Loading...
HomeMy WebLinkAboutA12-0079 Stamped approved plansFRIDGE DN RESIDENCE MAILBOXESFRIDGE DN RESIDENCE MAILBOXES E E E E E E E E E E E E E E E E E E E TVE E +44 E +44E+4 4 E N NN J +60 N +60 TV +60 N N NN N TE+4 4 T E +4 4 N+44 N +44 N +7 2 N +7 2 N N +44 N DN RESIDENCE MAILBOXES DN RESIDENCE MAILBOXES E E E E E E E E EEE EE E E E E E E E E EE EE E E E E E E E E SD SD SD SD RR RR R R R R RR RR R R RR R R R R FA 220V J TV +60 J +60 Entry Other Tenant 101 BREAK RM. 102 OFFICE 104 FILE RM. 100 RECEPTION 103 STORAGE 105 COATS/IT 102 101 104 100B 103 1A2-2 5 6 1A2-2 6.1 ALIGN 6' - 0" 2' - 8 " 8' - 7" 3' - 0 " 12 ' - 1 " 21' - 9"3' - 5" 100A 6" 6" 6" 6.2 A5 A5 A5 A5 A5 A5 A5 9 1A2-2 Entry Other Tenant 101 BREAK RM. 102 OFFICE 104 FILE RM. 100 RECEPTION 103 STORAGE 105 COATS/IT 16.2 16.2 8' - 5 " 6' - 11" 5.1 5.1 5.1 5.1 5.1 +8'-0" +8'-0" +9'-0" +9'-0" +8'-0" 7 1A2-2 7 1A2-2 7 1A2-2 102 104 100 101 103 105 REFLECTED CEILING LEGEND NOTE: COMPONENTS AND FIXTURES SHOWN ARE DESIGNATED 'N' (NEW), 'E' (EXISTING TO REMAIN), 'R' (RELOCATED), 'D' OR DASHED (TO-BE-REMOVED). REFER TO ENGINEERING DRAWINGS FOR ADDITIONAL INFORMATION, SWITCHING, ALL HVAC, FIRE DETECTION/ALARM, AND SPRINKLER LAYOUT. E GYPSUM BOARD CEILING/SOFFIT AT HEIGHT NOTED +8'-6"CEILING HEIGHT INDICATION ABOVE FINISHED FLOOR LEVEL EXISTING RECESSED CANNED LIGHT TO REMAIN R RELOCATED RECESSED CANNED LIGHT NEW PENDANT MOUNTED LIGHT - LBL WILT BOWL CEILING JC389AM EXISTING SPRINKLER HEAD. RELOCATE AS REQUIRED BASED ON NEW PARTITION LAYOUT. SD EXISTING SMOKE DETECTOR. RELOCATE AS REQUIRED BASED ON NEW PARTITION LAYOUT. ACCESS PANEL. REFER TO KEYNOTES REFLECTED CEILING GENERAL NOTES 1. HATCHED AREA NOT IN CONTRACT - NO NEW WORK THIS AREA. 2. REFER TO ENGINEERING DRAWINGS FOR ADDITIONAL REQUIREMENTS 3. EXISTING HARD LID CEILINGTO REMAIN. PATCH AND REPAIR AS REQUIRED BY ACCESS PANEL RELOCATION. REFER TO KEYNOTES. 4. PROVIDE NEW AREA OF DRYWALL CEILING AT ELEVATION TO MATCH EXISTING AT OFFICE 102. REFER TO KEYNOTES. 5. REFER TO ENGINEERING DRAWINGS FOR ALL SWITCHING. ARCHITECTURAL GENERAL NOTES 1. REFER TO GENERAL NOTES AND SPECIFICATIONS. 2. HATCHED AREA NOT IN CONTRACT. IT SHALL BE ASSUMED THAT THE DEMISING WALL BETWEEN OUR SCOPE OF WORK AND EXISTING TENANT IS ALREADY IN PLACE. GC IS RESPONSIBLE FOR 1-SIDE OF ROCK ONLY. 3. PATCH AND REPAIR EXISTING PARTITIONS WHERE DEMOLITION HAS OCCURED, INCLUDING THE REMOVAL OF WALL OUTLETS, BLANK COVER PLATES, AND THERMOSTATS. REPAIR DRYWALL AND PREPARE FOR SPECIFIED FINISH. 4. WHERE NEW ELEMENTS ARE ADJACENT TO EXISTING ELEMENTS, ALIGN FINISHED SURFACES, UNLESS NOTED OTHERWISE. 5. WHERE NEW PARTITION IS SHOWN PERPENDICULAR TO PERIMETER MULLION, CENTER PARTITION ON MULLION USING BUILDING STANDARD CONNECTION DETAIL. FOR RATED CONDTITIONS. REFER TO DETAIL SHEET. 6. NOTIFY ARCHITECT OF ANY AREAS WHERE DIMENSIONAL REQUIREMENTS CANNOT BE MET OR EXCEED DIMENSIONS SHOWN FOR CLARIFICATION. 