HomeMy WebLinkAboutPRJ06-0144 B06-0089TOWN OF VAIL DEPARTMENT OF COMMUNITY DEVELOPMENT
75 S. FRONTAGE ROAD � i _ ��� � '��-!�-��� �' �"�
VAIL, CO 81657 \�� �
970-479-2138 �� 'l_�l (/��-- -�
NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES _
i_1:%�
--� j� _ ,i�:1--, -
ADD/ALT COMM BUILD PERMT Permit # B06-0089
Project #
Job Address: 241 E MEADOW DR VAIL
Location.......: VAIL VILLAGE PARKING STRUCTURE
Parcel No....: 210108227002
�°"�t�� ��`i ��
OWNER
APPLICANT
CONTRACTOR
TOWN OF VAIL
C/O FINANCE DEPT
75 S FRONTAGE RD
VAIL
CO 81657
B & B EXCAVATING,
P.O. BOX 1729
EDWARDS
CO 81632
License: 166-A
B & B EXCAVATING,
P.O. BOX 1729
EDWARDS
CO 81632
License: 166-A
04/20/2006
INC. 04/20/2006
INC. 04/20/2006
Status . . . : ISSUED
Applied .. . : 04/20/2006
Issued . . . : OS/24/2006
Expires. . . . . : 11 /20/2006
Phone: 970-926-3311
Phone: 970-926-3311
Desciption:
CONSTRUCTION OF E. MEADOW BOILER ROOM AND SNOWMELT
Occupancy: S-2
Type Construction: I-A
Valuation: 2,050,000.00 Revision Valuation: ??
Add Sq Ft: 0
*�*************�*******�**�:***�************************************* FEE SUMMARY **********************************************�*********�***
Building------> $ 9, 441. 2 5 Restuarant Plan Review--> $ o. 0 o Total Calculated Fees--> $15 , 58 i. 0 6
Plan Check---> $ 6,13 6. 81 Recreation Fee--------------> $ o. 0 o Additional Fees----------> i 5, 581. 0 6)
Investigation-> $0. 00 TOTAL FEES-------------> $15, 581. 06 Total Permit Fee---------> $0. 00
Will Call-----> $3.0o Payments-------------------> $0. o0
BALANCE DUE---------> $ 0. 0 0
**+**�**+*��***+**�*************��************�*****�************�*******************************�****�:**�*******************�*****�*****��****�*
Approvals:
Item: 05100 BUILDING DEPARTMENT
05/23/2006 cgunion Action: COND SEE COND
Item: 05400 PLANNING DEPARTMENT
05/08/2006 Warren Action: COND
Item: 05600 FIRE DEPARTMENT
Item: 05500 PUBLIC WORKS
05/10/2006 CTS Action: AP
��:***x:****�***��*************�**+*�****�*****�******************************************************�***********************�*********�**********
See the Conditions section of this Document for any conditions that may apply to this permit.
DECLARATIONS
I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot
plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply
with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design
review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto.
REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS�IN ADV, AcNICE Bn TELEPHONE AT 479-2149 OR AT OUR OFFICE FROM 8:00
AM - 4 PM. \ .� �� 1
SIGNA RE OF OWNER OR CONTRACTOR FOR HIMSELF AND OWNEF
*�*�***�**�*��*�*�**�***�**����*�*�**��*��**��**�**�����**�**�*�*��*�*����*�**��*��*�*�*��*�*�*�*�*�****
CONDITIONS OF APPROVAL
Permit #: B06-0089 as of OS-24-2006 Status: ISSUED
=��:�**�:***�:�*��*�*��*��*��x*�:**�:*�*�x*�x*�:**�:�x*�:��:**�x�*��****��*��*�x��x�*��x*�:�*�:*�*�:*�:*�:*�������x����x*�*�*��x*�
Permit Type: ADD/ALT COMM BUILD PERMT
Applicant: B& B EXCAVATING, INC.
970-926-3311
Job Address: 241 E MEADOW DR VAIL
Location: VAIL VILLAGE PARKING STRUCTURE
Parcel No: 210108227002
Description: .
CONSTRUCTION OF E. MEADOW BOILER ROOM AND SNOWMELT
Applied: 04/20/2006
Issued: OS/24/2006
To Expire: 11/20/2006
*�x*�:�*�x*�x*�:*��x*�:**�*�x*��:�*�x��*�:�x�*�*��x��:***�x*�:�Conditions:**��x�*���:***:x*:x*����x****�*�*�*:x�*�x*�:*��:*�x�*��:*�x*
Cond: 1
(FIRE): FIRE DEPARTMENT APPROVAL IS REQUIRED BEFORE ANY
WORK CAN BE STARTED.
Cond: 12
(BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE
COMPLIANCE.
Cond: CON0007993
Approval of this building permit extends to the
installation of the new boiler and associated vents on the
Vail parking structure, and the installation of snow melt
mains along East Meadow Drive. No streetscape improvements
are approved as a part of this building permit.
Cond: CON0007995
The applicant shall replace all damaged and removed
vegetation and trees caused by the installation of the snow
melt boiler mains through the existing landscape bed on the
west side of the structure with plant material of the same
size prior to requesting any final inspections.
