Loading...
HomeMy WebLinkAboutVAIL LIONSHEAD FILING 1 BLOCK 2 LOT 1 CONFERENCE CENTER DEVELOPMENT PLAN 2005Project Name: CONFERENCE CENTER DRB Number: DR8050010 Project Description:. VAILCONFERENCE CENTER-REVIEW PROPOSED CONFERENCE CENTER MASTER PLAN AND DEVELOPMENT PLAN Participants: ARCHITECT FENTRESS BMDBURN ARCHITECTS01 I 17 12005 Phone: 303-722-5000 42l BROADWAY DENVER co 80203 Ucense: C000001802 APPLICANT TOWN OF VAIL OLILilaOO' C/O FINANCE DEPT 75 S FRONTAGE RD VAIL co 81657 ProjectAddress: 395 S FRONTAGE RD WESTVAIL Locataon: Legal Description: Lot! 1 Block: 2 Subdivision: VAIL UONSHEAD FIL 1 Parcel Number: 2101-064-0701-2 Comments! BOARD/STAFF ACTION Action: WITHDRWN Conditions: Planner: Bill Gibson ,r*m Conceptual Review Application for Design Review Department of Community Development RECHf;VED 75 South Frontage Road, Vail, Colorado 81 tel: 970.479.2139 faxi 970.479.2452 JAN 1 r 20C5 TOV.COM.DEV. building refer to the submittal requirements for the particular approval that is requested. An application for Design Review cannot be accepted until all required information is received by the Community Development Department. The project may also need to be reviewed by the Town Council and/or the Planning and Environmental Commission. Design review approval lapses unless a building permit is issued and construction commences within one year of the approval. Description of Locationof theProposal: Lot: I alock: ?,. suuoivision:Uail L,'q-oL..- d F'ltb I Physical Address:3 {s E. L,bn-s[-.^ J Cr- pa,."tuo..@ontactEag|eCo.Assessorat970-328-8640forparce|no') Zoning: Name(s)of owner(s): 4t-, u{ dc^,'l Mailing Address:5.o."d Phone: Owner(s) Signature(s): Name of Applicant:4.o.u. Mailing Address:5.it?^-'{ Phone: E-mail Address: web: www,vailgov.com General Information: All projects requiring design review must receive approval prior to submitting a (,- e-u.a^<- | (Js< Type of Review and Fee: tr ti{ E/crnceptual Review $50 Plus $1.00 per square foot of total sign area. No Fee $650 For consbuction of a new building or demo/rebuild. $300 For an addition where square footage is added to any residential or commercial building (includes 250 additions & interior conversions)' $250 For minor dtanges to buildings and site improvements, such as' reroofing, painting, window additions, landscaping, fences and retaining walls, etc. $20 For minor changes to buildings and site improvements, such as, reroofing, painting, window additions, landscaping, fences and retaining walls, etc. $20 For revisions to plans already approved by Planning Sbff or the Design Review Board. No Fee tr tr tr tr tr New Construction Addition Minor Alteration (m ulti-family/commercial) Minor Alteration (sing le-family/duple:<) Changes to Approved Plans Separauon Request f0l,f,Nm Design Review Board ACTION FORM Department of Community Development 75 South Frontage Road, Vail, Oolorado 81657 teli 970.479.2L39 fax: 970.479.2452 web: www.ci.vail,co.us ProiectName: VAILCONFERENCECENTER DRBNumber: DR8050134 Prcject Description: CONFERENCE CENTER Participants: owNER TOWN OF VAIL O4/O5l2oO5 C/O RNANCE DEPT 75 S FRONTAGE RD VAIL co 81657 APPUCANT TOWN OF VArL O4l0slz00s C/O FINANCE DEPT 75 S FRONTAGE RD VAIL co 81657 Project Address: 395 S FRONTAGE RD WEST VAIL Location: 395 E. UONSHEAD CIRCLE Legal Description: Lofi I Block 2 Subdivision: VAIL LIONSHEAD FIL 1 Parcel Number: 2101-064-0701-2 Comments: BOARD/STAFF ACTION Action: WITHDRWN Conditions: Planner: Bill Gibson I Locallon of the Proposal: Lot:.--'Block: ? subdivision:see Application for Design Review Department of Community Development 75 South Frontage Road, Vail, Colorado 81657 tel: 970,479.2139 taxi 97O.479.2452 web: www.vailgov.mm ;;d;6ih;;-1.;ffiiii""ti"qiii.rrnts for the particutar approval that is requested. An application lor Design Rwiew cannot be accepted until all required information is received by the Communily Development Oepartment' The ;;"t".i ilil'nee; i; re rwie*eopv rhe rown Councit.ani/or the.Plannins "F !gliiT111_T:T:T::,iproject may also need lo be reviewed,by ihe Town council and/or me Hlannlng ano En b"iign r"nl"", approval lapses un6si a bulldlng permit ls issued and construction commences wllhln on€ year of the aPproval. Description ol the Request:$ail' conference center run1,# General Inlormatlon: All proiects requlring design review must receive approval prior to submitting a Airii, TeV-$U,in"DFV. building permil application. Please ticle report Physlcal Address: Parcel No.: -tol (Contact Eagle Co. Assessor at 970-328-8640 for parcel no') Zonlng: Ganaral lTse Name(s) ol Owner(s): Malllng Address:75 South Frontage Road Owner(s) Slgnatu re(s) : Name of Appllcant: Pylman & Associates - Maillng Address: pO Bex 2338 Edwarde G0 81632 Phone: 9lla-47q7 E-mail Address:rickGpylnan . com Fax:949-8104 op 8q Oetl vatl CO 81657 Type of Review and Fee: . . Signs C\ Conceptual Review . New Crnstruction. Addition . Minor Alteration (m ulti-lamily/commercial) . Minor Alteralion (single-lamily/duplex) . Changes to Approved Phns . Separation Roquest $50 PtlS $1.m per square foot oi total sign area. No Fee $650 For construclion of a new building or demo/rebuild. $300 For an addition where square footage is added to any residential or commercial building (includes 250 additions & interior conversions). $250 For minor changes to buildings and site improvements, such as, reroofing, painting, window additions' landscaping, lences and relaining walls, etc. $20 For minor changes to buildings and site improvemenls, such as, reroofing, painting, window additions, landscaping, fences and retaining walls, etc, $20 For revisions to plans already approved by Planning Staff or the Design Review Board. No Fee For Offlce Use Only: C = Planning and Environmental Commission ACTION FORM Department of Community Development 75 South ftontage Road, Vail, Oolorado 81657 tel: 970.479.2139 fax: 970.479.2452 web: www,ci.vail,co.us Project Namq PEC Number: PEC050003 PEC TyPC: CONFERENCE CENTER Proiect Description: CONFERENCE CENTER Participants: ARCHmCT FENTRESS BMDBURN ARCHITECTSo1 | Ll 2005 Phone: 303-722-5000 42l BROADWAY DENVER co 80203 License: C000001802 APPUCANT TOWN OF VArL oL/t712005 C/O FINANCE DEPT 75 S FRONTAGE RD VAIL co 81657 Project Addrcss: 395 S FRONTAGE RD WEST VAIL Location: Legal Descriptaon: Loh 1 Block 2 Subdivision: VAIL LIONSHEAD FIL 1 Paroel Number: 2101-064-0701-2 Commentsi BOARD/STAFF ACTION Motion By: Seond By: Vote: Conditionsr Planner: Bill Gibson Action: WfiHDRWN Date of Apprcvat: Meeting Date: PEC Fee Paid: $650.00 Apptication for Review by the i nHg-f f;VETPlanning and Environmental Commissipn Department of Community Development 75 South Frontage Road, Vail, Colorado 81657 teli 970.479.2739 fax:. 970.479.2452 . web: www.ci.vail.co.us General Information: All projects requiring Planning and Environmental Commission review must receive approval prior to submifring a' building permit application. Please refer to the submitbl requirements for the particular approvat Urat is requestfo. An application for Planning and Environmental Commission revieu, cannot be accepted until'all required information is received by the Community Development Department. The project may also neeO to Ue reviewed by Ule T;; Council andlor the Design Revievrr Board. Type of Application and Fee: tr tr tr tr o tr trtr' Rezoning 91300 Major SuMivision 91500 Minor Subdivision $550 Exemption Plat 9650MinorAmendmenttoanSDD 91000 New Special Development District 95000 Major Amendment to an SDD $6000 Major Amendment to an SDD $1250 (no a(terior mdifrcations) Description of the $6s0 $400 $6s0 $800 $1s00 $2s0 $1300 $s00 $200 E VarianceO Sign Variance fe Location of the Physical Address: ParcelNo.:,Z, Zoning: Name(s) of Owner(s): Mailing Address: Owner(s) Signature(s): Name of Applicant: #l E-maif Addre "", TAnrLkuollra,t, ,-'-.,e., ?74-V?2 .l 'atocr: ?, subdivision: (Contact Eagh Co. Assessor at 97G328-8640 for parcel no.) JAN 1 Y 2iN5 TOV.COM.DEV. parn Hoomcaoon F."Jtff* ulllorv: Page I of 5-01/18/02 r0firNm Planning and Environmental Commission ACTION FORM Department of Community Development 75 South Frontage Road, Vail, Colorado 81657 tel: 97O.479.2L9 fax: 970.479.2452 web: www.d.vail.co.us Project Name: CONFERENCE CENTER PEC Number: PEC050004 Project llescription: CONFERENCE CENTER Pafticipants: owNER TOWN OF VArL OrlL7l2O05 C/O FINANCE DEPT 75 S FRONTAGE RD VAIL co 81657 ARCHITECT FENTRESS BMDBURN ARCHITECTSo1 | 17 12005 Phone: 303-722-5000 42l BROADWAY DENVER co 80203 License: C000001802 APPUCANT TOWN OF VAIL OrlLTlaOOs C/O FINANCE DEM 75 S FRONTAGE RD VAIL co 81657 Project Address: 395 S FRONTAGE RD WEST VAIL Location: Legal Description: Lotr 1 Block 2 Subdivision: VAIL UONSHEAD FIL 1 Parcel Number: 2101-06#0701-2 Comments: BOARD/STAFF ACTION Motion By: Second By: Vote: Conditions: Planner: Bill Gibson ActiON: WITHDRWN Date of Approval: PEC Fee Paidl $1,500.00 --E-r Rezoning Major Subdivision Minor Subdivision Exemptlon Plat Minor Amendment to an SDD New Special Development Dis$ict Major Amendment to an SDD. MaJor Amendment to an SDD (m exte rior n di fi catftn s) Parcel No.: Zoning: Name(s) of Owner(s): Malling Addressl Owner(s) Signature(s): Name of Applicant: Malllng Address: of the Location of the : Lot: ,l 'Bbck: ?. subdivision: (Contact Eagle Co, Assessor at 970-328-8640 for parcel no.) Hl Application for Review by the Planning and Environmental Commi Department of Community Development 75 South Frontage Road, Vail, Colorado 81657 tel: 970.479,2t39 tax:. 970.479.2452 . web: www.d.vail,co.us General fnformation: All projects requiring Planning and Environmental Commission review must receive approval prior to submifring a . building permit application. Please r€'fier to the submittal requlrements for the pardorlar apprwal that is requested. An applicatlon for Planning and Environrnental Commission revlew @nnot be accepted until all reguired information is received by the Community Development Departnent. The project may also need to be revieMved by the Touen Council and/or the Design Revial Board. Type ofApplicadon and Fee: $1300 $1500 $6s0 $6s0 $1000 $6000 $6000 $12s0 C. Floodplain Modificathn Minor ExErior Alteration JAN 1 ? ZiJ$5 TOV.COM.DEV. D tr tr tr tr tr tr tr tr tr $6s0 $400 $650 $800 $1s00 $2s0 $1300 $s00 $200 elopment Plan tr LJ tr Varianae Sign Variance E-mail Address: For Office Use Oqly: Fee Paid:lpptication-bfte '.1L PEC No,: Page I of5-01/18/02 I ,*ffi Planning and Environmental Commission ACTION FORM Department of C.ommunity Development 75 South Frontage Road, Vail, Colorado 81657 tel: 970.479.2L39 fax: 970.479.2452 web: wrvw.ci.vail.co.us Project Name: CONFERENCE CENTER PEC Number: PEC050017 Project Description: MASTER PLAN AMENDMENTS Participants: owNER TOWN OF VArL 0310L12005 CIO FINANCE DEPT 75 S FRONTAGE RD VAIL co 81657 APPLICANT Pylman & Associates, Inc. 03/01/2005 Phone: 97 0-9494797 Attn: Rick Pylman P.O. Box 2338' Edwards co 81632 ProjectAddress: 395 S FRONTAGE RD WESTVAIL Locationr Legal Description: [ot: 1 Block 2 Subdivision: VAIL LIONSHEAD FIL 1 Parcel Number: 2101-064-070L-z 2101-064-0000-3 Commentsl BOARD/STAFF ACIION Motion By: Second By: Vote: Conditions: Planner: Bill Gibson Action: WITHDRWN Date of Approval: PEC Fee Paid: $0.00 l, ,rt.m APPlication for Review bY the Planning and Environmental Commission $650 $20o $650 $800 $1500 $250 $1300 --'-ft qrt Deparlment of Community Developmenl 75 South Frontage Road, Vail, Colorado 8'|657 rel: 970,479.21 39 lax' 970'479.2452 web: www.vajlgov'com General lntormation: All projects requiring Planning and Environmental commission review must receive approval prior to submitting a building permit application. itease reter to the submittal requirements lol.the particular €pproval that is requested An application for Planning and Envilonmental commission revlew cannot be accepted until all requjred inlormation is received by the Commun,rv o*"i"pt"ti'bepartm"nt. The proiect may also need to be reviewed by the Town Council and/or the Design Review Board. Type ot Application and Fee: variance $5oo Sign Variance $200 Rezoning $1300 Major Subdivision $1500 Minor subdivision s65o New Sp€cial Development Dislrict $6000 Major Amendment to an SDD $6000 Maior Amendment to an SDD $1250 ho e xterior mo di f icat io ns ) Description of the Request: Adoptl-on of Master Plan Location of flre p,oeo".l: Lol: I Block: 2 Subdivision:- Vall/Lionshead lst Fl1ing & Physicatlddtccsl Lot 3. A Resubdivision of Lot l, Block l, Vail/Lionshead 2nd Fi1lng (Contact Eagle Co. Assessor at 970-328-8640 for parcel no') Conditional Use Permit Floodplain Modification Minor Exterior Alteration Major Exterior Alteration Developmenl Plan Amendment to a DeveloPment Plan Zoning Code Amendment I Parcel No.: Malllng Address:Phone: 970-479-2138 Zoning:General Use Name(s)of Owner(s): Town of Vail Owner(s) Slgnalure(s) : Name of Applicant: MallingAddress: P.O. Box 2338, Edwards' CO 81632 _ Phone: q7O-q4q-t1797 E-mall Address: rickpylman.com Fax 970-949-8104 Projecr No.: pRfgf - oeel - Page lofT-04i01l04 IOI4/1VM Planning and Environmental Commission ACTION FORM Department of Community Development 75 South Frontage Road, Vail, oolorado 81657 tel: 970.479.2139 fax: 970.479.2452 web: www.ci.vail.co.us Prcject Name: PEC Number: PEC050025 PECType: CONFERENCE CENTER Proiect llescription: CONFERENCE CENTER Participants: owNER TOWN OF VAIL O4/05l2OOs C/O FINANCE DEPT 75 S FRONTAGE RD VAIL co 81657 APPUCANT TOWN OF VAIL O4l05l2OO5 C/O FINANCE DEPT 75 S FRONTAGE RD VAIL co 81657 Project Address: 395 S FRONTAGE RD WEST VAIL Location: Legal DescripEon: Lot: 1 Block 2 SuMivision: VAIL LIONSHEAD FIL 1 Parcel Number: 2101{64-0701-2 Comments: BOARD/STAFF ACTION Motion By: Second By: Vote! Conditions: Planner: Bill Gibson Action: WITHDRWN Date of Approval: Meeting Date: PEC Fee Paid: $650.00 "Tl.),;-$'.,;!l-DEV. General lnformation: All projects requiring Planning and Environmental Commission review must receive approval prior to submitting a building permit applicatlon, Please refsr to the submittal requiremenls tor the particulai approval that is requested. An applicalion for Planning and Environmental Commission review cannol be accepted until all required intormation ! received by the Community Development Depa.lment. The project may also need to be reviewed by the Town Council and/or the Design Review Board. Type ol Appllcatlon and Fee: Flezonjng $1300 Major Subdivision $tsO0 Minor Subdivisron $650 Exemption Plat $650 Minor Amendment to an SDD $1000 New Special Develophenl District $6000 Major Amendment to an SDD $6000 IVlajor Amendment to an SDD $1250 ( n o e xt e ri or mod i f ications) T5South Frontage Road, Vail, Colorado 81657 tel: 970.479.2139 tax: 970.479.2452 webr www.vailgov.com r) Conditional Use Permit)- FloodplainModification. Minor Exterior Alteration. Major Exterior Alteration. Development Plan. Amendment to a Developrnent Plan. Zoning Code Amendment. Variance. Sign Variance $650 $400 $650 $800 $1500 $2s0 $1300 $500 $200 a,$nn} TZvl 8 Nttf Description of the Request:Condltlonal Use Permlt for Vall Conference Center on Charter Bus Lot Locallon of the Proposal: Lot: _ Block: Subdivision: char-rer- Rrrs r.r'r Physlcal Address: Parcel No.:(Contact Eagle Co. Assessor at 970-328-B640 lor parcel no.) Zoning:General Use Name(s) of Owner(s):Town of Vall MalllngAddress: 75 S. Fronraee Road Vail . CO 81657 _ Phone: 479-2105 Owner(s) Slgnatu re(s) : Name of Appllcant: Pylman and Assoclaces, Inc. MaillngAddress: P 0 Box 2338 Edwards. C0 816:Z Phone: 949-t+7 97 E-mail Address: rlck€pylman.com Fax 949-8104 For Offlce Use Onlv: Fee Pau:b;"' Crd!'glli" ---- *3t Page I of5-04/01/04 TOI,[NM Planning and Environmental Commission ACTION FORM Department of Community Development 75 South Frontage Road, Vail, Colorado 81657 tel: 970.479.2L39 fax: 97O.479.2452 web: wwwci.vail.co.us Project Name: PEC Number: PEC050026 PECType: CONFERENCE CENTER Project Description! UONSHEAD PARKING STRUCTURE Participants: owNER TOWN OF VAIL O4lOSl2OOs gO FINANCE DEPT 75 S FRONTAGE RD VAIL co 81657 APPUCANT TOWN OF VArL 0410512005 C/O FINANCE DEPT 75 S FRONTAGE RD VAIL co 81657 Project Address: 395 S FRONTAGE RD WEST VAIL Locataon: t-egaf Description: Lot: 1 Block: 2 Subdivision: VAIL LIONSHEAD FIL 1 Parcel Number: 2l0L-064-070I-2 Comments: BOARD/STAFF ACTION Motion Byl Second By: Vote: CondiUons: Planner: Bill Gibson Action: WITI-IDRWN Date of Approval: Meeting Date: PEC Fee Paid: $650.00 IOI,I/N OT I'XI Application for Review bY the Planning and Environmental Commi Deparlrnent of Community Developlnenl 75 South Fronlage Foad, Vail, Colorado 81657 tel: 970.479.21 39 tax. 910.479 2452 web: www.vailgov.com ffi)n l,i' ' General Information: All projects requiring Planning and Environmental Commission review musl (eceive approval prior to submitling a building permat application. please reler to the subrnittat requirements for the particular approval that is requested' An application loi planning and Environmental Commlssion r€view cannol be accepted untll all required informalion is recetved by the Community Development Department. Th€ proiecl may also need to be reviewed by the Town Councrl and/or the Design Review Board. Type ol Application and Fee: Rezoning $1300 Maior SuMivision $1500 Mir-ror Subdivision $650 Fxemption Plat $650 Minor Amendment to an SDD $1000 Nev/ Special Development District $6000 Maior Amendment to an SDD $6000 Maio. Amendment to an SDD $1250 (no exterior modif ications) Conditional Use Permit FloodDlain Modaticatioll Minor Exterior Alteration Maior Exterior Alteration Development Plan Amendmenl 10 a Devetopment Plan Zoning Code Amendment Varaance Sign Variance $q B s $650 $400 $6s0 $800 $ 1500 $250 $1300 $s00 $200 Description ol the Request: Conditional Use Pe ---r--- Location of the Proposaf : Lot: d etoct<: Z Subdivision:Lkt-'l (-td.'[^-'-a t Physical Address: parcef No.: ltQ( Obqaq+,ontacr Eagte Co. Assessor at 970-328-8640 for parcelno.) ZOnlng: - Celaral Uce Name(s) of Owner(s): Tor.m of ve11 MailingAddress: 75 S. Frontage Road Vall, Co R1657 - Phone: a7q-? I 0q Owner(s) Signature(s) : Name of Applicant: P 0 Box 2338 Edwards. CO 81632Mailing Address: Phone: 949-4797 Fax-949-B 104E-mail Address: Pagc Iol 5-t)4^Il K\4 rlckGpylman, com tt TO: FROM: DATE: SUBJECT: MEMORANDUM Planning and Environmental Commission Community Development Department June 13,2005 A request for a correction to the Vail Land Use Plan to designate the Lionshead Redevelopment Master Plan Area and an amendment to the Lionshead Redevelopment Master Plan to amend, in part, Chapter 5, Vail Civic Center Detailed Plan Recommendations, and setting forth details in regard thereto; and, a request for a final review of a conditional use permit, pursuant to Section 12-gC-3, Conditional Uses, Vail Town Code, to allow for a public convention facility and public parking facilities and structures, located at 395 East Lionshead Circle/Lot 1, Block 2, Vail Lionshead Filing 1, and setting forth details in regard thereto. Applicant: Town of Vail, represented by Pylman & Associates, Inc. Planner: Bill Gibson il. SUMMARY The applicant, Town of Vail, represented by Pylman & Associates, Inc., has requested a worksession meeting with the Planning and Environmental Commission to provide an introduction to the Conference Center project located at the "Charter Bus Lot" site adjacent to the Lionshead Parking Structure. The purpose of this worksession is to allow the applicant to present an overview of the project hislory/background and the submitted development review applications. This worksession meeting is the first of many meetings to be held over the next several months intending to facilitate the development review process for the submitted development review applications. The Commission is not being asked to take any formal actions at this time. DESCRIPTION OF THE REQUEST The applicant, Town of Vail, represented by Pylman & Associates, Inc., is requesting a worksession meeting with the Planning and Environmental Commission to discuss the proposed plans for the Conference Center project, located at the "Charter Bus Lot" site adjacent to the Lionshead Parking Structure. The purpose of this meeting is to allow the applicant an opportunity to present an introduction/overview of the proposed project and to provide a brief description of the development review applications that have been submitted to facilitate the development of the Conference Center project. The scope of this project will encompass three principle components: . New conference center facilityr Lionshead Parking Structure renovations. South Frontage Road and East Lionshead Circle streetscape improvements This project will require the Planning and Environmental Commission's review and approval of the following development review applications: o Text Amendments to the Lionshead Redevelopment Master Plan. Conditional Use Permit for a public convention facility. Conditional Use Permit for public parking facilities and structures The proposed Conference Center project falls within the purview of the Lionshead Redevelopment Master Plan. The Lionshead Redevelopment Master Plan is a comprehensive guide that outlines goals, objectives, and recommendations for the development and redevelopment of the Lionshead neighborhood. The proposed Conference Center project's adherence to the policies and recommendations of the master plan should be a significant factor in the Planning and Environmental Commission's evaluation of the submitted development applications. Excerpts from the Lionshead Redevelopment Master Plan relevant to the Conference Center proposal have been identified in Section V of this memorandum. Chapter 2 of the Lionshead Redevelopment Master Plan identifies the Town of Vail's policy objectives for the redevelopment of the Lionshead neighborhood. Chapter 3 of the Lionshead Redevelopment Master Plan provides an assessment of the existing conditions within Lionshead the Lionshead neighborhood. Chapter 4 and Chapter 5 provide general and specific recommendations for the future developmenUredevelopment of Lionshead. A portion of Chapter 5 specifically addresses the "Vail Civic Center' area which contemplates a future conference center. Chapters 6, 7, and 8 provide site design guidelines, design standards, and architectural design guidelines for Lionshead; and finally Chapter 9 addresses implementation of the master plan. A portion of Chapter 9 specifically addresses the "Vail Civic Center" area and future conference center. The applicant is proposing to amend the Lionshead Redevelopment Master Plan to update the document as it relates to the proposed Conference Center project. The adoption of any such amendments will require Planning and Environmental Commission review and recommendation to the Town Council. The Lionshead Parking Structure and Charter Bus Lot site is zoned General Use (GU) District. Within the General Use District, public convention facilities and public parking facilities and structures are allowed as conditional uses. Therefore, both the proposed conference center facility and the proposed modifications to the Lionshead Parking Structure require Planning and Environmental Commission review and approval of a Conditional Use Permit. ilt. tv. Additionally, within the General Use District all development standards are determined by the Planning and Environmental Commission. Therefore, the proposed conference center facility and the proposed modifications to