HomeMy WebLinkAboutA12-0079 Stamped approved plansFRIDGE
DN
RESIDENCE
MAILBOXESFRIDGE
DN
RESIDENCE
MAILBOXES
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
TVE
E
+44
E
+44E+4
4
E
N
NN
J
+60 N
+60
TV
+60
N
N
NN
N
TE+4
4
T E +4
4
N+44
N
+44
N +7
2
N +7
2
N
N
+44
N
DN
RESIDENCE
MAILBOXES
DN
RESIDENCE
MAILBOXES
E
E
E
E
E
E
E
E
EEE
EE
E
E
E
E
E
E
E E
EE
EE
E
E
E
E
E
E
E
E
SD
SD
SD
SD
RR
RR
R
R
R
R
RR
RR
R
R
RR
R
R
R
R
FA
220V
J
TV
+60
J
+60
Entry
Other
Tenant
101
BREAK RM.
102
OFFICE
104
FILE RM.
100
RECEPTION
103
STORAGE
105
COATS/IT
102
101
104
100B
103
1A2-2
5
6
1A2-2
6.1
ALIGN
6' - 0"
2'
-
8
"
8' - 7"
3'
-
0
"
12
'
-
1
"
21' - 9"3' - 5"
100A
6"
6"
6"
6.2
A5
A5
A5
A5
A5
A5 A5
9
1A2-2
Entry
Other
Tenant
101
BREAK RM.
102
OFFICE
104
FILE RM.
100
RECEPTION
103
STORAGE
105
COATS/IT
16.2
16.2
8'
-
5
"
6' - 11"
5.1
5.1
5.1
5.1 5.1
+8'-0"
+8'-0"
+9'-0"
+9'-0"
+8'-0"
7
1A2-2
7
1A2-2
7
1A2-2
102 104
100
101
103
105
REFLECTED CEILING LEGEND
NOTE: COMPONENTS AND FIXTURES SHOWN ARE DESIGNATED 'N' (NEW),
'E' (EXISTING TO REMAIN), 'R' (RELOCATED), 'D' OR DASHED (TO-BE-REMOVED).
REFER TO ENGINEERING DRAWINGS FOR ADDITIONAL INFORMATION,
SWITCHING, ALL HVAC, FIRE DETECTION/ALARM, AND SPRINKLER LAYOUT.
E
GYPSUM BOARD CEILING/SOFFIT AT HEIGHT NOTED
+8'-6"CEILING HEIGHT INDICATION ABOVE FINISHED FLOOR LEVEL
EXISTING RECESSED CANNED LIGHT TO REMAIN
R RELOCATED RECESSED CANNED LIGHT
NEW PENDANT MOUNTED LIGHT - LBL WILT BOWL CEILING JC389AM
EXISTING SPRINKLER HEAD. RELOCATE AS REQUIRED BASED ON NEW PARTITION LAYOUT.
SD EXISTING SMOKE DETECTOR. RELOCATE AS REQUIRED BASED ON NEW PARTITION LAYOUT.
ACCESS PANEL. REFER TO KEYNOTES
REFLECTED CEILING GENERAL NOTES
1. HATCHED AREA NOT IN CONTRACT - NO NEW WORK THIS AREA.
2. REFER TO ENGINEERING DRAWINGS FOR ADDITIONAL REQUIREMENTS
3. EXISTING HARD LID CEILINGTO REMAIN. PATCH AND REPAIR AS REQUIRED BY
ACCESS PANEL RELOCATION. REFER TO KEYNOTES.
4. PROVIDE NEW AREA OF DRYWALL CEILING AT ELEVATION TO MATCH EXISTING AT OFFICE 102. REFER TO
KEYNOTES.
