F12-0087 Calcs
Fire Station #2 Renovation 42 W. Meadow Dr. Vail, CO 81657 HYDRAULIC CALCULATIONS AND PRODUCT SUBMITTALS t (1 0 5 /2 DATE PHOENIX AUTOMATIC SPRINKLER 7684 S. BRENTWOOD ST. LITTLETON, CO 80128 720.922.9231 PHONE 720-922-9231 FAX .' ", Pr o j e c t N a m e : V a i l F i r e S t a t i o n # 2 Dr a w i n g N o . : Pr o j e c t L o c a t i o n : 4 2 W . M e a d o w D r . Ci t y : V a i l , C O CA L C U L A T I O N S U M M A R Y De s i g n A r e a s De s i g n A r e a Na m e Mi n . De n s i t y Ar e a o f Ap p l i c a t i o n Oc c u p a n c y Calculated Heads Mi n . Pr e s s u r e Hose Streams Tot a l W a t e r Pr e s s u r e @ So u r c e Margin To Source (g p m / f t ² ) (f t ² ) # (p s i ) (gpm) (g p m ) (p s i ) (psi) Mi n . Fl o w (g p m ) Ca l c . M o d e (M o d e l ) 1 Or d G r p 2 22 1 0 75 6 14 0 . 7 0. 2 26 1725024.7 21 . 6 De m a n d ( H W ) 2 Li g h t H a z a r d 24 7 5 39 5 . 9 14 1 . 5 0. 1 22 . 5 1110025.2 16 . 1 De m a n d ( H W ) Da t e 1 1 / 5 / 2 0 1 2 Page 1 Co p y r i g h t © 2 0 0 2 - 2 0 1 1 T y c o F i r e P r o t e c t i o n P r o d u c t s Fi l e : C : \ d w g \ p h o e n i x = v a i l f i r e s t a t i o n \ V a i l F i r e F P 1 . d w g Design Remote Area Name Remote Area Location Occupancy Classification Density (gpm/ft²) Area of Application (ft²) Coverage per Sprinkler (ft²) Number of Calculated Sprinklers In-Rack Demand (gpm) Special Heads Hose Streams (gpm) Total Water Required (incl. Hose Streams) (gpm) Pressure at Source (psi) Type of System Volume - Entire System (gal) 1 Apparatus Bay Ord Grp 2 0.2 2210 130 17 0 250 756 114.5 Wet 89.1 gal Water Supply Information Date Location Source HYDRAULIC CALCULATIONS for 12/23/12 near site W1 Project Name : Vail Fire Station #2 Contract No. : Project Location: 42 W. Meadow Dr. City: Vail, CO Date: 11/3/2012 Name of Contractor: Phoenix Automatic Address: 7684 S. Brentwood St. Phone Number: 720-922-9231 Name of Designer: TEM Authority Having Jurisdiction: Vail Fire City: Littleton, CO 80128 E-mail: Job Information Contractor Information Notes Date 11/5/2012 Page 2Copyright © 2002-2011 Tyco Fire Protection Products File: C:\dwg\phoenix = vail fire station\Vail Fire FP1.dwg Jo b : V a i l F i r e S t a t i o n # 2 Di a g r a m f o r D e s i g n A r e a : 1 (Op t i m i z e d H ydr a u l i c S i m p l i f i e d ) No d e L a b e l s : Pi p e L a b e l s : Off Off Da t e 1 1 / 5 / 2 0 1 2 Page 3 Co p y r i g h t © 2 0 0 2 - 2 0 1 1 T y c o F i r e P r o t e c t i o n P r o d u c t s Fi l e : C : \ d w g \ p h o e n i x = v a i l f i r e s t a t i o n \ V a i l F i r e F P 1 . d w g Job : Vail Fire Station #2 Hydraulic Analysis for : 1 Water Supply Parameters Calculation Info Calculation Mode Hydraulic Model Fluid Name Fluid Weight, (lb/ft³) Fluid Dynamic Viscosity, (lb·s/ft²) Demand Hazen-Williams Water @ 60F (15.6C) N/A for Hazen-Williams calculation. N/A for Hazen-Williams calculation. Supply 1 : W1 Flow (gpm)Pressure (psi) 0 142 922 138 Inside Hose Flow (gpm) Outside Hose Flow (gpm) Additional Outside Hose Flow (gpm) Other (custom defined) Hose Flow (gpm) Total Hose Flow (gpm) 250 250 Hoses Ovehead Sprinkler Flow (gpm) InRack Sprinkler Flow (gpm) Other (custom defined) Sprinkler Flow (gpm) Total Sprinkler Flow (gpm) 506 0 0 506 Required Margin of Safety (%) W1 - Pressure (psi) W1 - Flow (gpm) Demand w/o System Pump(s) 10 114.5 506 N/A Sprinklers Other Date 11/5/2012 Page 4Copyright © 2002-2011 Tyco Fire Protection Products File: C:\dwg\phoenix = vail fire station\Vail Fire FP1.dwg Jo b : V a i l F i r e S t a t i o n # 2 Hydr a u l i c A n a l ysi s f o r : 1 Su p p l y Su p p l y ; S a f e t y P r e s s u r e Sy s t e m D e m a n d A d d . O u t . H o s e Fl o w , g p m Pressure, psi 15 0 14 0 13 0 12 0 11 0 10 0 90 80 70 60 50 40 30 20 10 0 S1 S2 13 7 . 3 5 2 D1 D2D2 D3 0 3 0 0 4 0 0 5 0 0 6 0 0 7 0 0 8 0 0 9 0 0 1 0 0 0 Da t e 1 1 / 5 / 2 0 1 2 Page 5 Co p y r i g h t © 2 0 0 2 - 2 0 1 1 T y c o F i r e P r o t e c t i o n P r o d u c t s Fi l e : C : \ d w g \ p h o e n i x = v a i l f i r e s t a t i o n \ V a i l F i r e F P 1 . d w g Job : Vail Fire Station #2 Hydraulic Analysis for : 1 Pressure (psi)Label Graph Labels Flow (gpm) ValuesDescription 0S1 142Supply point #1 - Static 922S2 138Supply point #2 - Residual 0D1 8.9Elevation Pressure 506D2 114.5System Demand 756D3 114.5System Demand + Add.Out.Hose Pressure (psi)Curve Name Curve Intersections & Safety Margins Flow (gpm) Safety MarginIntersection Pressure (psi)@ Flow (gpm) 569.6Supply140.4 24.7 756 536.3Supply; Safety Pressure 126.5 10.8 756 Open Heads Head Ref.DensityDensityK-Factor PressureFlowPressure (gpm/ft²)(gpm/ft²)(gpm/psi½)(psi)(gpm)(psi) Flow (gpm) Coverage (ft²) Required CalculatedHead Type 100 5.6 0.2 26 21.6 0.205 22.626.6130Overhead Sprinkler 101 5.6 0.2 26 21.6 0.206 22.826.7130Overhead Sprinkler 102 5.6 0.2 26 21.6 0.209 23.527.1130Overhead Sprinkler 103 5.6 0.2 26 21.6 0.234 29.430.4130Overhead Sprinkler 104 5.6 0.2 26 21.6 0.244 32.231.8130Overhead Sprinkler 105 5.6 0.2 26 21.6 0.2 21.626130Overhead Sprinkler 106 5.6 0.2 26 21.6 0.201 21.726.1130Overhead Sprinkler 107 5.6 0.2 26 21.6 0.204 22.426.5130Overhead Sprinkler 108 5.6 0.2 26 21.6 0.237 30.330.8130Overhead Sprinkler 109 5.6 0.2 26 21.6 0.247 3332.1130Overhead Sprinkler 110 5.6 0.2 26 21.6 0.212 24.227.6130Overhead Sprinkler 111 5.6 0.2 26 21.6 0.213 24.427.7130Overhead Sprinkler Date 11/5/2012 Page 6Copyright © 2002-2011 Tyco Fire Protection Products File: C:\dwg\phoenix = vail fire station\Vail Fire FP1.dwg 112 5.6 0.2 26 21.6 0.216 25.228.1130Overhead Sprinkler 113 5.6 0.2 26 21.6 0.235 29.830.5130Overhead Sprinkler 114 5.6 0.2 26 21.6 0.246 32.632130Overhead Sprinkler 115 5.6 0.2 26 21.6 0.291 45.737.9130Overhead Sprinkler 116 5.6 0.2 26 21.6 0.292 46.138130Overhead Sprinkler Date 11/5/2012 Page 7Copyright © 2002-2011 Tyco Fire Protection Products File: C:\dwg\phoenix = vail fire station\Vail Fire FP1.dwg Job : Vail Fire Station #2 Node Data Hydraulic Calculations / Fluid Delivery Time Analysis Node# Elev ft Type Hgroup K-Fact. Open/Closed gpm/psi½ Discharge Overdischarge gpm gpm Coverage Density ft² gpm/ft² Tot. Pres. Elev. Pres. psi psi Req. Pres. Req. Discharge psi gpm 105 19.25 Overhead Sprinkler HEAD 5.6 Open 26 0 130 0.2 21.6 -8.9 21.6 26 106 19.25 Overhead Sprinkler HEAD 5.6 Open 26.1 0.1 130 0.201 21.7 -8.9 21.6 26 107 19.25 Overhead Sprinkler HEAD 5.6 Open 26.5 0.5 130 0.204 22.4 -8.9 21.6 26 100 16 Overhead Sprinkler HEAD 5.6 Open 26.6 0.6 130 0.205 22.6 -7.3 21.6 26 101 16 Overhead Sprinkler HEAD 5.6 Open 26.7 0.7 130 0.206 22.8 -7.3 21.6 26 102 16 Overhead Sprinkler HEAD 5.6 Open 27.1 1.1 130 0.209 23.5 -7.3 21.6 26 110 13.5 Overhead Sprinkler HEAD 5.6 Open 27.6 1.6 130 0.212 24.2 -6.1 21.6 26 111 13.5 Overhead Sprinkler HEAD 5.6 Open 27.7 1.7 130 0.213 24.4 -6.1 21.6 26 112 13.5 Overhead Sprinkler HEAD 5.6 Open 28.1 2.1 130 0.216 25.2 -6.1 21.6 26 103 11.75 Overhead Sprinkler HEAD 5.6 Open 30.4 4.4 130 0.234 29.4 -5.2 21.6 26 113 11.75 Overhead Sprinkler HEAD 5.6 Open 30.5 4.5 130 0.235 29.8 -5.2 21.6 26 108 11.75 Overhead Sprinkler HEAD 5.6 Open 30.8 4.8 130 0.237 30.3 -5.2 21.6 26 104 11.75 Overhead Sprinkler HEAD 5.6 Open 31.8 5.8 130 0.244 32.2 -5.2 21.6 26 114 11.75 Overhead Sprinkler HEAD 5.6 Open 32 6 130 0.246 32.6 -5.2 21.6 26 109 11.75 Overhead Sprinkler HEAD 5.6 Open 32.1 6.1 130 0.247 33 -5.2 21.6 26 115 11.75 Overhead Sprinkler HEAD 5.6 Open 37.9 11.9 130 0.291 45.7 -5.2 21.6 26 116 11.75 Overhead Sprinkler HEAD 5.6 Open 38 12 130 0.292 46.1 -5.2 21.6 26 003 11 Node NODE 44.7 -4.8 007 11 Node NODE 45.3 -4.8 008 11 Node NODE 45.7 -4.8 011 11 Node NODE 50.2 -4.8 021 11 Node NODE 83.1 -4.8 023-O 8.76 Node NODE 85.2 -3.7 023-I 7.67 Node NODE 86.3 -3.2 024-O 6.88 Node NODE 86.8 -2.8 Date 11/5/2012 Page 8Copyright © 2002-2011 Tyco Fire Protection Products File: C:\dwg\phoenix = vail fire station\Vail Fire FP1.dwg Job : Vail Fire Station #2 Node Data Hydraulic Calculations / Fluid Delivery Time Analysis Node# Elev ft Type Hgroup K-Fact. Open/Closed gpm/psi½ Discharge Overdischarge gpm gpm Coverage Density ft² gpm/ft² Tot. Pres. Elev. Pres. psi psi Req. Pres. Req. Discharge psi gpm 024-I 4.07 Node NODE 102.4 -1.4 025-O 3.14 Node NODE 102.9 -0.9 025-I 1.89 Node NODE 109.7 -0.3 027 1 Node NODE 110.3 0.2 W1 1.33 Supply SUPPLY -506 114.5 0 Date 11/5/2012 Page 9Copyright © 2002-2011 Tyco Fire Protection Products File: C:\dwg\phoenix = vail fire station\Vail Fire FP1.dwg Hydraulic CalculationsJob : Vail Fire Station #2 PIPE INFORMATION Node 1 Node 2 Elev 1 Elev 2 (ft) K-Factor 1 K-Factor 2 (gpm/psi½) Flow added (q) Total flow (Q) (gpm) Nominal ID Actual ID (in) Fittings quantity x (name) = length (ft) L F T (ft) C Factor Pf per ft (psi) total (Pt) elev (Pe) frict (Pf) (psi) NOTES 1Path No: 105 106 19.25 19.25 5.6 5.6 26 26 1.5 1.728 10 0 10 120 0.0185 21.6 0 0.2 106 107 19.25 19.25 5.6 5.6 26.1 52.1 1.5 1.728 10 0 10 120 0.0672 21.7 0 0.7 107 108 19.25 11.75 5.6 5.6 26.5 78.6 1.5 1.728 2x(us.90)=11.29 17.5 11.29 28.79 120 0.144 22.4 3.2 4.1 108 109 11.75 11.75 5.6 5.6 30.8 109.4 1.5 1.728 10 0 10 120 0.2656 30.3 0 2.7 109 007 11.75 11 5.6 32.1 141.6 1.5 1.728 1x(us.Tee-Br)=11.29 1x(us.90)=5.64 11.13 16.93 28.07 120 0.4279 33 0.3 12 007 008 11 11 142.6 284.2 2.5 2.703 2 0 2 120 0.176 45.3 0 0.4 008 011 11 11 145.9 430.1 2.5 2.703 12 0 12 120 0.3791 45.7 0 4.5 011 021 11 11 75.9 506 2.5 2.703 1x(coupling)=1.55 2x(us.90)=18.65 43.94 20.2 64.15 120 0.5122 50.2 0 32.9 021 023-O 11 8.76 0 506 4 4.31 1x(coupling)=1.39 1x(us.90)=13.94 3.24 15.33 18.57 120 0.0528 83.1 1 1 023-O 023-I 8.76 7.67 0 506 4 0 1.08 0 1.08 0 0.519 85.2 0.5 0.6 Riser Manifold 023-I 024-O 7.67 6.88 0 506 4 4.31 1x(coupling)=1.39 0.79 1.39 2.19 120 0.0528 86.3 0.3 0.1 024-O 024-I 6.88 4.07 0 506 4 0 2.81 0 2.81 0 5.0421 86.8 1.2 14.2 C400 DblChk Z 024-I 025-O 4.07 3.14 0 506 4 4.31 1x(coupling)=1.39 0.93 1.39 2.32 120 0.0528 102.4 0.4 0.1 025-O 025-I 3.14 1.89 0 506 4 0 1.25 0 1.25 0 4.9164 102.9 0.5 6.1 WILKINS PRV 025-I 027 1.89 1 0 506 4 4.31 1x(coupling)=1.39 0.89 1.39 2.29 120 0.0528 109.7 0.4 0.1 027 W1 1 1.33 0 506 4 4.3 3x(us.90)=54.98 53.83 54.98 108.82 140 0.0401 110.3 -0.1 4.4 W1 114.5 Date 11/5/2012 Page 10Copyright © 2002-2011 Tyco Fire Protection Products File: C:\dwg\phoenix = vail fire station\Vail Fire FP1.dwg Hydraulic CalculationsJob : Vail Fire Station #2 PIPE INFORMATION Node 1 Node 2 Elev 1 Elev 2 (ft) K-Factor 1 K-Factor 2 (gpm/psi½) Flow added (q) Total flow (Q) (gpm) Nominal ID Actual ID (in) Fittings quantity x (name) = length (ft) L F T (ft) C Factor Pf per ft (psi) total (Pt) elev (Pe) frict (Pf) (psi) NOTES 2Path No: 100 101 16 16 5.6 5.6 26.6 26.6 1.5 1.728 10 0 10 120 0.0194 22.6 0 0.2 101 102 16 16 5.6 5.6 26.7 53.3 1.5 1.728 10 0 10 120 0.0702 22.8 0 0.7 102 103 16 11.75 5.6 5.6 27.1 80.5 1.5 1.728 2x(us.90)=11.29 14.25 11.29 25.54 120 0.1503 23.5 1.8 3.8 103 104 11.75 11.75 5.6 5.6 30.4 110.9 1.5 1.728 10 0 10 120 0.272 29.4 0 2.7 104 003 11.75 11 5.6 31.8 142.6 1.5 1.728 1x(us.Tee-Br)=11.29 1x(us.90)=5.64 11.13 16.93 28.07 120 0.4336 32.2 0.3 12.2 003 007 11 11 0 142.6 2.5 2.703 13 0 13 120 0.0491 44.7 0 0.6 007 45.3 3Path No: 110 111 13.5 13.5 5.6 5.6 27.6 27.6 1.5 1.728 10 0 10 120 0.0207 24.2 0 0.2 111 112 13.5 13.5 5.6 5.6 27.7 55.3 1.5 1.728 10 0 10 120 0.0749 24.4 0 0.7 112 113 13.5 11.75 5.6 5.6 28.1 83.4 1.5 1.728 2x(us.90)=11.29 11.75 11.29 23.04 120 0.1604 25.2 0.8 3.7 113 114 11.75 11.75 5.6 5.6 30.5 113.9 1.5 1.728 10 0 10 120 0.286 29.8 0 2.9 114 008 11.75 11 5.6 32 145.9 1.5 1.728 1x(us.Tee-Br)=11.29 1x(us.90)=5.64 11.13 16.93 28.07 120 0.4523 32.6 0.3 12.7 008 45.7 4Path No: 115 116 11.75 11.75 5.6 5.6 37.9 37.9 1.5 1.728 10 0 10 120 0.0372 45.7 0 0.4 116 011 11.75 11 5.6 38 75.9 1.5 1.728 1x(us.Tee-Br)=11.29 1x(us.90)=5.64 11.13 16.93 28.07 120 0.1348 46.1 0.3 3.8 011 50.2 Date 11/5/2012 Page 11Copyright © 2002-2011 Tyco Fire Protection Products File: C:\dwg\phoenix = vail fire station\Vail Fire FP1.dwg Hydraulic CalculationsJob : Vail Fire Station #2 PIPE INFORMATION Node 1 Node 2 Elev 1 Elev 2 (ft) K-Factor 1 K-Factor 2 (gpm/psi½) Flow added (q) Total flow (Q) (gpm) Nominal ID Actual ID (in) Fittings quantity x (name) = length (ft) L F T (ft) C Factor Pf per ft (psi) total (Pt) elev (Pe) frict (Pf) (psi) NOTES * Pressures are balanced to a high degree of accuracy. Values may vary by 0.1 psi due to display rounding. * Maximum Velocity of 28.29 ft/s occurs in the following pipe(s): (021-011) Date 11/5/2012 Page 12Copyright © 2002-2011 Tyco Fire Protection Products File: C:\dwg\phoenix = vail fire station\Vail Fire FP1.dwg Device GraphsJob : Vail Fire Station #2 Pressure vs. Flow Function Design Area: 1; Supply Ref.: W1; Supply Name:W1 Flow, gpm 0 20 0 30 0 40 0 50 0 60 0 70 0 80 0 90 0 92 2 Pr e s s u r e , p s i 160 150 140 130 120 110 100 90 80 70 60 50 40 30 20 10 0 139.2 psi @ 756 gpm (506 gpm+250 gpm add. out. hose) Pressure Loss Function Design Area: 1; BFP Ref.: 274 (C400 DblChk Z, Size = 4) Flow, gpm 0 25 10 0 15 0 20 0 30 0 40 0 50 0 60 0 70 0 80 0 Pr e s s u r e , p s i 22.5 17.5 12.5 7.5 2.5 14.2 psi @ 506 gpm Date 11/5/2012 Page 13Copyright © 2002-2011 Tyco Fire Protection Products File: C:\dwg\phoenix = vail fire station\Vail Fire FP1.dwg Device GraphsJob : Vail Fire Station #2 Pressure Loss Function Design Area: 1; Valve Ref.: 273 (WILKINS PRV, Size = 4) Flow, gpm 0 20 0 30 0 40 0 50 0 60 0 70 0 10 0 0 Pr e s s u r e , p s i 22.5 17.5 12.5 7.5 2.5 6.1 psi @ 506 gpm Pressure Loss Function Design Area: 1; Valve Ref.: 275 (Riser Manifold, Size = 4) Flow, gpm 0 10 0 30 0 40 0 45 0 50 0 60 0 70 0 80 0 90 0 10 0 0 Pr e s s u r e , p s i 1.667 1.167 0.667 0.167 0.6 psi @ 506 gpm Date 11/5/2012 Page 14Copyright © 2002-2011 Tyco Fire Protection Products File: C:\dwg\phoenix = vail fire station\Vail Fire FP1.dwg Design Remote Area Name Remote Area Location Occupancy Classification Density (gpm/ft²) Area of Application (ft²) Coverage per Sprinkler (ft²) Number of Calculated Sprinklers In-Rack Demand (gpm) Special Heads Hose Streams (gpm) Total Water Required (incl. Hose Streams) (gpm) Pressure at Source (psi) Type of System Volume - Entire System (gal) 2 White Room Light Hazard 0.1 2475 225 11 0 100 395.9 116 Wet 76 gal Water Supply Information Date Location Source HYDRAULIC CALCULATIONS for 12/23/12 near site W1 Project Name : Vail Fire Station #2 Contract No. : Project Location: 42 W. Meadow Dr. City: Vail, CO Date: 11/3/2012 Name of Contractor: Phoenix Automatic Address: 7684 S. Brentwood St. Phone Number: 720-922-9231 Name of Designer: TEM Authority Having Jurisdiction: Vail Fire City: Littleton, CO 80128 E-mail: Job Information Contractor Information Notes Date 11/5/2012 Page 15Copyright © 2002-2011 Tyco Fire Protection Products File: C:\dwg\phoenix = vail fire station\Vail Fire FP1.dwg Jo b : V a i l F i r e S t a t i o n # 2 Di a g r a m f o r D e s i g n A r e a : 2 (Op t i m i z e d H ydr a u l i c S i m p l i f i e d ) No d e L a b e l s : Pi p e L a b e l s : Off Off Da t e 1 1 / 5 / 2 0 1 2 Page 16 Co p y r i g h t © 2 0 0 2 - 2 0 1 1 T y c o F i r e P r o t e c t i o n P r o d u c t s Fi l e : C : \ d w g \ p h o e n i x = v a i l f i r e s t a t i o n \ V a i l F i r e F P 1 . d w g Job : Vail Fire Station #2 Hydraulic Analysis for : 2 Water Supply Parameters Calculation Info Calculation Mode Hydraulic Model Fluid Name Fluid Weight, (lb/ft³) Fluid Dynamic Viscosity, (lb·s/ft²) Demand Hazen-Williams Water @ 60F (15.6C) N/A for Hazen-Williams calculation. N/A for Hazen-Williams calculation. Supply 1 : W1 Flow (gpm)Pressure (psi) 0 142 922 138 Inside Hose Flow (gpm) Outside Hose Flow (gpm) Additional Outside Hose Flow (gpm) Other (custom defined) Hose Flow (gpm) Total Hose Flow (gpm) 100 100 Hoses Ovehead Sprinkler Flow (gpm) InRack Sprinkler Flow (gpm) Other (custom defined) Sprinkler Flow (gpm) Total Sprinkler Flow (gpm) 295.9 0 0 295.9 Required Margin of Safety (%) W1 - Pressure (psi) W1 - Flow (gpm) Demand w/o System Pump(s) 10 116 295.9 N/A Sprinklers Other Date 11/5/2012 Page 17Copyright © 2002-2011 Tyco Fire Protection Products File: C:\dwg\phoenix = vail fire station\Vail Fire FP1.dwg Jo b : V a i l F i r e S t a t i o n # 2 Hydr a u l i c A n a l ysi s f o r : 2 Su p p l y Su p p l y ; S a f e t y P r e s s u r e Sy s t e m D e m a n d A d d . O u t . H o s e Fl o w , g p m Pressure, psi 15 0 14 0 13 0 12 0 11 0 10 0 90 80 70 60 50 40 30 20 10 0 S1 S2 13 7 . 3 5 2 D1 D2D2 D3 0 3 0 0 4 0 0 5 0 0 6 0 0 7 0 0 8 0 0 9 0 0 1 0 0 0 Da t e 1 1 / 5 / 2 0 1 2 Page 18 Co p y r i g h t © 2 0 0 2 - 2 0 1 1 T y c o F i r e P r o t e c t i o n P r o d u c t s Fi l e : C : \ d w g \ p h o e n i x = v a i l f i r e s t a t i o n \ V a i l F i r e F P 1 . d w g Job : Vail Fire Station #2 Hydraulic Analysis for : 2 Pressure (psi)Label Graph Labels Flow (gpm) ValuesDescription 0S1 142Supply point #1 - Static 922S2 138Supply point #2 - Residual 0D1 13.2Elevation Pressure 295.9D2 116System Demand 395.9D3 116System Demand + Add.Out.Hose Pressure (psi)Curve Name Curve Intersections & Safety Margins Flow (gpm) Safety MarginIntersection Pressure (psi)@ Flow (gpm) 333.3Supply141.4 25.2 395.9 313Supply; Safety Pressure 127.3 11 395.9 Open Heads Head Ref.DensityDensityK-Factor PressureFlowPressure (gpm/ft²)(gpm/ft²)(gpm/psi½)(psi)(gpm)(psi) Flow (gpm) Coverage (ft²) Required CalculatedHead Type 200 5.6 0.1 22.5 16.1 0.1 16.122.5225Overhead Sprinkler 201 5.6 0.1 22.5 16.1 0.111 19.925225Overhead Sprinkler 202 5.6 0.1 22.5 16.1 0.101 16.322.6225Overhead Sprinkler 203 5.6 0.1 22.5 16.1 0.111 2025.1225Overhead Sprinkler 204 5.6 0.1 22.5 16.1 0.122 24.127.5225Overhead Sprinkler 205 5.6 0.1 22.5 16.1 0.103 17.123.2225Overhead Sprinkler 206 5.6 0.1 22.5 16.1 0.114 2125.6225Overhead Sprinkler 207 5.6 0.1 22.5 16.1 0.195 61.243.8225Overhead Sprinkler 208 5.6 0.1 22.5 16.1 0.129 26.728.9225Overhead Sprinkler 209 5.6 0.1 22.5 16.1 0.109 19.324.6225Overhead Sprinkler 210 5.6 0.1 22.5 16.1 0.12 23.427.1225Overhead Sprinkler Date 11/5/2012 Page 19Copyright © 2002-2011 Tyco Fire Protection Products File: C:\dwg\phoenix = vail fire station\Vail Fire FP1.dwg Job : Vail Fire Station #2 Node Data Hydraulic Calculations / Fluid Delivery Time Analysis Node# Elev ft Type Hgroup K-Fact. Open/Closed gpm/psi½ Discharge Overdischarge gpm gpm Coverage Density ft² gpm/ft² Tot. Pres. Elev. Pres. psi psi Req. Pres. Req. Discharge psi gpm 200 27.74 Overhead Sprinkler HEAD 5.6 Open 22.5 0 225 0.1 16.1 -13.2 16.1 22.5 202 27.74 Overhead Sprinkler HEAD 5.6 Open 22.6 0.1 225 0.101 16.3 -13.2 16.1 22.5 205 27.74 Overhead Sprinkler HEAD 5.6 Open 23.2 0.7 225 0.103 17.1 -13.2 16.1 22.5 209 27.74 Overhead Sprinkler HEAD 5.6 Open 24.6 2.1 225 0.109 19.3 -13.2 16.1 22.5 201 24.34 Overhead Sprinkler HEAD 5.6 Open 25 2.5 225 0.111 19.9 -11.5 16.1 22.5 203 24.34 Overhead Sprinkler HEAD 5.6 Open 25.1 2.6 225 0.111 20 -11.5 16.1 22.5 206 24.34 Overhead Sprinkler HEAD 5.6 Open 25.6 3.1 225 0.114 21 -11.5 16.1 22.5 210 24.34 Overhead Sprinkler HEAD 5.6 Open 27.1 4.6 225 0.12 23.4 -11.5 16.1 22.5 204 22.71 Overhead Sprinkler HEAD 5.6 Open 27.5 5 225 0.122 24.1 -10.7 16.1 22.5 208 24.32 Overhead Sprinkler HEAD 5.6 Open 28.9 6.4 225 0.129 26.7 -11.5 16.1 22.5 207 23.96 Overhead Sprinkler HEAD 5.6 Open 43.8 21.3 225 0.195 61.2 -11.3 16.1 22.5 139 23.29 Node NODE 26 -10.9 138 23.29 Node NODE 26.3 -10.9 137 23.29 Node NODE 26.7 -10.9 136 23.29 Node NODE 27.4 -10.9 135 23.29 Node NODE 29.5 -10.9 134 23.29 Node NODE 30.5 -10.9 058 23.29 Node NODE 66.2 -10.9 056 23.29 Node NODE 66.6 -10.9 019 11 Node NODE 96.8 -4.8 021 11 Node NODE 98.7 -4.8 023-O 8.76 Node NODE 100.2 -3.7 023-I 7.67 Node NODE 100.9 -3.2 024-O 6.88 Node NODE 101.3 -2.8 024-I 4.07 Node NODE 110.7 -1.4 Date 11/5/2012 Page 20Copyright © 2002-2011 Tyco Fire Protection Products File: C:\dwg\phoenix = vail fire station\Vail Fire FP1.dwg Job : Vail Fire Station #2 Node Data Hydraulic Calculations / Fluid Delivery Time Analysis Node# Elev ft Type Hgroup K-Fact. Open/Closed gpm/psi½ Discharge Overdischarge gpm gpm Coverage Density ft² gpm/ft² Tot. Pres. Elev. Pres. psi psi Req. Pres. Req. Discharge psi gpm 025-O 3.14 Node NODE 111.2 -0.9 025-I 1.89 Node NODE 114.1 -0.3 027 1 Node NODE 114.6 0.2 W1 1.33 Supply SUPPLY -295.9 116 0 Date 11/5/2012 Page 21Copyright © 2002-2011 Tyco Fire Protection Products File: C:\dwg\phoenix = vail fire station\Vail Fire FP1.dwg Hydraulic CalculationsJob : Vail Fire Station #2 PIPE INFORMATION Node 1 Node 2 Elev 1 Elev 2 (ft) K-Factor 1 K-Factor 2 (gpm/psi½) Flow added (q) Total flow (Q) (gpm) Nominal ID Actual ID (in) Fittings quantity x (name) = length (ft) L F T (ft) C Factor Pf per ft (psi) total (Pt) elev (Pe) frict (Pf) (psi) NOTES 1Path No: 200 201 27.74 24.34 5.6 5.6 22.5 22.5 1 1.08 14.41 0 14.41 120 0.1399 16.1 1.5 2 201 139 24.34 23.29 5.6 25 47.5 1 1.08 1x(us.Tee-Br)=5.76 4.41 5.76 10.17 120 0.5574 19.9 0.5 5.7 139 138 23.29 23.29 0 47.5 2 2.203 14 0 14 120 0.0173 26 0 0.2 138 137 23.29 23.29 47.7 95.1 2 2.203 6.65 0 6.65 120 0.0628 26.3 0 0.4 137 136 23.29 23.29 27.5 122.7 2 2.203 7.35 0 7.35 120 0.1005 26.7 0 0.7 136 135 23.29 23.29 48.8 171.5 2 2.203 11 0 11 120 0.1869 27.4 0 2.1 135 134 23.29 23.29 28.9 200.4 2 2.203 4 0 4 120 0.2496 29.5 0 1 134 056 23.29 23.29 51.6 252.1 2 2.203 1x(us.Tee-Br)=13.64 4x(us.90)=27.28 53.57 40.92 94.49 120 0.3816 30.5 0 36.1 056 019 23.29 11 43.8 295.9 2 2.203 1x(us.Tee-Br)=13.64 2x(us.90)=13.64 19.68 27.28 46.96 120 0.5135 66.6 5.3 24.1 019 021 11 11 0 295.9 2.5 2.703 1x(coupling)=1.55 8.36 1.55 9.91 120 0.1896 96.8 0 1.9 021 023-O 11 8.76 0 295.9 4 4.31 1x(coupling)=1.39 1x(us.90)=13.94 3.24 15.33 18.57 120 0.0195 98.7 1 0.4 023-O 023-I 8.76 7.67 0 295.9 4 0 1.08 0 1.08 0 0.1804 100.2 0.5 0.2 Riser Manifold 023-I 024-O 7.67 6.88 0 295.9 4 4.31 1x(coupling)=1.39 0.79 1.39 2.19 120 0.0195 100.9 0.3 0.0 024-O 024-I 6.88 4.07 0 295.9 4 0 2.81 0 2.81 0 2.8394 101.3 1.2 8 C400 DblChk Z 024-I 025-O 4.07 3.14 0 295.9 4 4.31 1x(coupling)=1.39 0.93 1.39 2.32 120 0.0195 110.7 0.4 0.0 025-O 025-I 3.14 1.89 0 295.9 4 0 1.25 0 1.25 0 1.789 111.2 0.5 2.2 WILKINS PRV Date 11/5/2012 Page 22Copyright © 2002-2011 Tyco Fire Protection Products File: C:\dwg\phoenix = vail fire station\Vail Fire FP1.dwg Hydraulic CalculationsJob : Vail Fire Station #2 PIPE INFORMATION Node 1 Node 2 Elev 1 Elev 2 (ft) K-Factor 1 K-Factor 2 (gpm/psi½) Flow added (q) Total flow (Q) (gpm) Nominal ID Actual ID (in) Fittings quantity x (name) = length (ft) L F T (ft) C Factor Pf per ft (psi) total (Pt) elev (Pe) frict (Pf) (psi) NOTES 1Path No: 025-I 027 1.89 1 0 295.9 4 4.31 1x(coupling)=1.39 0.89 1.39 2.29 120 0.0195 114.1 0.4 0.0 027 W1 1 1.33 0 295.9 4 4.3 3x(us.90)=54.98 53.83 54.98 108.82 140 0.0149 114.6 -0.1 1.6 W1 116 2Path No: 202 203 27.74 24.34 5.6 5.6 22.6 22.6 1 1.08 14.41 0 14.41 120 0.1413 16.3 1.5 2 203 138 24.34 23.29 5.6 25.1 47.7 1 1.08 1x(us.Tee-Br)=5.76 4.41 5.76 10.17 120 0.5626 20 0.5 5.7 138 26.3 3Path No: 205 206 27.74 24.34 5.6 5.6 23.2 23.2 1 1.08 14.41 0 14.41 120 0.1478 17.1 1.5 2.1 206 136 24.34 23.29 5.6 25.6 48.8 1 1.08 1x(us.Tee-Br)=5.76 4.41 5.76 10.17 120 0.5873 21 0.5 6 136 27.4 4Path No: 209 210 27.74 24.34 5.6 5.6 24.6 24.6 1 1.08 14.41 0 14.41 120 0.1649 19.3 1.5 2.4 210 134 24.34 23.29 5.6 27.1 51.6 1 1.08 1x(us.Tee-Br)=5.76 4.41 5.76 10.17 120 0.652 23.4 0.5 6.6 134 30.5 5Path No: 204 137 22.71 23.29 5.6 27.5 27.5 1 1.08 2x(us.Tee-Br)=11.52 2.62 11.52 14.14 120 0.203 24.1 -0.3 2.9 137 26.7 6Path No: 208 135 24.32 23.29 5.6 28.9 28.9 1 1.08 1x(us.Tee-Br)=5.76 4.41 5.76 10.17 120 0.2232 26.7 0.4 2.3 135 29.5 Date 11/5/2012 Page 23Copyright © 2002-2011 Tyco Fire Protection Products File: C:\dwg\phoenix = vail fire station\Vail Fire FP1.dwg Hydraulic CalculationsJob : Vail Fire Station #2 PIPE INFORMATION Node 1 Node 2 Elev 1 Elev 2 (ft) K-Factor 1 K-Factor 2 (gpm/psi½) Flow added (q) Total flow (Q) (gpm) Nominal ID Actual ID (in) Fittings quantity x (name) = length (ft) L F T (ft) C Factor Pf per ft (psi) total (Pt) elev (Pe) frict (Pf) (psi) NOTES 7Path No: 207 058 23.96 23.29 5.6 43.8 43.8 1 1.08 1x(us.Tee-Br)=5.76 1x(us.90)=2.3 1.66 8.07 9.72 120 0.481 61.2 0.3 4.7 058 056 23.29 23.29 0 43.8 2 2.203 1x(us.Tee-Br)=13.64 7.32 13.64 20.96 120 0.0149 66.2 0 0.3 056 66.6 * Pressures are balanced to a high degree of accuracy. Values may vary by 0.1 psi due to display rounding. * Maximum Velocity of 24.9 ft/s occurs in the following pipe(s): (019-056) Date 11/5/2012 Page 24Copyright © 2002-2011 Tyco Fire Protection Products File: C:\dwg\phoenix = vail fire station\Vail Fire FP1.dwg Device GraphsJob : Vail Fire Station #2 Pressure vs. Flow Function Design Area: 2; Supply Ref.: W1; Supply Name:W1 Flow, gpm 0 20 0 30 0 40 0 50 0 60 0 70 0 80 0 90 0 92 2 Pr e s s u r e , p s i 160 150 140 130 120 110 100 90 80 70 60 50 40 30 20 10 0 141.2 psi @ 395.9 gpm (295.9 gpm+100 gpm add. out. hose) Pressure Loss Function Design Area: 2; BFP Ref.: 274 (C400 DblChk Z, Size = 4) Flow, gpm 0 25 10 0 15 0 20 0 30 0 40 0 50 0 60 0 70 0 80 0 Pr e s s u r e , p s i 22.5 17.5 12.5 7.5 2.5 8 psi @ 295.9 gpm Date 11/5/2012 Page 25Copyright © 2002-2011 Tyco Fire Protection Products File: C:\dwg\phoenix = vail fire station\Vail Fire FP1.dwg Device GraphsJob : Vail Fire Station #2 Pressure Loss Function Design Area: 2; Valve Ref.: 273 (WILKINS PRV, Size = 4) Flow, gpm 0 20 0 30 0 40 0 50 0 60 0 70 0 10 0 0 Pr e s s u r e , p s i 22.5 17.5 12.5 7.5 2.5 2.2 