the Lionshead Parking Structure require Planning and Environmental Commission review and approval of a site specific development plan. This worksession meeting is the first of many meetings to be held over the next several months intending to facilitate the development review process for the submitted development review applications. As this worksession is only intended as an introduction to the Conference Center project, the Commission is not being asked to take any formal actions at this time. Future worksessions will be held to review the individual development applications and details of the proposed Conference Center project. A vicinity map (Attachment A), a Town Council memorandum date June 7, 20Os (Attachment B), Lionshead Redevelopment Master Plan excerpts (Attachments C, D, E, F, and G), the applicant's draft project master plan (Attachment H) have all been attached for reference. BACKGROUND A brief history of the proposed Conference Center project is outlined in an attached memorandum to the Town Council dated June 7,2OO5, (Attachment B) and in the Applicant's Draft Project Master Plan (Attachment H). ROLES OF THE REVIEWNG BOARDS The purpose of this section of the memorandum is to clarify the responsibilities of the Design Review Board, Planning and Environmental Commission, Town Council, and staff on the submitted applications: A. Lionshead Redevelooment Master Plan Amendment Order of Review: Generally, master plan amendment applications will be reviewed by the Planning and Environmental Commission and the Commission will forward a recommendation to the Town Council. The Town Council will lhen review the amendment application. Planning and Environmental Gommission: The Planning and Environmental Commission is responsible for the review of a Lionshead Redevelopment Master Plan amendment application, pursuant to Section 2.8, Adoption and Amendment of the Master Plan, and forwarding of a recommendation to the Town Council. Design Review Board: The Design Review Board has no review authority over a master plan amendment. Town Council: The Town Council is responsible for final approval, approval modifications, or denial of a Lionshead Redevelopment Master ? with Plan amendment application, pursuant to Section 2.8, Adoption and Amendment of the Master Plan. The Town Council has the authority to hear and decide appeals from any decision, determination, or interpretation by the Planning and Environmental Commission and/or Design Review Board. The Town Council may also call up a decision of the Planning and Environmental Commission and/or Design Review Board. Staff: The Town Staff facilitates the application review process. Staff reviews the submitted application materials for completeness and general compliance with the appropriate requirements of the Town Code. Staff also provides the Planning and Environmental Commission a memorandum containing a description and background of the application; an evaluation of the application in regard to the criteria and findings outlined by the Town Code; and a recommendation of approval, approval with modifications, or denial. B. Conditional Use Permit (CUP) Order of Review: Generally, conditional use permit applications will be reviewed by the Planning and Environmental Commission, and then any accompanying design review application will be reviewed by the Design Review Board. Planning and Environmental Gommission: The Planning and Environmental Commission is responsible for final approval, approval with modifications, or denial of a conditional use permit application, in accordance with Chapter 12-16, Conditional Use Permits, Vail Town Code. Design Review Board: The Design Review Board has no review authority over a conditional use permit or variance application. However, the Design Review Board is responsible for the final approval, approval with modifications, or denial of any accompanying design review application. Town Council: The Town Council has the authority to hear and decide appeals from any decision, determination, or interpretation by the Planning and Environmental Commission and/or Design Review Board. The Town Council may also call up a decision of the Planning and Environmental Commission and/or Design Review Board. Staff: The Town Staff facilitates the application review process. Staff reviews the submitted application materials for completeness and general compliance with the appropriate requirements of the Town Code. Staff also provides the Planning and Environmental Commission a memorandum containing a description and background of the application; V. an evaluation of the application in regard to the criteria and flndings outlined by the Town Code; and a recommendation of approval, approval with modifications, or denial. APPLICABLE PLANNING DOCUMENTS Title 12. Zoninq Requlations. Vail Town Gode Article 12-9C: GeneralUse (GU) District(in part) 12-9C-1: PURPOSE: The general use district is intended to provide sites for public and quasi- publlc uses which, because of their special characteristics, cannot be appropiately regulated by the development sfandards prescribed for other zoning districts, and for which development standards especially prescribed for each particular development proposal or proiect are necessary to achieve the purposes prescribed in section 12-1-2 of this title and to provide for the public welfare. The general use disfrlcf ts intended to ensure that public buildings and grounds and certain types of quasFpublic uses permitted in the district are appropriately located and designed to meet the needs of residenfs and visitors to Vail, to harmonize with sunounding uses, and, in the case of buildings and other structures, to ensure adequate light, air, open spaces, and other amenities appropriate to the permifted types of uses. 12-9C-3: CONDITIONAL USES; (in part) A. Generally: The following conditional uses sha// be permifted in the GU district, subject to issuance of a conditional use permit in accordance with the provisions of chapter 16 of this tifle: Public parking facilities and structures. Public theaters, meeting rooms and convention facilities. 1 2-9 C-5: D EV ELO P MENT SIANDARDS; A. Prescribed By Planning And Environmental Commission: ln the general use district, development standards in each of the following categoies shall be as prescribed by the planning and environmental commission: 1. Lot area and site dimensions. 2. Setbacks. 3. Building height. 4. Densig control. 5. Site coverage. 6. Landscaping and site development. 7. Pa*ing and loading. B. Reviewed By Planning And Environmental Commission: Development standards shall be propsed by the applicant as a part of a conditional use permit application. Site specifrc development standards shall then be determined by the planning and environmental commission during the review of the conditional use request in accordance with the provisions of chapter 16 of this title. 1 2-9 C-6: ADD I TI O NAL DEV ELO P MENT SIANDARDS: Additional regulations pertaining to site development standards and the development of land in the general use district are found in chapter 14 of this title. Chapter 12-16: Conditional Use Permits (in part) 1 2-1 6-1 : PURPOSE: Ll MITATIONS: ln order to provide the flexibility necessary to achieve the objectives of this tifle, specified uses are permitted in certain dlsfnbts subject to the granting of a conditional use permit. Because of their unusual or special characteristics, conditional uses require review and evaluation so that they may be located properly with respect to the purposes of this title and with respect to their effects on surrounding properties. The review process prescribed in this chapter is intended to assure compatibility and harmonious development between conditional uses and sunounding properties and the town at large. Uses /isfed as conditional uses ln fhe various dlsfricfs may be permifted subject to such conditions and limitations as fhe town may prescribe to ensure that the location and operation of the conditional uses will be in accordance with development objectives of the town and will not be detrimental to other uses or properties. Where conditions cannot be devised to achieve these objectives, applications for conditional use permits shall be denied. Lionshead Redevelopment Master Plan CHAPTER 2: INTRODUCTION (in part) 2.1 Purpose of the Master Plan This master plan was initiated by the Town of Vail to encourage redevelopment and new development initiatives within the Lionshead study area. Both public and private lnteresfs have recognized that Lionshead today lacks the economic vitality of Vail Village, its neighboring commercial district, and fails to offer a world c/ass resorf experience. Lionshead's economic potential has been inhibited by a number of recunent themes: lack of grov,rth in accommodation units ("hot beds"), poor retail qualtty, the apparent deterioration of existing buildings, an uninteresting and disconnected pedestrian environment, mediocre architectural character, and the absence of incentives for redevelopment. Redevelopment is citical for Vail and Lionshead if the community is to remain a competitive four-season resort. Other resorts are spending millions of dollars to upgrade their facilities in order to attract more visifors year-round. Grovvth in the number of skiers annually has slowed to one to two percent, intensifying competition for market share. Skiers are spending /ess tme skiing and more time shopping, dining out, and enjoying other off-mountain activities. As a result, the demand for quality retail shopping and a greater diversity of expeiences has dramatically increased. All of these are sorely in need of improvement in Lionshead. Vail, and specifically Lionshead, will fall behind if the community fails to upgrade the quality of its facilities and correct the existing flaws in its primary commercial nodes. This master plan, developed over a period of two years and with extensive involvement by the community, is a comprehensive guide for property owners proposing to undertake development or redevelopment of their properties and the municipal officials responsible for planning public improvements. The plan outlines the Town's objec1ves and goals for the enhancement of Lionshead and proposes recommendations, incentives, and requirements for redevelopment and new development of public and pivate propefties. lt also recommends specifrc public improvement projects that are strategically important to the future success of Lionshead. The master plan is intended to provide direction over the next 15 to 2O years. 2.2 Definition of a Master Plan ln the development of the Lionshead Master Plan, the following definition has been used as fhe basrs for this work: A master plan is a guide, a flexible framework for future action. lt articulates a community's fundamental land use policies, principles, and goals in a broad and general way. lt plans for the future physical development or redevelopment of an area of the community, including its functional and circulation sysfems and its public facilities. The land use policies in a master plan are generally implemented through zoning ordinances. Existing zoning and land use codes may be modified and new provisions enacted in order to conform to the master plan and carry outthe plan's objecfues. A master plan does not convey approvat for particular development proposals or concepts, nor can it be implemented in a short time frame. After adoption of the Lionshead Master PIan, every development proposal will have to go through the applicable development review and approval process, with its attendant public notices and public hearings. A proposal's adherence to the policies contained in the adopted master plan will be one of the factors analyzed by staff, the Planning and Environmental Commission (PEC), the Design Review Board (DRB), and the Town Council (as applicable) in determining whether to approve or disapprove the specific proposal. 2.3 Policv Obiectives The Town Council adopted six policy objectives on November 4, 1996 to outline the important issues fo be addressed in the master plan and to provide a policy framework for the master planning process. 2.3.1 Renewal and Redevelopment Lionshead can and should be renewed and redeveloped to become a waffner, more vibrant environment for guests and residents. Lionshead needs an appealing and coherent identity, a sense of place, a personality, a purpose, and an improved aesthetic character. 2.3.2 VitalQ and Amenities We must seize the opportunity to enhance guest expeience and community interaction through expanded and additional activities and amenities such as performing arts venues, confercnce facilities, ice inks, sfreefscape, parks and other recrea$onal improvements. 2.3.3 Strcnger Economic Base Through lncreased Live Beds ln order to enhance the vitality and viability of Vail, renewal and redevelopment in Lionshead must promote improved occupancy rates and the creation of additional bed base ("live beds" or "warm beds") through new lodging products. 2.3. 4 lmproved Access and Circulation The flow of pedestrian, vehicular, bicycle and mass transit traffic must be improved within and through Lionshead. 2. 3. 5 I m proved I nfrastructu re The infrastructure of Lionshead (streetg wall<ways, transportation sysfemg parking, utilities, loading and delivery sysferng snow removal and storage capacity) and its public and private sellces must be upgraded to support redevelopment and revitalization efforts and to meet the seruice expectations of our guests and residents. 2.3.6 Creative Financing for Enhanced Private Profits and Public Revenues Financially creative and fiscally realistic strafegr'es must be identified so that adequate capital may be raised from all possible sources to fund desired pivate and public imprcvements. 2.4 Ground Rules for the Master Plannino Process On November 4, 1996, the Town Council adopted the following ground rules for the master planning process in order to clarify the initial parameters and rules under which the master plan would be developed. 1. The master plan to be developed for all public and private lands in Lionshead will serue as fhe policy framework for all future decision- making on specific development and redevelopment proposals in Lionshead. The master plan will be based on the Lionshead Policy Objectives adopted by the Town Council to reflect the community's nferesfs. 2. The Town of Vail will work collaboratively with Vail Resofts, lnc. on the master plan for Lionshead and will involve all other interested citizens, busrness owners and property owners in the master planning process. The master plan ultimately recommended may or may not reflect development apprcaches cunently being explored by VRl. 3. Proprietary information of any private property owner or developer will remain private and confidential unless it becomes part of a public record. 4. There will be no nef /oss to the Vail community of either locals' housing or parking spaces (public and private) now existing in Lionshead. 5. Collaborative public/private redevelopment and financing ventures, including urban renewal authorities and downtown development authorities, will be considered. 6. The intent of redevelopment includes minimizing short-term construction-related impacts of redevelopment on existing businesses and residents and increased cooperation between the public and pivate sectors. The Town Council will have final decision-making authority on the Lionshead Master PIan, adoption of implementing actions, use of public lands, public improvements, and public financing mechanisms. The Town Council or its authorized boards (PEC and DRB) will make final decrsions on subsequent site-specific development proposa/s consisfenf with the master plan. 2.5 Urban Desiqn Principles On November 4, 1996, the Town Council adopted the following set of urban design principles to guide the development of the master plan: 1. Connect Lionshead physically and visually to the mountain landscape. 2. Make people physically and emotionally comfortable in Lionshead. 3. Provide a sense of arrival to demarcate the Lionshead districL 4. Create landmarks and turning points to guide people through the area and make it memorable. 5. Provide gates and portals to help define the sequence of public spaces and places. 6. Define appropriate /and uses adjacentto outdoor spaces. 2.8 Adoption and Amendment of The Master Plan The Lionshead Master Plan was adopted by resolution No. 14, Series of 1998, on December 15t', 1998, by the Vail Town Council following a recommendation to approve by the Planning and Environmental Commission. Future amendments to this master plan must be approved by resolution or motion by the Town Council following a formal recommendation by the Planning and Environmental Commission. lmplementation activities and ordinances will be approved in accordance with the Town of Vail Municipal Code. CHAPTER 3: EXISTING CONDITIONS ASSESSMENT AND PROBLEM IDENTIFICATION (in part) 3.2 Existinq Land Uses 3.2.4 Conference/Meeting Facilities The Lionshead study area contains several public and private conference facilities (see Map L), with the majority of space in private ownership. Aside from Dobson ice arena, which is not suitable for smaller conferences and meetings, the only publicly available conference room in Lionshead is in the Vail Public Library, a small and heavily utilized facility. ln general, there is a growing need for additional conference space in Lionshead, especially as the local economy seeks to diversify and provide a wider range of destination resort activities in addition to skiing. 3.8 Transportation and Circulation During Presrdenf's Day weekend in 1997 the transportation planning firm of Felsburg, Holt, and Ullevig conducted an in-depth inventory and analysis of the existing transpoftation pattems in the Lionshead study area. Their report is contained in appendix A. The following is an overview of the existing transportation and circulation systems in Lionshead: 3.8.1 Vehicular The vehicular access sysfem in Lionshead is compised of one primary route (the l-70 South Frontage Road) and four secondary roufes (Easf Lionshead Circle, West Lionshead Circle, Lionshead Place, and Forest Road). 3.8.1.1 l-70 South Frontage Road The l-70 South Frontage Road (see figure 3-B) borders the northern edge ofthe study area and provides vehicular access for all of Lionshead. General rssues assoclafed with the frontage road are described below: a. Bicycles and Pedestrians There are no continuous bicycle paths or lanes along the South Frontage Road nor are there adequate shoulders that bicyclists or pedestrians could use instead. The need for a bicycle lane was documented in the 1991 Vail Transportation Master Plan and the 1988 recreation trails masterplan. The pedestrian core of Lionshead is an obstacle to bike traffic through Lionshead to Vail Village, forcing bikes to take the frontage road instead and causing dangerous conflicts between cycllsts and motoists. 10 b. Turning Movements There is one eastbound and no westbound tuming lanes from the frontage road into Lionshead, which results in traffic backup during peak travel periods. Westbound vehicles often veer onto the gravel shoulder to pass cars waiting to make a left turn. As Lionshead redevelops and expands ifs bed base, this problem will intensify. c. Directional Signage Vrsifors to Lionshead often complain of difficulty finding their destination. Bewildered mofonsfs slow down at each intersection because there is no signage directing them to their lodgings. The cumulative effecfs are traffic congestion and iritated guests. d. Overflow Parking. Each winter during peak ski weekends the westbound shoulder of the frontage road becomes a default overflow parking area, stretching westward from the turn across from the Evergreen Lodge to the entry of the Vail Associafes seruice yard. This situation creates a dangerous conflict between through-traffic and pedestrians, as there are no delineated crosslngs and no sidewalk on the south side of the frontage road. Safe crossings are made even more difficult by winter road conditions and traffic congestion and because pedestrians are often wearing ski boofs and carrying skis. 3.8.1.2 East Lionshead Circle East Lionshead Circle (see figure 3-9l serues four primary purposes.' a) providing access to eight lodging facilities; b) serving as the transit route for private shuft/es and the public bus sysfem; c) accommodating loading and delivery functions; and d) providing a place for private skier drop-off. a. Lodging Access East Lionshead Circle accesses four lodge properties west of the main bus drop-off/ pedestrian crossing and four others to the east of the bus stop. Vehicular traffic to the four properties to the east poses a srgrni/?cant conflict with the large volume of pedestrian traffic crossing from the western end of the parking structure into the Lionshead core. The southern edge of East Lionshead Circle is fragmented by four separate curb cuts accessrhg the Lodge at Lionshead. b. Transit Transit traffic on East Lionshead Clrcle conslsfs of Town of Val buses as well as local and regional shutUe bus traffic. Town buses have difficulty making a left turn from East Lionshead Circle to the west-bound lane of the South Frontage 1l Road because of the street gradient and the volume of traffic that competes with the bus for breaks in the frontage road traffic. This backup occasionally causes two westbound buses to stack at the intersection simultaneously and makes it difficult for buses to finish their circuits on schedule. The volume of shuttle van traffic on East Lionshead Circle is greater than it needs to be. ln order for westbound shufrles to reach their gueuing area in front of the Subway sandwich shop at the western end of the parking structure, they must drive the entire length of the road, turn around across from Dobson ice arena, and drive back to the queuing area. This movement requires the shuftles to conflict with the west pedestrian crossrng twice each trip. The most significant issue with the transit system along East Lionshead Circle is the drop-off area located at the westem end of the public parking structure. This drop-off area, home to buses, shuttle vans, delivery trucks, and personal vehicles, is poorly organized. As the main pedestrian poftal into Lionshead, it is one of the least functional and most congesfed elements in the study area. The primary problem with the drop-off area is the lack of any clear and safe pedestrian crosslng from the parking structure into the Lionshead pedestrian mall. Pedestians often walk through the bus lanes and across the small planter islands. Delivery vans obscure sight lines when pedestrians step into the traffic lane of East Lionshead Circle. c. Loading and Delivery Delivery vehicles need to access all of the residential and retail properties on East Lionshead Circle, but the vast majority travel only to one of two locailons. The first is the alley behind Vail 21, Lionshead Pride, and the Lifthouse Lodge. Seruice vehicles here conflict with a designated fire lane and significantly downgrade the pedestrian and vehicular anival experience to these buildings. The other concentration of service vehicles occurs at the East Lionshead bus drop-off. Vehicles parking here cause major conflicts at the pedestrian crossrng from the parking stucture and detract from the visual image of the primary pedestrian entry into Lionshead. Because these two areas together cannot adequately accommodate peak delivery volumes, seruice vehicles will occasionally stage outside the areas, further exacerbating traffic congestion. t2 d. Pedestrian Traffic The pedestrian systerns along East Lionshead Circle are marginal in quality and, in some cases (such as the connection between the public parking structure and the Lionshead mall), hardly functional at all. The section of the street from the eastern drop-off area to Dobson arena has a sidewalk but lacks pedestrian crossi'hgs to the residential properties. lt also lacks a dedicated pedestrian connection to the wallway east of Dobson that continues into Vail Village. The lack of a sidewalk on the south side of the street forces pedestrians to cross Easf Lronshead Circle twice or, more commonly, to walk in the street. e. Skier Drop-Off Duing the ski season the droryff area at the westem end of the parking structure is often used by private mofozsfs as a skier drop-off area although there are no designated skier drop-off locations. Automobiles pose a major conflict with delivery vehicles and further compromise the safety of . pedesfn'ans crosstng from the parking structure. Although it is convenient, skier drop-off at this location is dangerous and should be eliminated or redesigned. 