5. REFER TO ENGINEERING DRAWINGS FOR ALL SWITCHING.
ARCHITECTURAL GENERAL NOTES
1. REFER TO GENERAL NOTES AND SPECIFICATIONS.
2. HATCHED AREA NOT IN CONTRACT. IT SHALL BE ASSUMED THAT THE DEMISING WALL BETWEEN OUR SCOPE OF
WORK AND EXISTING TENANT IS ALREADY IN PLACE. GC IS RESPONSIBLE FOR 1-SIDE OF ROCK ONLY.
3. PATCH AND REPAIR EXISTING PARTITIONS WHERE DEMOLITION HAS OCCURED, INCLUDING THE REMOVAL OF
WALL OUTLETS, BLANK COVER PLATES, AND THERMOSTATS. REPAIR DRYWALL AND PREPARE FOR SPECIFIED
FINISH.
4. WHERE NEW ELEMENTS ARE ADJACENT TO EXISTING ELEMENTS, ALIGN FINISHED SURFACES, UNLESS NOTED
OTHERWISE.
5. WHERE NEW PARTITION IS SHOWN PERPENDICULAR TO PERIMETER MULLION, CENTER PARTITION ON MULLION
USING BUILDING STANDARD CONNECTION DETAIL. FOR RATED CONDTITIONS. REFER TO DETAIL SHEET.
6. NOTIFY ARCHITECT OF ANY AREAS WHERE DIMENSIONAL REQUIREMENTS CANNOT BE MET OR EXCEED
DIMENSIONS SHOWN FOR CLARIFICATION.
7. ALL NEW DOOR LOCATIONS ARE TO HAVE 18" CLEAR ON PULL SIDE AND 12" CLEAR ON PUSH SIDE TO MEET ANSI
REQUIREMENTS. NOTIFY ARCHITECT OF ANY DOOR LOCATIONS NOT MEETING THIS REQUIREMENT PRIOR TO
ROUGH-IN.
8. ALL NEW DOOR LOCATIONS ARE TO HAVE 6" CLEAR (TYP.) ON HINGE SIDE, UNLESS NOTED OTHERWISE.
9. DOOR PREP FOR ACCESS CONTROL DEVCIES IS BY GENERAL CONTRACTOR. ELECTRIC HARDWARE AND
INSTALLATION OF HARDWARE (AND LOW VOLTAGE WIRING) IS BY TENANTS SECURITY VENDOR. COORDINATE WITH
TENANT'S SECURITY VENDOR.
10. COORDINATE HARDWARE FINISH WITH TENANT ACCESS CONTROL VENDOR.
11. PROTECT FLOOR COVERING TO REMAIN FROM DAMAGE DURING DEMOLITION AND NEW CONSTRUCTION.
12. REFER TO DOOR SCHEDULE FOR NEW DOORS THROUGHOUT. DOORS SHALL BE 2-PANEL PROFILE BY TRUSTILE
WITH CUST WOOD FRAME. STAIN TO MATCH ARCH SAMPLE.
13. STUD SIZE AT ALL NEW PARTITIONS SHALL MATCH EXISTING/ADJACENT.
POWER / COMMUNICATION GENERAL NOTES
1. REFER TO GENERAL NOTES AND SPECIFICATIONS.
2. HATCHED AREA NOT IN CONTRACT.
3. REFER TO ENGINEERING DRAWINGS FOR ADDITIONAL REQUIREMENTS.
4. ALL ELECTRICAL DEVICES SHOWN ARE NEW (N) UNLESS NOTED AS 'E' (EXISTING TO REMAIN) OR SHOWN
DASHED (TO BE REMOVED).
5. ALL NEW POWER & COMMUNICATIONS DEVICES TO BE INSTALLED AT HEIGHT AND ORIENTATION TO MATCH
EXISTING DEVICES, UNLESS NOTED OTHERWISE.
6. ALL ACCESS CONTROL DEVICES TO BE UNDER SEPARATE PERMIT. COORDINATE WITH TENANT'S SECURITY
VENDOR.
