Loading...
HomeMy WebLinkAboutF12-0057 resubmit stamped approved page 1YOGABATH003 MAIN STAIR001UNFINISHEDBASEMENTMECHANICALROOM005LAUNDRY111KITCHEN107PANTRY108CLOSET114 PLAYROOM201 SITTING304MASTER2301MAIN STAIR001 MAIN STAIR001 UPPER LEVEL 2 T.O. PLYWOODELEVATION=115'-9" (7963.42')UPPER LEVEL 1 T.O. PLYWOODELEVATION=110'-0" (7957.67')MAIN LEVEL T.O. PLYWOODELEVATION=100'-0" (7947.67')MASTER 1 LEVEL T.O. PLYWOODELEVATION=105'-0" (7952.67')UPPER LEVEL 3 T.O. PLYWOODELEVATION=119'-0" (7966.67')5 12 5151 Bannock St. Denver, CO 80216 303-291-1012 303-383-5023 FAX firesprinkler@afssco.com A FIRE SPRINKLER DESIGN COMPANY MILE HIGH DESIGN GROUP MI S - R E P R E S E N T T H E E X A C T L A Y O U T O F T H E LA Y O U T & C A L C U L A T I O N S . AI D T H E A U T H O R I T Y H A V I N G J U R I S D I C T I O N W I T H SP R I N K L E R S C H E M A T I C M A Y I N S O M E C A S E S SP R I N K L E R S Y S T E M . I T I S I N T E N D E D T O H E L P ACCEPTING THIS COPY IS DEEMED AS AGREEING TO THE FOLLOWING: THIS DRAWING COPY, ITS CONTENTS,INFORMATION AND PRINCIPALS OF DESIGN ARE THE EXCLUSIVE PROPERTY OF THE FIRE PROTECTIONCONTRACTOR LISTED AND MILE HIGH DESIGN GROUP, LLC AND IS BEING SUBMITTED TO YOU WITH THEUNDERSTANDING THAT IT IS NOT TO BE REPRODUCED, COPIED OR MODIFIED IN ANY MANNER; NEITHER SHALLIT BE RELAYED IN WHOLE OR IN PART TO ANY OTHER INDIVIDUAL OR FIRM FOR ANY OTHER PROJECT OREXTENSION OF THIS PROJECT EXCEPT THRU WRITTEN AGREEMENT WITH THE FIRE PROTECTION CONTRACTORAND MILE HIGH DESIGN GROUP, LLC. ERRORS AS A RESULT OF THIS FILE BEING ELECTRONICALLYTRANSMITTED ARE BEYOND THE CONTROL OF AND ARE NOT THE RESPONSIBILITY OF THE FIRE PROTECTIONCONTRACTOR OR MILE HIGH DESIGN GROUP. MILE HIGH DESIGN GROUP IS NOT RESPONSIBLE FORINSTALLATION OR INSPECTION OF WORK INSTALLED. THESE PLANS ARE DIAGRAMMATICAL ONLY. ON SITECOORDINATION MUST BE ARRANGED WITH ALL OBSTRUCTIONS, i.e.: MECHANICAL, ELECTRICAL, ANDSTRUCTURAL. ANY ALTERATIONS FROM ENGINEERED DRAWINGS MUST BE APPROVED BY MILE HIGH DESIGNGROUP. MILE HIGH DESIGN GROUP IS NOT RESPONSIBLE FOR LAYOUT DESIGN ISSUES OR CONFLICTS WITHANY OBSTRUCTIONS. IF ADDITIONAL FIRE SPRINKLER PIPING AND/OR FIRE SPRINKLER HEADS ARE REQUIREDTHIS WILL BE THE RESPONSIBILITY OF THE FIRE SPRINKLER CONTRACTOR. ALL CHANGES MUST ME APPROVEDBY MILE HIGH DESIGN GROUP, LLCTHE OWNER IS RESPONSIBLE TO PROVIDE SUFFICIENT HEAT THROUGHOUT THIS BUILDING TO PREVENTFREEZING OF WATER IN THE FIRE SPRINKLER SYSTEM - TH I S S E T O F F I R E S P R I N K L E R S H O P DR A W I N G S H A V E B E E N R E V I E W E D AN D F O U N D T O B E A C C E P T A B L E B Y TI M O T H Y N . T R O S T E L , J R - N . I . C . E . T . IV # 1 0 2 0 5 5 . S R . E N G I N E E R I N G TE C H N I C I A N - F I R E P R O T E C T I O N NA T I O N A L I N S T I T U T E F O R C E R T I F I C A T I O N I N EN G I N N E R I N G T E C H N O L O G I E S __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ / _ _ _ _ / _ _ _ _ GA R A G E Flush212" SingleFDC Horn &StrobeCheckValve 2" c p v c p i p e si d e w a l l h e a d 4" - 6 " u n d e r g a r a g e d o o r pe n d e n t h e a d in c e i l i n g 1" v a l v e t o t e s t an t i f r e e z e 2" c o p p e r 6 h e a d s T/ S T/ S FDC Detailnot to scale Ri s e r D e t a i l no t t o s c a l e SECTION VIEW AFIRE SPRINKLER PLAN1/8" = 1'-0" TH I S A N T I F R E E Z E S Y S T E M W I L L H O L D A P R O X 3 0 g a l O F A N T I F R E E Z E S O L U T I O N PR E S S U R I Z E S Y S T E M T O 1 0 2 P S I O F A N T I F R E E Z E S O L U T I O N AN T I - F R E E Z E I S T O B E A P R E - M I X G L Y C E R I N S O L U T I O N . F R E E Z E P O I N T T O B E - 2 0 SO L U T I O N W I L L B E 4 8 % G L Y C E R I N A N D 5 2 % W A T E R PR O V I D E S I G N S T A T I N G A N T I F R E E Z E T Y P E , C O N C E N T R A T I O N AN D F R E E Z E P O I N T CO N T A C T I N F O F O R A N T I F R E E Z E S U P P L I E R G2 S O L U T I O N S 90 0 9 Q U I N C E S T R E E T , U N I T C HE N D E R S O N , C O 30 3 - 2 8 7 - 4 8 7 0 STEE L P I P E 39 t o t a l s p r i n k l e r s f o r t h i s j o b