3.9 Parkinq The ground rules of the Lionshead master plan state that future redevelopment will not cause a nef /oss of parking. An assessrnenf of existing parking conditions ls discussed in this section. For additional parking information on a town-wide basis, p/ease refer to the Town of Vail carrying capacity analysis and the Master Transportation Study. Existing public and private parking facilities in Lionshead are shown on Map l. 3.9.1 Parking Generation Pa*ing demand and generation in a mixed-use resort environment is difficult to quantify. lt is somewhat easier to analyze when broken out into its three components: parking generated by the lodging bed base, parking generated by retail/ commercial activity, and parking generated by the ski mountain and other destination activities and events. However, the ski mountain, the retail shops, and the lodging facilities do not represent discrete and separate populations, so the calculation of public parking demand is complicated by the high degree of overlapping between these different parking generators. To understand the relationship between future improvements in Lionshead and the public parking demand they will generate, one must first understand how vrslfors will arrive and what they will be doing during their stay in Vail. Only then can the incremental increase in public parking demand be estimated. 3.9.1.1 Parking Demand Generated by Lodging All private residential and lodging properties in Lionshead provide their own parking, either in surface or structured facilities. None, whether existing or planned, is expected to increase the demand 13 for public parking facilities. To the contrary, Iodgings within easy access of the ski mountain and the resoft core may actually reduce the demand for public parking facilities. 3.9.1 .2 Parking Demand Generated by Retail/ Commercial Space The retail base in Lionshead, with a few exceptions, utilizes the Town of Vail public parking facilities. Through the Town's pa*ing pay-in-lieu sysfem, refall bustnesses pay a one-time assessment on a sguare footage basis for the parking demand they generate. The pay-in-lieu formula does not fully adjust for the probability that the parking for many retail customers is already accommodated in their lodgings. 3.9.1.3 Day Skier and Special Event Parking During fhe skl season, day skiers are the largest users of the Lionshead public parking structure. While it is generally assurned that skiing, not retail, is the primary destination for the maiority of wintertime users of the parking structure, no survey data confirms tf,ts. 3.9.2 Existing Public Parking The Lionshead public parking structure has a capacity of approximately 1,200 cars. ln addition, a charter bus parking area is located at the eastern end of the Lionshead parking structure (see figure 3-14). 3.9.3 Existing Parking Shorffall According to the Town of Vail Master Transportation Study, the Lionshead parking structure is filled to capacity approximately 20 to 30 times during the winter, or roughly 20 percent of the ski season. During these times of capacity usage (Christmas, President's Day, Martin Luther Kng holiday), overflow parking occurs on the north side of the South Frontage Road. CHAPTER 4r MASTER PLAN RECOMMENDATIONS - OVERALL STUDY AREA (in part) This section of the master plan addresses lssues that affect Lionshead as a whole. Ihese lssues - and recommendations fo address them - should be considered in all planning and policy declsions as Lionshead redevelops. 4.1 Underlvinq Phvsical Framework of Lionshead The Lionshead resort area (that portion of the sfudy area north of Gore Creek) is a mixed-use urban environment with several discernible land-use sub-areas, or "hubs" (see Map N). Although the hubs overlap somewhat, there ls no consistent and comprehensive pedestrian connection between them. The primary goal of the master plan is to create a visually interesting and functionally efficient pedestrian environment that connects the hubs to create a cohesive and memorable resort environment. t4 4.1 .1 Lionshead Master Plan Concept Two primary pedestrian streefs form the backbone of Lionshead's physical plan: an easf-wesf corridor connecting Dobson lce Arena with the west end of Lionshead and a nofth-south corridor connecting the proposed nofth day lot transportailon center with the ski yard. The circulation sysfern and new retail and lodging components will follow the underlying pattem set by these corridors (see Map T) and the entry portals associafed with them. 4.1.2 East Lionshead - Civic Hub The civic hub of Lionshead is comprised of Dobson lce Arena, the Vail public library, the Lionshead public parking structure, and the proposed Vail Civic Center site on the east end of the parking structure. Although this area also contains severa/ lodging properties and may support offrce or retail development in the future, all planning and design dectsions here should be respectful of and compatible with these civic components. 4.2 Connection to Vail Villaqe The lack of connection between Lionshead and Vail Village was identified early in the master planning process. Although both West Meadow Drive and East Lionshead Circle connect the village to Lionshead, the pedestrian sysferns along this corridor are poor and the streefscape has no consisfenf visual character. The eastem entry to the Lionshead study area is at Middle Creek (at the Vail public library and Dobson lce Arena), but the true entrance to the Lionshead retail core is at the westem end of the Lionshead parking structure. Pedestrian connections should be sensdive to the residenfial uses on West Meadow Drive and East Lionshead Circle. It is also important that they be continuous from the intersection of Vail Road and East Meadow Drive in Vail to the west end of the parking structure in Lionshead. The Town of Vail Sfreefscape Master Plan recommendations for West Meadow Drive should be implemented in a way that ls consisfenf in design and character with the entire Vail Village/ Lionshead connection. 4.3 Connections to the Natural Environment One of the outstanding characteristics of Vail Village is its spectacular visual connection to Vail Mountain, particularly the protected view coridors up Bridge Street from the village pa*ing structure and toward the Gore Range from East Meadow Drive. Over the years the village has also strengthened its physical connections to the natural environment by improving creekside parks and trails and by integrating landscape into the built environment at every opportunity. l5 Lionshead has no similarly strong connection to the natural environment even though it is situated even closer to the base of the mountain. To remedy this critical deflciency, the following recommendations are made: 4.3.1 Visual Connections As development and redevelopment occur in Lionshead, it will be vital to protect visual connections to the ski mountain. Ihese visual relationshps strengthen the identity of Lionshead as an alpine resoft and provide a visual reference that helps Lionshead vl'sitors to find their way through the core. Visual connections to the natural environment should be established utilizing the following techniques: 4.3.1.1 View Conidors Creating and establishing view corridors is an effective way to link the urban core of Lionshead visually to the natural environment of Gore Creek and the mountain. The master plan is recommending the creation of several dedicated public view conidors. ln addition, all private development and redevelopment should endeavor to create visual connections from and through their propefties. View corridors do not have to be expansive to be effective. ln many cases, a slender but well targeted view conidor can be just as effective as a broad view. Nor do visual connections have to be continuous; they can reoccur, providing intermiftent views from different angles. 4.3.1.2 North-South Orientation of Buildings The Bredominant easf-west orientation of buildings in Lionshead acts as a visual and physical banier, interrupting the connection to the natural environment. lt should be a prioity in future development and redevelopment to orient vertical building rnasses along a north-south axis whenever possible. This will help to accomplish the following objectives: a. Sun Access During the winter months, the sun is low in the southern sky, providing the greatest solar exposure to the south faces of buildings and to sfreefs and spaces open to the south. A north-south oientation of building /nasses will increase the amount of sun reaching the Lionshead pedestrian core and the buildings to the north. b. Views from New Buildings ln double loaded buildings oriented on an east-west axis, units on the south side of the building get great views of the mountain, but units on the north side do not. Orienting the building rnass on a north-south line creates angled southern l6 views for both sldes of fhe building, and units on both sides will get direct sun sometime duing the day. c. Views from Existing Buildings Public input throughout the master planning process indicated that existing property owners in Lionshead are concemed that new development will block their private views to the mountain. By orienting new buildings on a north-south axis, the potential visual impact on exis1ng buildings is reduced. d. CreationofSfreefs A strong view corridor in the Vail Village is Bridge Street. The orientation of the street toward the mountain provides a constant sense of direction and draws people to the destination at the top of the street. Likewise, the proposed north-south orientation of buildings in Lionshead will help to create streets oriented to the views, something that is almost completely lacking today. 4.4 Public View Conidors 4.4.2 Public View Corridors Where Redevelopment of the Viewpoint or the Foreground is Likely It is proposed that the following three views be established as critical design parameters, but not as benchmarked and surueyed conidors. The extent to which an applicant for redevelopment creates or maintains these views will be a consideration for approval or disapproval by the reviewing board. Prior to approval of a redevelopment application by the Town Council the new view conidor should be surueyed and formally adopted in accordance with existing Town code. 4.4.2.1 View Conidor Three This view is from the east end of the Lionshead parking structure looking soufh across the Lodge at Lionshead buildings toward the ski mountain (see figure 4-3). This site has been identified for future development as a civic facility; when that happens, thrs view may become more importanL 4.6 Vehicular and Pedestrian Circulation 4.6.2 South Frontage Road 4.6.2.3 Provisions for Bicycles and Pedestrians A pedestian/ bicycle path should be created on the south side of the frontage road running the entire length of the Lionshead study area. Providing an unbroken pedestrian/ bicycle path to connect the main Vail roundabout to Cascade Village, this pathway will conform to the current Town of Vail standards regarding width and material. t7 4.6.2.4 Visual lmprovements /f rs essenf'al that improvements for better traffic flow be accompanied with aesthetic improvements in order to break up the perceived width of the improved roadway and to give a stronger image to this nofth edge of Lionshead (see figure 6-5). lmprovements could include landscaped medians and a consistent landscape treatment between the South Frontage Road and the eastbound lane of l-70. Fragile understory plantings should be avoided in favor of sfreef trees and hardy ground covers that can suruive winter snowplowing activities. This corridor should also include new directional signage, described in section 4.10.1.1 4.6.3 Modifications to East Lionshead Circle 4. 6. 3. 4 Visual I m prove ments As an important link in the transit connection between Vail Road and the east Lionshead pedestrian portal, East Lionshead Circle plays an important role in setting the visual tone and character for people arriving from Vail village. Toward that end, any architectural additions to the south face of the parking structure should comply fully with the architectural design guidelines, and the pedestrian walkway should create a consisfenf visual character connecting Dobson Arena with the east Lionshead pedestrian poftal. ln addition, it is recommended that the Town of Vail coordinate with the adiacent residential properties to provide a visually consistent vegetative screen on the south side of East Lionshead Circle. 4. 6. 3. 5 Pede stri an S idewal ks A new, more intensively developed pedestrian walkway is recommended along the south face of the parking structure to connect the main Lionshead pedestrian portal with the Dobson/ Civic center pedestrian plaza. This walkway will provide access to the potential new retail face of the parking structure and permit unimpeded pedestrian flow between the two ends of the parking structure (see figure 6-6). Given the long and linear nature of this fagade, a covered arcade across the wallouay, as suggesfed during the master plan public input process, may help to break it up. lf covered, the walkway should be wide enough to accommodate the flow of pedestrian traffic along the retail face and designed as an integral element of the building. 18 4.8 Parkinq Pa*ing is a critical component in a mixed-use resort environment such as Lionshead, and any efforts to enhance this component should adhere to the following goals and guidelines: a. Parking must be sufficient to meet demand. Correc1y assessing parking demand in an environment such as Lionshead is difficult but extremely important. Overestimating parking demand can be as damaging as underestimating demand due to the extreme expense of parking space (especially if structured) in a real estate environment such as the Vail Valley. Likewise, parking is a large consumer of ground and should be designed to occupy as little real estate as posslb/e. ln tight margin developments such as mid-range hotels and local{employee housing, the expense of parking can be the deciding factor as to the economic viability of the project. Due to these aftributes of parking, it is impoftant that true demand, or desired demand, be distinguished from actual usage. For example, the "free after three" program cunently in place for the Town of Vail parking structures has undoubtedly increased the usage of these sfrucfures during the evening hours (the Lionshead structure filled in the evening for the first time in 1998). However, there has not been a conesponding increase rn sa/es tax revenue, which was the original intent of 'Tree after three". (Note- concrefe sfudies regarding the utilization of the "free after three" program have not been conducted and it is strongly recommended that this occur if the program is to continue). lt is hypothesized that a significant portion of people utilizing the free parking program are in fact employees or people that would have used transit or other means of access if the parking were not as readily available. ln other words, parking usage often will rise to fill the available space, but the profile of the user may not be who the parking was intended for. To be concise, the parking supply in Lionshead and the Town of Vail needs to not only meet the demand, it needs to meet the desired demand and should be structured or programmed in such as way to do so. Pa*ing is important, but too expensive and land consuming to be provided without solid reasoning. b. Parking should relate to pedestrian circulation and desired points of access to the pedestrian core. A primary goal of redevelopment in Lionshead is to increase the quality of the .pedestrian connections into the retail/ pedestrian core and through it to the skl yard. Any new public parking must have a strong and convenient relationship to this primary destination. However, parking should not use prime developmenf slfes and does not have to be immediately adjacent. t9 c. Parking is only one part of an overall access strategy. Public parking is very important in bringing guests to Lionshead, but structured parking is expensive. The cost of structured pa*ing today ranges from 20,000 to 30,000 dollars per space, so other means of access should be carefully considered first. Posslb/e altematives include an enhanced transit system, more convenient drop-off facilities, a reduction in required parking ratios for ceftain uses (such as employee and locals housing), off-site and remote parking, and parking disincentives that discourage driving. d. Parking should be visually inconspicuous. Parking should be structured below ground whenever possib/e. Surface pa*ing areas should be heavily screened with landscaping, berms, and walls. Expanses of asphalt should be intemtpted with is/ands of landscaping or replaced with pedestrian qualrty paving materials. Surface parking areas should be avoided in or near the retail pedestrian core area. Although structured parking may be more desirable visually, it must be prcperly designed so as nof to detract from the guest's anival experience. e. Parking requirements should not constitute an unnecessary disincentive to redevelopment. A thorough review of the current parking pay-in-lieu code and pa*ing ratio requirements is recommended. Given the above dr'scusslons it is important that parking requirements accurately meet the true parking demand of new development and redevelopment. For example, a stated goal of the masterplan is to encourage, facilitate, and provide incentives for the expansion of ground level retail in Lionshead. While this expanded retail will likely represent some level of incremental increase to public parking demand in Lionshead, this demand needs to be accurately understood so the parking pay-inJieu fee does not make the retail expansion economically unfeasible. The following recommendations for parking deal with existing parking that may be displaced by development, private residentiaU lodging parking, public parking supply and demand, and pa*ing for locald employee housing. 4.8.1 Potential Displacement of Existing Parking The ground rules for the Lionshead master plan mandate no net /oss of parking as a result of redevelopment. Properties potentially affected by this policy include: 4.8.1.3 Charter Bus Parking Lot The charter bus parking area on the east end ofthe Lionshead parking structure is the proposed location for a future Vail civic/community center. The property is extremely valuable to 20 the community, and its current utilization as a parking lot is not ifs hlghesf and best use. Alternate locations for charter bus parking include the Ford Park parking lot and a down-valley sife. A drop-off point for fhe buses will still be necessary and is recommended as a component of the proposed tansit center on the north day lot. 4.8.3.3 Potential New Parking Sites To respond to the projected parking demand increase dlscussed in the traffic study, it is strongly recommended that all town-wide parking opportunities be examined or re- examined prior to any final planning or parking construction. Specific public parking opportunities in Lionshead include: a. Lionshead Parking Structure The existing Lionshead parking structure is a logical location for expanded public parking because it is already owned by the Town of Vail. Also, the structure is conveniently located between the proposed civic center on the east and the main portal to the Lionshead pedestrian mall on the wesl No other location offers visitors such ease of access. A self-ventilating split deck structure, the garage has six half decks, each holding approximately 200 vehicles (1200 spaces in total). The addition of one complete level would increase the structure by 400 spaces, two complete new levels by 800 spaces. Snow removal rs an rssue in the addition of new decks. The top deck of the structure is cleared manually with front-end loaders. Additional decks will make it impossible to continue this method, as the internal dimensions of the structure will not accommodate ftont-end loaders. In addition, the construction of a new delivery staging area on the west end of the structure will remove the snow storage area presently used. Alternatives include heating the upper deck, providing for an altemate snow removal access road to the upper deck, and construction of a roof over the entire structure. Public input during the masterplan process has indicated the importance of the eastward view, across the top of the parking structure, toward the Vail Village as rnotorlsfs travel east along the South Frontage Road and l-70. Future expansion plans of the Lionshead parking structure should consider the potential impacts expansion could have on this view plane. AIso an issue ls the necessary structural reinforcement of the existing facility to support the weight of additional decks. 2I 4.9 Emplovee Housinq Recent community surueys and grass-roots planning efforts such as Vail Tomonow have identified the lack of locals housing as the most crttical issue facing the Vail community. Early in the Lionshead master planning process, west Lionshead was identified as an opportunity area to implement some of the community's housing goals, particularly relating to employee housing. These oppoftunities and associated issues are outlined below. 4.9.1 No Net Loss of Employee Housing Ground rule number five of the master plan states that there shall be no net loss of employee housing in Lionshead as redevelopment occurs. 4.9.2 Visual /ssues The financial realities of affordable housing often require cost reducing measures, generally involving the quality of detailing, planning, and architectural design. Given the strong desire to make these housing prcjects feasible, it is recommended that some latitude be granted to affordable housing developers. However, if ls a/so important that financial realities not be used as an excuse to produce unsightly, poorly designed, substandard products. Employee housing does not need to match the architectural sophistication of a five star resorf developmenl but it does need to be good quality construction and design. Rivers Edge in Avon is a good example of an attractive yet affordable employee housing project. 