Loading...
HomeMy WebLinkAboutB12-0092 plans corrections required RECEI V V ED 04/06/2012 PRJ12-0135 NA B12-0092 Vail Village Filing 7 1 ABC Manor Vail 254 Unit Renovation (2/27/12) Electrical Load Calculation (Includes Renovation) Square Footage: Total Unit…………….1512’ _____________________________________________________ General Load 1. General Lighting at 3VA per ft. 4536_ 2. Small Appliance 4500_ 3. Laundry 1500_ 4. Range 9600_ 5. Dishwasher 1200_ 6. Dryer 5500_ 7. Refrigerator 1200_ 8. Electric Heat Mats 1050 9. Total 29086 Application of Demand 10. First 10kVA of general load at 100% 100 00 11. Remainder of general load at 40% 7634 12. Total 17634 Total Connected Load 17634 Amp/Volts Total Connected Amps 85 Amps Existing Service Size 100 Amps 2668 REF.D/W REF.UP R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R 4 4 4 3 3 6'-1" x 19'-11"9'-6 1/2"13'-3 3/8"4'-0"29'-4"5'-3"16'-0"14'-5 5/8"17'-11 1/8"4'-8 1/2"6'-0 1/2"8'-8 1/2"18'-0 1/4"32'-6 5/8"55'-5 5/8"Manor Vail #254 Pratt Residence 1) 1/19/2012 2) Rev-1/25 3) Rev-1/26 4) Rev - 2/22 A1 Bench New Owners Closet Owners Closet New Washer & Dryer Bench Bar 4'-6"10'-8"15'-3"12'-5"12'-6"13'-10"Owner's Cabinet Cubbies & Hooks DECK NOTES 1) Relocate 2 Sprinkler Heads 2) Verify Carbon Monoxide Detector Installed 3) Asbestos Test (see results)4) Verify Dryer Venting 5) Electrical Load Calculations 6) Tent to Code Lighting Cans New Gas Fireplace Insert Section SX1 Scale- 1/4" = 1'