Loading...
HomeMy WebLinkAboutF12-0083 Stamped approved10 / 2 4 / 2 0 1 2 10 : 3 7 a m PR J 1 2 - 0 1 5 7 B1 2 - 0 2 2 4 F1 2 - 0 0 8 3 AUTOMATIC FIRE SPRINKLER SYSTEM EQUIPMENT SUBMITTALS FOR ONE WILLOW BRIDGE RETAIL UNIT CS2 VAIL, CO. 1. PRO DUCT NAME Vi king Ho ri zon® Mi rageTM Model B-2 Stan - dard and Quick Re sponse Con cealed Pen dent Sprin klers A. Sprin kler VK404 (Sprin kler Base Part No. 09783A) with Cover Plate Part Nos. 09804, 11225, or 11697 B. HP Sprin kler VK405 (Sprin kler Base Part No. 09782A) with Cover Plate Part Nos. 09804 or 11225 C. HP Sprin kler VK454 (Sprin kler Base Part No. 12292) with Cover Plate Part Nos. 09804, 11225, or 11697 Avail able since 1996. 2. MAN U FAC TURER The Vi king Cor po ra tion 210 N. In dus trial Park Road Hastings, Mich i gan 49058 U.S.A. Tele phone: (269) 945-9501 (877) 384-5464 Fax: (269) 945-9599 e-mail: techsvcs@vikingcorp.com 3. PRO DUCT DE SCRIP TIONVi king Ho ri zon® Mi rageTM Stan dard and Quick Re sponse Con cealed Pen dent Sprin klers are small sol der link and le ver spray sprin klers de signed for in stal la tion on con cealed pipe sys tems where the ap - pear ance of a smooth ceil ing is de sired. Ho ri zon® Mi rageTM Stan dard and Quick Re sponse Con cealed Sprin klers are hid - den from view by low-profile cover plates in stalled flush to the ceil ing. The cover plates are avail able in sev eral dec o ra tive fin ishes to meet de sign re quire ments. The two-piece de sign al lows in stal la tion and test ing of the sprin klers prior to in stal - la tion of the cover plates. Af ter the sys tem has been tested and the ceil ing fin ish ap - plied, the “push-on”, “thread-off” de sign of the cover plate as sem blies al lows easy in stal la tion of the cover plates with up to ½" (12,7 mm) ad just ment avail able. The “thread-off” fea ture is de signed to pre vent un wanted dis en gage ment of the cover as - sem blies. This fea ture also per mits tem - po rary re moval of ceil ing pan els with out tak ing the sprin kler sys tem out of ser vice or re mov ing the sprin kler. In side the body of the Ho ri zon® Mi rageTM Stan dard and Quick Re sponse Con cealed Sprin kler, the de flec tor and seal ing as sem - bly are held in po si tion by the heat-sen si - tive fus ible link. Dur ing fire con di tions, when the tem per a ture around the sprin kler ap proaches its op er at ing tem per a ture, the cover plate de taches. Con tinued heat ing of the sprin kler causes the heat- sen si tive fus - ible link to dis en gage, re leas ing the de flec - tor and seal ing as sem bly. Wa ter flow ing through the sprin kler or i fice strikes the de - flec tor, form ing a uni form spray pat tern to ex tin guish or con trol the fire. 4. TECH NI CAL DATA LIST INGS AND AP PROVALS Re fer to the Ap proval Chart on page 57 b. Spring: U.S.A. Pat ent No. 4,570,720 Thread Size: ½" (15 mm) NPT Nom i nal K-Factor: 5.6 U.S. (8,1 met ric*, for use when pres sure is mea sured in kPa). * Met ric K-Factor shown is for use when pres sure is mea sured in kPa. When pres sure is mea sured in BAR, mul ti ply the met ric K-Factor shown by 10.0. Min. Op er ating Pres sure: 7 psi (48,3 kPa) RATED WA TER WORKING PRES SURE Sprin klers VK405 and VK454 are rated for use with wa ter work ing pres sures rang ing from the min i mum 7 psi (48,3 kPa) up to 250 psi (1 724 kPa) for high-pressure sys tems. High-pres - sure (HP) sprin klers can be iden ti fied by lo cat ing the num ber “250" on the sprin kler body. Sprin kler VK404 is rated to a max i mum 175 psi (1 207 kPa) wwp. Avail able Cover Plate Ad just ment: ½" (12,7 mm) +/- 1/4" (6,35 mm) Cover