4.9.3 Policy Based Housing Opportunities The first means of implementing housing goals in Llonshead is through policy based requirements such as the employee generation ordinance currently being pursued by the Vail Town Council. As required by a future ordinance, all development and redevelopment projects, as a prerequisite to project approval, should provide housing for employees generated and to the extent possib/e this housing should be located in the Lionshead area. 4.9.4 Potential Housing Sites Following are specific sifes thaf have been identified as suitable for locals and employee housing (see Map W). 4.9.4.1 South Face of the Lionshead Parking Structure The south face of the Lionshead parking structure was identified by the Lionshead master planning team, the public input 'wish list'process, and the Vail Tomorrow process as a potential location for housing. Depending on building height, this location could suppott lwo to three levels of housing located above a ground floor level of retail and commercial space. 22 Several planmng rssues are associated with this sde. Firsl because the structure will front the East Lionshead Circle pedestrian corridor, the architectural quality and relationship to the street and pedestrian environment will be very important. Sfricf sfandards of unit upkeep will have to be enforced. Second, any housing units at this location will be required to park in the Lionshead parking structure, but unit size and location should allow the parking ratio to be lower than that of a typical one or two bedroom unit. Third, it is recommended that the height of this potential development be limited so that mountain views from the top deck of the parking structure are not blocked. Lastly, the structural l'ssues relafing to an additional parking deck should be coordinated with any south face development scenario. 4.9.4.2 Top Deck of the Lionshead Parking Structure The upper deck of the Lionshead parkinj structure has also been identified as a potential location for housing. Although the parking structure does offer a large area, several critical planning considerations must be taken into account. a. Parking /ssues The most important future use of the Lionshead pa*ing facility is expanded public parking. No housing scenarlos should be pursued before assuring that public parking needs have been met. ln addition, housing on the structure must provide its own parking; there should be no net /oss of existing or future public parking on the stntcture. b. Structural lssues Engineering sfudles conducted during the master planning process indicate that the parking strucfure can accommodate future expansion above the existing upper deck, but not without structural reinforcement. Any housing on top of the structure must take into account the structural loading of the new development and the accom pa nyi ng cost i mpl ication s. c. Visual /ssues Because housing on top of the structure will be highly visible, it will have to adhere to the Lionshead Architectural Design Guidelines (see chapter 8) and provide for ongoing maintenance. Also, the view of the mountains across fhe top of the parking structure is an impoftant part of the arrival experience for visifors and contributes significantly to the Lionshead image and character. Any housing on the parking structure should endeavor not to block this view completely. 23 4.10 Gatewavs. Landmarks, and Portals The lack of spatial hierarchy or organizational clarity is a fundamental problem in the Lionshead pedestrian and vehicular network today. This section discusses the need to create a series of gateways, portals, landmarks and useful public spaces that will increase and enhance the character and identity of the pedestrian environment. 4.10.2 Landmarks A landmark is a significant architectural element that all the vrbrtors to Lionshead can identify and remember. Landmarks signify impoftant points of entry, turning points and critical intersections in the pedestrian network, as well as desftnafibns and visual reference points. The single landmark in Lionshead today is the Gondola clock tower, which will be replaced with the Vail Associates core slte redevelopment. Appropriate locations for new landmarks in Lionshead are the east pedestrian portal, the central retail mall adjacent to the main pedestrian plaza, and the west pedestrian poftal adjacent to the intersection of West Lionshead Circle and Lionshead Place. ln addition, the potential civic center complex at the east end of the parking strucfure should function as a significant architectural landmark for the east end of Lionshead. 4.11 Public Art Through the Art in Public Places board, the Town of Vail has long recognized the importance of public aft in pedestrian environments. Future development and redevelopment proiects in Lionshead, especially projects impacting the retail mall and primary pedestrian environments, should seek fo incorporate public art according to the Town of Vail Art in Public Places Master Plan (not adopted as of the writing of this document). Pedestrian circulation systems, portals and gateways, landmarks, pedestrian plazas and architecture all present opportunities to incorporate public art. GHAPTER 5: DETAILED PLAN RECOMMENDATIONS (in part) See Aftachment G. CHAPTER 6: SITE DEVELOPMENT GUIDELINES See Attachment D. CHAPTER 7: DESIGN STANDARDS See Attachment E. 24 CHAPTER 8: ARGHITEGTURAL DESIGN GUIDELINES See Attachment F. CHAPTER 9: IMPLEM ENTATION The intent of this chapter is to provide guidance to the Town of Vail as it seeks to implement the recommendations of this master plan. The recommendations regarding priorities, phasing, and timing are intended to be flexible, not binding, so fhaf the community can adapt the plan to changing conditions and priorities. The project priorities listed below are divided into public and private improvements, although many proiects will be implemented through joint public and private financing efforts. 9. 1 P roje ct P rio ritizatio n 9.1 .1 Public lmprovements The following list of major public improvements ouflined in previous chapters suggesfs priorities based on the relative importance of projects and the intenelationships among them. (The plan acknowledges, however, that other variables also influence future implementation decisions, including construction cosfs and funding availability. For example, the construction of a Gore Creek recreation path bypass ts nof as critical to the implementation of the master plan as the north day lot transportation center, but it might be built sooner because of its lower cost and access to RETT funds.) 9.1.1.6 Development on the South Face of the Parking Structure and East Lionshead Circle Streefscape This project includes two important elements: the creation of a retail/commercial and housing component and the enhancement of the East Lionshead Circle pedestrian corridor. Although these prcjects can stand alone, or could' occur prior to adjacent projects, they are closely related to the East Lionshead pedestrian portal, the Vail Civic Center, the addition of parking decks to the existing parking structure, and the sfreefscape connection along West Meadow Drive to Vail Village. The Town of Vail's efforts to promote housing for locals causes these projects to take on a higher priority. 9.1.1.7 Soufh Frontage Road Realignment and lmprovements The improvement of South Frontage Road, including widening and acceleration/deceleration lanes, will become more critical as exlstlng properties redevelop and add density. The timing of roadway improvements depends not only on the pace of redevelopment but also on the ability to finance the improvements. Decisions about realigning the road are contingent on the development plans for the west 25 vt. day lot and the Vail Associafes service yard. lt is likely that the improvements will happen in significanf phases. lmposition of impact fees on projects that add densi$ or traffic volume to Lionshead is one means to secure long- tenn funding. /f ls impoftant to note, however, certain improvements are needed now (acceleration/deceleration lanes, signage), making it more difficult to charge those expenses to future projects. 9.1.1.8 Parking Current needs may justify expansion of 500 parking spaces town wide today, but further study of future parking demand may be needed to verrfy this. Additional decks on the existing structure or a new public structure in west Lionshead may be necessary when the Vail Civic Center is constructed or development occurs on the west day lot and the Vail Assocrafes seruice yard. ln any case, the development of the wesf day lot will necessifafe replacement of this existing private parking with either structured parking or an adjacent surface lot. lf future parking sfudies demonstrate a need for significant public parking in the west Lionshead area, a ioint venture between Val Associafes, the Town of Vail, and other potential development interests shou/d be considered. 9.1 .1.9 Vail Civic Center Additional parking must be built (in the existing Lionshead parking structure or nearby) and the charter bus parking lot must be relocated before the Vail Civic Center can be built. ln addition, this proiect will be integrally tied to development on the south face of the Lionshead parking structure and the streetscape enhancements along East, Lionshead Circle. This will be a huge project and is likely to occur only after a longer period of planning and fund raising; other, more critical elements of the master plan should not be made contingent on its implementation. APPENDIX: MAPS See Attachment G. STAFF RECOMMENDATION As this is a worksession for the purpose of allowing the applicant to present an introduction to the Conference Center project, the Staff is not making a formal recommendation at this time. Staff does recommend, however, that the Commission listen to a presentation of the project proposal and provide any initial direction the Commissioners may have at this time; and then table these items for further discussion at the June 27,2005, Planning and Environmental Commission public hearing. 26 On June 27,2005, the Planning and Environmental Commission will be asked to conduct a worksesion to review the Lionshead Redevelopment Master Plan and. to begin evaluating the Conference Center project's adherence to the specific policies, objectives, and recommendations of the master plan. VII. ATTACHMENTS A. Vicinity MapB. Town Council Memorandum dated June 7, 2005 C. Chapter 5: Detailed Plan Recommendations (LRMP)D. Chapter 6: Site Design Guidelines (LRMP) E. Chapter 7: Development Standards (LRMP)F. Chapter 8: Architectural Design Guidelines (LRMP) G. Appendix Maps (LRMP) H. Applicant's Draft Project Master Plan 27 Attachment A TO: FROM: DATE: SUBJECT: Attachment B MEMORANDUM VailTown Council Conference Center Advisory Committee & Town Staff June 7. 2005 Conference Center Update and Decision on Next Steps Staff: Russell Forrest 1.PURPOSE The Conference CenterAdvisory Committee (Committee) would like to request the foffowing based on the direction received from the Town Council on May 17, 2O05: . To authorize the Town Manager to execute an agreement with Mortenson for predevelopment service as shown in attachment A.. Review input from the Committee on ideas to reduce construction costs for the facility.. Approve of additional expenditures to execute the direction provided by the Town Council on May 17th to move forward with the current design of the facility. BACKGROUND On April 20,zX(,4,the Vail Town Council authorized a series of next steps which included interviewing owner's representative firms for the Conference Center. On April 29, 2004, the Committee met to interview five owner's representative firms. On May 18,2004, the Vail Town Council authorized the Town Manager to execute a contract with Architectural Resource Consultants, lnc. to be the Town's owner's representative and funding for the first phase of this contract or $8,510. The Vail Town Council also authorized the Committee to negotiate with both Piper Jaffray and Kirtpatrick Pettis to be the Town's investment banker on this project. On June 1,2004, the Vail Town Council voted to approve the following requests from the Committee: Authorization to engage Piper Jaffray as the Town's investment banker for the Conference Center: Authorization to issue a request for qualifications (RFQ) for design team assistance on the Conference Center: Request to move fonvard with a negotiated guaranteed maximum price (GMP) process for engaging a design team and a general contractor (as opposed to a design build process). This essentially means that both the architect and general contractor will work for the Town of Vail; 2. . Request for the Vail Town Council to approve the next phase of an owner's representative contract. The preconstruction phase of the contract would cost up to $155,774. However, the Committee is only requesting $93,212 (includes fees and reimbursables) to fund this function until a decision is made by the Vail Town Council to issue bonds which is anticipated in the November/December 2004 time frame. On June 15,2004, the Vail Town Council reviewed and approved the following next steps: . Approval of the proposed process for engaging the public in the design team selection process;r Selection criteria for request for proposals; . Consideration of proposed process givens;. Review of updated project budget and interrelated parking costs; ando Consideration and review of the major points of the proposed scope of service request for proposals for design services (to be given to the top 3-4 teams selected in the qualification competition). On July 6,2004, the Vail Town Council reviewed and approved the following next steps: . Review the recommendation from the Committee on short-listing the design team candidates and to issue the Request for Proposals (RFP) to the six recommended design teams;. Review and approve suggested changes to the design team selection process from the Committee; andr Request permission to issue an RFP for a surveyor to survey the Lionshead parking structure site and surrounding area. On July 20,2004, the Vail Town Council unanimously approved the following: . A contract for design services with Fentress Bradburn; andr Approval of next steps for master planning the Lionshead parking structure/Conference Center site. On September 21 ,2004, the Vail Town Council, the Committee, Design Review Board (DRB) and Planning and Environmental Commission (PEC) reviewed five alternative site plans. In addition, the public reviewed the same alternatives on September 22,2004. The near unanimous opinion from the various groups that reviewed the site plans was that alternative three is the preferred choice. On October 15, 2004, the Vail Town Council met and reviewed an update on architectural images for the Conference Cenler and authorized the Committee to move forward with public discussions regarding the alternative styles. The Committee met on October 21 ,2004, and reviewed the qualifications submitted by six general contractors. After reviewing the qualifications, the Commiftee recommended to the Vail Town Council that three general contractors receive requests for proposals (RFP). Those general contractors include: . Hansel Phelps Construction. Hunt Construction Group/Hyder Construction. M.A Mortenson Company On November 2,2004, the Vail Town Council approved a motion to forward the above mentioned contractors RFPs. The design team of Fentress Bradburn developed three alternative architectural approaches. These images were not the elevations of the proposed Conference Center but rather provided alternative visions or inspirations that could be considered for the Conference Center. The three styles include: l. Bavarian/Traditional Vail style 2. Contemporary 3. Natural/Environmentally inspired style The Committee reviewed the public input associated with the three design alternatives on November 18, 2004. After reviewing the public input and the associated costs with each design option, the Committee forwarded a recommendation for the 'Architectural Vision lnspired by Nature." The Committee felt that this would create an outstanding architectural structure. The materials as envisioned by the design team would utilize "mountain" materials such as heavy stone and timbers. The roof element would be more iconic but is intended to reflect the form of the surrounding mountains. lt should also be noted that one member of the Committee, although not present on November 18, 2004, preferred theTraditional Vail Vernacularlook. OnDecemberT,2004,theVail TownCouncil voted 6-1 to direct the Conference Center design team to move forward with a "natural/environmentally inspired" design style. The Committee met on December 14, 2004, and voted to recommend that the Town of Vail purchase (using Conference Center funds) the water and sewer taps for the charter bus lot site. On December 21 ,2004 the Vail Town Council authorized that the Town purchase tap fees with the condition that the Eagle River Water and Sanitation District (District) provide a letter confirming that a tap fee could be used on the same site for a different use in the future and that the taps could be moved to another Town of Vail owned land. The District did provide a letter confirming this issue referencing the District's policies for doing tap transfers. The final cost ofthe tap fee was $297,896. On January 18, 2005, the Vail Town Council voted to continue to move in the direction of the "natural" design. The Vail Town Council did express concern about the roof of the facility. They furthermore asked that the design team develop alternative ideas for the roof of the facility. On March 15,2005, theVail Town Council received an update on the operational plan, design, and capital budget for the Conference Center. The Committee also forwarded a recommendation to the Vail Town Council to issue an RFP for operations, management, and marketing. ln. addition, the Committee recommended forwarding the design to the general contractors for pricing. The Vail Town Council approved both recommendations. 4. On March 17,2005 the Vail Town Council received a comprehensive update on the critical elements of the conference center. In addition, they considered three basis alternatives for the conference center. These alternatives included: Option A: Discontinue all work and expenditures on the project: lf the Vail Town Council is fundamentally uncomfortable with the risks associated with the project, then discontinuing all work on the project is a viable alternative. A future discussion would then be required regarding the disposition of existing funds collected for the Conference Center and how the dedicated lodging and sales tax for the Conference Center is addressed. Option B: lmplement the existing program and obtain additional revenue to pay for the budget overage. The current project design can not be built with the funds available today and budget parameters that limit debt service at$2.7 million per year. Option B involves bringing ballot language forward to the Council in August of 2005 and keeping the same basic design Option C: Reduce the Gost of the Facility and work within the existing revenue budget for the proiect. This option involves reducing the cost of the existing facility by cutting the size and scope of the facility. Staff recommends not cutting the facility to below 32,000 sq. feet meeting space based on the HVS study. After significant public input and Council deliberation, the Vail Town Council directed staff to: lmplement option B which involved moving fonrvard with the existing program while reducing costs to the reasonable extent possible. This step involves moving fonryard with the existing design and reviewing it with Town Boards. ln addition, Council directed staff to develop ballot language that would not only provide additional revenue for the construction of the facility but also an additional $1.5 million per year over and above annual debt service to pay for operational deficits. ACTION REQUESTED OF THE TOWN COUNCIL Based on the direction from the Vail Town Council on May 17th, staff and the Committee would request the following actions: Mortenson Contract Via a motion direct the Town Manager to execute the attached agreement with M. A. Mortenson Company (MAM) for preconstruction services. The Committee is requesting the Town Council authorize MAM to proceed with construction cost escalation research, strategies and management, design assist services, and cost trending monitoring for a monthly fee of $9,000/month. Staff would recommend that these services be funded for the period between May and November of 2005, and costs be capped at $54,000. Value Enqineerinq The Conference Center Advisory Committee and staff met with the project team and after consideration of life cycle cost impacts, quality of the building, and the mission of the project, recommend the following value engineering (numbers approximate): $1,400,000 250,000 512,000 220.O00 $2,382,000 Project Team recommendations to Committee & Staff (changes not affecting exterior\interior finishes, or operaling costs of the building) Waterfall feature removed Change ceiling in ballroom from wood to ACT Change concrete retaining walls to block walls Total Proiect Budqet Aporoval The 2005 Budget assumed bonds would be sold in April/May of 2005; after that decision, funds would be allocated to continue the design process. Based on direction from the Vail Town Council on May 17th to move forward with: o design,o begin the review process by the Town Boards,o get more certainty on construction cost escalation, the total potential expenditures in 2005 is projected to be approximately $1 .8 million. This would provide for design services, preconstruction services from Mortenson, and Owners Representative services through the end of the year. By November of 2005, the design would be nearing completion of construction drawings. The Town would be poised to issue a notice to proceed immediately after an election if the result was to move forward with the conference facility and thereby avoid further marketplace risk. Staff would request that an additional $1.8 million be authorized via a motion to be spent in 2005 for the conference center. These expenditures fall within the current soft costs for the project. This appropriation would be reflected in the August supplemental budget. ATTACHMENTS: A. Mortenson Agreement F lcdev\COUNCI L\ME MOS\0s\conference cente1060705.doc TO: FROM: DATE: SUBJECT: MEMORANDUM Planning and Environmental Commission Community Development Department July 11, 2005 A request for a correction to the Vail Land Use Plan to designate the Lionshead Redevelooment Master Plan Area and an amendment to the Lionshead Redevelopment Master Plan to amend, in part, Chapter 5, Vail Civic Center Detailed Plan Recommendations, and setting forth details in regard thereto; and, a request for a final review of a conditional use permit, pursuant to Section 12-9C-3, Conditional Uses, Vail Town Code, to allow for a public convention facilily and public parking facilities and structures, located at 395 East Lionshead Circle/Lot '1 , Block 2, Yail Lionshead Filing '1 , Lot 3 and 5, Block 1, Vail Lionshead Filing 2, and setting forth details in regard thereto. Applicant: Town of Vail, represented by Pylman & Associates, Inc.Planner: Bill Gibson il. SUMMARY The applicant, Town of Vail, represented by Pylman & Associates, Inc., has submitted applications to allow for the construction of a Conference Center located at the "Charter Bus Lot' site adjacent to the Lionshead Parking Structure. Today's discussion will be a work session to further discuss the proposal. The Commission is not being asked to take any formal actions at this time. BACKGROUND On June 13 and 20,2005, the Planning and Environmental Commission held a worksession to discuss the proposed Conference Center project. On July 6, 2005, the Design Review Board conceptually reviewed the proposed Conference Center project. DISCUSSION ITEMS A. Additional Applications/Submittal Requirements 1. Required Approvals The proposed Conference Center project will require the following approvals:. General election ballot initiative for additional fundingr Resolution of all private protective covenant issueso Approval from Vail lnternational (construction on their property) |il. r Conditional Use Permit (Conference Center)o Conditional Use Permit (parking structure modifications). Design Review (Conference Center, parking structure, East Lionshead Circle and South Frontage Road streetscape)r Variance (excessive driveway grades)r Lionshead Redevelopment Master Plan amendmentsr Minor Subdivision Amended Final Platr Colorado Department of Transportation Permits 2. Additional Applications Minor Subdivision: Currently the Lionshead Parking Structure and the proposed Conference Center are located on two lots and the East Lionshead Circle Right-of-Way. The applicant must update these property boundaries and vacate the existing, abandoned portions of the East Lionshead Circle Right-of-Way through the minor subdivision application process. Variance: The proposed driveway from the South Frontage Road to the Conference Center's eastern parking structure entrance and loading dock entrance are too steep to comply with Town of Vail's minimum engineering standards. The applicant must amend the proposed driveway to comply with these standards (Title 14, Development Standards Handbook, Vail Town Code) or receive Planning and Environmental Commission approval of a variance. 