7. ALL NEW DOOR LOCATIONS ARE TO HAVE 18" CLEAR ON PULL SIDE AND 12" CLEAR ON PUSH SIDE TO MEET ANSI REQUIREMENTS. NOTIFY ARCHITECT OF ANY DOOR LOCATIONS NOT MEETING THIS REQUIREMENT PRIOR TO ROUGH-IN. 8. ALL NEW DOOR LOCATIONS ARE TO HAVE 6" CLEAR (TYP.) ON HINGE SIDE, UNLESS NOTED OTHERWISE. 9. DOOR PREP FOR ACCESS CONTROL DEVCIES IS BY GENERAL CONTRACTOR. ELECTRIC HARDWARE AND INSTALLATION OF HARDWARE (AND LOW VOLTAGE WIRING) IS BY TENANTS SECURITY VENDOR. COORDINATE WITH TENANT'S SECURITY VENDOR. 10. COORDINATE HARDWARE FINISH WITH TENANT ACCESS CONTROL VENDOR. 11. PROTECT FLOOR COVERING TO REMAIN FROM DAMAGE DURING DEMOLITION AND NEW CONSTRUCTION. 12. REFER TO DOOR SCHEDULE FOR NEW DOORS THROUGHOUT. DOORS SHALL BE 2-PANEL PROFILE BY TRUSTILE WITH CUST WOOD FRAME. STAIN TO MATCH ARCH SAMPLE. 13. STUD SIZE AT ALL NEW PARTITIONS SHALL MATCH EXISTING/ADJACENT. POWER / COMMUNICATION GENERAL NOTES 1. REFER TO GENERAL NOTES AND SPECIFICATIONS. 2. HATCHED AREA NOT IN CONTRACT. 3. REFER TO ENGINEERING DRAWINGS FOR ADDITIONAL REQUIREMENTS. 4. ALL ELECTRICAL DEVICES SHOWN ARE NEW (N) UNLESS NOTED AS 'E' (EXISTING TO REMAIN) OR SHOWN DASHED (TO BE REMOVED). 5. ALL NEW POWER & COMMUNICATIONS DEVICES TO BE INSTALLED AT HEIGHT AND ORIENTATION TO MATCH EXISTING DEVICES, UNLESS NOTED OTHERWISE. 6. ALL ACCESS CONTROL DEVICES TO BE UNDER SEPARATE PERMIT. COORDINATE WITH TENANT'S SECURITY VENDOR. 7. REPAIR ALL WALL SURFACES WHERE WALL-MOUNTED DEVICES ARE REMOVED DURING DEMOLITION. 8. REVIEW ALL THERMOSTAT LOCATIONS WITH ARCHITECT PRIOR TO INSTALLATION. REFER TO ENGINEERING DRAWINGS. 9. REFER TO ENGINEERING DRAWINGS FOR POWER TO PLENUM-MOUNTED EQUIPMENT. 12. REFER TO ENGINEERING DRAWINGS AND KEYNOTES FOR EQUIPMENT SPECIFICATIONS/INFORMATION. 10. ALL NEW PHONE AND COMMUNICATIONS CABLING COVERPLATES AND TERMINATIONS TO BE BY CABLING SUBCONTRACTOR 11. REMOVE ALL DATA AND COMMUNICATION CABLING EXCEPT DATA AND COMMUNICATION CABLING WHICH MAY PASS THROUGH THIS FLOOR AND SERVICE OTHER TENANTS. OBTAIN FURTHER CLARIFICATION FROM LANDLORD IF REQUIRED. LEAVE CABLING OF SUFFICIENT LENGTH AT ANY EXISTING LOCATIONS SHOWN TO REMAIN TO BE USED AS PULL CABLE BY CABLING VENDOR.. 12. FIELD COORDINATE ANY EXISTING DEVICES TO REMAIN AND ANY DEVICES TO BE REMOVED NOT SHOWN HERE. WALL MOUNTED DUPLEX OUTLET WALL MOUNTED FOURPLEX OUTLET WALL MOUNTED DEDICATED DUPLEX OUTLET WALL MOUNTED 220V DUPLEX OUTLET CEILING MOUNTED DUPLEX OUTLET CEILING MOUNTED FOURPLEX OUTLET FLUSH FLOOR MOUNTED DUPLEX OUTLET FLUSH FLOOR MOUNTED FOURPLEX OUTLET FLUSH FLOOR MOUNTED DUPLEX OUTLET WALL MOUNTED VOICE/DATA ROUGH-IN BOX CEILING MOUNTED VOICE/DATA RECEPTACLE FLUSH FLOOR MOUNTED VOICE/DATA RECEPTACLE WALL MOUNTED JUNCTION BOX FLUSH FLOOR MOUNTED JUNCTION BOX WALL MOUNTED COAXIAL CONNECTION POWER & COMMUNICATIONS LEGEND DEVICES ARE NOTED 'N' FOR NEW, 'E' FOR EXISTING, 'D' OR SHOWN DASHED TO BE REMOVED 123456789101112131415 A B C D E F G H I J K Proj. No.: Date: Drawn By: Sheet