Loading...
HomeMy WebLinkAboutPRJ08-0197 B08-0261NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES �,_,��'�� j. TOWNOFVAII, ' Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657 f�r< <�i�Ut�%��+� ���� p. 970.479.2139, f. 970.4792452, inpsections 970.4792149 � �J(�,�� ��I j(�I 1� ADD/ALT MF BUILD PERMIT Job Address: 145 N FRONTAGE RD VAIL Location......: MIDDLE CREEK APARTMENTS Parcel No....: 210106409001 CONTRACTOR RILO ELECTRIC & COMMUNICATIO 10/21/2008 1822 SKYWAY DRIVE, UNIT 0 LONGMONT COLORADO 80504 License: 368-A APPLICANT ADVANCED WIRELESS SOLUTIONS 08/04/2008 12390 W. 75TH AVENUE ARVADA COLORADO 80005 License: 921-B OWNER TOWN OF VAIL 08/04/2008 75 S FRONTAGE RD W VAI L CO 81657 Phone:(303)774-2029 Phone:(303)277-0388 Description: ADD EXTERNAL EQUIP SHELTER AND ANTENNAS TO ELEVATOR SHAFT Occupancy: U Type Construction:VB Permit #: Project #: Status . . : Applied . . : Issued . .. : Expires . ..: B08-0261 PRJ08-0197 ISSUED 08/04/2008 10/21I2008 04/14/2009 Valuation: $50,000.00 Total Sq Ft Added: 0 ...,, ........................,..>.....,...�,...,........��.�.....,�....,,.,.....,..,, FEE SUMMARY ..<......���...,......,.,........���.�.�...,...,.....�.,..,.�.....,,...,..,,.,,. Building Permit Fee------> $643.75 Will Cal Fee---------------------> $4.00 Total Calculated Fees-------------> $1,866.19 Plan Check--------------------> $418.44 Use Tax Fee---------------------> $800.00 Additional Fees-----------------------> $0.00 Add'I Plan Check Hours-> $0.00 Restuarant Plan Review-----> $0.00 TOTAL PERMIT FEES--------------> $1,866.19 Investigation-----------------> $0.00 Recreation Fee-----------------> $0.00 Payments-------------------------------> $1,866.19 Total Calculated Fees--------> $1,866.19 BALANCE DUE------------------------> $0.00 ..,......,, ........................,........,..........,,...���,,,,..���,.....,.......�........�.......,..,..,.,,...,,..��,,,...,..,,......,�,�.......,.......,..,,,.,.............,......,�.,,.,. DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8:00 AM - 4:00 PM. j O .�2 0 �� Signature of Owner or C ntractor Dat uJ r', �(`� Print Name bid_alt_construction_perm it_041908 ,. �,.�....,...,.,.....�.....,,�.....� ................�...,,.�...�....,�..........�........,.�.............,.........«.........�,...,....,.........,.........,...��..,..,.....,�,..,....., APPROVALS Permit #: 608-0261 as of 10-22-2008 Status: ISSUED ,........,�......,..�....,,.�...,......,.�� ...........................�,,.�.,,,,,�,�.....,,,..,...�........,,.,.�...............��,�..���,..,,�.�,.......,,,,.......�..,..,....,,,....,.. Item: 05100 BUILDING DEPARTMENT 08/19/2008 MH Action: CR F:\cdev\CHRIS\PERMIT.COMMENTS\B08-0261 \608-0261. DOC 09/26/2008 cgunion Action: CR second comment letter sent F:\cdev\CHRIS\PERMIT.COMMENTS\B08-0261 \B08-0261.secondcheckDOC. DOC 10/03/2008 cgunion Action: COND FIRE BARRIER WALL ON SOUTH AND EAST SIDES FACING THE ADJACENT BUILDING MUST EXTEND TO THE FOUNDATION PER IBC 706 Item: 05400 PLANNING DEPARTMENT 08/07/2008 npeterson Action: COND Approved plans date stamped Aug 1, 2008. SEE CONDITIONS SCREEN Item: 05600 FIRE DEPARTMENT 09/08/2008 McGee Action: DN Plans do not show fire protection system as required for this project. 10/13/2008 cgunion Action: AP APPROVED PER VERBAL FROM MCGEE. DRY CHEMICAL SYSTEM WILL BE USED PER LETTER IN FILE Item: 05500 PUBLIC WORKS 08/20/2008 cdelles Action: AP ........................................................... � �..,..,............... �...,...,..,.... �,,.,...,.,. �.....,..... �.,..,.........,,,.. � �.........,...,..,...........,..,....... See the Conditions section of this Document for any that may apply. b Id_alt_construction_perm it_041908 ,.. ............................................�.......�.,,....,...�..�.......................,.,...��...�...�„>..,...,.,,...,........�.........,.......,.�.,......,.....�....,.,,,.... CONDITIONS OF APPROVAL Permit#: B08-0261 as of 10-22-2008 Status: ISSUED ...,�.....,....> ...................>..,,....,...��...�..�...,.x............,.,........,,.......,,....�..,..,....................,�.............,,,.....�......,............,,.....,.�, Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. Entry: 08/07/2008 By: npeterso Action: AP DRB conditions: 1. The Applicant shall paint the proposed antennas to match the existing Middle Creek tower structure within 5 days of antenna installation. 2. The Applicant shall construct the ground equipment shelter with the same materials and design as the existing Middle Creek tower structure within 5 days of antenna installation. 3. Design Review Board approval of the application (DRB 08-0228) becomes effective on July 24, 2008, the same date as Ordinance No. 12, Series of 2008, an ordinance amending Sections 12-9C, General Use District and 12-16, Conditional Use Permit, Vail Town Code to allow certain conditional uses as permitted uses. Cond: 14 (BLDG.): ALL PENETRATIONS IN WALLS, CEILINGS, AND FLOORS TO BE SEALED WITH AN APPROVED FIRE MATERIAL. Cond: 1 (FIRE): FIRE DEPARTMENT APPROVAL IS REQUIRED BEFORE ANY WORK CAN BE STARTED. Cond: 40 (BLDG): (MFR/COMM) FIRE ALARM REQUIRED PER NFPA 72. Cond: CON0010358 SOUTH AND EAST FIRE BARRIER WALLS ADJACENT TO THE EXISTING BUILDING SHALL EXTEND TO THE FOUNATION PER IBC 706 bld_alt_construction_perm it_041908 Transmittal Form Revision Submittals: 1. "Field SeY' of approved plans MUST accompany revisions 2. No further inspections will be performed until the revisions are approved & the permit is re-issued. 3. Fees for reviewing revisions are $55.00 per hour (2 hour minimum), and are due upon issuance. Permit #(s) information applies to: Attention: (� c� �~- Q�Z b � C I-�lt i S Project Address: l`� S�i , C�'^�iA�z.d n D Contact Information .� w�S 1 ( ) Revisions (�Response to Correction Letter G v� ��� �ttached copy of correction letter ( ) Deferred Submittal ( ) Other Company: r� ;� �� �t�! ��N�IInVnt E <�� i/�^..1� '11 CompanyPh:�7Q,i�s� L�1�i(� Fax: ��, �����,ID�I� '' Contact Name: �'�1 1�� � S�� � 2�^='"J Contact Ph: `'� �� ��� S� +Z�t�1 �, Cell: ' E-Mail: :'1/1 KS 1-I �j R 1..� �� :�- � G MAc'1 L.�.t%Ni Town of Vail Contractor Registration No: X�`--'''�� � �__�---"""""__ Signature (required) __ �... Revised ADDITIONAL Valuations (Labor 8� Materials) ', (DO NOT include original valuation) ; Building $ Plumbing $ Electrical $ Mechanical $ Fire Sprinkler/Alarm $ Total $ Description / List of Changes: (Use additional sheet if necessary) Date Received: r C� C� (� r� 1� �� D �, � .. _�� �,4 � TO�i� C1� `��I�. � _________.�-_ ********************************+***********************************+*******************+*** TOWN OF VAIL, COLORADO Statement *************+***********+***+*************+*********************++*****+************+****** Statement Number: R080001294 Amount: $418.44 08/04/200811:39 AM Payment Method: Check Init: JLE Notation: 1334 SITE DEVELOPMENT SERVICES LLC ------------------------------------------------------------------- Permit No: BO8-0261 Type: ADD/ALT MF BUILD PERMIT Parcel No: 2101-064-0900-1 Site Address: 145 N FRONTAGE RD VAIL Location: MIDDLE CREEK APARTMENTS Total Fees: $1,866.19 This Payment: $418.44 Total ALL Pmts: $418.44 Balance: $1,447.75 *******+***************+*****************************************************+**+*********** ACCOUNT ITEM LIST: Account Code -------------------- PF 00100003112300 Description Current Pmts ------------------------------ ------------ PLAN CHECK FEES 418.44 -------------------------------------------------------------------- NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES . , 10WNOF VAII. ' Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657 p. 970.4792139, f. 970.479.2452, inpsections 970.479.2149 ADD/ALT MF BUILD PERMIT Permit #: B08-0261 Job Add�ess: 145 N FRONTAGE RD VAIL Location......: MIDDLE CREEK APARTMENTS Parcel No....: 210106409001 OWNER TOWN OF VAIL 08/04/2008 75 S FRONTAGE RD W VAIL CO 81657 APPLICANT ADVANCED WIRELESS SOLUTIONS 08/04/2008 Phone: (303) 277-0388 12390 W. 75TH AVENUE ARVADA COLORADO 80005 License: 921-B CONTRACTOR ADVANCED WIRELESS SOLUTIONS 08/04/2008 12390 W. 75TH AVENUE ARVADA COLORADO 80005 License: 921-B Phone:(303)277-0388 Description: ADD EXTERNAL EQUIP SHELTER AND ANTENNAS TO ELEVATOR SHAFT Occupancy: U Type Construction:V6 Project #: Status . . : Applied . . : issued . .. . Expires . ..: PRJ08-0197 ISSUED 08/04/2008 10/16/2008 04/14/2009 Valuation: $50,000.00 Total Sq Ft Added: 0 ..x,.,.,.,..�..,.,,, ......................,,�..............,,,,..........�.....�..� FEE SUMMARY .,.,,,......,....,,.................,,,,......,........,,..........,,,..,......,....,. Building Permit Fee------> $643.75 Will Cal Fee---------------------> $4.00 Total Calculated Fees-------------> $1,866.19 Plan Check--------------------> $418.44 Use Tax Fee---------------------> $800.00 Additional Fees-----------------------> $0.00 Add'I Plan Check Hours-> $0.00 Restuarant Plan Review-----> $0.00 TOTAL PERMIT FEES--------------> $1,866.19 Investigation-----------------> $0.00 Recreation Fee-----------------> $0.00 Payments-------------------------------> $1,866.19 Total Calculated Fees--------> $1,866.19 BALANCE DUE------------------------> $0.00 •�rt �rt�/e'Rl4wf Y�#xl4rtrtf f xflertrttrwf f�f�f�f ie/efrxfrf /�#texlfrtrt�ke�kl� #'rtYex+f�li�rt/�irirrtiltrf*kl4�Rfr�.F!!##f YrY'4f iF4i�f rt*x�lLfirM'�kfr+R#f�lEwhkRf intYrYr*x�kfY'YrwrtRi`4Y�aiiliri(ieY(ii�!#wk�Fw�Rl41r wYrx4RRe�kh*#*YrYrf f irRkwYr#4irhw�kw� � i"k�.F*4� DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE DE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8:00 AM - 4• �� �� � � Q Signature of Owner or t ctor Date /�'-� �, c� lyiti ,rv . Print Name bld_alt_construction_perm it_041908 ,..,...< ...................................x��....,.,.�......,........,........................,...,...........,...�.,....,......,.....,...............,.,....,..,,..........,....... APPROVALS Permit #: 608-0261 as of 10-16-2008 Status: ISSUED • rt� #rt �kx41`rt/Yrtxi(ilYrYrYr�Rlrlf i`i`f w�f4lrirYrYefrtrtlrYrww�fRRfrwY`�k44#fhYrx#4ir4w+kf i(kMRfiff#�k/w�Rf 4f/rtYeR4rtfrka44witww�F1`4Yewwt�f�AfrtYrw�krtrtf 1rwwY�4f�Rkf'wir4R#fr*�!i(RRYr*+frttrYrYriRlnFYrlrYeflAYrYrte44f fYr1'1�4lfYete4i`f trRRfY`rtYrRfLi1'Yrhwfrt Item: 05100 BUILDING DEPARTMENT 08/19/2008 MH Action: CR F:\cdev\CHRIS\PERMIT.COMMENTS\B08-0261 \608-0261. DOC 09/26/2008 cgunion Action: CR second comment letter sent F:\cdev\CHRIS\PERMIT.COMMENTS\608-0261 \B08-0261.secondcheckDOC.DOC 10/03/2008 cgunion Action: COND FIRE BARRIER WALL ON SOUTH AND EAST SIDES FACING THE ADJACENT BUILDING MUST EXTEND TO THE FOUNDATION PER IBC 706 Item: 05400 PLANNING DEPARTMENT 08/07/2008 npeterson Action: COND Approved plans date stamped Aug 1, 2008. SEE CONDITIONS SCREEN Item: 05600 FIRE DEPARTMENT 09/08/2008 McGee Action: DN Plans do not show fire protection system as required for this project. 10/13/2008 cgunion Action: AP APPROVED PER VERBAL FROM MCGEE. DRY CHEMICAL SYSTEM WILL BE USED PER LETTER IN FILE Item: 05500 PUBLIC WORKS 08/20/2008 cdelles Action: AP ,.....� .................................x..,.,........,...,,.......,,,�.....,................x.,...,.,..,....,.,....,..........�.x.,......,..........�.�.........,.�,.......,......... See the Conditions section of this Document for any that may apply. b Id_a It_co n st ru ct i o n_pe rm it_041908 +a�+w#��ww���w�+�kkw*ff�fwRf��fkR�MwkxxflfixR�fwe��kf�xf�w/�����fxlf���f�#w*��Mww+�ww##1ff��kfw�klxwN>fYwwwRk#kf�*##wwf��ww*�#ww+�fwwkf�fff�#w����fx�xwwf#�w�f��wi��#+i��wwR��ww�+Nwi CONDITIONS OF APPROVAL Permit #: 608-0261 as of 10-16-2008 Status: ISSUED .............................�,........,......�.,,,..,,...�.............,,....,�..,..,........,....,,.,,,,..........,,...�,.........:,......,........,..,.>..,.......,........,....... Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. Entry: 08/07/2008 By: npeterso Action: AP DRB conditions: 1. The Applicant shall paint the proposed antennas to match the existing Middle Creek tower structure within 5 days of antenna installation. 2. The Applicant shall construct the ground equipment shelter with the same materials and design as the existing Middle Creek tower structure within 5 days of antenna instatlation. 3. Design Review Board approval of the application (DRB 08-0228) becomes effective on July 24, 2008, the same date as Ordinance No. 12, Series of 2008, an ordinance amending Sections 12-9C, Generai Use District and 12-16, Conditional Use Permit, Vail Town Code to allow certain conditional uses as permitted uses. Cond: 14 (BLDG.): ALL PENETRATIONS IN WALLS, CEILINGS, AND FLOORS TO BE SEALED WITH AN APPROVED FIRE MATERIAL. Cond: 1 (FIRE): FIRE DEPARTMENT APPROVAL IS REQUIRED BEFORE ANY WORK CAN BE STARTED. Cond: 40 (BLDG): (MFR/COMM) FIRE ALARM REQUIRED PER NFPA 72. Cond: CON0010358 SOUTH AND EAST FIRE BARRIER WALLS ADJACENT TO THE EXISTING BUILDING SHALL EXTEND TO THE FOUNATION PER IBC 706 b I d_a It_co n st ru ct i o n_pe rm it_041908 **********************************�***++***********************+**************************** TOWN OF VAIL, COLORADO Statement **************************+**************************************�************************** Statement Number: R080001964 Amount: $1,447.75 10/16/200811:39 AM Payment Method: Check Init: DDG Notation: Rilo Electric & Communications 22482 ----------------------------------------------------------------------------- Permit No: B08-0261 Type: ADD/ALT MF BUILD PERMIT Parcel No: 2101-064-0900-1 Site Address: 145 N FRONTAGE RD VAIL Location: MIDDLE CREEK APARTMENTS Total Fees: $1,866.19 This Payment: $1,447.75 Total ALL Pmts: $1,866.19 Balance: $0.00 **********+*******************+*****************************�************+****************** ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------------- ------------------------------ ------------ BP 00100003111100 BUILDING PERMIT FEES 643.75 UT 11000003106000 USE TAX 4°s 800.00 WC 00100003112800 WILL CALL INSPECTION FEE 4.00 ----------------------------------------------------------------------------- � u � APPLICATION WILL NOT BE ACCEPTED IF INCOMPLETE OR UNSIGNED �a,p��„Q � q Project #: ' .��v v 1 "i""owrr of Vaii Buildin Permit #: a � a- � �« � f�'� � s�u���� ��;�`���������i��� ����� t � ��� ����Y 75 S. Frontage Rd. Vail, Colorado 81657 TOWN OF VAIL BUILDING PERMIT APPLICATION Separate Permits are required for electrical, plumbing, mechanical, etc.! CONTRACTOR INFORMATION eneral �#�actor: , Town of Vail Reg. No.: Contact Person and Phone #'s: �to' 'r�.t, 1 �3, � '„� '" ��'s �' �._�,'1°(:G, . Email address: � � �:� �� ��`� ��" .S:`�► c d � x #: ��'�cs' _ '?,�-� �.��y Contractor Sign r � . CO E VALUATIONS FOR BUILDiNG PERMIT Labor & Materials BUILDING: $ ELECTRICAL: $ OTHER: $ �v PLUMBING: $ MECHANICAL: $ -� TOTAL: $ �(� ��� Fipr Parcel # Contact Ea le Counf Assessors Office at 970-328-8640 or visif www.ea le-count .com �,-� ,� -� � -�, .� r.��,�,.e��s Z%S� ��i ��`�# c.' - � � �'��T �." %� ! ��...5: t � �� � Z ��' �" (�'�,y � U� C'�.`� � ?V 1 �Mk.St-#ii�w.��- C,N Job Name: ,. .- � � Job Address: � ` . +� �- � C. l� � �` N11 � r� L�. �.. i"�� �. t� :'� ti I ' � l `% � !�,l , ryL�:� � ( � � �r i2� s Legal Description Lot: Block: Filing: Subdivision: Owners Name:v�ll. �"��t�� �"t'i�+�K Address: C . ` �:(:,}�� �L� � Phone: �`:-� �.., - �r� � �. Architect/Designer: Address: Phone: +� �; ;u � i t' i� '�i r 3" �� ��u ��„J::� i' Engineer: Address: ;];v„��c i�it CO ��t �+y Y�� � Phone: ��`at,' , t�y 4 S�r Z S •"v�► i Detailed description of work: � r� t� �� L k��,fZ+c: � c�� .'' �. �% `� s�� %(: tt A'�' } � �'�i.'� � ,t.� j= T �%iC" °� �J t,. , (=��c Z (.L'�:3'rc �tft�^a'�..� s� J�J ��?U,� A.� 'i"�(3 C:�X '?L-:/2;vr�. t LEU' �1 iC ,'� �5'f Work Class: New ( ) Addition (1�`) Remodel ( ) Repair ( ) Demo ( ) Other ( ) Work Type: Interior () Exterior (�j Both () Does an EHU exist at this location: Yes () No () Type of Bldg.: Single-family ( ) Two-family ( ) Multi-family �) Commercial ( ) Restaurant ( ) Other ( ) No. of Existing Dwelling Units in this building: No. of Accommodation Units in this building: No/T e of Fire laces Existin : Gas A liances Gas Lo s Wood/Pellet Wood Burnin No/T e of Fire laces Pro osed: Gas A fiances Gas Lo s Wood/Pellet Wood Burnin NOT ALLOWED Does a Fire Alarm Exist: Yes () No () Does a Fire Sprinkler System Exist: Yes () No () C_, (_...... _ _ ��; FOR OFFICE USE ONLY�''`*�` - � ' � `- ° h.' SS �z P .�. 3 � �� _a��e Re��a�ed �� � AUG . �(�U� '' !.l �Received��By .. . '� �,�.�� ' � _ �� �' `P �� TOV1/IV �� '�/.�I,� '.. �}.� � _ . F:\cdev\FORMS\Permits�Building\building�ermit_4-17-2007.DOC Page 1 of 7 �• NC� I"E: THIS PERMIT MUST BE POSTED ON JOBS/TE AT ALL TIMES : �ow�oFUnQ. � Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657 p. 970.479.2139 f. 970.479.2452 inspections 970.479.2149 ELECTRICAL PERMIT Permit #: E08-0257 I_\►�iI � Job Address: Location.....: Parcel No...: 145 N FRONTAGE RD VAIL 210106409001 OWNER TOWN OF VAIL 10/22/2008 75 S FRONTAGE RD W VAIL CO 81657 APPLICANT TREVOSE ELECTRIC INC. 1655 AVALON AVENUE LAFAYETfE COLORADO 80026 License: 428-E CONTRACTOR TREVOSE ELECTRIC INC. 1655 AVALON AVENUE LAFAYETTE COLORADO 80026 License: 428-E 10/22/2008 Phone: (303) 591-0584 10/22/2008 Phone: (303) 591-0584 Project #: Desciption: INSTALL THREE PANEL ANTENNAS TO MIDDLE CREEK HOUSING- INSTALL 200A SERVICE/METER AND WIRE A/C POWER TO 2 CRICKET CABINETS Valuation: $3,800.00 Square feet: 100 Status . . . : Applied . . : Issued . . . Expires . .: ��� ���� PRJ08-0197 APPROVED 10/22/2008 .....��......�..«��..��.�.,,�..,,.,,**,,,,**«*«*****«***..*****«.**.*«*,,. �.**,..�.�*,..�.,.*�.,.�.�,.�.�.,.,�,.�«��.,.,,��.�«�...��,,,,�.,,�,...,.�„�.�.,,,««�.,«�„ Electrical Permit Fee---------> Investigation Fee--------------> Will Call Fee--------------------> FEE SUMMARY $51.75 Total Calculated Fees--> $55.75 $0.00 Additional Fees----------> $0.00 $4.00 Use Tax Fee-------------------> $0.00 TOTAL PERMIT FEE---> $55.75 Total Calculated Fees-------> $55.75 Payments-----------------> $55.75 BALANCE DUE----------> $0.00 ..�.,.,..�.�.,,..�...�«�.,,,�,.**««„*«*«„*«*,,,..,*.,,.,....,..�.�,�..,..,..���.�.��„�,.�«*„*«****«„*.*«*«„*�„*«�«.«*«*««*«**««**«***.,*.,*„*.,*.,*,,.,***.,***.*.,,.,***.,*..**...*.*.,,*,.,,,,,, APPROVALS Item: 06000 ELECTRICAL DEPARTMENT 10/22/2008 RLF Action: AP Item: 05600 FIRE DEPARTMENT *.,,,.�..,�,�»,�,,.�.�..,�,..�.�„�«�„��«�«*«*«�„«�«*«**«.,*.,.,.*.,*.,.,**.,**.,«***.*.,**.,****«*.,.**.,...,,*«.,.,.,.,�„«.�„�.�.�«�,.�.,,,�«���«�«**«**«***«,,,.**.,.,«*,.,,**...*.*.,,,,,.�,..,.., CONDITIONS OF APPROVAL Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. ...�..,.,...,,,,,...�,�,....,�....�,....,�.,,��.�.�.«,«,«,.,.««�«��*«�«,..�«,«�*..,,,.«���««�..«�««,.�*,,,.«***.,,,�..«.�.��.,.���.�„�,,.,,�„«�««�«.�*.«�.«***.***.**.,,.,,,,,�,...,..,�.