2. Required Additional Application Materials The following is a prelimindry list of materials, in addition to the above listed applications, not yet submitted by the applicant: a 3- dimensional model of the Conference Center and its surrounding, development standard calculations, architectural plans showing the Conference Center in its neighborhood context, statements of compliance with the Town of Vail Streetscape Master Plan and the Town of Vail Transportation Master Plan, and any other materials deemed necessary by the PEC, DRB, or staff. B. Zoninq Requlations 1. General Use Zone District The Lionshead Parking Structure and Charter Bus Lot are zoned General Use District. Within the General Use District the allowed development statistics are prescribed by the Planning and Environmental Commission as oart of a conditional use permit application. o Purpose The general use district is intended to provide sites for public and quasi-public uses which, because of their special characteristics, cannot be appropriately regulated by the development standards prescribed for other zoning districts, and for which development standards especially prescribed for each particular development proposal or project are necessary to achieve the purposes prescribed in section 12-1-2 of this title and to provide for the public welfare. The general use district is intended to ensure that public buildings and grounds and certain types of quasi-public uses permitted in the district are appropriately located and designed to meet the needs of residents and visitors to Vail, to harmonize with surrounding uses, and, in the case of buildings and other structures, to ensure adequate light, air, open spaces, and other amenities appropriate to the permitted types of uses. o Uses "Public theaters, meeting rooms and convention facilities" (i.e. the proposed Conference Center) and "public parking facilities and structures" (i.e. the Lionshead Parking Structure) are allowed within the General Use District subject to Planning and Environmental Commission approval of a condilional use permit. Lot area/site dimensions The Conference Center development site includes the existing Lionshead Parking Structure, Charter Bus Lot, and the East Lionshead Gircle Right-of-Way. The proposed development site boundaries and lot area can not be accurately determined until the applicant submits a minor subdivision application to replat this property. Setbacks The determination of setback standards can not accurately be determined until the applicant submits a minor subdivision application to replat this property. At this time the Conference Center building is approximately 10 feet from the South Frontage Road Right-of-Way on the north, abuts the Lionshead Parking Structure on the west, encroaches up to 30 feet into the East Lionshead Circle Right-of-Way on the east, and is 0 to 90 feet from the East Lionshead Circle Right-of- Way Right-of-Way on the south (however, proposed decks do encroach from the south side of the building into the East Lionshead Circle Right-of-Way). Building Height The applicant must submit a revised building height calculation plan; however, the Conference Center's primary ridge appears to be 70 feet in height above the current Charter Bus Lot grade. The proposed eave line on the south side of the building will be approximately 80 feet in height above East Lionshead Circle. Density Control There are no dwelling unit or gross residential floor area (GRFA) proposed with the Conference Cenler project. The applicant is curently proposing the following floor area program for this building:Use Square Footage Pre-function and lobby: 13,776 Ballroom: Meeting rooms: Meeting room support: Operations: Loading Dock: Administration: Food Service/Kitchen: 4,434 30,008 10,100 4,392 18,523 12,649 3,302 lnfrastructure/circulation: 23.367 Total: Site Goverage 123,205 The determination of site coverage standards can not accurately be determined until the applicant submits a minor subdivision application to replat this property. The applicant is estimating the proposed site coverage to be 59,677 sq.ft.. The applicant estimates this to be 61% of what they consider the Charter Bus Lot site. Landscaping and Site Development The determination of landscaping standards can not accurately be determined until the applicant submits a minor subdivision application to replat this property. The applicant is proposing to landscape the 10-12 foot wide median between the Conference Center and the South Frontage Road. The applicant is also proposing a landscaping bed at the northeast corner of the Conference Center with an approximately 10 foot strip of landscaping between the building and the east access drive. The applicant is also proposing a 10 to 40 foot wide strip of landscaping between the access drive and Vail International and Dobson lce Arena; however, much of this proposed landscaping is located within the existing East Lionshead Circle Right-of-Way and on Vail International's property. There are also small landscape planters proposed along the south side of the Conference Center building. The appficant is estimating the proposed landscaping to be 7,142 sq. ft.. The applicant estimates this to be 7% of what they consider the Charter Bus Lot site. The applicant is also proposing a hardscape areas at the north entrance to the facility and a hardscape patio area on the south side of the building along East Lionshead Circle. The applicant is estimating the proposed hardscaping to be 59,677 sq.ft.. The applicant estimates this to be 13% of what they consider the Charter Bus Lot site. Existing landscaping will be removed along the north side of the Lionshead Parking Structure to accommodate the new entrance and along the south side of the structure to accommodate the new shuttle bus turn-around. Parking and Loading Required: 334 spaces Proposed: 125 spaces Pursuant to Section 12-10-10, Vail Town Code, convention facilities are required to provide 1 parking space per 120 sq. ft. of seating area. The applicant is proposing approximately 30,000 sq. ft. of ballroom area and approximately 10,000 sq. ft. of meeting rooms. This approximately 40,000 sq. ft. of seating area requires 334 parking spaces. This does not take into consideration the 14,000 to 21 ,000 sq. ft. of pre-function, registration, corridor, vestibule areas which are commonly utilized by conference and event organizers. Including these areas would increase the parking requirement by 116 to 175 additional spaces. The applicant is proposing to construct a 325 space parking structure within the Conference Center building; however, 75 of these spaces replace the 75 space eliminated by the construction of the new Lionshead Parking Structure entrance. Construction of the other 125 spaces is being funded by Vail Resorts and may be used to off-set their parking requirements for their other Lionshead area construction projects. The applicant has hired HVS Convention, Sports, and Entertainment to prepare a parking analysis. The applicant is proposing that this analysis justifies the construction of 125 parking spaces for the conference center rather than the minimum of 334 required by the Town Code. A copy of the analysis was attached in the June 13, 2005, Planning and Environmental Commission memorandum. The HVS analysis examines the parking use demands for the Conference Center in relation to the public use of the Lionshead Parking Structure. The new conference center parking structure is designed to connect to the Lionshead Parking Structure. The analysis generally concludes that parking is adequately addressed on "design days" and "peak days" during the shoulder and summer season; however, parking deficits still exist on both "design days" and "peak days" during the winter season. The proposed South Frontage Road improvements include the construction of a widen shoulder on the north side of the road. lt is anticipated that winter season over-flow parking will continue to be accommodated along the South Frontage Road. The parking analysis recommends 10 of the 125 parking spaces be used for the estimated 20 full-time employees. The analysis recognizes that large events of 1,000 or more people may require 12 additional staff plus 70 to 80 part-time staff (at the July 6, 2005, Design Review Board meeting, the applicant noted that community events of up to 3,000 people could be accommodated). The parking analysis identifies the need for an appropriate facility management plan to address the transportation needs of both conference center employees and users; especially during large conference center events, during peak days, during the winter season, or when other large parking demands are placed on the Lionshead Parking Structure such as events at Dobson lce Arena. o Employee Housing The Town of Vail's requires development projects to provide housing for 15o/o of all new employees. The Town of Vail calculates the number of new employees based upon the 1991 Rosall Remmen Cares "Employee Generation Rates" analysis, unless more specific, project specific employment information is available. The applicant has not provided the Town of Vail Housing Division, or the Vail Local Housing Authority, with any specific employment projections. Therefore, the "Employee Generation Rates" analysis will be used to calculate the employee housing requirement for the Conference Center project. This analpis calculates employee generation for a conference center at a rate of 1 employee per 1,000 sq. ft. Based solely upon the ballroom and meeting room area of approximately 40,000 sq. ft., 40 new employees will be generated by the Conference Center project. This employee generation calculation does not include any pre-function, registration, corridor, or vestibule areas which are commonly utilized by conference and event organizers; nor does it include any kitchen or office spaces. Based upon 40 new employees, the Conference Center is required to provide housing for 6 employees. The applicant is not proposing to construct any employee housing. Instead, the applicant is proposing to provide the Town of Vail with the cash equivalent of 7 employee housing units; however, the Town has no adopted formally adopted "pay-in-lieu" program. 2. Conditional Uses The Planning and Environmental Commission will be reviewing the proposed conditional use permit applications for the Conference Center and Lionshead Parking Structure based upon the following criteria: 1. Relationship and impact of the use on development objectives of the town. 2. Effect of the use on light and air, distribution of population, lransportation facilities, utilities, schools, parks and recreation facilities, and other public facilities and public facilities needs. 3. Effect upon traffic, with particular reference to congestion, automotive and pedestrian safety and convenience, traffic flow and control, access, maneuverability, and removal of snow from the streets and parking areas. 4. Effect upon the character of the area in which the proposed use is to be located, including the scale and bulk of the proposed use in relation to surrounding uses. 5. Such other factors and criteria as the commission deems applicable to the proposed use. B. Lionshead Redevelopment Master Plan The Lionshead Parking Structure and the Charter Bus Lot are located within the boundaries of the Lionshead Redevelopment Master Plan, and the proposed Conference Center project must be reviewed for conformance with the master plan. There are numerous portions of the master plan that are applicable to this project and the Commission should review the master plan document and the Staff memorandums dated June 13 and June 27 , 2OO5, for additional information. 1. Purpose/Objectives: There are several fundamental design objectives of the Lionshead Redevelopment Master Plan that are applicable to the Conference Center project:. Pedestrian Environment:o create a generator for activity; create a cohesive, consistent, well defined pedestrian/retail environmento create a connection between Dobson lce Arena and the west edge of Lionshead. Vehicular Circulation: create efficient access to private and public destinations without negative impacts to pedestrian and residential areaso Transit: an effective and flexible public transit system is essential for the entire Lionshead area.. Service and Delivery: a consolidated, efficient network meeting current and futures needs that reduces interference with pedestrians, emergency services, and traffic.. Parking: to provide adequate public parking in Lionshead and the communitv as a whole 2.Existing Gonditions: The Lionshead Redevelopment Master Plan thoroughly inventories the existing conditions of the Lionshead area. An important item of note within this inventory includes the identified need for additional meeting/conference facilities within the Lionshead area. Also within this inventory, the master plan identifies the need to address bicycle/pedestrian traffic, vehicular turning movements and parking along the South Frontage Road; and the need to address pedestrian traffic, transit, loading/delivery, and skier drop-off along East Lionshead Circle. The Lionshead Redevelopment Master Plan also identifies the need to address the existing parking shortfall within the Town of Vail and highlights how no new development should create a net-loss of parking. Recommendations: The Lionshead Redevelopment Master Plan makes numerous general and specific recommendations that are relevant to the proposed Conference Center project. General Recommendations: The following is a very brief summary of the general recommendations applicable to the Conference Center project:. The proposed Conference Center, the Lionshead Parking Structure, Dobson lce Arena, and the Library should create an "East Lionshead Civic Hub".. A physical connection needs to be created between Lionshead and Vail Village, a part of which should include streetscape improvements.o Connections need to be made to the natural environment, which can be addressed in numerous ways including building orientation and the preservation of view corridors.. lmprovement should be made to the South Frontage Road to provide a bicycle/pedestrian path, improve circulation, and improve the visual quality of the street.r Loading and delivery facilities should be located within buildings and the impacts of traffic, noise, exhaust, etc. should be minimized.o An intensely developed pedestrian walkway should be developed along the south edge of the Lionshead Parking Structure.r Architecture and landscaping along East Lionshead Circle should create a consistent architecture to link Dobson lce Arena with the east portal of Lionshead.. Parking must be sufficient to meet the demand, parking should relate to pedestrian circulation and access points, new parking should be constructed below-grade, and no construction shall cause a net loss of parking.e The Lionshead Parking Structure is a potential location for new, additional public parking. 3. . Charter bus parking may be displaced by a new conference center. An alternate bus parking locations include Ford Park, new transit center, or down-valley.. The Lionshead Parking Structure is a potential location for new employee housing.. Development projects should seek to incorporate public art according to the Town of Vail Art in Public Places Master Plan. Detailed Plan Recommendations: The following is a very brief summary of the detailed plan recommendations for the Conference Center project:r A future civic center (i.e. the Conference Center) should accommodate a variety of uses, but the Town Council will decide the specific development program. . The Lionshead Parking Structure should be the primary means of access to the Conference Center.. The southeast corner of the site should be a drop-off area and arrival point for people walking.. The front entrance should be highly visible with ample plaza space.o The front doors should provide vertical building and pedestrian plaza.r An architeclural connection between the and Dobson lce Arena is needed.. A cohesive pedestrian plaza should link the new center, Dobson lce Arena, Library, and the Lionshead Parking Structure.. lf the East Lionshead Circle extension is closed. a new access for Vail International is required on the South Frontage Road.. Delivery points should include the southeast end of Dobson and/or a South Frontage Road access for the new civic center. No delivery points should create regular delivery trafflc on East Lionshead Circle.r The Conference Center should serve as East Lionshead Circle visual terminous.. A strong connection is needed between the Conference Center's pedestrian plaza and East Lionshead Circle.o A strong connection is needed between the Conference Center and Dobson lce Arena and may include common entrances, lobbies, ticketing, concessions, and a below-grade tunnel.o Additional parking must be built (in the existing Lionshead parking structure or nearby) and the charter bus parking lot must be relocated before the Conference Center can be built. Additional decks on the existing structure or a new public structure in wesl Lionshead may be necessary when the Conference Center is constructed.. The Conference Center is integrally tied to development on the south face of the Lionshead parking structure and East Lionshead Circle streelscape enhancements. access through the Conference Center 4. Architectural Design Guidelines: The Lionshead Redevelopment Master Plan includes specific qualitative and quantitative architectural design guidelines for new development and redevelopment projects within the Lionshead area. These guidelines address: : B:ii:il3 [:',ill* Massins r Exterior Walls. Exterior Doors and Windows : R:';;"n,"t, Guardrails, and Handrails : 5::i',:*'andchimnevsr Quantitative Criteria The Design Review Board will be reviewing the proposed Conference Center in context of these requirements. lt is Staffs belief that the proposed Conference Center will not fully comply with these guidelines and the applicant will need to pursue an application to allow for deviations from these standards. Such a request will require the review and recommendation of the Design Review Board followed by review and approval by the Planning and Environmental Commission. The quantitative standards of these architectural guidelines should be considered by the Planning and Environmental Commission during the review of the Conference Center conditional use permit application. The following quantitative criteria are directly applicable "' :"':'53 i:",,?1 lT; T:in"*'ili' | ! i ,", n,,,,' ste p ba ckr Ridge heights: 71 ' average maximum height and 82.5' absolute maximum height. Wall surfaces: 35' maximum vertical face and horizontal steps requiredo Horizontal Wall Spans: 30' maximum span at street levelo Roof Dimensional Guidelines: 30" min eave and rake overhangs, and lS" overhangs at secondary roofs. Roof Pitch: primary roof from 6:12 lo 12:12 and secondary roof from 4'.12to 12'.12 (or flat). IV. STAFF RECOMMENDATION As this is a worksession, the Commission is not being asked to take any formal action at this time. Staff recommends the Commission table these items for further discussion at the July 25,2005, Planning and Environmental Commission public hearing. IV. ATTACHMENTS Attachment A: Design Development Plans, April 2005 l0 EEH ;F" +:_'t- 4: EF'I E&t It c(uil o =a rooo C\ I II L CL *,g o E CLo o oo c ct) II ooo I C G' -o. o+,TI @ $$ € I E oJ ct .gv (u(L o3oJ u?oo (\ -II l- CL oo I otr(tr I o- t-oo -IL "lIri tr,r III W/''-!r'-tl '.!i -1 -t- CDE o c) o oJ o3o I ttt I 1l)ooC\ -IIL CL oo I oc (E I o- Loo -lt Q)r- -!i ,t c{ @ -l@(0 o I E o Eoot o)c oo .Yooo o) .EEoo q)c -YLo 0- 1()oo (\ I II L CL oo I otr G -o- l-oo III =;j ,r'O OCIO C -rLl __ B t \\\5'\.)* 4a7 O)@ @ 6 oJ Eo € (U co C'6 1()oosl I II l- CL oo I ag (E o- Loo lt . CYOU 39y11isg, I ./.1 1r)o c\I@ 6 oJ G .oc(u -c(J o) tro og .a-'= EE roooc\ -II L- CL oo I oc G o- l-oo -l! q) oq)og o(L E(tt ot 0)o,(E cI TL @Go-cEoz lt)oo C\ -II L CL +,co E CLo I o oo c ct) II ooo I oo II+,oo CLoLo o- o) o 0) CLoLoIL Eoo-cac .o oooE+,foa lt)oo (\ I IIL CL +fco E CLo I o oo c ct) II ooo I ao II+,oo CLoLo o- o oo CLat-o(L ! G 0) -cac .9 tt,o = =oa roooN I II l- CL +,tro E CLo I o oog CDt-ooo I oo II+,oo CLot-oo. o .F ooo-at-o(L ao3Etoz 1()oo C\ -II l- CL +.g o E CLo I o oog ct) II ooo I oo II+,oo CLoLo o- u?oo C\ -IIl- CL +,tro E CLo -o oo E ct) IIooo T Co TI*, G o I IJJ ? -*,Loz 1()oo (\ -l-L CL *fco E CLo I o oo tr ct) II ooo T co II*, TE o I IJJ +,o(E IIJ lt)oo (\ -IIL CL +,co E CLo -o oo c E' II ooo I tro II+,(E o -UJ -c+, =oa 1()oo C\ I II L CL +,tro E CLo I o oo C ctt II ooo I co l-+,(E o -IJJ +foo -- rooo (\ I II l- CL +,co E CLo o oo tr cttt-ooo T co II+f(E o -IJJ *,oo -- \1 TO: FROM: DATE: SUBJECT: MEMORANDUM Design Review Board Community Development Department October 20. 