Cond: CON0008080
CONDITIONS OF APPROVAL:
1) GAS VENT TERMINATION SHALL COMPLY WITH IFGC 503.6.6
2) DECORATIVE SHROUDS SHALL NOT BE INSTALLED AT VENT
TERMINATIONS UNLESS LISTED PER IFGC 503.6.6.1
3) BOILER VENT OFFSET SHALL COMPLY WITH IFGC 503.6.4
4) EQUIPMENT HAVING AN IGNITION SOURCE SHALL BE ELEVATED
MINIMUM 18" ABOVE THE GARAGE FLOOR PER IFGC 305.3
5) EF-1 COMBUSTION AIR FAN SHALL BE INTERLOCKED WITH
APPLIANCES PER IFGC 304.9.2
Cond: CON0008086
SPECIAL INSPECTION REQURIED FOR CONCRETE, STRUCTURAL
WELDING AND MSE WALL CONSTRUCTION PER IBC CH. 17.
0
d ��
APPLICATION WILL NOT BE ACCEPTED IF INCOMPLETE OR UNSI
Pro�ect #. �
„ � Building Permit #: • �
. � .� � 9•, fl�-��9,��d9_{I�Spe±ci,oris;)
. ���,
� � _,�.
������ 1 TOWN OF VAIL BUILDING PERMIT APPLICATION
Separate Permits are required for electrical, plumbing, mechanical, etc.!
75 S. Frontage Rd.
Vail, Colorado 81657
CONTRACTOR INFORMATION
COMPLETE VALUATIONS FOR BUILDING PERMIT
For Parcel # Contact Eagle County Assessors O�ce at 970-328-8640 or visit www.eaqle-county.com
�arc�l�# �. �� � a �y 2..�.� i� � � ��f� �l�l�l (.� � � i, I 0 � l �
Job Name: L, . I�i(,!i��iowJ �o I.�:2�t_ �00 �$ Job Address:�u {�
.S�Du�McR.T 7� L�h./r'�C:l4�OkJ �,Q/ v�
Legal Description -�Lo�� ' � Block: -�'' Filing: � � � Subdivision: ��} /� � L.(�,�,�"
Owners Name: ��� � � ���� Address: `:��y' �-�� �,��.� Phone: ��j _ �—�
�Q
neer:
.,. �y�CO
�, Address:p,���� ��U1N��B.,�E/�� Phone:
Z!n! �em,�lv_ � t-E�_ rra.„rr S �il-. F ,, — `t� �
work: �/��i�GC. �iL�'�. �'oc� .z'r� f%i}�C.. �i Gk�. � Pi4,t��/N� ;
�- � � �1 �Dor� D'�.1 � �" ;�v+krM r� a. r �
Work Class: New ( ) Addition ( ) Remodel ( ) Repair ( ) Demo ( ) Other ( )
Work Type: Interior () Exterior () Both (� Does an EHU exist at this location: Yes () No ()
Type of Bldg.: Single-family ( ) Two-family ( ) Multi-family ( ) Commercial (�(') Restaurant ( ) Other ( )
No. of Existing Dwelling Units in this building: No. of Accommodation Units in this building:
No/Type of Fireplaces Existing: Gas Appliances () Gas Logs () Wood/Pellet () Wood Burning ()
No/Type of Fireplaces Proposed: Gas Appliances () Gas Loqs () Wood/Pellet () Wood Burning (NOT ALLOWED
Does a Fire Alarm Exist: Yes (�() No () Does a Fire Sprinkler System Exist: Yes (�) No ()
FOR OFFICE USE ONLY
� � � �I �� -c
D
A�� z � Zoos
p TOWfV OF VAIL
F:\cdev\FORMS\Permits\Building\building�ermit.DOC Page 1 of 16 02/09/2005
Questions? Call the Building Team at 479-2325
.
�:
��'�'��' ��, ' Buildinq Permit Submittal Checklist
Department of Community Development
Project Name: � , /�i�� /�0 t,c� /'3� /C. L`�C. /?�o r�'t � .��1 du1 v-i L'�Z. 'f—
Project Address: � Y! L� /"1 L�4,D� r.J ��f � U�
✓ This Checklist must be completed before a Building Permit application is
acceQted.
❑ All pages of application is complete
o Has DRB approval obtained (if required) Provide a copy of approval form
❑ Plan Check Fee required at submittal for projects valued over $100,000.00 (see attached fee
schedule)
❑ Complete site plan submitted
❑ Public Way Permit application included if applicable (refer to Public Works checklist)
❑ Staging plan included (refer to Public Works checklist) No dumpster,aarkin4 or material storaqe
allowed on roadwavs and shoulders without written approval
❑ Asbestos test and results submitted if demolition is occurring
❑ Architect stamp and signature (All Commercial and Multi family)
❑ Full floor plans including building sections and elevations(3 sets for remodels, 4 sets of plans for SFR
and Duplex, 5 sets of plans for Multi-Family and Commercial Buildings)
❑ Window and door schedule
❑ Full structural plans, including design criteria (i.e.loads)
❑ Structural Engineer stamp and signature on structural plans (All Commercial and Multi Family)
❑ Soils Report must be submitted prior to footing inspection
❑ Fire resistive assemblies specified and penetrations indicated
❑ Smoke detectors shown on plans
❑ Types and quantity of fireplaces shown
A licant's Si nature: ,'�
pp 9
Date of submittal:
Received By:
��1
F:\cdev\FORMS\Permits\Building\building,�ermit.DOC Page 2 of 16 02/09/2005
�
How it relates to Building Permits:
➢ Fill out the attached check list with the Building Permit Application.
