Loading...
HomeMy WebLinkAboutB12-0572� Community Development Department 75 South Frontage Road Vail, Colorado USA 81657 CERTIFICATE OF OCCUPANCY This certificate is issued pursuant to the requirements of Title 10, Section 10-1-2, ADOPTED CODES of the Vail Town Code certifying that, at the time of issuance, this structure was found to be substantially in compliance with the various ordinances ofthe town regulating building construction or use for the following: Name and description ofproject Solaris Retail Suite 103 Address ofproject: 141 East Meadow Drive Vail, Colorado 81657 Owner name and address Solaris Commercial Owner LLC Vail Co. 81657 IBC Edition: 2009 Occupancy Group(s): M Type(s) of Construction: IA Permit Number(s): B12-0572 Occupant Load:_ Sprinkler System Y/ N Type:_13 ��� December 14, 2012 Martin Haeberle, ChiefBuilding Official Date NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES M OF . Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657 p. 970.479.2139, f. 970.479.2452, inpsections 970.479.2149 COMBINATION BLDG PERMIT Permit #: B12 -0572 Project #: PRJ12 -0674 Job Address: 141 E MEADOW DR VAIL Location......: SOLARIS RETAIL UNIT 103 Parcel No....: 210108293001 OWNER SOLARIS COMMERCIAL OWNER LLC 10/24/2012 141 E MEADOW DR 211 VAIL, CO 81657 APPLICANT SOLARIS COMMERCIAL OWNER LLC 10/24/2012 141 E MEADOW DR 211 VAIL, CO 81657 CONTRACTOR SOLARIS PROPERTY OWNER, LLC 11/06/2012 141 EAST MEADOW DRIVE, SUITE 211 VAIL CO 81657 License: C000003177 Description: T.I. OF UNIT 103 Applied.....: 10/24/2012 Issued...: 11/06/2012 Phone: 970 - 479 -7566 Payments ------------------------------- > $5,230.53 BALANCE DUE ------------------------ > $0.00 * *� DECLARATIONS I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the town's zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY -FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8:00 AM - 4:00 PM. combination permit_012811 Type Construction: Valuation: $94,272.75 Occupancy: p Y� «....,,._. FEE SUMMARY .....,,..,........,« � ............................... ...,......,.......... Use Tax Fee------------ -- - ------ > $1,685.46 Building Permit - - - -- > $958.75 Bldg Plan Check ----- - - - 9 - -> $623.19 > $560.63 Restuarant Plan Review--- - - - - -> $0.00 Electrical Permit ---- - - - - -> $862.50 Elec Plan Check $420.00 Mech Plan Check ---- - - - - -> $ 105.00 Additional Fees------- ---- --- -- - ---> $0.00 $0.00 Mechanical Permit - - - - - -> $0.00 Plmb Plan Check -- - - - - -- $0.00 Recreation Fee-------- ------ - - - ---> $0.00 Plumbing Permit --- - - - - -> Investigation---------- --- ---- - - - -- -> $15.00 Will Call - - - - - -- > TOTAL PERMIT FEES--------- - -- - -> $5,230.53 Payments ------------------------------- > $5,230.53 BALANCE DUE ------------------------ > $0.00 * *� DECLARATIONS I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the town's zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY -FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8:00 AM - 4:00 PM. combination permit_012811 xxxxxrxxrxxrrrxrrxxxxxxxxxxxxrxxrxxxxrxxrxrxxrxrxrrxxxxxxrxrx rxxrxx *xxxxrxxrx CONDITIONS OF APPROVAL TO BE MET PRIOR TO FINAL SIGN OFF Permit #: B12 -0572 Owner: SOLARIS COMMERCIAL OWNER LLC Address: 141 E MEADOW DR VAIL SOLARIS RETAIL UNIT 103 . xxxxxxxxxxxxxxxxxxrxxxxxxrxrxrrxxxxxrx ,.._____ Location: Cond: 1 (FIRE): FIRE DEPARTMENT APPROVAL IS REQUIRED BEFORE ANY WORK CAN BE STARTED. Cond: CON0012906 fire alarm and sprinkler changes shall require separate permits ,mbination permit-012811 REQUIRED INSPECTIONS AND STATUSES Permit*: B12 -0572 Owner: SOLARIS COMMERCIAL OWNER LLC Address: 141 E MEADOW DR VAIL SOLARIS RETAIL UNIT 103 Location: Item: 00120 ELEC - Rough Item: 00200 MECH -Rough Item: 00030 BLDG - Framing Item: 00060 BLDG - Sheetrock Nail Item: 00190 ELEC -Final Item: 00390 MECH -Final Item: 00090 BLDG -Final mbination permit-012811 • r. 15�1'2 . f �' 613 12 -12 -2012 Inspection Re 'duest Reporting M Page 19 4:24 Dm Vail CCU - [_itv C)# ILJIL��z _ /I C„7�- Requested Inspect Date Site Address A/P /D Information Activity: B12 -0572 Type: COMBO Const Type: Occupancy: Owner: SOLARIS COMMERCIAL OWNER LLC Contractor: SOLARIS PROPERTY OWNER, LLC Description: T.I. OF UNIT 103 Reauested Insuection(s Item: 90 BLDG- final Requestor: Assigned To G Action: k Time Exp: Item: 190 ELEC -Final Requestor: Assigned To S Action: Time Exp: Comment: Meter release Item: 390 MEC F' al Requestor: 200 MECH -Rough Assigned To: SG Action: Time Exp: Inspection Histo Thursday, December 13, 2012 141 E MEADOW DR VAIL SOLARIS RETAIL UNIT 103 06 4 (al' b Sub Type: ACOM Use: Phone: 970 - 479 -7566 Status: ISSUED Insp Area: Requested Time: 09:30 AM Phone: Entered By: MHAEBERLE K Requested Time: 08:30 AM Phone: Entered By: MHAEBERLE K Requested Time: 09:00 AM Phone: Entered By: MHAEBERLE K Item: 120 ELEC -Rou h ** Approved'' 11/30/12 Inspector: sgremmer Action: AP APPROVED Comment: 12/06/12 Inspector: sgremmer Action: AP APPROVED Comment: Meter release Item: 200 MECH -Rough ** Approved 12/03112" Inspector: sgremmer Action: AP APPROVED Comment: Item: 30 BLDG - Framing ** Approved ** 12/03/12 Inspector: sgremmer Action: AP APPROVED Comment: Item: 60 BLDG - Sheetrock Nail ** Approved ** 12/05/12 Inspector: sgremer Action: AP APPROVED Comment: Item: 190 ELEC -Final Item: 390 MECH -Final Item: 90 BLDG -Final REPT131 Run Id: 15035 ((:j� TOWr,J OF VAIL Department of Community Development 75 South Frontage Road Vail, CO 81657 Tel: 970 - 479 -2128 www.vailgov.com Development Review Coordinator BUILDING PERMIT APPLICATION (Separate applications are required for alarm & sprinkler) Project Street Address: 141 East Meadow Drive 103 (Number) (Street) Building /Complex Name: Solaris Contractor Information Business Name: Solaris Property Owner (Suite #) Business Address: 141 East Meadow Drive Suite 211 City Vail Contact Name: Sharon Cohn Contact Phone: 303 - 550 -4551 State: CO Zip: 81657 Contact E -Mail: sharon @solarisvail.com I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the town's zoning and subdivision codes, design review ap- proved, International Building and Residential Codes and other ordinances of the Town applicable thereto. X Owner /Owner's Representative Signature (Required) Applicant Information Applicant Name: Sharon Cohn (SPO) Applicant Phone: 303 -550 -4551 Applicant E -Mail: sharon@solarisvaii.com Project Information Owner Name: Solaris Commercial Owner Parcel #: 210108293001 (For Parcel #, contact Eagle County Assessors Office at (970- 328 -8640 or visit www.eaglecou nty. uslpatie) For Office Use Only: Fee Paid: + cold .� Received From: Z� a Cash Check # c CC: Visa / MC Last 4 CC # exp date: i(� ( 5 Auth # ' f f ii- Project #: r 9 1 0a— n (D/ q D R B #: Ii-- l'� Building Permit #: � lA ` Dc[ J I, Lot #: P Block #_5J) Subdivision: yiiiL UILt." E Work Class: New t(D Addition 0 Alteration (0 Type of Building: Single - Family 0 Duplex 0 Multi- Family (0 Commercial (Oj Other 0 Work Type: Interior Q Exterior 0 Both 0 Work Included Plans Included Valuation of Work Electrical (Qi Yes O)No OYes QNo 25710.75 Mechanical OYes O)No OYes ONo 20949.50 Plumbing 0Yes (�)No OYes oNo 0 Building G)Yes (DNo (i)Yes OjNo 47612.50 Value of all work being performed: $ (value based on IBC Section 109.3 & IRC Section 108.3) 94272.75 Electrical Square Footage Detailed Scope and Location of Work: Suite 103- Solaris Tenant Improvement (use additional sheet if necessary) Date Received: D FE C FE OCT 2 3 ZO'IZ TOWN OF VAIL 12 -Mar -2012 October 22, 2012 Mr. Martin Haeberle Chief Building Official Town of Vail 75 South Frontage Road Vail, CO 81657 RE: Tenant Improvement Plans Submittal for Retail Suite 103 — Project Address: Suite 103, 141 E. Meadow Drive, Vail CO 81657 Dear Mr. Haeberle, We are pleased to transmit with this letter the Suite 103 Tenant Improvement Plans for Building Permit. Suite 103 is a retail store and is located on the western side of the retail area adjacent to Cinebistro on Level 1. Included with this letter are: 1. One Building Permit Application Form. 2. Three full -size stamped and signed Plans, with a cover date of 10/19/2012. 