��,.,,,,., DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL B OFFICE �OM �:00 AM - 4 P� � �� � . V (/' y Siqnatu of Ow or Contractor elec_prm_041908 MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR ��" �Z " C��3 Date *******************************************************************************************� TOWN OF VAIL, COLORADO ' Statement ****+************++++******************+**************************************************** Statement Number: R080002013 Amount: $55.75 10/22/200802:40 PM Payment Method:Credit Crd Init: JLE Notation: DAVID J PAPPERT TREVOSE ELECTRIC INC 001036 ----------------------------------------------------------------------------- Permit No: Parcel No: Site Address: Location: E08-0257 Type: ELECTRICAL PERMIT 2101-064-0900-1 145 N FRONTAGE RD VAIL Total Fees: $55.75 This Payment: $55.75 Total ALL Pmts: $55.75 Balance: $0.00 ***********+***************************************+**+***********************************+* ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------------- ------------------------------ ------------ EP 00100003111100 ELECTRICAL PERMIT FEES 51.75 WC 00100003112800 WILL CALL INSPECTION FEE 4.00 1 �� �. � � �� � �� �, li _����; � " ELECTRICAL PERMIT APPLICATION Project Address ly a � °��C�� Y't�e� , Contractor Information � c l� Company: � t'c: � o�f� \�'.•C�\e� C.< �,t'1 L• Company Address: �6�J i�v�d� I'��i� - City: �C� State: �' Zip: ��_ Contact Name: �0��`� �Q171G�� Contact Ph: �03 S�t-- OS$`{ Cell: 3��3 ��` �5�� E-Mail: ��� 1�..1�✓��. C-dP''- Town Vail Contracto egistrati n No: `-( c�.g` � 1 � ��� x - Contractor Sig ure ( equired) Property Information Parcel #: � Z-� �� �F`'�� �� � Legal Description: Lot # Blk # ' Subdivision: A�c-ESS � ��}� �. �f on"I�G �CI • ��,ul ' Job Name: �����CG C��� �pu.�r"'�°��_% ' Owner Name: C rC C�C�� ���ncv�U,.}� Ccv�ic��`�� Mailing Address: (For Parcel # Contact Eagle County assessors Office at 970-328-8640 or visit www.eaglecounty. us/patie) Architect� Designer ( ) Engineer ( ) Name: �a-u� . `.Jc�'OG Phone: 1'���- �`�" 3ZZ� Fax: E-Mail: �5 Project #: i�Rs(i� ` �� `I I Building Permit #: '�(} _ ' d t��� Electrical Permit #: L� ��� ���� Detailed Description of Work: �;r•i �7s�ll Z�� ��e�vi�x- r�c�-c� �i w<rC4 �IL �.�1�, �O �� c�£� Cae.x r+�j .. (Use additional sheet if necessary) COMPLETE SQ. FOOTAGE FOR AREA OF WORK AND VALUATION OF WORK (Labor & Material) Amount of SQ Ft �,� 54 ��• Electrical $ ��OG . C�iCs Work Class: New � Addition ( ) Remodel ( ) Repair ( ) Other ( ) Building Type: Single-Family ( ) Two-Family ( ) Multi-Family ( ) Commercial (}� Townhome ( ) Other ( ) Date Received: --�-- - �--� (`� � I � 1I ���! � ' c'� I �1, '�� � �`�� '�P` � �' � � R r �_, _ ' / � , �s � � ��,� �� �" ��°� d � _ ' �tor �. �r i ' � Amendment to the 2002 N.E.C. Town of Vail Ordinance 4, Series_of 2005 ❑ Overhead services are not allowed in the Town of Vail. ❑ Underground services shall be in conduit (PVC) from the ufilify transformer to the electric meter, main disconnect switch, and to the first electrical distribution circuit breaker panel. ❑ The main disconnect switch shall be readily accessib/e, and located next to the meter on the exterior wall of the structure. All underground conduits are required to be inspected before back-filling the trench. ❑ In multi-family dwelling units, no electrical wiring or feeder cables shall pass from one unit to another. Common walls and spaces are exempt. ❑ NM Cable (Romex) can be used only in single and multi-family dwellings. Type NM cannot be used in any building mixed wifh Type A,B.E,F,H,I,M &S occupancies. ❑ Aluminum conductors smaller than size #8 are not permitted. TOWN OF VAIL ELECTRICAL PERMIT GUIDELINES ❑ All installations of exterior hot tubs or spa's require a DRB approval from planning. This application will not be accepted without a copy of the DRB approval form attached (if applicable). ❑ If this permit is for installation of an exterior hot tub or spa on a new elevated platform or deck over 30" above grade, you must also obtain a building permit. ❑ If this permit is for installation of an exterior hot tub or spa on any existing deck or elevated platform, a structural engineer must review the existing condition and verify that it will support the added concentrated load. Please provide a copy of the structural engineers wet stamped letter or drawing with this application. ❑ If this is a remodel in a multi-family building with a homeowners association, a letter of permission from the association is required. ❑ If this permit is for a commercial space, two (2) sets of stamped drawings are required. Electrical one-line and panel schedules are required if load is added or disfribution is altered. I have read and understand the above. Signature Date Signed If you have any questions regarding the above information or have additional questions, please contact the Town of Vail Electrical Inspector at 970-479-2147. The inspector can be reached on Monday thru Friday mornings between the hours of 8am and 9am. You may also leave a voice mail and the inspector will call you back. TOWN'� AIL FIRE DEPARTMENT 75 S. I'AGE ROAD VAIL• .,1657 970-479-z135 VAIL FIRE DEPARTMENT NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES ALARM PERMIT Job Address: 145 N FRONTAGE RD VAIL Location.....: 145 N. FRONTAGE RD W. Parcel No...: 210106409001 Project No : f'�.,� � �— d� `� �- OVdNER TOWN OF VAIL 75 S FRONTAGE RD W VAIL CO 81657 APPLICANT WESTFIRE INC 5350 VIVIAN STREET ARVADA CO 80002 License: 702-5 CONTRACTOR WESTFIRE INC 5350 VIVIAN STREET ARVADA CO 80002 License: 702-5 09/09/2009 Permit #: A09-0067 Status . . . : ISSUED Applied . . : 09/09/2009 Issued . . : 10/26/2009 Expires . .: 04/24/2010 09/09/2009 Phone: (303) 273-9800 09/09/2009 Phone: (303) 273-9800 Desciption: INSTALL THREE PANEL ANTENNAS TO MIDDLE CREEK HOUSING Valuation: $11,000.00 *+**+**a************s*rr�**�***+*******�*�r*************�s**�r+***�a FEE S UMMARY *********�t+*�***r**�****�**********�****�*********��*w»r+** Electrical---------> $ o. o o Total Calculated Fees--> $ � o o. 5 0 DRB Fee---------> $0 . 00 Additional Fees----------> $0 . 00 Investigation----> $ 0. o o "rotal Permit Fee--------> $ 7 0 0. 5 0 W ill CaII---------> $ 0. 0 0 Payments------------------> $ 7 0 0. 5 0 TOTAL FEES--> $700 . 50 BALANCE DUE--------> $0 . 00 **:+»+*»�*+�*�s*��**�*�r******rv+s*vr*r�*****r*+�+��***��***********�*****■rsr*+*****«r++*sr��***�+�+*+***�*���****r*r*:+****�*�**r***+*�*�+*�*t+ Approvals: Item: 05600 FIRE DEPARTMENT 09/23/2009 mvaughan Action: DN show titteen minute alarm time. Recalculatf requirement. Protect heated enclosure. Include knox box. Contractor advised. 10/13/2009 mlv Action: AP alarm panel and extinguishing agent tank a: adjacent to the entrance. ***.*.*****�«�**+**.,*****.,�,:.*.*..*�*�*:«�****.*�***�+*..*,*.***,.***�*****�**�**.******.*�***,:*.*.*,:�***.*.*.***,:�.�**�*.*.*.*�***�.*.****.,. CONDITIONS OF APPROVAL �nd : 5 2 nitored fire alarm system required and shall comply with NFPA 72 (2002 ed.) and VFES indards �*.�*�*.**.*«**.�*..*.��+�***���.*�*�*.*�*�#�*�*+******�***�***.«.*.***��*.��.��*����*�+��***�*�*�*.*�***��.�*.*.����..,.*.��.«.*,.*�*�*.... DECLARATIONS I hereby � 'edge that I have read this application, filled out in full the information required, completed an accurate plot plan, and st af al�''the information as required is correct. I agree to comply with the information and plot plan, to comply with all Towrr.,. .•,nances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQI!ES"1'S FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE B ELEPHONE AT 970-479-2252 FROM 8:00 AM - 5 PM. ✓ - ��---- _ �-�,�-y� iG� G� /< SIGNATURE O'F OWNER OR CONTRACTOR FOR HIMSELF AND OWNER ****************************************************************+****************++*+*+*+*** TOWN OF VAIL, COLORADO Statement ******************+****************************+*********�*�******�************************* Statement Number: R090001536 Amount: $700.50 10/26/200901:57 PM Payment Method: Check Init: JLE Notation: 2091 westfire ----------------------------------------------------------------------------- Permit No: Parcel No: Site Address: Location: A09-0067 Type: 2101-064-0900-1 145 N FRONTAGE RD VAIL 145 N. FRONTAGE RD W. ALARM PERMIT Total Fees: $700.50 This Payment: $700.50 Total ALL Pmts: $700.50 Balance: $0.00 ******************************************************************************************** ACCOUNT ITEM LIST: Account Code -------------------- BP 00100003111100 PF 00100003112300 Description ------------------------------ FIRE ALARM PERMIT FEES PLAN CHECK FEES Current Pmts 412.50 288.00 ----------------------------------------------------------------------------- September 16, 2008 � Cricket Communications 5680 Greenwood Plaza Boule� Greenwood Village, CO 80111 Attn: Ms. Kathy Covillo ����Mf� �; 1 �� w �.i'+� + i �'v'' Suite 500 TOWN C�� V�+IL 1 ��rr�con � Consulting Engineers and Scientists 10625 West I-70 Frontage Road North Suite 3 Wheat Ridge Colorado 80033 Phone (303) 423-3300 Fax (303) 423-3353 www.terracon.com Re: Geotechnical Engineering Report Proposed Cricket Tower Site — DEN-448B Vail Middle Creek 145 N. Frontage Road West Vail, Colorado Terracon Project No. 25085182 Dear Ms. Covillo, Terracon Consultants, Inc. (Terracon) has completed a geotechnical engineering exploration for the proposed Cricket equipment shelter to be located near the existing building at 145 N. Frontage Road West in Vail, Colorado. This study was performed in general accordance with our Master Professional Services Agreement, dated March 15, 2005, amended March 30, 2007. The purpose of these services is to provide geotechnical engineering recommendations for design of foundations and other earth connected phases of the project. Proposed Construction: As currently planned, construction on the site will include the proposed ancillary support equipment shelter with plan dimensions of about 12 by 20 feet. The proposed ancillary support equipment is in support of antennas that will be mounted on the roof of the existing building. Foundation loads for the proposed ancillary support equipment were not available at the time of this study. The ancillary support equipment is considered to be a lightly loaded slab-on-grade structure. Scope of Services: The scope of services performed for this project included site reconnaissance by a field engineer, a subsurface exploration program, laboratory testing and engineering analyses. One boring was drilled near the approximate location of the proposed equipment shelter, shown on the attached Boring Location Map, Figure 1. The boring was drilled with a rotary drill rig with continuous flight solid-stem augers. During the drilling operations, a lithologic log of the boring was recorded by the field engineer. Relatively undisturbed samples were obtained at selected intervals utilizing a 3-inch outside diameter samplers. Disturbed samples were obtained from auger cuttings. Penetration resistance values were recorded using methods based on the standard penetration test (SPT). This test consists of driving the sampler into the ground with a 140-pound hammer free-falling through a distance of 30 inches. The number of blows required to advance the sampler 12 inches or the interval indicated, is recorded and can be correlated to the standard Delivering Success for Clients and Employees Since 1965 More than 95 Offices Nationwide Geotechnical Engineering Report Proposed Cricket Tower Site — DEN-448B Vail Middle Creek Vail, Colorado Terracon Project No. 25085182 Terracon penetration resistance value (N-value). The blow count values are indicated on the boring logs at the respective sample depths, but are not considered N-values. A manual SPT hammer was used to advance the sampler in the boring performed on this site. A greater efficiency is typically achieved with the automatic hammer compared to the conventional safety hammer operated with a cathead and rope. The standard penetration test provides a reasonable indication of the in-place density of sandy type materials, but only provides an indication of the relative stiffness of cohesive materials since the blow count in these soils may be affected by the soils moisture content. In addition, considerable care should be exercised in interpreting the blow counts in gravelly soils, particularly where the size of the gravel particle exceeds the inside diameter of the sampler. A lithologic log of the test boring was recorded by the field engineer during drilling operations. Groundwater measurements were obtained in the test boring at the time of site exploration. The boring was immediately backfilled following the completion of drilling operations for safety considerations. Therefore, a subsequent groundwater measurement was not obtained. The samples retrieved during the field exploration were returned to the laboratory for observation by the project geotechnical engineer and were classified in general accordance with the attached Unified Soil Classification System. At that time, an applicable laboratory- testing program was formulated to determine engineering properties of the subsurface materials. Selected soil samples were tested for the following engineering properties: • Water content • Dry density • Consolidation/Expansion . Water soluble sulfate content Resistivity pH Following the completion of the laboratory testing, the field descriptions were confirmed or modified as necessary, and the Log of Boring was prepared and is attached. Subsurface Conditions: As presented on the attached Log of Boring, fill materials consisting of clayey sand with gravel and cobbles were encountered at the ground surface and extended to a depth of about 8-YZ feet below existing site grade, at which auger refusal conditions were encountered. Several attempts were made to advance the boring beyond 8-'/2 feet, with no success. Bedrock was not encountered within the boring to the termination depth. Field penetration test results indicate that the sand soils were loose to medium dense in relative density. 2 Geotechnical Engineering Report Terracon Proposed Cricket Tower Site — DEN-448B Vail Middle Creek Vail, Colorado Terracon Project No. 25085182 Based on our experience, clay soils are generally considered to be low to moderately expansive and sand soils are generally considered to be non- to low expansive. Groundwater was not encountered at the time of exploration. Due to safety considerations, the boring was backfilled with auger cuttings after drilling operations were complete; therefore subsequent groundwater measurements were not performed. These observations represent current groundwater conditions only, and may not be indicative of other times, or at other locations. Groundwater levels can be expected to fluctuate with varying seasonal and weather conditions. Equipment Shelter Support: Drilled Pier Foundation System: Based on the results of the exploration, we recommend the proposed equipment shelter be supported on a drilled pier foundation system. Along with this option, a structural floor system is also recommended for the interior of the equipment shelter. Straight shaft piers with a minimum shaft length of 4 feet are recommended. For axial compression loads, piers may be designed for a maximum end-bearing pressure of 1,500 pounds per square foot (psf. Subsurface parameters for axial compression, uplift loads and lateral soil response is provided in the Summary of Foundation Recommendations Table attached to this report. Uplift forces (if any) on piers should be resisted by a combination of dead load and pier penetration below a depth of 4 feet and in the bearing strata. All piers should be reinforced full depth for the applied axial, lateral and uplift stresses imposed. The amount of reinforcing steel for expansion should be determined by the tensile force created by the uplift force on each pier, with allowance for dead load. To reduce potential uplift forces on piers, use of long grade beam spans to increase individual pier loading and small diameter piers are recommended. For this project, use of a minimum pier diameter of 12 inches is recommended. A minimum 4-inch or greater void space should be provided beneath grade beams between piers. The void material should be of suitable strength to support the weight of fresh concrete used in grade beam construction and to avoid collapse when foundation backfill is placed. Free-fall concrete placement in piers will only be acceptable if provisions are taken to avoid striking the concrete on the sides of the hole or reinforcing steel. The use of a 3 Geotechnical Engineering Report Terracon Proposed Cricket Tower Site — DEN-448B Vail Middle Creek Vail, Colorado Terracon Project No. 25085182 bottom-dump hopper, or an elephant's trunk discharging near the bottom of the hole where concrete segregation will be minimized, is recommended. Pier-bearing surfaces must be cleaned prior to concrete placement. A representative of the geotechnical engineer should observe the bearing surface and pier configuration. Shallow Foundation System: As an alternative, the proposed ancillary equipment structure may be supported on a shallow foundation system. Slab-on-grade construction bearing on the existing soils is considered feasible. For protection against frost heave, all exterior foundations should be constructed at a depth of four feet below the ground surface. If slab on grade construction is desired, it is likely that expansive materials and/or frost heave action could cause the foundations to move approximately 1 to 2 inches. Excavations may require the use of specialized heavy-duty equipment, rippers and pneumatic equipment to facilitate rock break-up and removal. If some movement can be tolerated and spread footing and/or slab-on-grade foundations are utilized, an allowable bearing capacity of 1,500 psf is appropriate for the supporting soils. Any new fill placed for slab support should consist of granular materials and should be compacted to a minimum of 95 percent of the maximum density defined by ASTM D1557, at moisture contents within 3 percent of the optimum moisture content. Should structural loads be concentrated on the perimeter of the slab, a monolithic turn down edge should be considered. Thickened interior slab sections can be used to support concentrated or continuous slab loading provided that: • loads do not exceed 900 plf, . thickened sections have a minimum width of 12 inches, and • thickness and reinforcement are consistent with structural requirements. Foundations and slabs should be reinforced as necessary to reduce the potential for distress caused by differential foundation movement. Foundation excavations should be observed by the geotechnical engineer. If the soil conditions encountered differ significantly from those presented in this report, supplemental recommendations will be required. Seismic Considerations: A site classification "D" should be used for the design of structures for the proposed project (2006 International Building Code, Table No. 1613.5.2). Corrosion Protection: Laboratory test results as part of this study indicate that on-site soils have minimum resistivities ranging from 2,950 to 3,550 ohm-centimeters and pH values ranging from 7.9 to 8.0. These values should be used to determine potential corrosive 4 Geotechnical Engineering Report Proposed Cricket Tower Site — DEN-4486 Vail Middle Creek Vail, Colorado Terracon Project No. 25085182 Terracon characteristics of the on-site soils and bedrock with respect to contact with the various underground materials, which will be used for project construction. General Comments: The Geotechnical Engineer should also be retained to provide services during excavation, grading, foundation and construction phases of the work. Observation of drilled shaft and foundation excavations should be performed prior to placement of reinforcing and concrete to confirm that satisfactory bearing materials are present and is considered a necessary part of continuing geotechnical engineering services for the project. Construction testing, including field and laboratory evaluation of fill, backfill, pavement materials, concrete and steel should be performed to determine whether applicable project requirements have been met. It would be logical for Terracon to provide these additional services for continuing from design through construction and to determine the consistency of field conditions with those data used in our analyses. The analyses and recommendations in this report are based in part upon data obtained from the field exploration. The nature and extent of variations beyond the location of test borings may not become evident until construction. If variations then appear evident, it may be necessary to re-evaluate the recommendations of this report. We have appreciated being of service to you in the geotechnical engineering phase of this project, and are prepared to assist you during the construction phases as well. If you have any questions concerning this report or any of our testing, inspection, design and consulting services, please do not hesitate to contact us. Sincerely, TERRACON CONSULTANTS, INC. �lJ�`.""