HomeMy WebLinkAboutB12-0558NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES
,.
�row�a�v� .
Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657
p. 970.479.2139, f. 970.479.2452, inpsections 970.479.2149
COMBINATION BLDG PERMIT Permit #: B12-0558
Job Address: 263 E GORE CREEK DR VAIL
Location......: GORSUCH LTD TOWER
Parcel No....: 210108229003
OWNER GORSUCH LTD - MCBRIDE, JOHN 10/16/2012
263 E GORE CREEK DR
VAIL, CO
81657
APPLICANT PLATH CONSTRUCTION, INC 10/16/2012
PO BOX 3367
EAGLE
CO 81631
License: C000003109
Project #: PRJ12-0532
Applied.....: 10/16/2012
Issued. . . : 10/2412012
Phone: 970-328-5515
CONTRACTOR PLATH CONSTRUCTION, INC 10/16/2012 Phone: 970-328-5515
PO BOX 3367
EAGLE
CO 81631
License: C000003109
Description:
RE ROOF TOWER OF GORSUCH LTD WITH DAVINCI SLATE BLACK COLOR
Occupancy:
Type Construction:
Valuation: $13,727.00
............�,..,,......,,..� ............................,........................... FEE SUMMARY .........+...,.,.,......,...»......�.........,�..�.,.,..,...........................,�
Building Permit -----------> $237.25 Bldg Plan Check ----------> $154.21 Use Tax Fee-----------------------> $74.54
Electrical Permit ---------> $0.00 Elec Plan Check -----------> $0.00 Restuarant Plan Review--------> $0.00
Mechanical Permit ------> $0.00 Mech Plan Check ---------> $0.00 Additional Fees--------------------> $0.00
Plumbing Permit --------> $0.00 Plmb Plan Check ---------> $0.00 Recreation Fee--------------------> $0.00
Investigation-----------------------> $0.00
Will Call------------------------------> $5.00
TOTAL PERMIT FEES--------------> $471.00
Payments-------------------------------> $471.00
BALANCE DUE------------------------> $0.00
......................................................................................................x...==...z...=............«......._,.......,...................................,
DECLARATIONS
I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure
according to the town's zoning and subdivision codes, design review approved, International Building and Residential Codes and
other ordinances of the Town applicable thereto.
REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149
OR AT OUR OFFICE FROM 8:00 AM - 4:00 PM.
combination permit_012811
�
�
�
��� V� �� j
.+e..�..•.x.v.x•...++.x..ex.+x+�.x....e�•..e+...••�+..�e•.•+.+xx.:a.x..�xwx..•.rx.+...x�....x..+.»....•«.wwx..x..x.rx...:wwx•.:.xe...+w•...»e•+.•..+r..x..w.x.e..•x..ww:..�x+....xw...+
CONDITIONS OF APPROVAL TO BE MET PRIOR TO FINAL SIGN OFF
Permit #: B12-0558
Owner: GORSUCH LTD - MCBRIDE, JOHN P.
Address: 263 E GORE CREEK DR VAIL
Location:
GORSUCH LTD TOWER
...........,..,,,� ......................................................................................�.,....�,.....,.................,..�..,.......�,,.,..,..,....,......�.,........
combination permit_012811
�i
i
i
T'�iNN QF VAI� '
,**************************************�***,****,****,.******************�********************,*,*.,****,.**********„*,************.******************
REQUIRED INSPECTIONS AND STATUSES
Permit #: 612-0558
Owner: GORSUCH LTD - MCBRIDE, JOHN P.
GORSUCH LTD TOWER
Address: 263 E GORE CREEK DR VAIL
Location:
«***�*.,******«************«*****«*«***««*.,**««««.,********.,«***�*************«****.,************.,*******«****«*«*«*************«*****«***«*„**«*„*�«„*„
Item: 00542 PLAN-FINAL
Item: 00090 BLDG-Final
combination permit_012811
**************************************************�************************************10/24/2012
TOWN OF VAIL, COLORADOCopy Reprinted on 10-24-2012 at 10:13:28
Statement
*******************************************ount** 5316 *79*10/24/201210* 13*�********
Statement Number: R120001�40 Am Init. CG
Payment Method: Check Notation: #3'7629 Plath
Construction ---------------------'----
---
----------------------------
Permit No: B12-0558
Type: COMBINATION BLDG PERMI
Parcel No: 2101-082-2900-3
Site Address: 263 E GORE CREEK DR VAIL $q�1.00
Location: GORSUCH LTD TOWER Total Fees: $4�1.00
$316.`19 Total ALL Pmts: $p,00
This Payment: Balance:
**********************�*********************************************************************
ACCOLJNT ITEM LIST: Current_Pmts
Description ___
Account Code -------------
-------------- ---- 237.25
BUILDING PERMIT FEES �4.54
BP 00100003111100 USE TAX 4% 5.00
UT 11000003106000 WILL CALL INSPECTION FEE
WC 00100003112800 _______
a- DS 3
1 �.