No.: Scale: P.M.: Checked: File Name: ALL DIMENSIONS AND CONDITIONS MUST BE CHECKED AND VERIFIED ON SITE BY THE CONTRACTOR AND SUBCONTRACTORS. THE PROJECT MANAGER SHALL BE NOTIFIED IN WRITING OF ANY DISCREPANCIES PRIOR TO PROCEEDING WITH THE WORK. COPYRIGHT ACQUILANO LESLIE INC. ALL RIGHTS RESERVED PROJECT NAME ACQUILANOLESLIEINC. architecturei nteriordesignarchitectureinteriordesign 1600STOUTSTREET SUITE200 DENVER,COLORADO80202 TEL:303.893.5355 FAX:303.893.6840 DESIGN@ACQ UILANO.COM __________ WWW.ACQUILANO.COM As indicated 9/18/2012 3:43:56 PM 12 Vail Road Vail, Colorado 1A2-1 ARCH/POWER/RCP 12-23A 09/10/12 AuthorChecker Approver Bill Esrey Office DescriptionNo.Date 3/16" = 1'-0"1 1A2-1 (ARCH) DOOR SCHEDULE DOOR #WIDTHHEIGHT HARDWARE GROUP Fire RatingDOOR FINISHFRAME FINISHFRAME TYPEDoor Notes 100B3' - 0"7' - 10"1.6.1-TRUSTILE 2-PANEL DOOR - TS2170 STARKE WOOD CASING #2097 WOOD 1023' - 0"7' - 10"1.2.1-TRUSTILE 2-PANEL DOOR - TS2170 STARKE WOOD CASING #2097 WOOD 1012' - 6"7' - 10"1.1.1-TRUSTILE 2-PANEL DOOR - TS2170 STARKE WOOD CASING #2097 WOOD 1032' - 0"7' - 10"1.1.1-TRUSTILE 2-PANEL DOOR - TS2170 STARKE WOOD CASING #2097 WOOD 1043' - 0"7' - 10"1.1.1-TRUSTILE 2-PANEL DOOR - TS2170 STARKE WOOD CASING #2097 WOOD 100A3' - 0"7' - 10"1.9.1-EXISTING TO REMAIN EXISTING TO REMAIN FRAMELESS 3/16" = 1'-0"2 1A3-1 (POWER) 3/16" = 1'-0"3 1A4-1 (RCP) KEYNOTE 5.1RELOCATED ACCESS PANEL. REFER TO GENERAL NOTES. 6.1PROVIDE BLOCKING IN PARTITIONS FOR WALL MOUNTED TELEVISION. COORDINATE HEIGHT WITH ARCH. 6.2PROVIDE AND INSTALL NEW WOOD VALANCE TO CONCEAL WINDOW TREATMENTS BY OTHERS. REFER TO RCP & DETAILS. 16.2RELOCATE ALL POWER AND DATA DEVICES LOCATED IN EXISTING WALL BASE, TO DIRECTLY ABOVE NEW WALL BASE AND BELOW WINDOW SILL. KEYNOTE 5.1RELOCATED ACCESS PANEL. REFER TO GENERAL NOTES. 6.1PROVIDE BLOCKING IN PARTITIONS FOR WALL MOUNTED TELEVISION. COORDINATE HEIGHT WITH ARCH. 6.2PROVIDE AND INSTALL NEW WOOD VALANCE TO CONCEAL WINDOW TREATMENTS BY OTHERS. REFER TO RCP & DETAILS. 16.2RELOCATE ALL POWER AND DATA DEVICES LOCATED IN EXISTING WALL BASE, TO DIRECTLY ABOVE NEW WALL BASE AND BELOW WINDOW SILL. KEYNOTE 5.1RELOCATED ACCESS PANEL. REFER TO GENERAL NOTES. 6.1PROVIDE BLOCKING IN PARTITIONS FOR WALL MOUNTED TELEVISION. COORDINATE HEIGHT WITH ARCH. 6.2PROVIDE AND INSTALL NEW WOOD VALANCE TO CONCEAL WINDOW TREATMENTS BY OTHERS. REFER TO RCP & DETAILS. 16.2RELOCATE ALL POWER AND DATA DEVICES LOCATED IN EXISTING WALL BASE, TO DIRECTLY ABOVE NEW WALL BASE AND BELOW WINDOW SILL. HARDWARE SCHEDULE GROUP#RATINGHARDWARE COMPONENTSSECURITY COMPONENTSNOTES ENTRY 1.6.11-1 ENTRY LOCKSET; 2 PAIR HINGES; 1 CLOSER; WALL or FLOOR STOP; 1 SET SILENCERS GLASS 1.9.11-EXISTING TO REMAIN.EXISTING TO REMAIN.EXISTING TO REMAIN OFFICE 1.2.11-1 OFFICE LOCKSET; 2 PAIR HINGES; 1 WALL or FLOOR STOP; 1 SET SILENCERS PASSAGE 1.1.13-1 PASSAGE SET; 2 PAIR HINGES; 1 WALL or FLOOR STOP; 1 SET SILENCERS By David Rhoades at 9:51 am, Nov 12, 2012