Jøtul F 3 USA
Installation and Operating Instructions for the USA and Canada 2
Exploded view 20
Kindly save these instructions for future reference.
Jø
t
u
l
F
3
US
A
Ma
n
u
a
l
V
e
r
s
i
o
n
P
1
1
2
Table of contents:
Standards and Safety Notices ...........................3
1.0 Installations ..................................................4
2.0 Chimney Requirements ...............................6
Masonry Chimney ........................................................................6
Prefabricated Chimney ...............................................................7
Chimney height ............................................................................7
Wall pass-throughs ......................................................................7
3.0 Connecting to the Chimney .........................8
Masonry chimneys .......................................................................8
Hearthmount/Fireplaces ............................................................8
Prefabricated Chimney ...............................................................9
4.0 Clearances ....................................................10
Floor requirements ......................................................................10
Wall shields ....................................................................................11
Stove Clearances ...........................................................................12
Alcove Installations ...........................................13
5.0 Operation .....................................................14
Controls ...........................................................................................14
Breaking in your new Stove .......................................................14
Starting/Maintaining ..................................................................15
Formation of Creosote ................................................................15
6.0 Maintenance ................................................16
Ash Removal ..................................................................................16
Glass Care .......................................................................................16
7.0 General Maintenance .............................17
Gaskets ............................................................................................17
8.0 Accessories .............................................18
Firescreen .......................................................................................18
Floor Bracket Kit............................................................................18
Stove -Top Thermometer ............................................................18
Appendix A (alternate floor protecion) ..............................19
Parts Diagram .......................................................................20
Part list..................................................................................21
Save these instructions and make them available to
anyone using or servicing the stove.
22
9
/
1
6
"
-
5
7
3
m
m
27
7
/
8
"
-
7
0
7
m
m
7 1/4"- 184 mm
19 " - 484mm
8
3
/
8
"
-
2
1
2
m
m
22
9
/
1
6
"
-
5
7
3
m
m
22 3/4" - 577 mm
7
1
/
4
"
-
1
8
4
m
m
14
7
/
1
6
"
-
3
6
7
m
m
USA/Canada
3
Installation and Operation Instructions for USA/Canada
Installation et fonctionnement pour Canada
Safety notice: If this solid fuel room heater is not properly installed, a house fire may result. For your
safety, follow the installation directions. Contact local building or fire officials about restrictions and
installation inspection requirements in your area. Save these instructions for future reference.
Avis de sécurité: Une installation non appropriée de ce poêle de chauffage risque de provoquer
un incendie. Assurez votre sécurité en respectant les directives d’installation suivantes. Consultez
les autorités locales du bâtiment ou de la prévention des incendies au sujet des restrictions et
exigences relatives aux inspections d’installations dans votre région.
Tested and listed by ITS, Intertek Testing Services, Middleton, Wisconsin.
Tested to U.S. Standards: ANSI/UL 737 andANSI/UL 1482, Canadian Standards: CAN/ULC-S627-M93
Standards
The Jøtul F 3 woodstove has been tested and listed to:
U.S. Standards: ANSI/UL 737 and ANSI/UL 1482
Canada: CAN/ULC-S627-M93
Tests performed by:
ITS, Intertek Testing Services, Middleton, WI
Manufactured by:
Jøtul AS., P.O. Box 1411, Fredrikstad, Norway
Distributed by:
Jøtul North America Inc, 55 Hutcherson Drive,
Gorham, Maine 04038, USA
This heater meets the U.S. Environment Protection
Agency’s Emissions limits for wood heaters manufactured
and sold after July 1, 1990.
Under specific test conditions, this heater has shown
heat output at rates ranging from 11,500 to 43,500 BTU’s
per hour.
The Jøtul F 3 woodstove is only listed to burn wood. Do
not burn any other fuels.
Read this entire manual before you install and use your
new room heater.
Save these instructions and make them available to
anyone using or servicing the stove.
Check Building Codes
When installing, operating and maintaining your Jøtul
F 3 woodstove, follow the guidelines presented in these
instructions, and make them available to anyone using or
servicing the stove.
Your city, town, county or province may require a building
permit to install a solid fuel burning appliance.
In the U.S., the National Fire Protection Association’s Code,
NFPA 211, Standards for Chimneys, Fireplaces, Vents and
Solid Fuel Burning Appliances, or similar regulations, may
apply to the installation of a solid fuel burning appliance
in your area.
In Canada, the guideline is established by the CSA
Standard, CAN/CSA-B365-M93, Installation Code for Solid-
Fuel-Burning Appliances and Equipment.
Always consult your local building inspector or authority
having jurisdiction to determine what regulations apply
in your area.
USA/Canada
Accepted For Use
City of New York
Department of Buildings
MEA 313-00-E
Jøtul North America, Inc.
4
Notices
• Be sure to read this entire manual before you install
or use your new Jøtul F 3.
• If this room heater is not properly installed, a house
fire may result. To reduce the risk of fire, follow the
installation instructions. Failure to follow these
instructions may result in property damage, bodily
injury, or even death.
• Jøtul recommends that you have your new Jøtul F
3 installed by a professional installer of solid fuel
burning appliances.
• Extremely hot while in operation! Keep children,
clothing and furniture away. Contact may cause skin
burns.
• Avoid creating a low pressure condition in the
room where the stove is operating. Be aware
that operation of an exhaust fan or clothes dryer
can create a low pressure area and consequently
promote flow reversal through the stove and
chimney system. The chimney and building,
however, always work together as a system -
provision of outside air, directly or indirectly to
an atmospherically vented appliance will not
guarantee proper chimney performance. Consult
your local Jøtul authorized dealer regarding
specific installation/performance issues.
• Do not use chemicals or fluids to start the fire. Some
fuels will, during combustion, separate carbon
monoxide and generate it in the burn chamber. Carbon
monoxide is toxic, so please follow the guidelines in
this manual for proper operation of your Jøtul F 3.
• If you for some reason experience smoke “roll-out” from
the stove, it may activate smoke detectors if installed
in the house.
Do not connect this stove to any air distribution duct or
system.
1.0 Installation
If this solid fuel room heater is not properly installed
a house fire may result. For your safety, follow the
installation directions. Contact the local building or fire
officials about restrictions and installation inspection
requirements in your area.
USA/Canada
Reminder:
Your local officials have final authority in determining if a
proposed installation is acceptable. Any requirement, that is
requested by the local authority having jurisdiction, that is
not specifically addressed in this manual, defaults to NFPA
211, and local codes.
In the U.S. or in Canada, CAN/CSA-B365-M and local
codes.
Installing the venting
The Jøtul F 3 can be vented from the top, the rear or from
either the right or left side. Follow the instructions below
for the desired venting location.
Top exit venting
When top exit venting is desired, use a 3mm allen wrench
to remove the two set screws that secure the top casting
to the sides of the stove and lift off the top casting. Lay
the top casting on a flat surface upside down and remove
the 10mm bolt from the traverse bar and remove the
smoke outlet cover.
Reinstall the top casting, be sure to secure with the two
set screws that were removed. See figure 1.
Rear exit venting
When rear exit venting is desired it will be necessary to
“knock-out” the vent hole from the rear casting.
Remove the top casting of the stove by removing the two
3mm set screws that secures the top to the sides. The set
screws are located on the outside of the stove on the top
of each side panel.
Using a 10mm wrench remove the double rear heatshields
from the back of the stove. Remove the front door to avoid
damage to the glass. Reminder: Loss of the door washer
will result in improper door alignment when reinstalling
the door.
Stove pipe stop
Traverse bar securing
smoke outlet cover to top
casting
Stove pipe top
Fig. 1
Upside down
Top casting
5
The adaptor should be inserted into the stove until the
bead on the adapter is flush with the top, back or side
casting. Now the adaptor is ready to accept single or
double walled stove pipe. See figure 4.
Each joint of chimney connector or stove pipe must be
secured with at least three sheet metal screws to ensure
that the sections do not separate.
Stove pipe - chimney connector
The chimney connector is a single walled pipe used
to connect the stove to the chimney. For use with the
Jøtul F3 the chimney connector must be 6” in diameter,
with a minimum thickness of 24 gauge black steel.
Aluminum and galvanized steel pipe is not acceptable for
use with the Jøtul F3. These materials cannot withstand
the extreme temperatures of a wood fire and can give off
toxic fumes when heated.
Each chimney connector or stove pipe section must be
installed to the stove flue collar and to each other with
the male (crimped) end toward the stove. See figure 5.
Fig. 5
Crimped end installed
toward the stove
USA/Canada
Using a claw hammer or a small sledge hammer strike the
center of the 6” “knock-out” disc from the outside of the
stove. The “knock-out” disc will break into four wedges
and may need to be tapped out. Touch up any remaining
sharp edges with a file or hand grinder.
Note: The enamel Jøtul F 3 ’s are rear vented from the
factory. It is not necessary to “knock-out” the rear casting
of the stove. However, if top exit is desired it is necessary to
install a smoke outlet cover on the rear outlet of the stove.
Reinstall the top casting and front door, remembering
the washer. The two rear heatshields must be reinstalled
on the stove. Remove the metal cover plates from the
heatshields and reinstall. Reminder: There is a small nut
used as a spacer between the two heatshields. See fig 2.
Fig. 2
Side exit venting
If venting through the side is desired it will be necessary
to remove the top casting. Using a 3mm allen wrench
remove the two set screws that secure to the top to the
side panels. Remove the front door to avoid damage to
the glass. Reminder: Loss of the door washer will result
in improper door alignment when reinstalling the door.
Using a claw hammer or a small sledge hammer strike the
center of the 6” “knock-out” disc from the inside of the
stove. The “knock-out” disc will break into four wedges
and may need to be tapped out. Touch up any remaining
sharp edges with a file or hand grinder. Reinstall the front
door, remembering the washer and the top casting.
Installing the stove pipe adapter
After the appropriate flue outlet in the stove has been
established the stove pipe adapter (included with every
stove) must be installed so that standard stove pipe can
be installed onto the stove.
Insert the end of the adapter with the four holes into the
stove. These holes allow the adaptor to be attached to the
stove’s internal collar, using the nuts and bolts provided
with the stove. See figure 3.
Spacers
Heatshield with listing
label should be installed
on the outside
Fig. 3
Direction into the
stove
Adaptor bead should
be flush with stove
Fig. 4
6
This prevents any amount of condensed or liquid creosote
from running down the outside of the pipe or the stove
top. All joints, including the flue collar connection must be
secured with three sheet metal screws to ensure that the
sections do not separate.
For the best performance the chimney connector should
be as short and direct as possible, with no more than two
90° elbows. The maximum horizontal run is 36” and a
recommended total length of stove pipe should not exceed
10 feet. Always slope horizontal runs upward 1/4” per foot
toward the chimney.
No part of the chimney connector may pass through an
attic or roof space, closet or other concealed space, or
through a floor or ceiling. All sections of the chimney
connectors must be accessible for cleaning. Where passage
through a wall or partition of combustible construction is
desired, the installation must conform with NFPA 211 or
CAN/CSA-B365, and is also addressed in this manual.
Do not connect this unit to a chimney flue servicing
another appliance.
Do not use the connector pipe as a chimney.
2.0 Chimney requirements
There are two types of chimneys suitable for the Jøtul F3:
1. A code- approved masonry chimney with a flue liner.
2. A prefabricated chimney complying with the
requirements for type HT (2100°F) chimneys per UL
103 or ULC S629.
The chimney size should not be less than the cross-
sectional area of the flue collar, and not more than three
times greater than the cross-sectional area of the flue
collar.
When selecting a chimney type and the location for the
ce of the chimney, as well as the proximity of surrounding
trees or buildings.
As a result, a short masonry chimney on the exterior of a
house will give the poorest performance. This is because it
can be very difficult to warm the chimney thereby creating
inadequate draft. In extremely cold northern areas it may
be necessary to reline the chimney or extend its height to
help establish draft.
Oppositely, a tall masonry chimney inside the house is
easier to keep warm and will perform the best.
The following guidelines give the necessary chimney
requirements based on the national code (ANSI-NFPA
211 for the us. And CSA CAN-B365 for Canada). However,
many local codes differ from the national code to take into
account climate, altitude, or other factors. It is important
that you check with your local building officials to find
out what codes apply in your area before installing your
new Jøtul F3.
USA/Canada
CHIMNEY INSPECTION: A Level II (camera) inspection
of an existing chimney system must be conducted by
a qualified technician as specified by NFPA 211 when
verification of the suitability of the chimney for new or
changed conditions of service is needed or when a Level
I inspection is not sufficient to determine serviceability
of the chimney.
Masonry chimneys
When installing the Jøtul F3 into a masonry chimney you
must conform to all of the following guidelines:
• The chimney flue size should not be less than the cross
sectional area of the stove flue collar.
• The cross-sectional area of the flue of a chimney with
no walls exposed to the outside below the roofline shall
not be more than three times the crosssectional area
of the stove flue collar.
• The cross-sectional area of the flue of a chimney with
one or more walls exposed to the outside below the
roofline shall not be more than two times the cross-
sectional area of the stove flue collar.
• Larger chimney flues should be relined with a listed or
code approved liner.
• The masonry chimney must have a fireclay liner or
equivalent, with a minimum thickness of 5/8” and must
be installed with refractory mortar. There must be at
least 1/2” air space between the flue liner and chimney
wall.
• The fireclay flue liner must have a nominal size of 8”
x 8”, and should not be larger than 8”x 12”. If a round
fireclay liner is to be used it must have a minimum
inside diameter of 6” and not larger than 8” in diameter.
If a chimney with larger dimensions is to be used, it
should be relined with an appropriate liner that is code
approved.
• The masonry wall of the chimney, if brick or modular
block, must be a minimum of 4” nominal thickness. A
mountain or rubble stone wall must be at least 12” thick.
• A newly-built chimney must conform to local codes and
in their absence must recognize national regulations.
• When using an existing chimney, it must be inspected
by a professional licensed chimney sweep, fire official,
or code officer, to ensure that the chimney is in proper
working order.
• No other appliance can be vented into the same flue.
• An airtight clean-out door should be located at the base
of the chimney.
7
Wall pass-throughs
When your installation unavoidably requires the chimney
connector to pass through a combustible wall to reach the
chimney, always consult your local building officials, and be
sure any materials to be used have been tested and listed
for wall pass-throughs.
In the U.S.
The national fire protection association’s publication,
NFPA 211, standard for chimneys, fireplaces, vents and solid
fuel burning appliances permits four methods for passing
through a combustible wall. Before proceeding with any
method be sure to consult with your local building officials
to discuss any local code requirements.
Common method
When passing through a combustible wall to a masonry
chimney this method requires the removal of all
combustible materials from at least 12” around the
chimney connectors proposed location. With a 6” round
liner the minimum area required would be 31” x 31” square.
The space is then filled with at least 12” of brick around a
fireclay liner. Remember, the liner must be ASTM C35 or
equivalent, with a minimum wall thickness of 5/8”.
It is important to remember to locate the pass-through
at least 18” from the ceiling for proper clearance to
combustibles.
It will be necessary to cut wall studs, install headers, and
construct a sill frame to maintain the proper dimensions
and to support the weight of the brick.
The bricks must be solid brick with a minimum of 3 1/2”
thick (4” nominal).
Refractory mortar must be used at the junction of the
chimney and the pass-through liner. The pass-through
liner must not penetrate the chimney liner beyond the
inner surface of the chimney liner. Use extreme care when
constructing the hole in the chimney liner, the tiles can
shatter easily. See figure 7.
Prefabricated chimneys
If a prefabricated metal chimney is to be used it must be
a chimney type that is tested and listed for use with solid
fuel burning appliances. High temperature (ht) chimney
standard UL103 for the U.S. And high temperature standard
ULC S-629 for Canada.
The manufacturer’s installation instructions must be
followed precisely. Always maintain the proper clearance
to combustibles as established by the pipe manufacturer.
This clearance is usually a minimum of 2”, although it may
vary by manufacturer or for certain chimney components.
Chimney height
Whether a masonry chimney or prefabricated metal
chimney is used it must be the required height above the
roof line.
The requirement is:
The chimney must be at least 3 feet higher than the highest
point where it passes through the roof and at least 2 feet
higher than the highest part of the roof or structure that
is within 10 feet of the chimney, measured horizontally.
See figure 6.
Fig. 6
At least 3 feet
At least 3 feet
10 feet
Chimneys shorter than 14 feet may not provide adequate
draft. This could result is smoke spilling into the room from
the stove when loading the stove, or when the door is open.
In addition, inadequate draft can cause back puffing, which
is a build up of gases inside the firebox.
Other times, chimney height can create excessive draft
which can cause high stove temperatures and short burn
times. Excessive drafts can be corrected by installing a
butterfly damper. If you suspect you have a draft problem,
consult your dealer.
USA/Canada
8
Fig. 7
Wood Stud 2”
Clearance to
Chimney
Header
12”
30.5 cm
Pass through
construction:
12” Brick from
thimble to
combustibles
Sill / Support
Flue Liner
Thimble: 5/8”
Fireclay Liner or
equivalent
In Canada
In Canada the standard has been established by the
canadian standard association. The installation must
conform to CAN/CSA-B365, installation code for solid fuel
burning appliances and equipment. Before proceeding be
sure to consult your local building inspector.
Common method
This method requires the removal of all combustible
materials from at least 18” (457mm) around the chimney
connector’s proposed location. With a 6” round liner the
minimum area required would be 43” x 43” square.
It is important to remember to locate the pass-through at
least 25” from the ceiling to maintain the proper clearance
to combustibles.
The space that is cleared of combustible materials must
then remain empty. Sheet metal panels can then be
used to cover the area. However, when using a panel on
both sides of the wall each cover must be installed on
noncombustible spacers at least 1” from the wall. If one
panel of sheet metal is to be used it may be installed flush
to the wall.
See section 5.3.1 and 5.3.2 of CAN/CSA - B365-m91.
Consult your local building inspector, authorized Jøtul
Dealer, NFPA 211 in the U.S. or CAN/CSA-B635 in Canada
for other approved wall pass-through methods.
3.0 Connecting to the
chimney
Masonry chimney
When installing a Jøtul F 3 into a masonry chimney through
a “thimble”(the opening through the chimney wall to the
flue), the thimble must be lined with ceramic tile or metal
and be securely cemented in place.
The chimney connector/stove pipe must slide completely
inside the thimble to the inner surface or the flue liner. It
may be necessary to make use of a thimble sleeve (a pipe
with a slightly smaller diameter than standard stove pipe).
This special pipe can be easily installed into a thimble. See
Figure 8.
Fig. 8
Connector pipe must
be flush with the
inside of the flue tile
Chimney
Connector
Pipe
Thimble
Flue Tile
Make sure the connector pipe or thimble sleeve does not
protrude into the flue liner, thereby restricting the area the
smoke has to flow through. This bottle-neck will have a
negative affect on the chimney system.
The chimney connector should be sealed at the thimble
with refractory cement and the stove pipe leading to the
stove should have a minimum of three screws.
Do not connect this stove to a chimney flue servicing
another appliance of any kind.
Hearth-mount into a masonry fireplace
The Jøtul F 3 may be installed into a masonry fireplace
provided the opening is a minimum of 28 1/2” high. The
short leg package reduces the stove’s height by 2 1/4”.
When installing the Jøtul F 3 into a masonry fireplace,
code requires that the fireplace damper plate be removed
or securely fixed in the open position. A connector pipe
must then extend from the stove’s flue exit through the
damper area of the fireplace and into the chimney tile
liner. See figure 9.
USA/Canada
9
Fig. 9
Tile liner
Connector extends to
first flue tile
Damper opening is sealed
with sheetmetal plate and
sealant
The inside area of the flue liner must not be less than
the area of the stove’s flue exit, and cannot be more than
three times greater than the cross sectional area of the
stove’s flue exit.
If the chimney liner is too large to accommodate the stove,
an approved relining system must be installed to resize
the flue.
A new sheet metal damper block-off plate must be
installed around the connector pipe at the damper frame
and sealed with the proper sealant (usually high-temp
silicone).
Fireplace installation must also observe the proper
clearances to surrounding trim and mantels (addressed
in clearance section of this manual). In addition, fireplace
installations must also adhere to the floor protection
guidelines specified in the following section.
Prefabricated chimneys
When installing the Jøtul F 3 to a prefabricated metal
chimney always follow the pipe manufacture’s instructions
and be sure to use the components that are required. This
usually includes some type of “smoke pipe adapter” that is
secured to the bottom section of the metal chimney and
allows the chimney pipe to be secured to it with three
sheet metal screws. See figures 10 and 11.
USA/Canada
Fig. 10
Listed Cap
Storm Collar
Flashing
Combustible
Ceiling Joists
Chimney
Connector
to
Stove
Ceiling
Support
Floor
Protector
Specified
Clearance
Listed
Chimney Attic
Insulation
Shield
Fig. 11
10
USA/Canada
4.0 Clearances to combustibles
Floor protection
Floor protection under the Jøtul F 3, must be one of the
following:
1. Any non combustible material with an insulative
R value of 1.1.
2. Any UL, ULC or WH hearth board or prefrabricated non-
combustible material.
The bottom heatshield (standard equipment) is required
in all installations.
Individual sections of floor protection must be mortared
together t,o prevent sparks from falling through to
combustible materials. Any carpeting must be removed
from under the floor protection.
In the U.S.and Canada
The Jøtul F 3 must be installed on a non-combustible
surface extending a minimum of 16” for U.S. (46 cm
for Canada) in front of the stove and 8” (20 cm) on the
remaining sides of the stove (measured from side and
back panels).
This will result in a minimum floor protection of 39 cm D x
39 cm W. for U.S.,and 104 cm D x 99 cm W for Canada.
See figure 12.
In a rear vent installation the floor protection must also
extend under the stove pipe a minimum of 2” (5 cm) beyond
either side of the pipe.
Fig. 12
2”
(5 cm)
39” U.S
(104 cm Can)
39” U.S.
(99 cm Can)
Hearth Protection
A: 8” (20 cm)
B: 16” for U.S. (46 cm for Canada)
B
AA
A
Clearances to walls and ceilings
The following clearances have been tested to UL and ULC
standards and are the minimum clearances specifically
established for the Jøtul F 3. (See next page)
The following charts and diagrams give the required
clearances you must maintain when installing the
Jøtul F 3 near combustible surfaces.
A combustible surface is anything that can burn (i.e. Sheet
rock, wall paper, wood, fabrics etc.). These surfaces are not
limited to those that are visible and also include materials
that are behind non-combustible materials.
If you are not sure of the combustible nature of a material,
consult your local fire officials.
Remember: “Fire resistant” materials are considered
combustible; they are difficult to ignite, but will burn.
Also “fire-rated” sheet rock is also considered combustible.
Contact your local building officials about restrictions and
installation requirements in your area.
Using shields to reduce clearances
Pipe shields: When using listed pipe shields to reduce
the connector clearance to combustibles, it must start 1”
above the lowest exposed point of the connect pipe and
extend vertically a minimum of 25” above the top surface
of the stove.
Double wall pipe: Listed double wall pipe is an acceptable
alternative to connector pipe heatshields.
Wall-mounted protection: When reducing clearances
through the use of wall mounted protection:
In the U.S. Refer to NFPA 211, standard for chimneys,
fireplaces, vents and solid fuel burning appliances, for
acceptable materials, proper sizing and construction
guidelines.
In Canada, refer to CAN/CSA-B365, installation code for
solid-fuel burning appliances and equipment, also for
acceptable materials, proper sizing and construction
guidelines.
Stove mounted rear heatshield is standard equipment
on all Jøtul F 3`s. No other stove mounted heat shield
may be used.
11
USA/Canada
Wall Shield for close clearance
Combustible wall
Wall Shield
Must be 30” wide and centred behind the stove.
Must be 1” off the wall and 1” off the floor.
With standard legs, the shield must be 32” high.
With optional short legs, the shield must be 30” high.
Combustible wall
Wall Shield
The wall shield must extend
a min. of 4” (102 mm) past
the side of the stove.
The wall shield must extend
a min. of 4” (102 mm) past
the ash lip of the stove.
Must be 1” off the wall and 1” off the floor.
With standard legs, the shield must be 40” high.
With optional short legs, the shield must be 38” high.
Both shields must extend and join in the corner.
Combustible wall
Wall shield
The wall shield must
extend a min. of 12” (305
mm) past the side of the
stove.
The wall shield must extend
a min. of 12” (305 mm) past
the ash lip of the stove.
Must be 1” off the wall and 1” off the floor.
With standard legs, the shield must be 40” high.
With optional short legs, the shield must be 38” high.
Both shields must extend and join in the corner.
12
A
BC
D
Jøtul F 3 Clearances
Stove Clearances Unprotected Surfaces Protected Surfaces
Top vent/vertical per NFPA 211 or CAN/CSA-B365-M
Side Rear Corner Side Rear Corner
Rear heatshield with 24” 25” 18” 10” 14” 10”
Single wall pipe 610mm 635mm 460mm 255mm 355mm 255mm
Rear heatshield with 18” 10” 14” 6” 6” 6”
Double wall pipe or shields 460mm 255mm 355mm 150mm 150mm 150mm
Stove Clearances Unprotected Surfaces Protected Surfaces
Rear Vent/Horizontal per NFPA 211 or CAN/CSA-B365-M
Side Rear Corner Side Rear Corner
Rear heatshield with 24” 25” 20” 10” 25” 18”
Single wall pipe 610mm 635mm 510mm 255mm 635mm 460mm
Rear heatshield with 18” 14” 17” 6” 6” 6”
Double wall pipe or shields 460mm 355mm 430mm 150mm 150mm 150mm
Connector Unprotected Surface Protected Surface
Clearances per NFPA 211 or CAN/CSA-B365-M
Singlewall pipe -vertical installations 18” (460mm) 6” (150mm)
Double wall pipe-vertical installations pipe mfgr. listing pipe mfgr. listing
Single wall pipe -horizontal installations 18” (460mm) 9” (230mm)
Double wall pipe-horizontal installations pipe mfgr. listing pipe mfgr. listing
Dimensions in Inches represent U.S. requirements.
Dimensions in Millimeters represent Canadian requirements.
Wall protection is discussed in further detail on page
10 of this manual.
A: Top to Mantel 34” 860 mm
B: Top to Top Trim 20” 510 mm
C: Side to Side trim 13” 330 mm
D: Side to Side Wall 24” 610 mm
USA/Canada
Maximum Mantel Depth: 11 1/2” 292 mm
Maximum Top and Side Trim Depth: 1 1/2” 38 mm
13
USA/Canada
Notice
Accessories for woodstoves for clearance reduction have
been developed by many manufacturers. If not following
the methods of the installation codes, be sure that any
accessory you choose has been tested by an independent
laboratory and carries the laboratory’s testing mark. Make
sure to follow all of the manufacturer’s instructions.
Always contact your local building inspector or fire
officials about restriction and requirements in your area.
Reminder, it is the local officials who have final authority
in the installations approval.
Alcove
The Jøtul F 3 is approved for installations in an unprotected
and protected alcove provided the following guidelines
are followed: Stoves must be positioned as shown in
figures 13 or 14.
Alcove floor protection must be: A UL/ULC or WHI listed
hearth board or a non combustible material with a
minimum r value of 1.1.
Minimum unprotected alcove:
Assumes-
Top exit, single wall pipe, and stove’s rear heatshield.
Minimum alcove width = 71” (1805mm)
Maximum alcove depth = 40” (1015mm)
Height above the top of the stove = 68” (1730mm)
Top vent/vertical - assumes the connector pipe is exiting
off the top of the stove and traveling vertically. If top
vented to any horizontal runs – the stove’s position is
dictated by the connector pipe clearances.
Minimum protected alcove:
Assumes-
Top exit, double wall pipe, and stove’s rear heatshield.
Minimum alcove width = 35” (890mm)
Maximum alcove depth= 24” (610mm)
Height above the top of the stove= 40” (1015mm)
In a protected alcove installation both side walls and rear
wall must be protected per NFPA 211 or CAN/CSA-B365. The
wall protection must be elevated 1” from the floor and at
least 1” off the combustible wall to allow for an air-flow.
Rear exit alcove installations:
Unprotected alcove: Assumes single wall pipe and stove’s
rear heatshield.
Minimum alcove width = 71” (1805 mm)
Maximum alcove depth = 40” (1015mm)
Alcove ceiling above top of stove = 68” (1730mm)
Protected alcove: Assumes double wall pipe and stove’s
rear heatshield.
Minimum alcove width = 35” (890mm)
Maximum alcove depth = 30” (760mm)
Alcove ceiling above top of stove = 40” (1015mm)
Max. depth
402 (1015 mm
71" (1805 mm)
25" (635 mm)
24"
(610mm)
24"
(610mm)
Fig. 13
Max. depth
24" (610 mm)
Min. 35" (890 mm)
10" (255 mm)
6"
(150)
6"
(150)
Fig. 14
14
5.0 Operation
Before building a fire in your new Jøtul F 3, please read the
following section carefully and completely.
Do not burn
First this stove is designed to burn natural wood only, wood
that has been air-dried for a period of 6 to 14 months will
provide the cleanest most efficient heat.
Do not burn:
*Coal *treated or painted wood
*Garbage *chemical chimney cleaners
*Cardboard *colored paper
*Solvents *any synthetic fuel or logs
The burning of any of these materials can result in the
release of toxic fumes. Never use gasoline, gasoline-type
lantern fuel, kerosene, charcoal lighter fluid, or similar
liquids to start or “freshen-up” the fire. Always keep such
liquids away from the heater at all times.
Important
Never build or allow the fire to rest directly on the glass.
The logs should always be spaced at least one inch from
the glass to allow for proper air flow within the stove.
Controls on the Jøtul F 3
There are two air controls on the Jøtul F 3.
The primary air control lever (A) is located on the front
of the stove in the top right corner. The primary air
lever controls the amount of air that enters the stove for
combustion.
The start-up air control lever (B) is located below the glass
in the center of the front door. This control is for “start -
up” air only and should not be used to freshen an existing
fire or during refueling. Never leave the stove unattended
while this control is open, overfiring could result, which
can damage the appliance. See figure 15.
When first starting a fire: The primary control lever should
be at the far right position, and the start-up air lever
should be in the far right position. This will allow for the
maximum amount of air to enter the stove and assist in
starting the fire quickly and most effectively.
Once the fire is established the start-up air lever should
be closed and the primary air lever should be adjusted
according to the amount of heat desired.
Remember: The more air entering the stove the hotter
the fire the shorter the burn time. Moving the primary air
lever to the left reduces the air-flow into the stove which
prolongs the fire at a lower heat output. See figure 15.
Breaking in your new stove
Your new Jøtul F 3 is constructed of cast iron and stove
furnace cement. This type of construction requires the
stove to be “broken-in” gradually so that heat expansion
does not occur too quickly and cause damage.
To monitor the stove’s temperature, Jøtul recommends the
use of a magnetic stove-top thermometer, placed directly
on the corner of the stove’s top plate.
Complete the following steps for the proper break-in
procedure for the Jøtul F 3:
1. Light a small fire, newspaper and kindling only,
only allow the stove to reach a maximum surface
temperature of 200°. Burn for approximately 1 hour.
2. Allow stove to cool to room temperature.
3. Light a second fire, allowing the stove to reach a
maximum temperature of 300° for 1 hour.
4. Cool the stove to room temperature.
5. Light a third fire and gradually allow the stove to reach
a surface temperature of 400°
6. Cool stove to room temperature. This completes the
“break-in” procedure.
Never allow the stove to exceed a 400° surface temperature
during any “break-in fire” with the exception of the last
“break-in” fire.
Note: It is normal for a new painted stove to emit an
odor and even smoke during its first several fires. This
is caused by the seasoning of the high temperature
paint and will diminish with each fire and will eventually
disappear. Opening a window or door to provide additional
ventilation will reduce the odor as this process takes its
course.
Fig. 15
A
B
USA/Canada
15
Never overfire the stove
If any part of the stove or chimney glows, you are
overfiring, and a house fire or serious damage to the stove
or chimney could result. Immediately close down the air
control if you notice this condition.
Starting and maintaining a fire
Burn only solid wood directly on the bottom grate of the
stove, do not elevate the fire in any way.
The ash pan door on the stove must always be securely
closed when the stove is in operation.
Burning the stove with the ashpan open will over-fire the
stove and cause interior damage.
With the primary air control lever and the start-up air
control lever in the full open position (far right), start with
several sheets of crumbled newspaper placed directly on
the grate. On top of the newspaper, place several pieces
of small dry kindling (approx. 1” in diameter) with two to
three larger logs (approx. 3” to 5” in diameter) on top.
Light the fire and close the door, slowly building the fire by
adding larger and larger logs. Close the start-up air control
lever after the fire is established and new fuel lights easily.
Be sure to follow the break-in procedure before creating
a fire that will damage the stove.
Once the stove has reached a surface temperature range
of between 400° and 600°, adjust the primary air control
lever as necessary to generate the heat output and burn
time desired.
Jøtul recommends the use of a magnetic stove top
thermometer to monitor the surface temperature of the
stove. The optimum surface temperature range for the
most efficient burn is between 400° and 600°.
See figure 16 below for the optimum locations of a stove-
top thermometer.
Adding fuel
When reloading the stove while it is still hot and a bed of
hot embers still exist, follow this reloading procedure:
• Always wear gloves when tending to the stove.
• Push the air control lever to the full open position (far
right).
• Wait a few seconds before opening the door.
• Use a stove tool or poker to distribute the hot embers
equally around the firebox.
• Load the fuel, usually with smaller logs first.
• Close the door, be sure to latch the door tightly.
• Wait 5 – 10 minutes before adjusting the primary air
to the desired heat output setting.
(If you have at least a 2” thick ember bed when
reloading, it may be possible to close the door and
immediately adjust the air control setting).
Creosote and Soot Formation and the Need
for Removal
When wood is burned slowly, it produces tar and other
organic vapors which combine with expelled moisture
to form creosote. These creosote vapors condense in the
relatively cool chimney flue of a slow burning fire. The
creosote that accumulates in the flue is highly flammable
and is the fuel of chimney fires. To prevent a chimney
fire, the creosote needs to be removed by sweeping the
chimney and flue connector. The frequency of sweeping
will depend on how you operate your stove, but it is
important to inspect the flue after every two weeks of
use. An accumulation of 1/4” or more on the sides of the
flue or connector is considered hazardous and should be
removed.
In the event that creosote in your chimney or flue connector
ignites, the resulting fire is often accompanied by a roaring
noise and a crackling sound as flakes of burned creosote
break loose. lf you suspect you are having a chimney fire,
immediately close the draft regulator and make sure the
stove door is closed. Call the fire department and get
everyone safely out of the house.
Trying to extinguish the fire in the stove will not help. In
fact it can make the matter worse by allowing oxygen
through the door, which then supports the fire in the
chimney. When the roaring and crackling has stopped, you
should resist the temptation to open the door and look at
the fire. The fire may have suffocated, but could rekindle
when you open the door. After a chimney fire, do not use
your stove until the chimney and the flue connector has
been cleaned and inspected to ensure that no damage
has been sustained.
Fig. 16
Stove top thermometer
USA/Canada
16
6.0 Maintenance
Ash removal: Of course, for your protection always wear
safety gloves when handling the ash pan.
Ash removal will be required periodically depending
on how frequently the stove is used. Conveniently, the
Jøtul F 3 is equipped with an ash pan assembly for easy ash
removal, without the need for opening the front doors.
The ash pan door is located under the front ashlip of
the stove. To open the ash door rotate the door knob
counterclockwise to unlatch the door and clockwise to
latch the door.
Remove the ash pan. When the stove is in operation
always close the ash pan door before leaving to dispose
of the ashes.
The ashes should be placed in a metal container equipped
with a tight sealing lid. The container should be placed on
a noncombustible floor or on the ground, well away from
all combustible materials, pending final disposal. If the
ashes are disposed of by burial in soil or otherwise locally
dispersed, they should be retained in the closed container
until all cinders have thoroughly cooled.
Glass care
Cleaning: On occasion it will be necessary to clean the
carbon deposits and fly ash off of the glass. If the carbon
and fly ash are allowed to remain on the glass for an
extended period of time it could eventually cause the
glass to become etched and cloudy. Any creosote, which
might deposit on the glass, will burn off during the next
hot fire.
The proper cleaning procedure is as follows:
1. Glass needs to be completely cool.
2. Only use a cleaner that is specifically designed for this
purpose. The use of abrasives will damage the glass
and ultimately leave the glass frosted.
3. Rinse and dry glass completely, before burning your
stove.
Important:
Replace glass only with a ceramic glass panel specifically
designed for the Jøtul F 3. Do not use substitutes.
Replacement glass panels can be ordered through your
Jøtul dealer.
Glass removal: Always operate the doors slowly and
cautiously to avoid cracking or breaking the glass. Never
use the door to push wood into the firebox. If the glass
becomes cracked or broken follow this procedure for
replacement:
Never operate the stove with a cracked or broken glass
panel.
1. Remove the door from the stove and place on a flat
surface.
2. Carefully remove all of the glass clips from the inside
of the door.
3. Gently remove all pieces of the glass panel and
gasketing.
4. Remove all remaining debris from the glass area using
a wire brush.
5. Apply a small bead of gasket/stove cement and the new
gasket. Do not overlap the ends of the gasket rope.
6. Center the new glass panel over the gasket and reinstall
the glass clips. See figure 17.
Important: The side of the glass treated with an
infrared coating (marked on the perimeter) should
always be facing outward. It is extremely important to
tighten the glass clips slowly and in a repeating pattern,
like tightening the lugs on an automobile wheel.
7. It may be necessary to retighten the glass clips after
the stove has be burned and the gasketing has been
seated.
Chimney System
The Jøtul F 3 is designed to burn cleanly and efficiently
when used according to the guidelines in this manual. In
order to maintain proper performance, you should inspect
the chimney and chimney connector at the beginning of
each heating season and then, twice a month during the
heating season. Clean the chimney whenever creosote
and fly ash accumulation exceeds 1/4 inch in any part of
the system.
Chimney brushes are available from your local Jøtul dealer
or hardware supply store. Your dealer can also refer you to
a reputable, professional chimney sweep who will have all
the equipment to ensure a complete and proper job. Failure
to keep the chimney system free of creosote and build up
could result in a serious chimney fire.
USA/Canada
17
7.0 General Maintenance
As with your car, regular maintenance will prolong the life
of your stove and ensure satisfactory performance.
The following procedures do not take long and are
generally inexpensive, but when done consistently,
increase the life of your appliance and in turn, increase
your years of enjoyment.
Enamel Care
• DO NOT ATTEMPT TO CLEAN HOT ENAMEL SURFACES.
Clean only cold enamel surfaces with a soft damp cloth
and polish with a clean dry cloth.
DO NOT USE SOAPY OR ABRASIVE SOLUTIONS. These
can cause stains. Coffee, tea, and fruit juices will also
cause stains.
• Avoid contact with metal objects. Trivets, kettles, or
pots, can damage the enamel.
• Empty stove of all soot and ashes. Only use a vacuum
for this job if the vacuum is specifically designed for
ashes.
• Inspect the stove seams. Use a utility light to inspect
the stove inside and out for cracks or leaks. Replace all
cracked parts and repair any cement leaks with furnace
cement.
Fig. 17
DoorGasket
Glass
Glass clips
Gaskets
Check door and window gaskets for tightness. To check
the seal of the front doors, close and latch the doors on a
dollar bill and slowly try to pull the dollar bill free. If it can
be easily removed then the seal is too loose. Check several
spots around the door, and repeat the procedure on the
ash pan door as well.
If gaskets need to be replaced, scrape out the old gasket
and cement and clean the area with a wire brush. Apply
a small bead of cement and push in the new gasket. After
closing and latching the doors wipe clean, any excessive
cement that has come from beneath the gasketing.
USA/Canada
Gasket list for the Jøtul F 3
Description Order # Size Length
Top plate gasket 100038 3/8” ld 6’
Ash housing gasket 128213 sheet gasket
Ash door gasket 200024 1/4” ld 3’
Glass gasket 200028 1/4” ld 3’6”
Door gasket 200024 11/32” ld 5’
Air manifold Gasket 200028 3/16” 16”
18
USA/Canada
8.0 Accessories
Many accessories have been manufactured for use with
the Jøtul F 3. Only use accessories that are specifically
designed for the Jøtul F 3.
Firescreen (part # 350168)
The Jøtul F 3 has been approved for use as an open fireplace,
with front door open. This feature is especially nice when
the ambience of a fire is desired. Some care should be taken
when operating the stove as a fireplace.
• Always have the firescreen in place, attached to the
stove front.
• Never over load the stove, for the best appearance burn
in the traditional three log configuration.
• Reminder, when burning the stove with the screen in
place, you are sacrificing efficiency for aesthetics, and
you will be consuming wood at a much faster rate.
Warning: Operate your Jøtul F 3 with the front door fully
open and the firescreen in place or fully closed. A partially
opened door may result in overfiring. Also, if the door is left
partly open, gas and flame may be drawn out of the stove
opening, creating risks from both fire and smoke.
Floor bracket kit (part # 750304)
The optional floor bracket kit can be used in the event
the stove needs to be secured to the floor. Complete
installation instructions and diagrams are supplied with
each floor bracket kit.
Stove-top thermometer (part # 5002)
Jøtul recommends the use of a magnetic stove-top
thermometer to monitor the surface temperature of the
stove. The optimum surface temperature range for the
most efficient, clean burn is between 400° and 600°.
19
Appendix A:
Alternate floor protection
All floor protection materials must be non-combustible ie. Metal,
brick, stone, mineral fiber boards). Any combustible material may
not be used.
The easiest means of determining if a proposed alternate floor
material meets requirements listed in this manual is to follow
this procedure.
R-value = thermal resistance
K-value = thermal conductivity
C-value = thermal conductance
1. Convert the specification to r-value;
a. If r-value is given, no conversion is needed.
b. If k-value is given with a required thickness (t) in inches:
R=1/k X T.
c. If c-value is given: R=1/C.
2. Determine the r-value of the proposed alternate floor
protector.
a. Use the formula in step 1 to convert values not expressed
as “R”.
b. For multiple layers, add r-values of each layer to
determine overall r-value.
3. If the overall R-value of the sustem is greater than the
R-value of the specified floor protector, the alternate is
acceptable.
Example:
The specified floor protector should be 3/4” thick material with a
k-factor of 0.84. The proposed alternate is 4” brick with a c-factor
of 1.25 over 1/8” mineral board witha k-factor of 0.29.
Step A. Use formula above to convert specifications to
R-value. R=1/k x t= 1/.84 x .75 = .893
Step B. Calculate r of proposed system.
4” brick of c-1.25, therefore
R brick = 1/c = 1/1.25 = 0.80
1/8” mineral board of K = 0.29 therefore
R mineral board = 1/.29 x 0.125 = 0.431
Total R = R brick + R mineral board= 0.8 + 0.431=1.231
Step C. Compare proposed system R = 1.231 to specified R of
0.893. Since R is greater than required, the system is
acceptable.
Definitions:
Thermal conductance =
C = btu = W
(Hr)(ft2)(f) (m2)(k)
Thermal conductivity =
K = btu = W = (btu)
(Hr)(ft2)(f) (m2)(k) (hr)(ft)(f)
Thermal resistance =
R = btu = (m2)(k) = (btu)(inch)
(Hr)(ft2)(f) W (hr)(ft2)(f)
For the Jøtul F 3 requires floor protection with a minimum
insulating R-value of 1.1.
Alcove installation require a minimum R-value of 1.1. (If a UL/ULC
or WHI listed hearth pad is not used.)
20
USA/Canada
21
USA/Canada
No Description, Dim./Spec.
1 Nut brass, M6x20 DIN 1587
2 Heat shield aluz. f/ivory en.
2 b Heat shield
3 Screw, M6x16 DIN 965
4 Nut , M6 DIN 934
5 Screw collar, M6x16 st.5.6 ubeh.
6 Cover smoke outlet rear
7 Traverse bar to cover smoke outlet rear
8 Top plate compl. w/ cover smoke outlet
9 Gasket, LD 375-2 9.5x1800
10 Cover smoke outlet side
11 Baffle plate
12 Air distributor USA
13 Cover smoke outlet top
14 Traverse/cover smoke outlet top
15 Back plate
16 Screw, M6x35 st.5.6 ubeh
17 Gasket, LD 360 M/L Ø8.7x150
18 Gasket, LD 360 M/L Ø8.7x560
19 Gasket, LD 250-2 M/L Ø6,4x540
20 Cast iron washer
21 Screw, M8x20 st.8.8
22 Side plate
23 Burn plate, back
24 Burn plate right
26 Air deflektor
27 Gasket, LD 187-1 M/L 4.8x410
28 Sliding vent
29 Front plate
30 Washer, Ø12x6x0.5
31 Log retainer.
32 Screw, M6x8 poz
33 Glass clip w\ gasket
34 Gasket, LD 360 Ø8.7x1480
35 Door compl. w/o glass
37 Hinge pin, Ø0,6x33
38 Ignition vent
39 Washer, D nr. 531241
40 Cover/ign. vent
41 Screw/collar, M6x12 st. 8.8 ubeh.
42 Handle compl., nickel-plated
43 Locking bar
44 Gasket, LD 187 m\l Ø4,8x1800
45 Glass , 358 x 233 mm
46 Spark screen
48 Spring
49 Knob, plastic, 0,30mm M6
50 Screw collar, M6x16 st. 5.6
51 Ash lip
52 Leg
53 Skrew M6x20 ST 8,8 ubeh.
54 Washer, Ø18x0,6, 4x1
55 Bottom plate,
57 Inner bottom plate
58 Screw sink head, M6x25 sortkrom.poz. (black-poz.)
59 Burn plate left
60 Insulation, Firemaster blanket (after X-607)
61 Screw , M8x25 st.8.8
62 Cover/sec. air inlet,
63 Screw sinkhead, M6x40 poz DIN 965
64 Gasket-flat
65 Ash house w\ heat shield and hinge (after 1998)
66 Hinge, ash house (before 1998)
69 Screw sh Pozid, M6x10 DIN 965 (before 1998)
70 Ash box, 1mm steel plate
71 Hinge pin, Ø6x100
72 Locking screw, M6x10 DIN915
73 Handle for ashdoor
74 Handle stub
75 Spring
76 Door ashroom complete,
77 Gasket, LD 250-2 Ø6.4x730
78 Door latch
79 Gasket, LD 250 m\l Ø6,4x600
81 Hexagon nut, M8 DIN 934
82 Locking pin, M6x20 DIN 914
83 Fixing bracket
84 Air blocker (for USA)
85 Heat shield rear (for Germany)
86 Heat shield under (for Germany)
87 Extention nut for heat shield, rear (for Germany)
M6x18mm
88 Distance sleeve for heatshield, under (for Germany)
Ø10xØ6,2x15mm
89 Self closing mechanism (for Germany)
90 Nut , M10 DIN 934
91 Door latch, 3mm stainless steel
92 Spring Ø10 inside, 2mm stainless steel
93 latch bolt ash door, Steel
94 Wooden knob, Hard wood
95 Skrew, M6x60 DIN 84
1-1331-P22
Only use replacements parts provided through your
authorized Jøtul dealer.
Part list for Jøtul F 3
22
9.0 Jøtul N. A. wood-
burning product limited
warranty
Effective February 1, 2010
This warranty policy applies to wood-burning products identified
by Jøtul and Scan trade names, as set forth below.
A. Cast Iron, Enamel, and Steel Components:
Jøtul North America Inc. (JØTUL) warrants, to the original retail
purchaser, that those components of the Jøtul or Scan Stove
or Fireplace specified above will be free of defects in material
and workmanship for a period of five (5) years from the date of
purchase. This warranty is subject to the terms, exclusions and
limitations set forth in the following text.
B. Electrical Components (blowers,
thermostatic switches):
JØTUL warrants, to the original retail purchaser, that those
components of the Jøtul or Scan Stove or Fireplace specified
above will be free of defects in material and workmanship for a
period of one (1) year from the date of purchase. This warranty
is subject to the terms, exclusions, and limitations set forth in
the following text
JØTUL will repair or replace (including parts & labor), at its
option, any of the above components determined by JØTUL to be
covered by this warranty. You must, at your own expense, arrange
to deliver or ship the component to an authorized Jøtul or Scan
dealer and arrange for pickup or delivery of the component after
repairs have been made. If, upon inspection, JØTUL determines
that the component is covered by this warranty, the repair or
replacement will be made as set forth above. This warranty is
not transferable and is extended only to, and is solely for the
benefit of, the original retail purchaser of the Jøtul or Scan Stove
or Fireplace. This paragraph sets forth the sole remedy available
under this warranty in the event of any defect in the Jøtul or
Scan Stove or Fireplace.
The warranty period for any replaced component will be the
remaining unexpired portion of the warranty period for the
original component.
Please retain your dated sales receipt in your records as proof
of purchase.
Exclusions and limitations
Notice: This warranty is void if installation or service is performed
by someone other than an authorized installer or service agency,
or if installation is not in conformance with the installation and
operating instructions contained in this owner’s manual or local
and/or national fire and building regulations. A listing of local
authorized installers, service agencies and gas suppliers can be
obtained from the National Fireplace Institute at http://www.
nficertified.org/.
This warranty does not cover the following:
1. Repair or replacement of parts that are subject to normal
wear and tear during the warranty period or to parts that may
require replacement in connection with normal maintenance.
These parts include paint, gaskets, burn plates, baffles,
air manifolds, firebricks, fire grates, or glass (glass is only
warranted against thermal breakage).
2. Damage due to incorrect installations not in conformance
with the installation instructions contained in this owner’s
manual or local and/or national fire and building regulations.
3. Damage, including damage to enamel surfaces, caused by
improper operation, over-firing, and/or misuse. Improper
operation, such as burning the stove with the ash door open,
can damage the stove. Over-firing occurs when any part of
the stove glows red. Over-firing can also be identified by
warped plates, rust-colored cast iron, paint pigment that has
turned dusty white, or bubbling, cracking and discoloration of
the enamel finish. Misuse includes, without limitation, use
that is not in conformance with the operating instructions
contained in this owner’s manual.
4. Damage due to service performed by an installer or service
agency, unless otherwise agreed to in writing by JØTUL.
5. Damage caused by unauthorized modification, use or repair.
6. Costs incurred by travel time and/or loss of service.
7. Labor or other costs associated with the repair of components
beyond the warranty period.
8. Damage incurred while the Jøtul or Scan Stove or Fireplace
is in transit.
IN NO EVENT SHALL JØTUL, ITS PARENT COMPANY, SHAREHOLDERS,
AFFILIATES, OFFICERS, EMPLOYEES, AGENTS OR REPRESENTATIVES
BE LIABLE OR RESPONSIBLE TO YOU FOR ANY SPECIAL, INDIRECT,
INCIDENTAL, CONSEQUENTIAL, PUNITIVE OR OTHER SIMILAR
DAMAGES, INCLUDING, BUT NOT LIMITED TO, LOST PROFITS,
LOST SALES, INJURY TO PERSON OR PROPERTY, OR DAMAGES TO
A STRUCTURE OR ITS CONTENTS, ARISING UNDER ANY THEORY
OF LAW WHATSOEVER. ALL IMPLIED WARRANTIES, INCLUDING
THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS
FOR A PARTICULAR PURPOSE, OR OTHERWISE, ARE LIMITED
IN DURATION TO THE LENGTH OF THIS WRITTEN WARRANTY.
EXCEPT AS EXPRESSLY SET FORTH HEREIN, JØTUL MAKES NO
ORAL, WRITTEN OR OTHER WARRANTY WITH RESPECT TO JØTUL
OR SCAN STOVES OR FIREPLACES.
Some states do not allow the exclusion or limitation of incidental
or consequential damages, or limitations on the length of implied
warranties. Therefore, the above exclusions or limitations may
not apply to you. This warranty gives you specific legal rights,
and you may have other rights, which vary from state to state.
JØTUL reserves the right to discontinue, modify or change the
materials used to produce the Jøtul or Scan Stove or Fireplace.
JØTUL shall have the right to replace any defective component
with substitute components determined by JØTUL to be of
substantially equal quality and price.
USA/Canada
23
The dollar value of JØTUL’s liability for breach of this warranty
shall be limited exclusively to the cost of furnishing a replacement
component. JØTUL shall not in any event be liable for the cost
of labor expended by others in connection with any defective
component. Any costs or expenses beyond those expressly
assumed by JØTUL under the terms of this warranty shall be
the sole responsibility of the owner(s) of the Jøtul or Scan Stove
or Fireplace.
No dealer, distributor, or other person is authorized to modify,
augment, or extend this limited warranty on behalf of JØTUL.
NO MODIFICATION OR CHANGE TO THIS WARRANTY WILL
BE EFFECTIVE UNLESS IT IS MADE IN A WRITTEN DOCUMENT
MANUALLY SIGNED BY AN AUTHORIZED OFFICER OF JØTUL.
An authorized installer may have been provided with certain
information related particularly to the Jøtul or Scan Stove or
Fireplace; however, no authorized installer or other person who
may service the appliance is an agent of JØTUL. No inference
should be made that JØTUL has tested, certified, or otherwise
pronounced any person as qualified to install or service the
appliance. JØTUL shall not be liable or otherwise responsible for
any error or omission by a person installing or servicing a Jøtul
or Scan Stove or Fireplace.
If you believe your Jøtul or Scan Stove or Fireplace is defective,
you should contact your nearest authorized Jøtul or Scan dealer,
who will process a warranty claim. IN ORDER TO QUALIFY FOR
WARRANTY COVERAGE, JØTUL MUST RECEIVE NOTICE OF A
POSSIBLE DEFECT WITHIN SIXTY (60) DAYS OF THE DATE THE
DEFECT IS FIRST DISCOVERED, OR REASONABLY COULD HAVE
BEEN DISCOVERED.
This warranty is given by Jøtul North America, Inc.,
55 Hutcherson Drive, Gorham, Maine 04038 USA
USA/Canada
24
25
26
27
Jøtul pursue a policy of constant product development. Products supplied may therefore
differ in specification, colour and type of accessories from those illustrated and described in
the brochure.
Jøtul vise sans cesse à améliorer ses produits. C’est pourquoi, il se réserve le droit de modifier
les specifications, couleurs et équipements sans avis prélable.
Quality
Jøtul AS has a quality system that conforms to NS-EN ISO 9001 for product development,
manufacturing, and distribution of stoves and fireplaces. This policy gives our customers
quality and safety piece of mind as a result of Jøtul’s vast experience dating back to when the
company first started in 1853.
We appreciate your trust in welcoming our product into your home and invite your comment
and appraisal of our efforts to provide you with the finest in home hearth products.
Qualité
Le système de contrôle de la qualité de Jøtul AS est conforme à la norme NS-EN ISO 9001 relative
à la conception, à la fabrication et à la distribution de poêles, foyers et inserts. Cette politique
nous permet d’offrir à nos clients une qualité et une sécurité reposant sur la vaste expérience
accumulée par Jøtul depuis sa création en 1853.
Ca
t
.
n
o
.
1
0
0
2
4
3
7
2
(
1
2
8
7
4
4
)
Dr
a
w
.
n
o
.
4
-
3
4
3
1
-
P
1
1
Jø
t
u
l
A
S
,
J
u
n
e
,
2
0
1
2
Jøtul North America Inc
55 Hutcherson Drive
Gorham, Maine 04038, USA
Jøtul AS,
P.o. box 1411
N-1602 Fredrikstad,
Norway
www.jotul.com