��
12-05-2012 Inspection Request Reporting Page 13
4: 9 om Vail, Cn �itv Of
Requested inspect Date: Thursday, December 06, 2012
Site Address: 263 E GORE CREEK DR VAIL
GORSUCH LTD TOWER
A/P/D Information
Activity: 612-0558 Type: COMBO Sub Type: ACOM Status: ISSUED
Const Type: Occu ancy : Use: Insp Area:
Owner: GORSUCH LTD - MCBRID�, JOHN P.
Contractor: PLATH CONSTRUCTION, INC Phone: 970-328-5515
Description: RE ROOF TOWER OF GORSUCH LTD WITH DAVINCI SLATE BLACK COLOR
Requested Inspection(s)
Item: 542 PLAN-FINAL Requested Time: 08:15 AM
Requestor: PLATH CONSTRUCTION, INC Phone: 970-328-5515
Comments: 328-5515
Assigned To: BGIBSON tered By: JMONDRAGON K
Action: Time E :
Gv��. I � � ' (�--
Item: 90 BLD -Final Requested Time: 01:00 PM
Requestor: PLATH CONSTRUCTION, INC Phone: 970-328-5515
Comments: 328-5515
Assigned To: JMONDRAGON Entered By: JMONDRAGON K
Action: Time Exp:
Inspection Historv
Item: 542 PLAN-FINAL
Item: 90 BLDG-Final
REPT131 Run Id: 14651
,�., a.
� •
12-05-2012 Inspection Request Reporting(� Page 13
4:29 pm Vail_ C� - Citv �f W���2 -h�Z
Requested Inspect Date: Thursday December 06, 2012
Site Address: 263 E GO�tE CREEK DR VAIL
GORSUCH LTD TOWER
A/P/D Information
Activity: 612-0558 Type: COMBO Sub Type: ACOM
Const Type: Occu ancy : Use:
Owner: GORSUCH LTD - MCBRID�, JOHN P.
Contractor: PLATH CONSTRUCTION, INC Phone: 970-328-5515
Description: RE ROOF TOWER OF GORSUCH LTD WITH DAVINCI SLATE BLACK COLOR
Reauested Insaection(s)
Item: 542 PLAN-FINAL
Requestor: PLATH CONSTRUCTION, INC
Comments: 328-5515
Assigned To: BGIBSON
Action: Time Exp:
Item: 90 BLDG-Final
Requestor: PLATH CONSTRUCTION, INC
Comments: 328-5515
Assigned To: JMONDRAGON
Action: Time Exp:
Inspection Historv
Item: 542 PLAN-FINAL
Item: 90 BLDG-Final
Status: ISSUED
Insp Area:
Requested Time: 08:15 AM
Phone: 970-328-5515
Entered By: JMONDRAGON K
Requested Time: 01:00 PM
Phone: 970-328-5515
Entered By: JMONDRAGON K
REPT131 Run Id: 14651
TOWN OF VAII
Department of Community Development
75 South Frontage Road
Vail, CO 81657
Tel: 970 -479 -2128
www.vailgov.com
Development Review Coordinator
BUILDING PERMIT APPLICATION
(Separate applications are required for alarm & sprinkler)
Project Street Address:
26, 606C 0,X--Ek DR r v �
(Number) (Street) (Suite #)
Building /Complex Name: 9R,SVcL 41dg
Contractor Information
Business Name: %j�'7` �011LS 14 C16—Ta I1/ L/l c—
Business Address: 7Q i ok 3367
Project #:
DRB #: .1)r
Building Permit #: ��a — g
Lot #:C-1C- Block # S Subdivision:l/R�L
Work Class: New 0 Addition 0 Alteration (0
City State: Zip: Type of Building:
�L96R7c_ OeiC�6.�' Single- Family
Contact Name: _ (G) /� Commercial (�
Contact Phone: ��� — SS /�
Contact E-Mail: 14 L& 6 i o C A2 & ROd Work Type:
I hereby acknowledge that I have read this application, filled out
in full the information required, completed an accurate plot plan,
and state that all the information as required is correct. I agree to
comply with the information and plot plan, to comply with all Town
ordinances and state laws, and to build this structure according to
the town's zoning and subdivision codes, design review ap-
proved, International Building and Residential Codes and other
ordinances of the Town applicable thereto.
