Loading...
HomeMy WebLinkAboutA12-0067 application/'''.,.r'--- FIRE ALARM PERMIT Commercial and Residential Fire Alarm shop drawings are required at the time of application submittal and must included information listed on the 2nd page of this form,Application will not be accepted without this information, Project #_ contractor/hnfor at19n:t'1/-/"----Company I uL..-=ec..!.7ra~c ~foJ Company Address 'J "i/en~7c~(;:::if -tL City:,,4//C2t-J State &()Zip y~o Contact Name ,00"1 4[-7c~r/C/j Contact Phone <1 '70 7Zti J 7'.,z.z .i7.'1 9//.r:»/_r r:.(use additional sheet if necessary)E-Mail f::/vVZ~l.~./~l./S?{.h •.•~..C.[..I.n #ft7..:?I c/Does a Fire Alarm Exist?tor Registration No.:-"2~'--L~,--,G---~_ Does a Sprinkler System Exist?Yes ()No ()r Lot#:Block #Subdivision:_ Project Street Address:~0 j,p m~at·tr-I'•. (Number)(Street)(Suite #)~'~F r s '--JBuilding/ComFllexName:~(I ~2fl ~}~rrN.r;//;to;;:,y'{C.J2n Tr£r Office Use: Building Permit #_ Alarm Permit #:_ Detailed Description ofwork.4fC/'rZ Chf~-16 OIL(-ft;rn 849 =t 24P1c.tUz rr:, Yes P4-No () x s-e-~Work Class: New ()Addition ()Remodel ~Repair ( Retro-Fit ()Other (Property Information Parcel #2/0/-07/-0/-OJ.-'g (For parcel #,contact Eagle County Assessors Office at 970-328-8640 or visit www.eaglecounty.us/patie) Type of Building: Single-Family ()Duplex ()Multi-Family ( Commercial ~Restaurant ()Other ()TenantName:_ ownerName~t7 ~)?.q;p,kr;~J Date Received: Complete Valuation for Fire Alarm Permit (Tv6..,-'Fire Alarm $~~O 29-May·09 By David Rhoades at 2:31 pm, Oct 12, 2012 PRJ12-0485 B12-0445 A12-0067 V~I LELEC:TR~NIC:SINC EN T E R T A IN MEN T·SEe U R I TY·FIR E _CUSTOM ELECTRONIC DESIGN & ••INSTAlLATION •ASSOCIATION Member Go Ahead.Live Comfortably. We support and encourage NICfT certification October 6,2012 Vail Fire and Emergency Services Attn:Mike V 2399 N Frontage Rd W Vail CO 81657 RE:Village Center Commercial,Old Bag and Pack Space,122 E Meadow Dr.Vail Mike, We are seeking a permit to add 2 -System Sensor horn strobes at Village Center Commercial,122 E Meadow Dr,Vail CO.The current amp on the circuit is 1.23 with a total of 3 amps available.The System Sensor ceiling mount horn strobe uses 196 MA on temporal medium.The estimated amp draw after the 2 horn strobes are installed is 1.62 amps,well within the panel limits. Battery calculations show 3.4amp in alarm,54 Ma quiescent.Adding the 2 horn strobes will increase the alarm amp draw to 3.79amp in alarm and no change in quiescent state.Battery calculations are estimated to be 14.45 Ah needs.The current battery capacity is 17Ah. Don Anderson NICST 119424 Phone:970.827.9120 Fax:970.827.9126 910 Nottingham Road,Unit N-1,Avon,CO 81620 Mailing:P.O.Box 3940,Avon,CO 81620 ~SYSTEM'---~SENSOR® Indoor Selectable- Output Strobes and Horn Strobes for Ceiling Applications SpectrAlerf®Advance audible visible notification products are rich with features guaranteed to cut installation times and maximize profits. Features •Plug-in design with minimal intrusion into the back box •Tamper-resistant construction •Automatic selection of 12-or 24-volt operation at 15 and 15/75 candela •Field-selectable candela settings on ceiling units:15,15/75,30, 75,95,110,115,135,150,177,and 185 •Horn rated at 88+dBA at 16 volts •Rotary switch for horn tone and three volume selections •Universal mounting plate for ceiling units •Mounting plate shorting spring checks wiring continuity before device installation •Electrically Compatible with legacy SpectrAlert devices •Compatible with MOL sync module •Listed for ceiling or wall mounting Agency Listings S16NAUNG® LISTED <8> APPROVED 54011 (chimes,hom strobes,horns)3023572 S5512 (strobes) MEA approved MEA452-OS~E 7125-1653;186 (indoor strobes) 7125-1653:188 (horn strobes, chime strobes) 7135-1653:189 (horns,chimes) SPECTR'AlertA.•g.,x.Ae.&J.i •.1e The SpectrAlert Advance series offers the most versatile and easy-to-use line of horns,strobes,and horn strobes in the industry. With white and red plastic housings,wall and ceiling mounting options,and plain and FIRE-printed devices,SpectrAlert Advance can meet virtually any application requirement. Like the entire SpectrAlert Advance product line,ceiling-mount strobes and horn strobes include a variety of features that increase their application versatility while simplifying installation.All devices feature plug-in designs with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time-consuming ground faults. To further simplify installation and protect devices from construction damage,SpectrAlert Advance utilizes a universal mounting plate with an onboard shorting spring,so installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, automatic selection of 12-or 24-volt operation,and a rotary switch for horn tones with three volume selections. SpectrAlert Advance Specifications Architect/Engineer Specifications General SpectrAlert Advance strobes and horn strobes shall mount to a standard 4 x 4 x 1Y2-inch back box,4-inch octagon back box,or double- gang back box.Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box.A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate.Also,SpectrAlert Advance products,when used with the Svnc-Circult"Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync-Circuit Module,12-volt-rated notification appliance circuit outputs shall operate between 9 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 17 and 33 volts. Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply.Strobes and horn strobes shall have field-selectable candela settings including 15,15(15,30,75,95,110,115,135, 150,177,and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance MOdel listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens!reflector system.The horn shall have three audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous)pattern.These options are set by a multiple position switch.On four-wire products,the strobe shall be powered independently of the sounder.The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync-Circuit model MOL listed to UL 464 and shall be approved for fire protective service.The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three.Also,while operating the strobes,the module shall silence the horns on horn strobe models over a single pair of wires.The module shall mount to a 411116 x 411/16 x 21/8-inch back box.The module shall also control two Style Y (class 8)circuits or one Style Z (class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F (DOCto 49°C) Humidity Range 10 to 93%non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR' Operating Voltage Range2 8 to 17.5 V (12 V nominal)or 16 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Ceiling-Mount Dimensions (including lens)6.W'diameter x 2.5"high (173 mm diameter x 64 mm high) Ceiling-Mount Back Box Skirt Dimensions (BBSC-2,BBSCW-2)7.1 "diameter x 2.2"high (180 mm diameter x 57 mm high) Ceiling-MountTrim Ring Dimensions (sold as a 5 pack)(TRC-HS, TRCW-HS) 6.9"diameter x D.35"high (175 mm diameter x 9 mm high) Notes: 1.Full Wave Rectified (FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.P,S,PC,and SC products will operate at 12 V nominal only for 15 and 15(15 cd. AVDS00501 UL Current Draw Data ULMax.Strobe Current Draw (mA RMS) 8-17.5 Volts 16-33 Volts Candela DC FWR DC FWR Standard Candela Range 15 123 128 66 71 15{75 142 148 77 81 30 NA NA 94 96 75 NA NA 158 153 95 NA NA 181 176 110 NA NA 202 195 115 NA NA 210 205 High 135 NA NA 228 207 Candela Range 150 NA NA 246 220 177 NA NA 281 251 185 NA NA 286 258 ut,Max.Current Draw (mA RMS),2-Wire Horn Strobe,Standard Candela Range (15-115 cd) 8-17.5 Volts 16-33 Volts DC Input 15 15n5 15 15n5 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non-Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-Temporal High 142 161 103 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low 132 154 80 90 105 161 184 202 211 UL Max.Current Draw (mA RMS),2-Wire Horn Strobe,High Candela Range (135-185 cd) 16-33 Volts 16-33 Volts DC Input 135 150 1n 185 FWR Input 135 150 1n 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 295 Non-Temporal Low 214 229 256 262 Horn Strobe Tones and Sound Output Data Horn Strobe Output (dBA) 8-17.5 16-33 24-Volt Nominal Switch Volts Volts Reverberant Anechoic Position Sound Pattern dB DC FWR DC FWR DC FWR DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 74 74 80 80 86 86 96 96 3 Temporal Low 71 73 76 76 83 80 94 89 4 Non-Temporal High 82 82 88 88 93 92 100 100 5 Non-Temporal Medium 78 78 85 85 90 90 98 98 6 Non-Temporal .Low 75 75 81 81 88 84 96 92 7t Coded High 82 82 88 88 93 92 101 101 8t Coded Medium 78 78 85 85 90 90 97 98 9t Coded Low 75 75 81 81 88 85 96 92 tSettings7,8,and 9 are not availableon 2-wire horn strobes. AVDSOO501 SpectrAlert Advance Dimensions ,--C ;1I\Iy'"§;:I J d 7 S:7 P8: '0 0 (J Ceiling-mount horn strobes Ceiling back box skirt SpectrAlert Advance Ordering Information Ceiling Horn Strobes Ceiling Strobes Model DescriptionModelDescription PC2R*2-Wire Horn Strobe,Standard cd,Red SCR Strobe,Standard cd,Red PC2RH 2-Wire Horn Strobe,High cd,Red SCRH Strobe,High cd,Red PC2W*t 2-Wire Horn Strobe,Standard cd,White SCW*Strobe,Standard cd,White PC2WH*2-Wire Horn Strobe,High cd,White SCWH Strobe,High cd,White PC4R 4-Wire Horn Strobe,Standard cd,Red Accessories PC4W 4-Wire Horn Strobe,Standard cd,White Back Box Skirt,Ceiling,White PC4RH 4-Wire Horn Strobe,High cd,Red BBSC-2 Back Box Skirt,Ceiling,Red TRC-HS Trim Ring,Ceiling,Red TRCW- HS Trim Ring,Ceiling,White Notes: *Add "-P"to model number for plain housing (no "FIRE"marking on cover),e.g.,P2R-P. t Add "-SP"to model number for "FUEGO"marking on cover,e.g.,P2R-SP. :j:"Standard cd"refers to strobes that include 15,15/75,3D,75,95,110,and 115 candela settings."High cd"refers to strobes that include 135,150,177,and 185 candela settings. ~SYSTEM '-~SENSOR~3825 Ohio Avenue·St.Charles,IL 60174 Phone:800-SENSOR2 •Fax:630-377-6495 @2012SystemSensor. Product specifications subject to change without notice.Visit systemsensor.corn for current product informatirn,including the latest version of this data sheet. AVDSOCSOl ·3/12