/VI'l.'.�" � ' .. Melanie K. Longi Staff Geotechnical Engineer Copies to: Addressee (1 via-email) � -,,p0 REG/ � 0�-- ,..... o„ : .�� �. . , .o �: � � 34273 � ; ; q/�b o�, .. 't�� ' ••� \ �n��•s..�• _.�7 Andrew J. G ner, P.E. '`�`-� Geotechnic Department Manager Geotechnical Engineering Report Terracon Proposed Cricket Tower Site — DEN-4486 Vail Middle Creek Vail, Colorado Terracon Project No. 25085182 Summary of Foundation Recommendations Table Allowable Vertical Ultimate Lateral Parameters Parameters Beam on Elastic Foundation LPILE Parameters Layer Depth, k;, coef. of feet Bearing, Skin Passive Hori. Sub. Friction, psf EFP,psf/ft Reaction Sd, psf Y k(static) k(cyclic) (tcf) Soil Code �p�i� Su (psi) � pci pci E5o 0-4 -- -- -- -- -- -- -- 4+ 1550 30 350 4 4 0.067 0 30 25 25 -- Note: Top 48 inches of foundation depth should be ignored due to frost heave. .�y0�'�`� Leqend 1 APPROXIMATE BORING LOCATION PROPOSED EVERCREEN TREE SRE SCREENING (3 TOTAL - MIN. 6' HICH) -EXIST�NG REfAINING WALL a PROPOSED CRICKEf ANTENNA W/ RAD CENTER 6 71' PND AZIMUTH OF 280' � (PAIM TO MATCH IXTERIOR BVIIDING COLOR) PROPOSEO CRICKEf IJ�lUT1' H-HHAME PROPOSED CRICKET COAX LOWER ROUTING INSIDE BUIIAINC AT ROOF � PROPOSED UNOERSIDE OF EXISTING EDCE 3'-8� ACCESS ROOF JOISTS (M')� DOOF w I I� � I I� I I� I I� I I� � ROOF i i l SIOPE I I 1 I I I I I � � � � � � � ;j i ------ ----'1------ ---- -----=a =______-__-�__ � "_��� II I jl 1 T-- 0o I � � ROOF II I 200F PEAK ELEV. 78'-2't SLOPE � ji I il I �� I d I LL� �I � ¢ V�i 4.}I �� r�--------------------------- L____________________________ EXISlINC HIGH ROOF E�GE OVER TOWER RELOCATED TREES < ' _________ �__�' - v -- 1- !�� S�'�''7c ��`� �% REMOVE DCIS7ING j I � � L TREE AND RELOCATE—� � � � �� (21rP) I I I --=-----_ — .. _ �______________ � ---- ----------------- — 7'— — �PROPOSED UNDERGROUND CABLE DUCTBANK PROPOSED 12' VEKTICAL CABI.E TR4Y—D(ACf �—LOCATION TO BE DEfERMINED IN THE Fl0.D (PAIM TO MATCH INTERIOR FlN�SH COLOR) r---� r----i L___J L___J PROPOSED 12'-8"K20'-8" WOOD FRAMED EQUIPMENT SHEITER W/ EIFS EXTERIOR FlNISH (EIFS COLOR AND TEXTURE TO MATCH EXI571NC BUILAINC) a II � I �I I � I HIP ROOF WITH II 3:12 SLOPE AND I� /� 1'-0° OVERHANC m a � i/ (rrP) � M I' I I I �I il 1 LPROPOSED � CftICKET 73'-4'x21'_8• LEASE MEA � PROPOSE� 4'x13' CRICKET EQUIPMENT PLATFORM r---� r' L--_J L J ___'_______ ______________ -- ----------------- L---------- ---------------- �LICHT HIDOEN UNE INOICATES APPROXIMATE LOCATON OF ERISTING WAIL CONSTRUCiION UNDERNEATH THE ft00F (iYP) PROPOSED CRICKET COAX ROUTING INSIDE BUILDING AT UNDERSIDE OF IXISTINC ROOF JOISTS (lYP) �PROPOSED CRICKEf ANTENNA W/ RAD CENTER O 71' PND AZIMUTH OF 110' (PAINT TO MATCH EMFRIOR BUILOING COLOR) +*�� BORING LOCATION MAP FIG. Na MKL � n°BS,BZ 1%rr�cor� Proposed Cricket DEN-4486 Vail Middle Creek MKL �� N.T.S ��ro������ 145 N. Frontage Road West 1 MKL F�6 �-� 10825W.H70Fronleq�RwtlN.,SW1�] V'a��, Colorado AJG � &11/3WB - VJhesiRlOga.COlmtloBON3 - LOG OF BORING NO. 1 pa e 1 of 1 CLIENT Cricket Communications SITE PROJECT Vail, Colorado Proposed Cricket DEN-448B- Vail Middle Creek SAMPLES TESTS O o N m o o � W= � DESCRIPTION � � � w � Z � LL � o � _ _ � m p � wH � Ow °' ot �a v � ar v � a7o � z� v�`"° � � � Z F � m >U � �(n o U(/)J FILL. CLAYEY SAND, fine to coarse SC 1 BS 5 grained, with gravel, trace cobbles, brown, loose to medium dense SC 2 RS 0 32 SC 3 RS 0 10 5 SC 4 BS 15 8.5 BOTTOM OF BORING 0 � � 0 c? f- w F Z O U � � W H a The stratification lines represent the approximate boundary lines * Manual Hammer � between soil and rock types: in-situ, the transition may be gradual. � WATER LEVEL OBSERVATIONS, ft BORING STARTED 9-10-08 � W� � None WD 1 Backfilled BORING COMPLETED 9-10-08 o WL � � �rr�con RIG Unlimited FOREMAN RG o W� APPROVED AJG JOB # 25085182 m 100 95 90 8� 8C 7° 7t � s, _ W 6, m 51 Z 5� LL z 4 w � 4 �W a 3 3 2 � 1 U.S. SIEVE OPENING IN INCHES I U.S. SIEVE NUMBERS I HYDROMETER �nn '� � IYIIYYYIIYIIIIIYYIIIIIIII��IIIIIII�� Il�rli111111►�IYI ".■II�"".�'I!"�'.■I""�,�■I'�",,.■II""'.■ 11��1111111��1111��1��1111111��1111111��1111111�� ". ■ � """. � I "" t , . ■ I """. ■ � " I "' . ■' I ""' . ■ . ■ I I ' ' ' ' ' . � � I ' ' ' � ' � � ' I ' ' ' ' ' . ■ I ' � ' ' ' ' . ■ I ' ' ' � ' ' . ■ " '.■ 1'.■�'�"1'.�I��"".,,I�"'1'.■II""'.■I�"" ".■�I�"".�""'�'.,II"'�'.■II�"".■I�""'.■ 11��1111111��1111111��1�11111��1111111��1111111�� ' ��IIIIIII��IIIIIII��III�111��1111111��1111111�� 11 � 11�� ' �'.■II�"1'.��""�'.■III't,,.■I'�"".■II"' 1 .SI'�"".�II""'.■I""�,.■I'�I"'.■I�""'.■ " '.■ • ".■I'�'I1,.�I""�'.■��"'�„■I��"'1.■I'I"' , ,.■II�"1,.��I""'.■II"'�'.,I'�"".■II"",.■ � � IIII�� � 11��11�1111��1111111��1111111�\IIIIIII��III t .■I��"".���"'�,.■I"I'�'.■I���"'.■II""'.■ " ".■ ".■��'I"'.�I'I'1�'.■II"'�'.■I""1,.■I�"' ' .■II�"".�'I"'�,.■II""'.■��""'.■�""1,.■ 1' '.■ ".■I'�"".�I"I'�'.■�""�'.■I'�",'.■II"" , ■II�"'1.��I"'�,.■II"'�,.■I""".■II"'t1.■ ". ",.■ � ".■I��"".�II""'.■'�""'.■���"1'.■�"' � � �� � GRAVEL COBBLES coarse fine Specimen Identification i�— 5.Oft ecimen Identification D100 � S.Oft 37.5 1 �� rr �con GRAIN SIZE IN MILLIMETERS SAN D coarse medium fine Classification CLAYEY SAND(SC) D60 D30 D10 0.771 0.087 �1 I SILT OR CLAY I LL PL PI Cc Cu 29 20 9 %Gravel %Sand %Silt ` 14.3 57.5 28.2 GRAIN SIZE DISTRIBUTION Project: Proposed Cricket DEN-4486- Vail Middle Creek Site: Vail, Colorado Job #: 25085182 Date: 9-12-08 SOIL PROPERTIES Proposed Cricket Tower Site — DEN-448B Vail Middle Creek Vail, Colorado Terracon Project No. 25085182 Atterberg Expansion Corrosivity Soil Property Percent Limits Passing p Water Remarks BNo g �(ft)h Soil Class. Initial D Initial SuKSFr e Ex ��osion Rohmtcmy Salts (ppm) ��p�y Content #200 Sieve LL PI 9 p o� pH Soluble c (qo) 1 0-5 SC 5 7.9 2,950 5 1 5-10 SC 15 28 29 9 8.0 3,550 Note: Initial Dry Density and Initial Water Content are in-situ values unless otherwise noted. REMARKS 1. Compacted density (approximately 95% of ASTM D698 maximum density at moisture content slightly below optimum). 2. Compacted density (approximately 95% of ASTM D1557 maximum density at moisture content slightly below optimum). 3. Submerged to approximate saturation. 4. Dry density determined from one ring of a multi-ring sample. 5. Visual Classification. 1f�rr�con G � t LEGEND ■ FOUND MONUMENT, MARKED A5 NOTEO � ELECTRIC TRrWSFORMER � TELEPHONE PEDESrAL O GBLE iV PEDESTAL Q WATER MEfER �n. SrORM SEWER INLEf @ CONIFER TREE � CONCRETE ❑ /SPHRIT ■ wu� CItAPHICSCALE '_o o '_a ( Irv FEET 1 I incM1 = 20 fl. DETAIL EXHIBIT i�m' iWia�C ��� � �!! � CRICKET WIRELESS PROJECT SITE NAME: Vail Middle Creek I�BUILDING ENVELOPE���. SEARCH RING NUMBER: DEN-448B � '� Town of Vail, Eagle County, Colorado I � ` \ ao•--� � I' I / I $ '��f `�� �/ _ � zj�.20.6]':� EOUIPMENT 8 � SHELTER WITMIN g �a.a3'.zt.er ` o b LElSE AREA I � / Z + � / r ` � a/ za.z � G1 vpo � 2l.] / lI \ If l '°. � � I I(OCH gLL � I ' . I ' p� . � I � ' c� / d . l I-'. .. •• �%� i 1 1/7 ALUNINUM GP '�. 1k �$ . , �Nf ��A . . � ` ' i IpROkII,yTEER .. ., � � � i (��E Ip E4S ASPHALT���RNE � � .. ``I`• BBG' . �C�S p� ' � � �., � ' ..�1�' EISEMENTAPER pur.... . ' � . , � �_ ------ � ---- � � ------------------ -______ ' � _'_'_ '-'--------i L_� INC HEICHTS: iM OF EmE: 75.4' OF ROOF: ]8.2' PROPoSE� MRENN0.5 EXISTING BUILDING � � " � ' I �RAINAGE AND ' �'- ' UIILf1Y EASEMENi� � �, PER PIAT .�\ . i . . � . � �. , . i .� . . .-.. � �`l . NEDI�UMI OTCNLFRLS�I `<. _'_'_'T �1 ��p �� V I I��O' UTILitt ElSEMENT I � � � I 1 OVERALL EXHIBIT LEASE AREA/EASEMENT EXHIBIT EXISiINC j 8 ^� OWES1' eua�iHC �. $ 4e.z ( g _n iz� � , . % -"�� , . ^ ^ . b n "/ • i � �� � � e; ;� � - -- -__ _l K az,z � . �°�'`I ejej � ��� � r y/ ',h �ep N; 2,i °;y '�m�' o � �� W Za � wl �: . � ` � ,i �°,;=, � ;i �n;� sl.� i ���. �� 'i �', � ` ���- �J`�f `�.�� \ �S � � ,- �'--` _ ec..4�,.�*ii 1p0 � lIL/ HEICHTS: )ROM OF EAVE: 75.4' fJ( OF R00:: ]B.P' `PROPOSED AMENWS � EXISTING 9ui�owc LINE BEARING �ISTMICE L1 N 145]'S6�E 21.6]' LI 5 ]P02'Oa'E 13.33 L3 5 tY5]'S6W 21.6]' La N ]0'o1o4w t3.33 nccess x uram rwseMEr�r LS N 7P02'04Y/ 5.J3' L6 5 005'31'YI 48.76 v r+ asaoss zi.zi LB N SY9'�8'E 10.00 L9 S 9530 52 E 10.03 L10 N Q05'31'E 38.82' L11 N ]P0PO4 15.33' L12 5 19'S]'S61Y 10.00' � PROPERTY DESCRIPTION: Lol 1, Mitltlle Creek Subtlivision, Town of Voil, Eogle County, Colorodo. LEGAL DESCRIPTION OF LEASE AREA: Thot port�on of Lot 1, Middle Creek Subdivisian, recordetl al Reception No. 840623 in the records of the Eogle County Clerk ond Recortlers office, tlescribetl os follws: Commencing ot the sautheast corner of Lot 2, Midtlle Creek Subdivision, thence N 21'34�57'E (beorings ore bosed on geotletic north, occortling to WGS 64 projection. Bearings are olso relotive to the bearings of Mitltlle Creek subdivision if rolated 0'S'31' tlockwise) a tlistance 75.67 (eet to the point of beginning; thence N 19'S7�56"E, 27.67 feeF lhence S 70'07�4"E, 13.33 feeh, thence 5 19'S7'S6"W, 21.67 feet thence N 70'02'04'W, 733J feet feet to the point of beginning. Contoining o calculated area of 289 square feet, more or less. LEGAL DESCRIPTION OF ACCESS AND UTILITY CORRIDOR: Thot portion af Lot i, Mitltlle Creek Su6division, recortled at Reception No. 840623 in the records of the Eoqle County Clerk antl Rerortlers otfice, tlescribed as follws: Commencinq ot the soulhwest comer of Lot 2, Mitltlle Creek Subtlivision, thence N 21'34�57�E (beorings are basetl on geotletic north, occording to WGS 84 projection. Beorings ore olso relotive to the bearings af Mitldle Creek subdivision if rototed 0'S'31" clockwise) a tlistonce of 75.67 feet to the point of beginning; thence N 70'02'04"W, 5.33 feet; thence 5 19'57'56"W, 37.36 teet; thence 5 D'OS'31"W, 48.26 feel; thence N 83'30'S2"W, 21.21 feet; thence N 6'29'D8"E, 10.00 feet to the south line of Lot 2, M�ddle Creek Subd�v�s�on; thence 5 83'30'S2'E, along so�d south iine, a distance o( 10.03 feet to the southeast corner thereof; thence N 0'OS'31"E, along the east line of said Lot 2, a d�stance of 38.82 feet; thence N 19'S7'S6"E, 49.13 feet; thence S 70'02'04"E, 15.33 feet; lhence S 19'S7'S6"W, 10.00 feet to the point ol beginning. Contoining o caiculoted oreo of 1127 squore teet, mare or less. NOTES: GRAPHICSCALE i. The purpose of lhis survey is to tlepict the ezisting physical improvements ot the ^o i time o( the survey antl to define the lim�ts o( a leage area and easements appurtenanl thereto. This survey is nol o hountlary survey nor does it represent u monumented land survey. This survey �s not �ntended to 6e used for the creot�on, �iHFECr� comeyonce, or transfer of ony fee simple parcel. Monuments shown hereon ore 7 inch= 20 ft, for reterence only antl are not intentletl lo be relied upon tor the estoblishment of ony bountlory shown on this tlocument. No monuments were establishetl from th�s survey. 2. This survey tloes not constitute a title seorch by Ciork Land Surveying, Ine. to determine ownership or easements of record. No tille commitment was provided by the client. 3. Beorings ore busetl on geotletic north, occording to WGS 64 projection. Beorings are also relotive to the bearings of Mitldle Creek subdivision if rototed 0'S�31" clockwise. 4. Elevatians are bosetl on NAVD BB tlotum. 5. Fetleroi Emergency Monagement Agency, Flood Insurance Rote Map, community-panel number 08037C0463D, effective tlate December 4, 2007, intliwtes the area in the vicinity of this porcel o( lantl to be a zone X(oreo tletermined to 6e outs�de the 500 yeor flootlpiain.) 6. Easements and pubiic tlocuments shown or notetl on this survey were examinetl as to location ontl purpose antl were not exominetl os to restrictions, enclusions, condit�ons, obl�gations, terms, or as to the righl to graM the same. SURVEYOR'S STATEMENT: On the basis ol my knowletlge, information and belief, I hereby stale antl declare that this tlrowing wos prepored untler my direct supervision to the stontlard of core of surveyors procticing in the State of Colorotlo ontl lhat the informotion shown hereon is t�ue ontl rorrect to the best ol my knowletlge antl belief. This slotement is neither a warronty nor a guorcntee, either expressetl or implietl. RE S . , ♦ ` .� ,.... h9y. 's 32439 y� `v'•s/ze/zooefo �s� .......: . P� NA( �qNO S Mark S. Johannes Colorodo Protessonol Land Surveyor Na. 32439 For and on behalf of Clork Lontl Surveying, Inc. IC e v � s i o n s rvo�;�s � i D� � n ro� i � uan : n«o.a�� mcoio�aom. o� �. m ���i�eaia� o�nss�a. C�C�T ��I..E.SS PR�.�CT Clark Land Surveying, Inc. """' °s ' "s ' '" fi� °"°"°,"""° " "' tt � ,; No. Descnp[ion By Da[e oMe yi r �� ��� ��. aor�i �o m�: -�n m�- n r e Ko�R,��n Boundary�C�PS•Mepping 1. ADDEDLEASE,EASEMENTS,LE(CALS&TITLEREViEN APJ 5/12200R "� pl nl e � � Am..uers��h,tt�� e f m rtif4�o�a��maucrs a.nx���onenma. bared po� df ' n sne�ne SITENAME. Va11M1dC11CCieelC in�� � e �aa�.a � �sim�e.��:�ors�mx��� ����s ea�o�o�, ��mm���.am�,ra�� arMm�n�n �rm.�ertrn���:n�w�n�re��. �n �i 119NonhWehserchAvenue 2. MOVEDLE45EARE.4,UPDATEDESMTS.,&LEGALS AM fi;?J200R -Aama�o��"�dwmCLSls�dmo.�obmmwbyCLStG�mrn�op-:^nm�nmNnow>�, � SEt11\CHRIIVGNLTNIBER:DEN-4�}SB Coiaado5 s CO A0907 woo�rt���n:�rvanie�o=,�.«�,uss:n��.�n�m,�:as�u�wae:q.::a:o��a����.,����. P��. 3. CnTAAdENTSPERTnWNnFVAiL AJN R/?fi/200A _ Fl�oawfrnwuonisa���.45ommcF..lenlE�ungrnryMappineog.o�ym�px. ProjCCt 8157 Draw�lBy: NK Date:O>.Ofi.200k 719.633.6533 FAX 719.E33.88?? No. Checked Hv� M57 Sheer 1 of 1 � 0 � EXISTWG RETAINING WALL �EXISTING PAVED PARKING � PROPOSED CRICKET ANTENNAS W/ RAD CENTER � 71' AND AZIMUTH OF 180' (PAINT TO MATCH EXTERIOR BUILDING COLOR) BOTTOM OF ROOF EAVE ELEV. 75'-4"t �w � °o° �� i[ii 6" NOTE: SHELTER ACCESS DOOR, FRAME AND HARDWARE TO BE A MINIMUM 3/4-HR RATED ASSEMBLY PROPOSED EVERGREEN TREE SITE SCREENING (3 TOTAL - MIN. 6' HIGH) EXISTING RETAINING WALL PROPOSED CRICKET ANTENNA W/ RAD CENTER � 71' AND AZIMUTH OF 280' (PAINT TO MATCH EXTERIOR BUILDING COLOR) � � PROPOSED CRICKET UTILITY H-HRAME PROPOSED CRICKEf COAX � ��\v ROUTING INSIDE BUILDING AT LOWER UNDERSIDE OF EXISTING ROOF `� PROPOSED ROOF JOISTS (TYP)� EDGE� 3'-8' RATED ACCESS DOOR 1'-8„ 0'-8" NOTE: ALL EXTERIOR WALL CONSTRUCTION ON PROPOSED SHELTER TO BE UL DESIGN #U309 (1-HR RATED) RELOCATED TREES --- /------ — —r - - — —�— � -: -- _ -- I �. �I � � i � - \ � � I � i � PROPOSED ,2�—a�xzo�—s° w000 FRAMED EQUIPMENT SHELTER W/ EIFS EXTERIOR FINISH (EIFS COLOR AND TEXTURE TO MATCH EXISTING BUILDING) � - ���I // I � — � I HIP ROOF WITH � , I 3:12 SLOPE AND -- ��1'-0" OVERHANG = �------ ----� �-,..-,�.�.s,� �i l� 1_�,'s�� _.--._ -- '= _ - i j �TMP) � ,,,��� i i � 4 + i � � -� ! , yR , - -. ,,- :- i .- � _ _ _ _ � _ � � �� � � �REMOVE EXISTING � � � i � ----------- ----- ---- i �/ TREE AND RELOCATE-� � �\ i I �___ ____________ ___________�_= I I i i2TYP) I � � I I I � �i � � � I--/ -- �,� �- , I I ' I I� " �� � ------ � _________ ____ -- - --� I I� � � rT--- -----� I I� o o �! � FROPOSEu `� � �I � � ;� I CRICKET �� PROPOSED UNDERGROUND 13'-4"x21'-8" � ROOF ROOF �I I CABLE DUCTBANK LEASE AREA o I I / SLOPE ROOF PEAK ELEV. 78'-2"t SLOPE � �� � I I �� � PROPOSED 12" VERTICAL CABLE TRAY-EXACT I I I� I LOCATION TO BE DETERMINED IN THE FIELD PROPOSED 4'x13' CRICKEi I I I� � (PAINT TO MATCH INTERIOR FINISH COLOR) EQUIPMENT PL4TFORM I I il I I I �a �I I I °o ° jl �-- r----i r----i r----� r— L---J L---J L___J L_ � � � � � cn 4,+II -- I I �I I I �I IL----------------------------.C— —J I -- __—__---___--________—_--_____--_—_—__—__—_----___ �-----------------------------�-- -�- - ---------- --------------------------------------- �LIGHT HIDDEN LINE INDICATES APPROXIMATE �LOCATION OF EXISTING WALL CONSTRUCTION EXISTING HIGH ROOF UNDERNEATH THE ROOF (TYP) EDGE OVER TOWER ELEMENT �EXISTING BUILDING � PROPOSED CRICKEf COAX ROUTING INSIDE BUILDING AT UNDERSIDE OF EXISTING ROOF JOISTS (TYP) PROPOSED CRICKEf ANTENNA W/ RAD CENTER � 71' AND AZIMUTH OF 110' (PAINT TO MATCH EXTERIOR BUILDING COLOR) �,og� sca�: 2' 0 2' 4' 6' „e°-,• c„x,�, i/4"=1' (24z36) 12875 East 42nd Avenue Suite 70 Denver, CO 80239 Office: 720374.1911 Fa�c: 720.374.1890 D natek Y TELECOMMiJNICATIONS SERVICES 7134 Brookwood Drive Brookfield, OH 44403 Phone:800-838-3224 Fax:330-448-4337 www. dynatektel ecom. com DYNATEK 6756 PROI. NO.: DRAWN BY: S.R.M. CHECKED BY: D.C.B. SUBMITTALS 9/26/08 CODE REVIEW COMMENTS 2 9/10/08 CODE REVIEW COMMENTS I 7/IB/OB REDLINE REVISIONS 0 5/19/08 ISSUED FOR REVIEW THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHIC EC'�it?�.1_iF�iT NAME IS.��fC"1LY P�� �\ ° � � �c�'..1/I(�A�. � �r :��� :s � f� 3057�^� � i�9l��i < . - ����� � R�r��� ._ __.�- VAIL MIDDLE CREEK DEN-448B 145 N. FRONTAGE ROAD WEST VAIL, CO 81657 SHEE7 TITLE: ROOF / SITE PLAN SHEET NUMBER: A-1 � .• i -� I � �i � � � � w V °a _ � a z �-I z � � i Q � � � Y U � U N OTE: ANTENNAS ARE TO BE PAINTED TO MATCH EXTERIOR WALL FINISH COIOR UNLESS NOTED OTHERWISE PROPOSED CRICKET ANTENNA W/ RAD CENTER � 71' AND AZIMUTHS OF 180' AND 280' ooOPO.�.,�� ?��i�,�Xz��_8�� WOOD FRAMED EQUIPMENT SHELTER W/ EIFS EXTERIOR FINISH (EIFS COLOR AND TEXTURE TO MATCH EXISTING BUILDING) GRADE (BEYOND) GRADE (BEYOND) PROPOSED RELOCATED TREES (TYP) EXISTING RETAINING WALL Y, SOUTHWEST ELEVATION PEAK OF RC � PROPOSED CRICKET ANTENNA W/ RAD CENTER � 71' AND AZIMUTHS OF 110' EXISTING BUILDING (TYF) n PROPOSED SHELTER ROOF SHINGLES TO MATCH EXISTING BUILDING PROPOSED EVERGREEN TREE SITE SCREENING (3 TOTAL — MIN. 6' HIGH) ��� , \�/ � \�/� ��/ ` /�/ ��/ /�/\ ", �� \ ��. \/ � \ � ' \/ . \\ �, �A : �A. � /�A j�. � i�� i��� / �j: A/ A /��.� �\\/� ; ��\\// ��\�� �!