If yes was answered to any of the questions then a"Public Way" permit is required. You can pick up an
application at either Community Development, located at 75 South Frontage Road or Public Works, located at
1309 Elkhorn Drive.
➢ Notice sign-offs for utility companies. ALL utilities must field verify (locate) respective utilities prior to signing
application. Some utility companies require up to 48 hours notice to schedule a locate.
➢ A construction trafFic control/staging plan must be prepared on a separate sheet of paper. An approved site plan
may also be used. This plan will show locations of all traffic control devices (signs, cones, etc.) and the work
zone, (area of construction, staging, etc.). This plan will expire on November 1� and will need to be resubmitted
for consideration for approval through the winter. Be aware that your resubmission for winter may be denied
depending on the location of construction.
➢ Sketch of work being performed must be submitted indicating dimensions (length, width and depth of work).
This may be drawn on the traffic control plan or a site plan for the job.
➢ Submit completed application to the Public Works office for review. If required, locates will be scheduled for the
Town of Vail electricians and irrigation crew. The locates take place in the morning, but may require up to 48
hours to perform.
➢ The Public Works Construction Inspector will review the application and approve or deny the permit. You will be
contacted as to the status and any requirements that may be needed. Most permits are released 48 hours of
being received, but please allow up to one (1) week to process.
➢ As soon as the permit is approved, the Building Department will be notified, allowing the'�Building Permit" to be
released. Please do not confuse the ��Public Way Permit" with the "Building Permit".
➢ NOTE: The above process is for work in a public way ONLY. Public Way Permits are valid only until
November 15th. A new Public Way Permit is required each year if work is not complete. Re-
application each November 15t`' does not mean an automatic renewal.
I have rea and understand the above.
Signature
�{—��— Z�Jfl �a
{`
�
���� �� ��� y
Date Signed
F:\cdev\FORMS\Permits\Building\building�ermit.DOC Page 9 of 16 OZ/09/2005
�
*.
�
�l�� �� �� }
MATERIAL STORAGE AND CONSTRUCTION PARKING
Please read and check off each of the items below.
(Copies of complete text are available upon request)
CODE 5-2-10: DEPOSITS ON PUBLIC WAYS PROHIBITED
❑ Unlawful deposits: Subject to subsection C thereof, it is unlawful for any person to litter, track or deposit, or cause to
be littered, tracked or deposited, sand, gravel, rocks, mud, dirt, snow, ice, or any other debris or material upon any
street, sidewalk, alley or public place, or any portion thereof.
❑ Notice; Abatement: The Director of Public Works may notify and require any person who violates or causes another
to violate the provision of subsection A hereof, or who has in the Director's employment a person who violates or
causes another to violate the same, top remove such sand, gravel, rocks, mud, dirt, snow, ice or any other debris or
material within twenty four (24) hours after receipt of said notice by the Director of Public Works. In the event the
person so notified does not comply with the notice within the period of time herein specified, the Director of Public
Works, or other authorized agent, may cause any such sand, gravel, rocks, mud, dirt, snow, ice, debris or any other
material to be removed from any street or alley at the expense of the notified.
❑ Summons and Penalty: As an alternative to the notice for removal provided in subsection B above, any person
who violates or causes another to violate the same, may be issued a summons to appear before the Municipal Court of
the Town for said violations, and upon being found guilty of a violation hereunder be punished as provided in Section
1-4-1 of this code.
❑ Notice and Penalty: It is unlawful for any person to fail or refuse to comply with the notice of the Director of Public
Works as provided in subsection B hereof, and any such person shall, in addition to payment of the expense of removal
incurred by the Director of Public Works, as provided in subsection B hereof, upon being found guilty of a violation
hereunder, be punishable as provided in Section 1-4-1 of this Code. (1997 Code: Ordinance 6(1979).
CODES 7-3A-1 AND 7-3A-3: PARKING OBSTRUCTING TRAFFIC & IMPOUNDMENT AUTHORIZED
❑ No person shall park any vehicle upon a street or at any other place within this Municipality in such a manner or under
such conditions as to interfere with the free movement of vehicular traffic or proper street or highway maintenance.
(Ord. 2(1968) § 1)
❑ Whenever any police officer finds a vehicle attended or unattended, standing upon any portion of a street or upon any
place within this Municipality in such a manner as to constitute a violation of any section of this Article, or left
unattended for a period of twenty four (24) hours or more and presumed to be abandoned under the conditions
prescribed by Colorado Revised Statutes section 42-4-1102, as amended, the officer shall require the vehicle to be
removed or cause it to be removed and placed in storage in the nearest garage or other place of safety designated or
maintained by this Municipality, and the charges for towing and storage of such vehicle shall be charged to the owner
of the vehicle in addition to a ten dollar ($10) impoundment charge. (Ord. 2(1968) § 3: Ord. 28(1981) § 1)
I have read and will comply with the above code provisions: l� �%4't�-��
rint ame
Signature
Position or Relationship to Project: �(,� �- �,JrE-�(� .