Ov er /Owner's Represen ative Signature (Required)
Applicant Informatio�n"
Applicant Name: PION LENS //� UG 1 �'d i✓ �/I/�
Applicant Phone: 3 2oo - i /l5
Duplex 0 Multi - Family (l.
Other 0
Interior 0 Exterior Both
Valuation of
Work Included Plans Included Work
Electrical 0Yes
ONO
OYes
ONO
Mechanical ()Yes
U)No
OYes
0No
Plumbing ()Yes
ONO
0Yes
GNo
Building OYes
ONO
OYes
ONO
Value of all work being performed: $ 1 y �_ - 0 m
(value based on IBC Section 109.3 & IRC Section 108.3)
Electrical Square Footage
Detailed Scope and Location of Work:
- & ", lyp 75w6_9 OF Cam- x ola LTai U, i
Applicant E -Mail: 4a6Ar0&,J_6 ? Xed f (i✓6, edy,7
Project Information nn /
Owner Name: C5Z:, "4S1/C� L- -rc_
Parcel #: 21010 9ZZ9CO 3
(For Parcel #, contact Eagle County Assessors Office at (970- 328 -8640 or visit
www.eaglecounty.us/patie)
For Office Use Only:
Fee Paid:
Received From:
Cash Check #
CC: Visa / MC Last 4 CC # exp date:
Auth #
(use additional she
Date Received:
et it necessa
-1IVA :10 NMOl
Z10l " `[
nn nn a
RN
CU-M nrrDE4ULOPXIENT
Design Review Board
ACTION FORM
Department of Community Development
75 South Frontage Road, Vail, Colorado 81657
tel: 970.479.2139 fax: 970.479.2452
web: www.vailgov.com
Project Name: GORSUCH TOWER REROOF DRB Number: DRB120423
Project Description:
RE -ROOF THE TOWER OF THE GORSUCH BUILDING IN VAIL VILLAGE WITH DAVINCI SLATE
CASTLE GREY COLOR
Participants:
OWNER GORSUCH LTD - MCBRIDE, JOHN 09/10/2012
263 E GORE CREEK DR
VAIL, CO
81657
APPLICANT PLATH CONSTRUCTION, INC 09/10/2012 Phone: 970 - 328 -5515
PO BOX 3367
EAGLE
CO 81631
License: C000003109
Project Address: 263 GORE CREEK DR VAIL
GORSUCH LTD TOWER
Location:
Legal Description: Lot: E Block: 5 Subdivision: VAIL VILLAGE FILING 1
Parcel Number: 2101 - 082 - 2900 -3
Comments: See conditions
BOARD /STAFF ACTION
Motion By: Kjesbo Action: APPROVED
Second By: Gillette
Vote: 5 -0 -0 Date of Approval: 10/03/2012
Conditions:
Cond: 8
(PLAN): No changes to these plans may be made without the written consent of Town of
Vail staff and /or the appropriate review committee(s).
Cond: 0
(PLAN): DRB approval does not constitute a permit for building. Please consult with
Town of Vail Building personnel prior to construction activities.
Cond: 201
(PLAN): DRB approval shall not become valid for 20 days following the date of
approval, pursuant to the Vail Town Code, Chapter 12 -3 -3: APPEALS.
Cond:202
(PLAN): Approval of this project shall lapse and become void one (1) year following
the date of final approval, unless a building permit is issued and construction is
commenced and is diligently pursued toward completion.
DaVind Slate
Technical Information.