2005 A request for final review of architectural deviations, pursuant to Section 8.3.3.A, Review Criteria for Deviations to the Architectural Design Guidelines for New Development, Lionshead Redevelopment Master Plan, to allow for a public convention facility and public parking facilities . and structures, located at 395 East Lionshead Circle/ Lot 1, Block 2, Vail Lionshead Filing 1, Lot 3 and 5, Block 1, Vail Lionshead Filing 2, and setting forth details in regard thereto. Applicant Town of Vail, represented by Pylman & Associates, Inc. Planner: Bill Gibson il. SUMMARY The applicant, Town of Vail, represented by Pylman & Associates, Inc. and Fentress Bradburn Architects, Ltd., has submitted an application to allow for deviations from the Architectural Design Guidelines of the Lionshead Redevelopment Master Plan. Pursuant to Resolution 18, Series of 2004, the Town of Vail Design Review Board is responsible for the review of such deviations and for forwarding a recommendation to the Planning and Environmental Commission of approval, approval with modification/conditions, or denial of the proposed deviations. APPLICABILITY The proposed conference center will be located on the charter bus lot and is zoned General Use District. Although the proposed conference center is not located within the Lionshead Core retail area or zoned Lionshead Mixed Use I District; the project is located within the Lionhead Redevelopment Masler Plan boundaries and some form of a "civic center" is contemplated by the plan for this location. Therefore, the provisions of the Lionshead Redevelopment Master Plan's Architectural Design Guidelines are applicable to this proposed conference center. SUMMARY OF PROPOSED DEVIATIONS Ghapter 2, Introduction, Lionshead Redevelopment Master Plan (excerpts) 2.3 Policy Objectives The Town Council adopted six policy objectives on November 4, 1996 lo outline the important issues to be addressed in the master plan and to provide a policy framework for the master planning process. ilt. ,t 2.3.1 Renewal and Redevelopment Lionshead can and should be renewed and redeveloped to become a warmer, more vibrant environment for guests and residents. Lionshead needs an appealing and coherent identity, a sense of place, a personality, a purpose, and an improved aesthetic character. Vitality and Amenities We must seize the opportunity to enhance guest experience and community interaction through expanded and additional activities and amenities such as performing arts venues, conference facilities, ice rinks, streetscape, parks and other recreational improvements. Stronger Economic Base Through Increased Live Beds In order to enhance the vitality and viability of Vail, renewal and redevelopment in Lionshead must promote improved occupanry rates and the creation of additional bed base ("live beds" or lrvarm beds') through new lodging products. lmproved Access and Girculation The flow of pedestrian, vehicular, bicycle and mass transit traffic must be improved within and through Lionshead. lmproved Infrastructure The infrastructure of Lionshead (streets, walkways, transportation systems, parking, utilities, loading and delivery systems, snow removal and storage capacity) and its public and private services must be upgraded to support redevelopment and revitalization efforts and to meet the service expectations of our guests and residents. Greative Financing for Enhanced Private Profits and Public Revenues Financially creative and fiscally realistic strategies must be identified so that adequate capital may be raised from all possible sourc€s to fund desired private and public improvements. Urban Design Principles On November 4, 1996, the Town Council adopted the following set of urban design principles to guide the development of the master plan: 1. Connect Lionshead physically and visually to the mountain landscape. 2. Make people physically and emotionally comfortable in Lionshead. 3. Provide a sense of arrival to demarcate the Lionshead district. 4. Create landmarks and turning points to guide people through the area and make it memorable. 2.3.4 \ 5. Provide gates and portals to help define the sequence of public spaces and places. 6. Define appropriate land uses adjacent to outdoor spaces. Ghapter 8, Architectural Design Guidelines, Lionshead Redevelopment Master Plan (excerpts) 8.1 Vision Statement The Lionshead neighborhood in Vail presents the opportunity to establish . a dynamic and exciting community within one of the premier resorts in the world. Lionshead's mountain location, proximity to the ski slopes, and ample residential base evokes the vision of a truly special place, full of vitality and interest. This vision can be achieved through redevelopment of the community by addressing site and architectural issues, and through consistent and effective transitions from existing to new buildings. The pedestrian experience of the public spaces within Lionshead is the most critical issue for redevelopment. Many of the existing spaces are static and uninteresting, due to a prevailing grid organization and lack of animation and architectural coherency within the spaces. One of the most effective ways to intensify this experience is through careful design of the architecture which defines the public spaces. Visually dynamic variation at the pedestrian level can help avoid a monotonous streetscape, and judicious use of omament, detail, artwork, and color can reflect individuality and establish a variety of experience. The architecture of Lionshead is envisioned as a unified composition of buildings and public spaces based on the timeless design principles of form, scale, and order, made responsive to their setting and environment. It is not envisioned as a strict dictration of a specific "style' or theme." Many existing buildings within the community are built of monolithic concrete slabs and lack any sense of order or personality. The new image for Lionshead should move towards the future-using historical alpine references and Vail Village as antecedents. This design framework will allow individual property owners freedom of expression within the personalities of their buildings while establishing and maintaining an overall unifying character and image for the entire community. ln addition, it is paramount that the redevelopment effort address specific design considerations generated by the location, climate, and surrounding environment, such as addressing views, using indigenous building materials, and reflecting the alpine heritage. Designing in response to our regional heritage, adhering to a consistent architectural order, and enhancing the public experience will enable Lionshead to define its own identity-making it a distinct and special place not just within the context of Vail, but within kindred mountain communities around the world. I 8.2 Organization, Purpose and Scope The purpose of the Lionshead Architectural Design Guidelines (ADG) is to work in concert with the Lionshead Master Plan to enhance the existing experience within the community, improve the quality of life, focus direction for future growth, create visual harmony, and improve property values for businesses and homeowners. This document constitutes a design philosophy for the community, which when integrated with the Lionshead Master Plan, helps to establish Lionshead as a coherent, dyramic village with a true "sense of place." These Guidelines are intended to direct the growth of the community through distinct levels of perception, from views of the neighborhood from the mountain and the highway, to perceptions within its pedestrian streets, to the detail level of artistry and omamentation on the structures themselves. 8.3.3. A Review Criteria for Deviations to the Architectural Design Guidelines for New Development Similar to the implementation policies of the ADG prescribed for existing structures, the Town has determined that there may be instances where flexibility in requiring strict compliance with the Guidelines for new development maybe in the best interest of the community and the furtherance of the goals and objectives stated in the Lionshead Redevelopment Master Plan. That said, however, it is acknowledged that such instances are rare and extraordinary, and shall be considered on a case-by-case basis. To aid in determining when flexibility shall be afforded to new development from strict compliance with the Guidelines, review criteria have been established. The degree of design deviation flexibility afforded to a development project shall bear proportionately to the extent of the improvements proposed. For example, a development application that proposes the construction of a new structure which includes the demolition of an existing structure or adds significant volume or mass to a property, shall more fully comply with the prescribed Architectural Design Guidelines outlined in the master plan than an application which proposes a renovation or addition to an existing building. The following criteria shall be used by the Town of Vail Planning & Environmental Commission and Design Review Board to determine if deviations to the Guidelines should be granted: It shall be the burden of the applicant to demonstrate to the satisfaction of the Town of Vail Planning & Environmental Commission following a recommendalion from the Design Review Board that: . The request for design deMations are in compliance with the purposes of the zone district; and r The proposal which includes the design deviations is consistent with applicable elements of the Lionshead Redevelopment Master Plan; and The proposal which includes the design deviations does not have a significant neigative effect on the character of the neighborhood; and The proposal substantially complies with other applicable elements of the Vail comprehensive plan; and The design deviation meets or exceeds the intent of the specific design standards as prescribed in Section 8.4; and, . A public benefit is achieved as a result of the design deviation; and, . The design deviation furthers the goals, objectives and purposes as stated in Sections 2.3, 2.5 and 8.2 of the Lionshead Redevelopment Master Plan. 8.4.1.2 Building"Roles" Portals Portals act as the "front doors" to communities or urban spaces and therefore often present the first images to pedestrians. Buildings which are located on key sites need to act as inviting and "friendly" portals to or within Lionshead. Stand-alone structures can act as portals through appropriately-scaled, large openings and significant mass, while multiple structures can accomplish this through proper siting and relationship to one another. Human scale can be achieved with portals by introducing horizontal architectural components which relate to the surrounding context, such as retail frontage heights and other critical eave heights. This can also be achieved through careful design of detail which is considerate of the human form; that is, detail which relates to dimensions people are most comfortable with, such as railing heights, head heights, story heights, and similar proportions. Portals within Lionshead can be effective if they present enough mass to enclose the spaces they are defining, with enough open area to present the sense of entry needed for a community of its size and complexity. They may serve additional functions as well, such as living areas, bridges, or enclosed connectors, which can help to further animate the portals and provide additional income-generating soace. Edge Definers Whereas portals act as the Tront doors" to urban communities, edge- defining buildings act as the "exterior walls" for communities. Where the edges of Lionshead meet areas exterior to the community such as ' Vail Village, the Gore Creek Corridor, and the highway, buildings must present appropriately-scaled, well-defined edges to contain Lionshead or act as distinct transition zones from one neighborhood to the next. The form, massing, and height guidelines identified in Sections 8.4.2.2 and 8.4.2.3 will direct much of the design of these edges, but additional considerations such as building siting, scale, and architectural image should be taken into account as well. I Building siting should allow for openings to occur between structures which make up the community edge, to encourage passers-by to take inviting glimpses inside Lionshead. In addition, buildings along edges should be scaled according to nearby structures. Architectural lanouaqe should be used to offer a consistent imaoe of Lionshead from the outside-prooortions of buildinqs and the wavs in which thev are detailed need to reflect the overall imaoe found within the communitv, and "loud." self-oromotino buibinqs which reference onlv' themselves should be avoided. 8.4.1.3 PedestrianStreets Width-to-Height Relationships Ratios of width to height at pedestrian streets and other outdoor spaces are crucial to the success of those spaces. While ideas of comfortable, inviting scale differ greatly between cultures and individuals, for the purposes of these Guidelines, European mountain antecedents'-integrated with our Colorado resort location-have been used as the basis for determining "comfort." With this in mind, pedestrian streets shall be designed with cross-sections exhibiting 1:1/2 to 1 :1 % widthto-heioht ratios. DEVIATION #1 : Portions of the realigned East Lionshead Circle are 20 feet in width, while the Gonference Cente/s southern elevation eave height is 84 feet in height (i.e. ration in excess ot 1:41. Staff Comment While the Lionshead Redevelopment Master Plan identifies a pedestrian walUpath along East Lionshead Circle, staff does not believe this to be an exclusively pedestrian street. Therefore, staff does not believe this provision is applicable to this proposal and complies with the seven review criteria. 8.4.2 Architecture 8.4.2.1 lntroduction The architectural portion of these Guidelines is intended to provide a unified. conceptual framework usino historical alpine references. lt is imperative thal the redevelopment effort address specific architectural design considerations generated by the location, climate, and surrounding environment-such as addressing views, using indigenous building materials, and reflecting the alpine heritage. However, within this framework, the architectural language of buildings within Lionshead should strive to reinterpret its heritage and look to the future, instead of simply mimicking the past. \ 8.4.2.3 BuildingHeight Remaining Building Frontage Building faces that do not meet the special site criteria of the sections above may have those faces must step back a minimum of 12'. To the extent possible, all new and redeveloped buildings in Lionshead should avoid "turning their backs" on other buildings or important pedestrian corridors. However,. it must be acknowledged that very few buildings have prime frontage on all sides and almost all buildings will have different programmatic requirements and visual characteristics on their different faces. Toward that end, a building's greatest vertical mass and "back of house" functions should occur on the frontage with the least volume of pedestrian traffic. In addition, components of a building with the greatest vertical mass should be oriented north-south to minimize the blockage of southem views and sunlight. It is critical to note that the 60' maximum initial eave height does not allow for an unarticulated, flat buiHing face from grade to 60'. The horizontal and vertical maximum unbroken building face requirements, all other guidelines contained in this chapter and the Master Plan, and DRB review and approval, shall still apply.' DEVIATION #2: The Gonference Genteds southern elevation eaves exceed 60 feet in height. Staff Recommendation: While the proposed southern elevation eave does exceed 60 feet in height, a deviation from this guideline is in keeping with the architectural character ofthe structure. Staff believes the proposed balconies and the recently added entry roof element meet the intent of this guideline. Staff believes this deviation complies with the seven review criteria. Wall Surface Griteria Notwithstanding the previous height and setback requirements, there shall be no vertical wall face greater than 35' on a building without a secondary horizontal step in the building face (the horizontal step may be a cantilever or a setback). This requirement is intended to prevent large, unbroken planes in the middles of building faces, to further mitigate the visual impact of building height, and to provide for higher quality and more interesting articulation of structures. While many instances will necessitate a distance of at least 24" for this movement. it shall be incumbent upon the developer to demonstrate that the intent of this requirement has been met. Maximum Heights Maximum height is defined as the distance from existing or finished grade-whichever is more restrictive-to the ridge of the nearest primary roof form to that grade. With this in mind, the Averaqe Maximum Heiqht of anv buildinq shall not exceed 71'. Notwithstanding the notion of Average Maximum Height, the Absolute Maximum Heioht of anv buildinq shall not exceed 82.5'. Absolute Maximum I Height shall be determined by interpolating existing or finished grade through the building footprint and measuring the vertical distance from the ridge of the highest primary roof form to the imaginary plane created by the interpolated grades. DEVIATION #3: The proposed Conference Genter exceeds the average maximum height and the eaves of the surrounding roof element exceed the absolute maximum height. Staff Recommendation: This property is zoned General Use and the building height standards are determined by the Planning and Environmental Commission; however, this site is surrounded by properties zoned Lionshead Mixed Use I District which must comply with the height guidelines of the Lionshead Redevelopment Master Plan. While Staff believes a deviation from the Average Maximum Height requirement for the primary roof over the conference center ball room meets the seven review criteria; Staff does not support any deviations from the Absolute Maximum Height guideline. The primary roof over the ball room complies with this standard; however, the roof south elevation roof eaves exceed the 82.5 foot limit by a few feet. Staff believes this proposal should be modified to conform to the Absolute Maximum Height guideline to be in keeping with the character of the neighborhood. 8.4.2.4 Exterior Walls General Exterior walls within Lionshead shall be desiqned with clear definition of base. middle. and lop. This organizing principle will weave the separate pieces of the community into a consistent fabric. The tripartite strategy of base, middle, and top will establish key datums, or special horizontal layers, within the community which reinforce the form, massing and height guidelines described earlier. To this end, the three-part definition of buiHings shall relate directly to organizing principles such as existing datums, architectural elements such as storefront colonnades and awnings (where applicable), and massing strategies such as building setbacks and maximum heights. This strategy can relate to form and massing principles through the development of street-level setbacks defining the bases of buildings where appropriate, and minor setbacks relating to the middles and tops of buildings. The bases of buildings should be visually dynamic to heighten the pedestrian experience. In addition, their interface with the topography of the site is crucial, as they act as the transition zones between man- made structures and natural grade. Visual dvnamics at streel level are most effectivelv accomolished throuoh the introduclion of secondarv forms. materials. colors and detailino. However, the use of indigenous materials at the primary elements (see following sections for definitions) is critical in tying buildings to their sites. Rhythm and order should be introduced to guide the traveler through the streetscape, and offer an enhanced sense of movement through Lionshead. To reinforce this intent, street-level walls shall not span more than 30 feet horizontally without significantly varying at least 2 of the following 5 characteristics: o Massing or Height. Material, Fenestration, or Color When massing or height are varied, buildings with street-level walls may vary material, fenestration, or color to meet the 3O-fool span requirement; however, if massing or height are not varied within 30 feet, material, fenestration, and color must be varied. Existing buildings may disregard the 3O'-maximum horizontal wall guideline if their structural bays or other organizing elements exceed 30', provided that the distance over 30' falls within reasonable limits. An existing building with 36' structural bays, for instance, is not required to further divide those bays; however, an existing building with 48' structural bays may be required to divide those bays into 24' sections, depending upon the nature ofthe pedestrian street frontage. The middles of buildinqs within Lionshead shall read as "quiet" masses when compared to buildinq bases and roofs, and should act as a unifvinq backqrbund throuqhout the communitv. This should be done through the use of simple materials, such as stucco, and more consistent, repetitive fenestration and detailing (see Sections 8.4.2.5 and 8.4.2.9). Building middles should not be designed as less important, banal elements, but rather as elements which present interest and articulation through subtle detailing-through fenestration, shutters, trim, and the like-instead of massing. The tops of walls shall be desiqned to comfortablv enoaqe their oitched roofs. without the abruot chanqes in form and massinq so commonlv found in structures with primarilv flat roofs. Walls should also be used to visuallv reduce roof heiqhts. throuqh the careful desiqn of lowered olate heiqhts and inteqrated dormers. which help to merqe wall olanes with roof Torms and interlock buildinq masses with roof masses. The tops of buildinqs shall be capped with well-prooortioned. pitched roofs. actino as the uppermost unifvinq imaqe within the architectural fabric of Lionshead. Roofs viewed from oedestrian streets should nearlv disapoear from view as travelers approach. due to their oitches relative to oround-level siqhtlines. However. viewed from a distance. roof forms within Lionshead should offer a consistent roofscaoe to the observer within the communitv or on the mountain adiacent to it. Guidelines which direct the design of the roofscape are described in Section 8.4.2.7. Deviation #4: The proposed architecture ofthe Conference Center does not have a clearly defined tripartite design of base, middle, and top. Staff Recommendation: Based upon input from several public hearings and direction from the Town Council, the proposed conference center has been designed with an organic, non-traditional Vail, style of architecture. Therefore, the building does not as clearly as defined base, middle, and top as many other structures in Vail. Staff believes the deviation from this guideline is necessary for an aftractive implementation of this unique, organic architectural style. Staff believes this deviation complies with the seven review criteria. Mabrials (General) As mentioned earlier, building materials should be carefully selected to recall the heritage of our alpine antecedents, yet look fonrvard to the vision of Lionshead as a modern resort community. The specific requirements and limited palette of major building materials described herein are intended to