HomeMy WebLinkAboutB12-0545 Plans Approved�
�,
L
��
c,
� ��, �
� U'
C ��
� �.
a�
� Q�
> �i
+�cn;
ih o ;
� �'
�i
Q �
�� -
�
c
.�
cLa
� �
�
� �i
r
._
�
��
Qi (
>
±�
�
�
�
Line of Existing
Accounting Office
New Duplex
Outlet, Verify
Locations, Typ.
A2
1 5/8" Light Gauge
Frame Partition
Between Offices
13'-2" Verify in Field
� �
�
2
i
Hatched Walls Indicate
New Construction, Typ
Office Manager
a� �
� �,
U �
� �
�
� �'
��
� �,
J �
� a
a� "''
� N
��
��
New 2668 Door �
to Match Existingi
�
\1 (
°. �
Switch for
Troffer Light
Line of Existing Wall, Typ.
� FLOOR PLAN �i2�� _ ��-o'�
GENERAL NOTES
Combo Phone/Data Outlet �
Verify Location in Field
�� o
� ��
�
� � Z
N� L
1.6. � O
B2 _
2
Relocated Existing
Office Door
B2 �— 3 5/8" Light Gauge
2 Frame Partition
at Outer Office
Front Desk Office
Existing Door '
to Remain `
.�..
� =� ' t
�
The Contractor and Subcontractors shall perform all work in accordance with all applicable codes, ordinances,
standards and regulations in effect within 30 days prior to commencement of the work. This includes the 2009
Edition of the International Building Code along with Town of Vail modifications to that code, as well as state
and local codes. In case of conflict between regulations, the most stringent shall apply.
Relocation of inechanical system units to be designed by the Co.ntractor, required sub-contractor or other
consultants and approved by the Owner. Alter automatic sprinkler system as required and verify with a
qualified fire protection service that the fire suppression system complies with all applicable codes.
�
C�
�
__
.�
U
�
a�
�
�
�
Q
�
�
�
rn
c
�
�X
w
0
�
�
�
�
00
0
Door Trim to
Match Existing
Accounting
Office
Existing Office
Door Relocated
to New Wall
Base Trim to
Match Existing
2 ELEVATION �i2�� _ ��-o��
�.�cit2: �._�,�LZ
i'yk�
.�� o g
BUILDING CODE INFORMATION
1 5/8" Light Gauge
Frame Partition Wall
Office Manager
Door Trim to
IUfatch Existing
New Door to
Match Existing
� � � p " � I
D
�OCT 0 9 2012
l(�I'C'� ��
TOWN C�� VAIL
Project Occupancy Groups: B— Offices
Type IB — 1 Hour Construction with Automatic Sprinkler System
New Lighting: Office Manager Area 50 Square Feet —
Lithonia Lighting, 2RTL2, 24L, 24 Watts or Equal
� /
�
" J
O
1
�
��pF CO���
,`Q� O
� tte�.�tbFFN
, �,
.:,� �,�;s� 'i1
� ��'
. •
.
, � ,.
Office Renovation Peel/Langenwalter Architects, L.L.C. date 10-5-12
David Peel, A.I.A. Kathy Langenwalter project
The Lodge Tower
200 V�il Road P.O. Box 1202 Vail, Colorado 81658 drawn KL
Vail, Colorado Phone 970-476-4506 plarch@vail.net sheet 1 of 2
Existing 2x2 Suspended
Ceiling Grid to Remain
Relocate or
Alter Extg.
Sprinkler HE
per Code—
Alter 2x2 Suspended Ceiling Grid
in Expanded Office Area as Req'd.
� .
Existing Fluorescent, Relocated
j� �i: New Smoke
counting;;Office '' Detector —
;; ;' per Code
Existing
Air Diffuser
to Remain
Existing 2x2 Suspended
Ceiling Grid to Remain
Existing
Smoke
Detector
to Remain
'I REFLECTED CEILING PLAN �i2�� _ ��-o��
Existing
Air Diffuser
to Remain
Existing -
Sprinkler
Head
Existing Fluorescent, Relocated
Front De�k Office
_ �--- Existing 2x2 Suspended
Ceiling Grid to Remain
c
.�
�
a�
�
0
�
�
rn
J
�
c
a�
U
�
N
L
�
�
�
rn
c
�
�X
w
A 1 5/8" WALL
- Existing
Smoke
Detector � �
��''.,
�.+ t��%� F` � 8 r"°'1 B V� �
�te: I a � q �, Z
�� - � d•
�dP� �— c'�� _ . . _.
-ype X 5/8" Drywall
/4" Drywall Base, One Side Only
5/8" Light Gauge Metal Framing
1/2" Sound Attenuation Blanket
-ype X 5/8" Drywall
Type X 5/8" Drywall
3 5/8" Light Gauge Metal Framing
3" Sound Attenuation Blar�ket
Type X 5/8" Drywall
B 3 5/8" WALL
WALL SECTIONS 3�� _ � �-o��
Office Renovation Peel/Langenwalter Architects, L.L.C. date 10-5-12
The Lodge Tower David Peel, A.I.A. Kathy Langenwalter project
200 Vail Road P.O. Box 1202 Vail, Colorado 81658 drawn KL