HomeMy WebLinkAboutB12-0580 load calcsElectrical Load Calculation – 163 E Gore Creek Dr. #410
930 sq ft x 3w/ft = 2790W
2 small appliance x 1500w = 3000W
Range = 8000W
Dishwasher = 1200W
Garbage disposal = 500W
Total = 15,490W
15,490W – 8000W = 7,490W
7,490W x 40% = 2,996W
2,996W + 8,000W = 10,996W (total adjusted load)
10,996W/240V = 45.8A
Existing service is 100A