Date Signed: —[ " i� � � �
F:/everyone/forms/bldperm7
F:\cdev\FORMS\Permits\Building\building�ermit.DOC Page 11 of 16 02/09/2005
TOWN OF VAIL
75 S. FRONTAGE ROAD
VAIL, CO 81657
970-479-2138
Job Address:
Location..... :
Parcel No...:
Legal Description:
Project No :
DEPARTMENT OF COMMUNITY DEVELOPMENT
NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES
MECHANICAL PERMIT
241 E MEADOW DR VAIL
VAIL VILLAGE PARKING STRUCTURE
210108227002
OWNER TOWN OF VAIL
C/O FINANCE DEPT
75 S FRONTAGE RD
VAIL
CO 81657
CONTRACTOR R& H MECHANICAL LLC
PO BOX 810
EAGLE
CO 81631
License: 184-M
05/02/2006
Permit #
Status . . . .
Applied . . :
Issued . . .
Expires . ..
M06-0126
ISSUED
OS/02/2006
OS/24/2006
11 /20/2006
05/02/2006 Phone: (970) 328-2699
Desciption: SNOWMELT SYSTEM IN STREETS; MAIN LINES, TEES, VALVES,
RADIANT TUBING AND MAINFOLD BOXES
V aluation: 1, 500, 000.00
Fireplace Information: Restricted: # of Gas Appliances: 0 {i of Gas Logs: 0 N of Wood Pellet: 0
�***********************************�******************************* FEE SUMMARY ****************�**********�********************************
Mechanical---> $30, 000.0o Restuarant Plan Review--> $0. 00 Total Calculated Fees---> $37, 503 . 00
Plan Check---> $7, 500. 00 TOTAL FEES--------------> $37, 503.00 Additional Fees-----------> 37, 503 . 00)
Investigation-> $ 0. 0 0 Total Pernut Fee----------> $ o. 0 0
Will Call-----> $ 3. o o Payments-----------------> $ o. 0 0
BALANCE DUE---------> $0. 00
***********************�*************************************************************�**********�***********�****��***********�****���***********
Item: 05100 BUILDING DEPARTMENT
05/23/2006 cgunion Action: AP
Item: 05600 FIRE DEPAR.TMENT
CONDITION OF APPROVAL
Cond: 12
(BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE.
Cond: 22
(BLDG.): COMBUSTION AIR IS REQUIRED PER CHAPTER 7 OF THE 2003 IMC AND SECTION
304 OF THE 2003 IFGC AS MODIFIED BY TOWN OF VAIL.
Cond: 23
(BLDG.): BOIILER INSTALLATION MUST CONFORM TO MANUFACTURER'S INSTRUCTIONS AND
CHAPTER 10 OF THE 2003 IMC.
Cond: 25
(BLDG.): GAS APPLIANCES SHALL BE VENTED ACCORDING TO CHAPTER 5 OF THE 2003 IFGC.
Cond: 29
(BLDG.): ACCESS TO MECHANICAL EQUIPMENT MUST COMPLY WITH CHAPTER 3 OF THE 2003
IMC AND CHAPTER 3 OF THE 2003 IFGC..
Cond: 31
(BLDG.): BOILERS SHALL BE MOUNTED ON FLOORS OF NONCOMBUSTIBLE CONST. UNLESS
LISTED FOR MOUNTING ON COMBUSTIBLE FLOORING.
Cond: 32
(BLDG.): PERMIT,PLANS AND CODE ANALYSIS MUST BE POSTED IN MECHANICAL ROOM PRIOR
TO AN INSPECTION REQUEST.
Cond: 30
(BLDG.): BOILER ROOMS SHALL BE EQUIPPPED WITH A FLOOR DRAIN OR OTHER APPROVED
MEANS FOR DISPOSING OF LIQUID WASTE PER SECTION 1004.6.
***�****�***�*�*�****�*********************************************�*****************�*************�******************************�*************�
DECLARATIONS
I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot
plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply
with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design
review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto.
REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVAI�C� BY TELEPHONE AT 479-2149 OR AT OUR OFFICE FROM 8:00 AM - 4
PM. �'i n �) I ..
SIGNATURE OF OWNER OR CONTRACTOR FOR HIMSELF AND OWNEF
APPLICATION WILL NOT BE ACCEPTED IF INCOMPLETE OR UNSIGN�P (��.. �� ��
TOV Project #: �
Building Permit #: 1� p�� ^ p� �`7
�. ,. Mechanical Permit #: � � �
,7y���,�r� . 970-479-2149 (Inspectior�J�� ^ Ot Z /
� v tt i�,� fo
TOWN OF VAIL MECHANICAL PERMIT APPLICATION
75 S. Frontage R�. Permit will not be accepted without the following:
Vail, Colorado 81657
Prov3de Mechanical Room Layout drawn to scale to include:
❑ Mechanicat Room Dimensions
❑ Combustion Air Duct Size and Location
o Flue, Vent and Gas Line Size and Location
❑ Heat Loss Calcs.