Field Shingle Dimensions
Widths
1211, 10 ", 9 ", 7 ", 6"
Thickness at Butt
1/2"
Length
18"
Thickness at Top
1/8"
Hip - Ridge - Starter
* At recommended 6" exposure.
** Starter Course shingle is 3/8" at butt.
Note: 9" slates available for ridge; 4" slates available for turrets.
Field Shingles per Roofing Square
Roof Pitch
6" Hip & Ridge
(for ridge vents only)
7" Hip & Ridge
(Standard)
12" Starter **
Pieces / Bundle
20
20
30
Lineal Ft / Bundle
5*
5*
30
Pieces / Lineal Ft
4*
4*
1
* At recommended 6" exposure.
** Starter Course shingle is 3/8" at butt.
Note: 9" slates available for ridge; 4" slates available for turrets.
Field Shingles per Roofing Square
Roof Pitch
Coursing
Max. Exposure
Bundles /Square
Shingles /Square
Weight /Square
6" in 12" or greater
Straight
7.5"
7.00
210
273 lbs
6" in 12" or greater
Staggered
7.0"
7.50
225
283 lbs
Less than 6" in 12"
Straight or Staggered
6.0"
8.75
262
342 lbs
Note l: All calculations are based on using the recommended 3/8" gap between shingles.
Note 2: Straight coursing may be used at any exposure up to 7.5 "; staggered coursing may be used at any exposure up to 7.0"
Packaging and Shipping Information
* All weights are approximate.
** 48 Bundles per Pallet
* ** 24 Pallets per Truckload
,
11320 W. 79th St. Lenexa, KS 66214 Toll -free: 800 - DaVinci (328 -4624) Phone: 913 - 599.0766 Fax: 913 - 599.0065
www.davinciroofscapes.com
Testing Summary
Type of Test
# Shingles
Weight
Per Bundle
30
39 lbs
Per Pallet **
1,440
1,872 lbs
Per Truckload * **
34,560
44,9281bs
* All weights are approximate.
** 48 Bundles per Pallet
* ** 24 Pallets per Truckload
,
11320 W. 79th St. Lenexa, KS 66214 Toll -free: 800 - DaVinci (328 -4624) Phone: 913 - 599.0766 Fax: 913 - 599.0065
www.davinciroofscapes.com
Testing Summary
Type of Test
Standard
Results
Fire Test
UL 790
Class A
Impact Test
UL 2218
Class 4
Wind Test
ASTM D 3161
Certified to 110 MPH
12/05 Printed 12127/05
PRODUCT FEATURES
EXPOSURE
With DaVinci Slate, the allowable exposure depends on two
factors:
1. Roof Pitch
2. Whether the slates are laid staggered or straight.
Use Exposure Alignment Guides with the top edge of the
previous row of slates to control the exposure.
ROOF PITCH
COURSING
E7iPOSURE
less than 2:12
Not Recommended
* 2:12 to 4:12
Straight or Staggered
6"
4:12 to 6:12
Straight or Staggered
6"
6:12 or greater
Staggered
7"
amp Patlffilllffip��
Nails
Non - corrosive
* For slopes between 2:12 and 4:12, an ice water shield is required over the
entire area.
NAILING
Each shingle should be applied with two corrosion - resistant,
3/8" head x 1'h" length nails. Slates can be nailed by hand or
with a pneumatic nail gun. Don't overdrive nails or nail at an
angle. Keep the nail head flush with the surface of the shingle
to avoid creating "craters" which can collect moisture and can
also prevent the exposed end of the shingles from laying flat.
Use these alignment guides with the top edge of the previous
row of slates to control the exposure.
CUTTING
DaVinci Slate can be cut with a utility knife and straight edge.
Electrical circular saws (carbide blade, two teeth per inch) or
cordless circular saws (a minimum of 18 volts is recommended)
may also be used.
NATURAL APPEARANCE QUICK REFERENCE
To produce the most natural and realistic appearance,
DaVinci Slate is modeled directly from actual slate
shingles. Scientifically engineered, reinforcing ribs on
the back of the shingle add stability and strength.
Please note: DaVinci Slate is made flat, should be stored
flat, and must not be installed unless it is flat and in its
original form. If slates are not stored flat and become
twisted or curled, lay them flat in a warm place and they
will return to their original flatness. Damaged shingles
should never be installed.