\� \� \� . �� � � N � SCALE: 4' 0 4' 8' 12 i/ie°=i' (iixn) 1/8"=1' (24x36) NOTE: ANTENNAS ARE TO BE PAINTED TO MATCH EXTERIOR WALL FINISH COLOR UNLESS NOTED OTHERWISE PROPOSED CRICKET ANTENNA W/ RAD CENTER � 71' AND AZIMUTHS OF 110' PEAK OF ROOF f 1 � � �0 0 I j n' N / /' / / / � /, , % , ❑ ❑ / ' ,, ❑ i', ' n .. ������ i� ❑ � i � � 2 I NORTHEAST ELEVATION �❑ � v i � PROPOSED CRICKEf ANTENNA W/ RAD CENTER � 71't AND AZIMUTH OF 280' EXISTING BUILDING �NP) +i � PROPOSED SHELTER O ROOF SHINGLES TO � MATCH EXISTING '� F- du����r;c z U PROPOSED 12'-8"x20'-8" o WOOD FRAMED EQUIPMENT � SHELTER W/ EIFS EXTERIOR = � �FINISH (EIFS COLOR AND '_ � TEXTURE TO MATCH � � EXISTING BUILDING) z � Z � � PROPOSED Q — RELOCATED w TREE Y U / ❑ � U / �\��\\/�\�\\%� - .���\�;�' \`�✓\��'���,%,j,��!�;�✓� \/// �/ � / , � i. �// . ����/ � �� GRADE (BEYON � � 12875 East 42nd Avenue Suite 70 Denver, CO 80239 Office: 720374.1911 FaY: 720.3741890 D �atek Y TELECOMMiJNICATIONS SERVICES i 7134 Brookwood Drive Brookfield, OH 44403 Phone:800-838-3224 Fa�c:330-448-4337 www. dynatektel ecom. com DYNAT'EK 6758 PROJ. NO.: DRAWNBY: S.RM. I CHECI{EDBY: D.C.B. SUBMITTALS 2 9/10/08 CODE REVIEW COMMENTS 7/18/08 REDLWE REVISIONS 0 5/19/OB ISSUED POR REVIEW THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCL ER THAN THAT WHI '6�.IENT NAME Y '!° ` � � D�1,�e�i �. `� � �c�i�� � 3d�71's � �.�,.�, � 9�� ��<s Y !,`i r� t.,,� �(�� 4, \� -� - _a...-.�'. VAIL MIDDLE CREEK DEN-448B 145 N. FRONTAGE ROAD WEST VAIL, CO 81657 SHEET TITLE: ELEVATIONS SCALE: 4' 0 4' 8' 12' ��16„=�. ���x��� SHEET NUMBER: 1/8"=1' (24x36) A-3 1 PROPOSED CRICKET 5' H—FRAME TO BE CONSTRUCTED OF 3 YZ" DIA. GALVANIZED COMPACTED BACKFILL 6 ML YELLOW WARNWG TAPE 12875 East 42nd Avenue POSTS AND 1 5/s�� UNI—STRUT AT A HEIGHT OF 7' ABOVE FINISH GRADE. POSTS BE SET IN CONCRETE FOOTING (12" DIA. x 3' DEEP). Suite 70 Denver, CO 80239 Office: 720.374.1911 , ,� �, �� � . Fax: 720.374.1890 PROPOSED CRICKET METER AND MANUAL -- - j� TRANSFER SWITCH LOCATION _ �p �� i N il = ' Ic i D natek ,3. y �3' MIN. �., 3,_6„ _ � �-' ' �� - � � � ,. . � . TELECOMMUNICATIONS SERVICES .... . � � � � . COMPACTED 7134 Brookwood Drive - PROCESSED GRAVEL, Brookfield, OH 44403 � i i 6" MIN. ON ALL 51DES. Phone:800-838-3224 -_ � _: ° � �. , I � 1 2" TYP. {� www.dy a ekt le om.com : , � _ _ --. �_ _ � a T� J � ._ i ..� .., ! I ,.. � . ��I� . . DYNATEK ' .�" �.. y � �� 6758 � _ -- � ------ . ' . . . PROJ. NO.: ----- -_�_._ . . __.__- i ._.. � � � .. ._ . .-- _ ._.. --- ... . . . . .. _ __... . .._ _.. _._. co �.. .. .. .. . ._ .... _.. _. _. . _. .. . _. . . . . , , .� - � . . DRAWNBY: S.R.M. . .. .... ._ ..._. . . _..... ... ... ... .... _ . � .. .. ....... .... . . . . . . , . CHECKEDBY: D.C.B. PROPOSED CRICKET HALOGEN LIGHT SUPPORTED BY A 1" RIGID PROPOSED CRICKETUNDERGROUND CABLE DUCTBANK, CONDUIT. TIMER SWITCH AND A GFI RECEPTICLE MOUNTED ON EDGE �3�-4�� DIA. PVC CONDUITS SUBMITTALS OF PPC CABINET ABOVE TELCO PARTITION. 2 9/10/OB CODE REVIEW COMMENTS I 7/IB/OB REDLWE REVISIONS TYPICAL PLATFORM LAYOUT 2 UNDERGROUND DUCTBANK DETAIL o siieioa issueo FoR Review 1 3/16"x1" HDG SMOOTH THTHISF�ET OFI DOCUMENTSED IN MINIMUM OF 75� OR OBSTRUCTIONS MUST GPS ANTENNA PROPRIETARY BY NATURE. ANY GRATING (19W4) � 270' IN ANY DIRECTION �BE BELOW 15' USE OR DISCLOSURE OTHER THAN z TNAMENISICH R CLIEpT w PROPOSED 4'x13' MODULAR � � FRAME ASSEMBLY `S' � � ^ STEEL40RSGALV4PIPEAINLESS ��� o ` __ o a i � i . �i � r,., � � I I PIPE CAP ;f � W'� ,� ^ �; � J � �,�` [ r� � �,_ � � .i � � � i � � �i . i �r : i�� i � �r i ii � � u�, C�u��J GPS MINIMUM SKY VIEW REOUIREMENTS I I +��{�j��� � � WELDED ADJUSTMENT NUT f' �` _'� �]� � � � i .��J� e' � -;i NOTES: I s"i f' ; ���o����o� ,; � � 3 1 �2" DIA. ICE ; ° ��2 9�Ov� -. � i� �- �� ��" i 1. THE ELEVATION AND LOCATION OF THE GPS BRIDGE SUPPORT �' _ I- -I - A JUSTMENT ANUTTHREAD w/ ANTENNA SHALL BE IN ACCORDANCE WITH THE I I PIPE �,. � - FINAL RF REPORT. I I � DETAIL G (12) HDG 3/4" NUT 2. THE GPS ANTENNA MOUNT IS DESIGNED TO � FASTEN TO A STANDARD 1-1/4" DIAMETER, VAIL MIDDLE CREEK SCHEDULE 40, GALVANIZED STEEL OR DEN-44HB - STAINLESS STEEL PIPE. THE PIPE MUST NOT BE THREADED AT THE ANTENNA MOUNT END. 1 1/4" PIPE TO THE PIPE SHALL BE CUT TO THE REQUIRED 3" PIPE CLAMP DETAIL G HANDT OR MROTARM PIPEI C UTTER TO UASSURE A I45 N. FRONTAGE ROAD WEST SMOOTH AND PERPENDICULAR CUT. A HACK VAIL, CO 81657 SAW SHALL NOT BE USED. THE CUT PIPE END � I I (6) HDG ADJUSTABLE SHALL BE DEBURRED AND SMOOTH IN ORDER SUPPORT LEG w/ 3/8" PAD TO SEAL AGAINST THE NEOPRENE GASKEf BUS BAR GROUNDING KIT SHEET TITLE ATTACHED TO THE ANTENNA MOUNT. 3. IT IS CRITICAL THAT THE GPS ANTENNA IS 1/Z��� COAX CABLE 8" MINIMUM PLATFORM, ICE BRIDGE, MOUNTED SUCH THAT IT IS WITHIN 2 DEGREES BENDING RADIUS PER c� GPS DETAILS 4' OF VERTICAL AND THE BASE OF THE ANTENNA MANUFACTURER'S STANDARD IS WITHIN 2 DEGREES OF LEVEL. #2 AWG BCW SECTION A-A #6 AWG GROUNDING KIT CABLE (PROVIDED SHEET NUMBER: 4. DO NOT SWEEP TEST GPS ANTENNA. WITH KIT) TO GROUND A— A PLATF�RM DETAIL (AS MAUNF. BY EMI 800-453-0050 OR APPROVED EQUAL) 4 Gps DETAILS 3 �T \��\\\\��\����1����I���� ////�//�///// \ 33a o 30 �i� j RF CONFIGURATION O � X � 300 Q ^ 60 j ...., �. .. � .. J Z� � Q� � SECTOR 1 SECTOR 2 SECTOR 3 �" �\ — Z�� �� 90 AZIMUTH 280' 110' 180' ���'' o� � � z4° iz° � ANTENNA Ht (ft) 71' 80' 71' 12875 East 42nd Avenue �2� % \ �A�PHA ��� \ �ii�� zio B0 iso\\\\����� # OF ANTENNAS 1 1 � Suite 70 �SECT n AZIMUr= / h �� //���������IIIIIIIIIII\\\���� Denver, CO 80239 H�8p' U" � S �e�q MAGNEiIC DECLINATION ANTENNA MODEL HBX-6516DS—R2M HBX-6516DS—R2M HBX-6516DS—R2M Office: 720.374.1911 � q2iM� �R� NOTES: ANTENNA MODEL—OTHER _ _ _ Fa�c: 720.374.1890 D 7�p, 1. TYPES AND SIZES OF THE ANTENNA CABLE ARE BASED ON ESTIMATED LENGTHS, PRIOR TO ELECTRICAL DOWN—TILT 0 0 0 N ORDERING CABLE. CONTRACTOR TO VERIFY ACTUAL LENGTH BASED ON CONSTRUCTION ��^ LAYOUT AND NOTIFY PROJECT MANAGER IF ACTUAL LENGTHS EXCEED ESTIMATED LENGTHS. MECHANICAL DOWN—TILT 0 0 ° D natek � m c> GREEN � �� ORANGE CABLE LENGTH (ft) 110' 100' 150' � ° y (TX1/RX1) 2. CONTRACTOR SHALL VERIFY THE DOWNTILT OF EACH ANTENNA WITH A DIGITAL LEVEL. � -' CABLE TYPE (inches) 1 5/8" 1 5/8" 1 5/8" �'' o v 3. CONTRACTOR TO CONFIRM COAX COLOR CODING PRIOR TO CONSTRUCTION. TOP JUMPER LENGTH (ft) 6' 6" g' TELHCOMMUI�TICATIONS SHRVICES 4. COLOR BANDING SHALL BE 2" WIDE ON THE MAIN LINE (5 WRAP MIN.). SPACING TO BOTTOM JUMPER LENGTH (ft) 6' 6' 6' BE 1" BETWEEN CO�ORS. COLOR BAND ON JUMPERS 1" WIDE WITH 1" SPACE. START 7134 Brookwood Drive ANTENNA ALIGNMENT COLOR BANDS 2" BEYOND WEATHERPROOFING. START SECTOR COLOR NEXT TO END Brookfield, OH 44403 CONNECTOR. Phone:800-838-3224 ANTENNA ORIENTATION DETAIL 7 RF CONFIGURATION INFORMATION 6 Fax: 330-448-4337 www. dynatektel ecom. c om DYNATEK 6758 � PR07. NO.: SECTOR C (GAMMA) DRAWNBY: S.RM. GPS MAST SHALL EXTEND A SECTOR B(6ETA) MIN. OF 4" ABOVE TOP HILTI HIT C-20 ANCHORS W/LOCK CHECKEDBY: D.C.B. ANTENNA OF ANTENNA SECTOR A(ALPHA� WASHERS & NUTS (WALL MOUNTED) LAG BOLTS (TRUSS MOUNTED) SUBMITTALS GROUND WIRE W/ HALFSTRAP FASTENER No. CABLES No. OF ANCHORS A + + + + + + DOWNTILT BRACKET 2 3 8" O.D. o COAXIAL CABLE W 1 TO 4 2 11 1/2" �— � —�— � —�— � � � 5 TO B 3 21 1/2" 0�_� ,�+`.� C,�+�� � MOUNTING PIPE ANDREW BUTTERFLY 9 TO 12 3 30 1/2" 0 CABLE HANGER 2 9/10/08 CODE REVIEW COMMENTS ,� �— r� �� �� � � � � � ,�� j'�� FINISH ON I 7/IB/08 REDLINE REVISIONS o STEEL COVER 0 � � � 0 Q i%�� o TO MATCH EXISTING 0 5/19/08 ISSUED FOR REVIEW o BUILDING COLORS NOTE: � � � THE INFORMATION CONTAINED IN 1. USE STAINLE55 STEEL ANCHORS INTO CONCREfE. THIS SET OF DOCUMENTS IS CABINET i0 COAX CONFIGURATION DETAIL S ;:/j � a USE CARBON STEEL ANCHORS WTO BRICK OR MASONRY COAX SUPPORT KIT USE TOGGLE BOLTS INTO STUD WALLS. PROPRIETARY BY NATURE. ANY %;'i � a8" o.C. MAX. USE OR DISCLOSURE OTHER THAN '�% � SEE TABLE BELOW USE SELF TAPPING SHEET METAL SCREWS INTO MEfAL SIDING. THAT WHICH NT LOAM AREA PAVED AREA / � 2. ANCHOR TO BE INSTALLED IN 1/2°0 HOLES DRILLED W/ NAME IS P HILTI CARBIDE TIPPED DRILL BITS. ANCHORS SHALL TWO COURSES OF EXISTING WALL BE INSTALLED PER MANUFACTURER'S RECOMMENDATIONS. +�. '�':. 1-1�2�� BITUMINOUS PAVEMENT 3. DEfAIL 6ASED ON THE USE OF ANDREW AND HILTI. /� � CONTRACTOR MAY SUBSTITUTE EQUAL MATERIALS `' 6 ML YELLOW WARNING TAPE � ,� ,'"'�;� '� FINISH GRADE "HIGH VOLTAGE" #2 GREEN STRANDED ��`����� �, � SAW—CUT TO STRAIGHT EVEN 1/2" COAX JUMPER CADWELDED TO ?.* EDGE BEFORE PAVWG ANTENNA MAST FROM i �= I�,��`�j �- � ` UPPER GROUND 8AR � ������� f' \i t, . 6y � o %; ��j����/ �\ • S" GRAVEL BASE �� G��r,�/�� �, lf � \//\//�//\ ` �4 b �� s"�� 6 �tti �° � j\/ \ � \\/��\ \\/��/;\ 12„ 6„ ` `.`' � ��; �i, ��; �i� �� ��i TYPICAL ANTENNA DETAIL 4 PROPOSED WALL MOUNTED VERTICAL CABLE TRAY DETAIL 3 "°~---�--- ,� ,��y��� ��� y��� �� �. � �����_!����;!�����! VAIL MIDDLE CREEK !� ��;,� ����� ��.��; coMPacTE� eacKFi�� DEN-448B /!���/��// ��/j\�// �%��� OVER MASTICAAPE COMPACTED ELECTRICAL TAPE #6 GROUND LEAD O PROCESSED GRAVEL, ias N.rRONrn�E RoAD wEST - 6� MIN. ON ALL SIDES SLOT FOR ADJUSTABLE OVER MASTIC TAPE GROUNDING BAND CLAMP 2 BARRELL HYDRAULICALLY VAIL, CO 81657 CLAMP CRIMPED CONNECTION SCHEDULE 40 CONDUITS FOR NEW ELECTRICAL AND TELEPHONE T 1/4"-20 SERVICES SEE UTILITY AND SITE PLANS. PROVIDE APPROVED � HARDWARE Purrr raPE � iF REQUIRED BY aNrENNa SHEET TITLE: PULL BOXES AS REQUIRED, AND COORDINATE INSTALLATION W/ 'I #6 GROUND LEAD CONFIGURATION, EXTEND LEAD W/#2 CONDUCTOR TO �� ANTENNA ALL UTILITY COMPANIES FOR INTERFACING AT TERMINATION GROUNDING GROUND BAR '`�'� POINTS. PROVIDE FULL LENGTH PULL ROPES (TYP.). CLAMP GROUNDING TRENCH DETAILS ASSEMBLY CLAMP SHEET NUMBER: FIGURE 1 FIGURE 2 FIGURE 3 FIGURE 4 FIGURE 5 FIGURE 6 A-5 TYPICAL UTILITY TRENCH DETAIL 2 TYPICAL WEATHERPROOFING DETAILS 1 I� 2" SCH 40 PI! �AWTILEYER WAL MOUNT BRqCKE �P/N= MT 250L 5/8� THRU-BOLTS, 2 PEF BRACKET, 7YP CR►CKET ANTENNA, gRACKE�'S, AND HqRpyyqRE gy OTHERS IX. WALL (CONCREfE BL,,,,,, MYITH STt1CC0) 5 1/2" � [ � � � / � � � � 0 AS?HALT SHINGLES ON �15 FELT ON 3/4" PLYWOOD W� �P'iION �2: (SHINGLE STYLE AND CO OR (�O� 8" TO MATCH EXISTING BUILDING) ANCHORS FOR WOOD FASCIA (pqlM'n � CONCRETE BLOCK VENTED SOFFIT (CONTINUOUS) - 5/8" DENSGOLp FlREGUARp-, -1/2' X ���1 ON INSIDE AND �4` BACKER BOTTOM OF WALL. �-ATE �24� U309 UL WALL q35EMBLY >NC) 1' EIFS OVER 5/8' DENSGOLD FIREGUARD DRYW,qLL ON 5/8"� EXTERIOR PLYWOOD SUBSTRqTE (1QD NAILS O g` OC EDGE AND 12" OC IN PANEL) (EIFS COLOR AND TEXTURE TO MATCH EXISTING BUILDING) l �� 6� �'�'�" S�w ���� �� 1" EtFS OVER 5/B' DENSGOLD FlREGUARD DRYWpLL ON ALL� ,,,� IXPOSED POSTS Kc� z zo F a� 0 � � 1� ��� � �o �� ' fOJN� `'''0" S(pr �'(6) �4 vEar. aarts (ts' � D P�ER QR 10 ( ) �4 VERT BARS (24' P�ER) W/ �3 gqR "`ni°� v� v a�. Cno �n°.i�i . � vn � S.� 4 24'. 6' OF THE PIER LEMNG7}{ �� / ���� -7 � 12' -J Q�'f ,° e,�:a . ° . . , StMPSON SfRONG-11E H �WN CLIP (OR EQUAL) � 3 �- [�47E: CONTINUOUS RIDGE VENT TO /B�E �INSTqLLEp AT ROOF P \���� — rrct-tNGINEERED WOOD TRUSS ROOF SYSTEM, 'fRUSS MEMBERS O 24" O.C. MAX. (DESIGNED BY OTHERS) W/ 5/8" DENSGOLD FIREGUARD DRYWqu ON UNDERSIDE OF iRUSSES. 2x6 HEADER BEfWEEN POSTS - A7TACH TO POST yy�}{ SIMPSON CONNECTOR 4x4 WOOD COWMN O 4' O.C. MAX. INFlLL BE7WEEN P057g W/ � I YER77CAL 2x4 AT 16' O.0 MAX. . -DOUBLE 2X4 ELEVATED BOTfOM PL4TE BEiWEEN POSTS. WOOD LATfICE -i/2'x4'x4' GALV. STEEL "U" ANCHOR W/ 1/2"x24' ANCHOR B�LT 6' COMPACTED GRAVE� QN 6. MIL VAPOR BARRtER ON COMPACTED F1LL "-18' OR � 2�` DIA. CONCRETE PIER - SEE PLAW f 500 PSF SO1L (MIN.) � R-iniuiX/.Y'!A"�" � 9 wi4/1.S�G`%1►oN � 3/4' � r _p• NOTES; / � � \ r- � — — �-- � � / . , � � \ / �w `\ ` \ J / ` / \ 24' D{A, / • \ CONCREfE PtER � _ 1 � x4 / � � ROOF-LINE ABOVE / / � / / . / � — � �� � � � � � � ` � 18� DG1. 24" DfA. � / � �ONCREiE PfER C6NCRETE PIER � / O 4` O_G. MAX. X4 � c� r�► / co�tcR� \ j / . \ E � , / �� / \ /� \ � � � 1 — _ _ _ \� � J � ` ,� FIXA1fDiQTIOwl'L4N — — — v V2' - r =a- (� � I I / � f �-Fi \ �� � �� / f � i I 0 f io a'� o� �v 7. DESIGN PER IBC 1603.1 2. SPECIAL INSPECTION REQUIRED FOR FOUNDATION PER IBC 1704.4 - INSPECTIQN SHALL gE PERFORMED BY q QUq(,�FIED INSPECTOR. STRUCTURAL NoTES � 1.0 GENERqL CQNDfCI0N5 THE �BCt 20 6 EdR10N�2008� BAEC D ALL OTHER qpPUC,qBLE TO STATE CO�F�. ORDINANCES, AND REGULATIONS. IN CASE OF CONFl1CT BEryyEEAi 7}{E CODES, StqP�pqRDS, ,qND RE6UtATIONS. SPECtFlCAT10NS, GENERAL NOTES AND/OR MANUFACTURER'S REQUIREMENTS, tJSE THE M05T STRINGENT PROVISION. 1.2 IT IS TME IXPRESS INTENT OF THE PAR71E5 iNVOLVED IN THtS PROJECT THAT THE COMRpCTpR OR SUBCONTRqCTOR OR INDEPENDENT CO►�7RqCTpR OR THEIR RESPECTNE EMPLOYEES gHqLL IXCULPATE THE ARCHITECT, THE ENGINEER, THE CONSTRUCi10N MANA�ER. THE OWNER, AND THEIR AGENTS, F7i0M ANy LIqg�Lfn• INHATSOEVER AND HOLD 7}{EM HARMLESS AGAINST LOSS, DAMAGES, LIABILI7Y OR ANY p(pENSE ARISING IN ANY MA7TER FROM THE WORKGlN ACCORDANCE WfTHC7jiE CONTRACT DOCUM N�T'S�, pRT�{E C�NSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES OR FAILURE TO CONFORM TO THE STATE SCAFFpLp�NG ACT IN CONNECTIpN WITIi 'fF{E WORK. �.3 DO NOT SCAI.E pR,qµr�NGS. �•4 VER�FY ALL EQUIPMENT MOUNTING DIMENSIONS PER MANUFqCTURER DRAWINGS. 1.5 SUBMR ONE SEPIA ANp 7yy0 PRINTS OF ALL 5'iRUC7'URq�, SHOP URAWINGS. MARKED UP SEPIA SHqLL BE RETURNED. f .6 DESIGN LOADS ARE: WIN6 SPEED 100 MPH 3 SEC IXP C SOSMIC ZONE � S�w ��� 10D PSF 2.d 51'EEL 2.t MEEf OR D(CEED THE FOLLOWING CODES dc 5'i'qNDARDS MT�T' EDRION) IXCEPT AS NOTED; A' ����- �'iEEL..-.AISC SPECIFlCATION dc CODE OF STqWDARD P HAPS ESE AND PLATES...ASTM A572 r��� �GVI VR I.VW t'VRMGU...I1J -PIPES..ASTA�1 A 53, GRADE B �"' n�03, Giin^u� � -STRUGTl1RAL SHEECS, HQT ROLLED..ASTA,1 q 510 -COlU fORMEQ STEEL 7Ug�NG...qSTM A 500 GRApE g -BOLTS, NUtS dc ►y,qSH�S FOR ANCHOR BOLTS AND SECONDARY CONNECTIONS...ASTM A307 'vJ- STm- SHALL BE HOT-DIPPED GALVANIZED. g. ��S..�M� E 70XX IXCEPTION IS TAKEN TO AISC CODE OF STAMpqRp pRqCT10E PARAGRAPH 4.2.1 REGARDING OWNERS AND FABRICATOR'S RESPONSIBILlTY FOR CONNECTION DESIGN AND DETqILING IS THE CONTRqCTpRS RESPONSIBILITY. EN�INEER'S RtViEW OF SHOP � URAWfN6S tS FOR GENERqI. CpN51DERATIONS ONLY AND DOES NOT CONSTfR1TE qN q�CEPTANCE OF THESE RESPONSIBILITIES gY THE �WP1ER AND/OR ENGINEER. 3.0 SFqt�lpqRDS FOR ALL CONCREfE WORK ��� �a� � � RCING�INLCONFORMANCE WITH'ACI.BSP66�88 OR LqTEST, DETAfLEDSOR AUTHORIZmFBYCTHE STRUCIIJRALE ENG NEE_�RC Lqp � SPLICES WHERE PERMflTED SHAL� BE A MINIMUM OF 30 BAR DIAMETERS. 3.3 PROVIQE qL� ACCESSORIES NECESSARy TO SUPPORT REINFORCING AT POSITIONS SHOW ON DRAWINGS. 3.4 WIRE FABR►C REINFORCEMENT MUST LAP ONE FULL MESH AT SIDE ANp p�p Lqpg Sh6qLL BE T1ED TOGETHER. 3.5 CURE AFfER F(NISHIN� CONCREfE. KEEP MOIST FOR 7 DAYS AFTER POURlNG. 3.6 COMPACT STRUCTU� FILL 95X PROCTOR DENSITY PRIOR TO PUCtNG CONCREiE UNDER SLABS. 3.7 �/4� CHAMFER ON ALL CORNERS AND EDGES. 3.8 ALL CONCRE7E SHALL BE PORTLAND. IYPE 1 CEMENT WITH A MINIMUM OF 28 DAY STRENG7}{ OF 3000 PSI., 4" SLUMP AND q MiNiMUM AIR ENTRqpMEN7' OF 4R. 3•s AL.L REINFORCING STEEL SIiALL BE GRADE 60. ALI. REtNFORCiNG MESH SHALL CONFORM TO ASTAA q 185. ��C � m � VAIL MIDDLE CREEK DEN448B ISSUE DA'fE; 9/29/OS CONSTRUCTION 8/27/OS CONSTRUC110N KS 7/9/OB REV CpNST KS 9/9/OS REV CONST KS 9/29/08 REy CONgT Ks e1 Zuma COnSUI�'dRtS, 717C. 3911 W. 25{h Ave. Denver, C0.80212 P:303-32b-5606 F:3Q3-325-5629 �� � ������ � ;, i � �\�' s � 4 i ♦ j � � \ ��� � . i % , • 4 • � /� . r�++ �a _ � ; - i _� t1,,`,'� � STRUCTURAL FRAMING PLAN, SECTION AND NOTES �� SET FOR A 24'x36' 'D' � � � .� �t �� ._ _. � Y1 _ _ ._ - _..._ �--- _ J_— ._ .. _—�_.__._�__._ 10 ;' i w � 11 � O �� 4 �o ��. ROOF ROOF ��., .. / SLOPE SLOPE �w oa o° �� - _ -- - � _ ....._.. _.... _. - - - __.. _ - _._ ._. _.... .._ _.. ...._ _1, ELECTRICAI, SYN�OLS ►�� � i ��1 � � � 0 ---�--- GROUND ROD WITH ACCESS XIT GROUND ROD GROUND ROD DISCONNECT SWITCH METER ON METER/BREAKER UNIT CIRCUIT BREAKER GENERATOR MECHANICAL TYPE CONNECTION CADWELD TYPE CONNECTION GROUNDING WIRE CB INTERLOCKING MECHANISM ABBREVIATIONS & SYMBOLS � = �o .;,o . -� • _ „ 1 � � � �I O � 5 �O� � ' �� '� -., �"` -- �--- �--- � ---�-- I i I � '' �i . �. I I_... ... , I: r-- ..._ � -_ __ .._.... ._. _. _..__ _-- _... __. . -- - - _.._ _. � . _ ABBREVIATIONS AWG AMERICAN WIRE GAUGE BC7W BARE COPPER TINNED WIRE GPS GLOBAL POSITIONING SYSTEM PCS PERSONAL COMMUNICATION SYSTEM PPC POWER PROTECTION CABINET PRC PRIMARY RADIO CABINET RWY RACEWAY NP� TYPICAL RGS RIGID GALVANIZED STEEL EMT ELECTRICAL MEiALLIC TUBING DWG DRAWING IGR INTERIOR GROUND RING (HALO) ACCA ANTENNA CABLE COVER ASSEMBLY MIGB MASTER ISOLATED GROUND BAR CIBGE COAX ISOLATED GROUND BAR EXTERNAL BTS BASE TRANSMISSION SYSTEM GEN GENERATOR GR GROWTH SICW STRANDED INSULATED COPPER WIRE O.I� KEYED NOTES: � CADWELD #2 AWG BARE TINNED COPPER WIRES FROM EQUIPMENT CABINETS TO GROUND RING. 0 CADWELD #2 AWG BARE TINNED COPPER WIRES FROM PPC CABINET TO GROUND RING. � GROUND TEST WELL SHALL BE INSTALLED ON GROUND RING. � 4"x1/4"x10" TINNED COPPER ANTENNA GROUND BAR (AGB). 0#2 BARE COPPER TINNED GROUND WIRE BURIED 36'" BELOW FINISHED GRADE, AND ATTACHED WITH CADWELD TYPE CONNECTION TO THE GROUND RODS AT BOTH ENDS. 0 CADWELD #2 AWG BARE TINNED COPPER WIRES TO PROPOSED PLATFORM (TYP. 2 PLACES) O 5/8" x 10" COPPER CLAD GROUND ROD. O GROUND LEAD FROM SEPARATE GROUND ROD SHALL CONSIST OF #2 AWG SOLID BARE TINNED COPPER WIRE O 4"x1/4"x20" TINNED COPPER MAIN GROUND BAR (MGB). 70 #2 GREEN JACKETED GROUND CONDUCTOR BETWEEN ANTENNA GROUND BAR (AGB) AND MAIN GROUND BAR (MGB). 11 CADWELD #2 AWG BARE TINNED COPPER WIRE JUMPERS FROM ANTENNA GROUND BARS (AGB) TO EACH ANTENNA MAST. NOTES: 1. ALL GP.CUNDING SYSTEM CONDUCTORS AND CONNECTIONS BELOW GP,ADE SHALL BE THERMAL WELDS ar GROUND RODS AND AT A MINIMUM OF 36" BELOW GRADE. 2. ALL INSTALLATIONS SHALL BE FIELD VERIFIED. 3. ALL GROUND WIRE SHALL BE #2 AWG BARE COPPER TINNED UNLESS NOTED OTHERWISE. 4. ALL GROUND WIRES SHALL PROVIDE A STRAIGHT DOWNWARD PATH TO GROUND WITH GRADUAL BEND AS REQUIRED. GROUND WIRES SHALL NOT BE LOOPED OR SHARPLY BENT. 5. THE CONTRACTOR SHALL COORDINATE INSTALLATION OF GROUND RODS AND GROUND RING WITH FOUNDATION AND UNDERGROUND CONDUIT. 6. EACH LUCENT EQUIPMENT CABINET SHALL BE CONNECTED TO THE #2 BCTW RUNNING ALONG PLATFORM WITH #z AWG INSULATED STRANDED COPPER WIRE. EQUIPMENT CABINETS SHALL EACH HAVE (2) CONNECTIONS. 7. ANTENNA GROUND KITS SHALL BE FURNISHED BY CRICKET AND INSTALLED BY ELECTRICAL CONTRACTOR. 8. KOPR—SHIE�D ANTI—OXIDATION COMPOUND SHALL BE USED ON ALL GROUNDING CONNECTIONS. 9. ALL EXOTHERMIC CONNECTS SHALL BE INSTALLED UTILITIZING THE PROPER CONNECTION/MOLD AND MATERIALS FOR THE PARTICULAR APPUCATION. 70. ALL BOLTED GROUNDING CONNECTIONS SHALL BE INSTALLED WITH A LOCK WASHER UNDER THE NUT. HARDWARE FOR BOLTED CONNECTIONS SHALL BE A MINIMUM OF 3/8° DIAMETER AND SHALL BE STAINLESS STEEL. 11. GROUNDING WIRE SHALL NOT BE INSTALLED OR ROUTED THROUGH HOLES IN ANY METAL OBJECTS OR SUPPORTS TO PRECLUDE ESTABLISH�NG A"CHOKE" POINT. 12. PLASTIC CLIPS OR METAL CLIPS WHICH DO NOT COMPLETELY SURROUND THE GROUNDING CONDUCTORS SHALL BE USED TO FASTEN AND SUPPORT GROUNDING CONDUCTORS. FERROUS METAL CLIPS WHICH COMPLETELY SURROUND THE GROUNDING CONDUCTOR SHALL NOT BE USED. 13. STANDARD BUS BARS (CIGBE AND MIGB) SHALL BE FURNISHED AND INSTALLED. THEY SHALL NOT BE FABRICATED OR MODIFIED IN THE FIELD. 14. THE GROUNDING CONNECTION TO THE POWER AND TELCO SECTIONS OF THE PPC CABINET SHALL BE MADE BY CONNECTING A CONDUCTOR FROM THE GROUND RING TO THE FACTORY FURNISHED BUS BAR IN EACH COMPARTMENT. 