HomeMy WebLinkAboutB12-0560 ELECTRICAL LOAD CALCS
This is a Electrical Load report for the Vail Community
Development Office for the remodel at Vail Racquet Club
Building 6 Unit 1. I am the electrician working for No Bull
Contracting. My company is Eagle Electric Inc. and my
name is Michael Koenen.
The property has multable apartments. The remodel has its own meter. The
meter has a 100 amp main breaker. The feeder to the panel is a 1/0 SER wire
from the meter.
The only power requirements we are adding are 6 additional recessed
lights in the living room and dinning room. The 6 recessed cans with 22 watt
fluorescents . The change in watts is 132.
The kitchen will get new circuits for the refrigerator and microwave
to bring them up to code. They were on the existing small appliance circuits.
The kitchen will have 3 recessed lights with 22 watt bulbs total of 66
watts which is less than the fluorescent fixture with 2- 40 watt bulbs.
The kitchen counter will get 2 new pendants with 25 watt bulbs or 50
watts. Also, 2 under cabinet lights for a total of 150 watts.
The two bathrooms will have a new exhaust fans. No change in
wattage. Also new vanity fixtures with no change in wattage.
The bedroom closet will get a new switch and light to replace the pull
chain light. The bedroom will get a new fan/light to replace the old fixture.
No change in wattage.
650 sq.ft.*3VA per sq ft. 1950VA
3000VA at 100% 1950VA
General Lighting….. 1950VA
Small appliance load 3000VA
Total General lighting
And small appliance 6450VA
Range load 8000VA
New lights 200VA
Total Load 14650 divided by 240V.=61 amps
My is Michael Koenen and my company is Eagle Electric Inc.
from Box 131, Gypsum CO 471-6155