❑ Equipment Cut/Spec Sheets
CONTRACTOR INFORMATION
COMPLETE VALUATION FOR MECHANICAL PERMIT Labor & Materials
MECHANICAL: $ ( � S�, 6p c7 . �"—
Contact Eag/e County Assessors O�ce at 970-328-8640 or visit www, eaqle-countv. com for Parce/ #
Parcel # Z, ! o l o g 2'L � o�- S�. !-� �'O c�.c,c3' �.o f o 3�i I__ _
)ob Name: C..=�7r�'"i c='w,pa�..� S T2c''�T�c'°Pc,s� II ]ob Address: •
C�c. s�s� z�/� C.�-tG�9-vow Q�2iuc:
�
Legal Description �ot:a�� Block: -- Filing: �! Subdivision: ✓��L vl���� r'��
Owners Name:�-�� oF v�y� � Address: 130 � CC ��,o,�,� Phone: �� _ 3�-6-- S$ y I
Engineer: B E�4 u p� N C�r+4n�zLr Address: P� .�o K� q U� � Phone: �� - g��, - 6/ ��
Detailed description of work: �.-�,�,;� �,',�,�..-.� ,.t.t� ,s �v,�,t,Qy
5n��4�I�t[�.T S`t'S i�G� l KJ S I 2-L,T(� `(� �'��l,;...fi- 7Ze.{3i..� c-
.,..,.a.�,�,id r���ca's
Work Class: New ( ) Addition ( ) Alteration ( ) Repair ( ) Other ( )
Boiler Location: Interior () Exterior () Other () Does an EHU exist at this location: Yes () No ()
Type of Bldg: Single-family ( ) Duplex ( ) Multi-family ( ) Commercial (� Restaurant ( ) Other ( )
No. of Existing Dwelling Units in this building: No. of Accommodation Units in this building:
No/Type of Fireplaces Existinq: Gas Appliances () Gas Logs () Wood/Pellet () Wood Burninq ()
No/Type of Fireplaces Proposed: Gas Appliances () Gas Logs () Wood/Pellet () Wood Burning (NOT ALLOWED)
Is this a conversion from a wood burning fireplace to an EPA Phase II device? Yes () No ()
************************FOR OFFICE USE ONLY***********
F:\cdev\FORMS\PERMITS\Building\mechanica��ermit 11-23-2005.DOC
,
I � , � ��;; � ! I
�,� il
APR � � 2Q0� � u�
11/23/2005 I_
TP'!\A/h� l`lC iIn �C
�
� �` � ` �
Town of Vail Mechanical Codes and Design Criteria
♦ You must obtai� D�sign Review Board (DRB) approval if any of the mechanical work will involve
ANY exterior wbrk. This includes and is not limited to removal and replacement of driveway snow
melt systems. Please contact the Development Review Coordinator at 479-2128 for additional
information.
♦ The Town of Vail has adopted the 2003 International Mechanical Code and the 2003 International
Fuel Gas Code.
♦ All new construction within the Town of Vail is considered to be of unusually tight construction,
thus all combustion air is required to be drawn from outside the structure for mechanical
equipment.
Town of Vail Fireplace Ordinance
In September of 1991, the Vail Town Council adopted an ordinance which restricts te construction and
use of open hearth fireplaces within municipal boundaries. Since that time the ordinance has
undergone numerous changes and revisions, striving for compromise, yet effectiveness in addressing
the air quality issue. Therefore the following criteria has been adopted:
♦ Construction of open hearth wood burning fireplaces is no longer permitted within Town of Vail
municipal boundaries.
♦ Dwelling Units — Each new dwelling unit may contain:
One (1) EPA Phase II certified solid fuel burning device and no more than two (2) gas appliances
(B vent) .
OR
Two (2) gas log fireplaces and no more than two (2) gas appliance fireplaces (B bent).
♦ Restricted Dwelling Units — Each new restricted dwelling unit may contain:
One (1) gas log fireplace and not more than one (1) gas appliance fireplace.
♦ Accommodatiori Units — Each new accommodation unit may contain:
One (1) gas log fireplace or one (1) gas appliance fireplace.
♦ If two or more separate dwelling units or accommodation units are combined to form one larger
unit, the combined unit may retain one woodburning fireplace (if one already exists) and no more
than 2 gas appliance fireplaces, or may convert up to �inro existing fireplaces to gas.
♦ If during the course of a remodel an existing woodburning fireplace is altered or moved, the unit
must then comply with all provisions of the ordinance. That is, the fireplace must be converted to
natural gas or r�placed by an EPA Phase II certified unit.
F:\cdev\FORMS\PERMITS\Building\mechanical�ermit_i1-23-2005.DOC ii/23/2005
TOWN OF VAIL
75 S. FRONTAGE ROAD
VAIL, CO 81657
970-479-2138
DEPARTMENT OF COMMUNITY DEVELOPMENT
NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES
Job Address:
Location.....:
Parcel No...:
Legal Description:
Project No :
MECHANICAL PERMIT
241 E MEADOW DR VAIL
VAIL VILLAGE PARKING STRUCTURE
210108227002
OWNER TOWN OF VAIL
C/O FINANCE DEPT
75 S FRONTAGE RD
VAIL
CO 81657
APPLICANT R& H MECHANICAL LLC
PO BOX 810
EAGLE
CO 81631
License: 184-M
CONTRACTOR R& H MECHANICAL LLC
PO BOX 810
EAGLE
CO 81631
License: 184-M
Desciption: ADD 2 NEW BOILERS
V aluation: 1, 500 , 000. 00
04/20/2006
Permit #:
Status . . . .
Applied . . :
Issued . . .
Expires . ..