psi @ 295.9 gpm Pressure Loss Function Design Area: 2; Valve Ref.: 275 (Riser Manifold, Size = 4) Flow, gpm 0 10 0 30 0 40 0 45 0 50 0 60 0 70 0 80 0 90 0 10 0 0 Pr e s s u r e , p s i 1.667 1.167 0.667 0.167 0.2 psi @ 295.9 gpm Date 11/5/2012 Page 26Copyright © 2002-2011 Tyco Fire Protection Products File: C:\dwg\phoenix = vail fire station\Vail Fire FP1.dwg General Description TheSeriesTY-FRB,5.6K-Factor,Hori- zontalandVerticalSidewallSprinklers describedinthisdatasheetarequick response-standardcoverage,deco- rative3mmglassbulbtypespray sprinklersdesignedforuseinlightand ordinaryhazard,commercialoccupan- ciessuchasbanks,hotels,shopping malls,etc.Theyaredesignedforinstal- lationalongawallorthesideofabeam andjustbeneathasmoothceiling. Sidewallsprinklersarecommonly usedinsteadofpendentorupright sprinklersduetoaestheticsorbuilding constructionconsiderations,where pipingacrosstheceilingisnotdesir- able. Therecessedversionof theSeries TY-FRBHorizontalSidewallSprinkler isintendedforuseinareaswitha finishedwall.Itusesatwo-piece Style 10RecessedEscutcheonwith1/2inch (12,7mm)ofrecessedadjustmentor upto3/4inch(19,1mm)oftotaladjust- mentfromtheflushsidewallposition, oratwo-pieceStyle20RecessedEs- cutcheon with1/4inch (6,4mm)of recessedadjustmentorupto1/2inch (12,7mm)oftotaladjustment fromthe flushsidewallposition.Theadjustment providedbytheRecessedEscutcheon reducestheaccuracytowhichthe fixedpipenipplestothesprinklers mustbecut. Corrosionresistant coatings,where applicable,areutilizedtoextendthe lifeofcopperalloysprinklersbeyond thatwhichwouldotherwisebeob- tainedwhenexposedtocorrosiveat- mospheres.Althoughcorrosionresis- tantcoatedsprinklershave passedthe standardcorrosiontestsoftheappli- cableapproval agencies,thetestingis notrepresentativeofallpossiblecor- rosiveatmospheres.Consequently,it isrecommendedthattheenduserbe consultedwithrespecttothesuitability ofthesecoatingsforanygivencorro- sive environment.Theeffectsof ambi- enttemperature,concentrationof chemicals,andgas/chemicalvelocity, shouldbeconsidered,asaminimum, alongwiththecorrosivenatureofthe chemicaltowhichthesprinklerswillbe exposed. WARNINGS TheSeriesTY-FRBSprinklersde- scribedhereinmustbeinstalledand maintainedincompliancewiththis document,aswellaswiththeapplica- ble standardsoftheNational FirePro- tectionAssociation,inadditiontothe standardsofanyotherauthoritieshav- ingjurisdiction.Failuretodosomay impair theperformanceofthesede- vices. Theownerisresponsibleformaintain- ingtheirfireprotectionsystemandde- vicesin properoperating condition. Theinstallingcontractororsprinkler manufacturershouldbecontacted withanyquestions. Model/Sprinkler Identification Numbers TY3331-Horizontal TY3431-Vertical Technical Data Approvals ULandC-ULListed. FM,LPCB,andNYCApproved. (RefertoTableAforcompleteapproval informationincludingcorrosionresis- tantstatus.) MaximumWorkingPressure 175psi(12,1bar) DischargeCoefficient K=5.6GPM/psi1/2 (80,6LPM/bar1/2) TemperatureRatings RefertoTableA Finishes Sprinkler:RefertoTableA RecessedEscutcheon:WhiteCoated, ChromePlated,orBrassPlated † D u P o n t R e g i s t e r e d T r a d e m a r k SeriesTY-FRB— 5.6 K-factor Horizontal andVertical SidewallSprinklers Quick Response,Standard Coverage Page1of6 TFP176JULY,2004 TechnicalServices:Tel:(800)381-9312/Fax:(800)791-5500 IMPORTANT AlwaysrefertoTechnicalData SheetTFP700forthe“INSTALLER WARNING”thatprovidescautions withrespecttohandlingandinstal- lationofsprinklersystemsandcom- ponents.Improperhandlingandin- stallationcanpermanentlydamage asprinklersystemoritscompo- nentsandcausethesprinklertofail tooperateinafiresituationorcause ittooperateprematurely. Customer Service/Sales: Tel:(414)570-5000 /(800)558-5236 Fax:(414)570-5010 /(800)877-1295 PhysicalCharacteristics Frame.............Bronze Button.........Brass/Copper SealingAssembly.......... .....BerylliumNickelw/Teflon† Bulb...............Glass CompressionScrew.....Bronze HSWDeflector........Bronze VSWDeflector........Copper Patents U.S.A.5,810,263 Operation TheglassBulbcontainsafluidwhich expandswhen exposed toheat.When theratedtemperatureisreached,the fluidexpandssufficientlytoshatterthe glassBulb,allowingthesprinklerto activateandwatertoflow. Page2of6 TFP176 TYPE TEMP.BULB LIQUID NATURAL BRASS CHROME PLATED WHITE*** POLYESTER 155°F/68°C 175°F/79°C 200°F/93°C SPRINKLERFINISH(See Note11) RECESSED HORIZ. SIDEWALL (TY3331)* Figure3 135°F/57°C Orange Red Yellow Green 1, 2,4,9, 10 NOTES: 1.ListedbyUnderwritersLaboratories,Inc.(UL)asQuickResponseSprinklersforuseinLightandOrdinaryHazardOccupanciesata 4to12inch(100to300mm)topofdeflectortoceilingdistance. 2.ListedbyUnderwritersLaboratoriesInc.foruseinCanada(C-UL)asQuickResponseSprinklersforuseinLightandOrdinary HazardOccupanciesata4to12inch(100to300mm)topofdeflectortoceilingdistance. 3.ApprovedbyFactoryMutualResearchCorporation(FM)asQuickResponseSprinklersforuseinLightHazardOccupanciesata 4to12inch(100to300mm)topofdeflectortoceilingdistance. 4.ApprovedbytheLossPreventionCertificationBoard(LPCBRef.No.007a/04)ata4to6inch(100to150mm)topof deflectortoceilingdistance.TheLPCdoesnotratethethermalsensitivityofhorizontalsidewallsprinklers. 5.ListedbyUnderwritersLaboratories,Inc.asQuickResponseSprinklersforuseinLightandOrdinaryHazardOccupancies. 6.ListedbyUnderwritersLaboratoriesforuseinCanada(C-UL)asQuickResponseSprinklersforuseinLightandOrdinaryHazard Occupancies. 7.ApprovedbyFactoryMutualResearchCorporation(FM)asQuickResponseSprinklersforuseinLightHazardOccupancies. 8.ApprovedbytheLossPreventionCertificationBoard(LPCBRef.No.094a/06&007a/04)asQuickResponseSprinklers. 9.ApprovedbytheCityofNewYorkunderMEA354-01-E. 10.ApprovedbytheLossPreventionCertificationBoard(LPCBRef.No.094a/06)ata4to6inch(100to150mm)topof deflectortoceilingdistance.TheLPCdoesnotratethethermalsensitivityofhorizontalsidewallsprinklers. 11.WherePolyesterCoatedandLeadCoatedSprinklersarenotedtobeULandC-ULListed,thesprinklersareULandC-ULListed asCorrosionResistantSprinklers.WhereLeadCoatedSprinklersarenotedtobeFMApproved,thesprinklersareFMApprovedas CorrosionResistantSprinklers. *InstalledwithStyle10(1/2"NPT)3/4"TotalAdjustmentRecessedEscutcheon. **InstalledwithStyle20(1/2"NPT)1/2"TotalAdjustmentRecessedEscutcheon. ***Frameanddeflectoronly.Listingsandapprovalsapplytocolor(SpecialOrder). TABLEA LABORATORYLISTINGSANDAPPROVALS LEAD COATED N/A 1,2, 3,9 K 5.6 1/2" NPT HORIZ. SIDEWALL (TY3331) 135°F/57°C Orange 155°F/68°C Red 175°F/79°C Yellow 200°F/93°C Green 286°F/141°C Blue 1,2,3, 4,9,10 5.6 1/2" NPT VERTICAL SIDEWALL (TY3431) Installed Pendent or Upright 135°F/57°C 155°F/68°C 175°F/79°C 200°F/93°C 286°F/141°C Blue Green Yellow Red Orange 5, 6,7,8, 9 5,6, 7,9 Orange Red Yellow Green RECESSED HORIZ. SIDEWALL (TY3331)** Figure4 135°F/57°C 155°F/68°C 175°F/79°C 200°F/93°C 1, 2,3,4, 9 N/A 1,2, 3,9 1,2,9 Design Criteria TheSeriesTY-FRBHorizontaland VerticalSidewallSprinklersarein- tendedforfireprotectionsystemsde- signedinaccordancewiththestand- ardinstallationrulesrecognizedbythe applicableListingorApprovalagency (e.g.,ULListingisbasedonthere- quirementsofNFPA13,andFMAp- provalisbasedontherequirementsof FM’sLossPreventionDataSheets). OnlytheStyle10or20RecessedEs- cutcheon,asapplicable,istobeused forrecessedhorizontalinstallations. Installation TheSeriesTY-FRBSprinklersmustbe installedinaccordancewiththefollow- inginstructions: NOTES Do notinstallany bulb type sprinklerif thebulbiscrackedorthereisalossof liquidfromthebulb.Withthesprinkler heldhorizontally,asmallairbubble shouldbepresent.Thediameterofthe airbubbleisapproximately1/16inch (1,6mm)forthe135°F/57°Cto3/32 inch(2,4mm)forthe286°F/141°C temperatureratings. Aleaktight1/2inchNPTsprinklerjoint shouldbeobtainedwithatorqueof7 to14ft.lbs.(9,5to19,0Nm).Amaxi- mumof21ft.lbs.(28,5Nm)oftorque maybeusedtoinstallsprinklerswith 1/2NPTconnections.Higherlevelsof torquemaydistortthesprinklerand causeleakageorimpairmentofthe sprinkler. Donotattempttomake-upforinsuffi- cientadjustmentintheescutcheon platebyunder-orover-tighteningthe sprinkler.Readjustthepositionofthe sprinklerfittingtosuit. The SeriesTY-FRBHorizontaland VerticalSidewall Sprinklers mustbe installedinaccordancewiththefollow- inginstructions. Step1.Horizontalsidewallsprinklers are to beinstalledinthe horizontal positionwiththeircenterlineofwater- wayperpendiculartothebackwalland paralleltotheceiling.Theword“TOP” ontheDeflectoristofacetowardsthe ceiling. Verticalsidewallsprinklersaretobe installedinthependentoruprightpo- sitionwiththearrowontheDeflector pointingawayfromthewall. Step2.Withpipethreadsealantap- pliedtothepipethreads,handtighten thesprinklerintothesprinklerfitting. Step3.Tightenthesprinklerintothe sprinklerfittingusingonlytheW-Type 6SprinklerWrench (Ref.Figure5), WithreferencetoFigure1or2,the W-Type6SprinklerWrenchistobe appliedtothewrenchflats. The SeriesTY-FRBRecessedHori- zontalSidewallSprinklers mustbe installedinaccordancewiththefollow- inginstructions. StepA.Recessedhorizontalsidewall sprinklersare tobe installed in the horizontalpositionwiththeircenterline ofwaterwayperpendiculartotheback wall andparallel to theceiling.The word“TOP” ontheDeflectoristoface towardstheceiling. StepB.AfterinstallingtheStyle10or 20MountingPlateoverthesprinkler threads,handtightenthesprinklerinto thesprinklerfitting. StepC.Tightenthesprinklerintothe sprinklerfittingusingonlytheW-Type 7 RecessedSprinklerWrench (Ref. Figure6).WithreferencetoFigure1, theW-Type7RecessedSprinkler Wrenchistobeappliedtothesprinkler wrenchflats. StepD.Aftertheceilinghasbeenin- stalledorthefinishcoathasbeenap- TFP176 Page3of6 FIGURE1 5.6K-FACTORQUICKRESPONSE SERIESTY-FRBHORIZONTALSIDEWALL(TY3331)SPRINKLERS 1-Frame 2-Button 3-Sealing Assembly 4-Bulb 5-Compression Screw 6-Deflector *Temperatureratingisindicatedondeflectororadjacenttoorificeseatonframe. **PipethreadconnectionsperISO7/1canbeprovidedonspecialrequest. 24 5 PLATESEATING ESCUTCHEON (11,1 mm) NOMINAL MAKE-IN SURFACE 13 2-7/8" DIA. ESCUTCHEON 10or 20 RECESSED (73,0mm) WRENCH FLATS 1-1/2" (38,1mm) 2-3/16" (55,6mm) 7/16"1-13/16" (46,0mm) STYLE HAT DEFLECTOR 1/2" NPT 6 CENTERLINE WATERWAY OFSPRINKLER 9/16" (14,3mm) * ** plied,slideontheStyle10or20Clo- sureover theSeriesTY-FRBSprinkler andpushtheClosure overtheMount- ingPlateuntilitsflangecomesincon- tactwiththeceiling Care and Maintenance TheSeriesTY-BFRSprinklersmustbe maintainedand servicedinaccord- ancewiththefollowinginstructions: NOTES Beforeclosingafireprotectionsystem maincontrolvalveformaintenance workonthefireprotectionsystemthat itcontrols,permissiontoshutdownthe affectedfireprotectionsystemmustbe obtainedfromtheproperauthorities andallpersonnelwhomaybeaffected bythisactionmustbenotified. Absenceofanescutcheon,whichis usedtocoveraclearancehole,may delaythe timetosprinkleroperationin afiresituation. Sprinklersthat are found tobe leaking orexhibitingvisiblesignsofcorrosion mustbereplaced. Automaticsprinklersmust neverbe painted,plated,coatedorotherwise alteredafterleavingthefactory.Modi- fiedsprinklersmustbereplaced. Sprinklersthathavebeenexposedto corrosiveproductsofcombustion,but havenotoperated,shouldbereplaced iftheycannotbecompletelycleaned bywipingthesprinklerwithaclothor bybrushingitwithasoftbristlebrush. Caremustbeexercisedtoavoiddam- agetothesprinklers-before,during, andafterinstallation.Sprinklersdam- agedbydropping,striking,wrench twist/slippage,orthelike,mustbere- placed.Also,replaceanysprinklerthat hasacrackedbulborthathaslost liquidfromitsbulb.(Ref.Installation Section). Frequent visualinspectionsarerec- ommendedtobeinitiallyperformedfor corrosionresistantcoatedsprinklers, after the installationhas beencom- pleted,toverifytheintegrityofthecor- rosionresistantcoating.Thereafter, annualinspectionsperNFPA25 shouldsuffice;however,insteadofin- specting fromthefloorlevel,arandom samplingofclose-upvisualinspec- tionsshouldbemade,soastobetter determinetheexactsprinklercondi- tionandthelongtermintegrityofthe corrosionresistantcoating,asitmay beaffectedbythecorrosiveconditions present. Theownerisresponsibleforthein- spection,testing,andmaintenanceof theirfireprotectionsystemandde- vicesin compliancewiththis docu- ment,aswellaswiththeapplicable standardsoftheNationalFireProtec- tionAssociation(e.g.,NFPA25),in additiontothestandardsofanyother authoritieshavingjurisdiction.Thein- stallingcontractororsprinklermanu- facturershouldbecontactedrelativeto anyquestions. Itisrecommendedthatautomatic sprinklersystemsbeinspected, tested,andmaintainedbyaqualified InspectionServiceinaccordancewith localrequirementsand/ornational codes. Limited Warranty ProductsmanufacturedbyTycoFire Productsarewarrantedsolelytothe originalBuyerforten(10)years againstdefectsinmaterialandwork- manshipwhenpaidforandproperly installedandmaintainedundernormal useandservice.Thiswarrantywillex- pireten(10)yearsfromdateofship- mentbyTycoFireProducts.Nowar- rantyisgivenforproductsorcompo- nents manufacturedbycompaniesnot affiliatedbyownershipwithTycoFire Productsorforproductsandcompo- nentswhichhave beensubjecttomis- use,improperinstallation,corrosion, orwhichhavenotbeeninstalled,main- tained,modifiedorrepairedinaccord- ancewithapplicableStandardsofthe NationalFireProtectionAssociation, and/orthestandardsofanyother AuthoritiesHavingJurisdiction.Mate- rialsfoundbyTycoFireProductstobe defectiveshallbeeitherrepairedor replaced,atTycoFireProducts’sole option.TycoFireProductsneitheras- sumes,norauthorizesanypersonto assumeforit,anyotherobligationin connectionwiththesaleofproductsor partsofproducts.TycoFireProducts shallnotberesponsibleforsprinkler systemdesignerrorsorinaccurateor incompleteinformationsuppliedby BuyerorBuyer’srepresentatives. INNOEVENTSHALLTYCOFIRE PRODUCTSBELIABLE,INCON- TRACT,TORT,STRICTLIABILITYOR UNDERANYOTHERLEGALTHE- ORY,FORINCIDENTAL,INDIRECT, SPECIALORCONSEQUENTIAL Page4of6 TFP176 FIGURE2 5.6K-FACTORQUICKRESPONSE SERIESTY-FRBVERTICALSIDEWALL(TY3431)SPRINKLERS 1-Frame 2-Button 3-Sealing Assembly 4-Bulb 5-Compression Screw 6-Deflector 7-EjectionSpring *Temperatureratingisindicatedondeflectororadjacenttoorificeseatonframe. **PipethreadconnectionsperISO7/1canbeprovidedonspecialrequest. PLATESEATING ESCUTCHEON WRENCH FLATS (11,1 mm) NOMINAL MAKE-INSURFACENPT 1/2" SECTIONPENDENTUPRIGHT CROSS 3 1 2 5 4 6* 7 (55,6mm) 2-3/16" (38,1mm) 1-1/2" SHOWNSHOWN ** FROMANDBE PERPENDICULAR POINTAWAY TOTHE BACK WALLSURFACE ARROWMUST 7/16" 2-3/16" (55,6mm) DAMAGES,INCLUDINGBUTNOT LIMITEDTOLABORCHARGES,RE- GARDLESSOFWHETHERTYCO FIREPRODUCTSWASINFORMED ABOUTTHEPOSSIBILITYOFSUCH DAMAGES,ANDINNOEVENT SHALLTYCOFIREPRODUCTS’LI- ABILITYEXCEED AN AMOUNT EQUALTOTHESALESPRICE. THEFOREGOINGWARRANTYIS MADEINLIEUOFANYANDALL OTHERWARRANTIESEXPRESSOR IMPLIED,INCLUDINGWARRANTIES OFMERCHANTABILITYANDFIT- NESSFORAPARTICULARPUR- POSE. TFP176 Page5of6 FIGURE3 SERIESTY-FRBRECESSEDHORIZONTALSIDEWALLSPRINKLER WITHTWO-PIECE3/4INCHTOTALADJUSTMENT STYLE10RECESSEDESCUTCHEON FIGURE5 W-TYPE6SPRINKLERWRENCH WRENCH RECESS (END"A"USEDFOR 1/2"NPT MODELS) FIGURE6 W-TYPE7RECESSED SPRINKLERWRENCH RECESS WRENCH WITHSPRINKLER ENGAGEMENT IN TOENSURE WRENCHING AREA PUSHWRENCH MOUNTING 3/4"(19,1mm) 1-1/4"(31,8 mm) PLATE CLOSURE SURFACE MOUNTING (73,0 mm) 2-1/4"DIA. (57,2 mm) 1/4"(6,4 mm) 3/4"(19,1mm) (3,2mm) 1/8" 5/8±1/4" FACEOF FITTING SPRINKLER (15,9±6,4mm) 2-7/8"DIA. SERIES TY-FRB FIGURE4 SERIESTY-FRBRECESSEDHORIZONTALSIDEWALLSPRINKLER WITHTWO-PIECE1/2INCHTOTALADJUSTMENT STYLE20RECESSEDESCUTCHEON MOUNTING 1"(25,4mm) 1-1/4"(31,8 mm) PLATE CLOSURE SURFACE MOUNTING (73,0 mm) 2-1/4"DIA. (57,2 mm) 1/4"(6,4 mm) 1/2"(12,7mm) (3,2mm) 1/8" 1/2±1/8" FACEOF FITTING SPRINKLER (12,7±3,2mm) 2-7/8"DIA. SERIES TY-FRB Ordering Procedure Whenplacinganorder,indicatethefull productname.RefertothePriceList forcompletelistingofPartNumbers. Contactyourlocaldistributorforavail- ability. SprinklerAssemblieswithNPT ThreadConnections: Specify:(SpecifyModel/SIN),Quick Response,(specifyK-factor),(specify temperaturerating),SeriesTY-FRB (specifyHorizontalSidewallorVertical Sidewall)Sprinklerwith(specifytype offinishorcoating),P/N(specifyfrom TableB). RecessedEscutcheon: Specify:Style(specify)RecessedEs- cutcheonwith(specifyfinish),P/N (specify). 1/2"(15mm) Style10 ChromePlated. ... ... ..P/N56-701-9-010 1/2"(15mm) Style10 WhiteColor Coated. ... ... ... ... ..P/N56-701-4-010 1/2"(15mm) Style10 WhiteRAL9010*.. ... ..P/N56-701-3-010 1/2"(15mm) Style10 BrassPlated... ... ... ..P/N56-701-2-010 1/2"(15mm) Style20 ChromePlated. ... ... ..P/N56-705-9-010 1/2"(15mm) Style20 WhiteColor Coated. ... ... ... ... ..P/N56-705-4-010 1/2"(15mm) Style20 WhiteRAL9010*.. ... ..P/N56-705-3-010 1/2"(15mm) Style20 BrassPlated... ... ... ..P/N56-705-2-010 *EasternHemispheresalesonly. SprinklerWrench: Specify:W-Type6SprinklerWrench, P/N56-000-6-387. Specify:W-Type7SprinklerWrench, P/N56-850-4-001. Page6of6 TFP176 TYCOFIREPRODUCTS,451NorthCannon Avenue,Lansdale,Pennsylvania19446 P/N57—XXX—X—XXX 155°F/68°C155 TEMPERATURE RATING 135°F/57°C1351 SPRINKLER TABLEB PARTNUMBERSELECTION SERIESTY-FRBHORIZONTALANDVERTICALSIDEWALLSPRINKLERS 175°F/79°C 286 200°F/93°C200 286°F/141°C 175 WHITEPOLYESTER NATURAL BRASS 9 4 MODEL/SIN CHROME PLATED 7 LEAD COATED 378 HORIZONTALSIDEWALL 375 VERTICALSIDEWALL TY3331 TY3431 3 WHITE RAL9010)* *EasternHemispheresalesonly. Series TY-FRB — 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage Page 1 of 10 JULY 2010 TFP171 IMPORTANT Always refer to Technical Data Sheet TFP700 for the “INSTALLER WARNING” that provides cautions with respect to handling and installation of sprinkler systems and components. Improper handling and installation can permanently damage a sprinkler system or its components and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Technical Services 800-381-9312 | +1-401-781-8220 www.tyco-fire.com General Description The TYCO Series TY-FRB, 2.8, 4.2, 5.6, and 8.0 K-factor, Upright and Pendent Sprinklers described in this data sheet are quick response, standard coverage, decorative 3 mm glass bulb-type spray sprinklers designed for use in light or ordinary hazard, commercial occupan- cies such as banks, hotels, and shop- ping malls. The recessed version of the Series TY- FRB Pendent Sprinkler, where applica- ble, is intended for use in areas with a finished ceiling. This recessed pendent sprinkler uses one of the following, • A two-piece Style 10 (1/2 inch NPT) or Style 40 (3/4 inch NPT) Recessed Escutcheon with 1/2 inch (12,7 mm) of recessed adjustment or up to 3/4 inch (19,1 mm) of total adjustment from the flush pendent position, or a • A two-piece Style 20 (1/2 inch NPT) or Style 30 (3/4 inch NPT) Recessed Escutcheon with 1/4 inch (6,4 mm) of recessed adjustment or up to 1/2 inch (12,7 mm) of total adjustment from the flush pendent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Corrosion-resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be obtained when exposed to corrosive atmo- spheres. Although corrosion-resistant coated sprinklers have passed the standard corrosion tests of the appli- cable approval agencies, the testing is not representative of all possible cor- rosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suit- ability of these coatings for any given corrosive environment. The effects of ambient temperature, concentration of chemicals, and gas/chemical velocity, should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. An intermediate level of the Series TY- FRB Pendent Sprinklers is detailed in Technical Data Sheet TFP356, and Sprinkler Guards are detailed in Tech- nical Data Sheet TFP780. NOTICE The Series TY-FRB Concealed Pendent Sprinklers described herein must be installed and maintained in compliance with this document and with the appli- cable standards of the National Fire Protection Association, in addition to the standards of any authorities having jurisdiction. Failure to do so may impair the performance of these devices. Owners are responsible for maintaining their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manu- facturer should be contacted with any questions. Model/Sprinkler Identification Number (SIN) TY1131: Upright 2.8K, 1/2 ˝ NPT TY1231: Pendent 2.8K, 1/2 ˝ NPT TY2131: Upright 4.2K, 1/2 ˝ NPT TY2231: Pendent 4.2K, 1/2 ˝ NPT TY3131: Upright 5.6K, 1/2 ˝ NPT TY3231: Pendent 5.6K, 1/2 ˝ NPT TY4131: Upright 8.0K, 3/4˝ NPT TY4231: Pendent 8.0K, 3/4˝ NPT TY4831: Upright* 8.0K, 1/2 ˝ NPT TY4931: Pendent* 8.0K, 1/2 ˝ NPT *Eastern Hemisphere Sales Only TFP171 Page 2 of 10 WRENCH (38,1 mm)(55,6 mm) 2-7/8" (73,0 mm) DIA. 1 3 1/2" NPT SSP DEFLECTOR FLATS STYLE 10 or 20 RECESSED ESCUTCHEON 7/16" (11,1 mm) 5 4 2 6 7/16" MAKE-IN NOMINAL (11,1 mm) 2-3/16" DEFLECTOR SSU ESCUTCHEON PLATE SEATING (55,6 mm) SURFACE 1-1/2" 1/2" NPT NOMINAL MAKE-IN 2-3/16" RECESSED PENDENTCROSS SECTION UPRIGHT PENDENT * * * FIGURE 1 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY1131) AND PENDENT (TY1231) SPRINKLERS 2.8 K-FACTOR, 1/2 INCH NPT FIGURE 2 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY2131) AND PENDENT (TY2231) SPRINKLERS 4.2 K-FACTOR, 1/2 INCH NPT PENDENTCROSS SECTION UPRIGHT RECESSED PENDENT SSP DEFLECTOR 2-1/4" (57,2 mm) (39,7 mm) 1-9/16" PLATE SEATING SURFACE ESCUTCHEON 1/2" NPT WRENCH FLATS MAKE-IN NOMINAL 7/16" (11,1 mm) MAKE-IN NOMINAL (11,1 mm) 7/16" 2-3/16" (55,6 mm) SSU DEFLECTOR 2 7 1 3 5 4 6 2-7/8" (73,0 mm) DIA. RECESSED STYLE 10 or 20 ESCUTCHEON 1/2" NPT * * * 1 - Frame 3 - Sealing Assembly 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to orifice seat on frame.2 - Button 5 - Compression Screw 7 - Bushing 1 - Frame 3 - Sealing Assembly 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to orifice seat on frame.2 - Button 5 - Compression Screw TFP171 Page 3 of 10 SSP DEFLECTOR WRENCH(55,6 mm) 1 3 1/2" NPT FLATS 5 4 2 6 7/16" (11,1 mm) SSU DEFLECTOR 7/16" 2-3/16" NOMINAL MAKE-IN (11,1 mm) NOMINAL MAKE-IN 1/2" NPT (38,1 mm) 2-7/8" (73,0 mm) DIA. STYLE 10 or 20ESCUTCHEON 2-3/16" (55,6 mm) 1-1/2" PLATE SEATING SURFACE RECESSED ESCUTCHEON PENDENTCROSS SECTION UPRIGHT RECESSED PENDENT * * * (39,7 mm)(57,2 mm) 1 3 3/4" NPT SSP DEFLECTOR 2-7/8" (73,0 mm) DIA. (12,7 mm) MAKE-IN NOMINAL 5 4 2 2-1/4" 6 ESCUTCHEON1/2" (12,7 mm) 1/2" DEFLECTOR SSU NOMINAL MAKE-IN 1-9/16" 2-5/16" (58,7 mm) PLATE SEATING SURFACE3/4" NPT STYLE 30 or 40 RECESSED ESCUTCHEON CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT * * * FIGURE 3 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY3131) AND PENDENT (TY3231) SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT FIGURE 4 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY4131) AND PENDENT (TY4231) SPRINKLERS 8.0 K-FACTOR, 3/4 INCH NPT 1 - Frame 3 - Sealing Assembly 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to orifice seat on frame.2 - Button 5 - Compression Screw 1 - Frame 3 - Sealing Assembly 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to orifice seat on frame.2 - Button 5 - Compression Screw TFP171 Page 4 of 10 † Registered Trademark of Dupont Technical Data Approvals UL and C-UL Listed FM, LPCB, and NYC Approved Refer to Table A and B for complete approval information including corrosion-resistant status. Maximum Working Pressure Refer to Table C. Discharge Coefficient K=2.8 GPM/psi1/2 (40,3 LPM/bar1/2) K=4.2 GPM/psi1/2 (60,5 LPM/bar1/2) K=5.6 GPM/psi1/2 (80,6 LPM/bar1/2) K=8.0 GPM/psi1/2 (115,2 LPM/bar1/2) Temperature Rating Refer to Table A and B. Finishes Sprinkler: Refer to Table A and B. Recessed Escutcheon: White Coated, Chrome Plated, or Brass Plated. Physical CharacteristicsFrame...................Bronze Button..............Brass/Copper Sealing Assembly .........Beryllium Nickel w/Teflon† Bulb ......................Glass Compression Screw ........Bronze Deflector ...........Copper/Bronze Bushing (K=2.8) ...........Bronze (39,7 mm)WRENCH(55,6 mm)3 1 DEFLECTOR1/2" NPT SSP FLATS DEFLECTOR (11,1 mm) NOMINAL 2 4 5 6 MAKE-IN 2-3/16" 7/16" 7/16" (11,1 mm) 1/2" NPT NOMINAL MAKE-IN SSU 2-1/4" (57,2 mm) 1-9/16" SECTION CROSS PENDENTUPRIGHT * * * FIGURE 5 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY4831) AND PENDENT (TY4931) SPRINKLERS 8.0 K-FACTOR, 1/2 INCH NPT Operation The glass Bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass Bulb, allowing the sprinkler to activate and water to flow. Design Criteria The TYCO Series TY-FRB Pendent and Upright Sprinklers are intended for fire protection systems designed in accordance with the standard installa- tion rules recognized by the applicable Listing or Approval agency (such as, UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM’s Loss Preven- tion Data Sheets). Only the Style 10, 20, 30, or 40 Recessed Escutcheon, as applicable, is to be used for recessed pendent installations. Installation The TYCO Series TY-FRB Sprinklers must be installed in accordance with the following instructions. NOTICE Do not install any bulb-type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bub- ble should be present. The diameter of the air bubble is approximately 1/16 1 - Frame 3 - Sealing Assembly 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to orifice seat on frame.2 - Button 5 - Compression Screw inch (1,6 mm) for the 135°F/57°C and 3/32 inch (2,4 mm) for the 286°F/141°C temperature ratings. Obtain a leak-tight 1/2 inch NPT sprin- kler joint by applying a minimum to maximum torque of 7 to 14 ft.lbs. (9,5 to 19,0 Nm). Higher levels of torque can distort the sprinkler Inlet with con- sequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in the Escutch- eon Plate by under- or over-tightening the sprinkler. Re-adjust the position of the sprinkler fitting to suit. The Series TY-FRB Pendent and Upright Sprinklers must be installed in accordance with the following instructions. 