15. THE CONTRACTOR SHALL SUPPLY CRICKET WITH RESULTS FROM PRE—CONSTRUCTION (CO—LO ONLY) AND POST—CONSTRUCTION OHM TESTING (GROUND) RESULTS. GROUNDING PLAN & NOTES (NOT SITE SPECIFIC) � 12875 East 42nd Avenue Suite 70 Denver, CO 80239 Office: 720374.1911 Fax: 720.374.1890 D natek Y TELECOMML7NICATIONS SERVICES 7134 Brookwood Drive Brookfield, OH 44403 Phone:800-838-3224 Fae: 330-448-4337 www. dynatektel ecom. com D�nrEx PROJ. NO.: 6758 DRAWNBY: S.R.M. CHECKEDBY: D.C.B. SUBMITTALS 9/10/08 CODE REVIEW COMMENTS 7/18/08 REDLINE REVISIONS 5/19/08 ISSUED FOR REVIEW PRC OR WHI �� � f � i .�' ! ` �.2:g . Qr !ij� '�'v. ����� 3��7%� ��yl4B .�; � � ���{ IN VAIL MIDDLE CREEK DEN-448B i 145 N. FRONTAGE ROAD WEST VAIL, C0 81657 SHEET TITLE: GROUNDiNG pLAN & NOTES SHEET NUMBER: E-1 � SERVICE ENTRANCE RATED 200 A, 2 POLE FUSIBLE DlSCONNECT, NEMA 3R — CLASS FLNR, RK5 FUSES.FUSE AT 200 AMPS 3-3/O, CU + 1 #6 GND IN 2 1/2" CONDUIT NEW PAD MOUNTED TRANSFORMER UTILITY COMPANY 208-240/12DV, 1PJ, METERAND BASE. 3 WIRE, SOKVA ISC = 23,706 EXISTING UTILITY CO. � PAD MOUNTED TRANSFORMER � 500 KVA, 120/208V, 3PJ, 4 WIRE ISC = 124,364 3-350, CU 20, 1 N - � �_J IN 3" SCHEDULE 80 PVC CONDUIT BURIED SERVICE ENTRANCE RATED 30oA, IN GROUND Z POLE FUSIBLE DISCONNECT, NEMA 3R CLASS FLNR, RK5 FUSES.FUSE AT 3Q0 AMPS �`vv��v�' : O 3-3/O, CU + 1 #H GND lN 2 1/2" CONDUIT #2 CU IN 1/2" fd SCHED. 86 PVC (GROUND PER NEC 250.24) � #2 CU IN 1/2" f0 SCHED. 80 PVC (GROUND PER NEC 250-24) 200 A EMERGENCY GENERATOR RECEPTRCLE. NEMA 3R WlCOVER (APPLETON # AR20044RS) VERIFY GONFIGt1R,qTiON AND PART # WITH CRICKET COMMUNICATIONS WP SEE NOTE B ' POWER CABINET PANEL "LPi" 3-#8, CU + 1 #10 GND fN 3t4" CONDUIT ` TRANSTECTOR CABINET, RATED 120/240 VOLTS. 1 SEE ARCHITECTURAL DRP,WINGS FOR MOUNTING - DETAfLS. UL 691 LISTED. MAINTA[N REQUIRED WORKING CLEARANCES AND MAINTAIN CLEARANCES FROM ANY COMBUSTBLE MATERIALS, PER NEC 408.17. 1. ALL ELECTRICAL WORK SHALL BE DONE IN ACCORDAFVCE U{�ETH CUF�RENT NATtONAL ELECTR(C CODES AND ALL LOCAL ANB STATE CODES, LAWS, AND ORDINANCES. PROVfdE ALL CdMPONENTS RND WIRING 51ZES AS REQUfREQ TO MEET NEC. Z. POWER SERVlCE5 RE4UIREMENTS SHALL BE COMMERCIALAC NOMtNAL t20l2D8 VdLTOR 12D/240 VOLT, SfNGLE FffA&E WtTH 200 AMP RATWG. CONTRACTOR SFiALL CdNTACT LOCAL POWER COMPANY FOR RE4UiREMENTS QF POWER SERVICE LINE TO FHE MEFER BASE. 3. NOT USE�. 4. CQNTRACTOR SFiALL PROVIDE METER BASE AND DlSCONNECT PANELS PER LOCAL POWER COMPANY SPECfFtCAiiOFfS RNQ REQUIREMENTS. POWER COMPANY SHOULD PROVtDE THE 200 AMP SERVtCE. 5. CRICfCEF SIiALL RROVlDE THE TRANSTECTOR POWER GAB(NET AND TELCO FACILITY ENCLOSURE. CONTR,4CTOR TO FURMISH AND INSTAL! METER BASE, FUSED D[SCONNEGT SWfiCH AND UTtLITIES MOUNTt[VG STAND. THE METER BASE SHOULD BE LOCATEQ IN A MANNER WHERE ACCESSIBLE FOR RERDtNG BY THE POWER COMPANY. 6. UNDERGR�UHD POWER AND TELCO SERVICE LINES SHALL BE RQUTED IN A COMMON TRENCH AS MUCH RS PRRCTiCAL. ALL UNDERGROUND COhtDUiT SHALL PVC &CHEDULE 40. CONDUfT IXPOSED ABOVE GROUNQ SHALL BE RIGID GAtVANIZED STEEL UNLESS OTHERWISE [NQICATED. POWER GONDU{T SHALL BE SfZED AS REQUfRED PER CABLE SIZWG AND NEC REQUIREMEhffS. 7. NOF USED. - 8. ENDS OF CONDUITS ALONG PAD FOR SERVECE TQ EQUtPMENT SNALL BE STU66ED AND CAPPED AT 6" ' ABOVE GRRDE, tF SERVICE LfNES CAN'T 6E INSTALLED INtTfALLY, PROVIDE NYLON PULL CORD IN CONDUIT, a S. THESE TWO BREAKERS ARE fNTERLOCKED TO dPERATE AS A'TRANSFER SWITCH" SUCH i'HAT ONLY ONE BREAKER SFWL� BE !N THE "QN" POSfT10N ATANY ONE 1'IME 10. GENERR! CONTRACTOR TO SUPPLY (1} 2 POLE 40 AMP Bk�EAKER. hfOTE t0` OF EXCESS POWERFFELCO CABLE TO BE LEFTAT CFAD END FOR HOOK UP. HdLY GROSS ENERGY NO� THE ELEGTRtCAL CONTR4CTOR SHA�L SUBMITAND COORDINATE THE ELECTRICAL E4ti(RMENTAND ELECTRICAL SERVICE ARRANGEMENT AND LOCATIOMS WfTH THE ENGINEERING DEPARTMENTAND METER SHOP QF THE LOCAL UTILITY COMPANY FOR FAULT CURRENT R,4TING AND SEQl3ENCiNG. OBTAIN WRITTEN APPROVALS PRIOR TO FINAt PRICtNG AND EQUIPMENT ORDER. OBTAIN AGREEMENT dF MEiER AND TRANSFORMER SfZE AND LOCATIONS PRtOR TO WORK. GENERAL NOTES 1. COORDINATE ANY AND ALL POWER OUTAGES WITH PROPERTY OWNERAND UTILITY COMPANY, 2. CONTRACTQR SHALL SUBMITAS-BUILT DRAWtNGSAT PROJECT COMPLETION. FAULT CURRENT CALCUlATIONS FROM PAD MOUNTED 10 TRANSFORMER TO METER _ 2 X 1 Q X 23.706 = 0.8758 F 13923X1X24Q -0.1416 M=�+q418 ISC = 23,706`Q.8758 = 20,762 q FROM METER TO 20�A, 2P DtSC. F_ 2 X 10 X 2D.762 = 0.1243 M= � = 0.8894 13923 X 1 X 240 1+.1243 ISC = 20,762'0.6894 = '18,466 A FROM 200A, 2P DISC. TQ PANEL "LP1" F_ 2X25X18.466 _�2�63 M= � i392s X i 7C 24U t f.2%�� = 0-78�5 ISC = 18,466`0.7835 = 14,468 A NV1�5: 7. A�L EQUIPMENT (FUSES, CIRCUIT BRERKERS, BUSStNG, E�'C.) SHALL HAVE A SHORT ClRCUlT RATING EQUA� TO, OR GREATER FHAN, THE AVAfLqg1� SHORT CIRGUIT CURRENT AT THE LOCATION. 2. PANEL IS 24 CIRCUIT. CiRGUfTS NOT INQICATED SHALL BE DESIGNATED AS FUTURE SPACES. ... . � . . •'l�`!:�t.�!t5.:11'IG. PA• k'N��%VII;_E. �I'�I• CHEaRY rii_i . NJ . GRGYc . i1'. =A . i�o n eaucn e'oea svese Ornva CIry. PA t6127 Phortc (7'24) 458-804D FaX (724) 468-dy 92 N'wu'.rpnBnpr.COm a ��� � 12875 East 42nd Avenue Suite 70 Denver, CO 80239 Office: 720.374.1911 F�c: 72p.374.1 S90 ! D na.tek Y TELECOMMUNICATIONS SERVICES 7134 Brookwood Brive Brookfield, OH 444Q3 Phone:800-838-3224 Fa�c; 330-448-433T www.dynatekfelecom. com DYNqTEK PROJ. NO.: 6758 DRAWNBY: S.RM. �CEIECKED BY: D.C.B. SUBMITTALS � 0 5/I/OB fSSUED FOR REYIEM{ THE INFORMATtOfY CONT,4fNED fht THIS SET OF DC1Ct1NEENFFS fS USE�OR�DISCLOSURE THER F AH N THAT WH[CH RELATES TO CL[ENT NAME IS STRICTLY PROHtBfTEd. � �•' �� � Lf e� O � Q ��5 `M�C4o'. � 0 :� 4��.�� �`� d . n ti_ t). `•. UD `rS�Ok�t E�'c VAII., MIDDLE CREEK DEN-448B 145 N. FRONTAGE R6AD WESF VAIL, CO 8k657 SHEET TITLE: ELECTRICAL DETAII,S SHEET NUMBER: El.l i GROUND RING #2 AWG BCW � CABLE TO CABLE CADWELD .•: .•:.:•:� �... ,.. ���0'i��• ..... ,���� ,. .;.;.� I GROUND �2 AWG - # 2 awc ecw � � %v"i�%�%.` ��"�u�,'`''> — --{ —.� VERTICAL POST VERTICAL POST CONNECTED NOT CONNECTED TO RING TO RING NOTE: 1. VERTICAL POSTS SHALL BE BONDED TO THE RING AT EACH CORNER AND AT EACH GATE POST. AS A MINIMUM ONE VERTICAL POST SHALL BE BONDED TO THE GROUND RING IN EVERY 100 FOOT STRAIGHT RUN OF FENCE. 2. HORIZONTAL POLES SHALL BE BONDED TO EACH OTHER. 3. BOND EACH HORIZONTAL POLE/BRACE TO EACH OTHER AN� TO EACH VERTICAL POST THAT IS BONDED TO THE EXTERIOR GROUND RWG GATE GROUNDING DETAIL (IF APPLICABLE) i .•'�:• . .•.... . ,.... . , ... ,. ...• .❖:•..o• '•:;�;:;: . SEE NOTE 3 & a .• ..❖• .•. ..... , ..... ...... •���.• p� 6����p� :�:�:�'� .. 2 AWG BCW� ��%` "' CABLE TO CABLE '�' ��� # � _ �CADWELD (TYP.) � � #Z AWG BCW NOTE: � RING GROUND #2 AWG BCW (36" MIN. BELOW GRADE) 1. THE #2 AWG, BCW, FROM THE RING GROUND SHALL BE CADWELDED TO THE POST ABOVE GRADE. 2. BOND EACH HORIZONTAL POLE/BRACE TO EACH OTHER AND TO EACH VERTICAL POLE BONDED TO THE EXTERIOR GROUND RING 3. GATE JUMPER SHALL BE #4/0 AWG WELDING CABLE WITH SLEEVES ON EACH END DESIGNED FOR EXOTHERMIC WELDING. 4. GATE JUMPER SHALL BE INSTALLED SO THAT IT WILL NOT BE SUBJECTED TO DAMAGING STRAIN WHEN GATE IS FULLY OPEN IN EITHER DIRECTION. FENCE GROUNDING DETAIL (IF APPLICABLE) GROUND LEADS (2) TWO HOLE LUG TO BE USED WITH #2 AWG BCW TO GROUND RING. -I GROUND BAR SHALL BE SECURELY FASTENED TO TOWER � I INSULATORS AND MOUNTING BRACKETS� 0 SUPPLIED WITH GROUND BAR O 1/4" THICK x 4" x 10" COPPER GROUND BAR (KOPR–SHIELD COATED). TESSCO 91257 OR EQUAL AT TOWER BOTTOM. �� 0 O o0 0o O O o0 OD D �O � CONTftACTOR TO UTILIZE KOPR-SHIELD (THOMAS & BETTS) ON ALL LUG CONNECTIONS BOTTOM TOWER GROUND BAR DETAIL 10 4 FROM ANTENNA RX TX �TX/RX -� JUMPER REQUIRED ONLY WHEN 1 1/4"0 AND LARGER (TYP.) ANDREW CONNECTOR WEATHERPROOFING- KIT (TYP.) FROM ANTENNA FRAME SUPPORT #2 AWG BCW ANTENNA GROUNDING DETAIL � � ¢ Q � o� WEATHERPROOFING ANTENNA CABLE � KIT, ANDREW #2Z�Z�3� (7yp.� WEATHERPROOFING KIT ANDREW �221213 STANDARD ANDREW N6 AWG STRANDED COPPER GROUND WIRE GROUND KIT (TYP.) iGROUNDED TO GROUND BAR) (STANDARD (SEE NOTE) ANDREW GROUNDING KIT) ANTENNA CABLE �TO CABLE TRAY (TYP.) AWG — GROUND BAR �#2 AWG BCW 3 FINISHED GRADE � z '� � CADWELD G —� #2 AWG, TINNED SOLID BCW BURIED GROUND RING �/8"0 x10' LONG COPPERWELD GROUND RODS SPACED � 10' c/c MAX. I 7 I GROUND ROD DETAIL GROUND LEADS (2) TWO HOLE LUG TO BE USED WITH #2 AWG BCW TO GROUND RING. �6 AWG FROM ANTENNA CABLE GROUND KITS. /j� INSULATORS AND MOUNTING BRACKETS (SUPPLIED WITH GROUND BAR) 1/4" THICK x 4" x 20" COPPER GROUND BAR (KOPR–SHIELD COATED). TESSCO 24260 � OR EQUAL. CONTRACTOR TO UTILIZE KOPR–SHIELD (THOMAS & BETTS) ON ALL LUG CONNECTIONS MAIN GROUND BAR DETAIL � 0�� O � � O � o°°�°� � O 0 O O O � O � �O 0 GPS CABLE GROUND ANTEN CABLE 28" APPROX. CABLE GROUND KIT N X 3Z�� I � � ¢ a o � APPROX. N WEATHERPROOFING KIT ANDREW #221213 #6 AWG STRANDED COPPER GROUND WIRE� �-CABLE GROUND KIT (GROUNDED TO GROUND BAR) (STANDARD ANDREW GROUNDING KIT) NOTE: DO NOT INSTALL CABLE GROUNO KIT AT A BEND AND ALWAYS DIRECT GROUND WIRE DOWN TO GROUND BAR. COAX CABLE GROUND #2 SOLID 12" TEST LOOP � Z r� � 2 REMOVABLE COVER, COVER SHALL BE REMOVABLE BY HAND (NO IRRIGATION PLUGS) 8" x 3'-3" MIN. PVC OR CLAY PIPE 1 " SLOT TO ALLOW EXIT/ENTRANCE OF GROUND RING > ' � #2 AWG, TINNED SOLID BCW BURIED GROUND RING 3" OF CRUSHED GRAVEL BELOW WELD. WELD SHALL REMAIN � VISIBLE NOTE: ONE TEST WELL SHALL BE PROVIDED BETWEEN THE TOWER I 6 I GROUND TEST WELL DETAIL GROUND LEADS #6 AWG FROM ANTENNA CABLE GROUND KITS. SECURELY CLAMPED TO TOWER WITH A NON-INSULATING BAND CLAMP MOUNTING BRACKETS (SUPPLIED WITH GROUND BAR) 1/4" THICK x 4" x 10" COPPER GROUND BAR (KOPR-SHIELD COATED). TESSCO 78043 OR E�UAL AT TOWER TOP. CONTRACTOR TO UTILIZE KOPR-SHIELD (THOMAS & BETTS) ON ALL LUG CONNECTIONS TOP TOWER GROUND BAR DETAIL 12875 East 42nd Avenue Suite 70 Denver, CO 80239 Office: 720.374.1911 Fax: 720374.1890 D natek Y TELECOMMT.7NICATIONS SERVICES 7134 Brookwood Drive Brookfield, OH 44403 Phone:800-838-3224 Fax:330-448-4337 www. dynatektelecom. com DYNATEK 6758 PROJ. NO.: DRAWNBY: S.R.M. CHECKEDBY: D.C.B. SUBMITTALS 2 9/10/08 CODE REVIEW COMMENTS I 7/IB/08 REDLINE REVISIONS 0 5/19/08 ISSUED FOR REVIEW THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH� �p,_CLIENT NAME IS n l ��_��,-J / � D��ri� C. 5 3 � �:�,:,,t`�'� ij •��J�i`�'� �'•t`,,� Y z `�/D �' , i ����� A � ��G�" � VAIL MIDDLE CREEK DEN-448B 145 N. FRONTAGE ROAD WEST VAIL, CO 81657 SHEET TITLE: GROUNDING DETAILS SHEET NUMBER: E-2 i t .`ti � � . � � 11� i.11 �� � ��i �� ��il III A/I I'� I'I �% ��i %� I►� � p, . .,..l�nu����l� � �� .t.�m ��i ■� ..•.. ,�='.'-i�� ii�' � u ■� ����m I '\�J n�■ ■�n �� �� � .�� C O � � z� C I� q N s TELCO COMPARTMENT o, � 24 29 OVER/LINDER CABINET 64x30 OUTDOOR AS MANUF. BY TRANSTECTOR SYSTEMS, INC. O 0 0 � m � � MOUNTING HOLES 3/8" BOLTS (4) PL4CES APPLEfON AR20044RS AL.0.125 THICK 1AT FINISH VCLOSURE MCP SERIES SUPPRESSION 200 AMP POSITION SQUARE D LOAD CENTER 200 AMP INTERLOCKED SQUARE D MAIN BREAKERS GFCI CONVENIENCE OUTLET 12 POSITION TERMINAL BLOCK CAT 5 PUNCH DOWN BLOCK 12875 East 42nd Avenue Suite 70 Denver, CO 80239 Office: 720.374.1911 Fa�c: 720.374.1890 D �atek Y TELECOMMLIDIICATIONS SERVICES 7134 Brookwood Drive Brookfield, OH 44403 Phone:800-838-3224 Fa�c: 330-448-4337 www. dynatektelecom. com DYNATEK 6758 PROJ. NO.: DRAWNBY: S.RM. CHECKED BY: D.C.B. SUBMITTALS 2 9/10/08 CODE REVIEW COMMENTS I 7/IB/OB REDLINE REVISIONS 0 5/19/08 ISSUED FOR REVIEW THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY BY l. RE. ANY USE OR DISC' �, T,HAI� TNAMF� YERRT �IT � �� � �,^��ei-� +�,°, f � S k� �" 4.'.'-✓ s r 3u����� ���� �/z 9�a g '` �, ) �'v`i°ti r'� �� �`s � r� VAIL MIDDLE CREEK DEN-448B 145 N. rRONTAGE ROAD WEST VAIL, CO 81657 TSJ SERIES SUPPRESSION SHEET TITLE: ir GROUND BAR PPC CABINET DETAILS SHEET NUMBER: E-3 1 r; TO "T1" CONNECTION /� � � TYPE HS TYPE SS TYPE PT TYPE HA � rrPE Nc 12875 East 42nd Avenue Suite 70 � Denver, CO 80239 N.I. U. � � Office: 720.374.1911 Fax: 720.374.1890 � TYPE GR TYPE VS T1PE XA TYPE GL LUG D natek TYPE GT � TYPICAL CADWELD TYPE CONNECTIONS 1 TEr,ECO�u�cwTrorrs sExvicEs 1. CONTRACTOR SHALL INSPECT THE EXISTWG CONDITIONS 12. INSTALL AN EQUIPMENT GROUNDING CONDUCTOR IN ALL PRIOR TO SUBMITTING BID. ANY QUESTIONS ARISING DURWG THE CONDUITS PER THE SPECIFICATIONS AND NEC. THE EQUIPMENT 7134 Brookwood Drive BID PERIOD IN REGARDS TO THE CONTRACTORS FUNCTIONS, THE GROUNDING CDNDUCTORS SHALL BE BONDED AT ALL JUNCTION BLOOIC$0�d, OH 44403 SCOPE OF WORK, OR ANY OTHER ISSUE RELATED TO THIS BOXES, PULL60XE5, AND ALL DISCONNECT SWITCHES, STARTERS, AND 2�� CONDUIT PROJECT SHALL BE BROUGHT UP DURING THE BID PERIOD WITH EQUIPMENT CABINETS. PhOne: 800-838-3224 THE PROJECT MANAGER FOR CLARIFICATION, NOT AFTER THE Fax: 330-448-4337 CONTRACT HAS BEEN AWARDED. 13. THE CONTRACTOR SHALL PREPARE AS—BUILT DRAWINGS, �y�y�y d ri8t01Ci01000ID.COri1 DOCUMENT ANY AND ALL WIRING AND EQUIPMENT CONDITIONS AND }' 2. LOCATION OF EQUIPMENT, CONDUIT AND DEVICES SHOWN ON CHANGES WHILE COMPLETING iH15 CONTRACT. SUBMIT AT THE DRAWINGS ARE APPROXIMATE AND SHALL BE COORDINATED SUBSTANTIAL COMPLETION. r----- -------', WITH FIELD CONDITIONS PRIOR TO ROUGH—IN. DYNATEK 6758 14. ALL DISCONNECT SWITCHES AND OTHER CONTROLLING DEVICES PROJ.NO.: I 3. THE CONDUIT RUNS AS SHOWN ON THE PI.ANS ARE SHALL BE PROVIDED WITH ENGRAVED LAMICOID NAMEPLATES I I APPROXIMATE. EXAC7 LOCATION AND ROUTING SHAL� BE PER INDICATING EQUIPMENT CONTROLLED, BRANCH CIRCUITS INSTALLED ON, I I EXISTING FIELD CONDITIONS. D��BI: S.R.M I I AND PANEL FIELD LOCATIONS FED FROM (NO EXCEPTIONS.) I I 4. PROVIDE PULL BOXES AND JUNCTION BOXES WHERE SHOWN 15. ALL ELECTRICAL DEVICES AND INSTALLATIONS OF THE DEVICES I I OR REQUIRED BY NEC. CHECKEDBY; D.C.B. I I SHALL COMPLY WITH (ADA) AMERICANS WITH DISABILITIES ACT AS I I ADOPTED BY THE APPLICABLE STATE. 5. ALL CONDUITS SHALL BE MET WITH BENDS MADE W � �� � ACCORDANCE WITH NEC TABLE 346-10. NO RIGHT ANGLE DEVICE 16. PROVIDE CORE DRILLING AS NECESSARY FOR PENETRATIONS OR SUBMITTALS TELCO � OTHER THAN STANDARD CONDUIT ELBOWS WITH 12" MINIMUM RISERS THROUGH BUILDING. DO NOT PENETRATE STRUCTURAL � FACILI7Y � INS�DE SWEEPS FOR ALL CONDUITS 2" OR LARGER. MEMBERS WITHOUT CONSTRUCTION MANAGERS APPROVAL SLEEVES AND/OR PENETRATIONS IN FIRE RATED CONSTRUCTION SHALL BE � ENCLOSURE � 6. ALL CONDUIT TERMINATIONS SHALL BE PROVIDED WITH PACKED WITH FIRE RATED MATERIAL WHICH SHALL MAINTAW THE FIRE i(TRANSTECTOR) i PLASTIC THROAT INSULATING GROUNDING BUSHINGS. RATING OF THE WALL OR STRUCTURE. FILL FOR FLOOR PENETRATIONS SHALL PREVENT PASSAGE OF WATER, SMOKE, FIRE AND FUMES. ALL I I 7. ALL WIRE SHALL BE TYPE THWN, SOLID, ANNEALED COPPER MATERIAL SHALL BE UL APPROVED POR THIS PURPOSE. I I UP TO SIZE #10 AWG (�/8 AND LARGER SHALL BE CONCENTRIC L— _____� STRANDED) 75 DEGREE C, (167 DEGREES F), 987 CONDUCTIVITY, 17. ELECTRICAL CHARACTERISTICS OF ALL EQUIPMENT (NEW AND Z 9�10/OB CODE REVIEW COMMENTS MINIMUM /{12. EXISTING) SHALL BE FIELD VERIFIED WITH THE OWNER'S —�-- REPRESENTATIVE AND EQUIPMENT SUPPLIER PRIOR TO ROUGH—IN OF I 7/18/OB REDLWE REVISIONS NOTE 8 8. ALL WIRES SHALL BE TAGGED AT ALL PULL BOXES, CONDUIT AND WIRE ALL EQUIPMENT SHALL BE PROPERLY J—BOXES, EqUIPMENT BOXES AND CABINETS WITH APPROVED CONNECTED ACCORDING TO THE NAMEPLATE DATA FURNISHED ON 0 5/19/OB ISSUED FOR REVIEW PLASTIC TAGS, ACTION CRAFT, BRADY, OR APPROVED EQUAL. 18. THE EQUIPMENT (THE DESIGN OF THESE PLANS ARE BASED THE INFORMATION CONTAINED IN 2�� CONDUIT 9. ALL NEW MA7ERfAL SHALL HAVE A U.L LABEL. UPON BEST AVAILABLE INFORMATION AT THE TIME OF DESIGN AND THIS SET OF DOCUMENTS IS SOME EQUIPMENT CHARACTERISTICS MAY VARY FROM DESIGN AS PROPRIETARY BY NATURE. ANY 10. CONDUIT ROUGH—IN SHALL BE COORDINATED WITH THE SHOWN ON THESE DRAWINGS). LOCATION OF ALL OUTLET, BOXES, USE OR DISCLOS THAN MECHANICAL EQU�PMENT TO AVOID LOCATION TO CONFLICTS. ETC., AND THE TYPE OF CONNEC710N (PLUG OR �IRECT) SHALL BE THAT WHIC T VERIFY WITH MECHANICAL CONTRACTOR AND COMPLY AS CONFIRMED WITH THE OWNER'S REPRESENTATIVE PRIOR TO ROUGH—IN. NAME I P REQUIRED. 11. ALL PANEL DIRECTORIES SHALL BE TYPEWRITTEN NOT HAND - e( � �- WRI TTEN. y Ra�io caewEr ELECTRICAL NOTES Z �ij F- �n^1/[('�' (�`a i � �rr'„P.��� �' NOTES: � � y����� di . A ELECTRICAL WORK SHALL BE DONE IN ACCORDANCE WITH CURRENT NATIONAL ELECTRIC CODES AND ALL LOCAL AND STATE CODES, IAWS, AND �� g/Z t. t ORDINANCES. PROVIDE ALL COMPONENTS AND WiRING SIZES AS REQUIRED TO MEET NEC. 9�Q� �` ,�._ � . ` �¢� � �R�. 2. POWER SERVICES REQUIREMENTS SHALL BE COMMERCIAL AC NOMINAL 120/208 VOLT OR 120/240 VOLT, SINGLE PHASE WITH 200 AMP RATING. �°�� �,i�; , CONTRACTOR SHALL CONTACT LOCAL POWER COMPANY FOR REQUIREMENTS OF POWER SERVICE LINE TO THE MErER BASE. e 3. CONTRACTOR SHALL ALSO CONTACT LOCAL TELEPHONE COMPANY FOR REQUIREMENTS OF "T1" SERVICE LINE TO TERMINATE AT THE UTILITY MOUNTING VAIL MIDDLE CREEK STAN D. 1 4. CONTRACTOR SHALL PROVIDE METER BASE AND DISCONNECT PANELS PER LOCAL POWER COMPANY SPECIFICATIONS AND REQUIREMENTS. POWER DEN-448B COMPANY SHOULD PROVIDE THE 200 AMP SERVICE. 5. CRICKET SHALL PROVIDE THE TRANSTECTOR POWER CABINET AND TELCO FACILITY ENCLOSURE. CONTRACTOR TO FURNISH AND INSTALL MEfER BASE, FUSED DISCONNECT SWITCH AND UTILITIES MOUNTWG STAND. THE METER BASE SHOULD BE LOCATED IN A MANNER WHERE ACCESSIBLE FOR READING 145 N. FRONTAGE ROAD WEST BY THE POWER COMPANY. VAIL, Co 81657 6. UNDERGROUND POWER AND TELCO SERVICE LINES SHALL BE ROUTED IN A COMMON TRENCH AS MUCH AS PRACTICAL. ALL UNDERGROUND CONDUIT SHALL PVC SCHEDULE 40. CONDUIT EXPOSED ABOVE GROUND SHALL BE RIGID GALVANIZED STEEL UNLESS OTHERWISE INDICATED. POWER CONDUIT SHEET TITLE: SHALL BE SIZED AS REQUIRED PER CABLE SIZING AND NEC REQUIREMENTS. 7. ALL TELCO CONDUIT LINES SHALL BE 4" CONDUIT UN�ESS NOTED OTHERWISE. ELECTRICAL DETAILS 8� ENDS OF CONDUITS ALONG PAD FOR SERVICE TO EQUIPMENT SHALL BE STUBBED AND CAPPED AT 6" ABOVE GRADE. IF SERVICE LINES CAN'T BE INSTALLED INITIALLY, PROVIDE NYLON PULL CORD IN CONDUIT. SHEET NUMBER: 9. THESE TWO BREAKERS ARE WTERLOCKED TO OPERATE AS A"TRANSFER SWITCH" SUCH THAT ONLY ONE BREAKER SHALL BE IN THE "ON" POSITION AT ANY ONE TIME. POWER & TELCO DISTRIBUTION & INTERCONNECTION SINGLE LI1VE DIAGRAM 4 NOT USED L—� 3 e IMPORTANT NOTE: THE CONTRACTOR MUST PROVIDE CLOSE-OUT DOCUMENTS AT THE FINAL INSPECTION WALK BEFORE PAYMENTS WILL BE MADE. GENERAL REQUIREMENTS 1. THE CONTRACTOR SHALL GIVE AL� NOTICES AND COMPLY WITH ALL LAWS, ORDINANCES, RULES, REGULATIONS, AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY, MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS, AND LOCAL AND STATE JURISDICTIONAL CODES BEARING ON THE PERFORMANCE OF THE WORK. THE WORK PERFCR��IED ON THE PROJECT AND THE MATERIALS INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES, REGULATIONS, AND ORDINANCES. 2. THE ARCHITECT/ENGINEER HAVE MADE EVERY EFFORT TO SET FORTH IN THE CONSTRUCTION AND CONTRACT DOCUMENTS THE COMPLETE SCOPE OF WORK. THE CONTRACTOR BIDDING THE JOB IS NEVERTHELESS CAUTIONED THAT MINOR OMISSIONS OR ERRORS IN THE DRAWINGS AND OR SPECIFICATIONS SHALL NOT EXCUSE SAID CONTRACTOR FORM COMPLETING THE PROJECT AND IMPROVEMENTS IN ACCORDANCE WITH THE INTENT OF THESE DOCUMENTS. 3. THE CONTRACTOR OR BIDDER SHALL BEAR THE RESPONSIBILITY OF NOTIFYING (IN WRITING) CRICKET'S REPRESENTATNE OF ANY CONFLICTS, ERRORS, OR EMISSIONS PRIOR TO THE SUBMISSION OF CONTRACTOR'S PROPOSAL OR PERFORMANCE OF WORK. 4. THE SCOPE OF WORK SHALL INCLUDE FURNISHWG ALL MATERIALS, EQUIPMENT, LABOR AND ALL OTHER MATERIALS AND LABOR DEEMED NECESSARY TO COMPLETE THE WORK/PROJECT AS DESCRIBED THEREIN. 