3. Three COMcheck Interior Lighting and Power Compliance Certificates dated 10/17/2012 Please communicate all TOV Plan Review comments to Mike Suman of Suman Architects at michael@sumanarchitects.com and Sharon Cohn of One Willow Bridge Commercial, LLC at sharon@solarisvail.com. Please call Sharon Cohn at 303 -550 -4551 with any questions. Sincerely, z;�tvT—� Sharon Cohn Solaris Property Owner COMcheck Software Version 3.9.1 Interior Lighting and Power Compliance Certificate 90.1 (2007) Standard Section 1: Project Information Project Type: New Construction Project Title : Solaris suite 103 Construction Site: Owner /Agent: 141 East Meadow Drive Vail, CO 81657 Section 2: Interior Lighting and Power Calculation A Area Category Retail:Sales Area Allowance: Furniture, clothing, cosmetics highlighting / Fix. ID: Track lighting 1 Allowance: Furniture, clothing, cosmetics highlighting / Fix. ID: D2 Allowance: Furniture, clothing, cosmetics highlighting / Fix. ID: D1 Designer /Contracts B C D Floor Area Allowed Allowed Watts (ft2) Watts / ft2 (B x C) 1460 1.7 2482 1000(a) 2.6 2600(b) 260(a) 2.6 676(b) 200(a) 2.6 156(b) Supplemental Allowed Watts(c) = 782 (a) Area claimed must not exceed the illuminated area permitted for this allowance type. Total Allowed Watts = 6696 (b) Allowance is (B x C) or the actual wattage of the fixtures given in Section 2, whichever is less. (c) Supplemental wafts must be associated with retail merchandise highlighting fixtures. Supplemental watts are not included calculation of lighting complaince percentage. (e) Additional controls /switching allowances are based on number of fixtures or wattage controlled, not floor area of allowance. Section 3: Interior Lighting Fixture Schedule A Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast Retail:Sales Area (1460 sq.ft.) Track lighting 1: Wattage based on 179.0 feet of track HID 1: D2: Ceramic Metal Halide 39W / Pulse start HID 2: D1: Ceramic Metal Halide 39W / Pulse start Section 4: Requirements Checklist Lighting Wattage: 0 1. Total proposed watts must be less than or equal to total allowed watts. B C D E Lamps/ # of Fixture (C X D) Fixture Fixtures Watt. 0 0 0 5370 2 15 78 1170 1 4 39 156 Total Proposed Watts = 6696 Allowed Watts Proposed Watts Complies 6696 6696 Passes using retail merchandise highlighting supplemental watts. 0 2. Exit signs 5 Watts or less per sign. Controls, Switching, and Wiring: ® 3. Independent manual or occupancy sensing controls for each space (remote switch with indicator allowed for safety or security). Project Title: Solaris suite 103 Data filename: J: \2351.00 - Solaris Unit #103 \Ltg Calcs \235100 - COMcheck.cck Report date: 10/17/12 Page 1 of 2 ❑ 4. Occupant sensing control in class rooms, conference /meeting rooms, and employee lunch and break rooms. Exceptions: ❑ Spaces with multi -scene control; shop classrooms, laboratory classrooms, and preschool through 12th grade classrooms. ❑ 5. Automatic shutoff control for lighting in >5000 sq.ft buildings by time -of -day device, occupant sensor, or other automatic control. Exceptions: ❑ 24 hour operation lighting, patient care areas; where auto shutoff would endanger safety or security. ❑ 6. Master switch at entry to hotel /motel guest room. © 7. Separate control device for display /accent lighting, case lighting, task lighting, nonvisual lighting, lighting for sale, and demonstration lighting. ❑ 8. Tandem wired one -lamp and three -lamp ballasted luminaires (No single -lamp ballasts). Exceptions: ❑ Electronic high- frequency ballasts. P` •�.RFG►� F] Luminaires not on same switch. 0 • ' • •':sip ❑ Recessed luminaires 10 ft. apart or surface /pendant not continuous. r 3 n Luminaires on emergency circuits. 837 C Voltage Drop:'••.�n ��•IZ ?G•� ® 9. Feeder conductors have been designed for a maximum voltage drop of 2 percent. ss/ ••�` ® 10. Branch circuit conductors have been designed for a maximum voltage drop of 3 percent. SAL Ems' Section 5: Compliance Statement Compliance Statement: The proposed lighting design represented in this document is consistent with the building plans, specifications and other calculations submitted with this permit application. The proposed li hting system has been designed to meet the 90.1 (2007) Standard requirements in COMcheck Version 3.9.1 and to comply with the man r uirements in the Requirements Checklist. Jeff Mullikin, PE U j=am 10/18/2012 Name - Title Sign Date Section 5: Post Construction Compliance Statement Record Drawings and Operating and Maintenance Manuals: Li 1. Construction documents with record drawings and operating and maintenance manuals provided to the owner. Lighting Designer or Contractor Name Signature Date Project Title: Solaris suite 103 Report date: 10/17/12 Data filename: J: \2351.00 - Solaris Unit #103 \Ltg Calcs \235100 - COMcheck.cck Page 2 of 2