1. Install Pendent sprinklers in the pendent position. Install upright sprinklers in the upright position. 2. With pipe-thread sealant applied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. 3. Tighten the sprinkler into the sprin- kler fitting using only the W-Type 6 Sprinkler Wrench (Figure 14). With reference to Figures 1 through 5, apply the W-Type 6 Sprinkler Wrench to the sprinkler wrench flats. TFP171 Page 5 of 10 SPRINKLER FINISH (See Note 5) K FACTOR TYPE TEMPERATURE BULB LIQUID COLOR NATURAL BRASS CHROME PLATED WHITE*** POLYESTER 2.8 1/2” NPT PENDENT (TY1231) and UPRIGHT (TY1131) 135°F/57°C Orange 1, 2, 3, 4 155°F/68°C Red 175°F/79°C Yellow 200°F/93°C Green 286°F/141°C Blue RECESSED PENDENT (TY1231)* Figure 6 135°F/57°C Orange 1, 2, 4 155°F/68°C Red 175°F/79°C Yellow 200°F/93°C Green RECESSED PENDENT (TY1231)** Figure 7 135°F/57°C Orange 155°F/68°C Red 175°F/79°C Yellow 200°F/93°C Green 4.2 1/2” NPT PENDENT (TY2231) and UPRIGHT (TY2131) 135°F/57°C Orange 1, 2 155°F/68°C Red 175°F/79°C Yellow 200°F/93°C Green 286°F/141°C Blue RECESSED PENDENT (TY2231)* Figure 8 135°F/57°C Orange 155°F/68°C Red 175°F/79°C Yellow 200°F/93°C Green RECESSED PENDENT (TY2231)** Figure 9 135°F/57°C Orange 155°F/68°C Red 175°F/79°C Yellow 200°F/93°C Green NOTES: 1. Listed by Underwriters Laboratories, Inc., (UL) as Quick Response Sprinklers. 2. Listed by Underwriters Laboratories, Inc., for use in Canada (C-UL) as Quick Response Sprinklers. 3. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. 4. Approved by the City of New York under MEA 354-01-E. 5. Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion-Resistant Sprinklers. * Installed with Style 10 (1/2” NPT) or Style 40 (3/4” NPT) 3/4” Total Adjustment Recessed Escutcheon, as applicable. ** Installed with Style 20 (1/2” NPT) or Style 30 (3/4” NPT) 1/2” Total Adjustment Recessed Escutcheon, as applicable. *** Frame and Deflector only. Listings and approvals apply to color (Special Order). N/A: Not Available TABLE A LABORATORY LISTINGS AND APPROVALS FOR 2.8 AND 4.2 K-FACTOR SPRINKLERS TFP171 Page 6 of 10 SPRINKLER FINISH (See Note 8) K FACTOR TYPE TEMPERATURE BULB LIQUID COLOR NATURAL BRASS CHROME PLATED WHITE*** POLYESTER LEAD COATED 5.6 1/2” NPT PENDENT (TY3231) and UPRIGHT (TY3131) 135°F/57°C Orange 1, 2, 3, 4, 5, 6, 7 1, 2, 3, 5 155°F/68°C Red 175°F/79°C Yellow 200°F/93°C Green 286°F/141°C Blue RECESSED PENDENT (TY3231)* Figure 10 135°F/57°C Orange 1, 2, 4, 5 N/A 155°F/68°C Red 175°F/79°C Yellow 200°F/93°C Green 286°F/141°C Blue RECESSED PENDENT (TY3231)** Figure 11 135°F/57°C Orange 1, 2, 3, 4, 5 N/A 155°F/68°C Red 175°F/79°C Yellow 200°F/93°C Green 286°F/141°C Blue 8.0 3/4” NPT PENDENT (TY4231) and UPRIGHT (TY4131) 135°F/57°C Orange 1, 2, 3, 4, 5, 6, 7 1, 2, 5 155°F/68°C Red 175°F/79°C Yellow 200°F/93°C Green 286°F/141°C Blue RECESSED PENDENT (TY4231)* Figure 12 135°F/57°C Orange 1, 2, 5 N/A 155°F/68°C Red 175°F/79°C Yellow 200°F/93°C Green 286°F/141°C Blue RECESSED PENDENT (TY4231)** Figure 13 135°F/57°C Orange 1, 2, 3, 5 N/A 155°F/68°C Red 175°F/79°C Yellow 200°F/93°C Green 286°F/141°C Blue 8.0 1/2” NPT PENDENT (TY4931) and UPRIGHT (TY4831) 135°F/57°C Orange 1, 2, 4, 5, 6 1, 2, 5 155°F/68°C Red 175°F/79°C Yellow 200°F/93°C Green 286°F/141°C Blue NOTES: 1. Listed by Underwriters Laboratories, Inc., (UL) as Quick Response Sprinklers. 2. Listed by Underwriters Laboratories, Inc., for use in Canada (C-UL) as Quick Response Sprinklers. 3. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. 4. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007k/04) as Quick Response Sprinklers. However, LPCB does not rate the thermal sensitivity of recessed sprinklers. 5. Approved by the City of New York under MEA 354-01-E. 6. VdS Approved (For details, contact Tyco Fire Suppression & Building Products, Enschede, Netherlands, Tel. 31-53-428-4444/Fax 31-53-428-3377.) 7. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/06) as Quick Response Sprinklers. 8. Where Polyester Coated and Lead-Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion-Resistant Sprinklers. Where Lead-Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as a Corrosion-Resistant Sprinklers. * Installed with Style 10 (1/2” NPT) or Style 40 (3/4” NPT) 3/4” Total Adjustment Recessed Escutcheon, as applicable. ** Installed with Style 20 (1/2” NPT) or Style 30 (3/4” NPT) 1/2” Total Adjustment Recessed Escutcheon, as applicable. *** Frame and Deflector only. Listings and approvals apply to color (Special Order). N/A: Not Available TABLE B LABORATORY LISTINGS AND APPROVALS FOR 5.6 AND 8.0 K-FACTOR SPRINKLERS TFP171 Page 7 of 10 The Series TY-FRB Recessed Pendent Sprinklers must be installed in accor- dance with the following instructions. 1. After installing the Style 10, 20, 30, or 40 Mounting Plate, as applica- ble, over the sprinkler threads and with pipe-thread sealant applied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. 2. Tighten the sprinkler into the sprin- kler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Fig- ure 15). With reference to Figures 1 to 4, apply the W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. 3. After ceiling installation and finish- ing, slide on the Style 10, 20, 30, or 40 Closure over the Series TY-FRB Sprinkler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. Care and Maintenance The TYCO Series TY-FRB must be maintained and serviced in accordance with the following instructions. NOTICE Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection systems from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, can delay sprinkler operation in a fire situation. Exercise care to avoid damage to sprinklers before, during, and after installation. Never paint, plate, coat, or otherwise alter automatic sprinklers after they leave the factory. Replace sprinklers that: • were modified or over-heated. • were damaged by dropping, striking, wrench twisting, wrench slippage, or the like. • are leaking or exhibiting visible signs of corrosion. • were exposed to corrosive products of combustion but have not oper- ated, if you cannot easily remove combustion by-products with a cloth. • have a cracked bulb or have lost liq- uid from the bulb. Refer to the Instal- lation section in this data sheet. SPRINKLER FINISH K FACTOR TYPE NATURAL BRASS CHROME PLATED WHITE POLYESTER LEAD COATED 2.8 1/2” NPT PENDENT (TY1231) and UPRIGHT (TY1131)75 PSI (12,1 BAR)N/A RECESSED PENDENT (TY1231) 4.2 1/2” NPT PENDENT (TY2231) and UPRIGHT (TY2131)175 PSI (12,1 BAR) N/A RECESSED PENDENT (TY2231) 5.6 1/2” NPT PENDENT (TY3231) and UPRIGHT (TY3131) 250 PSI (17,2 BAR) OR 175 PSI (12,1 BAR) (SEE NOTE 1) 175 PSI (12,1 BAR) RECESSED PENDENT (TY3231)N/A 8.0 3/4” NPT PENDENT (TY4231) and UPRIGHT (TY4131)175 PSI (12,1 BAR) 175 PSI (12,1 BAR) RECESSED PENDENT (TY4231)N/A 8.0 1/2” NPT PENDENT (TY4931) and UPRIGHT (TY4831)175 PSI (12,1 BAR)175 PSI (12,1 BAR) NOTES: 1. The maximum working pressure of 250 psi (17,2 bar) only applies to the Listing by Underwriters Laboratories Inc. (UL); the Listing by Underwriters Laboratories, Inc. for use in Canada (C-UL); and, the Approval by the City of New York. TABLE C MAXIMUM WORKING PRESSURE TFP171 Page 8 of 10 Initial and frequent visual inspections of random samples are recommended for corrosion-resistant sprinklers to verify the integrity of the corrosion-resistant material of construction. Thereafter, annual inspections per NFPA 25 should suffice. Inspections of corrosion-resistant sprinklers are recommended at close range, instead of from the floor level per NFPA. Inspection at close range can better determine the exact sprin- kler condition and the long-term integ- rity of the corrosion-resistant material, which can be affected by the corrosive conditions present. Responsibility lies with the owner for the inspection, testing, and mainte- nance of their fire protection system and devices in compliance with this document, as well as with the appli- cable standards of the National Fire Protection Association (for example, NFPA 25), in addition to the standards of any other authorities having jurisdic- tion. Contact the installing contractor or sprinkler manufacturer regarding any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. Care must be exercised to avoid dam- age to the sprinklers -before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section). Initial and frequent visual inspections of random samples are recommended for corrosion-resistant sprinklers to verify the integrity of the corrosion-resistant material of construction. Thereafter, annual inspections per NFPA 25 should suffice. FIGURE 6 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 2.8 K-FACTOR, 1/2 INCH NPT (57,2 mm) 2-1/4" DIA. (73,0 mm) 2-7/8" DIA. SPRINKLER MOUNTING CLOSURE SERIES SURFACE FACE OF FITTING (15,9±6,4 mm) 5/8±1/4" (3,2 mm) 13/16" (20,6 mm) 1-5/16" (33,3 mm) PLATE MOUNTING 1/8" 1/4" (6,4 mm) 3/4" (19,1 mm) TY-FRB (12,7±3,2 mm) 1/2±1/8" 2-1/4" DIA. (57,2 mm) (73,0 mm) 2-7/8" DIA. SPRINKLER MOUNTING CLOSURE SURFACE FACE OF FITTING (3,2 mm) 1-1/16" (27,0 mm) 1-5/16" (33,3 mm) PLATE MOUNTING 1/8" 1/4" (6,4 mm) 1/2" (12,7 mm) TY-FRB SERIES FIGURE 7 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 2.8 K-FACTOR, 1/2 INCH NPT (57,2 mm) 2-1/4" DIA. (73,0 mm) 2-7/8" DIA. SPRINKLER MOUNTING CLOSURE SERIES SURFACE FACE OF FITTING (15,9±6,4 mm) 5/8±1/4" (3,2 mm) 3/4" (19,1 mm) 1-1/4" (31,8 mm) PLATE MOUNTING 1/8" 1/4" (6,4 mm) 3/4" (19,1 mm) TY-FRB FIGURE 8 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 4.2 K-FACTOR, 1/2 INCH NPT (12,7±3,2 mm) 1/2±1/8" 2-1/4" DIA. (57,2 mm) (73,0 mm) 2-7/8" DIA. SPRINKLER MOUNTING CLOSURE SURFACE FACE OF FITTING (3,2 mm) 1" (25,4 mm) 1-1/4" (31,8 mm) PLATE MOUNTING 1/8" 1/4" (6,4 mm) 1/2" (12,7 mm) TY-FRB SERIES FIGURE 9 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 4.2 K-FACTOR, 1/2 INCH NPT TFP171 Page 9 of 10 FIGURE 10 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT (57,2 mm) 2-1/4" DIA. (73,0 mm) 2-7/8" DIA. SPRINKLER MOUNTING CLOSURE SERIES SURFACE FACE OF FITTING (15,9±6,4 mm) 5/8±1/4" (3,2 mm) 3/4" (19,1 mm) 1-1/4" (31,8 mm) PLATE MOUNTING 1/8" 1/4" (6,4 mm) 3/4" (19,1 mm) TY-FRB (12,7±3,2 mm) 1/2±1/8" 2-1/4" DIA. (57,2 mm) (73,0 mm) 2-7/8" DIA. SPRINKLER MOUNTING CLOSURE SURFACE FACE OF FITTING (3,2 mm) 1" (25,4 mm) 1-1/4" (31,8 mm) PLATE MOUNTING 1/8" 1/4" (6,4 mm) 1/2" (12,7 mm) TY-FRB SERIES FIGURE 11 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT 2-7/8" DIA. (73,0 mm) 2-1/4" DIA. (57,2 mm) MOUNTING SPRINKLER CLOSURE SURFACE FITTING FACE OF (12,7±3,2 mm) 1/2±1/8" 1-5/16" (33,3 mm) 1-1/16" (27,0 mm) MOUNTING PLATE (3,2 mm) 1/8" 1/2" (12,7 mm) 1/4" (6,4 mm) SERIES TY-FRB FIGURE 12 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 INCH NPT 2-7/8" DIA. (73,0 mm) 2-1/4" DIA. (57,2 mm) MOUNTING SPRINKLER CLOSURE SURFACE FITTING FACE OF (15,9±6,4 mm) 5/8±1/4" MOUNTING PLATE 1-5/16" (33,3 mm) 13/16" (20,6 mm) (3,2 mm) 1/8" 3/4" (19,1 mm) 1/4" (6,4 mm) SERIES TY-FRB FIGURE 13 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 30 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 INCH NPT WRENCH RECESS (END "A" USED FOR 1/2" NPT MODELS) WRENCH RECESS (END "B" USED FOR 3/4" NPT MODELS) RECESS WRENCH PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREAFIGURE 14 W-TYPE 6 SPRINKLER WRENCH FIGURE 15 W-TYPE 7 RECESSED SPRINKLER WRENCH Inspections of corrosion-resistant sprinklers are recommended at close range, instead of from the floor level per NFPA. Inspection at close range can better determine the exact sprin- kler condition and the long-term integ- rity of the corrosion-resistant material, which can be affected by the corrosive conditions present. Copyright © 2007-2010 Tyco Fire Suppression & Building Products. All rights reserved. TFP171 Page 10 of 10 Limited Warranty Products manufactured by Tyco Fire Suppression & Building Products (TFSBP) are warranted solely to the original Buyer for ten (10) years against defects in material and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by TFSBP. No warranty is given for prod- ucts or components manufactured by companies not affiliated by ownership with TFSBP or for products and com- ponents which have been subject to misuse, improper installation, corro- sion, or which have not been installed, maintained, modified or repaired in accordance with applicable Standards of the National Fire Protection Associa- tion, and/or the standards of any other Authorities Having Jurisdiction. Mate- rials found by TFSBP to be defective shall be either repaired or replaced, at TFSBP’s sole option. TFSBP neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of products. TFSBP shall not be responsible for sprinkler system design errors or inaccurate or incomplete infor- mation supplied by Buyer or Buyer’s representatives. In no event shall TFSBP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, indirect, special or consequential dam- ages, including but not limited to labor charges, regardless of whether TFSBP was informed about the possibility of such damages, and in no event shall TFSBP’s liability exceed an amount equal to the sales price. The foregoing warranty is made in lieu of any and all other warranties, express or implied, including warranties of mer- chantability and fitness for a particular purpose. This limited warranty sets forth the exclusive remedy for claims based on failure of or defect in products, materi- als or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full extent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. Ordering Procedure Contact your local distributor for availability. When placing an order, indicate the full product name and Part Number (P/N). Sprinkler Assemblies with NPT Thread ConnectionsSpecify: (Specify Model/SIN), Quick Response, (specify K-factor), (specify temperature rating), Series TY-FRB (specify Pendent or Upright) Sprinkler with (specify type of finish or coating), P/N (specify from Table D). Recessed Escutcheon: Specify: Style (10, 20, 30, or 40) Recessed Escutcheon with (specify*) finish, P/N (specify*). Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387. Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001. * Refer to Technical Data Sheet TFP770. TABLE D PART NUMBER SELECTION SERIES TY-FRB PENDENT AND UPRIGHT SPRINKLERS P/N 57 – XXX – X – XXX SPRINKLER FINISH 1 NATURAL BRASS 4 WHITE POLYESTER 3 WHITE (RAL9010)* 9 CHROME PLATED 7 LEAD COATED TEMPERATURE RATINGS 135 135°F (57°C) 155 155°F (68°C) 175 175°F (79°C) 200 200°F (93°C) 286 286°F (141°C) MODEL/SIN 330 2.8K UPRIGHT (1/2”NPT)TY1131 331 2.8K PENDENT (1/2”NPT)TY1231 340 4.2K UPRIGHT (1/2”NPT)TY2131 341 4.2K PENDENT (1/2”NPT)TY2231 370 5.6K UPRIGHT (1/2”NPT)TY3131 371 5.6K PENDENT (1/2”NPT)TY3231 390 8.0K UPRIGHT (3/4”NPT)TY4131 391 8.0K PENDENT (3/4”NPT)TY4231 360 8.0K UPRIGHT (1/2”NPT)TY4831* 361 8.0K PENDENT (1/2”NPT)TY4931* * Eastern Hemisphere sales only. Series DS-1 Dry-Type Sprinklers Quick Response, Standard Coverage 5.6 K-factor, 3/4 and 1-Inch NPT Page 1 of 10 OCTOBER 2010 TFP510 IMPORTANT Always refer to Technical Data Sheet TFP700 for the “INSTALLER WARNING” that provides cautions with respect to handling and in- stallation of sprinkler systems and components. Improper handling and installation can permanently dam- age a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Technical Services 800-381-9312 | +1-401-781-8220 www.tyco-fire.com General Description The TYCO Series DS-1, 5.6 K-factor, 3/4 and 1-Inch NPT, Quick Response, Standard Coverage, Dry-Type Sprink- lers are decorative, 3-mm glass bulb automatic sprinklers de signed for com- mercial use. Dry-Type Sprinklers are typically used where: • pendent sprinklers are re quired on dry pipe systems that are exposed to freezing tempera tures; for example, sprinkler drops from un heated por- tions of buildings. • sprinklers and/or a portion of the con- necting piping are exposed to freezing temperatures; for example, sprinkler drops from wet sys tems into freezers, sprinkler sprigs from wet systems into unheated attics, or horizontal piping extensions through a wall to protect an unheated areas such as loading docks, overhangs, and building exteriors. • sprinklers are used on sys tems that are seasonally drained to avoid freezing; for example, vacation areas. NOTICE The Series DS-1 Dry-Type Sprinklers described herein must be installed and maintained in compliance with this document, as well as with the applica- ble standards of the National Fire Protection Association, in addition to the standards of any authorities hav ing jurisdiction. Failure to do so may impair the performance of these de vices. Owners are responsible for maintain ing their fire protection system and de vices in proper operating condition. The in- stalling contractor or sprinkler manu- facturer should be contacted with any questions. The Series DS-1 Dry-Type Sprinklers must only be installed in fittings that meet the requirements of the Design Criteria section. Model/Sprinkler Identification Numbers (SINs) 3/4-Inch NPT: TY3935 - Pendent TY3735 - Horizontal Sidewall 1-Inch NPT: TY3235 - Pendent TY3135 - Upright TY3335 - Horizontal Sidewall TFP510 Page 2 of 10 1-INCH NPT TY3235 Pendent with Standard Recessed Escutcheon (Figure 4) TY3235 Pendent with Standard Escutcheon (Figure 3) with Deep Escutcheon (Figure 5) without Escutcheon (Figure 6) TY3135 Upright without Escutcheon (Figure 7) TY3335 Horizontal Sidewall with Top of Deflector-to-Ceiling Distance of 4 to 12 inches (100 to 300 mm) with Standard Escutcheon (Figure 8) with Deep Escutcheon (Figure 9) without Escutcheon (Figure 10) Temperature Rating Bulb Color Code Finish Natural Brass Chrome Plated White Polyester Natural Brass Chrome Plated White Polyester Natural Brass Chrome Plated White Polyester 135°F (57°C)Orange 1, 2, 3 1, 2 1, 2, 3 1, 2 1*, 2*, 3**1*, 2* 155°F (68°C)Red 1, 2, 3 1, 2 1, 2, 3 1, 2 1*, 2*, 3**1*, 2* 175°F (79°C)Yellow 1, 2, 3 1, 2 1, 2, 3 1, 2 1*, 2*, 3**1*, 2* 200°F (93°C)Green 1, 2, 3 1, 2 1, 2, 3 1, 2 1*, 2*, 3**1*, 2* 286°F (141°C)Blue N/A 1, 2, 3 1, 2 1*, 2*, 3** 1*, 2* TABLE B 1-INCH NPT AND ISO 7-R1, SERIES DS-1 QUICK RESPONSE, STANDARD COVERAGE DRY-TYPE SPRINKLERS LABORATORY LISTINGS AND APPROVALS Notes: 1. Listed by Underwriters Laboratories, Inc. (maximum order length of 48 inches). 2. Listed by Underwriters Laboratories for use in Canada (maximum order length of 48 inches). 3. Approved by Factory Mutual Research Corporation (maximum order length of 48 inches). 4. The Upright Sprinkler without an Escutcheon (TY3135) is available in 1-Inch NPT only. * Light and Ordinary Hazard Occupancies Only / ** Light Hazard Occupancies Only / N/A - Not Available TABLE A 3/4-INCH NPT, SERIES DS-1 QUICK RESPONSE, STANDARD COVERAGE DRY-TYPE SPRINKLERS LABORATORY LISTINGS AND APPROVALS 3/4-INCH NPT TY3935 Pendent with Standard Recessed Escutcheon (Figure 4) TY3935 Pendent with Standard Escutcheon (Figure 3) with Deep Escutcheon (Figure 5) without Escutcheon (Figure 6) TY3735 Horizontal Sidewall with Top of Deflector-to-Ceiling Distance of 4 to 12 inches (100 to 300 mm) with Standard Escutcheon (Figure 8) with Deep Escutcheon (Figure 9) without Escutcheon (Figure 10) Temperature Rating Bulb Color Code Finish Natural Brass Chrome Plated White Polyester Natural Brass Chrome Plated White Polyester Natural Brass Chrome Plated White Polyester 135°F (57°C)Orange 1, 2 1, 2 1*, 2* 155°F (68°C)Red 1, 2 1, 2 1*, 2* 175°F (79°C)Yellow 1, 2 1, 2 1*, 2* 200°F (93°C)Green 1, 2 1, 2 1*, 2* 286°F (141°C)Blue N/A 1, 2 1*, 2* Notes: 1. Listed by Underwriters Laboratories, Inc. (maximum order length of 48 inches). 2. Listed by Underwriters Laboratories for use in Canada (maximum order length of 48 inches). * Light and Ordinary Hazard Occupancies Only / N/A - Not Available TFP510 Page 3 of 10 WATER TUBE VENT HOLE GUIDE TUBE SEALING PLUG WITH DEFLECTOR SPRING ASSEMBLY FRAME 3 mm BULB INSERT YOKE SCREW INLET CASING BULB COMPRESSION SEAT INLET BAND WATER TUBE VENT HOLE GUIDE TUBE 3 mm BULB INSERT SPRING SCREW INLET SEALING PLUG WITH CASING DEFLECTOR BULB YOKE COMPRESSION SEAT ASSEMBLY FRAME SPRING PLUG INLET BAND FIGURE 2 SERIES DS-1, 1-INCH NPT AND ISO 7-R1, QUICK RESPONSE DRY-TYPE SPRINKLER ASSEMBLY FIGURE 1 SERIES DS-1, 3/4-INCH NPT, QUICK RESPONSE DRY-TYPE SPRINKLER ASSEMBLY Technical Data Approvals UL and C-UL Listed FM Approved Refer to Tables A and B. Maximum Working Pressure 175 psi (12,1 bar) Inlet Thread Connection 3/4-Inch NPT 1-Inch NPT or ISO 7-R1 Discharge Coefficient K = 5.6 GPM/psi1/2 (80,6 LPM/bar1/2) Temperature RatingsRefer to Tables A and B. Finishes Sprinkler: Natural Brass, Chrome Plated, White Polyester Escutcheon: White Coated, Chrome Plated, Brass Plated Physical Characteristics Inlet ..................... Copper Plug .................... Copper Yoke ..............Stainless Steel Casing .....Galvanized Carbon Steel Insert .................. Bronze Bulb Seat ...........Stainless Steel Bulb ......................Glass Compression Screw ........Bronze Deflector ................ Bronze Frame ...................Bronze Guide Tube .........Stainless Steel Water Tube .........Stainless Steel Spring .............Stainless Steel Plug Spring*. . . . . . . . .Stainless Steel Sealing Assembly ........ Beryllium Nickel w/Teflon** Escutcheon .........Carbon Steel Patents U.S.A. Patent No. 5,188,185 *For 3/4-Inch NPT only **Registered trademark of DuPont TFP510 Page 4 of 10 FIGURE 5 TY3235 AND TY3935 PENDENT WITH DEEP ESCUTCHEON ORDER LENGTHS: INCREMENTS 4-1/4" ± 1/8" (108,0 ± 3,2 mm) IN 1/4" (6,4 mm) (12,7 to 1168,4 mm) 1/2" to 46" FACE OF CEILING (88,9 mm) 3-1/2" DIA. 2-1/2" DIA. (63,5 mm) FITTING FACE OF SPRINKLER CRITERIA SECTION) (REFER TO DESIGN SPRINKLER FITTING FIGURE 6 TY3235 AND TY3935 PENDENT WITHOUT ESCUTCHEON FIGURE 3 TY3235 AND TY3935 PENDENT WITH STANDARD ESCUTCHEON FIGURE 4 TY3235 AND TY3935 PENDENT WITH STANDARD RECESSED ESCUTCHEON 2-1/4" DIA. (57,2 mm) 1-3/8" ± 1/8" (34,9 ± 3,2 mm) 2-7/8" DIA. (73,0 mm) IN 1/4" (6,4 mm) 3-3/4" to 48" INCREMENTS (95,3 to 1219,2 mm) ORDER LENGTHS: SPRINKLER FACE OF FITTING CEILING FACE OF CRITERIA SECTION) (REFER TO DESIGN SPRINKLER FITTING ORDER LENGTHS: (69,9 to 1219,2 mm) 2-3/4" to 48" IN 1/4" (6,4 mm) INCREMENTS FITTING FACE OF SPRINKLER SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) (76,2 mm) 3" DIA. 1-3/4" DIA. (44,5 mm) (55,6 ± 3,2 mm) 2-3/16" ± 1/8" CEILING FACE OF SPRINKLER FACE OF FITTING (127,0 to 1219,2 mm) INCREMENTS IN 1/4" (6,4 mm) ORDER LENGTHS: 5" to 48" DEFLECTOR TO CEILING 1-3/4" (44,5 mm) MINIMUM SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) FIGURE 7 TY3135 UPRIGHT WITHOUT ESCUTCHEON — 1-INCH NPT ONLY — TOP OF DEFLECTOR CRITERIA SECTION) (REFER TO DESIGN SPRINKLER FITTING SPRINKLER FITTING FACE OF IN 1/4" (6,4 mm) INCREMENTS (127,0 to 1219,2 mm) 5" to 48" ORDER LENGTHS: TFP510 Page 5 of 10 Operation When the TYCO Series DS-1 Dry-Type Sprinkler is in service, water is prevent- ed from entering the assembly by the Plug with Sealing Assembly in the Inlet of the Sprinkler. See Figures 1 and 2. The glass Bulb contains a fluid that ex- pands when ex posed to heat. When the rated tem perature is reached, the fluid expands sufficiently to shatter the glass Bulb, and the Bulb Seat is released. The compressed Spring is then able to ex pand and push the Water Tube as well as the Guide Tube outward. This action simultaneously pulls inward on the Yoke, withdrawing the Plug with Sealing Assembly from the Inlet and allowing the sprin kler to activate and flow water. Design Criteria The TYCO Series DS-1 Sprinklers are intended for use in fire sprinkler sys- tems designed in accordance with the standard installation rules recognized by the applicable Listing or Approval agency; for example, UL Listing is based on NFPA 13 requirements. Sprinkler Fittings Install the 3/4 or 1-inch NPT Series DS-1 Dry-Type Sprinklers in the 3/4 or 1-inch NPT outlet or run of the follow- ing fittings: • malleable or ductile iron threaded tee fittings that meet the dimensional re- quirements of ANSI B16.3 (Class 150) • cast iron threaded tee fittings that meet the dimensional requirements of ANSI B16.4 (Class 125). Do not install the DS-1 Sprinklers into an elbow fittings. The Inlet of the sprin- kler can contact the interior of the el- bow, potentially damaging the Inlet seal. The unused outlet of the threaded tee is plugged as shown in Figures 12 and 13. You can also install the Series DS-1 Dry-Type Sprinklers in the 3/4 or 1-inch NPT outlet of a GRINNELL Figure 730 Mechanical Tee. However, the use of the Figure 730 Tee for this arrangement is limited to wet pipe systems. The configuration shown in Figure 12 is only applicable for wet pipe systems where the sprinkler fitting and water- filled pipe above the sprinkler fitting are not subject to freezing and where the length of the Dry-Type Sprinkler has the minimum exposure length depicted in Figure 11. Refer to the Exposure Length section. 