reinforce the visual harmony envisioned for the community and act as additional unifying thread for the resort. Materials used at primary buibing elements-defined as those which exceed 500 square feet (SF) in wall surface area-shall recall and relate to the indigenous materials of the area and enhance the sense of our Colorado mountain resort heritiage. They are described below according to their most appropriate locations within the tripartite order of individual structures. Secondary building elements, or those which c,over an area of 500 SF or less, may be comprised of varying materials to add design flexibility, encourEtge individual expression, and enhance visual interest. They are not specifically listed within these Guidelines, but may include materials such as painted steel, canvas and similar textiles, colored unit masonry, and the like. Within this framework, creative use of materials is encouraged, but 'patchwork" designs of inconsistent material locations or pattems should be avoided. All secondary building elements will be approved at the discretion of the reviewing body. Base Mabrials Malerials selected for the bases of buildings must balance the transparency required at retail shopfronts with the strong, anchoring elements needed to tie buildings to their sites. That is, they must successfully integrate the notions of mass wall and frame wall. In addition, they should offer both large- and small-scale texture at the ground plane, to add varying levels of inlerest and heighten the pedestrian experience. With this in mind, building bases shall be primarily constructed of individual pieces or unit materials such as stone veneer. When using stone, veneers should be selected which lend authenticity to mass walls-thin veneers or those which appear as mere surface applique should be avoided. Battering may be used as an additional-but optionaliesign tool to visually strengthen the bases of structures. As mentioned earlier, secondary elements within building bases may incorporate accent materials, but these materials should be carefully selected to act in concert with the rest of the architecture. Shopfronts and other special street-level amenities have the most latitude with respect to material selection, but can be very successful if constructed of hand-crafted. durable materials. These l0 types of materials can hold up to the careful scrutiny of the street-level observer, along with the physical abuse common to public ways. Acceptable accent materials include-but are not limited to-wood, wrought iron, forged or formed metals, and etched glass. MiddleWall Materials The middles of buildinqs shall be constructed of neutral field materials such as true stucco. EIFS. or wood. These tvoes of materials helo to establish the "quiet" or "backqround" vertical surfaces necessary at the maior wall planes which tvpicallv make uo the bulk of structures. ln addition. thev offer an interestinq differencg between the dvnamic nature of buildino bases and the more repetitive. subtle oatterns of buildinq walls above street level. Materials such as stucco should be designed as an expression of mass, rather than infill between structural members. Where building walls meet roofs, materials which successfully integrate the tops of buildings to their middles, such as wood in the form of brackets, rafter tails, and the like, are most effective. DEVIATION #5: The architectural design of Conference Genter does not include a clearly defined "middle" and does not incorporate the use of stucco, EIFS, or wood to create a "quiet" middle building mass. Staff Comment Based upon input from several public hearings and direction from the Town Council, the proposed conference center has been designed with an organic, non-traditional Vail, style of architecture, Therefore, the building does not as clearly as defined base, middle, and top as many other structures in Vail. Staff believes the deviation from this guideline is necessary for an attractive implementation of this unique, organic architectural sgrle. Staff believes this deviation complies with the seven review criteria. Colors Building colors for structures within Lionshead should be chosen to blend structures with the mountain environment, while offering visual and psychological warmth to observers. To this end, earth tones and other low-intensity colors derived directly from the surrounding mountains should be used on primary building elements, defined as those which cover more than 500 SF. Earth tones include hues such as off-whites, beiges, tans, and light grays, introduced in shades slightly darker than their natural counterparts. Colors inherent to the materials used, such as natural stones and naturally-weathering woods, generally offer the hues and textures most desirable within Lionshead, and such materials should not be painted. However, integrally-colored concrete, stucco, and semi-transparent wood stains are acceptable as well. In an effort to limit the palette of colors used on buildings and avoid the 'patchwork" effect, no more than three colors should be used on primary building elements. il I 8.4.2.6 Balconies, Guardrails, and Handrails Location and Size Balconies should be carefully located with respect to their orientation to the sun, involvement with public spaces, and snow and watershed from structures above and onto structures or passers-by below. They should be sized as outdoor rooms, with ample space for outdoor furniture and other amenities, or merely as small, private parapets used as "step-outs" to allow fresh air into the adjacent room. False balconies and balconies which straddle these two roles should be avoided, as they tend to lack the benefits of either and are often left unused. Proper location and size will ensure that balconies become animated spaces, rather than outdoor storage areas. As animated spaces, their placement in public plazas and pedestrian streets- straddling the semi-private and public domains-will infuse those spaces with the vitality needed to draw visitors to Lionshead. Balconies which face service alle;a or are located within other socially "dead" spaces, or are susceptible to water or snowshed are generally unsuccessful spaces and should be avoided in Lionshead. The intent of this Section is to infuse public spaces with the energy of occupied balconies, and encourage designers to avoid the design of lifeless balconies which remain unoccupied and therefore detract from public spaces. Matertals and Designs Custom designs for balconies, guardrails, and handrails offer the opportunity for truly creative expression within these Guidelines, and unique design solutions are encouraged. Aporoved materials for orimarv elements such as quardrails. handrails. oosts. and suooort brackets include stucco-covered walls (for ouardrails onlv). naturallv weather-resistant woods, wrouoht iron and other decorative metals. and steel. Materials such as olass. olastic. oipe rails. and metal oanels are stronolv discouraqed. Secondary elements such as pickets and ornamental detailing may use other materials not listed above but will be reviewed on a case-by-case basis. Materials which meet the intent of the Guidelines and work in harmony with the architectural language of the building can lead to positive solutions, but all secondary building materials will be approved at the discretion of the reviewing body. Drainable balconies<r those which shed water off them via waterproof membranes as opposed to letting water trickle through them-shall be designed whenever other balconies, pedestrian slreets, or other public ways are exposed to water or snowshed from those balconies. Placement of the drain systems should be carefully considered to avoid passers-by below. Non-drainable balconies may be used in all other locations and should be constructed of weather- resistant woods or omamental metals. Within these general parameters, balcony, guardrail, and handrail designs should be patterned after a rational order of struclure and 12 detail. Primary structural or decorative members should be in proportion to the balconies they are supporting, which in turn should relate to the overall building scale. An honest, straight-forward expression of structure should be sought whenever possible, avoiding design faux pas such as stucco-covered beams or grossly undersized brackets. DEVIATION #6: The balconies of the conference center have a copper facade. Staff Recommendation: Based upon input from several public hearings and direction from the Town Council, the proposed conference center has been designed with an organic, non-traditional Vail, style of architecture. A balcony fagade of stucco, wood, or iron would not be as complimentary to the architectural style of the building as the proposed copper material. Staff believes this deviation complies with the seven review criteria. 8.4.2.7 Roofs General In keeping with the spirit of the area's mountain architecture, primary roofs within Lionshead are to be predominantly gables and hips, with sheds or flat roofs permitted at smaller, secondary roofs. Primary roofs are defined as roofs which cover more than 500 SF of roof area, while secondary roofs are those which cover 500 SF of roof area or less. Secondary roofs which occur at logical breaks in building massing may exceed 500 SF if the general intent of fragmented forms and visual harmony is met. Free-standing sheds and butterfly roofs are not permitted. Mansard roofs are permitted on buildings where pitched roofs would be impractical, if the mansards are of similar form, pitch, material, color, and detail to other roofs within the community (and identified within these Guidelines). lf used, these types of roofs should be considerate not only of views from the pedestrian street, but also those from the ski mountain. To this end, areas of flat roof within the slopes of the mansard shall be limited to the practical minimum, and the materials for the flat roof shall be black or in a color to blend with the sloped roof. In addition, rooftop equipment within the flat areas shall be painted to blend with the roof material (see "Miscellaneous Equipment" Section to follow). The overall image for Lionshead takes its cue from the simple, fragmented, gabled roof forms of European alpine villages, where views of the roofscapes from the mountains are paramount. All new construction shall comply with the following roof criteria. Substantial expansions and renovations shall also adhere to these Guidelines, along with the remaining portions of the building which are not being expanded or renovated (see exceptions above, in Sections 8.3.1, 8.3.4.2, and later in this Section). Roof framing shall be expressed wherever possible, particularly through exposed ridge beams, outriggers, rafter tails, and fascia boards. 13 Dimensional Guidelines Roofs should be constructed with 301 minimum eave and rake overhangs, with dimensions dependent upon overall building size. Secondary roofs may have overhangs as small as 18", but should work with the overall scale of the roofscape. Ridge beams and outriggers should be of visually sturdy members (6x or 8x material for wood, and equivalent sizes for other materials), sized to support rafters and overhangs; decorative end cuts or pattems are encouraged. Rafter tails shall also appear sturdy (2x or 3x material for wood) and be exposed to express structure. Eave and rake fascias shall be wide enough to screen end profiles at metal roofs, and to offer a consistent image with respect to structural roof members. Pitch Roof oitches for orimarv roofs shall be from 6:12 to 12:12. inclusive. Pitch breaks are permitted when thev occur at architecturallv aoprooriate locations such as olate lines, chanqes in plane, etc. To add variefu to the Lionshead roofscaoe. secondarv slooed roofs mav have oitches ranqinq from 4:12 to 12:12. and flat roofs mav have limited use as secondarv forms. Existino structures with esoeciallv laroe footprints mav deviate from the oitch reouirements if thev meet the overall intent of the roof ouidelines and are responsive to views from both the pedestrian street and the ski mountain. Steeo mansard roofs which exceed the 12:12 maximum pitch criteria are not encouraqed, but mav be necessarv in certain instances when excessive buildinq dimensions make the 12:12 oitch requirement imoractical. These buildinqs will be handled on a case-bv-case basis. and evaluated on intent ralher than ouantitative criteria. DEVIATIONS #7: The proposed Conference Center roof includes a large low- pitched roof of the center of the conference center's ball room plus an organically shaped, eave line/roof form. The unique Conference Center roof form is not a gable or hip style, nor does it conform to the recommended roof pitch ranges. Staff Recommendation: Based upon input from several public hearings and direction from the Town Gouncil, the proposed conference center has been designed with an organic, non-traditional Vail, style of architecture. Staff believes the deviation from this guideline is necessary for an attractive implementation of this unique, organic architectural style. Staff believes this deviation complies with the seven review criteria. Materials and Colors Primary roofs shall be covered with a limited palette of unit materials to present a coherent image for Lionshead. Approved materials for primarv roofs include-but are not limited to-rnetal shinoles. cementitious shinoles, concrete tiles. wood shakes or shinoles, and hiqh<ualilv asphalt shinqles which offer acceptable colors and depth. Metal shinoles mav be of copper (16 ozlSF minimum weiqht). terne metal. or other materials with natural patina. Secondarv roofs mav be covered with metal oanels. in corruoated. rolled. or standinq seam t4 t profiles. Primary roofs shall be in neutral, earth-tone colors, with brown or gray tones-bright colors or reflective materials are not permitted. Roofs may incorporate blends to achieve desired colors- on-site mock-ups are required when blends are proposed. At retail levels, accent colors are permitted for secondary roofs to add vitality to the streetscape. Changes in roof materials or colors shall take place in logical locations, such as changes in pitch or changes in plane. DEVIATIONS #8: While selection of the proposed building colors and materials has not yet been finalized by the applicant, an EPDM roofing material is being considered for the main roof over the conference center ball room. Staff Recommendation: Based upon input from several public hearings and direction from the Town Council, the proposed conference center.has been designed with an organic, non-traditional Vail, style of architecture, Staff believes the deviation from this guideline is necessary for an attractive implementation of this unique, organic architectural style. Staff believes this deviation complies with the seven review criteria. IV. CRITERIA AND FINDINGS It shall be the burden of the applicant to demonstrate to the satisfaction of the Town of Vail Planning & Environmental Commission following a recommendation from the Design Review Board that: The request for design deviations are in compliance with the purposes of the zone district; and The proposal which includes the design deviations is consistent with applicable elements of the Lionshead Redevelopment Master Plan; and The proposal which includes the design deviations does not have a significant negative effect on the character of the neighborhood; and The proposal substantially complies with other applicable elements of the Vail comprehensive plan; and The design deviation meets or exceeds the intent of the specific design slandards as prescribed in Section 8.4; and, A public benefit is achieved as a result of the design deviation; and, The design deviation furthers the goals, objectives and purposes as stated in Sections 2.3, 2.5 and 8.2 of the Lionshead Redevelopment Master Plan. 1. 2. 3. 4. 5. b. 7. l5 , V.STAFF RECOMMENDATION Staff is recommending approval of the proposed deviations from the Lionshead Redevelopment Master Plan's Architectural Design Guidelines, with the exception of deviations from the Absolute Maximum Height (deviations #3). Should the Design Review Board choose to approve the proposed deviations from the Architectural Design Guidelines of the Lionshead Redevelopment Master Plan, Staff recommends the Board make following motion: "The Design Review Board foruards a recommendation of approval to the Planning and Environmental Commission for prcposed deviations from the Architectural Design Guidelines of the Lionshead Redevelopment Master Plan to allow for a new conference center, subject to the following findings: 1. That the request for design deviations are in compliance with the purposes of the zone districf; and 2. That the proposal which includes the desrgn deviations is consistent with applicable elements of the Lionshead Redevelopment Master PIan; and 3. That the proposal which includes the design deviations does not have a significant negative effect on the character of the neighborhood; and 4. That the proposal substantially complies with other applicable elements of the Vail comprehensive plan; and 5. That the design deviation meets or exceeds the intent of the specific design standards as prescribed in Section 8.4; and, 6. That a public benefit is achieved as a resuft of the design deviation; and, 7. That the design deviation fufthers the goals, objectives and purposes as stated in Sec0bns 2.3, 2.5 and 8.2 of the Uonshead Redevelopment Master Plan." 16 VAIL CONFERENCE CENTER REQUEST FOR DESIGN VARIATION APPROVAL 1.0 PT]RPOSE The purpose of this application is to request approval for deviations from the Lionshead Redevelopment Master Plan Architectural Guidelines for the proposed Vail conference center. Chapter Eight of the Lionshead Redevelopment Master Plan consists of a set of architectural guidelines for the Lionshead study area. The guidelines include a procedure for review and approval of variations and criteria with which to evaluate proposed variations. This application provides information about design objectives and supporting evidence that the proposed Vail conference center design meets the criteria required for a recommendation of approval of the proposed variations by the Design Review Board and the Planning and Environmental Commission. 2.0 INTRODUCTION The initial task of the conference center design team was to create a master plan for the proposed development as recommended in the Lionshead Redevelopment Master Plan. The purpose of this master plan is to ensure that development of a conference center on the charter bus lot would be in harmony with the overall Lionshead Redevelopment Master Plan. The newly developed document, entitled The Master Planfor the Vail Confererrce Center and the Lionshead Parking Structure, was submitted for staff and PEC review with the conditional use permit application for the conference center. The staff have determined that the conference center proposal is in overall conformance with the Lionshead Redevelopment Master Plan but will require approval of a variation from the architectwal design guidelines. The procedure and criteria for review of a request for design variations are discussed in detail in a later section of this report. The conference center site is surrounded by an eclectic mix of existing condominium and civic buildings, some of which are architecturally undistinguished and none of which conforms to any consistent style or theme. The site is not part of the Lionshead core area, where greater consistency in architectural theme is a desirable objective. It adjoins a 26- year-old precast concrete parking structue that no one wishes to emulate but that requires an effort to respond with respect, to provide functional connections between the buildings, and to make their juxtaposition tolerable in the event that redevelopment of the parking structue proves unfeasible in the foreseeable future. In this eclectic context, the most important architectural qualities of the conference center and any future modification of the parking structure may be their contribution to the creation of memorable landmarks, a more dynamic street edge and a stronger connection to Lionshead. The Lionshead Master Plan study area included the area defined as a "civic plaza" (the library, Dobson Ice Arena and the charter bus lot), as well as a portion of the single- family residential neighborhood of Forest and Beaver Dam Roads. However, the adopted architectural guidelines contained in the Lionshead Redevelopment Master Plan were intended to focus primarily on the development and redevelopment of mixed-use commercial and residential projects in the Lionshead core area. As such, these guidelines are not particularly applicable to public buildings to be located in the civic plaza area. The need for variation approval is not likely to be specific to the conference center site alone; any remodel or upgrades to the Dobson Ice Arena or the library would likely also be required to request approval of design variations. The Town Council's desire for a civic icon and the specific single use of this building as a conference center suggest that the foremost aim of its architectural design should be to create a landmark building with a unique architectural identity that is both inspired by its natural surroundings and compatible with the general design objectives and vision for Lionshead as outlined in the Lionshead master plan. The vision statement that introduces Chapter 8 of the Lionshead Redevelopment Master Plan, "Architectural Design Guidelines," articulates this general vision for the character of Lionshead: The architecture of Lionshead is envisioned as a unified composition of buildings and public spaces based on the timeless design principles of form, scale, and order, made responsive to their setting and environment. It is not envisioned as a stict dictation of a specific "style" or "theme".... The new image for Lionshead should move towards the future - using historical alpirw references and Vail Village as antecedents. This design framework will allow individual property owners freedom of expression...while establishing and maintaining an overall unifying character and image for the entire community. In addition, it is paramount that the redevelopment effort address specific design considerations generated by the location, climate, and surrounding environment, such as addressing views, using indigenous building materials, and reflecting the alpine heritage....However, within this framework, the architectural language of buildings in Lionshead should strive to reinterpret its heritage and look to the future instead of simply rnimicking the past. Numerous specific design principles and design elements are mentioned in the architectural design guidelines as tools by which individual buildings can contribute to the vision for a renovated Lionshead. Many of these, such as: the relationship of the building's ground floor to the street, the creation of important public spaces, and the enhancement of pedestrian connections are relevant to the conference center design and have been successfully incorporated into the architectural design for the facility. In addition, the design team has been particularly careful to use appropriate natural materials, colors and detailing in the design of the building. There are, however, several specific elements of