7. REPAIR ALL WALL SURFACES WHERE WALL-MOUNTED DEVICES ARE REMOVED DURING DEMOLITION.
8. REVIEW ALL THERMOSTAT LOCATIONS WITH ARCHITECT PRIOR TO INSTALLATION. REFER TO ENGINEERING
DRAWINGS.
9. REFER TO ENGINEERING DRAWINGS FOR POWER TO PLENUM-MOUNTED EQUIPMENT.
12. REFER TO ENGINEERING DRAWINGS AND KEYNOTES FOR EQUIPMENT SPECIFICATIONS/INFORMATION.
10. ALL NEW PHONE AND COMMUNICATIONS CABLING COVERPLATES AND TERMINATIONS TO BE BY CABLING
SUBCONTRACTOR
11. REMOVE ALL DATA AND COMMUNICATION CABLING EXCEPT DATA AND COMMUNICATION CABLING WHICH MAY
PASS THROUGH THIS FLOOR AND SERVICE OTHER TENANTS. OBTAIN FURTHER CLARIFICATION FROM LANDLORD
IF REQUIRED. LEAVE CABLING OF SUFFICIENT LENGTH AT ANY EXISTING LOCATIONS SHOWN TO REMAIN TO BE
USED AS PULL CABLE BY CABLING VENDOR..
12. FIELD COORDINATE ANY EXISTING DEVICES TO REMAIN AND ANY DEVICES TO BE REMOVED NOT SHOWN
HERE.
WALL MOUNTED DUPLEX OUTLET
WALL MOUNTED FOURPLEX OUTLET
WALL MOUNTED DEDICATED DUPLEX OUTLET
WALL MOUNTED 220V DUPLEX OUTLET
CEILING MOUNTED DUPLEX OUTLET
CEILING MOUNTED FOURPLEX OUTLET
FLUSH FLOOR MOUNTED DUPLEX OUTLET
FLUSH FLOOR MOUNTED FOURPLEX OUTLET
FLUSH FLOOR MOUNTED DUPLEX OUTLET
WALL MOUNTED VOICE/DATA ROUGH-IN BOX
CEILING MOUNTED VOICE/DATA RECEPTACLE
FLUSH FLOOR MOUNTED VOICE/DATA RECEPTACLE
WALL MOUNTED JUNCTION BOX
FLUSH FLOOR MOUNTED JUNCTION BOX
WALL MOUNTED COAXIAL CONNECTION
POWER & COMMUNICATIONS LEGEND
DEVICES ARE NOTED 'N' FOR NEW, 'E' FOR EXISTING,
'D' OR SHOWN DASHED TO BE REMOVED
123456789101112131415
A
B
C
D
E
F
G
H
I
J
K
Proj. No.:
Date:
Drawn By:
Sheet No.:
Scale:
P.M.:
Checked:
File Name:
ALL DIMENSIONS AND CONDITIONS MUST BE CHECKED AND
VERIFIED ON SITE BY THE CONTRACTOR AND SUBCONTRACTORS.
THE PROJECT MANAGER SHALL BE NOTIFIED IN WRITING OF ANY
DISCREPANCIES PRIOR TO PROCEEDING WITH THE WORK.
COPYRIGHT ACQUILANO LESLIE INC. ALL RIGHTS RESERVED
PROJECT NAME
ACQUILANOLESLIEINC.