3.5° 5/16" (7,9 mm) CENTERLINE OF WATERWAY (76,2 mm) 3" DIA. 1-3/4" DIA. (44,5 mm) FITTING SPRINKLER FACE OF SPRINKLER FITTING CRITERIA SECTION) (REFER TO DESIGN 4" ± 1/8" (101,6 ± 3,2 mm) 2-3/4" to 48" (69,9 to 1219,2 mm) IN 1/4" (6,4 mm) INCREMENTS ORDER LENGTHS: SURFACE MOUNTING FACE OF (88,9 mm) 3-1/2" DIA. 2-1/2" DIA. (63,5 mm) 4-13/16" ± 1/8" (122,2 ± 3,2 mm) 3.5° 5/16" (7,9 mm) CENTERLINE OF WATERWAY FACE OF SPRINKLER FITTING 1/2" to 45-3/4" (12,7 to 1162,1 mm) IN 1/4" (6,4 mm) INCREMENTS ORDER LENGTHS:FACE OF MOUNTING SURFACE SPRINKLER FITTING CRITERIA SECTION) (REFER TO DESIGN 3.5°5/16" (7,9 mm) CENTERLINE OF WATERWAY FITTING SPRINKLER FACE OF 2-1/4" (57,2 mm) DEFLECTOR TO 5-1/2" to 48" (139,7 to 1219,2 mm) IN 1/4" (6,4 mm) INCREMENTS ORDER LENGTHS: MINIMUM MOUNTING SURFACE SPRINKLER FITTING CRITERIA SECTION) (REFER TO DESIGN FIGURE 8 TY3335 AND TY3735 HORIZONAL SIDEWALL WITH STANDARD ESCUTCHEON FIGURE 9 TY3335 AND TY3735 HORIZONAL SIDEWALL WITH DEEP ESCUTCHEON FIGURE 10 TY3335 AND TY3735 HORIZONAL SIDEWALL WITHOUT ESCUTCHEON TFP510 Page 6 of 10 For wet pipe system installations of the 1-inch NPT Series DS-1 Dry-Type Sprinklers connected to CPVC piping, use only the following TYCO CPVC fittings: • 1" x 1" NPT Female Adapter (P/N 80145) • 1" x 1" x 1" NPT Sprinkler Head Adapter Tee (P/N 80249). For wet pipe system installations of the the 3/4-inch NPT Series DS-1 Sprinklers connected to CPVC pip- ing, use in the 3/4" x 3/4" NPT Female Adapter (P/N 80142). For dry pipe system installations, use only the side outlet of maximum 2-1/2- inch reducing tee when locating the Series DS-1 Sprinklers directly below the branch line. Otherwise, use the con- figuration shown in Figure 13 to assure complete water drainage from above the Series DS-1 Dry-Type Sprinklers and the branch line. Failure to do so may result in pipe freezing and water damage. Ambient Temperature Exposed to Discharge End of Sprinkler Temperatures for Heated Area(a) 40°F (4°C)50°F (10°C)60°F (16°C) Minimum Exposed Barrel Length, Inches (mm)(b) 40°F (4°C)0 0 0 30°F (-1°C)0 0 0 20°F (-7°C)4 (100)0 0 10°F (-12°C)8 (200)1 (25)0 0°F (-18°C)12 (305)3 (75)0 -10°F (-23°C)14 (355)4 (100)1 (25) -20°F (-29°C)14 (355)6 (150)3 (75) -30°F (-34°C)16 (405)8 (200)4 (100) -40°F (-40°C)18 (455)8 (200)4 (100) -50°F (-46°C)20 (510)10 (255)6 (150) -60°F (-51°C)20 (510)10 (255)6 (150) Notes: (a) For protected area temperatures that occur between values listed above, use the next cooler temperature. (b) These lengths are inclusive of wind velocities up to 30 mph (18,6 kph). TABLE C MINIMUM RECOMMENDED LENGTHS OF EXPOSED SPRINKLER BARRELS IN WET PIPE SYSTEMS NOTICE Do not install the Series DS-1 Dry-Type Sprinkler into any other type fitting without first consulting the Technical Services Department. Failure to use the appropriate fitting may result in one of the following: • Failure of the sprinkler to operate prop- erly due to formation of ice over the inlet Plug or binding of the Inlet Plug. • Insufficient engagement of the Inlet pipe threads with consequent leakage. Drainage In accordance with the minimum requirements of the National Fire Protection Association for dry pipe sprinkler systems, branch, cross, and feed-main piping connected to Dry Sprinklers and subject to freezing tem- peratures must be pitched for proper drainage. Exposure Length When using Dry Sprinklers in wet pipe sprinkler systems to protect areas sub- ject to freezing temperatures, use Table C to determine a sprinkler’s appropriate exposed barrel length to prevent water from freezing in the connecting pipes due to conduction. The exposed bar- rel length measurement must be taken from the face of the sprinkler fitting to the surface of the structure or insula- tion that is exposed to the heated area. Refer to Figure 11 for an example. Clearance Space In accordance with Section 8.4.9.2 of the 2010 edition of NFPA 13, when connecting an area subject to freez- ing and an area containing a wet pipe sprinkler system, the clearance space around the sprinkler barrel of Dry-Type Sprinklers must be sealed. Due to tem- perature differences between two ar- eas, the potential for the formation of condensation in the sprinkler and sub- sequent ice build-up is increased. If this condensation is not controlled, ice build-up can occur that might damage the dry-type sprinkler and/or prevent proper operation in a fire situation. Use of the Model DSB-2 Dry Sprinkler Boot, described in technical data sheet TFP591 and shown in Figures 14 and 15, can provide the recommended seal. TFP510 Page 7 of 10 FIGURE 12 SPRINKLER FITTING IN HEATED AREA SIDE OUTLET PLUGGED TO WET SYSTEM FITTING (SEE DESIGN CRITERIA SECTION) SPRINKLERDSB-2 INTENDED FOR FREEZER STRUCTURES HEATED AREA INSULATED FREEZER STRUCTURE (ENDS ON OPPOSING SIDES OF STRAP TIES BOOT) ADHESIVE SHOWN WITH STANDARD ESCUTCHEON DS-1 1-3/4" DIA. (44,5 mm) CLEARANCE HOLE DSB-2 BOOT FIGURE 15 MODEL DSB-2 SPRINKLER BOOT WITH SIDEWALL SERIES DS-1 DRY SPRINKLER (SEE DESIGN CRITERIA SECTION) FACE OF SPRINKLER FITTING LENGTH EXPOSURE DSB-2 INTENDED FOR FREEZER STRUCTURES HEATED AREA FIGURE 11 EXPOSURE LENGTH FIGURE 13 SPRINKLER FITTING IN UNHEATED AREA RUN OUTLET PLUGGED TO DRY SYSTEM DSB-2 INTENDED FOR FREEZER STRUCTURES FITTING (SEE DESIGN CRITERIA SECTION) SPRINKLER AREA SUBJECT TO FREEZING FIGURE 14 MODEL DSB-2 SPRINKLER BOOT WITH PENDENT SERIES DS-1 DRY SPRINKLER INSULATED FREEZER STRUCTURE (ENDS ON OPPOSING SIDES OF STRAP TIES BOOT) ADHESIVE SHOWN WITH STANDARD ESCUTCHEON DS-1 1-3/4" DIA. (44,5 mm) CLEARANCE HOLE DSB-2 BOOT TFP510 Page 8 of 10 Installation The TYCO Series DS-1 Dry-Type Sprinklers must be installed in accor- dance with the following instructions. NOTICE The Series DS-1 Dry-Type Sprinkler must only be installed in fittings that meet the requirements of the Design Criteria section. Refer to the Design Criteria section for other important re- quirements regard ing piping design and sealing of the clearance space around the Sprinkler Casing. Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F (57°C) rating to 1/8 inch (3,2 mm) for the 286°F (141°C) rating. • Obtain a leak-tight 3/4-inch NPT sprin- kler joint by applying a minimum-to- maximum torque of 10 to 20 ft. lbs. (13,4 to 26,8 Nm). • Obtain a leak-tight 1 inch NPT sprin- kler joint by applying a minimum-to- maximum torque of 20 to 30 ft. lbs. (26,8 to 40,2 Nm). Higher levels of torque can distort the sprinkler Inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in an Escutcheon Plate by under or over- tightening the Sprinkler. Re-adjust the position of the sprinkler fitting to suit. 1. Install pendent sprinklers only in the pendent position, and install upright sprinklers only in the upright posi- tion. The deflector of a pendent or upright sprin kler must be parallel to the ceiling. Install horizontal sidewall sprin- klers in the horizontal position with their centerline of waterway perpen- dicular to the back wall and paral- lel to the ceiling. Ensure the word “TOP” on the De flector faces the ceiling. 2. With a non-hardening pipe-thread sealant such as Teflon1 tape applied to the Inlet threads, hand-tighten the sprinkler into the sprinkler fitting. 3. Wrench-tighten the sprinkler using either: • a pipe wrench on the Inlet Band or the Casing (Figures 1 and 2) • the W-Type 7 Sprinkler Wrench on the Wrench Flat (Figure 16). 1 Registered trademark of DuPont Apply the Wrench Recess of the W-Type 7 Sprinkler Wrench to the Wrench Flat. Note: If sprinkler removal becomes necessary, remove the sprinkler using the same wrenching meth- od noted above. Sprinkler remov- al is easier when a non-hardening sealant was used and torque guide- lines were followed. After removal, inspect the sprinkler for damage. 4. After installing the ceiling or wall and applying a celing finish, slide on the outer piece of the Escutcheon until it comes in contact with the ceiling or wall. Do not lift the ceiling panel out of its normal position. When using the Deep Escutcheon, hold the outer piece in contact with the mounting surface (ceiling or wall). Then rotate the inner piece approximately 1/4 turn with respect to the outer piece, to hold the Deep Escutcheon firmly together. Care and Maintenance The TYCO Series DS-1 Dry-Type Sprinklers must be maintained and ser- viced in accordance with the following instructions. NOTICE Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection sys- tems from the proper authorities and notify all personnel who may be affect- ed by this action. Absence of the outer piece of an es- cutcheon, which is used to cover a clearance hole, can delay the time to sprinkler operation in a fire situation. A Vent Hole is provided in the Bulb Seat (Figures 1 and 2) to indicate if the Dry- Type Sprinkler is remaining dry. Evi- dence of leakage from the Vent Hole in- dicates potential leakage past the Inlet seal and the need to remove the sprin- kler to determine the cause of leakage; for example, an improper installation or an ice plug. Close the fire protec- tion system control valve and drain the system before removing the sprinkler. Exercise care to avoid dam age before, during, and after instal lation. Never paint, plate, coat, or otherwise alter automatic sprinklers after they leave the factory. Never repaint factory-painted Cover Plates. When necessary, replace cov- er plates with factory-painted units. Non-factory applied paint can adverse- ly delay or prevent sprinkler operation in the event of a fire. Replace sprinklers that: • were damaged by dropping, striking, wrench twisting, wrench slippage, or the like. • were modified or over-heated. • have cracked bulbs or have lost liquid from the bulbs. Refer to the Installation Section in this data sheet. • are leaking or exhibiting visible signs of corrosion. Responsibility lies with owners for the in spection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protec tion Association (for example, NFPA 25), in addition to the standards of any other authorities having jurisdiction. The installing con- tractor or sprinkler manufacturer should be contacted relative to any questions. Automatic sprinkler systems are recom- mended to be inspected, tested, and maintained by a qualified Inspection Service in accordance with local re- quirements and/or national codes. RECESS WRENCH FLAT WRENCH WITH SPRINKLER ENGAGEMENT IN TO ENSURE WRENCHING AREA PUSH WRENCH FIGURE 16 W-TYPE 7 SPRINKLER WRENCH TFP510 Page 9 of 10 Limited Warranty Products manufactured by Tyco Fire Suppression & Building Products (TFSBP) are war ranted solely to the original Buyer for ten (10) years against defects in mate rial and workman- ship when paid for and properly in- stalled and maintained under normal use and service. This warranty will ex- pire ten (10) years from date of ship- ment by TFSBP. No warranty is given for products or com ponents manu- factured by companies not affiliated by ownership with TFSBP or for prod- ucts and components which have been subject to misuse, improper in- stallation, corrosion, or which have not been installed, maintained, modi- fied or repaired in accordance with ap- plicable Standards of the National Fire Protection Association, and/or the stan- dards of any other Authorities Having Jurisdiction. Materials found by TFSBP to be defective shall be either repaired or replaced, at TFSBP's sole option. TFSBP neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of prod ucts. TFSBP shall not be responsible for sprinkler system design errors or inac curate or incomplete information sup plied by Buyer or Buyer’s repre sentatives. In no event shall TFSBP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, indirect, special or consequential dam- ages, including but not limited to labor charges, regardless of whether TFSBP was informed about the possibility of such damages, and in no event shall TFSBP's liability exceed an amount equal to the sales price. The foregoing warranty is made in lieu of any and all other warranties, express or implied, including warranties of mer- chantability and fitness for a particular purpose. This limited warranty sets forth the ex- clusive remedy for claims based on fail- ure of or defect in products, materi als or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full ex- tent permitted by law. The invalidity, in whole or part, of any portion of thiswar- ranty will not affect the remainder. Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indicate the full product name and Part Number (P/N). Dry-Type Sprinklers Specify this dry-type sprinkler as follows: • Model/SIN from Page 1 • Quick Response, Standard Cover age, Dry-Type Sprinkler • Deflector Style • 5.6 K-Factor • Order Length Dry-Type Sprinklers are furnished based upon Order Length as mea- sured per Figures 3 through 10. After taking the measurement, round it to the nearest 1/4 inch increment. • Inlet Connection: 3/4-inch NPT, 1-inch NPT, or ISO 7-R1 • Temperature Rating • Sprinkler Finish • Escutcheon Style and Finish, as applicable • Part Number (P/N) from Table C The Upright Sprinkler without an Escutcheon (TY3135) is available in 1-Inch NPT only. Part Numbers are for 3/4-inch and 1-inch NPT stand ard order sprin- klers. Orders for all other sprinkler assemblies must be accompanied by a complete description. Refer to the Price List for a complete listing of Part Numbers. Sprinkler Wrench Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001. Sprinkler Boot Specify: Model DSB-2 Dry Sprinkler Boot, P/N 63-000-0-002. This Part Number includes one Boot, two Strap Ties, and 1/3 oz. of Adhesive. The quantity of adhesive is sufficient for installing one Boot. TFP510 Page 10 of 10 Copyright ©2009 - 2010 Tyco Fire Suppression & Building Products. All rights reserved. TABLE C PART NUMBER SELECTION SERIES DS-1, 3/4 AND 1-INCH NPT, QUICK RESPONSE, STANDARD COVERAGE, DRY-TYPE SPRINKLERS (Use Prefix “I” for ISO 7-R1 Connection; for example, I-60-361-1-180) P/N 60 – XXX – X – XXX NOTES (1). Escutcheon Finish applies to sprinklers provided with escutcheons. (2). 286°F (141°C) temperature rating applies to non-recessed sprinkler assemblies. (3). Dry-Type Sprinklers are furnished based upon “Order Length” as measured per Figures 3 through 10, as applicable, and for each individual sprinkler where it is to be installed. After the measurement is taken, round it to the nearest 1/4 inch increment. SAMPLE ORDER LENGTHS (3) 055 5.50” 082 8.25” 180 18.00” 187 18.75” 372 37.25” 480 48.00” MODEL/SIN 01 Pendent with Standard Escutcheon (3/4" NPT) TY3935 (Figure 3) 02 Pendent with Deep Escutcheon (3/4" NPT) TY3935 (Figure 5) 03 Pendent with Standard Recessed Escutcheon (3/4" NPT) TY3935 (Figure 4) 04 Pendent without Escutcheon (3/4" NPT) TY3935 (Figure 6) 05 Sidewall with Standard Escutcheon (3/4" NPT) TY3735 (Figure 8) 06 Sidewall with Deep Escutcheon (3/4" NPT) TY3735 (Figure 9) 07 Sidewall without Escutcheon (3/4" NPT) TY3735 (Figure 10) 36 Pendent with Standard Escutcheon (1" NPT) TY3235 (Figure 3) 33 Pendent with Deep Escutcheon (1" NPT) TY3235 (Figure 5) 37 Pendent with Standard Recessed Escutcheon (1" NPT) TY3235 (Figure 4) 32 Pendent without Escutcheon (1" NPT) TY3235 (Figure 6) 34 Sidewall with Standard Escutcheon (1" NPT) TY3335 (Figure 8) 43 Sidewall with Deep Escutcheon (1" NPT) TY3335 (Figure 9) 44 Sidewall without Escutcheon (1" NPT) TY3335 (Figure 10) 38 Upright without Escutcheon (1" NPT) TY3135 (Figure 7) SPRINKLER FINISH ESCUTCHEON FINISH (1) 1 NATURAL BRASS WHITE 4 WHITE POLYESTER WHITE 9 CHROME PLATED CHROME 0 CHROME PLATED WHITE 2 NATURAL BRASS BRASS PLATED TEMPERATURE RATINGS (2) 0 135°F (57°C) 1 155°F (68°C) 2 175°F (79°C) 3 200°F (93°C) 4 286°F (141°C) ES-A-C400/C400N/C400Z Job Name________________________________________________Contractor______________________________________________ Job Location______________________________________________Approval________________________________________________ Engineer__________________________________________________Contractor’s P.O.No.______________________________________ Approval__________________________________________________Representative__________________________________________ Features •Extremely Compact Design •70% Lighter than Traditional Designs •304 (Schedule 40) Stainless Steel Housing & Sleeve •Groove Fittings Allow Integral Pipeline Adjustment •Patented Link Check Provides Lowest Pressure Loss •Unmatched Ease of Serviceability •Available with Grooved Butterfly Valve Shutoffs •May be Used for Horizontal, Vertical or N Pattern Installations •Replaceable Check Disc Rubber C400 OSY C400N BFG Ames product specifications in U.S.customary units and metric are approximate and are provided for reference only.For precise measurements,please contact Ames Technical Service.Ames reserves the right to change or modify product design,construction,specifications,or materials without prior notice and without incurring any obligation to make such changes and modifications on Ames products previously or subsequently sold. The Colt C400, C400N, C400Z Reduced Pressure Zone Assemblies provide protection to the potable water system from contamination in accordance with national plumbing codes. The Colt C400, C400N, C400Z are normally used in health hazard applications for protection against backsiphonage, backpressure and the fouling of either check valve. Specifications The Colt C400, C400N, C400Z Reduced Pressure Zone Assemblies shall consist of two independent Link Check modules, a differential pressure relief valve located between and below the two modules, two drip tight shutoff valves, and required test cocks. Link Check modules and relief valve shall be contained within a sleeve accessible single housing constructed from 304 (Schedule 40) stainless steel pipe with groove end connections. Link Checks shall have reversible elastomer discs and in operation produce drip tight closure against the reverse flow of liquid caused by backpressure or backsiphonage. Assembly shall be Colt C400, C400N, C400Z as manufactured by the Ames Company. ColtTM Series C400, C400N, C400Z Reduced Pressure Zone Assemblies Sizes: 21⁄2" – 10" (65 – 250mm) www.amesfirewater.com Dimensions — Weights Configurations •Horizontal • “Z” pattern horizontal •“N” pattern horizontal Materials •Housing & Sleeve: 304 (Schedule 40) Stainless Steel •Elastomers: EPDM, Silicone and Buna ‘N’ •Link Checks: Noryl®, Stainless Steel •Check Discs: Reversible Silicone or EPDM •Test Cocks: Bronze Body Nickel Plated •Pins & Fasteners: 300 Series Stainless Steel •Springs: Stainless Steel Available Models Suffix: NRS –non-rising stem resilient seated gate valves OSY – UL/FM outside stem and yoke resilient seated gate valves BFG – UL/FM grooved gear operated butterfly valves with tamper switch Pressure — Temperature Temperature Range: 33°F – 140°F (5°C – 60°C) Maximum Working Pressure: 175psi (12 bars) Note: When instaling a drain line on Series C400 backflow preventer use 400/500 air gap. See ES-A-AG/EL/TC for additional information. M G H J I P C400 C400BFG SIZE (DN)DIMENSIONSWEIGHT AC (OSY)C (NRS)DGHIJMPC400C400N NRSOSYNRSOSY in.mmin.mmin.mmin.mmin.mmin.mmin.mmin.mmin.mmin.mmin.mmlbs.kgs.lbs.kgs.lbs.kgs.lbs.kgs. 21⁄2 6531787163⁄8 41693⁄8 23861⁄2 165291⁄16 73822559151⁄2 393813⁄16 223219⁄16 54893⁄16 23411854128581265713662 3803111⁄16 805187⁄8 479101⁄4 260611⁄16 170301⁄4 768223⁄4 578171⁄8 43593⁄16 233231⁄8 587101⁄2 26713461148671476716173 4 1003311⁄16 856223⁄4 578123⁄16 31071783383824610181⁄2 470915⁄16 252261⁄2 673113⁄16 28416474164741878518785 6 150441118301⁄8 76516 40681⁄2 216443⁄41137333⁄4 857233⁄16 589131⁄16 332323⁄4 83215381 276125298135317144339154 8 200501270373⁄4 9591915⁄16 506911⁄16 246541⁄81375405⁄8 1032277⁄16 6971511⁄16 399371⁄8 943173⁄16 437 441200483219516234558253 10250571⁄2 1460453⁄4 11622313⁄16 605113⁄16 285661676501270321⁄2 826175⁄16 440463⁄8 117820 508 723328783355893405950431 SIZE (DN)DIMENSIONSWEIGHT GHIJMPC400N,C400Z in.mmin.mmin.mmin.mmin.mmin.mmin.mmlbs.kgs. 21⁄2 65321⁄2 826231⁄2 597151⁄2 39491⁄2 2412113⁄16 5551113⁄16 300 6730 38034 864241⁄2 622165⁄16 414101⁄16 256231⁄8 587121⁄8 308 7032 4 100355⁄8 90526660173⁄16 4371015⁄16 2792415⁄16 634125⁄8 321 8739 6 150461⁄2 11813512⁄16 908201⁄2 521131⁄2 343281⁄4 71815382 16073 Noryl® is a registered trademark of General Electric Company. A D C (open) G H J I P M Approvals For additional approval information please contact the factory or visit our website at www.amesfirewater.com Capacity UL/FM Certified Flow Characteristics N&Z Flow characteristics collected using butterfly shutoff valves. See literatue S-Colt-400,500 for gate valve flow characteristics * = Rated Flow ** = UL Tested HorizontalN - PatternZ - Pattern IMPORTANT:INQUIRE WITH GOVERNING AUTHORITIES FOR LOCAL INSTALLATION REQUIREMENTS Listed 28S6 B64.51013 kPapsi 12418 11016 9614 8312 6910 558 416 kPapsi 12418 11016 9614 8312 6910 558 416 kPapsi 11016 9614 8312 6910 558 416 284 050100150200250300350gpm 0 19038057076095011401330lpm 15fps 4.6mps kPapsi 11016 9614 8312 6910 558 416 kPapsi 17926 15222 12418 9614 6910 416 0 100200300400500gpm 0 380760114015201900lpm 15fps 4.6mps 21⁄2" 3" * 0 30060090012001500gpm 0 11402280342045605700lpm 15fps 4.6mps 6" 0 5001000150020002500gpm 0 19003800570076009500lpm 15fps 4.6mps 8" 0 100200300400500600700800gpm 0 380760114015201900228026603040lpm 15fps 4.6mps 4" 0 500100015002000250030003500gpm 0 19003800570076009500 1140013300 lpm fps mps 10" * * * * * kPapsi 12418 11016 9614 8312 6910 558 416 Z N H Z N H N Z H N Z H N Z H N Z H ** ** ** ** ** ** ES-A-C400/C400N/C400Z 0442©Ames Co. 2003Printed in U.S.A. A Division of Watts Regulator Company www.amesfirewater.com 1427 North Market Blvd. • Suite #9 • Sacramento, CA 95834 • Phone: 916-928-0123 • Fax: 916-928-9333 HEADQUARTERS:Ames Fire and Waterworks 1427 North Market Blvd.,Suite #9,Sacramento,CA 95834916 928-0123916 928-9333 Edwards,Platt & Deely,Inc.271 Royal Ave.,Hawthorne,NJ 07506973 427-2898973 427-4246 Edwards,Platt & Deely,Inc.368 Wyandanch Ave.,North Babylon,NY 11703631 253-0600631 253-0303 W.P.Haney Co.,Inc.51 Norfolk Ave.,South Easton,MA 02375508 238-2030508 238-8353 RMIGlenfield Bus.Ctr.,2535 Mechanicsville Tpk.,Richmond,VA 23223804 643-7355804 643-7380 The Joyce Agency,Inc.8442 Alban Rd.,Springfield,VA 22150703 866-3111703 866-2332 Vernon Bitzer Associates,Inc.980 Thomas Drive,Warminster,PA 18974215 443-7500215 443-7573 WMS Sales,Inc.(Main office)9580 County Rd.,Clarence Center,NY 14032716 741-9575716 741-4810 Billingsley & Associates,Inc.2728 Crestview Ave.,Kenner,LA 70062-4829504 602-8100504 602-8106 Billingsley & Associates,Inc.478 Cheyenne Lane,Madison,MS 39110601 856-7565601 856-8390 Mid-America Marketing,Inc.203 Industrial Dr.,Birmingham,AL 35211205 879-3469205 870-5027 Mid-America Marketing,Inc.1364 Foster Avenue,Nashville,TN 37210615 259-9944615 259-5111 Mid-America Marketing,Inc.5466 Old Hwy.78,Memphis,TN 38118901 795-0045901 795-0394 Smith & Stevenson Co.,Inc.4935 Chastain Ave.,Charlotte,NC 28217704 525-3388704 525-6749 Wager Company702-B Industry Rd.,Longwood,FL 32750407 834-4667407 831-0091 Watts2861-B Bankers Industrial Drive,Atlanta,GA 30360770 209-3310770 447-4583 HydroSource8182 Chagrin Rd.,Chagrin Falls,OH 44023440 247-9150440 247-6719 Mid-Continent Marketing Services Ltd.1724 Armitage Ct.,Addison,IL 60101630 953-1211630 953-1067 Soderholm & Associates,Inc.7150 143rd Ave.N.W.,Anoka,MN 55303763 427-9635763 427-5665 Stickler & Associates333 North 121 St.,Milwaukee,WI 53226414 771-0400414 771-3607 Hugh M.Cunningham,Inc.13755 Benchmark,Dallas,TX 75234972 888-3808972 888-3838 Mack McClain & Associates11132 South Towne Square,Suite 202,St.Louis,MO 63123314 894-8188314 894-8388 Mack McClain & Associates,Inc.1450 NE 69th Place,Ste.56 Ankeny,IA 50021515 288-0184515 288-504 Mack McClain & Associates,Inc.15090 West 116th St.,Olathe,KS 66062913 339-6677913 339-9518 OK! Sales,Inc.2200 Blue Creek Dr.,Norman,OK 73026405 360-6161405 360-0092 Phoenix Marketing,Ltd.2416 Candelaria N.E.,Albuquerque,NM 87107505 883-7100505 883-7101 Cisco1738 Neville Street,Orange,CA 92865714 921-9228714 921-0442 Delco Sales,Inc.111 Sand Island Access Rd.,Unit I-10,Honolulu,HI 96819808 842-7900808 842-9625 Hollabaugh Brothers & Associates6915 South 194th St.,Kent,WA 98032253 867-5040253 867-5055 Hollabaugh Brothers & Associates3028 S.E.17th Ave.,Portland,OR 97202503 238-0313503 235-2824 P I R Sales,Inc.3050 North San Marcos Place,Chandler,AZ 85225480 892-6000480 892-6096 Preferred Sales31177 Wiegman Road,Hayward,CA 94544510 487-9755510 476-1595 Rep Masters,Inc.6255 Dexter St.,Commerce City,CO 80022303 286-7575303 286-7576 Watts Industries (Canada) Inc. (Watts Regulator Co.Division)5435 North Service Road,Burlington,Ontario L7L 5H7905 332-4090905 332-7068 D.C.Sales,Ltd.10-6130 4th St.S.E.,Calgary,Alberta T2H 2A6403 253-6808403 259-8331 D.C.Sales,Ltd.11420 142 Street,Edmonton,Alberta T5M 1V1780 496-9495780 496-9621 Hydro-Mechanical Sales,Ltd.3700 Joseph Howe Dr.,Ste.1 Halifax,Nova Scotia B3L 4H7902 443-2274902 443-2275 Hydro-Mechanical Sales,Ltd.297 Collishaw St.,Ste.7 (shipping) Moncton,New Brunswick E1C 9R2506 859-1107506 859-2424 Hydro-Mechanical Sales,Ltd.85 Tolt Rd.,St.Phillips,Newfoundland A1B 3M7709 895-0090709 895-0091 Le Groupe B.G.T.,Inc.23 du Buisson,Pont Rouge,Quebec G3H 1X9418 873-2800418 873-2505 Le Groupe B.G.T.,Inc.86 des Enterprises #208,Boisbriand,Quebec J7G 2T3450 434-9010450 434-9848 Mar-Win Agencies,Ltd.1333 Clifton St.,Winnipeg,Manitoba R3E 2V1204 775-8194204 786-8016 Northern Mechanical SalesP.O.Box 280 (mailing) 163 Pine St.(shipping),Garson,Ontario P3L 1S6705 693-2715705 693-4394 Palser Enterprises,Ltd.1885 Blue Heron Dr.,#4,London,Ontario N6H 5L9519 471-9382519 471-1049 RAM Mechanical Marketing1301 Winnipeg St.,Regina,Saskatchewan S4R 1K2306 525-1986306 525-0809 RAM Mechanical Marketing510 Ave.M South,Saskatoon,Saskatchewan S7K 2K9306 244-6622306 244-0807 Walmar Mechanical Sales24 Gurdwara Rd.,Nepean,Ontario K2E 8B5613 225-9774613 225-0673 Fax # For Technical Assistance Call Your Authorized Ames Agent. Ca n a d a Telephone # So u t h Ce n t r a l 0426 No r t h Ea s t So u t h Ea s t Mi d At l a n t i c No r t h Ce n t r a l Wes t e r n Page 1 of 2 a company DOCUMENT #:REVISION: REG-ZW109 4/04 Model ZW109 Pressure Reducing Valve SPECIFICATION SUBMITTAL SHEET SIZES DIMENSIONS MATERIALS APPLICATION The Pressure Reducing Valve automatically reduces a higher inlet pressure to a steady lower downstream pres- sure regardless of changing flow rate and/or varying inlet pressure. This valve is an accurate, pilot-operated regula- tor capable of holding downstream pressure to a pre-de- termined limit. When downstream pressure exceeds the pressure setting of the control pilot, the main valve and pilot valve close drip tight. B (DIAMETER) C D G DD DDD B (DIAMETER) GGGE A H C AA F AAA FF GG OUTLET INLET K J OUTLET INLET J K H FEATURES ! Epoxy Coated, FDA approved ! Pilot Assembly "Flow clean strainer (sizes 1 1/4”-3”) "”Y” type strainer (sizes 4”-12”) "Opening speed control (sizes 1 1/4”-3”) "Isolation valve (size 4”-12”) MAIN VALVE OPTIONS ____Size ____Y-300lb. class flange (400psi max.) ____TH-Threaded ends (400 psi max.) ____KB-Viton rubber ____SS-Stainless Steel Seat ____AN-Angle body ____D-Check valve in Pilot Main Valve BodyDuctile Iron ASTM A536 Main Valve BonnetDuctile Iron ASTM A536 Disc GuideBronze ASTM B 62 SeatBronze ASTM B 62 DiscBuna-N Rubber DiaphragmNylon reinforced Buna-N StemStainless Steel SpringStainless Steel GLOBE:Threaded ends ! 1 1/4" thru 3” Flanged ends ! 1 1/2" thru 12” ANGLE:Threaded ends ! 1 1/2” thru 3” Flanged ends ! 1 1/2" thru 12” Ductile Iron ! 150 Class, 250 psi max. TEMPERATURE RATING: ! water33°F to 180°F PILOT SPRING RANGE:! 15-150 psi *1 1/2" size only 1 1/4-1 1/222 1/234681012 A Threaded7 1/49 3/81112 1/2----- AA 1508 1/2*9 3/81112152025 3/829 3/434 AAA 30091011 5/813 1/415 5/82126 3/831 1/835 1/2 BDiameter5 5/86 5/889 1/811 1/215 3/42023 5/828 CMax.5 1/26 1/27 9/168 3/1610 5/813 3/81617 1/820 7/8 D Threaded3 1/44 3/45 1/26 1/4----- DD 1504*4 3/45 1/267 1/21012 3/414 7/817 DDD 3004 1/4*55 7/86 3/87 7/810 1/213 1/415 9/1617 3/4 EALL1 1/81 1/21 11/162 1/163 3/164 5/165 5/169 1/410 3/4 F 1502 1/233 1/23 3/44 1/25 1/26 3/489 1/2 FF 3003 1/163 1/43 3/44 1/856 1/47 1/28 3/410 1/4 G Threaded1 7/83 1/444 1/2----- GG 1504*3 1/4445688 5/813 3/4 GGG 3004 1/4*3 1/24 5 /164 3/85 5/166 1/28 1/29 5/1614 1/2 H NPT Body Tapping 3/83/81/21/23/43/4111 J NPT Cover Center Plug 1/41/21/21/23/43/4111 1/4 K NPT Cover Tapping 3/83/81/21/23/43/4111 10-3210-3210-321/4-281/4-283/8-243/8-243/8-243/8-24 0.40.60.70.81.11.72.32.83.4 153550701402855007801165 VALVE SIZE inches Apprx. Ship Wt. Lbs. Valve Stem Internal Thread UNF Stem Travel DIMANSI CLASS Page 2 of 2 WILKINS OPERATION OF ZURN INDUSTRIES, 1747 Commerce Way, Paso Robles, CA 93446 Phone:805/238-7100 Fax:805/238-5766 IN CANADA: ZURN INDUSTRIES LIMITED, 3544 Nashua Dr., Mississauga, Ontario L4V 1L2 Phone:905/405-8272 Fax:905/405-1292 Product Support Help Line: 1-877-BACKFLOW (1-877-222-5356) • Website: http://www.zurn.com INLET PRESSURE GAUGE OUTLET PRESSURE GAUGE INLET SHUT-OFF OUTLET SHUT-OFF INLET SHUT-OFF OUTLET SHUT-OFF DIRECTION OF FLOW PILOT SYSTEM DIMENSIONS FLOW CHARACTERISTICS SPECIFICATIONS Suggested flow calculations are based on flow through Schedule 40 Pipe. Maximum continuous flow is approx. 20 ft./sec (6.1 meters/sec) & maximum intermittent is approx. 25 ft./sec (7.6 meters/sec) and mini- mum continuous flow is approx. 1 ft./ sec (0.3 meters/sec). Many factors should be considered in sizing pres- sure reducing valves including inlet pressure, outlet pressure and flow rates. Y Z X Y Z X INLET GLOBE INLET ANGLE inches1 1/41 1/222 1/234681012 mm3240506580100150200250300 11.511.512.512.751313.2515.7517.2520.2521.75 4444.556810.251214.25 6.56.56.57899.511.512.514.5 Valve Size Z Max. (inches) X Max. (inches) Y Max. (inches) The Model ZW109 utilizes a pressure reducing pilot valve that installs on the discharge side of the control circuitry. The pilot is a direct acting, normally open, spring loaded, diaphragm actuated valve; the spring being adjustable within a 10:1 ratio. The operation of the ZW109 begins with accurately sizing the valve, then fine tuning the control circuit by adjusting the pilot spring to the desired downstream pressure. Inlet pressure is piped to the inlet port of the pressure reducing pilot. A sensing line runs internally from the discharge side of the pilot to its lower control chamber under the diaphragm. Thus, downstream pressure exceeding the preset acts to close the pilot while the adjustable spring seeks to keep it open. The result is a modulating action in the pilot that is transmitted to the bonnet of the main valve. This creates a mirror modulation of the diaphragm assembly in the main valve. Downstream pressure is maintained within narrow limits regardless of changing flow rates or varying inlet pressures. The Pressure Reducing Valve shall be a single seated, line pressure operated, diaphragm actuated, pilot controlled, globe or angle valve. The valve shall seal by means of a corrosion-resistant seat and resilient, rectangular seat disc. These and other parts shall be replaceable in the field; all such service and adjustments to be possible without removing the valve from the line. The main valve body shall be ductile iron ASTM A 536. The stem of the basic valve shall be guided top and bottom by integral bushings. The basic valve and its pilot control system shall contain no packing glands or stuffing boxes. The diaphragm shall not be used as a seating surface nor shall pistons be used as an operating medium. All internal and external ferrous surfaces shall be coated with a high quality, fusion epoxy coating. The pilot control system shall consist of a two-way, normally open, direct acting, adjustable spring loaded, diaphragm actuated pressure reducing pilot. The pilot control shall be field adjustable from 15 psi to 150 psi; adjustment range not to exceed a 10:1 ratio. The Pressure Reducing Valve shall be a WILKINS Model ZW109. TYPICAL INSTALLATION OPERATION inches1 1/41 1/222 1/234681012 mm3240506580100150200250300 Max. Continuous931252103004608001800310049007000 Max. Intermittent1201602603705809902250390061508720 Min. Continuous101015203050115200300400 Max. Continuous6813192950113195309441 Max. Intermittent7.610.116.4233762142246387549 Min. Continuous0.60.60.91.31.93.27.2131925 Suggested Flow (Liters/sec) Valve Size Suggested Flow (GPM) JOB NAMECONTRACTOR JOB LOCATIONENGINEER Full Line Sch-40 Replacement Dyna-Thread® – M-COAT® sprinkler pipe represents an engineering advancement for the sprinkler pipe industry. It combines the safety and longevity of traditional Sch-40 pipe with quality and superior hydraulic advantages. Comparison to Schedule 40 Dyna-Thread – M-COATs inside diameter is up to 3.6% larger than Sch-40 giving it superior hydraulics. Also, when used in combination with Dyna-Flow – M-COAT pipe, down sizing often occurs. Dyna-Thread – M-COAT is fully listed and approved UL, ULC, and FM for fire sprinkler applications. The life expectancy of Dyna-Thread – M-COAT and Sch-40 are equal based on the calculated wall thicknesses per UL. The consistent quality of steel used to make Dyna-Thread – M-COAT facilitates smooth threading and lower maintenance costs. The exterior of Dyna-Thread – M-COAT is protected by a clean, durable mill coating for extended shelf life and easy paint application. With its increased strength and lighter weight, Dyna-Thread – M-COAT reduces installation fatigue and is ideal for retro-fit applications. Corrosion Resistance Ratio (CRR) is a UL (Underwriters Laboratory) term for the estimated life expectancy of a pipe joint. This is based on the calculated wall thickness at the base of the first exposed thread, assumed to be the weakest point of the pipe length. Dyna-Thread – M-COAT and Sch-40 have the same calculated wall thicknesses at this point and are both assigned the same CRR of 1.00. Comparison to L.W.T. Pipe More wall thickness at the thread (CRR=1.00) gives Dyna-Thread – M-COAT better life expectancy than lightwall threadable pipe joints. Dyna-Thread – M-COAT is approved for standard hanger spacing (15 ft. O.C.), can be used as earthquake sway bracing, and is safe to use as drops. Dyna-Thread – M-COAT is safer to weld on than many zinc coated lightwall threadable pipe products. Dyna-Thread – M-COAT is more widely accepted than lightwall threadable where Sch-40 is specified. American Made Able to meet “Buy American” requirements, and is available through distributors in the USA, Canada, Mexico and Latin America. Specifications & Approvals Dyna-Thread – M-COAT pipe is manufactured to meet: ASTM A 135, Type E Grade A, and is in compliance with NFPA-13. All sizes of Dyna-Thread – M-COAT are rated at 300 psi working pressure. Dyna-Thread – M-COAT is UL and ULC Listed for wet, dry and pre-action sprinkler systems and FM Approved for use in wet systems. Dyna-Thread – M-COAT can be “hot- dip” galvanized* to meet FM requirement for dry systems. Dyna-Thread – M-COAT is approved for all threaded couplings and welded outlets and is suitable for all roll-grooved, and plain-end fittings. (See listing information). Dyna-Thread® – M-COAT ® Submittal Data Sheet Customer Service (800) 882-5543 Fax: (800) 659-7730 www.alliedtube-sprinkler.com • 16100 S Lathrop Ave. • 11350 Norcom Rd. • 2525 N 27th Ave. • 600 Dean Sievers Place Harvey, IL 60426 Philadelphia, PA 19154 Phoenix, AZ 85009 Morrisville, PA 19067 ©2011 Atkore International, Inc. All Rights Reserved. STP-S3-4M-1105 Project: Sprinkler Contractor: Date: Engineer: Specification Reference: System Type: Locations: Comments: Dyna-Thread – M-COAT Specifications NPSNominal I.D.Wt.Wt. (H20 Filled)CRRCRR In; mmIn; mmLbs/Ft; kg/mLbs/Ft; kg/m UnthreadedThreaded 1”1.0801.3301.7511.391.00 2527.42.02.60–– 1¼”1.4081.8702.549.501.00 3235.82.83.78–– 1½”1.6392.2903.229.141.00 4041.63.44.79–– 2”2.1043.0504.578.411.00 5053.44.56.80–– * Must be ordered in 10 bundle increments. Specifications & Approvals Dyna-Flow – M-COAT pipe is manufactured to meet ASTM A-795 Type E, Grade A and is in compliance with NFPA-13 and NFPA- 14. All sizes of Dyna-Flow – M-COAT are UL and cUL listed and FM approved. Dyna-Flow – M-COAT is UL and cUL listed for use with roll grooved, plain-end and welded joints for wet, dry, pre-action and deluge systems. It is FM approved for roll grooved, plain end and welded joints for wet systems. Dyna-Flow – M-COAT is available “hot-dip” galvanized** and has been specifically approved by FM for dry system uses. Dyna-Flow – M-COAT complies with NFPA 13 and is rated at 300 psi working pressure. Superior Coating Dyna-Flow – M-COAT products are coated with an environmentally approved and specially formulated modified-acrylic or water-based coating. This durable coating is paintable and acts as an excellent primer while resisting weather and UV degradation from outdoor storage. The internal surface of all black Allied Tube & Conduit fire sprinkler pipe products are coated with M-COAT, an advanced MIC coating that is FBC™ system compatible for hybrid sprinkle systems. FBC system compatible indicates that this product has been tested, and is monitored on an ongoing basis, for chemical compatibility with FlowGuard Gold®, BlazeMaster®, and Corzan® pipe and fittings.* American Made Able to meet “Buy American” requirements, and is available through distributors in the USA, Canada, Mexico and Latin America. Dyna-Flow Specifications NPSNominal I.D.Wt.Wt. (H20 Filled)CRR In; mmIn; mmLbs/Ft; kg/mLbs/Ft; kg/m Unthreaded 1”1.1910.8301.312.41 2530.31.21.95– 1¼”1.5361.0591.871.55 3239.01.62.78– 1½”1.7281.6672.713.44 4043.92.54.03– 2”2.2032.1043.792.78 5056.03.15.64– 2½”2.7032.5645.101.60 6568.73.87.59– 3”3.3143.3877.181.48 7584.25.010.69– 4”4.3104.47310.861.00 100109.56.716.16– Dyna-Flow® – M-COAT ® High Strength Steel Pipe Customer Service (800) 882-5543 Fax: (800) 659-7730 www.alliedtube-sprinkler.com • 16100 S Lathrop Ave. • 11350 Norcom Rd. • 2525 N 27th Ave. • 600 Dean Sievers Place Harvey, IL 60426 Philadelphia, PA 19154 Phoenix, AZ 85009 Morrisville, PA 19067 ©2011 Atkore International, Inc. All Rights Reserved. STP-S2-3M-1105 • Exceptional hydraulics • Lightweight and easy to install • Available factory roll grooved • M-COAT ID • UL and cUL listed • FM approved The original high-strength light wall sprinkler pipe with superior hydraulics. Dyna-Flow® – M-COAT® is the “original” high-strength light wall sprinkler pipe. With outstanding hydraulic capabilities, Dyna-Flow – M-COAT is recognized as the most popular alternative to Schedule-10 pipe. Lightweight and easy to cut , Dyna-Flow – M-COAT is a valuable addition to any fire protection system. With an inside diameter (ID) up to 11% larger than Schedule-40 and up to 7% larger than Schedule -10, Dyna-Flow – M-COAT pipe hydraulics are exceptional. Larger ID’s enable Dyna-Flow – M-COAT and related components to be down-sized within the system, increasing the potential for job cost savings. For complete Hazen Williams charts, refer to “Dyna-Flow – M-COAT Hydraulic Data Tables”. Dyna-Flow – M-COAT pipe has metallurgical properties that provide excellent fabrication characteristics for end prep finishes, welding and roll grooving. There are no special processes or equipment needed for fabrication and installation. * FBC™, FlowGuard Gold®, BlazeMaster®, and Corzan® are licensed trademarks of The Lubrizol Corporation ** Must be ordered in 10 bundle increments The Style 750 Reducing Coupling permits direct reduction on the piping run. Designed to replace two couplings and a reducing fitting, the Style 750 features a special reducing gasket for pressure responsive sealing. A steel washer which prevents telescoping of the smaller pipe inside the larger pipe during vertical systems assembly is available upon request. Housing: Ductile iron conforming to ASTM A-536, grade 65-45-12. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Housing Coating: Orange enamel • Optional: Hot dipped galvanized and others Gasket: (Specify choice*): • Grade “E” EPDM (All other sizes) EPDM (Green color code). Temperature range –30°F to +230°F/–34°C to +110°C. Recommended for cold and hot water service within the specified temperature range plus a variety of dilute acids, oil-free air and many chemical services. UL classified in accordance with ANSI/NSF 61 for cold +86°F/+30°C and hot +180°F/+82°C potable water service. NOT RECOMMENDED FOR PETROLEUM SERVICES. • Grade “T” nitrile Nitrile (Orange color code). Temperature range –20°F to +180°F/–29°C to +82°C. Recommended for petroleum products, air with oil vapors, vegetable and mineral oils within the specified temperature range. Not recommended for hot water services over +150°F/+66°C or for hot dry air over +140°F/+60°C. * Services listed are General Service Recommendations only. It should be noted that there are services for which these gaskets are not recommended. Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service recommendations and for a listing of services which are not recommended. • Optional: Assembly Washer: Galvanized, carbon steel Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. MATERIAL SPECIFICATIONS 06.08_1 Reducing Coupling STYLE 750 06.08CARBON STEEL PIPE – GROOVED COUPLINGS JOB/OWNER CONTRACTOR ENGINEER System No. __________________________Submitted By ________________________Spec Sect ____________ Para __________ Location ____________________________Date ________________________________Approved ___________________________ Date ________________________________ www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2007 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. REV_I Exaggerated for clarity SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS VNIIPO DIMENSIONS X ZY X ZY Size Max. Work Pressure *Max. End Load * Allow. Pipe End Sep. †Deflect. Fr. CL† Bolt/Nut@ No - Size Dimensions – Inches/mm Approx. Wgt. Each Nominal Size Inches/mm psi kPa Lbs. N Inches/ mm Per Cplg. Deg. Pipe In./Ft. mm/m Inches X Y Z Lbs. kg 2 × 1 350 500 0 – 0.07 0˚ – 57'0.20 2 – 3/8 x 2 3.38 5.28 1.88 2.7 50 25 2410 2225 0 – 1.8 17 85 134 48 1.2 1 1/2 350 1000 0 – 0.07 0˚ – 57'0.20 2 – 3/8 x 2 3.38 5.28 1.88 2.0 40 2410 4450 0 – 1.8 17 85 134 48 1.0 2 1/2 × 2 500 2215 0 – 0.07 0˚ – 47'0.16 2 – 3/8 x 2 4.00 5.93 1.88 3.1 65 50 3450 9850 0 – 1.8 14 102 151 48 1.4 76.1 mm × 2 350 1550 0 – 0.07 0˚ – 47'0.16 2 – 1/2 x 2 3/4 4.38 6.63 1.88 4.6 50 2410 6900 0 – 1.8 14 111 168 48 2.1 3 × 2 350 1550 0 – 0.07 0˚ – 39'0.13 2 – 1/2 x 2 3/4 4.75 7.13 1.88 4.9 80 50 2410 6900 0 – 1.8 11 121 181 48 2.2 2 1/2 500 3250 0 – 0.07 0˚ – 39'0.13 2 – 1/2 x 2 3/4 4.75 7.13 1.88 4.3 65 3450 14460 0 – 1.8 11 121 181 48 2.0 88.9 mm × 76.1 mm 350 2275 0 – 0.07 0˚ – 39'0.13 2 – 1/2 x 2 3/4 4.75 7.13 1.88 4.2 2410 10125 0 – 1.8 11 121 181 48 1.9 4 × 2 350 1550 0 – 0.13 1˚ – 19'0.28 2 – 5/8 x 3 1/4 6.25 8.90 2.25 8.1 100 50 2410 6900 0 – 3.2 25 159 226 57 3.7 2 1/2 350 2275 0 – 0.13 1˚ – 19'0.28 2 – 5/8 x 3 1/4 6.25 8.90 2.25 8.6 65 2410 10125 0 – 3.2 25 159 226 57 3.9 3 500 4810 0 – 0.13 1˚ – 19'0.28 2 – 5/8 x 3 1/4 6.00 8.90 2.25 6.7 80 3450 21400 0 – 3.2 25 152 226 57 3.0 114.3 mm × 76.1 mm 350 2475 0 – 0.13 1˚ – 19'0.28 2 – 5/8 x 3 1/4 6.25 8.90 2.25 6.9 2410 11014 0 – 3.2 25 159 226 57 3.1 5 × 4 350 5565 0 – 0.13 1˚ – 3'0.22 2 – 3/4 x 4 1/4 7.18 10.70 2.13 11.2 125 100 2410 24765 0 – 3.2 19 182 272 54 5.1 6 × 4 350 5565 0 – 0.13 0˚ – 52'0.18 2 – 3/4 x 4 1/4 8.63 11.90 2.25 16.7 150 100 2410 24765 0 – 3.2 15 181 302 57 7.6 5 350 8500 0 – 0.13 0˚ – 52'0.18 2 – 3/4 x 4 1/4 8.31 11.90 2.25 12.9 125 2410 37825 0 – 3.2 15 211 302 57 5.9 165.1 mm × 4 350 5565 0 – 0.13 0˚ – 55'0.19 2 – 3/4 x 4 1/4 8.63 11.90 2.25 15.2 100 2410 24765 0 – 3.2 16 219 302 57 6.9 8 × 6 350 12000 0 – 0.13 0˚ – 38'0.13 2 – 7/8 x 5 10.81 14.88 2.50 22.4 200 150 2410 53400 0 – 3.2 11 275 378 64 10.2 219.1 mm × 165.1 mm 350 1625 0 – 0.13 0˚ – 38'0.13 2 – 7/8 x 5 10.75 14.88 2.50 23.2 2410 0 – 3.2 11 273 378 64 10.5 10 × 8 350 20450 0 – 0.13 0° – 25'0.9 2 – 1 x 5 1/2 13.12 17.26 2.62 31.4 273 219.1 2410 0 – 3.2 8 333 438 67 14.2 Style 750 Reducing couplings should not be used with end caps (#60) in systems where a vacuum may be developed. Contact Victaulic for details. * Working Pressure and End Load are total, from all internal and external loads, based on standard weight (ANSI) steel pipe, standard roll or cut grooved in accordance with Victaulic specifications. Contact Victaulic for performance on other pipe. Maximum working pressure rating based on larger pipe size. Maximum End Load rating based on smaller pipe size. WARNING: FOR ONE TIME FIELD TEST ONLY, the Maximum Joint Working Pressure may be increased to 1 1/2 times the figures shown. † Allowable Pipe End Separation and Deflection figures show the maximum nominal range of movement available at each joint for standard roll grooved pipe. Figures for standard cut grooved pipe may be doubled. These figures are maximums; for design and installation purposes these figures should be reduced by: 50% for 3/4 – 3 1/2"/20 – 90 mm; 25% for 4"/100 mm and larger. @ Number of bolts required equals number of housing segments. Metric thread size bolts are available (color coded gold) for all coupling sizes upon request. Contact Victaulic for details. WARNING: Depressurize and drain the piping system before attempting to install, remove, or adjust any Victaulic piping products. 06.08_2 Reducing Coupling STYLE 750 06.08CARBON STEEL PIPE – GROOVED COUPLINGS www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2007 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. REV_I FLOW DATA Size Equiv. Pipe Length Nominal Size Inches/mm Sm. Dia. Feet/m 2 × 1 5.9 50 25 1.8 1 1/2 2.0 40 0.6 2 1/2 × 2 1.9 65 50 0.6 76.1 mm × 2 1.9 50 0.6 3 × 2 5.5 80 50 1.7 2 1/2 3.8 65 1.2 88.9 mm × 76.1 mm 3.8 1.2 4 × 2 6.0 100 50 1.8 2 1/2 6.0 65 1.8 3 6.0 80 1.8 114.3 mm × 76.1 mm 6.0 1.8 5 × 4 3.0 125 100 0.9 6 × 4 6.0 150 100 1.8 5 4.5 125 1.4 165.1 mm × 4 6.0 100 1.8 8 × 6 7.3 200 150 2.2 219.1 mm × 165.1 mm 7.3 2.23 10 × 8 8.7 273 219.1 2.65 Size Equiv. Pipe Length Nominal Size Inches/mm Sm. Dia. Feet/m 1 × 2 2.7 25 50 0.8 1 1/2 × 2 1.9 40 50 0.6 2 × 2 1/2 1.0 50 65 0.3 76.1 mm 1.0 0.3 3 3.5 80 1.1 4 3.0 100 0.9 2 1/2 × 3 2.5 65 80 0.8 4 3.0 100 0.9 76.1 mm × 88.9 mm 2.5 0.8 114.3 mm 3.0 0.9 3 × 4 2.5 80 100 0.8 4 × 5 3.3 100 125 1.0 6 4.6 150 1.4 165.1 mm 4.6 1.4 5 × 6 2.3 125 150 0.7 6 × 8 6.0 150 200 1.8 165.1 mm × 219.1 mm 5.4 1.65 8 × 10 6.3 219.1 273 19.2 HEAD LOSS The head loss across Style 750 Reducing coupling is very small and is essentially the same as for standard short body reducing pipe fittings. Equivalent lengths of standard weight steel pipe are shown in the tables. All data is based on water flowing at ambient temperature. FLOW REDUCING FLOW EXPANDING 06.08_3 Reducing Coupling STYLE 750 06.08CARBON STEEL PIPE – GROOVED COUPLINGS www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2007 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. REV_I WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. NOTE Reference should always be made to the I-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. INSTALLATION WCAS-6UPKD7 06.08 Reducing Coupling STYLE 750 CARBON STEEL PIPE – GROOVED COUPLINGS 06.08 For complete contact information, visit www.victaulic.com 06.08 1536 REV I UPDATED 6/2008 VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2007 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. IPS CARBON STEEL PIPE – FIRE PROTECTION PRODUCTS VICTAULIC ® IS AN ISO 9001 CERTIFIED COMPANY ® REGISTERED TRADEMARK OF VICTAULIC – © COPYRIGHT 2006 VICTAULIC – PRINTED IN U.S.A. – SKU #WCAS-67PJUX 1539 REV F 10.03 United States • Phone: 1-800-PICK-VIC (1-800-742-5842) • Fax: 610-250-8817 • e-mail: pickvic@victaulic.com Canada • Phone: 905-884-7444 • Fax: 905-884-9774 • e-mail: viccanada@victaulic.com Europe • Phone: 32-9-381-1500 • Fax: 32-9-380-4438 • e-mail: viceuro@victaulic.be UK • Phone: 44(0)1438741100 • Fax: 44(0)1438313883 • e-mail: viceuro@victaulic.be Central and South America • Phone: 610-559-3300 • Fax: 610-559-3608 • e-mail: vical@victaulic.com Australasia • Phone: 86-21-54253300 • Fax: 86-21-54253671 • e-mail: vicap@victaulic.com FireLock ® Fittings PRODUCT DESCRIPTION FireLock ® products comprise a unique system specifically designed for fire protection services. FireLock full-flow elbows and tees are a CAD-developed, hydrodynamic design that has a shorter center-to-end dimension than standard fittings. A noticeable bulge allows the water to make a smoother turn to maintain similar flow characteristics as standard full flow fittings. FireLock fittings are designed for use exclusively with Style 005 and Style 009 FireLock couplings. Use of other couplings or flange adapters may result in bolt pad interference. Victaulic FireLock fittings pressure ratings conform to the ratings of Victaulic FireLock Style 005 couplings. DIMENSIONS T C to E C to E C to E No. 001No. 003 No. 002No. 006 C to E C to E Fitting Size No. 001 90° Elbow No. 003 45° Elbow No. 002 Straight Tee No. 006 Cap Nominal Diameter Inches/mm Actual Outside Diameter Inches/mm C to E Inches mm Aprx. Weight Each Lbs./kg C to E Inches mm Aprx. Weight Each Lbs./kg C to E Inches mm Aprx. Weight Each Lbs./kg Thickness “T” Inches mm Aprx. Weight Each Lbs./kg 1 1 / 4 1.660 ––––––0.820.3 3242.4 ––––––210.1 1 1 / 2 1.9002.751.21.750.92.752.00.820.4 4048.3700.5454.1700.9210.2 22.3752.751.72.001.82.752.40.880.6 5060.3700.8510.8701.1220.3 2 1 / 2 2.8753.003.12.252.23.003.60.881.0 6573.0761.4571.0761.6220.5 76.1 mm 3.0003.003.302.252.4–––– 76.1761.5571.1–––– 33.5003.384.02.503.13.385.30.881.2 8088.9861.8641.4862.4220.5 108 mm 4.2504.005.73.005.14.007.5–– 108.01022.6762.31023.4–– 44.5004.006.73.005.64.008.71.002.4 100114.31023.0762.51023.9251.1 55.5634.8812.63.258.34.8815.71.004.1 125141.31245.7833.81247.1251.9 159 mm 6.2505.5012.63.509.23.5017.9–– 158.81405.7894.21408.0–– 66.6255.5018.33.5011.75.5022.71.005.9 150168.31408.3895.314010.3252.7 88.6256.8125.54.2520.46.9438.71.1312.7 200219.117311.61089.317617.6295.8 ULCUL® FM See Victaulic publication 10.01 for details. Patented 2 FireLock ® Fittings 10.03 FLOW DATA MATERIAL SPECIFICATIONS Fitting: Ductile iron conforming to ASTM A-536, grade 65-45-12 Fitting Coating: Orange enamel • Optional: Hot dipped galvanized Fitting Size Frictional Resistance Equivalent Feet/meters of Straight Pipe Nominal Diameter Inches/mm Actual Outside Diameter Inches/mm 90° Elbow No. 001 45° Elbow No. 003 Straight Tee No. 002 BranchRun 1 1 / 4 1.6601.50.83.71.5 3242.40.50.21.10.5 1 1 / 2 1.9002.21.15.52.2 4048.30.70.31.70.7 22.3753.51.88.53.5 5060.31.10.52.61.1 2 1 / 2 2.8754.32.210.84.3 6573.01.30.73.31.3 76.1 mm 3.0004.52.311.04.5 76.11.40.73.41.4 33.5005.02.613.05.0 8088.91.50.84.01.5 108 mm 4.2506.43.215.36.4 108.02.00.94.72.0 44.5006.83.416.06.8 100114.32.11.04.92.1 55.5638.54.221.08.5 125141.32.61.36.42.6 159 mm 6.2509.44.925.09.6 158.82.91.57.62.9 66.62510.05.025.010.0 150168.33.01.57.63.0 88.62513.05.033.013.0 200219.14.01.510.14.0 † The flow data listed is based upon the pressure drop of Schedule 40 pipe. This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. R IPS CARBON STEEL PIPE – FIRE PROTECTION FITTINGS VICTAULIC ® IS AN ISO 9001 CERTIFIED COMPANY ® REGISTERED TRADEMARK OF VICTAULIC – © COPYRIGHT 2004 VICTAULIC – PRINTED IN U.S.A.1509 REV D 10.05 Victaulic Company of America • Phone: 1-800-PICK-VIC (1-800-742-5842) • Fax: 610-250-8817 • e-mail:pickvic@victaulic.com Victaulic Company of Canada • Phone: 905-884-7444 • Fax: 905-884-9774 • e-mail: viccanada@victaulic.com Victaulic Europe • Phone:32-9-381-1500 • Fax: 32-9-380-4438 • e-mail: viceuro@victaulic.be Victaulic America Latina • Phone: 610-559-3300 • Fax: 610-559-3608 • e-mail: vical@victaulic.com Victaulic Asia Pacific • Phone: 65-6235-3035 • Fax: 65-6235-0535 • e-mail: vicap@victaulic.com No. 10-DR Drain Elbow PRODUCT DESCRIPTION No. 10-DR drain elbows are specifically designed for use on fire protection standpipes. The drain is drilled and tapped for a 1" (25 mm) NPT outlet. Constructed of durable ductile iron all sizes conform to the ratings of Style 77 couplings. No.10-DR elbows are supplied with grooves or shoulders. These fittings are not intended for use with Victaulic Plain End couplings. When connecting wafer or lug-type butterfly valves directly to Victaulic drain elbows with Style 741 or 743 Vic-Flange ® adapters or Style 744 FireLock ® Flange adapters, check disc clearance dimensions with the I.D. dimension of the fitting. DIMENSIONS MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A-536, grade 65-45-12. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Fitting Coatings: Orange enamel • Optional: Hot dip galvanized and others. ULCUL® FM See Victaulic publication 10.01 for details. USA C to E H C to E P Fitting Size Dimensions Inches/millimeters Approximate Weight Each Lbs./kg Nominal Outside Diameter Inches/mm Actual Outside Diameter Inches/mmC - EHP 2 1 / 2 2.8753.752.751.685.2 6573,09570432,4 3 3.5004.252.752.105.3 8088,910870532,4 4 4.5005.002.752.608.8 100114,312770664,0 6 6.6256.502.753.6518.7 150168,316570938,5 This product shall be manufactured by Victaulic Company. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. Victaulic Mechanical-T® Outlet provides a direct branch connection at any location a hole can be cut in pipe. The hole is cut oversize to receive a “holefinder” locating collar which secures the outlet in position permanently. A pressure responsive gasket seals on the pipe O.D. Cross-type connections can be achieved by utilizing two upper housings of the same style and size, with the same or differing branch size connections. NOTE: Style 920 and Style 920N housings cannot be mated to each other to achieve a cross connection. Style 920 and Style 920N Mechanical-T outlets are available with grooved or female threaded outlet. Specify choice on order. Units are supplied painted with plated bolts. Galvanized hous- ings are available, supplied with plated bolts. All sizes of Style 920 and 920N are rated at 500 psi/3450 kPa working pressure on Schedule 10 and 40 carbon steel pipe. They may also be used on high density polyethylene or poly- butylene (HDPE) pipe. Pressure ratings on HDPE are dependent on the pipe rating. Contact Victaulic for ratings on other pipe. Style 920 and 920N are not recommended for use on PVC plastic pipe. Standard piping practices dictate that the Mechanical-T Styles 920 and 920N must be installed so that the main and branch connections are a true 90° angle when permanently attached to the pipeline surface. Additionally, the Vic-Tap II® hole cutting tool, which allows for hole cutting capabilities on pressurized systems, utilizes the Style 920 Mechanical-T in conjunction with the Series 726 Vic-Ball Valve to create the Style 931 Vic-Tap II Mechanical-T unit. See page 8 for further information. MATERIAL SPECIFICATIONS Housing/Coating: Ductile iron conforming to ASTM A-536, grade 65-45-12, with orange enamel coating. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. • Optional: Hot dipped galvanized Gasket: (Specify choice*) • Grade “E” EPDM EPDM (Green color code). Temperature range –30°F to +230°F/–34°C to +110°C. Recommended for cold and hot water service within the specified temperature range plus a variety of dilute acids, oil-free air and many chemical services. UL Classified in accordance with ANSI/NSF 61 for cold +86°F/+30°C and hot +180°F/+82°C. NOT RECOMMENDED FOR PETROLEUM SERVICES. • Grade “T” nitrile Nitrile (Orange color code). Temperature range –20°F to +180°F/–29°C to +82°C. Recommended for petroleum products, air with oil vapors, vegetable and mineral oils within the specified temperature range. Not recommended for hot water services over +150°F/+66°C or for hot dry air over +140°F/+60°C. *Services listed are General Service Recommendations only. It should be noted that there are services for which these gaskets are not recommended. Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service recommendations and for a listing of services which are not recommended. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. 11.02_1 Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N PATENTED 11.02IPS CARBON STEEL PIPE - HOLE CUT PRODUCTS JOB/OWNER CONTRACTOR ENGINEER System No. __________________________Submitted By ________________________Spec Sect ____________ Para __________ Location ____________________________Date ________________________________Approved ___________________________ Date ________________________________ www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2007 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. REV_J STYLES 920 AND 920N STYLE 920 CROSS SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS DIMENSIONS GROOVED OUTLET W ZY V Size Style No. Max. Work Pressure Dimensions Approx. Weight Each Run × Branch Nominal Size Inches mm 920 or 920N psi kPa Hole Diameter +0.13 -0.00 T** Inches mm V ‡ # Thd. Inches mm V ‡ Grv. Inches mm W Inches mm Y Inches mm Z Inches mm Female Thd. Lbs. kg Grv. Lbs. kg 2 × 1/2 (a)920N 500 1.50 2.00 2.53 —1.61 5.35 2.75 3.1 —50 15 3450 38.1 51 64 41 136 70 1.5 3/4 (a)920N 500 1.50 1.97 2.53 —1.61 5.35 2.75 3.1 —20 3450 38.1 50 64 41 136 70 1.5 1 (a)920N 500 1.50 1.85 2.53 —1.61 5.35 2.75 3.0 —25 3450 38.1 47 64 41 136 70 1.4 1 1/4 (a) †920N 500 1.75 2.05 2.75 3.00 1.61 5.35 3.00 3.5 3.2 32 3450 44.5 52 70 76 41 136 76 1.7 1.5 1 1/2 (a) †920N 500 1.75 2.03 2.75 3.12 1.61 5.35 3.25 3.6 3.2 40 3450 44.5 52 70 79 41 136 83 1.7 1.5 2 1/2 × 1/2 (a)920N 500 1.50 2.21 2.74 —91.82 5.64 2.75 3.0 —65 15 3450 38.1 56 70 46 143 70 1.4 3/4 (a)920N 500 1.50 2.18 2.74 —1.82 5.64 2.75 3.0 —20 3450 38.1 55 70 46 143 70 1.4 1 (a)920N 500 1.50 2.06 2.74 —1.82 5.64 2.75 2.9 —25 3450 38.1 52 70 46 143 70 1.4 1 1/4 † (a)920N 500 1.75 2.30 3.00 3.25 1.82 6.29 3.00 3.5 3.2 32 3450 44.5 58 76 83 46 160 76 1.7 1.5 1 1/2 † (a)920N 500 2.00 2.28 3.00 3.25 1.82 6.26 3.25 3.6 3.3 40 3450 50.8 58 76 83 46 159 83 1.7 1.6 76.1 × 1/2 (a)920 300 1.50 2.22 2.75 —2.25 6.46 3.18 3.9 —15 2065 38.1 56 70 57 164 81 1.8 3/4 (a)920 300 1.50 2.19 2.75 —2.25 6.46 3.18 3.9 —20 2065 38.1 56 70 57 164 81 1.8 1 (a)920 300 1.50 2.07 2.75 —2.25 6.46 3.18 3.8 —25 2065 38.1 53 70 57 164 81 1.7 1 1/4 (a)920 500 1.75 2.30 3.00 3.31 1.92 6.29 3.00 3.5 3.2 32 3450 44.5 58 76 84 49 160 76 1.6 1.5 1 1/2 (a)920 500 2.00 2.28 3.00 3.31 1.92 6.29 3.25 3.5 3.3 40 3450 50.8 58 76 84 49 160 83 1.6 1.5 3 × 1/2 (a)920N 500 1.50 2.52 3.05 —2.28 6.15 2.75 3.4 —80 15 3450 38.1 64 78 58 156 70 1.6 3/4 (a)920N 500 1.50 2.49 3.05 —2.28 6.15 2.75 3.4 —20 3450 38.1 63 78 58 156 70 1.6 1 (a)920N 500 1.50 2.38 3.06 —2.28 6.15 2.75 3.3 —25 3450 38.1 61 78 58 156 70 1.6 1 1/4 (a) †)920N 500 1.75 2.55 3.25 3.56 2.28 6.15 3.00 3.8 3.7 32 (b 3450 44.5 65 83 90 58 156 76 1.8 1.8 1 1/2 (a) †920N 500 2.00 2.78 3.50 3.56 2.28 6.15 3.25 4.1 3.8 40 (b)3450 50.8 71 89 90 58 156 83 1.9 1.8 2 (a)920N 500 2.50 2.75 3.50 3.56 2.28 6.75 3.88 4.9 4.6 50 3450 63.5 70 89 90 58 172 99 2.3 2.1 3 1/2 × 2 920N 500 2.50 ——3.75 2.44 6.72 3.88 —3.8 90 50 3450 63.5 95 62 171 99 1.8 TABLE CONTINUED ON PG. 3 FEMALE THREADED OUTLET T W ZY V Important notes: Style 920 and Style 920N housings cannot be mated to one another to achieve cross connections. • Provides a direct branch connection at any location where a hole can be cut in the pipe • A pressure responsive gasket provides the seal • Request Publication 11.03 for Mechanical-T cross assemblies • Pressure rated up to 500 psi/3450 kPa on steel pipe; also available for use with HDPE pipe • Sizes from 2 × ½"/50 × 15 mm through 8 × 4"/200 × 100 mm 11.02_2 Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N 11.02IPS CARBON STEEL PIPE - HOLE CUT PRODUCTS www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2007 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. REV_J DIMENSIONS GROOVED OUTLET W ZY V FEMALE THREADED OUTLET T W ZY V Important notes: Style 920 and Style 920N housings cannot be mated to one another to achieve cross connections. • Provides a direct branch connection at any location where a hole can be cut in the pipe • A pressure responsive gasket provides the seal • Request Publication 11.03 for Mechanical-T cross assemblies • Pressure rated up to 500 psi/3450 kPa on steel pipe; also available for use with HDPE pipe • Sizes from 2 × ½"/50 × 15 mm through 8 × 4"/200 × 100 mm Size Style No. Max. Work Pressure Dimensions Approx. Weight Each Run × Branch Nominal Size Inches mm 920 or 920N psi kPa Hole Diameter +0.13 -0.00 T** Inches mm V ‡ # Thd. Inches mm V ‡ Grv. Inches mm W Inches mm Y Inches mm Z Inches mm Female Thd. Lbs. kg Grv. Lbs. kg TABLE CONTINUED FROM PAGE 2 4 × 1/2 (a)920N 500 1.50 3.03 3.56 —2.69 7.01 2.75 3.7 —100 15 3450 38.1 77 90 68 178 70 1.8 3/4 (a)920N 500 1.50 3.00 3.56 —2.69 7.01 2.75 3.7 —20 3450 38.1 76 90 68 178 70 1.8 1 (a)920N 500 1.50 2.88 3.56 —2.69 7.01 2.75 3.6 —25 3450 38.1 73 90 68 178 70 1.8 1 1/4 (a) †920N 500 1.75 3.08 3.78 4.00 2.69 7.01 3.00 4.0 3.6 32 (b)3450 44.5 78 96 102 68 178 76 1.9 1.8 1 1/2 (a) †920N 500 2.00 3.28 4.00 4.00 2.69 7.01 3.25 4.2 3.9 40 (b)3450 50.8 83 102 102 68 178 83 2.0 1.9 2 (a) †920N 500 2.50 3.25 4.00 4.00 2.69 7.01 3.88 5.0 4.6 50 3450 63.5 83 102 102 68 178 99 2.3 2.1 2 1/2 (a) †920 500 2.75 2.88 4.00 4.00 2.69 7.34 4.63 5.8 5.0 65 3450 69.9 73 102 102 68 186 118 2.6 2.3 76.1 mm 920 500 2.75 ——4.00 2.69 7.34 4.63 —6.4 3450 69.9 102 68 186 118 2.9 3 (a) †920 500 3.50 3.31 4.50 4.12 2.69 7.73 5.12 8.4 6.4 80 3450 88.9 84 114 105 68 196 130 3.8 2.9 108.0 × 1 1/4 (a)920N 500 1.75 3.08 3.78 —2.63 7.64 3.05 5.0 —32 3450 44.5 78 96 67 194 78 2.3 1 1/2 (a)920N 500 2.00 3.28 4.00 —2.63 7.64 3.25 5.0 —40 3450 50.8 83 102 67 194 83 2.3 2 (a)920N 500 2.50 3.25 4.00 —2.63 7.64 4.00 4.0 —50 3450 63.5 83 102 67 194 102 1.9 76.1 mm 920 500 2.75 2.88 4.00 4.00 2.63 7.64 4.29 8.0 —3450 69.9 73 102 102 67 194 109 3.6 3 (a)920 500 3.50 3.31 4.50 —2.63 7.63 4.88 6.8 6.5 80 3450 88.9 84 114 67 194 124 3.1 3.0 5 × 1 1/2 (a) †920 500 2.00 4.03 4.75 4.75 3.16 9.70 3.69 7.4 7.6 125 40 3450 50.8 102 121 121 80 246 94 3.4 3.4 2 (a) †920 500 2.50 4.00 4.75 4.75 3.16 9.70 4.38 8.2 8.0 50 3450 63.5 102 121 121 80 246 111 3.7 3.6 2 1/2 (a) †920 500 2.75 3.63 4.75 4.75 3.16 9.70 4.63 8.3 7.9 65 3450 69.9 92 121 121 80 246 118 3.8 3.6 76.1 mm 920 500 2.75 ——4.75 3.16 9.70 4.63 —8.0 3450 69.9 121 80 246 118 3.6 3 (a) †920 500 3.50 3.81 5.00 4.63 3.16 9.70 5.31 8.4 8.8 80 3450 88.9 97 127 118 80 246 135 3.8 4.0 133.0 × 2 920N 500 2.50 3.75 4.50 —3.17 8.00 3.88 8.0 —50 3450 63.5 95 114 81 203 99 3.6 3 920 500 3.50 3.81 5.00 —3.00 9.46 5.31 8.0 —80 3450 88.9 97 127 76 240 135 3.6 TABLE CONTINUED ON PG. 4 11.02_3 Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N 11.02IPS CARBON STEEL PIPE - HOLE CUT PRODUCTS www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2007 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. REV_J DIMENSIONS GROOVED OUTLET W ZY V FEMALE THREADED OUTLET T W ZY V Important notes: Style 920 and Style 920N housings cannot be mated to one another to achieve cross connections. • Provides a direct branch connection at any location where a hole can be cut in the pipe • A pressure responsive gasket provides the seal • Request Publication 11.03 for Mechanical-T cross assemblies • Pressure rated up to 500 psi/3450 kPa on steel pipe; also available for use with HDPE pipe • Sizes from 2 × ½"/50 × 15 mm through 8 × 4"/200 × 100 mm Size Style No. Max. Work Pressure Dimensions Approx. Weight Each Run × Branch Nominal Size Inches mm 920 or 920N psi kPa Hole Diameter +0.13 -0.00 T** Inches mm V ‡ # Thd. Inches mm V ‡ Grv. Inches mm W Inches mm Y Inches mm Z Inches mm Female Thd. Lbs. kg Grv. Lbs. kg TABLE CONTINUED FROM PAGE 3 139.7 × 1 1/2 †920N 500 2.00 3.78 4.50 —3.30 8.23 3.25 7.0 —40 3450 50.8 96 114 84 209 83 3.2 2 †920N 500 2.50 3.75 4.50 —3.30 8.23 3.88 9.0 —50 3450 63.5 95 114 84 209 99 4.1 76.1 mm 920 500 2.75 3.63 4.75 —3.13 9.85 4.63 8.8 —3450 69.9 92 121 80 250 118 4.0 76.1 mm 920 500 3.50 ——4.63 3.16 9.70 5.31 11.0 —3450 88.9 118 80 246 135 5.0 3 920 500 3.50 3.81 5.00 4.63 3.16 9.85 5.38 14.0 14.2 88.9 3450 88.9 96.80 127 118 80 250 137 6.4 6.4 6 × 1 1/4 (a)920N 500 1.75 4.43 ——3.79 9.15 3.25 —4.8 150 32 (b)3450 44.5 112 96 232 83 2.2 1 1/2 (a) †920N 500 2.00 4.40 5.13 5.13 3.79 9.15 3.25 5.4 5.1 40 (b)3450 50.8 112 130 130 96 232 83 2.4 2.3 2 (a) †920N 500 2.50 4.38 5.13 5.13 3.79 9.15 3.88 6.0 5.6 50 3450 63.5 111 130 130 96 232 99 2.7 2.5 2 1/2 (a) †920 500 2.75 4.01 5.13 5.12 3.69 10.51 4.63 8.3 7.6 65 3450 69.9 110 130 130 94 267 118 3.8 3.4 76.1 mm 920 500 2.75 ——5.21 3.69 10.51 4.63 —8.4 3450 69.9 132 94 267 118 3.8 3 (a) †920 500 3.50 4.31 5.50 5.13 3.69 10.51 5.31 9.9 8.4 80 3450 88.9 110 140 130 94 267 135 4.5 3.8 4 (a) †920 500 4.50 3.81 5.75 5.38 3.69 10.51 6.25 10.1 10.1 100 3450 114.3 97 146 137 94 267 159 4.6 4.6 159.0 × 1 1/4 920N 500 1.75 4.43 5.13 —3.63 9.40 3.25 9.0 8.7 32 3450 44.5 113 130 92 239 83 4.1 4.0 1 1/2 (a)920N 500 2.00 4.41 5.13 —3.63 9.40 3.25 7.8 —40 3450 50.8 112 130 92 239 83 3.5 2 (a)920N 500 2.50 4.38 5.13 —3.63 9.40 3.88 8.0 —50 3450 63.5 111 130 92 239 99 3.6 76.1 mm 920 500 2.75 4.38 5.50 5.13 3.63 9.40 4.63 9.5 9.5 3450 69.9 111 140 130 92 239 118 4.3 4.3 3 920 500 3.50 4.31 5.50 5.13 3.63 9.40 5.31 8.1 14.0 80 3450 88.9 110 140 130 92 239 135 3.7 6.4 108.1 mm 920 500 4.50 ——5.38 3.63 9.40 6.12 —10.0 3450 114.3 137 92 239 155 4.5 4 920 500 4.50 3.81 5.75 —3.63 9.40 6.25 18.0 —100 3450 114.3 96.80 146 92 239 159 8.2 TABLE CONTINUED ON PG. 5 11.02_4 Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N 11.02IPS CARBON STEEL PIPE - HOLE CUT PRODUCTS www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2007 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. REV_J Size Style No. Max. Work Pressure Dimensions Approx. Weight Each Run × Branch Nominal Size Inches mm 920 or 920N psi kPa Hole Diameter +0.13 -0.00 T** Inches mm V ‡ # Thd. Inches mm V ‡ Grv. Inches mm W Inches mm Y Inches mm Z Inches mm Female Thd. Lbs. kg Grv. Lbs. kg TABLE CONTINUED FROM PAGE 4 165.1 × 1 920 500 1.50 3.88 4.56 —3.79 9.34 2.75 8.0 —25 3450 38.1 99 116 96 237 70 3.6 1 1/4 920 500 1.75 4.43 5.13 —3.79 9.34 3.25 8.4 —32 3450 44.5 113 130 96 237 83 3.8 1 1/2 (a) †920 500 2.00 4.41 5.13 —3.79 9.34 3.25 8.4 —40 3450 50.8 112 130 96 237 83 3.8 2 (a) †920 500 2.50 4.38 5.13 —3.79 9.34 3.88 8.5 —50 3450 63.5 111 130 96 237 99 3.9 2 1/2 †920 500 2.75 4.01 5.13 —3.63 10.51 4.63 8.6 7.6 65 3450 69.9 110 130 92 267 118 3.9 3.4 76.1 mm 920 500 2.75 4.01 5.13 5.21 3.63 10.51 4.63 8.6 7.6 3450 69.9 110 130 132 92 267 118 3.9 3.4 3 (a) †920 500 3.50 4.31 5.50 5.13 3.63 10.51 5.31 10.2 8.4 80 3450 88.9 110 140 130 92 267 135 4.6 3.8 4 (a) †920 500 4.50 3.81 5.75 5.38 3.63 10.51 6.25 10.5 8.4 100 3450 114.3 97 146 137 92 267 159 4.8 3.8 8 × 2 (a) †920 500 2.75 5.44 6.19 6.25 4.81 12.42 4.50 11.6 11.6 200 50 3450 69.9 138 157 159 122 316 114 5.3 5.3 2 1/2 (a) †920 500 2.75 5.07 6.19 6.19 4.81 12.42 4.50 11.6 11.6 65 3450 69.9 129 157 157 122 316 114 5.3 5.3 76.1 mm 920 500 2.75 ——6.25 4.81 12.42 4.56 —11.6 3450 69.9 159 122 316 116 5.3 3 (a) †920 500 3.50 5.31 6.50 6.50 4.81 12.42 5.31 12.6 11.6 80 3450 88.9 135 165 165 122 316 135 5.7 5.3 4 (a) †920 500 4.50 4.81 6.75 6.38 4.81 12.42 6.25 15.3 12.5 100 3450 114.3 122 171 162 122 316 159 6.9 5.7 ** Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). † Available with grooved or female threaded outlet. Specify choice on order. ‡ Center of run to end of fitting. # Female threaded outlets are available to NPT and BSPT specifications. (a) British Standard female pipe threaded outlet is available as listed. Specify “BSPT” clearly on order. (b) For 76.1 mm threaded outlet, specify 21/2" BSPT clearly on order. dimensions GROOVED OUTLET W ZY V FEMALE THREADED OUTLET T W ZY V Important notes: Style 920 and Style 920N housings cannot be mated to each other to achieve cross connections. • Provides a direct branch connection at any location where a hole can be cut in the pipe • A pressure responsive gasket provides the seal • Request Publication 11.03 for Mechanical-T cross assemblies • Pressure rated up to 500 psi/3450 kPa on steel pipe; also available for use with HDPE pipe • Sizes from 2 × ½"/50 × 15 mm through 8 × 4"/200 × 100 mm 11.02_5 Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N 11.02IPS CARBON STEEL PIPE - HOLE CUT PRODUCTS www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2007 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. REV_J FLOW DATA Flow test data has shown that the total head loss between point (1) and (2) for the Style 920, 920N and 929 Mechanical-T® fittings can best be expressed in terms of the pressure difference across the inlet and branch. The pressure difference can be obtained from the relationship below. CV Values Values for flow of water at +60°F/+16°C are shown in the table below. SIZE Equivalent Length Feet/meter of Pipe SIZE Equivalent Length Feet/meter of Pipe Nominal Diameter In./mm Actual Out. Dia. In./mm Grooved Female Threaded Nominal Diameter In./mm Actual Out. Dia. In./mm Grooved Female Threaded 1/2 0.840 —2.0 2 2.375 9.0 10.5 15 21.3 0.6 50 60.3 2.7 3.2 3/4 1.050 —4.0 2 1/2 2.875 11.0 12.5 20 26.7 1.2 65 73.0 3.4 3.8 1 1.315 —5.0 3 3.500 13.5 15.5 25 33.7 1.5 80 88.9 4.1 4.7 1 1/4 1.660 5.5 6.0 4 4.500 20.0 22.0 32 42.4 1.7 1.8 100 114.3 6.1 6.7 1 1/2 1.900 7.0 8.0 40 48.3 2.1 2.4 Formulas for CV Values: ∆P = Q2 Cv 2 Where: Q = Flow (GPM) ∆P = Pressure Drop (psi) Cv = Flow CoefficientQ = Cv x ∆P Size CV Size CV Size CV Nominal Size Inches/mm Actual Outside Diameter Inches/mm Values Nominal Size Inches/mm Actual Outside Diameter Inches/mm Values Nominal Size Inches/mm Actual Outside Diameter Inches/mm Values 1/2 0.840 17 1 1/4 1.660 45 2 1/2 2.875 1351521.3 32 42.4 65 73.0 3/4 1.050 21 1 1/2 1.900 60 3 3.500 2002026.7 40 48.3 80 88.9 1 1.315 25 2 2.375 100 4 4.500 4002533.7 50 60.3 100 114.3 1 2 Exaggerated for clarity 11.02_ Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N 11.02IPS CARBON STEEL PIPE - HOLE CUT PRODUCTS www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2007 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. REV_J APPROVED PRESSURE RATINGS The information provided below is based on the latest listing and approval data at the time of publi- cation. Listings/Approvals are subject to change and/or additions by the approvals agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. Run Size Outlet Size Pipe Rated Working Pressures – psi/kPa Nominal Size Inches/mm Actual Outside Diameter Inches/mm Inches/mm Schedule UL ULC FM 21/2 - 6 2.875 - 6.625 All 10, 40 400 400 400 65 - 150 73.0 - 168.3 2755 2755 2755 21/2 - 4 2.875 - 4.500 All DF 300 300 300 65 - 100 73.0 - 114.3 2065 2065 2065 21/2 - 4 2.875 - 4.500 All SF 300 300 300 65 - 100 73.0 - 114.3 2065 2065 2065 6 6.625 3, 4 10 300 300 250 150 168.3 2065 2065 1724 6 6.625 3,4 30, 40 300 300 300 150 168.3 2065 2065 2065 8 8.625 21/2 10, 40 400 ——200 219.1 2755 8 8.625 3,4 10 300 —250 200 219.1 2065 1724 8 8.625 3,4 30, 40 300 —300 200 219.1 2065 2065 NOTES: 10 refers to Listed/Approved Schedule 10 steel sprinkler pipe. 40 refers to Listed/Approved Schedule 40 steel sprinkler pipe. DF refers to Listed/Approved Dyna-Flow steel sprinkler pipe manufactured by American Tube Company. SF refers to Listed/Approved Super-Flo steel sprinkler pipe manufactured by Allied Tube and Conduit Corporation. VIC-TAP II HOLE CUTTING TOOL FOR 4 - 8"/100 - 200 MM CARBON STEEL PIPE The Vic-Tap II hole cutting tool is designed for use with the Style 931 Vic-Tap II Mechanical-T unit, which is a combination of the Style 920 Mechanical-T and Series 726 Vic-Ball Valve. The Vic-Tap II is capable of tapping into carbon steel pipe systems under pressures up to 500 psi/3450 kPa. The Style 931 Vic-Tap II Mechanical-T unit is a full port ball valve which can be mounted on 4"/100 mm, 5"/125 mm, 6"/150 mm and 8"/200 mm diameter pipe. The Style 931 comes with a 2 ½"/65 mm grooved outlet. The drill motor is an electric motor with ground fault circuit interrupter (GFCI) in accordance with safety codes. For more information, refer to publication 24.01. 11.02_ Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N 11.02IPS CARBON STEEL PIPE - HOLE CUT PRODUCTS www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2007 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. REV_J WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. NOTE INSTALLATION Reference should always be made to the I-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. 11.02_8 Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N 11.02IPS CARBON STEEL PIPE - HOLE CUT PRODUCTS WCAS-6YCLDG For complete contact information, visit www.victaulic.com 11.02 1480 REV J UPDATED 4/200 VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2007 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. FireLock® Style 005 rigid coupling has a unique, patented angle-pad design which allows the housings to offset while clamping the grooves. By permitting the housings to slide on the angled bolt pads, rigidity is obtained. Support and hanging requirements correspond to NFPA 13 Sprinkler Systems. Angle-pad design permits assembly by removing one nut/bolt and swinging the housing over the gasket. This reduces components to handle during assembly. Style 005 FireLock coupling are designed and recommended for use ONLY on fire protection systems. Vic-Plus™ Gasket System: In North America, Victaulic® offers a gasket system which requires no field lubrication on wet pipe systems that are hydrostatically tested. The Vic-Plus™ System (patented) is dry, clean, and non-toxic. It reduces assembly time substantially and eliminates the mess and chance of over- lubrication. Please refer to the latest copy of the Victaulic Field Installation Handbook (I-100) for supplemental lubrication requirements and dry pipe fire protection system notes. LISTING/APPROVALS The information provided below is based on the latest listing and approval data at the time of publication. Listings/Approvals are subject to change and/or additions by the approvals agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. Related Working Pressure – psiRelated Working Pressure – psiRelated Working Pressure – psi Pipe Sch. Size InchesULULCFM Pipe Sch. Size InchesULULCFM Pipe Sch. Size InchesULULCFM 51 ¼ – 3175175175EL1 ¼ – 2300N/AN/AMT1 ¼ – 2300N/AN/A 10, 40 1 ¼ – 4350350350ET1 ¼ – 2300N/AN/ASTF1 ¼ – 4N/AN/A300 5 – 8300300300EZ4 – 6300#N/A300 Steady Thd.1 ¼ – 2N/AN/A300 BLT1 ¼ – 2300300N/AFF1 ¼ – 4N/AN/A300TF3 – 8N/AN/A300 DF1 ¼ – 4300300300GAL - 71 ¼ – 2300N/AN/AWLS1 ¼ – 2300300N/A DT1 ¼ – 2300300N/AMLT1 ¼ – 2300N/AN/AXL1 ¼ – 3300300300 EF1 1⁄ – 4175@N/A175MF1 ¼ – 4300N/A300* * FM approved for service in 1 ½ – 4" pipe. # UL Listed for service up to 4" pipe only. @ UL Listed for service up to 3" only. 10.02_1 FireLock® Rigid Coupling STYLE 005 WITH VIC-PLUS™ GASKET SYSTEM (NORTH AMERICA ONLY) 10.02IPS CARBON STEEL PIPE - FIRE PROTECTION PRODUCTS JOB/OWNERCONTRACTORENGINEER System No. __________________________Submitted By ________________________Spec Sect ____________ Para __________ Location ____________________________Date ________________________________Approved ___________________________ Date ________________________________ www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2006 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. REV_I SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS § LPC and VdS Approved, see notes on page 4 PATENTED Exaggerated for clarity DIMENSIONS Size Max. Work Pressure § * Max. End Load * Allow. Pipe End Sep. † Bolt/Nut@ No – SizeDimensions – Inches/mm Approx. Wgt. Each Nominal Size Inches/mm Actual Outside Diameter Inches/mm PSI kPa Lbs. N Inches mm Inches mmXYZ Lbs. kg 1 ¼ 1.6603507550.05 2 – 3⁄8 x 2 ¼ 2.754.501.881.2 3242.4241333701.2701141480.5 1 ½ 1.9003509900.05 2 – 3⁄8 x 2 ¼ 3.004.751.881.2 4048.3241344151.2761211480.5 22.37535015500.072 – 3⁄8 x 2 ½ 3.505.251.881.6 5060.3241369001.7891331480.7 2 ½ 2.87535022700.07 2 – 3⁄8 x 2 ½ 4.005.751.881.9 6573.02413101101.7102146148.09 76.1 mm 3.00035024750.07 2 – 3⁄8 x 2 ½ 4.135.751.881.9 76.12413110101.71051461480.9 33.50035033650.072 – 3⁄8 x 2 ½ 4.636.131.882.1 8088.92413149851.71181561481.0 44.50035055650.162 – 3⁄8 x 2 ½ 5.757.252.133.1 100114.32413247704.1146184541.4 108.0 mm 4.25030042550.16 2 – 3⁄8 x 2 ½ 5.637.252.133.1 108.02068189404.1143184541.4 55.56330072900.162 – ½ x 3 6.889.002.134.5 125141.32068324454.1175229542.0 133.0 mm 5.25030064950.16 2 – ½ x 2 ¾ 6.639.002.134.5 133.02068289004.1168229542.0 139.7 mm 5.50030071250.16 2 – ½ x 2 ¾ 6.889.002.134.8 139.72068317154.1175229542.2 66.625300103400.162 – ½ x 3 8.0010.002.135.0 150168.32068460204.1203254532.3 159.0 mm 6.25030092000.16 2 – ½ x 2 ¾ 7.6310.002.135.5 159.02068409554.1194254542.5 165.1 mm 6.50030099550.16 2 – ½ x 3 8.1510.002.135.5 165.12068442954.1207254542.5 88.625300175250.19 2 – 5⁄8 x 4 ¼ 10.5013.142.6311.3 200219.12068780004.8267334675.1 * Working Pressure and End Load are total, from all internal and external loads, based on standard weight (ANSI) steel pipe, standard roll or cut grooved in accordance with Victaulic specifications. Contact Victaulic for perfor- mance on other pipe. WARNING: FOR ONE TIME FIELD TEST ONLY, the Maximum Joint Working Pressure may be increased to 1 1/2 times the figures shown. † The allowable pipe separation dimension shown is for system layout purposes only. Style 005 couplings are con- sidered rigid connections and will not accommodate expansion or contraction of the piping system. @ Number of bolts required equals number of housing segments. Metric thread size bolts are available (color coded gold) for all coupling sizes upon request. Contact Victaulic for details. § Style 005 couplings are VdS and LPC Approved to 12 Bar/175 psi. Rated for wet and dry sprinkler systems at 350 psi/2413 kPa for 1 ¼ – 4"/32 – 100 mm sizes and 300 psi /2068 kPa for 4 ¼ – 8"/108 – 200 mm sizes; Schedule 10 roll grooved or Schedule 40 cut or roll grooved steel pipe. Style 005 is rigid and does not accommodate expansion, contraction or angular deflection. X ZY 10.02_2 FireLock ® Rigid Coupling STYLE 005 WITH VIC-PLUS™ GASKET SYSTEM (NORTH AMERICA ONLY) 10.02IPS CARBON STEEL PIPE - FIRE PROTECTION PRODUCTS www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2006 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. REV_I MATERIAL SPECIFICATIONSHousing: Ductile iron conforming to ASTM A-536, grade 65-45-12. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Housing Coating: Orange enamel (North America); red enamel (Europe) • Optional: Hot dipped galvanized Gasket: • Grade “E” EPDM – Type A Vic-Plus™ Gasket System Δ (Violet color code). FireLock products have been Listed by Underwriters Laboratories Inc. and Approved by Factory Mutual Research for wet and dry (oil free air) sprinkler services up to the rated working pressure using the Grade “E” Type A Vic-Plus™ Gasket System, requiring no field lubrication for most installation conditions. • Grade “L” Silicone Recommended for dry heat, air without hydrocarbons to +350°F and certain chemical services. For dry services, Victaulic continues to recommend the use of Grade “E” Type A FlushSeal® Gasket. Contact Victaulic for details. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. Δ Standard gasket and FlushSeal gasket approved for dry pipe systems to –40°F/–40°C. Based on “typical” pipe surface conditions, supplemental lubricant is recommended for services installed below 0°F/–18°C and for all dry pipe systems or systems to be subjected to air tests prior to being filled with water. Supplemental lubrication may also be required on pipe with raised or undercut weld seams or pipe that has voids and/or cracks at the weld seams. Victaulic continues to recommend the use of FlushSeal gaskets for dry services. 10.60_3 FireLock® Rigid Coupling STYLE 005 WITH VIC-PLUS™ GASKET SYSTEM (NORTH AMERICA ONLY) 10.02IPS CARBON STEEL PIPE - FIRE PROTECTION PRODUCTS www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2006 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. REV_I WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. NOTE WARNING: Depressurize and drain the piping system before attempting to install, remove, or adjust any Victaulic piping products. GENERAL NOTES INSTALLATION Reference should always be made to the I-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. 10.02 FireLock ® Rigid Coupling STYLE 005 WITH VIC-PLUS™ GASKET SYSTEM (NORTH AMERICA ONLY) 10.02IPS CARBON STEEL PIPE - FIRE PROTECTION PRODUCTS For complete contact information, visit www.victaulic.com 10.02 1538 REV I UPDATED 9/2006 VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2006 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. WCAS-697KR4 Project InformatIon :aPProval Stam P: Project: Date:Phone: Architect / Engineer: Contractor: Address: Notes 1: Notes 2: Rev. 03.03.06-003 For the latest UL/ULC Listed and FM Approved pressure ratings, versus pipe schedule, go to www.anvilstar.com or contact your local AnvilStar representative Submittal Sheet SPF Cast & Ductile Iron Fittings ® Material Specification S Ductile iron threaded fittings are UL & ULC Listed & Factory Mutual Approved for 500 psi service. Ductile iron per ASTM A536 Class 65-45-2. Dimensions conform to ASMe B6.3 Class 50. Threads are NPT per ANSI/ASMe B.20.. Notice: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened three turns beyond hand tight, but no more than four turns. Straight tee Nominal Size Anvil Item Number Universal Number Max. Working Pressure Dimensions Approx. Wt. Each A B In. (mm)PSI (kPa)In. (mm)In. (mm)Lbs. (kg) 1 840003164 DT333 500 1.50 1.50 0.85 25 3450 38.10 38.10 0.39 11⁄4 840003172 DT444 500 1.75 1.75 1.22 32 3450 44.45 44.45 0.55 11⁄2 840003180 DT555 500 1.94 1.94 1.55 40 3450 49.27 49.27 0.70 2 840003198 DT666 500 2.25 2.25 2.45 50 3450 57.15 57.15 1.11 B AA Straight tee Ductile Iron Project InformatIon :aPProval Stam P: Project: Date:Phone: Architect / Engineer: Contractor: Address: Notes 1: Notes 2: Rev. 03.03.06-004 For the latest UL/ULC Listed and FM Approved pressure ratings, versus pipe schedule, go to www.anvilstar.com or contact your local AnvilStar representative Submittal Sheet SPF Cast & Ductile Iron Fittings ® Material Specification S Ductile iron threaded fittings are UL & ULC Listed & Factory Mutual Approved for 500 psi service. Ductile iron per ASTM A536 Class 65-45-2. Dimensions conform to ASMe B6.3 Class 50. Threads are NPT per ANSI/ASMe B.20.. Notice: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened three turns beyond hand tight, but no more than four turns. reducing tee Nominal Size Anvil Item Number Universal Number Max. Working Pressure Dimensions Approx. Wt. EachABC In. (mm)PSI (kPa)In. (mm)In. (mm)In. (mm)Lbs.(kg) 11⁄2 x 11⁄4 x 1 840004428 DT543 500 1.65 1.58 1.80 1.2540 x 32 x 25 3450 41.91 40.13 45.72 0.5711⁄2 x 11⁄4 x 2 840004436 DT546 500 2.16 2.10 2.02 1.9040 x 32 x 50 3450 54.86 53.34 51.30 0.8611⁄2 x 11⁄2 x 1⁄2 840004444 DT551 500 1.41 1.41 1.16 1.1540 x 40 x 15 3450 35.81 35.81 29.46 0.5211⁄2 x 11⁄2 x 3⁄4 840004451 DT552 500 1.52 1.52 1.75 1.2440 x 40 x 20 3450 38.61 38.61 44.45 0.5611⁄2 x 11⁄2 x 1 840004469 DT553 500 1.65 1.65 1.80 1.3040 x 40 x 25 3450 41.91 41.91 45.72 0.5911⁄2 x 11⁄2 x 11⁄4 840004477 DT554 500 1.82 1.82 1.88 1.4840 x 40 x 32 3450 46.23 46.23 47.75 0.6711⁄2 x 11⁄2 x 2 840004485 DT556 500 2.16 2.16 2.02 1.9840 x 40 x 50 3450 54.86 54.86 51.30 0.902 x 1 x 2 840004493 DT636 500 2.25 2.02 2.25 2.1550 x 25 x 50 3450 57.15 51.31 57.15 0.982 x 11⁄4 x 2 840004501 DT646 500 2.25 2.10 2.25 2.3050 x 32 x 50 3450 57.15 53.34 57.15 1.042 x 11⁄2 x 1⁄2 840004519 DT651 500 1.49 1.41 1.88 1.5050 x 40 x 15 3450 37.85 35.81 47.75 0.682 x 11⁄2 x 3⁄4 840004527 DT652 500 1.60 1.52 1.97 1.6250 x 40 x 20 3450 40.64 38.61 50.04 0.732 x 11⁄2 x 1 840004535 DT653 500 1.73 1.65 2.02 1.6450 x 40 x 25 3450 43.94 41.91 51.31 0.742 x 11⁄2 x 11⁄4 840004543 DT654 500 1.90 1.82 2.10 1.8050 x 40 x 32 3450 48.26 46.23 53.34 0.822 x 11⁄2 x 11⁄2 840004550 DT655 500 2.02 1.94 2.16 2.0050 x 40 x 40 3450 51.31 49.28 54.86 0.912 x 11⁄2 x 2 840004568 DT656 500 2.25 2.16 2.25 2.3550 x 40 x 50 3450 57.15 54.86 57.15 1.072 x 2 x 1⁄2 840004576 DT661 500 1.49 1.49 1.88 1.6050 x 50 x 15 3450 37.85 37.85 47.75 0.732 x 2 x 3⁄4 840004584 DT662 500 1.60 1.60 1.97 1.6850 x 50 x 20 3450 40.64 40.64 50.04 0.762 x 2 x 1 840004592 DT663 500 1.73 1.73 2.02 1.8550 x 50 x 25 3450 43.94 43.94 51.31 0.842 x 2 x 11⁄4 840004600 DT664 500 1.90 1.90 2.10 2.0450 x 50 x 32 3450 44.45 42.42 44.45 0.932 x 2 x 11⁄2 840004618 DT665 500 2.02 2.02 2.16 2.1850 x 50 x 40 3450 44.45 42.42 44.45 0.992 x 2 x 21⁄2 -DT667 500 2.60 2.60 2.39 3.6150 x 50 x 65 3450 44.45 42.42 44.45 1.6421⁄2 x 2 x 3⁄4 -DT762 500 1.74 1.60 2.32 2.2865 x 50 x 20 3450 44.45 42.42 44.45 1.03 reducing tee Nominal Size Anvil Item Number Universal Number Max. Working Pressure Dimensions Approx. Wt. EachABC In. (mm)PSI (kPa)In. (mm)In. (mm)In. (mm)Lbs.(kg) 1 x 1⁄2 x 1 840004196 DT313 500 1.50 1.36 1.50 0.6425 x 15 x 25 3450 38.10 34.54 38.10 0.291 x 3⁄4 x 1 840004204 DT323 500 1.50 1.45 1.50 0.7325 x 20 x 25 3450 38.10 36.83 38.10 0.331 x 1 x 1⁄2 840004212 DT331 500 1.26 1.26 1.36 0.7125 x 25 x 15 3450 32.00 32.00 34.54 0.321 x 1 x 3⁄4 840004220 DT332 500 1.37 1.37 1.45 0.7625 x 25 x 20 3450 34.80 34.80 36.83 0.341 x 1 x 11⁄4 840004238 DT334 500 1.67 1.67 1.58 0.9825 x 25 x 32 3450 42.41 42.41 40.13 0.441 x 1 x 11⁄2 840004246 DT335 500 1.80 1.80 1.65 1.1625 x 25 x 40 3450 45.72 45.72 41.91 0.5311⁄4 x 1 x 1⁄2 840004253 DT431 500 1.34 1.26 1.53 0.8232 x 25 x 15 3450 34.04 32.00 38.86 0.3711⁄4 x 1 x 3⁄4 840004261 DT432 500 1.45 1.37 1.62 0.9032 x 25 x 20 3450 36.83 34.80 41.15 0.4111⁄4 x 1 x 1 840004279 DT433 500 1.58 1.50 1.67 1.0032 x 25 x 25 3450 40.13 38.10 42.42 0.4511⁄4 x 1 x 11⁄4 840004287 DT434 500 1.75 1.67 1.75 1.0832 x 25 x 32 3450 44.45 42.42 44.45 0.4911⁄4 x 1 x 11⁄2 840004295 DT435 500 1.88 1.80 1.82 1.4232 x 25 x 40 3450 47.75 45.72 46.22 0.6411⁄4 x 11⁄4 x 1⁄2 840004303 DT441 500 1.34 1.34 1.53 0.8632 x 32 x 15 3450 34.04 34.04 38.86 0.3911⁄4 x 11⁄4 x 3⁄4 840004311 DT442 500 1.45 1.45 1.62 0.9232 x 32 x 20 3450 36.83 36.83 41.15 0.4211⁄4 x 11⁄4 x 1 840004329 DT443 500 1.58 1.58 1.67 0.9532 x 32 x 25 3450 40.13 40.13 42.42 0.4311⁄4 x 11⁄4 x 11⁄2 840004337 DT445 500 1.88 1.88 1.82 1.4532 x 32 x 40 3450 47.75 47.75 46.22 0.6611⁄4 x 11⁄4 x 2 840004345 DT446 500 2.10 2.10 1.90 1.7532 x 32 x 50 3450 53.34 53.34 48.26 0.7911⁄2 x 1 x 1⁄2 840004352 DT531 500 1.41 1.34 1.66 0.9540 x 25 x 15 3450 35.81 34.04 42.16 0.4311⁄2 x 1 x 3⁄4 840004360 DT532 500 1.52 1.37 1.75 1.1440 x 25 x 20 3450 38.61 34.80 44.45 0.5211⁄2 x 1 x 1 840004378 DT533 500 1.65 1.50 1.80 1.1740 x 25 x 25 3450 41.91 38.10 45.72 0.5311⁄2 x 1 x 11⁄4 840004386 DT534 500 1.82 1.67 1.88 1.3440 x 25 x 32 3450 46.23 42.42 47.75 0.6111⁄2 x 1 x 11⁄2 840004394 DT535 500 1.94 1.80 1.94 1.4540 x 25 x 40 3450 49.28 45.72 49.28 0.6611⁄2 x11⁄4 x 1⁄2 840004402 DT541 500 1.41 1.34 1.66 1.0540 x 32 x 15 3450 35.81 34.04 42.16 0.4811⁄2 x11⁄4 x 3⁄4 840004410 DT542 500 1.52 1.45 1.75 1.1540 x 32 x 20 3450 38.61 36.83 44.45 0.52 C BA reducing tee Ductile Iron Project InformatIon :aPProval Stam P: Project: Date:Phone: Architect / Engineer: Contractor: Address: Notes 1: Notes 2: Rev. 03.03.06-002 For the latest UL/ULC Listed and FM Approved pressure ratings, versus pipe schedule, go to www.anvilstar.com or contact your local AnvilStar representative Submittal Sheet SPF Cast & Ductile Iron Fittings ® Material Specification S Ductile iron threaded fittings are UL & ULC Listed & Factory Mutual Approved for 500 psi service. Ductile iron per ASTM A536 Class 65-45-2. Dimensions conform to ASMe B6.3 Class 50. Threads are NPT per ANSI/ASMe B.20.. Notice: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened three turns beyond hand tight, but no more than four turns. reducing 90° elbow Nominal Size Anvil Item Number Universal Number Max. Working Pressure Dimensions Approx. Wt. Each A B In. (mm)PSI (kPa)In. (mm)In. (mm)Lbs. (kg) 1 x 1⁄2 840001036 DB90031 500 1.26 1.36 0.44 25 x 15 3450 32.00 34.54 0.20 1 x 3⁄4 840001044 DB90032 500 1.37 1.45 0.52 25 x 20 3450 34.79 36.83 0.24 11⁄4 x 1⁄2 840001051 DB90041 500 1.34 1.53 0.64 32 x 15 34550 34.03 38.86 0.29 11⁄4 x 3⁄4 840001069 DB90042 500 1.45 1.62 0.72 32 x 20 3450 36.83 41.14 0.33 11⁄4 x 1 840001077 DB90043 500 1.58 1.67 0.75 32 x 25 3450 40.13 42.41 0.34 11⁄2 x 1 840001085 DB90053 500 1.65 1.80 0.92 40 x 25 3450 41.91 45.72 0.42 11⁄2 x 11⁄4 840001093 DB90054 500 1.82 1.88 1.08 40 x 32 3450 46.22 47.75 0.49 2 x 1⁄2 840001101 DB90061 500 1.49 1.88 1.08 50 x 15 3450 37.84 47.75 0.49 2 x 3⁄4 840001119 DB90062 500 1.60 1.97 1.24 50 x 20 3450 40.64 50.03 0.56 2 x 1 840001127 DB90063 500 1.73 2.02 1.40 50 x 25 3450 43.94 51.30 0.64 2 x 11⁄4 840001135 DB90064 500 1.90 2.10 1.52 50 x 32 3450 48.26 53.34 0.70 2 x 11⁄2 840001143 DB90065 500 2.02 2.16 1.65 50 x 40 3450 51.30 54.86 0.75 A B reducing 90° elbow Ductile Iron Project InformatIon :aPProval Stam P: Project: Date:Phone: Architect / Engineer: Contractor: Address: Notes 1: Notes 2: Rev. 03.03.06-00 For the latest UL/ULC Listed and FM Approved pressure ratings, versus pipe schedule, go to www.anvilstar.com or contact your local AnvilStar representative Submittal Sheet SPF Cast & Ductile Iron Fittings ® Material Specification S Ductile iron threaded fittings are UL & ULC Listed & Factory Mutual Approved for 500 psi service. Ductile iron per ASTM A536 Class 65-45-2. Dimensions conform to ASMe B6.3 Class 50. Threads are NPT per ANSI/ASMe B.20.. Notice: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened three turns beyond hand tight, but no more than four turns. reducing coupling Nominal Size Anvil Item Number Universal Number Max. Working Pressure DimensionsA Approx. Wt. Each In. (mm)PSI (kPa)In. (mm)Lbs. (kg) 1 x 1⁄2 840010755 DRC031 500 1.69 0.39 25 x 15 3450 42.92 0.18 1 x 3⁄4 840010763 DRC032 500 1.69 0.53 25 x 20 3450 42.92 0.24 A reducing couplling Ductile Iron Project InformatIon :aPProval Stam P: Project: Date:Phone: Architect / Engineer: Contractor: Address: Notes 1: Notes 2: Rev. 03.03.06-005 For the latest UL/ULC Listed and FM Approved pressure ratings, versus pipe schedule, go to www.anvilstar.com or contact your local AnvilStar representative Submittal Sheet SPF Cast & Ductile Iron Fittings ® Material Specification S Ductile iron threaded fittings are UL & ULC Listed & Factory Mutual Approved for 500 psi service. Ductile iron per ASTM A536 Class 65-45-2. Dimensions conform to ASMe B6.3 Class 50. Threads are NPT per ANSI/ASMe B.20.. Notice: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened three turns beyond hand tight, but no more than four turns. bull head tee Nominal Size Anvil Item Number Universal Number Max. Working Pressure Dimensions Approx. Wt. Each A B C In. (mm)PSI (kPa)In. (mm)In. (mm)In. (mm)Lbs. (kg) 1 x 1 x 11⁄4 840004238 DT334 500 1.67 1.67 1.58 0.98 25 x 25 x 32 3450 42.41 42.41 40.13 0.44 1 x 1 x 11⁄2 840004246 DT335 500 1.80 1.80 1.65 1.16 25 x 25 x 40 3450 45.72 45.72 41.91 0.53 11⁄4 x 1 x 11⁄2 840004295 DT435 500 1.88 1.80 1.82 1.42 32 x 25 x 40 3450 47.75 45.72 46.22 0.64 11⁄4 x 11⁄4 x 11⁄2 840004337 DT445 500 1.88 1.88 1.82 1.45 32 x 32 x 40 3450 47.75 47.75 46.22 0.66 11⁄4 x 11⁄4 x 2 840004345 DT446 500 2.10 2.10 1.90 1.75 32 x 32 x 50 3450 53.34 53.34 48.26 0.79 11⁄2 x 11⁄4 x 2 840004436 DT546 500 2.16 2.10 2.02 1.90 40 x 32 x 50 3450 54.86 53.34 51.30 0.86 11⁄2 x 11⁄2 x 2 840004485 DT556 500 2.16 2.16 2.02 1.98 40 x 40 x 50 3450 54.86 54.86 51.30 0.90 C BA bull head tee Ductile Iron Project InformatIon :aPProval Stam P: Project: Date:Phone: Architect / Engineer: Contractor: Address: Notes 1: Notes 2: Rev. 03.03.06-000 For the latest UL/ULC Listed and FM Approved pressure ratings, versus pipe schedule, go to www.anvilstar.com or contact your local AnvilStar representative Submittal Sheet SPF Cast & Ductile Iron Fittings ® Material Specification S Ductile iron threaded fittings are UL & ULC Listed & Factory Mutual Approved for 500 psi service. Ductile iron per ASTM A536 Class 65-45-2. Dimensions conform to ASMe B6.3 Class 50. Threads are NPT per ANSI/ASMe B.20.. Notice: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened three turns beyond hand tight, but no more than four turns. 90° elbow Nominal Size Anvil ItemNumber Universal Number Max. Working Pressure Dimensions- In.(mm)Approx. Wt. Each A B In. (mm)PSI (kPa)In. (mm)In. (mm)Lbs. (kg) 1 840000004 DB90033 500 1.50 1.50 0.62 20 3450 38.10 38.10 0.28 11⁄4 840000012 DB90044 500 1.75 1.75 0.90 32 3450 44.45 44.45 0.41 11⁄2 840000020 DB90055 500 1.94 1.94 1.20 40 3450 49.276 49.276 0.54 2 840000038 DB90066 500 2.25 2.25 1.85 50 3450 57.15 57.15 0.84 B A 90° elbow Ductile Iron 4 For the most up to date information, visit www.sammysuperscrew.com Wood Flooring Wood Joist Double Sheetrock Ceiling Approvals Rod Size Part Number Model Screw Descriptions Ultimate Pullout (lbs) UL Test Load (lbs) FM Test Load (lbs) Box Qty Case Qty 1/4"8002957 GST 100 1/4 x 1"210 (7/16” OSB) 670 (3/4” Ply)25 125 1/4"8003957 GST 200 1/4 x 2"1760 (Fir)25 125 1/4"8004957 GST 300 1/4 x 3"2060 (Fir)25 125 3/8"8006957 GST .75 1/4 x 3/4"564 (3/4" Ply)25 125 3/8"8007957 GST 10 1/4 x 1"210 (7/16” OSB) 670 (3/4” Ply)300 25 125 3/8"8008957 GST 20 1/4 x 2"1760 (Fir)850 1475 25 125 3/8"8068925 GST 20-SS 1/4 x 2"1760 (Fir)850 25 125 3/8"8009925 GST 25-380 3/8 x 2-1/2"2113 (Fir)1500 25 125 3/8"8010957 GST 30 1/4 x 3"2060 (Fir)1500 1475 25 125 3/8"8069925 GST 30-SS 1/4 x 3"2060 (Fir)25 125 3/8"8011925 GST 40 1/4 x 4"2180 (Fir)25 125 3/8"8012925 GST 60 1/4 x 6"2230 (Fir)25 125 1/2"8013925 GST 2 1/4 x 2"1760 (Fir)25 125 1/2"8014925 GST 2.5-380 3/8 x 2-1/2"2113 (Fir)25 125 1/2"8015925 GST 3 1/4 x 3"2275 (Fir)25 125 1/2"8016925 GST 4 1/4 x 4"2180 (Fir)25 125 1/2"8017925 GST 6 1/4 x 6"2230 (Fir)25 125 Not less than 2” nominal width (1-1/2”) Not less than 3” nominal thickness (2-1/2”) (depth or side of vertical member) VERTICAL MOUNT WO O D W O O D W O O D W O O D W O O D SAMMYS® for Wood Installs VERTICALLY into the bottom of wood structures easily and quickly! #14 Black Nut Driver Part # 8113910 SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. #14 SW Red Nut Driver Part # 8114910 Composite / Truss Consult truss manufacturer for recommended installation point. *Pre-drilling may be required for GST 25-380 . Tool available on page 10. For vertical use - install in center of lower face. Minimum 2” embedment into base material for NFPA 13 compliance. Approvals Rod Size Part Number Model Screw Descriptions Ultimate Pullout (lbs) UL Test Load (lbs) FM Test Load (lbs) Min Thickness Box Qty Case Qty 3/8"8139957 SH-GST 20 1/4 x 2"1257 (Fir)1050 1475 25 125 125 3/8"8141957 SH-GST 30 1/4 x 3"1720 (Fir)1500 1475 25 125 #14 Black Nut Driver Part # 8113910 SAMMY Swivel Head® for Wood Product Features • No pre-drilling required. • Quick to install using the Sammy Nut Driver with an 18V cordless drill/driver. • Saves time from traditional methods. • Reduces installation cost. • Made in the U.S.A. Product Features • Eliminates distortion of threaded rod. • Accommodates up to 3 ½” x 12 pitch roof. • Allows 17° deflection from vertical. • Saves time from traditional methods. • Reduces installation cost. • Made in the U.S.A. Installs VERTICALLY and swivels up to 17° in wood structure 5 To find a distributor near you, call 800-BUILDEX Not less than 2” nominal width (1-1/2”) up to 3-1/2” pipe; not less than 3” (2-1/2”) nominal width 4” & 5” pipe Minimum 2-1/2” from bottom for branch lines. Minimum 3” from bottom for main lines. Exception: This requirement shall not apply to 2” or thicker nailing strips resting on top of steel beams. Floor Joist HORIZONTAL MOUNT WO O D W O O D W O O D W O O D W O O D SIDEWINDERS® for Wood Installs HORIZONTALLY into the side of wood structures easily and quickly! Approvals Rod Size Part Number Model Screw Descriptions Ultimate Pullout (lbs) UL Test Load (lbs) Box Qty Case Qty 1/4"8018957 SWG 100 1/4 x 1"622 (Fir)25 125 1/4"8019957 SWG 200 1/4 x 2"1725 (Fir)25 125 3/8"8020957 SWG 10 1/4 x 1"622 (Fir)300 25 125 3/8"8021957 SWG 20 1/4 x 2"1725 (Fir)1050 25 125 3/8"8073925 SWG 20-SS 1/4 x 2"1725 (Fir)850 25 125 3/8"8022925 SWG 25-380 3/8 x 2-1/2"2249 (Fir)1500 25 125 3/8"8023925 SWG 30 1/4 x 3"1884 (Fir)25 125 #14 SW Red Nut Driver Part # 8114910 SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. INSTALLATION STEPS - VERTICAL INTO WOOD & STEEL: 1. Insert the appropriate nut driver into a 3/8” or 1/2” portable drill. 2. Insert the SAMMYS into the #14 (black) nut driver (p/n 8113910). Drill should be in a vertical position. 3. Push the face of the nut driver tight to the member. When the nut driver spins freely on the SAMMYS, stop drill and remove. 4. The SAMMYS is now ready to receive 1/4”, 3/8”, 1/2” or metric all thread rod, bolt stock. (The 1/2” requires the #14SW red nut driver) Note: When installing DSTR, follow the above instructions, then add retainer nut and torque to 20 foot lbs. for maximum pullout in purlin steel. INSTALLATION STEPS - HORIZONTAL INTO WOOD & STEEL: 1. Insert the appropriate nut driver into a 3/8” or 1/2” portable drill. 2. Insert the SAMMYS into the #14SW (red) nut driver (p/n 8114910). With drill unit in a horizontal position and at a right angle to the structural member, begin installation. 3. When the nut driver spins free on the SAMMYS, stop the drill and remove. 4. The unit is now ready to receive 1/4”, 3/8” or metric all thread rod or bolt stock. Note: When installing SWDR, follow the above instructions, then add retainer nut and torque to 20 foot lbs. for maximum pullout in purlin steel. Composite/Truss Consult truss manufacturer for recommended installation point. *Pre-drilling may be required for Model SWG 25-380 (tools available on pg 10 ) Product Features • No pre-drilling required. • Quick to install using the Sammy Nut Driver with an 18V cordless drill/driver. • Saves time from traditional methods. • Reduces installation cost. • Made in the U.S.A. Installs VERTICALLY and swivels up to 17° in wood structure Main Office/Manufacturing Facility•1375 Sampson Ave. •Corona, CA 92879 •Ph: 909.737.5599 •Fax: 909.737.0330 Customer Service•800.786.5266 www.tolco.com 86 wwwwww..ttoollccoo..ccoomm Revision 5/24/2001 ™ ® a brand of Fig.200 - “Trimline”Adjustable Band Hanger Size Range — 1/2" thru 8" pipe Material — Carbon Steel, Mil.Galvanized to G90 specifications Function — For fire sprinkler and other general piping purposes.Knurled swivel nut design permits hanger adjustment after installation. Features — •(1/2" thru 2") Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion.Captured design keeps adjusting nut from separating with hanger.Hanger is easily installed around pipe. •(21/2" thru 8" Spring tension on nut holds it securely in hanger before installation.Adjusting nut is easily removed. Approvals — Underwriters’Laboratories listed (1/2" thru 8") in the USA (UL)and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (3/4" thru 8").Conforms to Federal Specifications WW-H-171E, Type 10 and Manufacturers Standardization Society SP-69, Type 10. Maximum Temperature — 650°F Finish — Mil.Galvanized.For Stainless Steel materi- als, order TOLCO™ Fig.200WON. Order By — Figure number and pipe size Dimensions • Weights Pipe Rod SizeMax.Rec.Approx. SizeInchMetric ABLoad Lbs.Length 1/23/88mm or 10mm31/8 25/8 40011 3/43/88mm or 10mm31/8 21/2 40011 13/88mm or 10mm33/8 25/8 40012 11/4 3/88mm or 10mm33/4 27/8 40013 11/2 3/88mm or 10mm37/8 27/8 40014 23/88mm or 10mm41/2 340015 21/2 3/810mm55/8 41/8 60027 33/810mm57/8 460029 31/2 3/810mm73/8 51/4 60034 43/810mm73/8 5100035 51/212mm91/8 61/4 125066 61/212mm101/8 63/4 125073 81/212mm131/8 83/4 1250136 Office/Manufacturing Facility•1375 Sampson Ave. •Corona, CA 92879 •Ph: 951.737.5599 •Fax: 951.737.0330 Customer Service•800.786.5266 www.tolco.com 72 www.tolco.com Revision 5/24/2001 ™ ® a brand of Fig.98 - Rod Stiffener Size Range — Secures 3/8" thru 7/8" hanger rod Material — Carbon Steel Function — Secures channel to hanger rod for vertical seismic bracing. Finish — Electro Galvanized Note — Available in HDG finish or Stainless Steel materials. Order By — Figure number Fig.99 - All ThreadRodCut to Length Size Range — Secures 3/8" thru 7/8" rod in 1" increments Material — Carbon Steel Maximum Temperature — 750°F Finish — Plain Note — Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By — Figure number, rod diameter, rod length and finish Fig.100 - All ThreadRodFullLengths Size Range — Secures 3/8" thru 7/8" rod in 10’lengths Material — Carbon Steel Maximum Temperature — 750°F Finish — Plain Note — Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By — Figure number, rod diameter and finish Dimensions • Weights RodMax.Rec.Load Lbs. SizeFor Service Temps 650°F750°F 3/8610540 1/211301010 5/818101610 3/427102420 7/837703360 Dimensions • Weights Max Rec.Load Lbs. RodFor Service TempsApprox. Size650°F750°FWt./100 1/424021512 3/861054029 1/21130101053 5/81810161084 3/427102420123 7/837703360169 149604420222 11/4 80007140360 11/2 1163010370510 Tyco Fire Products Model CV-1F Check Valve Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 www.tyco-fire.com September 2004 TFP1550Page 1 of 2 The Model CV-1F Fire Protection Check Valve is furnished with grooved ends and can be installed using grooved couplings. The Model CV-1F can be installed with ANSI class 150 Flanges utilizing Grinnell Figure 71 flange adapters and also ANSI class 300 Flange Adapters. All Model CV-1F Check Valves have been designed with a removable cover for ease of field maintenance. Valves