5. THE CONTRACTOR SHALL VISIT THE JOB SITE PRIOR TO THE SUBMISSION OF BIDS OR PERFORMING WORK TO FAMILIARIZE HIMSELF WITH THE FIELD CONDITIONS AND TO VERIFY THAT THE PROJECT CAN BE CONSTRUCTED IN ACCORDANCE WITH THE CONTRACT. 6. THE CONTRACTOR SHALL OBTAIN AUTHORIZATION TO PROCEED WITH CONSTRUCTION PRIOR TO STARTWG WORK ON ANY ITEM NOT CLEARLY DEFINED BY THE CONSTRUCTION DRAWINGS/CONTRACT. 7. THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS ACCORDING TO THE MANUFACTURER'S/VENDOR'S SPECIFICATIONS UNLESS OTHERWISE OR WHERE LOCAL CODES OR ORDINANCES TAKE PRECEDENCE. 8. THE CONTRACTOR SHALL MAINTAIN A FULL SET OF CONSTRUCTION DOCUMENTS AT THE SITE UPDATED WITH THE LATEST REVISIONS AND ADDENDUMS OR CLARIFICATIONS AVAILABLE FOR THE USE BY ALL PERSONNEL INVOLVED WITH THE PROJECT. 9. THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE PROJECT DESCRIBED HEREIN. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, AND PROCEDURES AND FOR COORDINATING ALL PORTIONS OF THE WORK UNDER THE CONTRACT. 10. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL PERMITS AND INSPECTIONS WHICH MAY BE REQUIRED FOR THE WORK BY THE ARCHITECT/ENGWEER, THE STATE, COUNTY OR LOCAL GOVERNMENT AUTHORITY. 11. THE CONTRACTOR SHALL MAKE NECESSARY PROVISIONS TO PROTECT EXISTING IMPROVEMENTS, EASEMENTS, PAVING, CURBING, ETC. DURING CONSTRUCTION. UPON COMPLETION OF WORK, THE CONTRACTOR SHALL REPAIR ANY DAMAGE THAT MAY HAVE OCCURRED DUE TO CONSTRUCTION ON OR ABOUT THE PROPERTY. 12 THE CONTRACTOR SHALL KEEP THE GENERAL WORK AREA CLEAN AND HAZARD FREE DURING CONSTRUCTION AND DISPOSE OF ALL DIRT. DEBRIS, RUBBISH AND REMOVE EQUIPMENT NOT SPECIFIED AS REMAINING ON THE PROPERTY. PREMISES SHALL BE LEFT IN CLEAN CONDITION AND FREE FORM PLAIN SPOTS, DUST OR SMUDGES OF ANY KIND. 13. THE CONTRACTOR SHALL COMPLY WITH ALL PERTINENT SECTIONS OF THE APPLICABLE BUILDING CODES AND ALL OSHA REQUIREMENTS AS THEY APPLY TO THIS PROJECT. 14. THE CONTRACTOR SHALL NOTIFY CRICKET'S REPRESENTATIVE WHERE A CONFLICT OCCURS ON ANY OF THE CONTRACT DOCUMENTS. THE CONTRACTOR IS NOT TO ORDER MATERIAL OR CONSTRUCT ANY PORTION OF THE WORK THAT IS IN CONFUCT UNTIL CONFLICT IS RESOLVED BY CRICKET'S REPRESENTATIVE. 15. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS, ELEVATIONS, PROPERTY LINES, ETC. ON THE JOB. 16. THE CONTRACTOR SHALL NOTIFY THE RF ENGINEER FOR ANTENNA AZIMUTH VERIFICATION (DURING ANTENNA INSTALLATION) PRIOR TO COORDINATING SITE SWEEPING. 17. THE CONTRACTOR SHALL SUBMIT, AT THE END OF THE PROJECT, A COMPLETE SET OF AS-BUILT DRAWINGS TO CRICKET'S PROJECT MANAGER. SITE WORK AND DRAINAGE EARTHWORK, EXCAVATION, AND GRADING PART 1 GENERAL 1.01 WORK INCLUDED: REFER TO SURVEY AND SITE PLAN FOR WORK INCLUDED. 1.02 RELATED WORK A. CONSTRUCTION OF EQUIPMENT FOUNDATIONS B. INSTALLATION OF ANTENNA SYSTEM 1.03 DESCRIPTIONS A. ACCESS ROAD, TURNAROUND AREAS, AND SIRES ARE CONSTRUCTED TO PROVIDE A WELL DRAINED, EASILY MAINTAINED, EVEN SURFACE FOR MATERIAL AND EQUIPMENT DELIVERIES AND MAINTENANCE PERSONNEL ACCESS. 1.04 QUALITY ASSURANCE A. APPLY SOIL STERILIZER IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATION (USE AS NEEDED) B. VEGETATION LANDSCAPING, IF INCLUDED WITHIN THE CONTRACT WILL BE PLACED AND MAINTAWED AS RECOMMENDED BY NURSERY INDUSTRY STANDARDS. 1.05 SEQUENCING A. CONTRACTOR IS RESPONSIBLE FOR LAYOUT AND CONSTRUCTION STAKING. B. GRUB THE COMPLETE ROAD AND SITE AREA PRIOR TO FOUNDATION CONSTRUCTION OR PLACEMENT OF BACKFILL OR SUB-BASE MATERIAL. C. CONSTRUCT TEMPORARY CONSTRUCTION ZONE ALONG ACCESS DRIVE. D. THE SITE AREA WILL BE BROUGHT TO SUB-BASE COURSE ELEVATION AND THE ACCESS ROAD TO BASE COURSE ELEVATION PRIOR TO FORMING FOUNDATIONS. E. APPLY SILT STERILIZER PRIOR TO PLACING BASE MATERIALS. F. IF REQUIRED, GRADE, SEED, FERTILIZE AND MU�CH DISTURBED AREAS IMMEDIATELY AFTER BRINGING THE SITE AND ACCESS ROAD TO BASE ELEVATION. WATER TO ENSURE GROWTH. G. REMOVE EXCESS GRAVEL FROM TEMPORARY CONSTRUCTION ZONE. H. AFTER APPLICATIONS OF FINAL SURFACES, APPLY SOIL STERILIZER TO THE STONE SURFACES. 1.06 SUBMITTALS A. BEFORE CONSTRUCTION 1. IF LANDSCAPING IS APPLICABLE TO THE CONTRACT, SUBMIT TWO COPIES OF THE LANDSCAPING PLAN UNDER NURSERY LETTERHEAD. IF A LANDSCAPE ALLOWANCE IS INCLUDED IN THE CONTRACT, PROVIDE AN ITEMIZED LISTING OF PROPOSED COSTS UNDER NURSERY LETTERHEAD (REFER TO SITE PLAN FOR LANDSCAPING REQUIREMENT). 2. SUBMIT FOR APPROVAL 1/2 CUBIC FOOT OF THE PROPOSED SURFACE COURSE MATERIAL. 3. LANDSCAPING WARRANTY STATEMENT, IF REQUIRED. PART 2 PRODUCTS 2.01 MATERIALS A. ROAD AND SITE MATERIALS; FILL MATERIAL SHALL BE ACCEPTABLE, SELECT FILL SHALL BE IN ACCORDANCE WITH LOCAL DEPARTMENT OF HIGHWAY AND PUBLIC TRANSPORTATION STANDARD SPECIFICATIONS. B. SOIL STERILIZER SHALL BE EPA REGISTERED OF LIQUID COMPOSITION AND OF PRE-EMERGENCE DESIGN. C. SOIL STABIUZER FABRIC SHALL BE MIRAFI OR EQUAL - SOOX AT ACCESS ROAD AND SOAK AT COMPOUND. D. GRAVEL FILL; WELL GRADED, HARD, DURABLE, NATURAL SAND AND GRAVEL, FREE FROM ICE AND SNOW, ROOTS, SOD RUBBISH, AND OTHER DELETERIOUS OR ORGANIC MATTER. MATERIAL SHALL CONFORM TO THE FOLLOWING GRADATION REQUIREMENTS. U. S. SIEVE N0. � PASSING BY WEIGHT 4" 100 1/2" 50-85 #4 40-75 #10 30-60 #40 10-30 #100 5-20 #200 0-8 GRAVEL FILL TO BE PLACED W LIFTS OF 9" MAXIMUM THICKNESS AND COMPACTED TO 95� DENSITY. 2.02 EQUIPMENT A. COMPACTION SHALL BE ACCOMPLISHED BY MECHANICAL MEANS. LARGER AREAS SHALL BE COMPACTED BY SHEEPS FOOT, VIBRATORY OR RUBBER TIED ROLLERS WEIGHING AT LEAST FIVE TONS. SMALLER AREAS SHALL BE COMPACTED BY POWER-DRIVER, HAND HELD TAMPERS. B. PRIOR TO OTHER EXCAVATION AND CONSTRUCTION EFFORTS GRUB ORGANIC MATERIAL TO A MINIMUM OF 6° BELOW ORIGINAL GROUND LEVEL. C. UNLESS OTHERWISE INSTRUCTED BY CRICKET COM. REMOVE TREES, BRUSH AND DEBRIS FROM THE PROPERTY TO AN AUTHORIZED DISPOSAL LOCATION. D. PRIOR TO PLACEMENT OF FILL OR BASE MATERIALS, ROLL THE SOIL. E. WHERE UNSTABLE SOIL CONDITIONS ARE ENCOUNTERED, LINE THE GRUBBED AREAS WITH STABILIZER MAT PRIOR TO PLACEMENT OF FILL OR BASE MATERIAL. 3.03 INSTALLATION A. THE SITE AND TURNAROUND AREAS SHALL BE AT THE SUB-BASE COURSC CLCVATION PRIOR TO � ORMING � OUNDATIONS. GRADE OR FILL THE SITE AND ACCESS ROAD AS REQUIRED TO PRODUCE EVEN DISTRIBUTION OF SPOILS RESULTING FROM FOUNDATION EXCAVATIONS. THE RESULTING GRADE SHALL CORRESPOND WITH SAID SUB-BASE COURSE, ELEVATIONS ARE TO BE CALCULATED FORM FINISHED GRADES OR SLOPES INDICATED. B. CLEAR EXCESS SPOILS, IF ANY, FROM JOB SITE AND DO NOT SPREAD BEYOND THE LIMITS OF CRICKET INC. LEASE PROPERTY UNLESS AUTHORIZED BY PROJECT MANAGER. C. THE ACCE55 ROAD SHALL BE BROUGHT TO BASE COURSE ELEVATION PRIOR TO FOUNDATION CONSTRUCTION. D. DO NOT CREATE DEPRESSIONS WHERE WATER MAY POND. E. THE CONTRACT INCLUDES ALL NECESSARY GRADING, BANKING, DITCHING AND COMPLETE SURFACE COURSE FOR ACCESS ROAD. ALL ROADS OR ROUTES UTILIZED FOR ACCESS TO PUBLIC THOROUGHFARE IS INCLUDED IN SCOPE OF WORK UNLESS OTHERWISE INDICATED. F. WHEN IMPROVING AN EXISTING ACCESS ROAD, GRADE THE EXISTING ROAD TO REMOVE ANY ORGANIC MATTER AND SMOOTH THE SURFACE BEFORE PLACING FILL OR STONE. G. PLACE FILL OR STONE IN 3" MAXIMUM LIFTS AND COMPACT BEFORE PLACING NEXT LIFT. H. THE FINISH GRADE, INCLUDING TOP SURFACE COURSE, SHALL EXTEND A MINIMUM OF 12" BEYOND THE SITE FENCE AND SHALL COVER THE AREA AS INDICATED. I. RIPRAP SHALL BE APPLIED TO THE SIDE SLOPES OF ALL FENCED AREAS, PARKING AREAS AND TO ALL OTHER SLOPES GREATER THAN 2: 1. J. RIPRAP SHALL BE APPLIED TO THE SIDES OF DITCHES OR DRAiNAGE SWALES AS INDICATED ON PLANS. K. RIPRAP ENTIRE DITCH FOR 6'-0" IN ALL DIRECTIONS AT CULVERT OPENINGS. L SEED, FERTILIZER AND STRAW COVER SHALL BE APPLIED TO ALL OTHER DISTURBED AREAS AND DITCHES, DRAINAGE, SWALES, NOT OTHERWISE RIP-RAPPED. M. UNDER NO CIRCUMSTANCES SHALL DITCHES, SWALES OR CULVERTS BE PLACED SO THEY DIRECT WATER TOWARDS, OR PERMIT STANDING WATER IMMEDIATELY ADJACENT TO SITE. IF OWNER DESIGNS OR IF DESIGN ELEVATIONS CONFLICT WITH THIS GUIDANCE ADVISE THE OWNER IMMEDIATELY. 12875 East 42nd Avenue Suite 70 Denver, CO 80239 Office: 720374.1911 Fax: 720.374.1890 D natek Y �� TELECOMMUNICATIONS SERVICES 7134 Brookwood Drive Brookfield, OH 44403 Phone:800-838-3224 Fa�c: 330-448-4337 www. dynatektel ecom. com DYNATEK 6758 PROJ. NO.: DRAWNBY: S.R.M. CHECKED BY: D.C.B. SUBMITTALS 2 9/10/08 CODE REVIEW COMMENTS I 7/IB/OB REDLINE REVISIONS 0 5/19/OB ISSUED FOR REVIEW THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY BY URE. ANY USE OR DIS �p. �R.THA� TNAME Tf�f �tYE��l�l�9.? 1� � y- i �-...i5-- L1����� �, ° � e���-��i0 ' r�:: �-,. � �+��r /� �,fi�AF, `1' z 9�Ov i' �;� � /p�y7 as � _4�"� ��� , VAIL MIDDLE CREEK DEN-448B 145 N. FRONTAGE ROAD WEST VAIL, CO 81657 SHEET TITLE: GENERAL NOTES SHEET NUMBER: GN-1 Ir i . * � N, IF A DITCH LIES WITH SLOPES GREATER THAN TEN PERCENT, MOUND DIVERSIONARY HEAD`NALLS IN THE DITCH FOR 6'-0" ABOVE THE CULVERT ENTRANCE. �, SEED AND FERTILIZER SHALL BE APPLIED TO SURFACE CONDITIONS WHICH WILL ENCOURAGE ROOTING. RAKE AREAS TO BE SEEDED TO EVEN THE SURFACE AND TO LOOSEN THE SOIL. RECOMMENDEDEBYNTHE �SEEDEPRODUCER.TWICE THE QUANTITY q, IT IS TNE CONTRACTOR'S RESPONSIBILITY TO ENSURE GROWTH OF REL�EA�SEAFROMATHECCONTRACT.ASCONTNUERTOGREWORK BAREOINT AREAS UNTIL COMPLETE COVERAGE IS OBTAWED. 3.04 FIELD QUALITY CONTROL WITH AOMPA�CT1� 57 FOR SBITE9`NORKAAND 95�EMAXIMUM DENSI Y NCE UNDER SLAB AREAS. AREAS OF SETTLEMENT WILL BE EXCAVATED AND REFILLED AT CONTRACTOR'S EXPENSE. 3.05 PROTECTION q, PROTECT SEEDED AREAS FORM EROSION BY SPREADW G STRAW TO A UNIFORM LOOSE DEPTH OF 1"-2'�. STAKE AND TIE DOWN AS AN�AICCEPT BLE �ALTER�NAITOIVECONTROL MESH OR MULCH NET SHALL BE B, ALL TIRES PLACED IN CONJUNCTION WITH A LANDSCAPE CONTRACT SHALL BE WRAPPED, TIED WITH HOSE PROTECTED WIRE AND SECURED TO STAKES EXTENDING 2'-0" INTO THE GROUND ON FOUR SIDES OF THE TREE. AND SOILL EROSIOND ST RAW SBALES BSHALL� BE PELDACED IATTTHE SN�ET 5 APPROACH TO ALL NEW OR EXISTING CULVERTS. CHAIN LINK FENCE PART 1 - GENERAL 4.01 SEQUENCING ELEVATIONHPRIORETORFENCE CONSTRUCTIONH FENCE POST EXCAV �TIONE SPOILS MUST BE CONTROLLED TO PRECLUDE CONTAMINATION OF SAID SURFACE COURSE. 4.02 APPLICABLE STANDARDS ASTM-A120 SPECIFICATION FOR PIPE, STEEL B�ACK AND HOT-DIPPED ZINC COATED (GALVANIZED) WELDED AND SEAMLESS FOR ORDINARY USES. ASTM-A123 ZWC (HOT-DIP GALVANIZED) COATING ON IRON AND STEEL PRODUCTS. ASTM-A525 STANDARD SPECIFICATION FOR STEEL SHEET ZINC COATED (GALVANIZED) BY THE HOT-DIPPED PROCESS. (q�NDRGATESECCHANTI0INK FENCEgFABRCCIAND AICCESSORI ��T METAL PART 2 - PRODUCTS 4.03 FENCE MATERIALS M ATERIALS SHALL BERHOTADIPPED GALVAN ZED RE AND OTHER STEEL g. FABRIC SHALL BE 8'-��� HIGH X 2° CHAIN LINK MESH OF N0. 9 GAUGE (OJ48) WIRE. THE FABRIC SHALL HAVE A TWISTED AND BARBED FINISH FOR THE TOP EDGES AND A KNUCKLED FINISH FOR THE BOTTOM EDGES, FABRIC SHALL CONFORM TO THE SPECIFICATIONS OF ASTM A-392 CLASS 1. WIRE, WAHBED GAUGE 4APONT ROUND BARBS �SPACEDAATE5T OISCED p, ALL POSTS SHALL BE SCHEDULE 20-GALVANIZED STEEL PIPE AND SHALL BE TYPE 1 ASTM A-123 AND OF THE FOLLOWING DIAMETER (OD PER FENCE INDUSTRY STANDARDS). LINE. 2 3�8 CORNER 3 GATE 3 TO PROV DEE D OR AT ACD M ORN OR B� RBED WIRIE.CLUDING DOME CAP, F, ALL TOP AND BRACED RAIL SHALL BE 1 5�8" DIAMETER SCHEDULE - 20 MECHANICAL - SERVICE PIPE. FRAMES SHALL HAVE �. GATE FRAMES SHALL HAVE A FULL-HEIGHT VERTICAL BRACE AND A FULL-WIDTH HORIZONTAL BRACE, SECURED IN PLACE BY USE OF GATE BRACE CLAMPS. ADAPTER WITHNMODELH6409gE 8EDEGREESAMTACHMEODE OR EQUALINGE �. THE GUIDE (LATCH ASSEMBLY) SHALL BE TAMPER PROOF- �, LATCHES, STOPS, AND KEEPERS SHALL BE PROVIDED FOR ALL GATES. K. ALL STOPS SHALL HAVE A FULL-HEIGHT PLUNGER BAR WITH DOME CAP. �. DOUBLE GATES SHALL HAVE A FULL-HEtGHT PLUNGER BAR WITH DOME CAP. M. A N0. 7 GAUGE ZINC COATED TENSION WIRE SHALL BE USED AT THE BOTTOM OF THE FABRIC, TERMINATED WITH BAND CLIPS AT CORNER AND GATE POSTS. N q 6" X 1/2" EYE-BOLT TO HOLD TENSION WIRE WILL 8E PLACED AT LINE POSTS. �. STRETCHER BARS SHALL BE 3/16" X 3/4" OR HAVE EQUIVALENT CROSS SECTIONAL AREA. p, ALL CORNER, GATE AND END PANELS SHALL HAVE A 3/8�� TRUSS ROD WITH TURNBUCKLES AND BE BRACED WITH ONE 1-5�8'� HORIZONTAL COMPRESSION MEMBER, SECURELY ATTACHED WITH IRON FITTINGS. CLIPS, BAOND CL PTS EAND A ENS ORN BAND �CILIPSBUT NOT LIMITED TO TIE S. BARBED WIRE GATE GUARDS SNALL BE FITTED WITH DOME CAPS. BOLT ANDgOCKIWRE�INPT�HE ARMS SHALL BE CAST IRON WITH SET �, ALL CAPS SHALL BE CAST STEEL. �. INSTALL REDWOOD SLATTING IN BETWEEN ALL FABRIC WIRE - FULL HT. PART 3 - EXECUTION 4.04 EQUIPMENT: EXCAVATE POST HOLES WITH MECHANICAL AUGER EQUIPMENT 4.05 INSPECTION: EXCAVATE POST HOLES PER CONSTRUCTION DOCUMENT CONFIRM PROPER DEPTH AND DIAMETER OF POST HOLE EXCAVATIONS. 4.06 INSTALLATION q. POST FOUNDATIONS SHALL HAVE A MINIMUM 6" CONCRETE COVER UNDER POST. g, ALL FENCE POSTS SHALL 8E VERTICALLY PLUMB WITHIN 1/4" IN 8'-���• �, AT CORNER POSTS, GATE POST AND SIDES OF GATE FRAME, FABRIC SHALL BE ATTACHED WITH STRETCHER AND TENSION BAND-CLIPS AT 1'-3" INTERVALS. p, AT LINE POSTS, FABRIC SHAI.L BE ATTACHED WITH BAND-CLIPS AT 1'-3'� WTERVALS. E. ATTACH FABRIC TO BRACE RAILS, TENSION WIRE AND TRUSS RODS WITH TIE CLIPS AT 2'-0" INTERVALS. UNK FABR C IAND THE FoINAL GRIADE. E PERMITTED BETWEEN THE CHAIN �, GATES SHALL BE INSTALLED SO LOCKS ARE ACCESSIBLE FROM BOTH SIDES. WELDED A 0 PREVENT UNAU HORIZEDVREMOVALTHREADS PEENED OR 4.p7 PROTECTION: UPON COMPLETION OF ERECTION, INSPECT FENCE MATERIAL AND PAINT FIELD CUTS OR GALVANIZING BREAKS WITH ZINC-BASED PAINT COLOR TO MATCH THE GALVANIZING PROCESS. CONCRETE CAST-IN-PLACE CONCRETE PART 1 - GENtKH� 1.01 DESCRIPTION WORK INCLUDES CONSTRUCTION OF CAST-IN-PLACE CONCRETE FOUNDATIONS, INCLUDING FURNISHWG AND WSTALLING READY-MIX CONCRETE, REWFORCING, FORMWORK, AND ACCESSORY MATERIALS AS SHOWN ON THE DRAWINGS. CAST-IN-PLACE CONCRETE WCLUDES ALL EIQUIPMENTRPADSNANDDIGUARDPODAT OUNDATAONSON GRADE, 1.0z RELATED WORK q, COORDINATE UNDER SLAB CONDUITS. g, COORDINATE WITH GROUNDING. 1.03 APPLICABLE STANDARDS q. ACI-301 - SPECIFICATIONS FOR STRUCTURAL CONCRETE BUILDINGS. g. ACI 347 - GUIDE TO FORMWORK FOR CONCRETE. �_ ASTM C33 - CONCRETE AGGREGATES. p, ASTM C94 - READY-MIXED CONCRETE. E, ASTM C150 - PORT�AND CEMENT. F, ASTM C260 - AIR-ENTRAINING ADMIXTURES FOR CONCRETE. COMPOUNDS FORgCURNQUICONCRERE.NE FORMING COMPOUNDS FORMING H, ASTM C494 - CHEMICAL ADMIXTURES FOR CONCRETE. �, ASTM A615 - STEEL WELDED WIRE FABRIC FOR CONCRETE REINFORCEMENT. �, ASTM A185 - STEEL WE�DED WIRE FABRIC FOR CONCRETE REINFORCEMENT. 1.04 QUAUTY ASSURANCE N�SPEC ED BYTTHIE ENGIN�EERPERATIONS SHALL BE TESTED AND 1.05 ItJTS CONCRETE MATERIALS AND OPERATIONS SHALL BE TESTED AND IDE ECT A�NBDEFECTIVEIWORK ORTMATERIA� SHA�LRNOTSN ANY WAYTO PREVENT LATER MATERIAL REJECTION WHEN SUCH DEFECT IS DISCOVERED NOR SHALL IT OBLIGATE THE ENGINEER FOR FINAL ACCEPTANCE. q, FIVE CONCRETE TEST CYLINDERS SHALL BE TAKEN OF THE TOWER AND PIER FOUNDATION. TWO SHALL BE TESTED � THREE DAYS, TWO � TWENTY-EIGHT DAYS. THE FIFTH CYLINDER SHALL BE KEPT SEPARATELY. IF REQUIRED TO BE USED IN THE FUTURE. g. ONE ADDITIONAL TEST CYLINDER SHA�L BE TAKEN DURING COLD WEATHER AND CURED ON SITE UNDER SAME CONDITIONS AS CONCRETE IT REPRESENTS. �, ONE SLUMP TEST SHALL BE TAKEN FOR EACH SET OF TEST CYLINDERS TAKEN. PART 2 - PRODUCT 2.01 CONCRETE MATERIALS CONCRETE SHALL 8E COMPOSED OF PORTLAND CEMENT. WATER, FWE AND COARSE AGGREGATES, AND ADMIXTURES AS SPECIFIED BELOW. ALL WELL MIXED AND BROUGHT TO PROPER CONSISTENCY. PORTLAND CEMENTMCONFORMINGBTOTASTMI C150Y COLOR, LOW-ALKALI CONCRETE SHADLLC�COMPLYAWTH ASTM.C33GftEGATES FOR USE IN �. WATER: WATER FOR MIXING AND CURING CONCRETE SHALL BE FREE FROM SEWAGE, OIL, ACID, ALKALI, AND SLATS AND SHALL BE FREE FORM OBJECTIONABLE QUANTITIES OF SILT, AND OTHER DE�ETERIOUS SUBSTANCES. Z,p2 ADMIXTURES q_ AIR ENTRAINMENT: AIR ENTRAINWG AGENT SHALL CONFORM TO ASTM C280. THE ADMIXTURE SHALL BE ADDED AS PART OF THE COMPUTED MIXING WATER REQUIREMENTS. AGENTS PREPARED IN gELgATOCH BY MEANSMOF RELIABLETMECHANIOCAL D SPE SERS.ND SHALL g. CHEMICAL ADMIXTURES: ASTM 494, TYPE A-N'ATER REDUCING AND RETARDING. 12875 East 42nd Avenue Suite 70 Denver, CO 80239 Office: 720374.1911 F a�c: 720.374.1890 D natek Y TELECOMMUNICATIONS SERVICES 7134 Brookwood Drive Brookfield, OH 44403 Phone:800-838-3224 Faac: 330-448-4337 www. dynatektelecom. com DYNATEK 6758 PROJ. NO.: DRAWNBY. S.R.M. CHECKEDBY�. D.C.B. I SUBMITTALS t 9/10/08 CODE REVIEW COMMENTS � 7/18/08 REDLINE REVISIONS 0 5/19/08 ISSUED FOR REVIEW THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY BY NATURER THA� USE OR DISCL � N THAT WHI LY NAME �@}w � r'^�� d �. �' �s;`'�:�� ;- 3��j� �`8 /� ! 9/z9/�� �� � ������� ������,: VAIL MIDDLE CREEK DEN-448B 145 N. �RONTAGE ROAD WEST VAIL, CO 81657 SHEET TITLE: GENERAL NOTES SHEET NUMBER: GN-2 F ' R 2.03 CURING COMPOUND: ASTM C309, TYPE 1, CLASS B; TRANSLUCENT. 2.04 ACCESSORIES A. NONSHRINK GROUT: PREMIXED COMPOUND CONSISTING OF NONMETALLIC AGGREGATE, CEMENT, WATER REDUCING AND PLASTICIZING AGENTS; CAPABLE OF DEVELOPING MINIMUM COMPRESSIVE STRENGTH OF 7,000 PSI IN 28 DAYS. B. JOINT FILLERS BITUMINOUS TYPE, ASTM D1751 OR NON-BITUMINOUS TYPE, ASTM D1752. C. ANCHOR BOLTS: ASTM A307. UNPRIMED. 2.05 CONCRETE MIX A. CONCRETE SHALL BE PROPORTIONED FOR WORKABILITY, MAXIMUM DENSITY, STRENGTH, AND DURABILITY REQUIREMENTS IN ACCORDANCE WITH ACI 301, THE 28-DAY DESIGN COMPRESSIVE STRENGTH OF CONCRETE SHALL BE AS SPECIFIED ON THE DRAWINGS. CONCRETE FURNISHED MAY BE A COMMERCIAL READY-MIX PROVIDED THAT DELIVERY TO THE PLACING LOCATION IS SATISFACTORILY ESTABLISHED AS OCCURRING NOT LATER THAN 45 MINUTES AFTER ADDITION OF WATER TO THE MIX. SLUMP OF DELNERED CONCRETE SHALL NOT EXCEED 5". B. THE FOLLOWING STRENGTHS SHALL BE USED: 1. FENCE POSTS FOUNDATIONS - DESIGN COMPRESSIVE STRENGTH AT 28 DAYS OF 2,000 PSI. 2. EQUIPMENT FOUNDATIONS - DESIGN COMPRESSIVE STRENGTH AT 28 DAYS OF 4,000 P51. 3. ALL OTHER CONCRETE NOT SPECIFIED - DESIGN COMPRESSIVE STRENGTH AT 28 DAYS OF 3,000 P51. 4. CONCRETE SPECIFICATION FOR MONOPOLE OR TOWER FOUNDATION SHALL CONFORM TO MANUFACTURER'S RECOMMENDATIONS. C. USE ACCELERATING ADMIXTURES IN COLD WEATHER ONLY WHEN APPROVED BY THE ENGWEER. USE OF ADMIXTURES WILL NOT RELAX COLD WEATHER PLACEMENT REQUIREMENTS. D. USE SET-RETARDING ADMIXTURES DURING HOT WEATHER ONLY WHEN APPROVED BY THE ENGINEER. E. ADD AIR ENTRAINING AGENT TO CONCRETE MIX FOR CONCRETE WORK SUBJECT TO OR EXPOSED TO EXTERIOR. PART 3 - EXECUTION 3.01 INSPECTION THE CONTRACTOR SHALL VERIFY ANCHORS, SEATS, PENETRATIONS, PLATES, REINFORCEMENT, AND OTHER ITEMS TO BE CAST INTO CONCRETE ARE ACCURATELY PLACED, HELD SECURELY, AND SHALL NOT CAUSE HARDSHIP IN PLACING CONCRETE. 3.02 PREPARATION A. THE CONTRACTOR SHALL PREPARE PREVIOUSLY PLACED CONCRETE BY CLEANING WITH STEEL BRUSH AND APPLYING BONDING AGENT. APPLY BONDING AGENT IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. 