3.3 2-Sided cabinet construction icon signs fastened to a clustered pole assembly. 3" Thick fabricated icon shapes are supported by 10" high bracket arms, same thickness that fasten between the members of the clustered pole assembly. Entire assembly painted P.3 (Black). Both faces of icon shapes have inset 1/4" plate stock panels, secured with mechanical fasteners, painted P.1 (Dk. Lionshead Red). Faces of inset panels have masked and enamel painted graphics, P.4 (White). (4) or (1) Tapering poles, painted P.3 (Black) secured together by (4) 1/4" plate stock bands, painted P.2 (Lionshead Anthracite). Second band from the bottom has cut-out 1/4" logo backer plate, painted P.3 (Black), with 1/4" raised logo, P.2 (Lionshead Anthracite), 2-sides. Domed cap at top. Precast colored concrete base. Ordinarily, a 14' pole mount assembly would look like this. The particular location where this sign occurs has a concrete abuttment, requiring a “sawed-off” variation, at right. 2'-0" 1'- 4 " 1'- 3 " 2'- 5 1 / 2 " 14 ' - 0 " “Sawed-off” variation at Transit Center LI O N S H E A D W E L C O M E C E N T E R BLDG. SIGNAGE & GRAPHICSDesign Intent4 October, 2012 Lionshead Welcome CenterTown of Vail PROJECT Greg Hall, Town of Vail CLIENT CONTACT HB, JM, DT TEAM Facility I.D.-Blade Mount Icon PanelsExisting Pole Assembly 1.3.4 1112 Pearl Street Boulder, CO 80302TEL 303.447.8202 FAX 303.440.7069www.commarts-boulder.comwww.stantec.com These drawings express visual design intent only. Final engineering, materials and fabrication shall remain the responsibility of the fabricator. 2-Sided cabinet construction icon signs fastened to existing posts. 3" Thick fabricated icon shapes are supported by 10" high bracket arms, same thickness that fasten to a compression cuff that secures to pole. Entire assembly painted P.3 (Black). In each case, pole Dia. will vary, VIF each location for compression cuff. Both faces of icon shapes have inset 1/4" plate stock panels, secured with mechanical fasteners, painted P.1 (Dk. Lionshead Red). Faces of inset panels have masked and enamel painted graphics, P.4 (White). Existing post is open at top. Sign Fabricator to add a domed cap to existing post. 1 Elevation SCALE: 1/2"= 1'-0" Sign Type 1.3.4xExisting Post Blade Mount Facility I.D. 1'- 2 " 10 ' - 6 " 13 ' - 0 " ± 1'- 3 " LI O N S H E A D W E L C O M E C E N T E R BLDG. SIGNAGE & GRAPHICSDesign Intent4 October, 2012 Lionshead Welcome CenterTown of Vail PROJECT Greg Hall, Town of Vail CLIENT CONTACT HB, JM, DT TEAM Level I.D. 1.4 1112 Pearl Street Boulder, CO 80302TEL 303.447.8202 FAX 303.440.7069www.commarts-boulder.comwww.stantec.com These drawings express visual design intent only. Final engineering, materials and fabrication shall remain the responsibility of the fabricator. 1 Elevation Detail SCALE: 3/8"= 1'-0"Level 1 East Interior Elevation 2 Elevation SCALE: 1 1/2"= 1'-0" 3 Photo Composite SCALE: NTS Section 1/2" 1 1/2"1/2" 1/4" Plate stock icon panel inset faces, painted P.1 (Dk. Lionshead Red). Inset faces fastened to rear faces with exposed countersunk vandal resistant fasteners, painted to match field. 