M06-0116
ISSUED
04/20/2006
OS/24/2006
11 /20/2006
04/20/2006 Phone: (970) 328-2699
04/20/2006 Phone: (970) 328-2699
Fireplace Information: Restricted: Y lt of Gas Appliances: 0 # of Gas Logs: 0 # of Wood Pellet: 0
***************�*************�*************�*****��***************** FEE SUMMARY *�***********************************************�**********
Mechanical---> $30, 000. 00 Restuarant Plan Review--> $o. 00 Total Calculated Fees--> $37, 503 . o0
> 37, 503 .00 Additional Fees-----------> 37, 503.00)
Plan Check---> $� , 500 . 00 TOTAL FEES-------------- $ Total Permit Fee----------> $o . o0
Investigation-> $ 0. 0 o payments-------------------> $ 0. 0 0
Will Call----> $3 . 00 0. 00
BALANCE DUE-------->
*************�*******************�*****************************�************�*************************************************************�******
Item: 05100 BUILDING DEPARTMENT
05/23/2006 cgunion Action: COND see conditions
Item: 05600 FIRE DEPARTMENT
CONDITION OF APPROVAL
Cond: 12
(BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE.
Cond: 22
(BLDG.): COMBUSTION AIR IS REQUIRED PER CHAPTER 7 OF THE 2003 IMC AND SECTION
304 OF THE 2003 IFGC AS MODIFIED BY TOWN OF VAIL.
Cond: 23
(BLDG.): BOIILER INSTALLATION MUST CONFORM TO MANi7FACTURER'S INSTRUCTIONS AND
CHAPTER 10 OF THE 2003 IMC.
Cond: 25
(BLDG.): GAS APPLIANCES SHALL BE VENTED ACCORDING TO CHAPTER 5 OF THE 2003 IFGC.
Cond: 29
(BLDG.): ACCESS TO MECHANICAL EQUIPMENT MUST COMPLY WITH CHAPTER 3 OF THE 2003
IMC AND CHAPTER 3 OF THE 2003 IFGC..
Cond: 31
(BLDG.): BOILERS SHALL BE MOUNTED ON FLOORS OF NONCOMBUSTIBLE CONST. UNLESS
LISTED FOR MOUNTING ON COMBUSTIBLE FLOORING.
Cond: 32
(BLDG.): PERMIT,PLANS AND CODE ANALYSIS MUST BE POSTED IN MECHANICAL ROOM PRIOR
TO AN INSPECTION REQUEST.
Cond: 30
(BLDG.): BOILER ROOMS SHALL BE EQUIPPPED WITH A FLOOR DR.AIN OR OTHER APPROVED
MEANS FOR DISPOSING OF LIQUID WASTE PER SECTION 1004.6.
Cond: CON0008081
CONDITIONS OF APPROVAL:
1) GAS VENT TERMINATION SHALL COMPLY WITH IFGC 503.6.6
2) DECORATIVE SHROUDS SHALL NOT BE INSTALLED AT VENT TERMINATIONS UNLESS LISTED
PER IFGC 503.6.6.1
3) BOILER VENT OFFSET SHALL COMPLY WITH IFGC 503.6.4
4) EQUIPMENT HAVING AN IGNITION SOURCE SHALL BE ELEVATED MINIMUM 18" ABOVE THE
GARAGE FLOOR PER IFGC 305.3
5) EF-1 COMBUSTION AIR FAN SHALL BE INTERLOCKED WITH APPLIANCES PER IFGC 304.9.2
*�*�******************�**************************�*****�***************************�****�***************�*************************�*�***�********
DECLARATIONS
I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot
plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply
with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design
review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto.
PNQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS I,N�AD nN��BY TELEPHONE AT 479-2149 OR AT OUR OFFICE FROM 8:00 AM - 4
n
SIGNATURE OF OWNER OR CONTRACTOR FOR HIMSELF AND OWNEF
APPLICATION WILL NOT BE ACCEPTED IF INCOMPLETE OR UNSIGNE 4 -��
TOV Project #:
Building Permit #: -
�• , � �� Mechanical Permit #: -� a �i
• � 970-479-2149 Ins ections
������
� � P )
75 S. Frontage Rd.
Vail, Colorado 81657
E-Mail Address:
Contractor Sig
MECHANICAL: $
TOWN OF VAIL MECHANICAL PERMIT APPLICATION
Permit will not be accepted without the following:
Provide Mechanical Room Layout drawn to scale to include:
❑ Mechanical Room Dimensions
❑ Combustion Air Duct Size and Location
❑ Flue, Vent and Gas Line Size and Location
❑ Heat Loss Calcs.