installed horizontally or inclined (flow up or down) are to be positioned with the cap facing up. Valves installed vertically may be positioned with flow up or down. A Maintenance Check Valve Kit is available to allow the maintenance procedure of backflushing through the fire department connection without removing the Model CV-1F Check Valve from the pipe line. The Model CV-1F Check Valves are a redesignation for the Central Figure 590F and Grinnell Figure 590F. WARNING The Model CV-1F Check Valve described herein must be installed and maintained in compliance with this document, as well as with the applicable standards of the National Fire Protection Association, in addition to the standards of any other authorities having jurisdiction. Failure to do so may impair the performance of this device. The owner is responsible for maintaining their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Model: CV-1F Sizes: 2", 21⁄2", 76.1mm, 3", 4", 139.7mm, 5", 165.1mm, 6", 8", 10" and 12" Max. Working Pressure: 300 psi (2068 kPa) Factory Hydro Test: 100% at 600 psi (4137 kPa) - Seat and shell complies with test requirements of MSS SP-71, UL, FM and ULC Approvals: UL, FM and ULC; See Fire Protection Submittal Sheet for exact Listing / Approval information. Body and Cap: Ductile iron conforming to ASTM A-536, Grade 65-45-12 Clapper: Stainless Steel (2" - 8") or Ductile Iron (10" and 12") Seal: Grade “E” EPDM Protective Coatings: Valve assembly • Non-lead paint General Description When placing an order, indicate the full product name. Please specify the quantity, valve model number, size, type of seal, Grade “E” EPDM, and part number from the following list. ValveValve SizePart Number 2"59-590-0-020 21/2"59-590-0-025 76.1mm59-590-0-076 3"59-590-0-030 4"59-590-0-040 139.7mm59-590-0-139 5"59-590-0-050 165.1mm59-590-0-165 6"59-590-0-060 8"59-590-0-080 10"59-590-0-100 12"59-590-0-120 Ordering Procedure Products manufactured by Tyco Fire Products are warranted solely to the original Buyer for ten (10) years against defects in material and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by Tyco Fire Products. No warranty is given for products or components manufactured by companies not affiliated by ownership with Tyco Fire Products or for products and components which have been subject to misuse, improper installation, corrosion, or which have not been installed, maintained, modified or repaired in accordance with applicable Standards of the National Fire Protection Association (NFPA), and/or the standards of any other Authorities Having Jurisdiction. Materials found by Tyco Fire Products to be defective shall be either repaired or replaced, at Tyco Fire Products’ sole option. Tyco Fire Products neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of products. Tyco Fire Products shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer’s representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CONTRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THEORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LABOR CHARGES, REGARDLESS OF WHETHER TYCO FIRE PRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT SHALL TYCO FIRE PRODUCTS’ LIABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. THE FOREGOING WARRANTY IS MADE IN LIEU OF ANY AND ALL OTHER WARRANTIES EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. Limited Wa rranty See Fire Protection Submittal Sheet for Pressure Rating and Listing/Approval Information Technical Data Tyco Fire Products, valves, accessories and other products are available throughout the U.S., Canada, and internationally, through a network of distribution centers. You may write directly or call 215-362-0700 for the distributor nearest you. General Notes: It is the Designer’s responsibility to select products suitable for the intended service and to ensure that pressure ratings and performance data is not exceeded. Always read and understand the installation instructions (IH-1000). Never remove any piping component or correct or modify any piping deficiencies without first depressurizing and draining the system. Material and gasket selection should be verified to be compatible for the specific application.Certified Company TYCO FIRE PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19946 Printed U.S.A. Page 2 of 2 TFP1550 Model CV-1F Check Valve 2. 5 " ( 7 3 . 0 m m ) , 7 6 . 1 m m 4" ( 1 1 4 . 3 m m ) 165 . 1 m m , 6 " ( 1 6 8 . 3 m m ) 8" ( 2 1 9 . 1 m m ) 3" ( 8 8 . 9 m m ) 10 0 0 0 50 0 0 40 0 0 30 0 0 20 0 0 10 0 0 50 0 40 0 30 0 20 0 10 0 5040302010 0.1 0.2 0.3 0.5 0.4 1 2 3 4 5 139 . 7 m m , 5 " ( 1 4 1 . 3 m m ) 37 8 4 8 18 9 2 4 15 1 3 9 . 2 11 3 5 4 . 4 75 6 9 . 6 37 8 4 . 8 18 9 2 . 4 15 1 3 . 9 11 3 5 . 5 75 7 . 0 37 8 . 5 18 9 . 2 15 1 . 4 11 3 . 5 75 . 7 37 . 8 FLOW RATE (LPM) PR E S S U R E D R O P I N P S I FLOW RATE (GPM) 2" ( 6 0 . 3 m m ) 10" ( 2 7 3 . 0 m m ) 12" ( 3 2 3 . 9 m m ) Note: It is good piping practice to apply a safety factor of 15% to 20% to the values in the above table for design purposes. 1 4 16 15 3 2 17 18 13 15 16 14 6 10 8 5 11 12 7 9 DetailPartMaterialQty. 1 BodyDuctile Iron1 2 CapDuctile Iron1 3 GasketSynthetic Fiber1 4 Hex Cap ScrewSteel, Zinc PlatedAR 5 ClapperStainless Steel or1 Ductile Iron 6 Seal FacingEPDM Grade “E”1 7 SpringStainless Steel1 8 Hinge ShaftStainless Steel1 9 Retaining RingStainless SteelAR 10WasherTeflon2 11Retention BoltStainless Steel1 12Seal RingNeoprene1 13Retaining DiscStainless Steel1 14LocknutStainless Steel1 15Plug-1⁄2"-14 NPTCast Iron2 16AdhesiveThread SealerAR 17NameplateAluminum1 18RivetSteel2 Nominal DimensionsApprox. SizeABCDEFJCoverWeight InchesInchesInchesInchesInchesInchesInchesInchesBolt Torq.lbs. mmmmmmmmmmmmmmmmLb.-ft./NmKg. 2"6.754.382.552.573.254.751.62159.0 60.3171.5111.364.865.382.3120.741.5214.5 21/2"8.005.803.413.403.886.001.703910.0 73.0203.2147.386.686.498.6152.443.2544.5 8.005.803.413.403.886.001.703910.00 203.2147.386.686.498.6152.443.2544.5 3"8.375.763.603.403.886.001.703911.0 88.9212.61.46.391.486.498.6152.443.2545.0 4"9.636.744.613.634.567.131.843925.0 114.3244.6171.2117.192.2115.1181.146.75411.3 10.507.505.294.204.907.601.903929.0 266.7190.5134.4106.7124.5193.048.35413.2 5"10.507.505.294.204.907.601.903929.0 141.3266.7190.5134.4106.7124.5193.048.35413.2 11.5080.55.754.505.007.601.486047.0 292.1204.5146.1114.3127.0193.037.68221.3 6"11.508.055.754.505.007.601.486047.0 168.3292.1204.5146.1114.3127.0193.037.68221.3 8"14.0010.257.755.625.458.402.2012066.0 219.1355.6260.4196.9142.7138.4213.458.916429.9 10"18.0013.0010.216.387.5010.503.00120109.7 273.0457.2330.2259.3162.1190.5266.776.216449.4 12"21.014.2811.317.267.6210.622.75120151.0 323.9533.4362.7287.2184.4193.5269.769.916468.0 76.1mm 139.7mm 165.1mm Care and Maintenance The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in accordance with the applicable standards of the National Fire Protection Association (e.g., NFPA 25), in addition to the standards of any authority having jurisdiction. The installing contractor or product manufacturer should be contacted relative to any questions. Any impairment must be immediately corrected. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service. Caps The breakaway Caps for the protection of the 21⁄2" inlets on the Fire Department Connection are supplied in heavy-duty plastic or cast aluminum alloy. They can be easily attached to the swivel lugs of the Fire Department Connection using the eye bolts supplied with the Caps. Manufactured by: Central Sprinkler Company 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 10-88 Fire Dept. Connection The Model 86A (straight pattern) and Model 86B (90° pattern) Fire Department Connections (FDC) are 21⁄2" x 21⁄2" x 4" single clapper siamese-type connections. They are designed to provide a supplementary water supply connection for automatic sprinkler systems of all types, as required by NFPA 13. Both straight and 90° pattern Fire Department Connections are cast brass with brass clapper, brass swivel couplings, and a brass hinge pin. The words “AUTO SPKR” and “F.D. Conn.” are cast in raised letters on the body of the Fire Department Connection. The clapper design allows for one or both inlets to be pressurized during operation. Fire Department Connections are generally installed 18" to 5' above finished grade, however local codes and standards may contain special requirements with regard to specific location. Wall Plates The Wall Plates are constructed of corrosion resistant aluminum alloy with cast-in raised letters. The raised letters on the round Wall Plate are “AUTO. SPKR.” and “FIRE DEPT. CONNECTION.” Model: 86A (straight pattern FDC) 86B (90o pattern FDC) Size: Outlet - 4" (102 mm) N.P.T. Inlets - 21⁄2" (64 mm) N.H. Std. thread Approvals: U.L., F.M. Maximum Working Pressure: 300 psi Standard Finish: FDC - Rough brass Wall Plates - Red enamel paint with raised letters painted white Caps - Red plastic or red enamel paint Weight: FDC (straight) - 7.8 lbs. (3.5 kg) FDC (90°) - 9.3 lbs. (4.2 kg) Wall plate - 11 oz. (312 grams) Cap - 3 oz. (85 grams) Mfgr. source: Non-domestic Dimensions: Wall Plate - 93⁄4" (248 mm) O.D. Straight or 90° Fire Dept. Connection Technical Data Product Description 86A & 86B 86A 86B With wall plates and breakaway caps No. 28-7.0 ©1988 Central Sprinkler Company Printed in U.S.A. The straight pattern Fire Department Connection is installed by attaching to a horizontal 4" N.P.T. threaded pipe generally extending through an exterior building wall. The 90o pattern Fire Department Connection is installed by attaching to a vertical 4" N.P.T. threaded pipe, generally freestanding in a yard application. The swivel inlets are 2.5"-7.5 American National Fire Hose Connection Screw Thread per NFPA 1963. The breakaway Caps for the inlets are used to prevent damage to the threads and to keep foreign objects from entering the fire department connection piping. Caps should be replaced after Fire Department Connection use or if the Caps are damaged or missing. Care & Maintenance All Fire Department Connections should be regularly inspected to insure proper working condition. 1. Connections should be readily visible and accessible. They should not be obstructed by vegetation or equipment. 2. Caps should be in place and the 21⁄2" swivels should enjoy freedom of movement. Hose threads should be clean and in good condition. 3. Verify that the check valve in the fire department connection piping is not leaking. Cap - Breakaway Ordering Information Installation When placing an order, indicate the full product name. Please specify the quantity, model, and size. Fire Department Connections are not furnished with wall plates and caps. They must be ordered separately. Availability and Service: Central sprinklers, accessories, and other products are available throughout the U.S. and Canada, and internationally through a network of Central Sprinkler distribution centers. You may write directly to Central Sprinkler Company, or call (215) 362-0700 for the distributor nearest you. Guarantee: Central Sprinkler Company will repair and/or replace any products found to be defective in material or workmanship within a period of one year from date of shipment. Please refer to the current Price List for further details of the warranty. Conversion Table: 1 inch = 25.400 mm 1 foot = 0.3048 M 1 pound = 0.4536 kg Conversions are approximate. Wall Plate - Round Central Sprinkler Company 451 N. Cannon Avenue, Lansdale, PA 19446 Phone (215) 362-0700 FAX (215) 362-5385 86.0 Identification Signs For Sprinkler Systems and Devices NFPA 13 Signing Requirements Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 Page of 4 AUGUST, 2007 TFP65 WARNINGS The Identification Signs described herein must be installed and main- tained in compliance with this docu- ment, as well as with the applicable standards of the National Fire Pro- tection Association, in addition to the standards of any other authorities hav- ing jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Technical Data Material & Finish 18 gauge aluminum with mylar facing. Installation The Identification Signs are provid- ed with 1⁄8 Inch (3,2 mm) diameter or larger holes (or slots) in the corners for easy attachment using standard hard- ware chain, wire, plastic lock ties, or light gauge metal strap (not included). General Description Identification Signs (Ref. Figure 1) are designed to provide information to the end user about the sprinkler system and its components. They are avail- able with a variety of wording combi- nations to meet the signing require- ments of NFPA 13. The five basic types of Identification Signs are as follows: Type A- Control Valve Sign Type B- Multi-Purpose Text Signs (See Below) Type D- Fire Alarm Sign Type E- Hydraulic Calculation Sign Type B- Identification Signs are avail- able with the following text options: AIR CONTROL AIR LINE ALARM TEST ANTIFREEZE SYSTEM AUXILIARY DRAIN CONTROL VALVE DRAIN DRAIN VALVE INSPECTORS TEST MAIN CONTROL MAIN DRAIN Care and Maintenance The following inspection procedure must be performed as indicated, in ad- dition to any specific requirements of the NFPA, and any impairments must be immediately corrected. The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and devic- es in compliance with this document, as well as with the applicable stan- dards of the National Fire Protection Association (e.g., NFPA 25), in addition to the standards of any authority hav- ing jurisdiction. The installing contrac- tor or product manufacturer should be contacted relative to any questions. It is recommended that automatic sprin- kler systems be inspected, tested, and maintained by a qualified Inspection Service in accordance with local re- quirements and/or national codes. After placing a fire protection system in service, notify the proper authorities and advise those responsible for mon- itoring proprietary and/or central sta- tion alarms. INSPECTION PROCEDURE Annual visual inspections are recom- mended to ensure that Identification Signs are properly located. Width x Height Inches (mm) Type A 9 x 7 (229 x 178) Type B 6 x 2 (152 x 51) Type C 7¾ x 1¼(197 x 32) Type D 9 x 7 (229 x 178) Type E 5 x 7 (127 x 178) Page 2 of 4 TFP65 SIGN- type B, AvAI l ABle WIth the FolloWING text optIoNS “AIR CONTROL” .........................P/N 2328 “AIR LINE” ..............................P/N 2302 “ALARM TEST” ........................P/N 2304A “ANTIFREEZE SYSTEM” ..................P/N 2306 “AUXILIARY DRAIN”. . . . . . . . . . . . . . . . . . . . . .P/N 2307 “CONTROL VALVE” ......................P/N 2310 “DRAIN” ...............................P/N 2311 “DRAIN VALVE” .........................P/N 2327 “INSPECTORS TEST” ....................P/N 2313 “MAIN CONTROL” .......................P/N 2319 “MAIN DRAIN” ..........................P/N 2320 SIGN- type e, p/N 2317 SIGN- type D RectANGul AR 6-1/2” x 8-1/2”, p/N 2316 oR RouND 7-1/4” DIAmeteR , p/N 2329 SIGN- type A , p/N 2300A FIGuRe 1 IDeNtIFIcAtIoN S IGNS TFP65 Page of 4 Limited Warranty Products manufactured by Tyco Fire & Building Products (TFBP) are war- ranted solely to the original Buyer for ten (10) years against defects in mate- rial and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by TFBP. No warran- ty is given for products or components manufactured by companies not af- filiated by ownership with TFBP or for products and components which have been subject to misuse, improper in- stallation, corrosion, or which have not been installed, maintained, modified or repaired in accordance with applicable Standards of the National Fire Protec- tion Association, and/or the standards of any other Authorities Having Juris- diction. Materials found by TFBP to be defective shall be either repaired or re- placed, at TFBP’s sole option. TFBP neither assumes, nor authorizes any person to assume for it, any other ob- ligation in connection with the sale of products or parts of products. TFBP shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer’s representatives. In no event shall TFBP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, indirect, special or consequential dam- ages, including but not limited to labor charges, regardless of whether TFBP was informed about the possibility of such damages, and in no event shall TFBP’s liability exceed an amount equal to the sales price. The foregoing warranty is made in lieu of any and all other warranties, ex- press or implied, including warranties of merchantability and fitness for a particular purpose. This limited warranty sets forth the ex- clusive remedy for claims based on failure of or defect in products, materi- als or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full ex- tent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. Ordering Procedure Orders must include the description and Part Number (P/N). Contact your local distributor for availability. Hardware for hanging is not sup- plied with the Sign. It must be ordered separately. Identification Signs, (Types A, C, D, or E) Specify: Type (A, C, D, or E) Identification Sign, P/N (specify). Identification Signs (Type B) Specify: Type B Identification Sign in- scribed (specify, e.g. “AIR CONTROL”), P/N (specify). Type A ..........................P/N 2300A Type D (Round) ....................P/N 2329 Type D (Rectangle) .................P/N 2316 Type E ...........................P/N 2317 Type B “AIR CONTROL” ...................P/N 2328 “AIR LINE” ........................P/N 2302 “ALARM TEST” ...................P/N 2304A “ANTIFREEZE SYSTEM” ............P/N 2306 “AUXILIARY DRAIN”. . . . . . . . . . . . . . . . P/N 2307 “CONTROL VALVE” ................P/N 2310 “DRAIN” .........................P/N 2311 “DRAIN VALVE” ...................P/N 2327 “INSPECTORS TEST” ..............P/N 2313 “MAIN CONTROL” .................P/N 2319 “MAIN DRAIN” ....................P/N 2320 Page 4 of 4 TFP65 TYCO FIRE & BUILDING PRODUCTS, 451 North Cannon Avenue, Lansdale Pennsylvania 19446 Sprinkler Cabinets 3, 6, & 12 Sprinklers, 1/2 or 3/4 Inch NPT 6 ESFR Sprinklers, 3/4 or 1 Inch NPT Page of 4 AUGUST, 2007 TFP785 Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 General Description Tyco® Sprinkler Cabinets are con- structed of metal enclosures with hinged covers designed to provide on- site storage of an emergency supply of sprinklers and a sprinkler wrench. NFPA 13 requires a representative number of each type of sprinkler used in a sprinkler system to be stored in a cabinet on-site to allow for immediate removal and replacement of sprinklers that may have operated or become damaged. Sprinkler Cabinets are manufactured of heavy gauge steel with knock-outs to accommodate NPT threaded sprin- klers and are painted an attractive red enamel. WARNINGS The Sprinkler Cabinets described here- in must be installed and maintained in compliance with this document, as well as with the applicable standards of the National Fire Protection Asso- ciation, in addition to the standards of any other authorities having jurisdic- tion. Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Technical Data Material Carbon Steel Weights 3 Sprinkler Cabinet ............. . . . . . . . . . . . . . . . . .1.5 Lbs. (0,68 kg) 6 Sprinkler Cabinet .............. . . . . . . . . . . . . . . . . .2.3 Lbs. (1,04 kg) 12 Sprinkler Cabinet ............. . . . . . . . . . . . . . . . . .4.0 Lbs. (1,81 kg) 6 ESFR Sprinkler Cabinet ......... . . . . . . . . . . . . . . . . .3.3 Lbs. (1,36 kg) Page 2 of 4 TFP785 5-1/4"R (133,4 mm) DOOR SWING MINIMUM CLEARANCE 6"(150 mm) 2-9/16" (65,1 mm) HOLES ACCOMMODATE (127,0 mm)(25,4 mm) SCREWS 3/16"(5 mm) HOLES FOR 2"1-3/16" (50,8 mm) 1"5" (30,2 mm) (127,0 mm) 5" (184,2 mm) 7-1/4"1-1/4" (31,8 mm) REMOVE KNOCKOUTS 3/4"NPT SPRINKLERS TO ACCOMMODATE 1/2"NPT SPRINKLERS 1-3/4" (44,5 mm) (98,4 mm) 3-1/4"2-5/8" (66,7 mm) 1-1/8" (28,6 mm) 1"(25,4 mm) STRAP HANGER SLOTS FORSPRINKLER SHELF WRENCH SHELF 1-5/16" (33,3 mm) HINGES DOOR NOT SHOWN AND HINGES 1-3/4" (44,5 mm) (152,4 mm)3-1/4" (98,4 mm) 10-13/16" (274,6 mm) 6" 14-1/16" (357,2 mm) (30,2 mm) (127,0 mm)1" (25,4 mm) 5" 1-5/8" 1-3/16" (41,3 mm) (31,8 mm) 1-1/4" TO ACCOMMODATE 3/4"NPT SPRINKLERS REMOVE KNOCKOUTS 1/2"NPT SPRINKLERS (33,3 mm) 1-5/16" HOLES ACCOMMODATE MINIMUM 6"(150 mm) CLEARANCE (65,1 mm) 2-9/16" DOOR SWING (133,4 mm) 5-1/4"R (50,8 mm) 2" SHELF WRENCHHOLESFOR 3/16"(5 mm) SCREWS SPRINKLER SLOTS FOR STRAP HANGER 1"(25,4 mm)SHELF HINGES DOOR NOT SHOWN AND HINGES FIGuRe 1 3 SpRINkleR CAbIN et FIGuRe 2 6 SpRINkleR CAbIN et TFP785 Page of 4 (127,0 mm) HOLES ACCOMMODATE 1-3/4"(25,4 mm) SCREWS 3/16"(5 mm) HOLES FOR (44,5 mm) 1"(25,4 mm) STRAP HANGER SLOTS FORSPRINKLER SHELF WRENCH SHELF 1-1/2" (98,4 mm) 3-1/4"6"2"1-3/16" (152,4 mm)(50,8 mm) 1"5" (30,2 mm) (274,6 mm) 10-13/16" (357,2 mm) 14-1/16" (41,3 mm) 1-5/8" 1-1/8" (28,6 mm) (38,1 mm) REMOVE KNOCKOUTS 3/4"NPT SPRINKLERS TO ACCOMMODATE 1/2"NPT SPRINKLERS 5-1/4"R 4-1/8"MINIMUM CLEARANCE (104,8 mm) 6"(150 mm) DOOR SWING (133,4 mm) 1-1/2" (38,1 mm)HINGES DOOR NOT SHOWN AND HINGES (357,2 mm) 14-1/16" (274,6 mm) 10-13/16" (157,2 mm) 6-3/16" MINIMUM 7"(180 mm) (152,4 mm) 6" (39,7 mm) 1-9/16" 2" (50,8 mm) 1-5/8" (41,3 mm) (96,8 mm) 3-13/16" (60,3 mm) 2-3/8" CLEARANCE DOOR SWING (163,5 mm) 6-7/16"R 1-3/16" (30,2 mm) (25,4 mm) 1" 3/4"NPT SPRINKLERS HOLES ACCOMMODATETOACCOMMODATE REMOVE KNOCKOUTS 1"NPT SPRINKLERS 3-1/8" (79,4 mm) DOOR AND HINGES SLOTS FOR STRAP HANGER 1"(25,4 mm)3/16"(5 mm) HOLES FOR SCREWS SHELF WRENCH SHELF SPRINKLER HINGES (39,7 mm) 1-9/16" NOT SHOWN FIGuRe 3 12 SpRINkleR CAbINet FIGuRe 4 6 eSFR SpRINkleR CAbINet Page 4 of 4 TFP785 TYCO FIRE & BUILDING PRODUCTS, 451 North Cannon Avenue, Lansdale Pennsylvania 19446 Installation Sprinkler Cabinets are designed with two 3/16 Inch (4,7 mm) diameter holes for wall mounting or direct attachment to the system riser with a strap-type hanger. The Sprinkler Cabinet should be installed at or near the system con- trol valve and must be stocked with an adequate supply of spare sprinklers and a sprinkler wrench. The stock of spare sprinklers should include sprinklers of each type and temperature rating as are installed in the sprinkler system, in the following quantities: Sprinklers In System Spare Sprinklers Required Under 300 6 300-1000 12 Over 1000 24 The 3, 6, and 12 Sprinkler Cabinets are designed to accept both 1/2 & 3/4 Inch NPT threaded sprinklers, where- as the 6 ESFR Sprinkler Cabinets are designed to accept both 3/4 & 1 Inch NPT threaded sprinklers. As neces- sary, insert a screwdriver blade from the front top of the shelf and under the near bottom part of the knockout an- nular ring. Press the screwdriver han- dle down to remove the knockout ring. Care and Maintenance The Sprinkler Cabinet, wrench, and stock of spare sprinklers should be in- spected at least quarterly. The follow- ing items should be checked: • The Sprinkler Cabinet should be readily accessible, and not exposed to a corrosive atmosphere or tem- peratures in excess of 100°F (38°C). • The stock of spare sprinklers should include an adequate number of each type and temperature rating. • The stock of sprinklers must be in good condition. • A sprinkler wrench of the appropriate type must be included in the Sprin- kler Cabinet. Limited Warranty Products manufactured by Tyco Fire & Building Products (TFBP) are war- ranted solely to the original Buyer for ten (10) years against defects in mate- rial and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by TFBP. No warran- ty is given for products or components manufactured by companies not af- filiated by ownership with TFBP or for products and components which have been subject to misuse, improper in- stallation, corrosion, or which have not been installed, maintained, modified or repaired in accordance with applicable Standards of the National Fire Protec- tion Association, and/or the standards of any other Authorities Having Juris- diction. Materials found by TFBP to be defective shall be either repaired or re- placed, at TFBP’s sole option. TFBP neither assumes, nor authorizes any person to assume for it, any other ob- ligation in connection with the sale of products or parts of products. TFBP shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer’s representatives. In no event shall TFBP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, indirect, special or consequential dam- ages, including but not limited to labor charges, regardless of whether TFBP was informed about the possibility of such damages, and in no event shall TFBP’s liability exceed an amount equal to the sales price. The foregoing warranty is made in lieu of any and all other warranties, ex- press or implied, including warranties of merchantability and fitness for a particular purpose. This limited warranty sets forth the ex- clusive remedy for claims based on failure of or defect in products, materi- als or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full ex- tent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. Ordering Procedure When placing an order, indicate the full product name. Contact your local dis- tributor for availability. Sprinkler Cabinet: Specify: (Description), P/N (specify). 3 Sprinkler Cabinet. . . . . . . . . . . . . . . . . P/N 1177 6 Sprinkler Cabinet. . . . . . . . . . . . . . . . . P/N 1119 12 Sprinkler Cabinet ................P/N 1124 6 ESFR Sprinkler Cabinet ........... P/N 1111