1/4" rear face and 2" flush angle stock backer frame, painted P.3 (Black). Icon graphics are masked and painted P.4 (White). Icon assemblies individually pinned 1/2" off stone surface with 2" Dia. cylinder clad studs, (2) per panel, painted P.3 (Black). Cylinders ground as required to fit stone. Fabricator to review applicable Architectural Drawings (available on line from Owner) for existing wall construction details to ensure appropriate anchor connections. Signs located inside the garage, viewed when exiting the garages, include the “Do you Remem-ber....” message. Sign Type 1.3.1Facility I.D.Sign Type 1.4.1Level I.D. Signs located on the exterior of the garages, viewed from the street, do not include that message. (This variation is currently used only at theVail Village parking structure) 1'- 8 1 / 2 " In s e t F a c e 1'- 1 0 " Re a r F a c e 1'-10" LI O N S H E A D W E L C O M E C E N T E R BLDG. SIGNAGE & GRAPHICSDesign Intent4 October, 2012 Lionshead Welcome CenterTown of Vail PROJECT Greg Hall, Town of Vail CLIENT CONTACT HB, JM, DT TEAM Small Level I.D. 1.4s 1112 Pearl Street Boulder, CO 80302TEL 303.447.8202 FAX 303.440.7069www.commarts-boulder.comwww.stantec.com These drawings express visual design intent only. Final engineering, materials and fabrication shall remain the responsibility of the fabricator. Vail Recreation DistrictImagination StationVRD Community Programming LionsHead VillageWelcome Center The Grand ViewTransit Center LionsHead VillageWelcome Center LionsHead VillageWelcome Center LionsHead VillageWelcome Center 2 Elevation Detail SCALE: 3/8"= 1'-0" 1 Photo Composite SCALE: NTSDrop-Off Area, Level 1 3 Photo Composite SCALE: NTSLevel 2 Core Entry 4 Photo Composite SCALE: NTSLevel 2 Stair Level 1 Core Entry Level 2Core Entry Level 2Stairwell EntrySouth Wall Level 2Stairwell EntryNorth Wall 1 Elevation SCALE: 1"= 1'-0"Section 1/2"1 1/2" 1/4"1/4" 9 1 / 4 " 10 " Signs viewed when exiting the garages include the “Do you Remember....” message. Backer frame is to be notched to accept the sign below. Signs located on the exterior of the garages, viewed from the street, do not include that message. When this sign type appears as a modifier to another sign (Sign Type 3.2.3), this smaller size is to be used: 10". 1/4" Plate stock icon panel inset faces, painted P.1 (Dk. Lionshead Red). Inset faces fastened to rear faces with countersunk vandal reistant fasteners, painted to match field. 1/4" Rear face and 1 1/2" flush angle stock backer frame painted P.3 (Black). Backer frame is to be notched to accept the sign below. Icon graphics are masked and painted P.4 (White). Icon assemblies individually pinned 1/2" off stone surface with 2" Dia. cylinder clad studs, (2) per panel, painted P.3 (Black). Cylinders ground as required to fit stone. Fabricator to review applicable Architectural Drawings (available on line from Owner) for existing wall construction details to ensure appropriate anchor connections. See note at right 10" LI O N S H E A D W E L C O M E C E N T E R BLDG. SIGNAGE & GRAPHICSDesign Intent4 October, 2012 Lionshead Welcome CenterTown of Vail PROJECT Greg Hall, Town of Vail CLIENT CONTACT HB, JM, DT TEAM Garage Entry Clearance I.D. 1.7 1112 Pearl Street Boulder, CO 80302TEL 303.447.8202 FAX 303.440.7069www.commarts-boulder.comwww.stantec.com These drawings express visual design intent only. Final engineering, materials and fabrication shall remain the responsibility of the fabricator. Sign Type 1.2.4 Garage Entry I.D. 1 Elevation Detail SCALE: 1/4"= 1'-0"West Elevation Drop Off Only 30 Min. Parking Welcome Center LIONSHEAD VILLAGE 4" Dia. thin wall aluminum tube suspended from 1/8" braided stainless steel aircraft cable. Tube is painted P.1 (Dk Lionshead Red) vinyl and graphics are V.1 (Reflective White). 7'- 5 " 8'-0" 2 Photo Composite SCALE: NTS LI O N S H E A D W E L C O M E C E N T E R BLDG. SIGNAGE & GRAPHICSDesign Intent4 October, 2012 Lionshead Welcome CenterTown of Vail PROJECT Greg Hall, Town of Vail CLIENT CONTACT HB, JM, DT TEAM Directory-Elevator Lobby 2.1.1 1112 Pearl Street Boulder, CO 80302TEL 303.447.8202 FAX 303.440.7069www.commarts-boulder.comwww.stantec.com These drawings express visual design intent only. Final engineering, materials and fabrication shall remain the responsibility of the fabricator. 1 Elevation Detail SCALE: 3/8"= 1'-0" 2 Layouts SCALE: 1"= 1'-0" 3 Photo Composite SCALE: NTS Section 2nd Surface Vinyl Graphics 1/4" Plate metal sign backer panel pinned 1/4" off (smooth) wall surface. Panel has M.1 (Corten) finish, specific floor band painted P.1 (Dk. Lionshead Red). Returns painted P.1 (Dk. Lionshead Red) or M.1 (Corten), depending upon its adjacent face color. 1/4" x 11/2" Attachment straps at top and bottom. Straps painted P.3 (Black). 1/2" Dia. vandal resistant head fasteners, painted to match field. Attachment straps secure .060 non-glare acrylic sheet, same size as sign backer panel. Acrylic has second surface graphics, V.3 (Matte White). 1'-6" 2' - 6 " Street Level Garage Level 1 Level 2 Level 3 5'- 9 " AF F 1'-6" 2'- 6 " LI O N S H E A D W E L C O M E C E N T E R BLDG. SIGNAGE & GRAPHICSDesign Intent4 October, 2012 Lionshead Welcome CenterTown of Vail PROJECT Greg Hall, Town of Vail CLIENT CONTACT HB, JM, DT TEAM Directory-Elevator Cabs 2.1.2 1112 Pearl Street Boulder, CO 80302TEL 303.447.8202 FAX 303.440.7069www.commarts-boulder.comwww.stantec.com These drawings express visual design intent only. Final engineering, materials and fabrication shall remain the responsibility of the fabricator. 1 Elevation Detail SCALE: 3/8"= 1'-0" 2 Elevation Section SCALE: Half Size 3 Photo Composite SCALE: NTS 321L Lobby/Street The Grand View Vail Recreation DistrictImagination StationVRD Community Programming Drop-OffShort Term Parking Lionshead Village 2nd Surface Vinyl Graphics1/4" Plate aluminum sign backer panel adhered (mechanically fastened if possible) to cab wall surface. Panel painted P.1 (Dk. Lionshead Red), Returns painted P.1 (Dk. Lionshead Red) or P.3 (Black), depending upon its adjacent face color. 1/4" x 1" Attachment straps at top and bottom. Straps painted P.3 (Black). 1/2" Dia. vandal resistant head fasteners, painted to match field. Attachment straps secure .060 non-glare acrylic sheet, same size as sign backer panel. Acrylic has second surface graphics, V.3 (Matte White). Vandal resistant fasteners 1/8" Attachment strap .060 Non-glare acrylic, 2nd surface vinyl graphics 1/4" Backer panel Cab wall surface 8" 8" 10" 1"1" 1" LI O N S H E A D W E L C O M E C E N T E R BLDG. SIGNAGE & GRAPHICSDesign Intent4 October, 2012 Lionshead Welcome CenterTown of Vail PROJECT Greg Hall, Town of Vail CLIENT CONTACT HB, JM, DT TEAM Entry Door Graphics Glass Doors 2.2 1112 Pearl Street Boulder, CO 80302TEL 303.447.8202 FAX 303.440.7069www.commarts-boulder.comwww.stantec.com These drawings express visual design intent only. Final engineering, materials and fabrication shall remain the responsibility of the fabricator. 1 Elevation SCALE: 3/8"= 1'-0"South Entry 2 (“Cat Door”)Street Level Elevator Lobby 2 Elevation SCALE: 3/8"= 1'-0"South Entry 2Vestibule Entry 3 Elevation SCALE: 3/8"= 1'-0"South Entry 3Street Level Primary Entry 4 Elevation SCALE: 3/8"= 1'-0"South Entry 4Street Level Restroom Entry 5 Elevation SCALE: 3/8"= 1'-0"North Entry, 3rd LevelVestibule Entry 2 1 3 4 5 South Entry 2 South Entry 3 3rd Level North Vestibule Entry South Entry 4 Currently reads: Elevators & ADA Access Enter Here Automatic door decal Currently reads:Currently reads: Diagrammatic Key Plan Restrooms & Lockers Restrooms & Lockers TheGrand View LIONSHEAD VILLAGE Welcome Center LIONSHEAD VILLAGE Welcome Center LIONSHEAD VILLAGEWelcome Center LIONSHEAD VILLAGEWelcome Center Elevators & ADA Access to Parking Messages to be second surface machine-cut vinyl, V.3 (Frosted Crystal). Messages in Sign Package typeface are to replace any existing messages. LI O N S H E A D W E L C O M E C E N T E R BLDG. SIGNAGE & GRAPHICSDesign Intent4 October, 2012 Lionshead Welcome CenterTown of Vail PROJECT Greg Hall, Town of Vail CLIENT CONTACT HB, JM, DT TEAM Entry Door Graphics 50th Anniversary Temporary Patches 2.2c 1112 Pearl Street Boulder, CO 80302TEL 303.447.8202 FAX 303.440.7069www.commarts-boulder.comwww.stantec.com These drawings express visual design intent only. Final engineering, materials and fabrication shall remain the responsibility of the fabricator. 1 Elevation SCALE: 3/8"= 1'-0"South Entry 2 (“Cat Door”)Street Level Elevator Lobby 2 Elevation SCALE: 3/8"= 1'-0"South Entry 2Vestibule Entry 3 Elevation SCALE: 3/8"= 1'-0"South Entry 3Street Level Primary Entry 4 Elevation SCALE: 3/8"= 1'-0"South Entry 4Street Level Restroom Entry 5 Elevation SCALE: 3/8"= 1'-0"North Entry, 3rd LevelVestibule Entry 2 1 3 4 5 South Entry 2 South Entry 3 3rd Level North Vestibule Entry South Entry 4 2-Sided full color digitally printed logo on white vinyl applied second surface Diagrammatic Key Plan Restrooms Public Lockers Restrooms & Lockers TheGrand View LIONSHEAD VILLAGE Welcome Center LIONSHEAD VILLAGE Welcome Center LIONSHEAD VILLAGEWelcome Center LIONSHEAD VILLAGEWelcome Center Elevators & ADA Access to Parking Temporary logo decals applied to all glass entry doors: street level and Grand View room. 8 1/2" 1' - 0 " 4" LI O N S H E A D W E L C O M E C E N T E R BLDG. SIGNAGE & GRAPHICSDesign Intent4 October, 2012 Lionshead Welcome CenterTown of Vail PROJECT Greg Hall, Town of Vail CLIENT CONTACT HB, JM, DT TEAM VehicularDirectionalSingle Post 3.1.1 1112 Pearl Street Boulder, CO 80302TEL 303.447.8202 FAX 303.440.7069www.commarts-boulder.comwww.stantec.com These drawings express visual design intent only. Final engineering, materials and fabrication shall remain the responsibility of the fabricator. 2 Elevation SCALE: 3/8" = 1'-0" 1 Photo Composite SCALE: NTS Sign Type 1.2.5-Freestanding Sign Plate metal brand detail, every pole at 5'-0" AFF. Sign Type 1.2.4-Threshold Sign(not visible here) CDOT Class III sign assembly. 6'-0" x 6'-0" x 1/4" Aluminum sign panel. Face painted P.1 (Dk Lionshead Red) with V.1 (Reflective White) graphics. Sign supported by single tapering post assembly. Post, painted P.3 (Black) tapers from 8" at bottom to 4" at top. Post has (5) 6" bands of 1/2" plate stock, painted P.2 (Lionshead Anthracite). Second band from the bottom has cut-out 1/4" logo backer plate, painted P.3 (Black), with 1/4" raised logo, P.2 (Lionshead Anthracite), 2-sides. Top of post has domed cap. 2-Layer brand logo of 1/2" plate stock, 2-sides. Short TermParking Only Drop-Off Welcome Center 6'- 0 " 12 ' - 6 " 7'- 0 " LI O N S H E A D W E L C O M E C E N T E R BLDG. SIGNAGE & GRAPHICSConceptual Design4 October, 2012 Lionshead Welcome CenterTown of Vail PROJECT Greg Hall, Town of Vail CLIENT CONTACT HB, JM, DT TEAM PedestrianDirectional- Wall Mount 3.2.1 1112 Pearl Street Boulder, CO 80302TEL 303.447.8202 FAX 303.440.7069www.commarts-boulder.comwww.stantec.com These drawings express visual design intent only. Final engineering, materials and fabrication shall remain the responsibility of the fabricator. 1 Elevation Detail SCALE: 3/8"= 1'-0" Level 1 Core Entry Level 1 Core Entry Sign Tpe 1.4.1s Level 2Core Entry Level 2 Core Entry Level 2 Pedestrian EntrySouth Wall Level 2 Pedestrian EntryNorth Wall Level 2 Pedestrian EntrySouth Wall Level 2 Pedestrian EntryNorth Wall Vail Recreation DistrictImagination StationVRD Community Programming Lionshead VillageWelcome Center The Grand ViewTransit Center Lionshead VillageWelcome Center Lionshead VillageWelcome Center Lionshead VillageWelcome Center 1/4" Plate aluminum sign panel pinned 1 1/2" off (stone) wall surface. Panel painted P.1 (Dk. Lionshead Red). 1/4" x 11/2" Attachment straps at top and bottom. Straps painted P.3 (Black). 1/2" Dia. vandal resistant head fasteners, painted to match field. Messages are masked and enamel painted P.4 (White) Note- It is anticipated to use the ECO Transit logo where applicable LI O N S H E A D W E L C O M E C E N T E R BLDG. SIGNAGE & GRAPHICSDesign Intent4 October, 2012 Lionshead Welcome CenterTown of Vail PROJECT Greg Hall, Town of Vail CLIENT CONTACT HB, JM, DT TEAM Pedestrian Direc-tionalExisting Pole Mount Directional Panels 3.2.4 1112 Pearl Street Boulder, CO 80302TEL 303.447.8202 FAX 303.440.7069www.commarts-boulder.comwww.stantec.com These drawings express visual design intent only. Final engineering, materials and fabrication shall remain the responsibility of the fabricator. 2 Elevation SCALE: 1/2"= 1'-0" 1 Axonometric SCALE: NTS 3 Photo Composite SCALE: NTS Note: this sign type is of the same construction as Sign Type 1.3.4: Existing Pole Mount Facility I.D. As a directional sign, this type includes an arrow icon. 2-Sided cabinet construction blade mount icon signs fastened to an existing (light) pole. 3" Thick fabricated icon shapes are supported by 10" high bracket arms, same thickness that fasten to compression cuffs that wrap existing posts (post sizes will vary). Entire assembly painted P.3 (Black). Both faces of icon shapes have inset 1/4" plate stock panels, secured with countersunk vandal resistant mechanical fasteners, painted P.1 (Dk. Lionshead Red). Faces of inset panels have masked and enamel painted graphics, P.4 (White). Compression cuffs Bracket Arm Icon Frame Inset icon faces Painted Graphics 14 ' - 8 " To t a l 14 ' - 0 " Po l e s 8' - 0 " Min 1'- 2 " Ic o n F r a m e 1'- 3 1 / 2 " Ar r o w F r a m e 10 " Cu f f