❑ Equipment Cut/Spec Sheets
CONTRACTOR INFORMATION
Town of Vail Reg. No.: Contact Person and Phone #'s:
�- � � �f �'1 � .� r� G � 970 � �-sz 7 �
Fax#:
VALUATION FOR MECHANICAL PERMIT
� ,r�, �oC� , '�-'r
- 3z�-a
bor & Materials
************************FOR OFFICE USE ONLY*********�'�'i`(��`���a�:�'���*i'�',T�`
APR 19 2006
F:\cdev\FORMS\PERMTfS\Building\mechanical�ermit 11-23-2005.DOC � �'��� ��/��
TOWN OF VAIL FIRE DEPARTMENT
75 S. FRONTAGE ROAD
VAIL, CO 81657
970-479-2135
VAIL FIRE DEPARTMENT
NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES
SPRINKLER PERMIT Permit #: F06-0039
'�i�-oo� �
Job Address: 241 E MEADOW DR VAIL Status ...: ISSUED
Location.....: VAIL VILLAGE PARKING STRUCTURE MECHANICAApplied ..:06/30/2006
Parcel No...: 210108227002 Issued ... 07/21/2006
Project No : ���56� - d ( `� `� � Expires . .:
OWNER TOWN OF VAIL
C/O FINANCE DEPT
75 S FRONTAGE RD
06/30/2006
VAIL
CO 81657
APPLICANT WESTERN STATES FIRE PROTECTI06/30/2006 Phone: 303-792-0022
7026 SOUTH TUCSON WAY
ENGLEWOOD
CO 80112
License: 338-S
CONTR.ACTOR WESTERN STATES FIRE PROTECTI06/30/2006
7026 SOUTH TUCSON WAY
ENGLEWOOD
CO 80112
License: 338-5
Phone: 303-792-0022
Desciption: CONSTRUCTION OF E. MEADOW BOILER ROOM AND SNOWMELT-ADD AND
RELOCATE AS REQUIRED IN MECHANICAL ROOM
Valuation: $4,575.00
*************��***************************************************** FEE SUMMARY ************************�****************�****�**********�**
Mechanical---> $0. 00 Restuarant Plan Review--> $0. 00 Tota] Calculated Fees---> $544 .44
Plan Check---> $350.00 DRB Fee---------------------> $0. 0o Additional Fees-----------> ($544.44)
Investigation-> $o. oo TOTAL FEES--------------> $544.44 Total Pernut Fee----------> $o. o0
W ill Call-----> $ o- 0 0 Payments-------------------> $ o. 0 0
BALANCE DUE---------> $ 0. 0 0
++***********�*******+****++*******�******************************+********�*************************************�*******************�**********�
Item: 05100 BUILDING DEPARTMENT
Item: 05600 FIRE DEPARTMENT
07/19/2006 mvaughan Action: AP
CONDITION OF APPROVAL
Cond: 12
(BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE.
*�*********�*******�*�****************�**************�***�*******************�***�**********+*********************************************�***��*
DECLARATIONS
I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot
plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply
with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design
review approved, International Building and Residential Codes and other ordinances of the Town applicable, thereto.
REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 479-2135
FROM 8:00 AM - 5 PM.
/1�. ��� �--
A�PLfGATf0�1t WILL N�T BE ACCEPTED �F tNCOMPE.E'FE O�R��� �G� �! ,��(SiL
�O
-'��, . ' �
` B�;lding Permit #:
�� SPrink�er Permit #: —
• g70-d79-2135 (tnspections)
-�
'��'N�Y.,� '
75 S. Frontage Rd. �
Vail, Colorado
81657
.--
,�-�;-,.---r-; ,; .
�� lt , �, ;: �`'� 'I
D
JuN 2 g 2oas
TOWN Or WAI
TOWN OF VAIL FIRE SPRINKLER PERM�T APP�ICATIC)N
F�re gpri�kler shop drawings are required at time of permit submittal and
must inciude the foilowing. Permit apR�i�ation witl nat be accepted
- � this inforrnation:
�� lorado Registered Engineer's stamp or N.I.C.E.T. Level lll (min) stamp.
• E i ment cut sheets ofi materials.
• H ulic ca(cufations.
• AI ,te of Colorado Plan Registration form.
. PIa� must t�e submitted by a Registered Fire Protection Contractor.
INFORMATION
Fire Sprinkler Contractor. Trnnrn of Vail Reg. No.: Contact ancf Phone #'s:
Western States 338-S A1 B�uch 303-549-9232
E-Mail Address: al.k�ruch sf ,us
Contractor Signature: !
COMPLETE VALUATIONS FOR ALARM PERMIT (Labor 8� Materials)
Fire Sprinkt 575.Q0
.�.�...�.�.,
FOR OFFICE USE NLY**�*****'`"*'"`��""""***"****'`**"******
*****************************�***:***�* ---,
ees:
APPLICATION WILL NOT BE ACCEPTED IF INCOMPLETE OR UNSIGN �! _�(��
Project #: �� +`
..� �
�,��; Building Permit #: '
Sprinkler Permit #: �
"�' 970-479-2135 (Inspections)
�
����� �x �'
75 S. Frontage Rd. �
Vail, Colorado
81657
� : � � � -f
��_l !� I �+I i
D
JUN 2 9 2006
TOWN O� i�Ai
TOWN OF VAiL FIRE SPRINKLER PERMIT APPLICATION
Fire Sprinkler shop drawings are required at time of permit submittat and
must include the foliowing. Permit application will not be accepted
�nr t this information:
� orado Registered Engineer's stamp or N.I.C.E.T. Level III (min) stamp.
. E � ment cut sheets of materials.
. H ulic catcuiations.
• A te of Colorado Plan Registration form.
• P must be su�nitted by a Registered Fire Protection Contractor.
INFORMATION
Fire Sprinkler Contractor. Town of Vail Reg. No._ Contact and Phone #'s:
Western States 338-S A1 Bruch 303-549-9232
E-Mail Address: al.bruc sf .us �
Contractor Signature: �
COMPLETE VAlUAT10NS FOR ALARM PERMIT (Labor 8� Materials)
Fire Sprinkler. $ 4,575.00
Contact Eagle Coun#yAssessors �ce a# 970-328-8640 or visit .°, .�� � t�-4;� ��3.'r;�, ���=��}1 for Parcel �
Parcel #
Job Name: Job Address:
VAIL PARKING GARAGE 242 E. MEADOW DRIVE
Legal Description Lot: Block: Filing: Subdivision:
Owners Name: Address: Phone:
TOWN OF VAlL
Engineer: Address: Phone:
Detailed Location of work: (i.e_, floor, unit #, bldg. �
WEST MECHANtCA� ROOM
Detailed description of work: ' �'
Add & relocate as re uired for new rraechanical room.
Work Class: New {) Addition {�) Remodel (�) Repair {Q) Retrafrt (�) Other (❑)
Type of Bldg.: Single-family (�) Two-family (�) Multi-famity (�) Commercial (�) Restaurant (�) Other (�)
No. of F�cisting Dwelling Units in this building: No. of Accommodation Units in this building:
Does a Fire Alarm Exist: Yes (�) No {0) Does a Fire Sprinkler System Exist: Yes (�) No (�)
*�******�***************************�:*FOR OFFICE USE NLY�**:***�******�**********************
�
0
04-12-2007
4:26 qm
AIPID Information
Activity: M06-0116
Const Type:
Owner: TOW N Of
Applicant: R& H ME
Contractor: R & H ME
Description: ADD 2 NE
Comment: CONDITI(
Comment:
:al
�9�
Inspection Request Re
vail �_n _ (:itv O
ng
Requested Inspect Date: Friday, April 13, 2007
Inspection Area: CG
Site Address: VAI VILLA E PARKING STRUCTURE
Type: B-MECH
Occupancy:
LLC
Sub Type: ACOM
Use:
Phone: (970) 328-2699
Phone: (970) 328-2699
���^ �. �r�.s�' C
Page 29
Status: ISSUED
Insp Area: CG
F APPROVAL:
=RMINATION SHALL COMPLY WITH IFGC 503.6.6
: SHROUDS SHALL NOT BE INSTALLED AT VENT TERMINATIONS UNLESS LISTED
�.6.1
f OFFSET SHALL COMPLY WITH IFGC 503.6.4
HAVING AN IGNITION SOURCE SHALL BE ELEVATED MINIMUM 18" ABOVE THE
R PER IFGC 305.3
STION AIR FAN SHALL BE INTERLOCKED WITH APPLIANCES PER IFGC 304.9.2 -
TOLD TO CONFIRM THE MOTORS USED WITH VFD DRIVES ARE RATED FUR SUCH
Requested Inspection(s)
Item: 390 MECH-Final
Requestor: R& H MECHANICAL LLC
Comments: final on boilers
Assigned To: GDENCKLA Time Ex
Action: P�
Comment: 2_PIPE NEUTRALIZER TO FLOOF2 DRAIN.
N�
C
IPIPE f
ER IN;
�LVAN
�DE IN
Requeste Phone: (970) 328-2699
Entered By: DGOLDEN K
FOR HYDRONIC PIPING IN BOILER ROOM.
t TO PROVIDE SUPPORT.
�N REQD. �
L ON VENT TO STAINLESS.
�E REVERSE FALL. ; .�; - � _� � �
3AS VENT TERMINATION. .,;y
�x
> -',.,; � ' _ ,.
i .
� �, s
.. r.._ ,�` ( _ �
{
� �•....
;. ' ;
� a
4 r
�,
��,
Inspection Historv
Item: 200 MECH-Roug h "* Approved *" ;'
11/08/06- Inspector: JEC Action: DN DENIED
Comment: Boiler flue not installed to mfg's installation instructions. Mfg calts for MIN 1/4 inch per foot pi�ch
back to boiler: DO NOT have 1/4 inch per foot. Flue distance OK. No control for interlock of ;�`
combustion air. IMC 706.1 & IFGC 304.9 & 304.9.2 Need air switch on combustion air for int�rlock
not just closed contacts from VFD. Need to�prove control of combustion air through VFD wil
supply enough combustion air. Approx. 8,4Q0,000 BTU input from both boilers. N-eed appro 3400
cfm with botfi boilers on at same time. No pro�raminq to start & control combustion air at this
time. Must have temp flue caps until building is instafied.
11/09/06 Inspector: JEC Action: NR NOT READY FOR INSPECTION
Comment: Still working on controls
11/13/06 Ins ector: JRM Action: AP APPROVED
Comment: CORREC�T ONS COMPLETE�D.
OK TO FIRE UP AND PROGRAM
Item: 310 MECH-Heating.
Item: 315 PLMB-Gas Piping "* Approved ""
11/08/06 lnspector: shahn Action: AP APPROVED
Comment: inspected gas piping for 2 new boilers. 6# Air test.
e�Item: 320 MECH-Exhaust Hoods
Item: 330 MECH-Supply Air
� Item: 340 MECH-Misc.
Item: 390 MECH-Final
11/13/06 Ins pector: GCD Action: CR CORRECTION REQUIRED
Comment: 1.LEAK AT CONDENSATE TRAP.
REPT131 Run Id: 6568
B06-0089: Entries for Item:90 - BLDG-Final 12:10 10/11/2012
Action Comments By Date Unique_
Ke
DN attached permits require finals prior to bldg JRM 11/07/2006 A000095
final request. 376
left messa e
AP JRM 01/31/2012 A000148
807
Total Rows: 2
Page 1
F06-0039: Entries for Item:538 - FIRE-FINAL C/O 12:11 10/11/2012
Action Comments By Date Unique_
Ke
AP Fire sprinkler portion OK. mcgee 11/13/2006 A000095
610
Waitin for info on alarm monitorin .
Total Rows: 1
Page 1