the Lionshead Redevelopment Master Plan Design Guidelines with which the proposed conference center is unable to comply, owing to the type and volume of interior spaces required by the development program for the facility. In particular, this application requests approval of variations from Section 8.4.2.3 (building height, building eave design, wall surface criteria), Section 8.4.2.3 (exterior walls), and Section 8.4.2.7 (roofs). Aside from these variations, the design team feels confident that the architectural design and detailing of the conference center respond in a satisfactory manner to the intent of the architectural design guidelines in the Lionshead master plan. Flexibility in the application of the design guidelines will allow the building to meet many of the other goals and objectives of Lionshead Redevelopment Master Plan and of the Town of Vail. 3.0 CRITERIA, RESPONSE AND PROCEDURE FOR REVIEW The following text is quoted directly from the Lionshead Redevelopment Master Plan as amended by Resolution No. 18, Series of 2004. This paragraph outlines the procedure for review and approval of a variation from the design guidelines and then states each of the individual criteria. The design team response to each criterion follows in standard typeface. Section 8.3.3A Review Criteriafor Deviations to the Architectural Design Guidelines for N ew Develapment Similar to the irnplementation policies of the ADG prescribedfor existing structures, the Town has determined that there may be instances where flexibility in requiring strict cornpliance with the Guidelines for new development maybe in the best interest of the community and the furtherance of the goals and objectives stated in the Lionshead Refuvelopment Master Plan. That said, however, it is aclotowledged that such instances are rare and extraordinary, and shall be considered on a case-by-case basis. To aid in determining whenflexibility shall be afforded to new development from strict compliance with the Guidelines, review criteria have been establishcd. The degree of design deviation Jlexibility afforded to a developtnent project shall bear proportionately to the extent of the improvements proposed. For exarnple, a development application that proposes the construction of a new structure which hcludes the demolition of an existing structure or adds significant mass or volurne to a property, shall more fully comply with the prescribed Architectural Design Guidelines outlined in the master plan than an application which proposes a renovation or addition to an existing building. The following criteria shall be used by the Town of Vail Planning and Environmcntal Commission and Design Review Board to determine if deviartons to the Guidelines should be granted: It shall be the burden of the applicant to demonstrate to the satisfaction of the Town of Vail Planning and Environmental Commissionfollowing a recommendationfrom the Design Review Board that: 1 The requestfor design deviations is in cotnpliance with the purposes ofthe zone district: Applicant response: The charter bus lot, the Lionshead parking structure, Dobson Ice fuena and the town library are all zoned General Use. The common zone district to this area, designated in the Lionshead plan as a civic center, is an indication that the design guidelines written for the Lionshead mixed use core area may not be fully applicable here. Section l2-9c-l of the Vail Municipal Code states the purpose of the GU zone district. "The general use zone district is intended to provide sites for public and quasi-public uses which, because oftheir special characteristics, cannot be appropriately regulated by the development standards prescribed for other zoning districts, and for which development standards especially prescribed for each particular development proposal or project are necessary to achieve the purposes prescribed in Section 12-l-2 of this title and to provide for the public welfare. The general use zone district is intended to ensure that public buildings and grounds and certain types of quasi-public uses permitted in the district are appropriately located and designed to meet the needs ofresidents and visitors to Vail, to harmonize with surrounding uses, and, in the case of buildings and other structures, to ensure adequate light, ak, open spaces, and other amenities appropriate to the permitted types of uses." The purpose of the zone district directly supports the request for design variation by stating that all development standards should be reviewed on a case by case basis for "each particular development proposal". A similar statement regarding the applicability of the design guidelines to the civic center/general use zone district in the design guidelines would have been consistent with the purpose and intent of the GU zone district and with Section 5.1 of the Lionshead Redevelopment Master Plan. In this case, the desire for a single use large format building, a conference center, qeates an inherent conflict with some portions of the design guidelines as written. The request for design deviations is directly related to and in compliance with the purpose of the zone district. 2 Theproposalwhichincludes the designdeviations is consistentwith applicable elements of the Lionshead Redevelopment Master PIan; Applicant response The conference center proposal will be subject to the review and approval of a conditional use permit as required for all uses within the GU zone district. As a part of the conditional use process the applicant has submitted a site-specific development master plan document for review. It is the applicant's understanding that town staff have reviewed this document and the overall pmject plans as a part of the conditional use permit application review and have concluded that the conference center proposal meets all aspects of the Lionshead Redevelopment Master Plan with the exception of strict adherence to certain specific design guidelines. 3 The proposal which inclu.des the design deviations does twt have a significant negative effect on the character of the neighborhood; Applicant response: The applicant does not believe that the proposal will have a significant negative effect on the character of the neighborhood. The Master Planfor the Vail Conference Center and the Lionshead Parking Structure was prepared in part to anticipate any negative effects on the surrounding neighborhood and, through an exhaustive analysis, to propose modifications to existing infrastructure, vehicular circulation systems, and pedesffian connections to avoid such impacts. The conditional use permit review process includes a criterion relatively similar to this, and supporting evidence may be found in the concurrent conditional use permit application. 4 The proposal substantially complies with other applicable elements of thc Vail C ompr ehensiv e P lan ; Aoolicant resDonse: In order to assure that the proposed conference center complies with all of the applicable elements of the Vail Comprehensive Plan, the town staff and the design team initiated the master planning process that culminated in the draft Master Planfor thc Vail Conference Center and the Lionshead Parking Structure. This master plan document has been submitted to town staff and the Planning and Environmental Commission for review and may be used as a reference in the review of this application. It should be reviewed in its entirety to fully understand and evaluate the relationship of the conference center proposal to the existing town comprehensive plan. The conference center master plan concludes that the proposal does comply with all applicable elements of the comprehensive plan. 5 The design deviation meets or exceeds the intent of the specific design standards as prescribed in Section 8.4; Applicant response: While some of the quantitative criteria and specific elements of the approved design guidelines are not appropriate to the conference center/civic center use, the underlying intent of those criteria certainly is applicable. The designers of the conference center have paid great attention to the intent of those criteria and have attempted to meet or exceed the intent to the greatest degree possible given the design parameters of the facility and the constraints of the site. The design incorporates elements specifically targeted to the intent of the criteria, such as building material changes, the use of a "visor" roof system to reduce the perception ofbuilding mass and height, and balcony spaces to create horizontal segments that break up large facades in a manner similar to the "base-middle-top" concept described in the guidelines. A full description of the building architecture and its compliance with the intent of the guidelines is not best expressed here in a text format but will be explained by the designers with the use of the architectural plans, the model, the digital model and the other supporting graphics that have been prepared. 6 A public benefit is achieved as a result of the design deviation; Applicant response: The approval of the proposed design deviations will allow for a building that meets both the Town Council desire for an architectural icon in this location as well as an expressed community desire for facilities that will divenify and strengthen the local resort-based economy. In both its location and design, the conference center is specifically intended to be a public benefit by intensifying the appeal of Vail in the shoulder seasons, addrng important multi-purpose facilities and amenities to those already available in the community, and reinforcing the pedestrian connection between Lionshead and Vail Village. 7 The design deviationfurthers the goals, objectives and purposes as stated in Secrtons 2.3, 2.5 and 8.2 of the Lionshead Redevelopment Master Plan. Applicant response: The single most important purpose of the Lionshead Redevelopment Master Plan was to identify strategies and policy changes that would encourage the economic revitalization of an aging neighborhood. One strategy identified in the plan was the development of a large-scale public facility centrally located on the charter bus lot, where it could benefit from a synergistic relationship with existing civic facilities in the area and where it would he$ to knit together Vail's two village cores - an objective that is repeated in virtually every adopted planning document concerning town core areas. The conference center will directly support the goals, objectives and purposes of the above referenced sections of the master plan. a' TO: FROM: DATE: SUBJECT: MEMORANDUM Planning and Environmental Commission Community Development Department October 24,2005 A request for final review of a final plat, pursuant to Chapter 134, Minor Subdivisions, Vail Town Code, to allow for the subdivision of the Conference Center development site; final review of a conditional use permit, pursuant to Section 12-9C-3, Conditional Uses, Vail Town Code, to allow for a public convention facility and public parking facilities and structures; and final review of architectural deviations, pursuant to Section 8.3.3.A, Review Criteria for Deviations to the Architectural Design Guidelines for New Development, Lionshead Redevelopment Master Plan, to allow for a public convention facility and public parking facilities and structures, located at 395 East Lionshead Circle/ Lot 1, Block 2, Vail Lionshead Filing 1, Lot 3 and 5, Block 1, Vail Lionshead Filing 2, and setting forth details in regard thereto. Applicant: Town of Vail, represented by Pylman & Associates, Inc. Planner: Bill Gibson ll. SUMMARY The applicant, Town of Vail, represented by Pylman & Associates, Inc. and Fentress Bradburn Architects, Ltd., have submitted applications to allow for the construction of a Conference Center located at the "Charter Bus Lot" site adjacent to the Lionshead Parking Structure. Today's discussion will be a work session to allow the applicant an opportunity to discuss three issues with the Planning and Environmental Commission: parking, employee housing, and architectural revisions. Staff is requesting that the Commission listen to the applicant's presentation, ask questions, and provide preliminary direction to the applicant and Staff. Staff is then recommending the Planning and Environmental Commission table these items to the Gommission's November 14, 2005, public hearing. BACKGROUND On June 13 and June 20, 2005, the Planning and Environmental Commission held a work session to discuss the proposed Conference Center project. Staff and the applicant provided an introduction to the project at these work sessions. On July 6, 2005, the Design Review Board conceptually reviewed the proposed Conference Center project. The applicant presented an overview of the Conference Center design. The Design Review Board was general favorable toward the proposed design. The Board did note their concerns about the connection of the proposed Conference Center to the Lionshead Parking tn Structure, the need to upgrade the existing parking structure, the scale of the Conference Center's south elevation, the form and color of the proposed roof, the architectural treatment of the Conference Center's west elevation, and the cplors of the proposed wood and stone building materials. On July 11, 2005, the Planning and Environmental Commission held another work session to further discus the proposed Conference Center project. Staff and the applicant presented the Commission with additional information about the project. The following is a brief summary of the Commissioner comments about the proposal: r The perceived building heights of the building from the South Frontage Road and East Lionshead Circle are a concem.r The impact of the Conference Center's east driveway on the future redevelopment of the Vail Intemational Condominiums is a concern.r The buffer on the east side of the Conference Center needs to be enhanced.. A 3D computer model of the project and surrounding buiHings must be provided. o Parking is a significant problem in the Town of Vail today, and this project should not make conditions worse.o The HVS parking analysis is not an unbiased report.r The proposed 125 Conference Center parking spaces are not adequate.. Additional parking information is needed.o The proposed Conference Center must be reviewed as a stand-alone project and should be reviewed in the same manner as a private development.r The funds provided by Vail Resorts should be used to create new public parking, not to off-set the costs of the Conference Center project. . Traffic circulation and turning movements are still a concern.r The employee housing requirement should be met through a pay-in-lieu program.. The applicant must provide employee generation projections. r The proposed Conference Center should be designed and reviewed as an urban infill type project. On Jufy 25, 2005, the Planning and Environmental Commission held another work session to further discuss parking for the proposed Conference Center project. The applicant and representatives from HVS and FHU presented an overview of the Conference Center parking analysis. In conclusion, the Commission determined that 125 parking spaces were not adequate for the proposed Conference Center and the Commission directed the applicant to comply with the parking standards prescribed by the Town of Vail zoning regulations. On Septemb er 12, 2005, the Planning and Environmental Commission held another work session to further discuss parking for the proposed Conference Center project. ilt. On October 19,2005, the Design Review Board reviewed the applicant's proposed deviations from the Architectural Design Guidelines of the Lionshead Redevelopment Master Plan. The applicant is proposing deviations from the following guidelines: street width-to-building height relationships; roof eave heights, average and absolute building heights; exterior wall layering, materials, and colors; balcony materials; and roof pitch and materials. The Board voted 3- 0-1 (Dorward recused) to forward a recommendation of approval to the Planning and Environmental Commission for the proposed deviations. APPLICABLE PLANNING DOCUMENTS Staff has emphasized the pa*ing related code excerpts with bold text. TITLE 12, ZONING REGULATIONS, VAIL TOWN CODE Articte 12-9C: General Use (GU) District (in part) 12-9C-1: PURPOSE: The general use district is intended to provide sites for public and quasi- publlc uses which, because of their special characteristics, cannot be appropiately regulated by the development standards prescibed for other zoning districts, and for which development standards especially prescibed for each pafticular development proposal or project are necessaty to achieve fhe purposes prescibed in section 12-1-2 of this title and to provide for the public welfare. The general use dtsttzbf s intended to ensure that public buildings and grounds and certain types of quasi-public uses permitfed in the district are appropiately located and designed to meet the needs of residents and visitors to Vail, to harmonize with sunounding uses, an4 in the case of buildings and other structures, to ensure adequate light, ah, open spaces, and other amenities appropriate to the permitted types of uses. 1 2-9 C- 5 : D Ev E LO P M E Nr S TANDARDSi A. Prescibed by Planning and Environmental Commission: ln the general use district, development sfandards in each of the following categories shall be as prescribed by the planning and environmental commission: 1. Lot area and site dimensions. 2. Setbacks. 3. Building height. 4. Density control. 5. Site coverage. 6. Landscaping and site developmenL 7. Pa*ing and loading. B. Reviewed by Planning and Environmental Commission: Development standards shall be proposed by the applicant as a part of a conditional use permit application. Srfe speclfic develop;ment standards shall then be determined by the planning and environmental commission duing the ,l review of the conditional use request in accordance with the provisions of chapter 16 of this title. 1 2-9C-6: ADD ITt O NAL D EV ELOP M E Nr SIANDARDS: Additional regulations pertaining to site development standards and the development of land in the general use district are found in chapter 14 of this title. Article 12-10: Off Street Parking and Loading (in part) 1 2-1 G1 0: Parking Requirements Schedu/es; Off street parking requirements shall be determined in accordance with the followi ng sched u I e s: A. Schedule A applies to properties within Vail's "Commercial Core Areas" (as defined on the town of Vail core area parking maps I and ll, incorporated by reference and available for inspection in the office of the town clerk): Use Theaters, meeting rcoms, conference facilities Parkino Requirement 1.0 space per 165 sq. ft. of seating floor area 1 2-1 G20: SPECIAL REV tEW PROY,STONSi Notwithstanding the provisions of secfibn 12-1G18 of this Chapter, the Planning and Environmental Commission may approve a reduction to the number of required spaces specified in section 12-10-10 of this chapter, provided a report documenting the presence of unique parking characteristics is provided by a qualified consultant and the following findings are made by the Planning and Environmental Commission: A. The parking demand will be /ess fhan the requirements identified in section 12-10-10 of this chapter; and B. The probable long-term use of the building or structure, based on its design, will not generate additional parking demand; and C. The use or activity is part of a demonstated permanent program (including, but not limited to, "rideshare" programs, shuttle service, or staggered work shifts) intended to reduce parking demand that has been incorporated into the project's final approved development plan; and D. Proximity or availability of alternative modes of transportation (including, but not limited to, public transit or shuttle seruicesJ is significant and integral to the nature of the use or busrness activity. ln reaching a decision, the Planning and Environmental Commission shall consider suruey data submitted by a qualified transpoftation planning or engineering consultant. Projects under "special review" are subject to lv. additional scrutiny by the planning and environmental commission after development plan approval if it is deemed necessary to veify continued compliance with the afuve listed criteria. The maximum allowable reduction in the number of required spaces shall not exceed twenty five percent (25%) of the total number required under section 12-1G10 of this chapter. prscussroN The purpose of today's work session it to allow the applicant to discuss the following three items with the Planning and Environmental Commission: parking, employee housing, and recent changes to the architectural design. Staff encourages the Commission to ask questions and provide the applicant and Staff with any preliminary direction concerning these items. Parkinq Since the last PEC work session, the applicant has revised the parking proposal for the conference center. The applicant is no longer requesting a reduction in the parking requirement and will now be constructing seven more spaces than are required by Chapter 12-10, Off-Street Parking and Loading, Vail Town Code. Required Parking: Proposed Parking: 24il spaces (30,008 sq. ft. ballroom and 10,100 sq. ft. meeting rooms) 250 spaces (329 newly constructed spaces, 79 spaces to off-set those spaces eliminated by the new parking structure entrance) Emolovee Housinq The Town of Vail's requires development projects to provide housing lor 15o/o of all new employees. The Town of Vail calculates the number of new employees based upon the 1991 Rosall Remmen Cares "Employee Generation Rates" analysis, unless more specific, project specific employment information is available. The "Employee Generation Rates" analysis calculates employee generation for a conference center at a rate of 1 employee per 1,000 sq. ft. Based upon the ballroom and meeting room area of 40,108 sq. ft., approximately 40 new employees will be generated by the Conference Center project. Based upon 40 new employees, the conference center is required to provide housing for 6 employees. The applicant is not proposing to construct any new employee housing units. Instead, the applicant is proposing to provide the Town of Vail with the cash equivalent for housing 7 employees in a similar manner as the recently approved Westhaven Condominiums (aka "The Ruins"). The Town of Vail Housing Division believes the applicant's cash payment equivalent for housing 7 employees fulfills the employee housing requirement for the conference center project. Architectural Revisions Since the last PEC work session, the applicants have made several revisions to the proposed conference center project: . New south entry design. Stair and elevator connection to the Lionshead Parking Structurer Streetscape improvements to the south side of the Lionshead Parking Structurer Refinements to the landscaping design. Per the Design Review Board, continuation of the roof eave to the west building elevation V. STAFF RECOMMENDATION As this is a work session, the Commission is not being asked to take any formal action at this time. Staff is requesting that the Commission listen to the applicant's presentation, provide preliminary direction to the applicant and Staff, and then table these items to the Gommission's November 14,2005, public hearing. ---: