HomeMy WebLinkAboutB12-0428 NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES
,.
1CIWNOP V�II.`.
Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657
p. 970.479.2139, f. 970.479.2452, inpsections 970.479.2149
COMBINATION BLDG PERMIT Permit #: B12-0428
Project #: PRJ12-0529
Job Address: 909 RED SANDSTONE RD VAIL Applied.....: 09/08/2012
Location......: Sandstone 70 Unit C2 Issued. . . : 09/19/2012
Parcel No....: 210301401007
OWNER DAVIS, ROSS E., JR 09/08/2012
PO BOX 190
VAIL, CO
81658
APPLICANT WESTERN FIREPLACE SUPPLY 09/08/2012 Phone: 970-827-9623
910 NOTTINGHAM ROAD
AVON
CO 81620 _
License: C000003171
CONTRACTOR WESTERN FIREPLACE SUPPLY 09/08/2012 Phone: 970-827-9623
910 NOTTINGHAM ROAD
AVON
CO 81620
License: C000003171
Description:
wood to gas fireplace converstion extending gas line into
fireplace, install electrical receptical in fireplace,
install direct vent gas insert iwth full reline of existing
flue
Occupancy: Type Construction: Valuation: $3,800.00
+.........................x...=............,.....<.....,�.....,,.,,...�..,.,..... FEE SUMMARY ..........,,..............,.....>..,....,....................,..,,.............
Building Permit--=--------> $97.25 Bldg Plan Check----------> $63.21 Use Tax Fee-----------------------> $0.00
Electrical Permit---------> $115.00 Elec Plan Check-----------> $74.75 Restuarant Plan Review--------> $0.00
Mechanical Permit------> $60.00 Mech Plan Check---------> $15.00 Additional Fees-------------------->
($235.46)
Plumbing Permit--------> $15.00 Plmb Plan Check---------> $3.75 Recreation Fee--------------------> $0.00
Investigation-----------------------> $0.00
W i II Cal I------------------------------> $15.00
TOTAL PERMIT FEES--------------> $223.50
Payments-------------------------------> $223.50
BALANCE DUE------------------------> $0.00 •
......».........................>,.,.,,,.......».,.,,,.,,,...............,,...........................,.,.,........,....,,.......»...,,,.........,........>,.,...........,....,.........:
DECLARATIONS
I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure
according to the town's zoning and subdivision codes, design review approved, International Building and Residential Codes and
other ordinances of the Town applicable thereto.
REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149
OR AT OUR OFFICE FROM 8:00 AM -4:00 PM.
combination permit_012811
�
�
2
���i �� 1
.....w+.+x+�+�.wxx.+..•...w,rx+x>xxxr....�.++xx��x�.w......+xxx.:,r��x.......r+wr.x+.x+�,r�xxxx..w..+...+++s,x.�+.�....«�.�w..vw..,r�xx+��+��..xwxw...v,:r..x...+s,xx..�xxx+,r�x�ww:�xww..x.w.
CONDITIONS OF APPROVAL TO BE MET PRIOR TO FINAL SIGN OFF
Permit#: B12-0428 Address: 909 RED SANDSTONE RD VAIL
Owner: DAVIS, ROSS E., JR Location: Sandstone 70 Unit C2
.....................................................................................................................................................................................
;
combination permit_012811
.
�
�TI 11 UI 1��tL ;
..*******.....****«««.��************,,.,,*.,«**„*****�****.,.,****,.�******„*.******.,*.,***,�***«„*******�****„««„«****«*.,*********,.w,,,�**«,,,,«««««�„*****�*„**
REQUIRED INSPECTIONS AND STATUSES
Permit#: B12-0428 Address: 909 RED SANDSTONE RD VAIL
Owner: DAVIS, ROSS E., JR Location: Sandstone 70
Unit C2
«*„***,,.,*.*,,.«„*.,*.,.*.*.***„*****.***************.,«**�**,�****„*********„*******.,****,�*************,.**«*„*******,.*****«********.*****„***«.,***«*******
Item: 00120 ELEC-Rough
09/21/2012 By: mdenney Action: AP Comments:
receptacle for fireplace insert.
Item: 00200 MECH-Rough
10/01/2012 By: sgremmer Action: AP
Item: 00240 PLMB-Gas Piping
09/21/2012 By: mdenney Action: AP Comments:
tested at 15 psi.
Item: 00190 ELEC-Final
10/01/2012 By: sgremmer Action: AP
Item: 00290 PLMB-Final
10/01/2012 By: sgremmer Action: AP
Item: 00390 MECH-Final
10/01/2012 By: sgremmer Action: AP
Item: 00090 BLDG-Final
10/01/2012 By: sgremmer Action: AP
combination permit_012811
Inspection Items for B12-0428 09:14 02/05/2014
Sec Item Id Descri tion A r Re Items Action Inheritable
* 120 ELEC-Rou h Yes R 1 AP No
200 MECH-Rou h Yes R 1 AP No
' 240 PLMB-Gas Pi in Yes R 1 AP No
* 190 ELEC-Final Yes R 1 AP No
290 PLMB-Final Yes R 1 AP No
- -- -- -
390 MECH-Final Yes R 1 AP No
' 90 BLDG-Final Yes R 1 AP No
Total Rows:7
,
Page 1
Department of Community Development
75 South Frontage Road
Z Vaii, Colorado 81657
: ,�� �y-,�` . O'�� TeL• 970-479-2128;
; � . Web: www:vailgov.com
� i, _, ' Development Review Coordinator
'l'�Y,�F�# F4��t �� * � •. � � � � � . .
ti ,
. m
�' �.
-_ . _ ... _.�__ . .. . . ..;.. -:',��.+..._'�+...�.'�u.'�'�".�+'+.. ��� .. .. .. ... .... _....._�.�.'...�. ._..... ..
BUILDING PERMIT APPLICATION
(Separate applications are required for alarm &sprinkler)
Project Street A dress: 2 i�
�,.,t� /'_� Project#:
;�'�7 1 �L� Si�7 v7 D�S l UI7 E' •��C ��
(Number) (Street) (Suite#) DRB#:
Building/Complex Name: ��'/Q�'�l�f�� Building Permit#: � (L��V`�(L�"�
Lot#: Block# Subdivision:
Contractor Information
Business Name: ��v`�" ��'/�/7 ' �`� %L-�-E'� ork Class: New( ) Addition( ) Alteration�
Business Address: ��C� �11� �'z-� Type of Building: ,_
City [i C' �U State:�Zip: ��,c��) Single-Family O Duplex O Multi-Family�
` Commercial ( ) Other( )
Contact Name: � �C—!L,
Contact Phone: � ��� ���— �°Z 3 Work Type: Interior( ) Exterior( ) Both( )
Contact E-Mail: /�(.�/�.p v�//�'lL� Sif'/'�� /i�'�l`*�-� ° C-t?�� .
� Valuation of
' - Work Included Plans Included Work
Contr ctor Registration Number.
Electrical ( )Yes ( )No ( )Yes ( )No �
-,•,
X Mechanical ( )Yes ( )No ( )Yes ( )No �3�-%
Own wner's pre entative ignature(Required)_ - Plumbing ( )Yes ( )No ( )Yes ( )No '��
Project Information �� - Building ( )Yes ( )No ( )Yes ( )No
Owner Name: 1�,0� S J�V� 5 �l. _../ �
/' /ry Value of all work being performed. $ -� �
Parcel#: �I c� .� � D��r V �� O� � (value based on IBC Section 109.3&IRC Section 108.3�
(For Parcel#,contact Eagle County Assessors Office at(970-32&8640 or visit
-'� www.eaglecounty.us/patie) Electrical Square Footage
, >
Detailed Scope and Location of Work: /� �d ���2- ' �7�C-��✓�t-4�"-7 .
� -z �, °1t S��
. ; ; �;y, U�P/�(�
, ` � _
(us additional sheet if necessary �i
For Offce Use Only: Date Received:
Fee Paid: � � � � � �
Received From: D
Cash Check# SEP �� z��2
CC: Visa /MC Last 4 CC # exp date:
Auth #
TOWN OF VAIL
0�-Jan-�1
1 Listing and Code Approvals
A. Appliance Certification D. High Altitude Installations
NOTICE:If the heating value of the gas has been reduced,
MODELS: GRAND-135-C,Grand-135�P, these rules do not apply. Check with your local gas utility
SUPREME-130-C,Supreme-130-SP or authorities having jurisdiction.
LABORATORY.• Underwriters Laboratories,Inc.(UL) When installing above 2000 feet elevation:
TYPE: Vented Gas Fireplace Heater • In the USA: Reduce input rate 4% for each 1000 feet
STANDARD:ANSI Z21.88-2009 CSA 2.33-2009 above 2000 feet.
Vented Gas Fireplace Heaters • In CANADA: Reduce input rate 10% for elevations
This product is listed to ANSI standards for"Vented Gas between 2000 feet and 4500 feet. Above 4500 feet,
Appliance Heaters"and applicable sections of"Gas Burn- consult local gas utility.
ing Heating Appliances for Manufactured Homes and Check with your local gas utility to determine proper
Recreational Vehicles", and "Gas Fired Appliances for orifice size.
Use at High Altitudes".
Heat& Glo gas inserts are designed for installations into E. Non-Combustible Materials Specification
solid fuel masonry or factory built fireplaces that have been Material which will not ignite and burn. Such materials are
installed in accordance with the National, Provincial,State those consisting entirely of steel, iron, brick,tile,concrete,
and local building codes. Fireplaces are to be constructed slate, glass or plasters, or any combination thereof.
of non-combustible materials and, in the absence of local
or regional codes,meet criteria of NFPA211. No additional Materials that are reported as passing ASTM E 136,
outside air source is required. Standard Test Method for Behavior of Materials in a
Vertical Tube Furnace at 750 °C and UL763 shall be
NOTICE: This installation must conform with/ocal codes. considered non-combustible materials.
In the absence of local codes you must comply with the
National Fuel Gas Code, ANSI Z223.1-latest edition in F. Combustible Materials Specification
the U.S.A. and the CAN/CGA 8149 Installation Codes in
Canada. Materials made of or surfaced with wood, compressed pa-
per, plant fibers, plastics, or other material that can ignite
NOT INTENDED FOR USE AS A PRIMARY HEAT SOURCE. and burn, whether flame proofed or not, or plastered or
This appliance is tested and approved as either supplemen- unplastered shall be considered combustible materials.
tal room heat or as a decorative appliance. It should not be
factored as primary heat in residential heating calculations. G. Electrical Codes
B. Glass Specifications NOTICE: This appliance must be electrically wired and
grounded in accordance with local codes or,in the absence
This appliance is equipped with 5 mm ceramic glass. Re- of local codes, with National Electric Code ANSI/NFPA
place glass only with 5 mm ceramic glass. Please contact 70-latest edition or the Canadian Electric Code CSA
your dealer for replacement glass. C22.1.
C. BTU Specifications • A 120 VAC circuit for this product must be protected with
ground-fault circuit-interrupter protection, in compliance
Models Maximum Minimum Orifice
,,,p,,, ,,,P„� s,2e with the applicable electrical codes,when it is installed in
(U.S.orCanada) erwn eru�n (DMS� locations such as in bathrooms or near sinks.
US 32,000 18,000 #35
SUPREME-130-C, (0-2000 F�
Supreme-130-SP(NG) CANADA
�2000-asooF� Ze,aoo �s,zoo #ss
US 35,000 18,500 #33
GRAND-135-C, (0-2000F�
Grand-135-SP,(NG) CANADA
(2000-4500 F� 33,250 18,250 #34
US 31,000 15,500 #51
SUPREME-130-C, (�-2000 F�
Supreme-130-SP(LP) CANADA
(2000-4500FT) 2�,500 14,500 #52
US 35,000 17,000 #50
GRAND-135-C, (0.2000 F�
Grand-135-SP,(LP) CANADA
(2000-4500F� 31,000 15,500 #51
6 Heat&Glo •Grand-135-C,Grand-135-SP,Supreme-130-C,Supreme-130-SP • 2206-901 Rev.H •7/12
:�
. Department of Community Development
, � 75 South Frontage Road
�.,_.. .
Vail, Colorado 81657
• �Tel 970-47�-2'kZf�
�- .: Web:: v�nc��v �� �
Developrnent Rev� ' '���.,
x� �
. r
� . , ��'�s � r�n;,.
- .. M,�. _: ' ; ,H.�.� r� y .. ,-::
_, �:,� , �. �
,, �_ , . � ,_: .: _: ,
e� , :a
�, � v..a_- ... . �;.� ._:.°..`""1_!�.:_=„�.---` •'. �, � � - •.,w`.+.6.,>�+ '.;�CF.-.a . •
.--...�. —S�iC.._.�,...3=:. _
BUILDING PERMIT APPLICATION
(Separate applications are required for alarm & sprinkler)
Project Street A dress: p��
��yo� _�C—,� �S�f�-v� D� P /� �' �-
(Number) (Street) (Suite #)
� � —7
Building/Complex Name: ��/�'S' I"�� /�
Project #:
DRB #:
Building Permit #: � � ��V`�(� "V
Lot #: Block # Subdivision:
Contractor Information �
Business Name: �'�i'� fto/�/% ��� /�-e ork Class:
���
New ( ) Addition ( ) Alteration,�
Busmess Address. �/1 � Type of Building: __
��tY �U ' // _ State: �_ Zip: �� Single-Family ( ) Duplex ( ) Multi-Family�
c Commercial ( ) Other ( )
Contact Name: � �C—�,
Contact Phone: � 7� � U��� �Z 3 Work Type: Interior O Exterior O Both O
Contact E-MaiL• /r,(,/�GP rYj l�' i�� �/-H /'P��iG� ��T3✓J� . Valuation of
` � Work Included Plans Included Work
Contr ctor Registration Number:' '
— Electrical ( )Yes ( )No ( )Yes ( )No
X Mechanical ( )Yes ( )No ( )Yes ( )No ���
Own er's pr entative ignatOre (Required) � Plumbing ( )Yes ( )No ( )Yes ( )No �
Project Information � � � Building ( )Yes ( )No ( )Yes ( )No
Owner Name: 1`; D j S �J � 5 /. / �
Parcel #: �/� 3'— �� `t — ��— � d�% Value of all work being performed: $ ��
(value based on IBC Section 109.3 & IRC Section 108.3)
(For Parcel #, contact Eagle County Assessors Office at (970-32&8640 or visit
www.�yiecounty.us�patie) Electrical Square Footage
For Office Use Only:
Fee Paid:
Received From:
Cash Check #
CC: Visa / MC Last 4 CC #
Auth #
exp date:
Date Received:
D
� � � � V �
SEP 0 6 2p�2
'OWN OF VAIL
01-Jan-11
NOTE: THIS PERMIT MUST BE POSTED ON JOBS/TE AT ALL TIMES
,�
�w��v�,�� •
Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657
p. 970.479.2139, f. 970.479.2452, inpsections 970.479.2149
COMBINATION BLDG PERMIT Permit #: B12-0428
Job Address: 909 RED SANDSTONE RD VAIL
Location......: Sandstone 70 Unit C2
Parcel No....: 210301401007
Project #: PRJ12-0529
Appl ied.....: 09/08/2012
Issued. . . : 09119/2012
OWNER DAVIS, ROSS E., JR 09/08/2012
PO BOX 190
VAIL, CO
81658
APPLICANT WESTERN FIREPLACE SUPPLY 09/08/2012 Phone: 970-827-9623
910 NOTTINGHAM ROAD
AVON
CO 81620
License: C000003171
CONTRACTOR WESTERN FIREPLACE SUPPLY
910 NOTTINGHAM ROAD
AVON
CO 81620
License: C000003171
09/08/2012 Phone:970-827-9623
Description:
wood to gas fireplace converstion extending gas line into
fireplace, install electrical receptical in fireplace,
install direct vent gas insert iwth full reline of existing
flue
Occupancy:
Type Construction:
Valuation: $3,800.00
...................«...............,.....,,.,..............,,.,,,�..........._.,..,. FEE SUMMARY ...x..»..........,...............,.,._..,.............,..._..,......x.,,........
Building Permit -----------> $97.25 Bldg Plan Check ----------> $63.21 Use Tax Fee-----------------------> $0.00
Electrical Permit ---------> $115.00 Elec Plan Check -----------> $74.75 Restuarant Plan Review--------> $0.00
Mechanical Permit ------> $60.00 Mech Plan Check ---------> $15.00 Additional Fees--------------------> ($235.46)
Plumbing Permit --------> $15.00 Plmb Plan Check ---------> $3.75 Recreation Fee--------------------> $0.00
Investigation-----------------------> $0.00
Will Call------------------------------> $15.00
TOTAL PERMIT FEES--------------> �223.50
Payments-------------------------------> $223.50
BALANCE DUE------------------------> $0.00
........................,........,......x....,...>..�......,,.«...,..................,.,..�.........,_.......,........«..x......,..,�....,...,,...�........._........,.....................
DECLARATIONS
I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure
according to the town's zoning and subdivision codes, design review approved, International Building and Residential Codes and
other ordinances of the Town applicable thereto.
REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149
OR AT OUR OFFICE FROM 8:00 AM - 4:00 PM.
combination permit_012811
/�`
' � , �
.......................................................................x.........,............,,....,..................».,..,...,..........:....,.....................:...._............
CONDITIONS OF APPROVAL TO BE MET PRIOR TO FINAL SIGN OFF
Permit #: B12-0428
Owner: DAVIS, ROSS E., JR
Unit C2
Address: 909 RED SANDSTONE RD VAIL
Location: Sandstone 70
.......................»..,..,.............,..,......,,........,,,........,.................,.,..,,..............,,.,,.....,,................,.............,.,..,...,..........,.....,.
combination permit_012811
i
�
TQ�VN QF YAIL '
*�****„****�*,.,**..********�*********************************„******************„*****�,.***********,***********,*********,*********,*******.**.****
Permit #: 612-0428
Owner: DAVIS, ROSS E., JR
Unit C2
REQUIRED INSPECTIONS AND STATUSES
Address: 909 RED SANDSTONE RD VAIL
Location: Sandstone 70
*«******««.*..,****.*********.,**,.************««„�*****«,.**.************,.««********.******«********,,,.****.**�***************,,.,**«*„***«*.*****,.****«,.**
Item: 00120 ELEC-Rough
09/21/2012 By: mdenney Action: AP
receptacle for fireplace insert.
Item: 00200 MECH-Rough
10/01/2012 By: sgremmerAction: AP
Item: 00240 PLMB-Gas Piping
09/21/2012 By: mdenney Action: AP
tested at 15 psi.
Item: 00190 ELEC-Final
10/01/2012 By: sgremmerAction: AP
Item: 00290 PLMB-Final
10/01/2012 By: sgremmer Action: AP
Item: 00390 MECH-Final
10/01/2012 By: sgremmer Action: AP
Item: 00090 BLDG-Final
10/01/2012 By: sgremmerAction: AP
combination permit_012811
Comments:
Comments:
*****+******************************************+************************+*****************�
TOWN OF VAIL, COLORADOCopy Reprinted on 12-31-2012 at 14:41:41 12/31/2012
Statement
�*******************************************************************************************
Statement Number: R120001385 Amount: $130.00 09/19/201201:45 PM
Payment Method: Check Init: MH
Notation:
-----------------------------------------------------------------------------
Permit No: B12-0428 Type: COMBINATION BLDG PERMIT
Parcel No: 2103-014-0100-7
Site Address: 909 RED SANDSTONE RD VAIL
Location: Sandstone 70 Unit C2
Total Fees: $223.50
This Payment: $130.00 Total ALL Pmts: $223.50
Balance: $0.00
********************************************************************************************
ACCOUNT ITEM LIST:
Account Code
--------------------
EP 00100003111100
WC 00100003112800
Description Current Pmts
------------------------------ ------------
ELECTRICAL PERMIT FEES 115.00
WILL CALL INSPECTION FEE 15.00
-----------------------------------------------------------------------------
• 1
l �'3�
� 1�-"
_
- �2 c�� �
��9-27-2012 Inspection Request Re orting Page 17 �
. � r,,�
Requested Inspect Date: Friday September 28 2012
�� ��
Site Address: 909 R�D SANDSTON� RD VAIL
Sandstone 70 Unit C2
A/P/D Information
Activity: 612-0428 Type: COMBO Sub Type: AMF Status: ISSUED
Const Type: Occupancy: Use: Insp Area:
Owner: DAVIS, ROSS E., JR
Contractor: WESTERN FIREPLACE SUPPLY Phone: 970-827-9623
Description: wood to gas fireplace converstion extending� gas line into fireplace, install electrical receptical in fireplace,
install direct vent gas insert iwth full reline of existing flue
Requested Inspection(s)
Item: 290 PLMB-Final
Requestor: WESTERN FIREPLACE SUPPLY
Comments: 33 - 6
Assigned To: J N
Action: Time Exp:
Item: 90 BLDG-Final
Requestor: WESTERN FIREPLACE SUPPLY
Comments: 331-16
Assigned To: S ER
Action: Time Exp:
Item: 190 ELEC-Final
Requestor: WESTERN FIREPLACE SUPPLY
Comments: 331-166
Assigned To: SG
Action: Time Exp:
Item: 390 E -Final
Requestor: WESTE FIREPLACE SUPPLY
Comments: 33 -1
Assigned To: S R
Action: Time Exp:
Inspection Historv
Item: 120 ELEC-Rough ** Approved `"
09/21/12 Inspector: mdenney
Comment: receptacle for fireplace insert.
Item: 200 MECH-Rough
Item: 240 PLMB-Gas Piping `" Approved **
09/21/12 lnspector: mdenney
Comment: tested at 15 psi.
Item: 190 ELEC-Final
Item: 290 PLMB-Final
Requested Time: 04:30 PM
Phone: 970-827-9623
Entered By: JMONDRAGON K
Requested Time: 10:30 AM
Phone: 970-827-9623
Entered By: JMONDRAGON K
Requested Time: 09:30 AM
Phone: 970-827-9623
Entered By: JMONDRAGON K
Requested Time: 10:00 AM
Phone: 970-827-9623
Entered By: JMONDRAGON K
Action: AP APPROVED
Action: AP APPROVED
REPT131 Run Id: 14870
1 Listing and Code Approvals
A. Appliance Certification
MODELS: GRAND-135-C, Grand-135�P,
SUPREME-130-C, Supreme-130-SP
LABORATORY.• Underwriters Laboratories, Inc. (UL)
TYPE: Vented Gas Fireplace Heater
STANDARD: ANSI 221.88-2009 CSA 2.33-2008
Vented Gas Fireplace Heaters
This product is listed to ANSI standards for "Vented Gas
Appliance Heaters" and applicable sections of "Gas Burn-
ing Heating Appliances for Manufactured Homes and
Recreational Vehicles", and "Gas Fired Appliances for
Use at High Altitudes°.