3.03 PLACING CONCRETE A. THE ENGINEER SHALL BE NOTIFIED NOT LESS THAN 24 HOURS IN ADVANCE OF CONCRETE PLACEMENT. UNLESS INSPECTION IS WAIVED IN EACH CASE, PLACING OF CONCRETE SHALL BE PERFORMED ONLY IN THE PRESENCE OF THE ENGINEER. CONCRETE SHALL NOT BE PLACED UNTIL ALL FORMWORK, EMBEDDED PARTS, STEEL REINFORCEMENT, FOUNDATION SURFACES, AND JOINTS INVOLVED IN THE PLACING HAVE BEEN APPROVED, AND UNTIL FACILITIES ACCEPTABLE TO THE CRICKET REPRESENTATIVE HAVE BEEN PROVIDED AND MADE READY FOR ACCOMPLISHMENT OF THE WORK AS SPECIFIED. CONCRETE MAY NOT BE ORDERED FOR PLACEMENT UNTIL ALL ITEMS HAVE BEEN APPROVED AND CRICKET HAS PERFORMED A FINAL INSPECTION AND GIVEN APPROVAL TO START PLACEMENT TESTING. B. PLACEMENT OF CONCRETE SHALL BE IN ACCORDANCE WITH ACI 301. C. THE CONTRACTOR SHALL ENSURE THAT REINFORCEMENT, INSERTS, EMBEDDED PARTS, FORMED JOINTS, AND VAPOR BARRIERS ARE NOT DISTURBED DURING CONCRETE PLACEMENT. 3.04 SURFACE FINISHES A. SURFACES AGAINST WHICH BACKFILL OR CONCRETE SHALL BE PLACED REQUIRE NO TREATMENT EXCEPT REPAIR OF DEFECTIVE AREAS. B. SURFACES THAT WILL BE PERMANENTLY EXPOSED SHA�L PRESENT A UMFORM FINISH PROVIDED BY THE REMOVAL OF FINS AND THE FILLING OF HOLES AND OTHER IRREGULARITIES WITH DRY PACK GROUT, OR BY SACKING WITH UTIUTY OR ORDINARY GROUT. C. SURFACES THAT WOULD NORMALLY BE LEVEL AND WHICH WILL BE PERMANENTLY EXPOSE TO THE WEATHER SHALL BE SLOPED FOR DRAINAGE. UNLESS ENGINEER'S DESIGN DRAWING SPECIFIES A HORIZONTAL SURFACE OF SURFACES, SUCH AS STAIR THREADS, WALLS, CURBS, AND PARAPETS SHALL BE S�OPED APPROXIMATELY 1/4 FT. D. SURFACES THAT WILL BE COVERED BY BACKFILL OR CONCRETE SHALL BE SMOOTH SCREENED. E. EXPOSED SLAB SURFACES SHALL BE CONSOLIDATED, SCREENED, FLOATED, AND STEEL TROWELED. HAND OR POWER-DRIVEN EQUIPMENT MAY BE USED FOR FLOATING SHALL BE STARTED AS SOON AS THE SCREENED SURFACE HAS ATTAINED A STIFFNESS TO PERMIT FINISHING OPERATIONS. FLOATING SHALL BE CONTINUED THE MINIMUM TIME REQUIRED TO PRODUCE A SURFACE UNIFORM IN TEXTURE AND FREE FROM SCREENED MARKS OR OTHER IMPERFECTIONS. THE FINAL FINISH SHALL BE PRODUCED BY USE OF STEEL-BLADED FINISHING TROWELS. STEEL TROWLING SHALL COMMENCE ONLY AFTER THE SURFACES TO BE FINISHED HAVE BEEN BROUGHT TO CORRECT ELEVATION AND ALL SURFACE IMPERFECTIONS CORRECTED, AND SHALL BE CONTINUED ONLY UNTIL THE SURFACE IS SMOOTH AND UNIFORM IN TEXTURE AND APPEARANCE. IF FREE WATER IS BROUGHT TO THE SURFACE DURING THE FINISHING OPERATIONS, IT SHALL BE REMOVED BY SPONGING. FINISHING SHA�L BE TIMED AND PERFORMED SO THAT EXTRA WATER NEED NOT BE APPLIED TO THE SURFACE BEING TROWE�ED. 3.05 PATCHING THE CONTRACTOR SHALL NOTIFY THE ENGINEER IMMEDIATELY UPON REMOVAL OF THE FORMS TO OBSERVE CONCRETE SURFACE CONDITIONS. IMPERFECTIONS SHALL BE PATCHED ACCORDING TO THE ENGINEER'S DIRECTION. 3.06 DEFECTIVE CONCRETE THE CONTRACTOR SHALL NOTIFY OR REPLACE CONCRETE NOT CONFORMING TO REQUIRED LEVELS AND LINES, DETAILS, AND ELEVATIONS AS SPECIFIED IN ACI 301. 3.07 PROTECTION A. IMMEDIATELY AFTER PLACEMENT. THE CONTRACTOR SHALL PROTECT THE CONCRETE FROM PREMATURE DRYING, EXCESSIVELY HOT OR COLD TEMPERATURES, AND MECHANICAL INJURY. FINISHED WORK SHALL BE PROTECTED. B. CONCRETE SHALL BE MAINTAINED WITH MINIMAL MOISTURE LOSS AT RELATIVELY CONSTANT TEMPERATURE FOR PERIOD NECESSARY FOR HYDRATION OF CEMENT AND HARDENING OF CONCRETE. C. ALL CONCRETE SHALL BE WATER CURED BY CONTINUOUS (NOT PERIODIC) FINE MIST SPRAYING OR SPRINKLING ALL EXPOSED SURFACES. WATER SHALL BE CLEAN AND FREE FROM ACID, ALKALI, SLATS, OIL, SEDIMENT, OR ORGANIC MATTER. SUCCESSFUL CURING SHALL BE ASSURED BY USE OF AN AMPLE WATER SUPPLY UNDER PRESSURE IN PIPES. WITH ALL NECESSARY APPLIANCES OF HOSE, SPRINKLERS, AND SPRAYING DEVICES. METALS PART 1 - GENERAL 1.01 WORK INCLUDED A. THE WORK CONSISTS OF THE FABRICATION AND INSTALLATION OF ALL MATERIALS TO BE FURNISHED, AND WITHOUT LIMITING THE GENERALITY THEREOF, INCLUDES ALL EQUIPMENT, LABOR AND SERVICES REQUIRED FOR ALL STRUCTURAL STEEL WORK INCLUDING ALL ITEMS INCIDENTAL THERETO AS SPECIFIED HEREIN AND AS SHOWN ON THE DRAWINGS. INCLUDING: 1. STEEL FRAMING INCLUDING BEAMS, ANGLES, CHANNELS AND PLATES. 2. WELDING AND BOLTING OF ATTACHMENTS. 1.02 REFERENCE STANDARDS A. THE WORK SHALL CONFORM TO THE CODES AND STANDARDS OF THE FOLLOWING AGENCIES AS FURTHER SIGHTED HEREIN: 1. ASTM: AMERICAN SOCIETY FOR TESTING AND MATERIALS, 196 RACE STREET, PHILADELPHIA, PA 19103, USA AS PUBLISHED IN °COMPILATION OF ASTM STANDARDS IN BUILDING CODES". 2. AWS: AMERICAN WELDING SOCIETY INC., 2501 NW 7TH STREET, MIAMI, F� 33125 USA AS PUBLISHED IN "CODE FOR STANDARD PRACTICE FOR STEEL BUILDINGS AND BRIDGES": "SPECIFICATIONS FOR THE DESIGN, FABRICATION AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS." PART 2 - PRODUCTS 2.01 MATERIALS A. STRUCTURAL STEEL SHALL COMPLY WITH THE REQUIREMENTS OF ASTM A36 AND A50 FOR STRUCTURAL STEEL. 2.02 WELDING A. ALL WELDWG SHALL BE DONE BY CERTIFIED WELDERS. CERTIFICATION DOCUMENTS SHALL BE MADE AVAI�ABLE FOR ENGINEER'S AND/OR OWNER'S REVIEW IF REQUESTED. B. WELDING ELECTRODES FOR MANUAL SHIELDED METAL ARC WELDING SHALL CONFORM TO ASTM 1-233, E70 SERIES. BARE ELECTRODES AND GRANULAR FLUX USED IN THE SUBMERGED ARC PROCESS SHALL CONFORM TO AISC SPECIFICATIONS. C. FIELD WELDWG SHALL BE DONE AS PER AWSD1.1 REQUIREMENTS VISUAL INSPECTION IS ACCEPTABLE. D. STUD WELDING SHALL BE ACCOMPLISHED BY CAPACITOR DISCHARGE (CD) WELDWG TECHNIQUE USING MIDWEST FASTENERS, INC. CD100 CAPACITOR DISCHARGE STUD WELDER OR EQUAL. 2.2 PROVIDE STUD FASTENERS OF MATERIALS AND SIZES SHOWN ON DRAWINGS OR AS RECOMMENDED BY THE MANUFACTURER FOR STRUCTURAL LOADINGS REQUIRED. 2.3 FOLLOW MANUFACTURERS SPECIFICATIONS AND WSTRUCTIONS TO PROPERLY SELECT AND INSTALL STUD WELDS. 2.03 BOLTING A. BOLTS SHALL BE 3/4" (MINIMUM) CONFORMING TO ASTM A325, HOT DIP GALVANIZED OR ASTM A153, NUTS SHALL BE HEAVY HEX TYPE. B. ALL BOLTS SHALL BE INSTALLED IN SLIP CRITICAL CONNECTIONS CONFORMING TO AISC METHOD, CONFORMING TO THE 1/4 TURN METHOD. 2.04 FABRICATION A. FABRICATION OF STEEL SHALL CONFORM TO THE AISC AND AWS STANDARDS AND CODES. 2.05 FINISH A. STRUCTURAL STEEL EXPOSED TO WEATHER SHALL BE HOT-DIP GALVANIZED AFTER FABRICATION IN ACCORDANCE WITH ASTM A123. 2.06 PROTECTION A. UPON COMPLETION OF ERECTION INSPECT ALL GALVANIZED STEEL AND PAINT ANY FIELD CUTS, WELDS, OR GALVANIZED BREAKS WITH ZINC BASED PAINT. COLOR TO MATCH THE GALVANIZING PROCESS. 3.01 ERECTION OF STEEL A. PROVIDE ALL ERECTION EQUIPMENT, BRACING, PLANKING, FIELD BOLTS, NUTS, WASHERS, DRIFT PINS, AND SIMILAR MATERIALS WHICH DO NOT FORM A PART OF THE COMPLETED CONSTRUCTION, BUT ARE NECESSARY FOR ITS PROPER ERECTION. 8. ERECT AND ANCHOR ALL STRUCTURAL STEELIN ACCORDANCE WITH AISC REFERENCE STANDARDS. ALL WORK SHALL BE ACCURATELY SET TO ESTABLISHED ATTACHMENTS TO THE CONSTRUCTION OF THE BUILDING. C. TEMPORARY BRACING, GUYING, AND SUPPORT SHALL BE PROVIDED TO KEEP THE STRUCTURE SET AND ALIGNED AT ALL TIMES DURING CONSTRUCTION, AND TO PREVENT DANGER TO PERSONS AND PROPERTY. CHECK ALL TEMPORARY LOADS AND STAY WITHIN SAFE CAPACITY OF ALL BUILDING COMPONENTS. SPECIAL CONSTRUCTION ANTENNA INSTALLATION PART 1 - GENERAL 1.01 WORK INCLUDED A. ANTENNAS AND COAXIAL CABLES ARE FURNISHED BY CRICKET UNDER SEPARATE CONTRACT. THE CONTRACTOR SHALL ASSIST ANTENNA WSTALLATION CONTRACTOR W TERMS OF COORDINATION AND SITE ACCESS. ERECTION SUBCONTRACTOR SHALL BE RESPONSIBLE FOR THE PROPERTY. B. INSTALL ANTENNAS AS INDICATED ON DRAWINGS AND CRICKET COM. SPECIFICATIONS. C. INSTALL GALVANIZED STEEL ANTENNA MOUNTS AS INDICATED ON DRAWINGS. D. INSTALL FURNISHED GALVANIZED STEEL OR ALUMINUM WAVEGUIDE AS INDICATED ON DRAWINGS. 12875 East 42nd Avenue Suite 70 Denver, CO 80239 Office: 720.374.1911 Fax: 720.374.1890 D natek Y TELECOMMUNICATIONS SERVICES 7134 Brookwood Drive Brookfield, OH 44403 Phone: 800-838-3224. Fa�c: 330-448-4337 www. dy natektelecom. com DYNATEK 6758 PROJ. NO.: DRAWN BY: S.R.M. CHECKEDBY: D.C.B. SUBMITTALS 2 9/10/08 CODE REVIEW COMMENTS I 7/IB/08 REDLINE REVISIONS 0 5/19/08 ISSUED FOR REVIEW THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THA� THAT WHICH IEN7 NAME IS � �,��s " � �%��- p;����� i;, � ����f,�� r �€r��'�� ��c� 9 z 9/0� . ``���`�' �','1 a ; 9 t''�'`�� VAIL MIDDLE CREEK DEN-448B !45 N. FRONTAGE ROAD WEST VAIL, CO 8!657 SHEET TITLE: GENERAL NOTES SHEET NUMBER: GN-3 '�� / . ' � 0 E. CONTRACTOR SHALL PROVIDE FOUR (4) SETS OF SWEEP TEST UNDER HEW�ETT—PACKARD 8713B RF SCALAR NETWORK ANALYZER. SUBMIT FREQUENCY DOMAIN REFLECTOMETER (FDR) TEST RESULTS TO INDEP NDENT ESTNGESERVCEIAND BELBO NDEANDRSUBMIBTTEDNWITHIN ONE WEEK OF WORK COMPLETION. F. INSTALL COAXIAL CABLES AND TERMINATIONS BETWEEN ANTENNAS AND EQUIPMENT PER MANUFACTURER'S RECOMMENDATIONS. WEATHERPROOF ALL CONNECTORS BETWEEN THE ANTENNA AND EQUIPMENT PER MANUFACTURER'S REQUIREMENTS. TERMINATE ALL COAXIAL CABLE THREE (3) FEETIN EXCESS OF ENTRY PORT LOCATION UNLESS OTHERWISE STATED. G. ANTENNA AND COAXIAL CABLE GROUNDING: 1. ALL EXTERIOR #6 GREEN GROUND WIRE DAISY CHAIN CONNECTIONS ARE TO BE WEATHER SEALED WITH ANDREWS CONNECTOR/SPLICE WEATHERPROOFING KIT TYPE 3221213 OR EQUIVALENT. INSTAL ED ONAST AOGHT RU SB OF COAXIAL CABLE (N T WITB N BENDS). 1.02 RELATED WORK FURNISH THE FOLLOWING WORK AS SPECIFIED UNDER CONSTRUCTION DOCUMENTS, BUT COORDINATE WITH OTHER TRADES PRIOR TO BID: 1. FLASHING OF OPENING INTO OUTSIDE WALLS. 2. SEALING AND CAULKING ALL OPENINGS. 3. PAINTING. 4 CUTTING AND PATCHING. 1.03 REQUIREMENTS OF REGULATOR AGENCIES A. FURNISH U.L LISTED EQUIPMENT WHERE SUCH LABEL IS AVAILABLE. INSTALL IN CONFORMANCE WITH U.L STANDARDS WHERE APPUCABLE. B. INSTALL ANTENNA, ANTENNA CABLES, GROUNDING SYSTEM IN ACCORDANCE WITH DRAWINGS AND SPECIFICATIONS IN EFFECT AT PROJECT LOCATION AND RECOMMENDATIONS OF STATE AND LOCAL BUILDING CODES HAVING JURISDICTION OVER SPECIFIC PORTIONS OF WORK. THIS WORK INCLUDES, BUT IS N07 LIMITED TO THE FOLLOWING: STRUCTURAL S ANDARDSTFORISTEEL ANTENNA TOWERS� AND NTENNA SUPPORTING STRUCTURES. 2. FAA — FEDERAL AVIATION ADMINISTRATION ADVISORY CIRCULAR AC 70/7480—IH, CONSTRUCTION MARKING AND LIGHTING. 3. FCC — FEDERAL COMMUNICATION COMMISSION RULES AND REGULATIONS FORM 715, OBSTRUCTION MARKING AND LIGHTING SPECIFICATION FOR ANTENNA STRUCTURES 4. AISC — AMERICAN INSTITUTE OF STEEL CONSTRUCTION FOR STRUCTURAL JOINTS USING ASTM 1325 OR A490 BOLTS. 5. NEC — NATIONAL ELECTRIC CODE — ON TOWER LIGHTING KITS. 6. UL — UNDERWRITER'S LABORATORIES APPROVED ELECTRICAL PRODUCTS. 77 AND722 OF HE� CC RULES ARE7APPLIC BLE A DUINSTHEDEVENTS OF CONFLICT, SUPERSEDE ANY OTHER STANDARDS OR SPECIFICATIONS 8. LIFE SAFETY CODE NFPA, LATEST EDITION. ELECTRICAL SPECIFICATIONS GENERAL PROPERTIES A. REQUIREMENTS: FURNISH ALL LABOR, MATERIALS, SERVICE, EQUIPMENT, AND APPLIANCES REQUIRED TO COMPLETE THE INSTALLATION OF THE COMPLETE ELECTRICAL SYSTEM IN ACCORDANCE WITH THE SPECIFICATIONS AND CONTRACT DRAWINGS. B. REQUIREMENTS OF REGULATORY AGENCIES AND STANDARDS: INSTALLATION, MATERIAL, EQUIPMENT AND WORKMANSHIP SHALL CONFORM TO THE APPLICABLE PROVISIONS OF THE NATIONAL ELECTRIC CODE (NEC) — APPLICABLE STATE ELECTRIC CODES, THE NATIONAL ELECTRICAL SAFETY CODES (NESC), AND THE TERMS AND THE CONDITIONS OF THE AUTHORITIES HAVING LAWFUL JURISDICTION PERTAINING TO THE WORK REQUIRED. ALL MODIFICATIONS REQUIRED BY THESE CODES, RULES, REGULATIONS, AND AUTHORITIES SHALL BE MADE BY THE CONTRACTOR WITHOUT ADDITIONAL CHARGE TO THE UNDERWRITER'S LABORATORIES (UL): A�L MATERIALS, APPLIANCES, OR DEVICES SHALL CONFORM TO THE APPLICABLE STANDARDS OF UNDERWRITER'S LABORATORIES, INC. THE LABEL OF, OR LISTING BY: U.L IS REQUIRED. �• MATERIALS: ALL SIMILAR MATERIALS AND EQUIPMENT SHALL BE MATERRODAPPARATUS ORMAPPLIANCECISUMENTO ED. NMANU AC URER MAY BE USED PROVIDING IT CONFORMS TO THE CONTRACT REQUIREMENTS AND MEETS THE APPROVAL OF THE OWNER. MATERIAL AND EQUIPMENT SHALL BE THE STANDARD PRODUCTS OF MANUFACTURER'S REGULARLY ENGAGED IN THE PRODUCTIONS OF SUCH MATERIAL AND SHALL BE THE MANUFACTURER'S CURRENTIN STANDARD AND DESIGN. � EXECUTION: FABRICATION, ERECTION, AND INSTALLATION OF THE COMPLETE ELECTRICAL SYSTEM SHALL BE DONE IN A FIRST CLASS WORKMANLIKE MANNER BY QUALIFIED PERSONNEL EXPERIENCED IN SUCH WORK AND SHALL PROCEED IN AN ORDERLY MANNER SO AS NOT TO HOLD UP PROGRESS OF THE PROJECT. E• PERFORMANCE TESTS: THOROUGHLY TEST FEEDERS, EQUIPMENT AND ALL CIRCUITS FOR PROPER OPERATING CONDITION AND FREEDOM FROM GROUNDS AND SHORT CIRCUITS BEFORE ACCEPTANCE IS REQUESTED. ALL EQUIPMENT, APPLIANCES, AND DEVICES SHALL BE OPERATED UNDER LOAD CONDITIONS. F. AS—BUILT DRAWINGS: DURING PROCESS OF THE WORK, MAINTAIN AN ACCURATE RECORD OF THE INSTALLATION OF THE SYSTEM, LOCATING EACH CIRCUIT PRECISELY BY DIMENSION. UPON COMPLETION OF THE INSTALLATION, TRANSFER ALL RECORD DATA TO BLUE LINE PRINTS OF THE ORIGINAL DRAWINGS. RACEWAYS, BOXES, AND FITTINGS A. CONDUITS, ELECTRICAL, METALLIC TUBING (MET): MILD STEEL, ZINC COATED ON THE OUTSIDE AND EITHER ZINC COATED OR COATED WITH AN APPROVED CORROSION RESISTANT COATING ON THE INSIDE. MAXIMUM. SIZE 2 ELECTRICAL TRADE SIZE UNLESS NOTED ON THE DRAWINGS OR SPECIFICALLY APPROVED FOR EQUIPMENT CONNECTIONS. SIZES NOT NOTED ON DRAWINGS SHALL BE AS REQUIRED BY NEC. COUPLN�GS ANDFCO NECTORS EITHER STEEL ORUMALLEABLE IRON ONLY. CONCRETE TIGHT OR RAIN TIGHT AND EITHER THE GLAND AND RING COMPRESSION TYPE OR THE STAINLESS STEEL MULTIPLE LOCKING TYPE, CONNECTORS TO HAVE INSULATED THROATS, EMT FITTINGS USWG SET SCREWS OR INDENTATIONS AS A MEANS OF ATTACHMENT ARE NOT TO BE PERMITTED. BUSHINGS: INSULATED TYPE, DESIGNED TO PREVENT ABRASION OF WIRES WITHOUT IMPAIRING THE CONTINUITY OF THE CONDUIT, IMC AND RIGID ALUMINUM CONDUIT. C. CONDUIT INSTALLATIONS: CONDUITS SYSTEMS, EMT, OR RIGID NONMETALLIC CONDUIT UNLESS NOTED. CONDUIT INSTALLATION: INSTALL CONCEALED CONDUIT AND EMT IN AS DIRECT LWES AS POSSIBLE INSTALL EXPOSED CONDUITS AND EMT PARALLEL TO OR AT RIGHT ANGLES TO THE LINES OF THE BUILDING. RIGHT ANGLE BENDS IN EXPOSED CONDUIT AND EMT RUNS SHALL BE MADE WITH STANDARD ELBOWS, SCREW JOINTED CONDUIT FITTINGS OR CONDUIT BENT TO RADIUS NO LESS THAN THOSE OF STANDARD ELBOWS. D. CONDUIT SUPPORTS: PROVIDE SUPPORTS FOR HORIZONTAL CONDUITS AND EMT NOT MORE THAN 8 FEET APART WITH NOT LE55 THAN TWO ELBOW OR BEND INCLUDING RUNS ABOVE SUSPENDED FITITINGS, ETC. WINSTALL ONE �OLDLPIPENSTR� PS ONE CONDU TSES INCH OR SMALLER INSTALL INDIVIDUAL PIPE HANGERS FOR CONDUITS LARGER THAN 1 INCH. SPRING STEEL FASTENERS WITH HANGER RODS MAY BE USED IN DRY LOCATIONS IN LIEU OF PIPE STRAPS. CONDUCTORS A. WIRES AND CABLES (600 VOLTS): CONFORM TO THE APPLICABLE UL AND IPCEA STANDARDS FOR THE USE INTENDED. COPPER CONDUCTORS WITH 600 VOLTS WSULATION UNLESS OTHERWISE SPECIFIED OR NOTED ON THE DRAWINGS. STRANDED CONDUCTORS FOR N0. 8 OR LARGER WHERE ELSEWHERE SPECIFIED OR NOTED ON THE DRAWINGS. USE OF ALUMINUM CONDUCTORS WILL NOT BE PERMITTED. INSULATION SHALL BE TYPE THHN/THWN INSULATION 75' C FOR ALL A�CORDA�CE WITHENEC.E CONNIECT�AL�LNCONDUCTOR�SL�R TODESAME PHASE CONDUCTOR, COLOR CODING SHALL BE A—BLACK, B—RED, N—WH17E, WITH GREEN FOR ALL GROUND CONDUCTORS. B. CONNECTORS AND LUGS: FOR COPPER CONDUCTORS N0. 6 AND SMALLER: 3M SCOTCH—LOK OR T& B STA—KON COMPRESS�ON OR INDENT TYPE CONNECTORS WITH INTEGRAL OR SEPARATE INSULATING CAPS. FOR COPPER CONDUCTORS LARGER THAN N0. 6 SOLDERLESS, INDENT HEX SCREW OR BOLT TYPE PRESSURE CONDUCTORS, PROPERLY TAPED OR INSULATED. C. SPLICES: (480 VOLTS AND UNDER): CONDUCTOR LENGTHS SHALL BE CONTINUOUS FROM TERMINATION TO TERMINATION WITHOUT SPLICES UNLESS APPROVED BY THE BUILDING WSPECTOR. CIRCUIT BREAKERS A. PROVIDE MOLDED CASE, BOLT—ON, THERMAL MAGNETIC TRIP, SINGLE, TWO. OR THREE POLE BRANCH CIRCUIT BREAKERS AS SHOWN ON DRAWINGS. MULTIPLE POLE BREAKERS SHALL BE SING�E HANDLE, COMMON TRIP, A�C RATING TO MATCH EXISTING OR AS REQUIRED FOR AVAILABLE FAULT CURRENTS. GROUNDING A. ALL ELECTRICAL AND GROUNDING AT THE CELL SITE SHALL COMPLY WITH THE NATIONAL ELECTRICAL CODE (NEC), NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) 780 (LATEST EDITION), AND MANUFACTURER. B. IF THE AC PANEL IN THE POWER CABINET IS WIRED AS SERVICE ENTRANCE, THE AC SERVICE GROUND CONDUCTOR SHALL BE CONNECTED TO GROUND ELECTRODE SYSTEM. WHEN THE AC PANELIN THE POWER CABINET IS CONSIDERED A SUB—PANEL, THE GROUND WIRE SHALL BE INSTALLED IN THE AC POWER CONDUIT. THE INSTALLATION SHALL BE PER LOCAL AND NATIONAL ELECTRIC CODE (NFPA-7p�, C. EXOTHERMIC WELDING IS RECOMMENDED FOR GROUNDING CONNECTION WHERE PRACTICAL OTHERWISE, THE CONNECTION SHALL BE MADE USING COMPRESSION TYPE-2 HOLES. LONG BARREL LUGS OR DOUBLE CRIMP CLAMP "C" CLAMP. THE COPPER CABLES SHALL BE COATED WITH ANTIOXIDANT (COPPER SHIELD) BEFORE MAKING THE RECOMM � DATIONS ON THE BOLT A SEMBRY TO S�ECU E CONNECTIONS ARE TO BE FOLLOWED. D. THE ANTENNA CABLES SHALL BE GROUNDED AT THE TOP AND BOTTOM OF THE VERTICAL RUN FOR LIGHTING PROTECTION. THE ANTENNA CABLE SHIELD SHALL BE BONDED TO A COPPER GROUND BUS AT THE LOWERMOST POINT OF A VERTICAL RUN JUST BEFORE IT BEGINS TO BEND TOWARD THE HORIZONTAL PLANE. WIRE RUNS TO GROUND SHALL BE KEPT AS STRAIGHT AND SHORT AS POSSIBLE. THE ANTENNA CABLE SHIELD SHALL BE GROUNDED JUST BEFORE ENTERING THE CE�L CABINET. ANY ANTENNA CABLES OVER 200 FEET IN LENGTH SHALL ALSO BE EQUIPPED WITH ADDITIONAL GROUNDING AT MID—POINT. 6. ALL GROUNDING CONDUCTORS INSIDE THE BUILDING SHALL BE RUN IN CONDUIT RACEWAY SYSTEM, AND SHALL BE INSTALLED AS STRAIGHT AS PRACTICAL WITH MINOR BENDS TO AVOID OBSTRUCTIONS. THE MINIMUM BENDING RADIUS OF ANY #2 GROUNDING CONDUCTOR IS 8��. PVC RACEWAY MAY BE FLEXBLE OR RIGID PER THE FIELD CONDITIONS. GROUNDING CONDUCTORS SHALL NOT MAKE CONTACT WITH ANY METALLIC CONDUITS, SURFACES, OR EQUIPMENT. 7. PROVIDE PVC SLEEVES WHERE GROUNDING CONDUCTORS PASS THROUGH THE BUILDING WALLS AND/OR CEILINGS. 8. INSTALL GROUND BUSHINGS ON ALL METALLIC CONDUITS AND BOND TO THE EQUIPMENT GROUND BUS IN THE PANElBOARD. g. GROUND ANTENNA BASES, FRAMES, CABLE RACKS, AND OTHER METALLIC COMPONENTS WITH #Z GROUNDW G CONDUCTORS AND CONNECT TO INSULATED SURFACE MOUNTED GROUND BARS. CONNECTION DETAILS SHALL FOLLOW MANUFACTURER'S SPECIFICATIONS FOR GROUNDING. 10. GROUND COAXIAL SHIELD AT BOTH ENDS USING MANUFACTURER'S GUIDELINES. 11. GROUND FIELD TEST PROCEDURE THE CONTRACTOR SHALL BE RESPONSIBLE TO PROVIDE A"FALL OF POTENTIAL" TEST ON THE NEW SUPPLEMENTAL GROUND FIELD PRIOR TO FINAL CONNECTION OF THE GROUNDING SYSTEM TO EQUIPMENT. THE TEST SHALL BE PERFORMED BY A QUALIFIED AND CERTIFIED TESTING AGENT. PROVIDE INDEPENDENT TEST RESULTS TO THE PROJECT MANAGER FOR REVIEW. THE GROUND SYSTEM RESISTANCE TO EARTH GROUND SHALL NOT EXCEED TEN (10) OHMS. IF THE GROUND TEST EXCEEDS THE MAXIMUM OF 10 OHMS, THE CONTRACTOR SHALL BE RESPONSIBLE TO PROVIDE ADDITIONAL GROUND CONNECTIONS AS REQUIRED TO MEET THE 10 OHMS MAXIMUM. 12875 East 42nd Avenue Suite 70 Denver, CO 80239 Office: 720.374.19ll Faac: 720.374. I 890 D natek Y TELECOMMIJNICATIONS SERVICES 7134 Brookwood Drive Brookfield, OH 44403 Phone:800-838-3224 Fax:330-448-4337 www. dynatektel ecom. com DYNATEK PROJ. NO.: 6758 DRAWNBY: S.R.M. I CHECKEDBY; D.C.B. SUBMITTALS 2 9/10/OB CODE REVIEW COMMENTS I 7/18/08 REDLINE REVISIONS 0 5/19/08 ISSUED FOR REVIEW THE INFORMATION CONTAINED IN PROPIRIETAR� BY� ATURE.S ANY USE OR DISCLO R THAN THAT WHI �FNT NAME I LT�°v PRnt,u T: `\ � ��vi{� �. � �f��R:�+L� � �G��i°8 ° � q/2 �/Gv A .� �� ,` \ —``=` �'a ,APi�,�' VAIL MIDDLE CREEK DEN-448B 145 N. FRONTAGE ROAD WEST VAIL, CO 81657 SHEET TITLE: GENERAL NOTES SHEET NUMBER: GN-4 /: � � �# . c r-�"������^` (� EXISTING BUILDING: � OCCUPANCY: R-2 ( SPRINKLED: YES ( CONST TYPE: VA \ PROPOSED BUILDING: OCCUPANCY: U SPRINKLED: NO CONST 7YPE: VB HEIGHT: ! STORY ARcA: 262 54. FT. ,LLOWABLE HEIGHTS & AREAS: (2006 BC TABLE 503) CONST TYPE: VB MAX. HEIGHT: I STORY MAX. AREA: 5,500 SQ. FT. � ���-����� � H�v�.