Plate As sem bly Temp. Rat ings: Base Part Number 11225: 135 °F (57 °C) Base Part Number 09804: 165 °F (74 °C) Base Part Number 11697: 135 °F or 165 °F (57 °C or 74 °C) SPRIN KLER MA TE RIALS Sprin kler Body: Brass UNS-C84400 Body Cap: Brass UNS-C26000 De flec tor: Cop per UNS-C19500 De flec tor Pins: Stain less Steel UNS-S30300 But ton: UNS-C23000 H55-H80 Screw: Brass UNS-C36000 Fus ible Link As sem bly**: Nickel Al loy and Eutectic Sol der **The fus ible link of the Quick Re sponse Con - cealed Sprin kler is marked with a pur ple stripe or dot for iden ti fi ca tion pur poses only. Fus ible Link Le vers: Stain less Steel UNS-S31600 Le ver Bar: Cop per Al loy UNS-C72500 Belleville Spring Sealing As sem bly: Nickel Al - loy, coated on both sides with Tef lon Tape COVER AS SEM BLY MA TE RIALS Cover Plate As sem bly: Brass UNS- C26000 or UNS-C26800 Spring: Nickel Al loy Sol der: Eutectic AVAIL ABLE COVER FIN ISHES Part No. 11225: Pol ished Chrome Part Nos. 09804 and 11697: Bright Brass, Brushed Brass, An tique Brass, Pol - ished Chrome, Brushed Chrome, Brushed Cop per, Painted1 White (No. 1004)2, Painted1 Ivory (No. 1634)2, and Painted1 Black (No. 1007)2 1 Painted fin ish c onsists of Poly es ter Baked Enamel.2 Sherwin-Williams® Color An swers™ In te rior Color Num ber. Other col ors are avail able on re quest. See Sherwin-Williams® Color An swers™ In te rior Color Se lec tion color num bers. OR DERING IN STRUC TIONS 1. To or der Vi king Ho ri zon® Mi rageTM Stan dard and Quick Re sponse Con - cealed Pen dent Sprin klers, re fer to: A. Base Part Number 09782A or B. Base Part Number 09783A or C. Base Part Num ber 12292 2. To or der Cover As sem blies, re fer to: A. Base Part Num ber 11225 (2-3/4” di - am e ter) or 11697 (3-5/16” di am e - ter), rated 135 °F or B. Base Part Number 09804 (2-3/4” di - am e ter) or 11697 (3-5/16” di am e ter), rated 165 °F Oc to ber 10, 2003 Sprin kler 57 a TECH NI CAL DATA HO RI ZON® MI RAGETM STAN DARD AND QUICK RESPONSE CON CEALED PEN DENT SPRIN KLERS Vi king Ho ri zon® Mi rageTM Con cealed Sprin kler In stalled in Acous ti cal Ceil ing NOTE: Quick re sponse con cealed sprin klers must be in stalled in neu tral or neg a tive pres sure ple nums only. Sprin kler VK405 Sprin kler VK404 or VK454 Con cealed Sprin kler Body Con cealed Sprin kler Wrench† (Part No. 08336W/B shown.) Pro tec tive Shell † A ½" ratchet is re quired (not avail able through Vi king.) Re places page 57 a-b, dated May 2, 2003. Re fer to tech ni cal data page SR1-2 or QR1-2 for gen eral care, in stal la tion, and main te nance in for ma tion. Form No. F_012993 Fig ure 1 Note: Units of mea sure in pa ren the ses may be ap prox i ma tions. Spec ify sprin kler tem per a ture rat ing and tem per a ture rat ing and fin ish of cover plate as sem bly. AC CES SORIES Sprin kler Cab i net: Part Number 01731A Ca pac ity: six (6) sprin klers Avail able since 1971. Flush/Con cealed Sprin kler Wrenches** A. Heavy Duty Part Number 08336W/B Avail able since 1983, or B. Light Duty Part Number 10366W/B*** Avail able since 1998. **Re quires a ½" ratchet (not avail able from Vi - king). ***Ideal for sprin kler cab i nets. NOTE: Cover Plate As sem bly Part Num - ber 09804 or 11697 must be used for all Fac tory Mu tual Ap proved in stal la tions. Pre vi ous Model B-1 Cover Plate As sem bly Part Num ber 08310 may still be used for cULus in stal la tions. The cor rect Ho ri zon® Mi rageTM Con - cealed Sprin kler can be ver i fied by check - ing the fus ible link for the fol low ing iden ti fi - ca tion scheme: Stan dard Re sponse: No stripe or dot. Quick Re sponse: Pur ple stripe or