ISSUE
DAVINCI
ACCEPTABLE
RECOMMENDS
ALTERNATIVES
Valley
Copper
28 -gauge clad metal
Flashing
Copper
28 -gauge clad metal
Eaves Flashing
Copper
28 -gauge clad metal
Nails
Non - corrosive
Hot - dipped
stainless steel
Galvanized
For questions about DaVinci Slate or its application, contact DaVinci Roofscapes ®, LLC
913 -599 -0766 or 800- DaVinci (800- 328 -4624) or www.davinciroofscapes.com
IG -SL -4/09 Please be sure to check DaVinci's website for updates. Installation Guide is subject to change without notice.
INSTALLATION
DECKING
DaVinci Slate must be installed on a smooth flat
surface; minimum 15/32" APA approved plywood
or 7/16" approved OSB. It is also necessary
that all previous roofing materials be torn
off prior to installation of DaVinci
Slate. Imperfection in the decking
may transmit through to finished roof.
DRIP -EDGE
Metal flashing is required on gable ends
and eaves. An overhanging drip edge such
as a Style "D" or Style "F" is recommended
on gable ends to help mask the rib - structure
on the underside. An overhanging drip
edge may also be used on eaves although
Style "A" or Style "B" drip edge are
acceptable options.
ICE AND WATER SHIELD (Severe
Climate Underlayment in accordance with
Chapter 15 of the UBC)
Decking
30#
felt
layer
Style D or Style F
Drip Edge can be used
In areas where the average daily temperature in January is 25° F
or lower or where ice buildup is possible, DaVinci requires ice and
water shield be installed: from the bottom edge to two feet above
the exterior wall line on all eaves, in all valleys, on all gable ends,
and around all roof projections In all cases ice and water shield is
required in all valleys, regardless of average daily temperatures or
the possibility of ice buildup.
UNDERLAYMENT
installation One layer of 30# ASTM D 226
underlayment must be installed over the entire roof in addition
to the ice and water shield.
GETTING STARTED
STARTER COURSE
Each starter tile should be installed extending past
the drip edge by approximately 1 ". However, if us-
ing Style D or Style F drip edge, the starter shingle
can be allowed to overhang less if it is appropriate
for the gutter system. The starter tiles should be
installed with the DaVinci logo on top. The starter
tiles should be spaced 3/8" apart as tiles will expand
when warm. Each starter tile should be nailed with
two nails on a line approximately 6" from the butt
and 3/" from outside edge.
Use two corrosion- resistant nails in each slate in nailing location shown on the slates. (see page 9). This includes the
roofer's choice of: copper, stainless steel or hot - dipped galvanized nails. Once the starter is in place, begin installing
slates in the lower left comer (or lower right comer for a left- handed roofer).
Two methods of installation are available: (see page 3)
1. Straight, in which the exposure of each slate is kept consistent, or
2. Staggered coursing, in which the exposure varies by a maximum 1" on adjacent shingles.
Use the alignment indicator at the top of each slate to help manage the exposure. An exposure between 6" and 71h" is
acceptable for straight courses and between 6" and 7" for staggered courses. As you progress up the roof, be careful not
to damage slates already in place. Put something, perhaps a cut slate, under toe irons (scaffolding brackets) to avoid
scratching or marring the finish of the slate already installed below.
IG -SL -4/09
INCORPORATED
PlathConstruction, Inc.
Plath Construction, Inc.
725 Chambers Avenue
Suite 13 & 14
P.O. Box 3367
Eagle, CO 81631
Phone: (970) 328 -5515
Fax: (970) 328 -5520
www.plathroofing.com
October 16, 2012
Re: 263 E Gore Creek Drive (Gorsuch tower roof)
To: TOV Department of Community Development
1. The Gorsuch roof tower will not require snow fence or snow clips because all sides of the roof will shed on
to the roofs below.
2. The current roof material has been on there for many years and is some type of plastic slate. It would take me
about 4 hours to set up the ladders to determine the exact material. If you absolutely have to know, I will do
it but hopefully this information is enough.
Please feel free to contact me if you have any questions in this regard.
Sincerely,
,' G 1g4ry TO e9 n % raW
Alberto Ortega
Vice President,
Plath Construction, Inc.