� RATING REQUIREMENTS FOR EXTERIOR WALL BASED ON FIRE SEPERATION DISTANCE: `, (2006 IBC TABLE 602) � �•V`. �'� DISTANCE: 10' < X < 30' CONST TYPE (EXISTING): VA f CONST TYPE (PROPOSED): VB i � OCCUPANCY GROUP: R& U � � FIRE-RESISTANCE RATING: I HR i 1 � BUILD4NG INFORMATION '� � � U.�N4 �-''S S►iA�-�- �.'F"t�.M -ro 'T��1�- i+ov,�A'��cN ow sn�rr�+ � �►sT +�rty- S P� 1�L '�AY� :.rL � � / �� � / DYNATEK TELECOMMUNICATIONS SERVICES 7134 BROOKWOOD DRIVE BROOKFIELD, OH 44403 PHONE: 800.830.3224 FAX: 330.448.4337 CONTACT: MARK THOMPSON BUILDING OWNER: TowN oF vni� ADDRESS: IL5 S FRONTAGE ROAD VAIL, CO 81657 PHONE: 970.479.2154 FAX: 970.479.2248 CON7ACT: RON BRADEN (DIRECTOR) APPLICANT: CRICKET COMMUNICA710N5 12875 EAST 42ND AVENUE, SUITE 70 DENVER, CO 80239 OFFICE: 720.374.191I FAX: 720.374.1890 ELECTRIC HOLY CROSS ENERGY TELCO QWES7 CONSULTANT TEAM VAIL MIDDLE CRE�K CRICKET SITE NUMBER: DEN-448-8 SITE ADDRESS: 145 N. FRONTAGE ROAD VAIL, CO 81657 JURISDICTION: EAGLE COUNTY LAr. 39° 38' 45.599992" N LoNC.106° 22' S0.799972" W TOi�1V ��y ����. �s: , ,� � e� : i�; � � � communication s APPR�V�� i Community Development D��artment � Buiidin� Safety and jnspecti� Services �05. � � SITE NAME: `��� ��� ���g �ntemational Building Code 9��i/� �n � M I D D L E C R E E K � 3�x Code alidit of °' Y p�m�it The issuance or rarrti not be nstrued to be a permit for, or an approval of, ar,� r ;� anY of t e provisions of this code � pf a�y ��r ordinanoe w._,� junsdict on. Permits presuming to give authar�•ty tp ���fe � p��i � provisio s of this code or other ordinances of t he jurisdictio�t shay not b� S I T E N U M B E R: valid. T e issuance of a permit based on constn�ction docurr� � other d ta shali not prevent the building o�ciai from requiring gte correcti n of errors in the construction dxumeMa and other data. 'fh� D E N-4 4 8� V building o�icial is also authorized to prevent acxupancy or use of a structur where in violation of this c�de pr ��rty o� �d�a�s d ihisjuris iction, \ \\\��p\U11�illllllli p���i�/ / PLliNS XAMINER: pA� NFW FCJl11PMFNl" ANI� �,NTFNNAS . / ' _ — \ 330 � 0 30 � _ � �° 3 p ON AN EXISTING BUILDING = 30° �N 6°' Q - =270 � a 9p = � 240 1 Z0 � % \ # �oi�� zi o i so i so \��\�� �� //// / l I I� 1 I I I I I I I I I I\\\��\�\\\ MAGNETIC DECLINATION CODE BLOCK: BUILDING CODE: 2006 INTERNATIONAL BUILDWG CODE 2008 BAEC 2002 NATIONAL ELECTRIC CODE PROPOSED EQUIPMENT OCCUPANCY: 8 (UNMANNED TELEPHONE E�UIPMENT AND ANTENNA) WATER SUPPLY: NONE WASTE WATER: NONE PLUMBING: NONE 3 USE GROUP: U (uTiu7v) CONST. TYPE: V� SQ. FOOTAGE : 262 THE PROPOSED PROJECT INCLUDES: NEW 4'-0"xl3'-0" E�UIPMENT PLATFORM NEW ELEC7RICAL SERVICE NEW TELEPHONE SERVICE NEW ANTENNAS AND ALL ASSOCIATED PARTS THIS FACILITY SHALL MEET OR EXCEED ALL FAA AND FCC REGULATORY REQUIREMENTS PROJECT SUMMARY SHT. DESCRIPTION N0. � T-I TITLE SHEET 517E SURVEY A-I ROOF/SITE PLAN A-2 ELEVATIONS A-3 ELEVATIONS A-4 PLATFORM, ICE BRIDGE, & GPS DETAILS A-5 RF, ANTENNA, AND TRENCH DETAILS A-6 SITE DETAILS 5-I STRUCTURAL FRAMING PLAN, SECTIONS 4ND NOTES E-I GROUNDING PLAN 9 NOTES E-IJ ELECTRICAL DETAILS E-2 GROUNDING DETAILS E-3 PPC CABINET DETAILS E-4 ELECTRICAL DETAILS GN-I GENERAL NO7ES GN-2 GENERAL NOTES GN-3 GENERAL N07ES GN-L GENERAL NOTES SHEETINDEX Redi.,��"*wq, � �� ° i 0 �. .�� _ �.,� G�� �o�� ! �...� , .. °�, p�`'°y �,a LOCATION MAP a" r�, Sx+e;� c, y � �' a"`�;:,�� �'o - g � ,�. . FROM THE CRICKET OFFICE: SraRr our �oiNC WEST oN E 42ND AVE rownR� E 44TH AVE. 0.4 ni. E 42ND AVE eecones E 45TH AVE. 0.2 ni. TuRN LEFT ONTO PEORIA ST. 0.2 MI. MERGE ONTO I-70 W. 105.4 MI. TAKE EXIT 176 iawaRO VA!L. 0.2 ni. TuRN SLIGHT RIGHT. 0.0 Mi. TuRN SLIGHT LEFT. 0.0 ni. TuRN RIGHT oNio N FRONTAGE RD W. 0.1 MI. END AT 145 N FRONTAGE RD W VAIL, CO 81657-4573 SITE DIRE THE FOLLOWING PARTIES HEREBY APPROVE AND ACCEPT THESE DOCUMENTS AND AUTHORIZE THE CONTRACTOR TO PROCEED WITH THE CONSTRUCTION DESCRIBED HERIN. ALL DOCUMENTS ARE SUBJECT TO REVIEW BY THE LOCAL BUILDING DEPARTMENT AND MAY IMPOSE CHANGES OR MODIFICATIONS. CRICKET PROJECT MANAGER: — DATE: CRICKET R.F.: DATE: CRICKET NETOPS: DATE: CRICKET CONST.: DATE: CRICKET SA REP: DATE: CRICKET SITE DEV. MGR. DATE: PROPERTY OWNER.: DATE: APPROVALS 12875 East 42nd Avenue SUlie %� Denver, CO 80239 Office: 720.374.19ll Fax: 720.374.1890 D natek y I TELECOMMTJDiICATIONS SERVICES 7134 Brookwood Drive Brookfield, OH 44403 Phone:800-838-3224 Fax:330-448-4337 www. dynatektelecom. com DYNATEK 6758 PROJ. NO.: DRAWNBY: S.R.M. CHECKEDBY: D.C.B. SUBMITTALS 9/26/08 CODE REVIEW COMMENTS 2 9/10/OB CODE REVIEW COMMENTS I 7/IB/08 REDLWE REVISIONS I 0 5/19/06 ISSUED FOR REVIEW THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO CLIENT NAME IS STRI�.T.� � pp�tiIBITED. � O �� ev ��C \ ��/ iA� ` D,3111('� �. � �';�t��a� � ��.;. 0 sa as 63 � $,� � ��Ci� �I Z 96D� l VAIL 1VIIDI��,� CREEK DEN-448B 145 N. FRONTAGE ROAD WEST VAIL, CO 81657 SHEET i ITLE: TITLE SHEET SHEET NUMBER: T-1 GENERAL NOTES DRILLING & SAMPLING SYMBOLS: SS: Split Spoon - 1 3/8" I.D., 2" O.D., unless otherwise noted ST: Thin-Walled Tube - 2" O.D., unless otherwise noted RS: Ring Sampler - 2.42" I.D., 3" O.D., unless othervvise noted DB: Diamond Bit Coring - 4", N, B BS: Bulk Sample or Auger Sample HS: Hollow Stem Auger PA: Power Auger HA: Hand Auger RB: Rock Bit WB: Wash Boring or Mud Rotary The number of blows required to advance a standard 2-inch O.D. split-spoon sampler (SS) the last 12 inches of the total 18-inch penetration with a 140-pound hammer falling 30 inches is considered the "Standard Penetration" or "N-value". For 3" O.D. ring samplers (RS) the penetration value is reported as the number of blows required to advance the sampler 12 inches using a 140- pound hammer falling 30 inches, reported as "blows per foot," and is not considered equivalent to the "Standard Penetration" or "N- value". WATER LEVEL MEASUREMENT SYMBOLS: WL: Water Level WCI: Wet Cave in DCI: Dry Cave in AB: After Boring N/g: While Sampling WD: While Drilling BCR: Before Casing Removal ACR: After Casing Removal Water levels indicated on the boring logs are the levels measured in the borings at the times indicated. Groundwater levels at other times and other locations across the site could vary. In pervious soils, the indicated levels may reflect the location of groundwater. In low permeability soils, the accurate determination of groundwater levels may not be possible with only short-term observations. DESCRIPTIVE SOIL CLASSIFICATION: Soil classification is based on the Unified Classification System. Coarse Grained Soils have more than 50% of their dry weight retained on a#200 sieve; their principal descriptors are: boulders, cobbles, gravel or sand. Fine Grained Soils have less than 50% of their dry weight retained on a#200 sieve; they are principally described as clays if they are plastic, and silts if they are slightly plastic or non-plastic. Major constituents may be added as modifiers and minor constituents may be added according to the relative proportions based on grain size. In addition to gradation, coarse-grained soils are defined on the basis of their in-place relative density and fine-grained soils on the basis of their consistency. FINE-GRAINED SOILS � � Blows/Ft. Blows/Ft. Consistencv < 3 0-2 Very Soft 3-4 3-4 Soft 5_g 5-8 Medium Stiff 10-18 9-15 Stiff 1 g-42 16-30 Very Stiff > 42 > 30 Hard COARSE-GRAINED SOILS � � Relative BlowslFt. BlowslFt. Densi 0-6 < 3 Very Loose 7-18 4-9 Loose 19-58 10-29 Medium Dense 59-98 30-50 Dense > g8 > 50 Very Dense RELATIVE PROPORTIONS OF SAND AND GRAVEL Descriptive Terms of Percent of Other Constituents Drv WeiQht Trace With Modifier <15 15-29 > 30 RELATIVE PROPORTIONS OF FINES Descriptive Terms of Percent of Other Constituents Drv Weiqht Trace ` 5 With 5 —12 Modifiers ' 12 BEDROCK � � BlowslFt. Blows/Ft. Consistencv < 30 < 20 Weathered 30-49 20-29 Firm 50-89 30�9 Medium Hard 90-119 50-79 Hard > 119 > 79 Very Hard GRAIN SIZE TERMINOLOGY Maior Component of Samale Particle Size Boulders Over 12 in. (300mm) Cobbles 12 in. to 3 in. (300mm to 75 mm) Gravel 3 in. to #4 sieve (75mm to 4.75 mm) Sand #4 to #200 sieve (4.75mm to 0.075mm) Silt or Clay Passing #200 Sieve (0.075mm) PLASTICITY DESCRIPTION Term Plasticitv Index Non-plastic � Low 1-10 Medium 11-30 High 30+ �rr�cor� UNIFIED SOIL CLASSIFICATION SYSTEM Criteria for Assigning Group Symbols and Group Names Using Laboratory Tests" Clean Gravels Cu z 4 and 1 5 Cc s 3E Coarse Grained Soils Gravels More than 50% of coarse Less than 5% fines` Cu < 4 and/or 1> Cc > 3E More than 50% retained fraction retained on on No. 200 sieve No. 4 sieve Gravels with Fines More Fines classify as ML or MH than 12% fines° Fines classify as CL or CH Sands Clean Sands Cu z 6 and 1<_ Cc 5 3E 50% or more of coarse Less than 5% fines° Cu < 6 and/or 1> Cc > 3E fraction passes Fines classi as ML or MH No. 4 sieve Sands with Fines �' More than 12% fines° Fines classify as CL or CH PI > 7 and lots on or above "A° line' Fine-Grained Soils Silts and Clays inorganic P 50% or more passes the Liquid limit less than 50 p� < 4 or plots below "A" line' No. zoo sieve Liquid limit - oven Highly organic soils organic c 0.75 dried Liquid limit - not dried Silts and Clays inorganic PI plots on or above "A" line Liquid limit 50 or more pl plots below "A" line organic Liquid limit - oven dried � p 75 Liquid limit - not dried Primarily organic matter, dark in color, and organic odor "Based on the material passing the 3-in. (75-mm) sieve B If field sample contained cobbles or boulders, or both, add 'lvith cobbles or boulders, or both" to group name. �Gravels with 5 to 12% fines require dual symbols: GW-GM well graded gravel with silt, GW-GC well graded gravel with clay, GP-GM poorly graded gravel with silt, GP-GC poorly graded gravel with clay. °Sands with 5 to 12% fines require dual symbols: SW-SM well graded sand with silt, SW-SC well graded sand with clay, SP-SM poorly graded sand with silt, SP-SC poorly graded sand with clay (D3°) ECu = D6�/D�o Cc =�o x Deo F If soil contains >_ 15% sand, add "with sand" to group name. �If fines classify as CL-ML, use dual symbol GC-GM, or SC-SM. n. X W 0 Z r � U � 5 a Group GW GP GM GC SW SP SM SC CL ML OL CH MH OH PT Soil Classification Group NameB Well graded gravelF Poorly graded gravelF Silty gravel`,�," Clayey gravelF���" Well graded sand' poorly graded sand' Silty sand��"•' Clayey sand��"•' Lean clay's`•" SIILK.L.M Organic ciay"`•"'" Organic siltK`•1AO Fat ciay"`�"' Elastic silt"`�"" Organic clay'4� M�P Organic silt'�`"".o Peat "If fines are organic, add 'tivith organic fines" to group name. ' If soil contains ? 15% gravel, add 'tivith gravel" to group name. ' If Atterberg limits plot in shaded area, soil is a CL-ML, silty clay. "If soil contains 15 to 29% plus No. 200, add 'Y�ith sand" or "with gravel," whichever is predominant. � If soil contains ? 30% plus No. 200 predominantly sand, add "sandy" to group name. "'If soil contains >_ 30% plus No. 200, predominantly gravel, add "gravelly" to group name. "PI >_ 4 and plots on or above "A" line. °PI <4 or plots below "A" line. P PI plots on or above "A" line. °PI plots below "A" line. 6o r------- , '� For classification of fine-grained ' sofis and fine-grained fraction � ; - of coarse-grained soils --- J�,Se ! Equation of "A" - line � Horizontal at Pi=4 to LL=25.5. ,'� , RO ; lhen PI=0.73 (LL-20) - - __. , .`� � -10 ' Equation ot "U" - iina G�- � Vertical at �L=18 to P1=7, ,'� � 3p i then PI_D.9 {LL-Bl ;'� . � to !---- 4 r--- oi - --.- 0 ,.'��,��G�! ��� .� .. .�.��..�. . � MH or OH � ML or OL �`�� . ...._.._.._..... .__. ....._ �o is Zo so ao so so �o eo so ioo »a LIQUiD LIMIT (LL) 1 f�rr�cO� � TEST California Bearing Ratio Consolidation Direct Shear Dry Density Expansion Gradation LABORATORY TEST SIGNIFICANCE AND PURPOSE SIGNIFICANCE PURPOSE Used to evaluate the potential strength of subgrade soil, Pavement Thickness subbase, and base course material, including recycled Design materials for use in road and ai�eld pavements. Used to develop an estimate of both the rate and amount of Foundation Design both differential and total settlement of a structure. 'Used to determine the consolidated drained shear strength Bearing Capacity, of soil or rock. Foundation Design, and Slope Stability Used to determine the in-place density of natural, inorganic, Index Property Soil fine-grained soils. Behavior Used to measure the expansive potential of fine-grain� soil and to provide a basis for swell potential classification Used for the quantitative determination of the distribution particle sizes in soil. Liquid 8 P/astic Limit, Used as an integral part of engineering classification Plasticity Index systems to characterize the fine-grained fraction of soils, and to specify the fine-grained fraction of construction materials. Permeability Used to determine the capacity of soil or rock to conduct a liquid or gas. pH Resistivity R-Value Soluble Sulphate Unconfined Compression Water Content Foundation and Slab Design Soil Classification Soil Classification Groundwater Flow Ana/ysis Used to determine the degree of acidity or alkalinity of a Corrosion Potential soil. Used to indicate the relative ability of a soil medium to carry Corrosion Potential electrical currents. Used to evaluate the potential strength of subgrade soil, Pavement Thickness subbase, and base course material, including recycled Design materials for use in road and airfield pavements. Used to determine the quantitative amount of soluble Corrosion Potential sulfates within a soil mass. To obtain the approximate compressive strength of soils Bearing Capacity that possess sufficient cohesion to permit testing in the Founda'tions unconfined state. Used to determine the quantitative amount of water in a soil Inde Behavior Soil mass. �r� Allowable Soil Bearing Capacity Alluvium Aggregate Base Course Backfill REPORT TERMINOLOGY (Based on ASTM D653) The recommended maximum contact stress developed at the interface of the foundation element and the supporting material. Soil, the constituents of which have been transported in suspension by flowing water and subsequently deposited by sedimentation. A layer of specified material placed on a subgrade or subbase usually beneath slabs or pavements. A specified material placed and compacted in a confined area. Bedrock A natural aggregate of mineral grains connected by strong and permanent cohesive forces. Usually requires drilling, wedging, blasting or other methods of extraordinary force for excavation. Bench A horizontal surface in a sloped deposit. Caisson (Drilled A concrete foundation element cast in a circular excavation which may have an enlarged Pier or Shaft) base. Sometimes referred to as a cast-in-place pier or drilled shaft. Coefficient of A constant proportionality factor relating normal stress and the corresponding shear stress Friction at which sliding starts between the two surfaces. Colluvium Soil, the constituents of which have been deposited chiefly by gravity such as at the foot of a slope or cliff. Compaction Concrete Slab-on- Grade Differential Movement Earth Pressure ESAL Engineered Fill Equivalent Fluid Existing Fill (or Man-Made Fill) Existing Grade The densification of a soil by means of inechanical manipulation A concrete surface layer cast directly upon a base, subbase or subgrade, and typically used as a floor system. Unequal settlement or heave between, or within foundation elements of structure. The pressure exerted by soil on any boundary such as a foundation wall. Equivalent Single Axle Load, a criteria used to convert traffic to a uniform standard, (18,000 pound ax�e loads). Specified material placed and compacted to specified density and/or moisture conditions under observations of a representative of a geotechnical engineer. A hypothetical fluid having a unit weight such that it will produce a pressure against a lateral support presumed to be equivalent to that produced by the actual soil. This simplified approach is valid only when deformation conditions are such that the pressure increases linearly with depth and the wall friction is neglected. Materials deposited throughout the action of man prior to exploration of the site. The ground surface at the time of field exploration. l��r Expansive Potential Finished Grade Footing Foundation Frost Depth Grade Beam Groundwafer Heave Lithologic Native Grade Native Soil REPORT TERMINOLOGY (Based on ASTM D653) The potential of a soil to expand (increase in volume) due to absorption of moisture. The final grade created as a part of the project. A portion of the foundation of a structure that transmits loads directly to the soil. The lower part of a structure that transmits the loads to the soil or bedrock. The depth at which the ground becomes frozen during the winter season. A foundation element or wall, typically constructed of reinforced concrete, used to span befinreen other foundation elements such as drilled piers. Subsurface water found in the zone of saturation of soils or within fractures in bedrock. Upward movement. The characteristics which describe the composition and texture of soil and rock by observation. The naturally occurring ground surface. Naturally occurring on-site soil, sometimes referred to as natural soil. Optimum Moisture The water content at which a soil can be compacted to a maximum dry unit weight by a Content given compactive effort. Perched Water Groundwater, usually of limited area maintained above a normal water elevation by the presence of an intervening relatively impervious continuous stratum. Scarify Settlement To mechanically loosen soil or break down existing soil structure. Downward movement. Skin Friction (Side The frictional resistance developed between soil and an element of the structure such as a Shear) drilled pier. Soil (Earth) Sediments or other unconsolidated accumulations of solid particles produced by the physical and chemical disintegration of rocks, and which may or may not contain organic matter. Strain Stress Strip Subbase Subgrade The change in length per unit of length in a given direction. The force per unit area acting within a soil mass. To remove from present location. A tayer of specified material in a pavement system between the subgrade and base course. The soil prepared and compacted to support a structure, slab or pavement system. 1 ��r B08-0261: Entries for Item:90 - BLDG-Final 14:39 10/12/2012 Action Comments By Date Unique_ Ke DN 1) APPROVED PLANS NOT ON SITE CG 06/10/2010 A000133 2) PROVIDE ACCESS TO INSIDE OF 738 BUILDING 3) POSITIVE DRAINAGE REQUIRED AROUND BUILDING 4) PLANNING FINAL INSPECTION REQUIRED 5) PROVIDE EXTERIOR LANDING AT MAN DOOR 6) PLYWOOD EXPOSED TO WEATHER AND BURIED IN DIRT 7) INSTALL DRIP EDGE AT ROOF FACIA 8) SOUTH AND EAST WALLS WERE FIRE RATED AND WERE REQUIRED TO BE BUILT TO SOLID FOUNDATION 9) NEED TO CHECK APPROVED PLANS FOR BOTTOM OF EXTERIOR WALL TERMINATION DETAIL. SONOTUBES LEFT EXPOSED, LATTICE INSTALLED OVER GAPS AP cg 06/14/2010 A000148 820 Total Rows: 2 Page 1 E08-0257: Entries for Item:190 - ELEC-Final 14:40 10/12/2012 Total Rows: 1 Page 1 A09-0067: Entries for Item:538 - FIRE-FINAL C/O 14:39 10/12/2012 Comments � By � Date � Unique_ AP Total Rows: 1 mvaughan 06/04/2010 A000133 591 Page 1