dot. QREC: Yel low stripe or dot (re fer to tech ni - cal data page 87 a-c for ad di tional in for - ma tion). Oc to ber 10, 2003Sprin kler 57 b TECH NI CAL DATA Form No. F_012993 HO RI ZON® MI RAGETM STAN DARD AND QUICK RESPONSE CON CEALED PEN DENT SPRIN KLERS Ap proval Chart Ho ri zon® Mi rageTM Stan dard and Quick Re sponse Con cealed Pen dent Sprin klers Sprin kler TemperatureClas si fi ca tion Sprin kler Nom i nal Temp. Rat ing1 Max i mum Am bi ent Ceil ing Tem per a ture2 Temp. Rat ing of the Re quired Cover As sem bly Cover Plate As sem bly Base Part No.5 Or di nary 165 °F (74 °C)100 °F (38 °C)135 °F (57 °C)11225 or 11697 165 °F (74 °C)09804 or 11697 In ter me di ate 220 °F (104 °C)150 °F (65 °C)135 °F (57 °C)11697 165 °F (74 °C)09804 or 11697 Stan dard Re sponse Applications Sprin kler Base Part No.5 SIN NPT Thread Size K-Factor Maximum Wa ter Working Pres sure List ings and Ap provals4 Inches mm U.S.met ric cULus6 FM NYC7 09782A VK405 ½15 5.6 8,1 250 psi3 AW2, AY1, BY1 –AY1, BY1 09783A VK404 ½15 5.6 8,1 175 psi –AX1, AY1, AZ1 – Quick Re sponse Applications 09783A VK404 ½15 5.6 8,1 175 psi AW2, AX1, AY1, BX1, BY1 –AY1, BY1 12292 VK454 ½15 5.6 8,1 250 psi3 AW2, AX1, AY1, BX1, BY1 –AY1, BY1 Sprin kler Tem per a ture Rat ings A - 165 °F (74 °C) B - 220 °F (104 °C) Cover Plate As sem bly Temp. Rat ings W - 135 °F (57 °C) Cover Base P/N 11225 X - 135 °F (57 °C) Cover Base P/N 11697 Y - 165 °F (74 °C) Cover Base P/N 09804 Z - 165 °F (74 °C) Cover Base P/N 11697 Fin ishes of the Cover Plate As sem bly 1 - Bright Brass, Brushed Brass, An tique Brass, Pol ished Chrome, Brushed Chrome, Brushed Cop per, Painted White, Painted Ivory, and Painted Black8 2 - Pol ished Chrome Foot notes1 The tem per a ture rat ing is stamped on the sprin kler body.2 Based on NFPA-13. Other lim its may ap ply, de pend ing on fire load ing, sprin kler lo ca tion, a nd other re quire ments of the Au thor ity Hav - ing Ju ris dic tion. Re fer to spe cific in stal la tion stan dards.3 The Wa ter Working Pres sure rat ing is stamped on the sprin kler body.4 This chart shows the list ings and ap prov als avail able at the time of print ing. Other ap prov als may be in pro cess.5 Base part num ber is shown. For com plete part num ber, re fer to Vi king's cur rent price list sched ule.6 Listed by Un der writers Lab o ra tories, Inc. for use in the U.S. and Can ada.7 Ac cepted for use, City of New York De part ment of Build ings, MEA No. 89-92-E, Vol. 16.8 Other paint col ors are avail able on re quest with the same List ings and Ap provals as the stan d ard paint fin ishes. 2-1/2" (63,5 mm) ½" (15 mm) NPT 2-7/8" (73 mm) max i mum 2-3/4" (69,8 mm) or 3-5/16” (84,1 mm) for Cover 11697 2" (50,8 mm) di am e ter hole re quired, or 2-5/8” (66,7 mm) when us ing Cover 11697 2-3/8" (60,3 mm) min i mum Fig ure 2 NOTE: Upon sprin kler ac ti va tion, the de flec tor de scends to ap prox i mately 13/16" (20,6 mm) be low the sprin kler body. Tem per a ture KEY Fin ish A1X Es cutch eon (if ap pli ca ble) Re places page 57 a-b, dated May 2, 2003. Re fer to tech ni cal data page SR1-2 or QR1-2 for gen eral care, in stal la tion, and main te nance in for ma tion. Wheatland’s Schedule 40 Sprinkler Pipe is a high quality sprinkler pipe offering you the full range of assurances you require. Schedule 40 Sprinkler Pipe has passed some of the toughest lab tests ever created for sprinkler pipe. Wheatland’s schedule 40 Sprinkler Pipe is made from the highest quality steel in one of the nation’s most modern and most complete pipe manufacturing plants. Our proprietary mill coating offers you a clean, corrosion and