architecturei nteriordesignarchitectureinteriordesign
1600STOUTSTREET
SUITE200
DENVER,COLORADO80202
TEL:303.893.5355
FAX:303.893.6840
DESIGN@ACQ UILANO.COM
__________
WWW.ACQUILANO.COM
As indicated
9/18/2012 3:43:56 PM
12 Vail Road
Vail, Colorado
1A2-1
ARCH/POWER/RCP
12-23A
09/10/12
AuthorChecker
Approver
Bill Esrey Office
DescriptionNo.Date
3/16" = 1'-0"1 1A2-1 (ARCH)
DOOR SCHEDULE
DOOR #WIDTHHEIGHT
HARDWARE
GROUP Fire RatingDOOR FINISHFRAME FINISHFRAME TYPEDoor Notes
100B3' - 0"7' - 10"1.6.1-TRUSTILE
2-PANEL DOOR -
TS2170
STARKE WOOD
CASING #2097
WOOD
1023' - 0"7' - 10"1.2.1-TRUSTILE
2-PANEL DOOR -
TS2170
STARKE WOOD
CASING #2097
WOOD
1012' - 6"7' - 10"1.1.1-TRUSTILE
2-PANEL DOOR -
TS2170
STARKE WOOD
CASING #2097
WOOD
1032' - 0"7' - 10"1.1.1-TRUSTILE
2-PANEL DOOR -
TS2170
STARKE WOOD
CASING #2097
WOOD
1043' - 0"7' - 10"1.1.1-TRUSTILE
2-PANEL DOOR -
TS2170
STARKE WOOD
CASING #2097
WOOD
100A3' - 0"7' - 10"1.9.1-EXISTING TO
REMAIN
EXISTING TO
REMAIN
FRAMELESS
3/16" = 1'-0"2 1A3-1 (POWER)
3/16" = 1'-0"3 1A4-1 (RCP)
KEYNOTE
5.1RELOCATED ACCESS PANEL. REFER TO GENERAL NOTES.
6.1PROVIDE BLOCKING IN PARTITIONS FOR WALL MOUNTED TELEVISION. COORDINATE HEIGHT WITH ARCH.
6.2PROVIDE AND INSTALL NEW WOOD VALANCE TO CONCEAL WINDOW TREATMENTS BY OTHERS. REFER TO RCP & DETAILS.
16.2RELOCATE ALL POWER AND DATA DEVICES LOCATED IN EXISTING WALL BASE, TO DIRECTLY ABOVE NEW WALL BASE AND BELOW
WINDOW SILL.
KEYNOTE
5.1RELOCATED ACCESS PANEL. REFER TO GENERAL NOTES.
6.1PROVIDE BLOCKING IN PARTITIONS FOR WALL MOUNTED TELEVISION. COORDINATE HEIGHT WITH ARCH.
6.2PROVIDE AND INSTALL NEW WOOD VALANCE TO CONCEAL WINDOW TREATMENTS BY OTHERS. REFER TO RCP & DETAILS.
16.2RELOCATE ALL POWER AND DATA DEVICES LOCATED IN EXISTING WALL BASE, TO DIRECTLY ABOVE NEW WALL BASE AND BELOW WINDOW SILL.
KEYNOTE
5.1RELOCATED ACCESS PANEL. REFER TO GENERAL NOTES.
6.1PROVIDE BLOCKING IN PARTITIONS FOR WALL MOUNTED TELEVISION. COORDINATE HEIGHT WITH ARCH.
6.2PROVIDE AND INSTALL NEW WOOD VALANCE TO CONCEAL WINDOW TREATMENTS BY OTHERS. REFER TO RCP & DETAILS.
16.2RELOCATE ALL POWER AND DATA DEVICES LOCATED IN EXISTING WALL BASE, TO DIRECTLY ABOVE NEW WALL BASE AND BELOW WINDOW SILL.
HARDWARE SCHEDULE
GROUP#RATINGHARDWARE COMPONENTSSECURITY COMPONENTSNOTES
ENTRY
1.6.11-1 ENTRY LOCKSET; 2 PAIR HINGES; 1 CLOSER; WALL or FLOOR STOP; 1 SET
SILENCERS
GLASS
1.9.11-EXISTING TO REMAIN.EXISTING TO REMAIN.EXISTING TO REMAIN
OFFICE
1.2.11-1 OFFICE LOCKSET; 2 PAIR HINGES; 1 WALL or FLOOR STOP; 1 SET
SILENCERS
PASSAGE
1.1.13-1 PASSAGE SET; 2 PAIR HINGES; 1 WALL or FLOOR STOP; 1 SET SILENCERS
By David Rhoades at 9:51 am, Nov 12, 2012