Heat & Glo gas inserts are designed for installations into
solid fuel masonry or factory built fireplaces that have been
installed in accordance with the National, Provincial, State
and local building codes. Fireplaces are to be constructed
of non-combustible materials and, in the absence of local
or regional codes, meet criteria of NFPA 211. No additionat
outside air source is required.
NOTICE: This installafion must conform with local codes.
In the absence of /oca/ codes you must comply with the
National Fuel Gas Code, ANSI Z223.1-latest edition in
the U. S.A. and the CAN/CGA 8149 Installation Codes in
Canada.
NOT INTENDED FOR USE AS A PRIMARY HEAT SOURCE.
This appliance is tested and approved as either supplemen-
tal room heat or as a decorative appliance. It should not be
factored as primary heat in residential heating calculations.
B. Glass Speci�cations
This appliance is equipped with 5 mm ceramic glass. Re-
place glass only with 5 mm ceramic glass. Please contact
your dealer for replacement glass.
C. BTU Specifications
Models �Maximum MlMmum Orlflce
Input Input Slze
(U.S. orCanada) g7U/ry BTU/h (DMS)
US 32,000 18,000 �t35
SUPREME-130-C, i�'2000 Fn
Supreme-130-SP (NG) CANADA
(200Q4500 Fn 28,800 16,200 #36
US 35,000 18,500 #33
GRAND-135-C, (a-2000 Fn
Grand-13SSP, (NG) CANADA
�2000-d500 F� 33,250 18,250 #34
US 31,000 15,500 #51
SUPREMEa30-C, (a-2000 Fn
Supreme-130SP (LP) CANADA
�Z000-4500Fn 27,500 14,500 #52
US 35,000 17,000 #50
GRAND-135-C, (�-20a0 F�
Grand-135-SP, (LP) CANADA
(2000-4500F� 31,000 15,500 #51
D. High Altitude Installations
NOTICE: lf the heating value of the gas has been reduced,
these rules do not apply. Check with your local gas utility
or authorities having jurisdiction.
When installing above 2000 feet elevation:
• In the USA: Reduce input rate 4% for each 1000 feet
above 2000 feet.
• In CANADA: Reduce input rate 10% for elevations
between 2000 feet and 4500 feet. Above 4500 feet,
consult local gas utility.
Check with your local gas utility to determine proper
orifice size.
E. Non-Combustible Materials Specification
Material which will not ignite and burn. Such materials are
those consisting entirely of steel, iron, brick, tile, concrete,
slate, glass or plasters, or any combination thereof.
Materials that are reported as passing ASTM E 136,
Standard Test Method for Behavior of Materials in a
Vertical Tube Furnace at 750 °C and UL763 shall be
considered non-combustible materials.
F. Combustible Materials Specification
Materials made of or surfaced with wood, compressed pa-
per, plant fibers, plastics, or other material that can ignite
and burn, whether flame proofed or not, or plastered or
unplastered shall be considered combustible materials.
G. Electrical Codes
NOT/CE: This appliance must be electrically wired and
grounded in accorclance with local codes or, in the absence
of local codes, with National Electric Code ANSI/NFPA
70-latest edition or the Canadian Electric Code CSA
C22.1.
• A 120 VAC circuit for this product must be protected with
ground-fault circuit-interrupter protection, in compliance
with the applicable electrical codes, when it is installed in
locations such as in bathrooms or near sinks.
Heat 8 Glo • Grand-135-C, Grand-135-SP, Supreme-130-C, Supreme-130-SP • 2206-901 Rev. H• 7/12