heat resistant surface that outlasts and outperforms standard lacquer coatings. Plus, this coating can be quickly and easily painted without special preparation. Or it may be hot-dipped galvanized to meet FM requirements for dry systems in accordance with the zinc coating specifi cation of ASTM A795. Schedule 40 is also available as ASTM A 53 in NPS 1 - 6 and is UL & C-UL Listed and FM Approved. Wheatland’s Schedule 40 Standard Wall Sprinkler Pipe meets or exceeds the following: UL & C-UL Listed• FM Approved• ASTM A795, Type E, Grade A• Sprinkler Pipe Specifi cations NPS Nominal O.DNominal I.DNominal WallNominal Weight UL CRR*Pieces Lift in.mmin.mmin.mmlbs./ft.kg/m 1”1.31533.41.04926.6.1333.381.682.501.0070 1 1/4”1.66042.21.38035.1.1403.562.273.391.0051 1 1/2”1.90048.31.61040.9.1453.682.724.051.0044 2”2.37560.32.06752.5.1543.913.665.451.0030 * Calculated using Standard UL CRR formula, UL Fire Protection Directory, Category VIZY * The CRR is a ratio value used to measure the ability of a pipe to withstand corrosion. Threaded Schedule 40 steel pipe is used as the benchmark (value of 1.0). Please refer to appropriate documentation for up-to-date listing and approval information. Specifi cations and descriptions are accurate as known at time of publication and are subject to change without notice. Wheatland’s Made in the U.S.A. by Wheatland Tube Company means made to the highest standards for consistant quality. Specifi cations and Approvals 700 South Dock Street, Sharon, PA 16146 Ph 800.257.8182 Fax 724.346.7260 www.wheatland.com Wheatland Tube Company 0309 1.0Mrev02 Effective February 23, 2009 Coated Black Sprinkler Pipe Page 40 D.I. THREADED FITTINGS For fire protection services request submittal GRS 1.3 DUCTILE IRON 90 DEG. ELBOW NOMINALITEMMAX.WEIGHT SIZECODEWORKING EACH (INCH)#P.S.I.ABPIECE 1DB900335001.501.500.62 1 1/4DB900445001.751.750.90 1 1/2DB900555001.941.941.20 2DB900665002.252.251.85 DIMENSIONS DUCTILE IRON STRAIGHT TEE NOMINALITEMMAX.WEIGHT SIZECODEWORKING EACH (INCH)#P.S.I.ABPIECE 1DT3335001.501.500.85 1 1/4DT4445001.751.751.22 1 1/2DT5555001.941.941.55 2DT6665002.252.252.45 DIMENSIONS DUCTILE IRON RED.90 DEG. ELBOW NOMINALITEMMAX.WEIGHT SIZECODEWORKING EACH (INCH)#P.S.I.ABPIECE 1X1/2DB900315001.261.360.44 1X3/4DB900325001.371.450.52 1 1/4X1/2DB900415001.341.530.64 1 1/4X3/4DB900425001.451.620.72 1 1/4X1DB900435001.581.670.75 1 1/2X1DB900535001.651.800.92 1 1/2X1 1/4DB900545001.821.881.08 2X1/2DB900615001.491.881.08 2X3/4DB900625001.601.971.24 2X1DB900635001.732.021.40 2X1 1/4DB900645001.902.101.52 2X1 1/2DB900655002.022.161.65 DIMENSIONS DUCTILE IRON COUPLING NOMINALITEMMAX.DIMENSIONWEIGHT SIZECODEWORKINGEACH (INCH)#P.S.I.APIECE 1DCL0335001.670.40 1 1/4DCL0445001.930.57 1 1/2DCL0555002.150.75 2DCL0665002.531.15 DUCTILE IRON RED. COUPLING NOMINALITEMMAX.DIMENSIONWEIGHT SIZECODEWORKINGEACH (INCH)#P.S.I.APIECE 1X1/2DRC0315001.690.39 1X3/4DRC0325001.690.53 DUCTILE IRON 45 DEG. ELBOW NOMINALITEMMAX.WEIGHT SIZECODEWORKING EACH (INCH)#P.S.I.ABPIECE 1DB450335001.121.120.46 1 1/4DB450445001.291.290.73 1 1/2DB450555001.431.430.92 2DB450665001.681.681.50 DIMENSIONS DUCTILE IRON THREADED FITTINGS ARE UL, ULC LISTED AND FACTORY MUTUAL APPROVED FOR 500 PSI SERVICE. DUCTILE IRON PER ASTM A 536 GRADE 65-45- 12. DIMENSIONS CONFORM TO ANSI B16.3 CLASS 150. THREADS ARE NPT PER ANSI/ASME B1.20.1 NOTICE: DUCTILE IRON FITTINGS HAVE HIGHER TENSILE STRENGTH THEN THAT OF STEEL PIPE. THEREFORE, OVER TIGHTENING CAN CAUSE DAMAGE TO PIPE THREADS WHICH MAY CAUSE LEAKAGE. DUCTILE IRON FITTINGS SHOULD BE TIGHTENED THREE TURNS BEYOND HAND TIGHT, BUT NO MORE THAN FOUR TURNS. A