HomeMy WebLinkAboutB12-0608 PLANS approvedINCIDENTAL STORAGE MERCANTILE EXIT LOAD = 1043 SF/30 SF PER OCC.= 35 OCC. + 2 OCC. = 37 OCCUPANTS 37 OCC.< 49: ONE EXIT OK PER IBC 1015.1 37 OCC. X 0.2"/OCC.= 7.4" MIN. EGRESS WIDTH < 72" PROVIDED EXIT LOAD = 74 SF/300 SF PER OCC.= 1 OCCUPANT 1 OCC. X 0.2"/OCC.= 0.2" MIN. EGRESS WIDTH < 36" PROVIDED 1 OCC.< 49: ONE EXIT OK PER IBC 1015.1 INSWING DOOR OK PER IBC 1008.1.2 INCIDENTAL USE (STORAGE) < 100 SF NO SEPARATION REQUIRED PER IBC 508.2.2 1043 SF MERCANTILE 74 SF INCIDENTAL STORAGE PUBLIC WAY TR A V E L D I S T A N C E = 5 6 ' - 2 " < 2 5 0 ' M A X P E R I B C 1 0 1 6 . 1 PROPOSED OAKLEY STORE LONGEST TRAVEL DISTANCE VIA ACCESSIBLE PATH TO RESTROOM FACILITY = 245' < 500' ALLOWED PER IPC 2902.4.1 EXISTING DRINKING FOUNTAIN EXISTING RESTROOMS Scale Project Number Date Drawn by Checked by On e W i l l o w B r i d g e R o a d , U n i t C - 3 Ea s t M e a d o w D r i v e , V a i l , C o l o r a d o 8 1 6 5 7 As indicated 11 / 2 1 / 2 0 1 2 1 2 : 1 2 : 4 9 P M A100 PROJECT INFORMATION 20112 VAIL OWB OAKLEY SSV 21 November 2012 PT PT GENERAL NOTES 2 1 3 4 Sht. No. ABBREVIATIONS PROJECT TEAM REGULATORY INFORMATION PROJECT DESCRIPTION DRAWING INDEXSYMBOLS LEGENDVICINITY MAP ADJUSTABLEADJ. WITHW/INSULATIONINS. LAMINATE INTERIORINT. LAM. WINDOW WD. WIN. WOOD SQUARESQ.EACHEA. FOOTINGFTG. GYPSUM BOARD HORIZONTAL HANDICAPPED AND AIR CONDITIONING HEATING, VENTILATING HEIGHT HVAC. H.C. HOR. HGT. GAUGE FURRING FUTURE GA. FURR. GYP. BD. FUT. EXTERIOR ELECTRICAL ELEVATION FLOOR (ING) FOOT OR FEET FOUNDATION FLOOR DRAIN FINISH FT. F.D. FIN. FLR. FDN. EQUAL EXT. EL. EQ. ELEC. TOP OF STEELT.O.S. TYPICAL UNLESS NOTED OTHERWISE UNDERWRITERS LABORATORIES VERTICAL UNFINISHED WATER RESISTANT UNF. W.R. VERT. U.L. TYP. U.N.O. STRUCTURAL STANDARD TOP OF CURB TOP OF WALL TONGUE AND GROOVE TOP OF CONCRETE THRESHOLDT-HOLD T.O.W. T. T.C T.&G. T.O.C. TREAD STL. STR. STD. STEEL CONCRETECONC. DIAMETER CONTINUOUS DIMENSION DOWN DOOR EXISTING DRAWING (E) DIM. DN. DWGS DR. DETAIL DOUBLE CENTER DET. DIA. CONT. DBL. CTR. BLOCKING ARCHITECTURAL BASEMENT BOT.BOTTOM COLUMN BEARING CEILING COL. BRG. CLG. BSMT. BEAM BUILDING BLKG. BM. ARCH. BLDG. REFERENCE RADIUS REVISE (D), REVISION ROUGH OPENING SIMILAR SECTION SPECIFICATION REFLECT (ED) (IVE) RM. SPEC. SHT. SEC. SIM. SHEET ROOM R. R.O. RE RFL. REV. RAD. RISER ON CENTER OVERALL OVERHEAD OPENING PAINT (ED) PLYWOOD POUNDS PER SQ. IN. PRESSURE TREATED POUNDS PER SQ. FT.P.S.F. PT PL. P.S.I. P.WD. PNT. PLATE O.A. O.C. OH. OPG. CENTERLINE ACCESS PANEL ABOVE FINISHED FLOOR EXISTING A.P. (E) A.F.F. LC MECHANICAL MINIMUM MISCELLANEOUS NOT TO SCALE MANUFACTURER MIN. MFR. N.T.S. MISC. MECH. FINISH FLOOR TAG WALL TAG ROOM TAG INTERIOR ELEVATION TAG DOOR TAG TODD ARCHITECTURE, LLC PAUL TODD - PRINCIPAL 1521 15TH STREET DENVER, CO 80202 303-446-0460 866-519-3953 (FAX) EMAIL: paul@toddarchitecture.com COMP/DATA RECEPTACLE QUADPLEX RECEPTACLE TELE/COMM RECEPTACLE CEILING MOUNTED DUPLEX RECEPTACLE ROOM NAME 101 10 SPECIALTY SPORTS VENTURE JOE WALKER - REGIONAL MANAGER 492 EAST LIONSHEAD CIRCLE, SUITE 101 VAIL, CO 81657 970-476-9457 970-476-9427 (FAX) EMAIL: jwalker@ssv.net ARCHITECT: TENANT: GENERAL A100 PROJECT INFORMATION ARCHITECTURAL A101 PLANS & ELEVATIONS A102 ELEVATIONS, SCHEDULES, & DETAILS A103 DETAILS MECHANICAL M100 MECHANICAL PLAN & SPECIFICATIONS ELECTRICAL E001 ELECTRICAL SPECIFICATIONS AND LEGEND E002 ONE-LINE DIAGRAM & SCHEDULES E100 POWER PLAN & LIGHTING PLAN ADDRESS ONE WILLOW BRIDGE ROAD #C-3 VAIL, COLORADO 81657 PARCEL NUMBER 2101-082-84-025 LEGAL DESCRIPTION SUBDIVISION: ONE WILLOW BRIDGE COMMERCIAL UNIT: C3 OWNER ONE WILLOW BRIDGE COMMERCIAL LLC 141 EAST MEADOWS DRIVE SUITE 211 VAIL, COLORADO 81657 PROJECT SCOPE THIS PROJECT CONSISTS OF INTERIOR TENANT IMPROVEMENT WORK ON ONE LEVEL OF AN EXISTING STRUCTURE. THE WORK DOES NOT INVOLVE EXTERIOR MODIFICATIONS, A CHANGE OF USE, OR ADDITIONAL AREA. THE SCOPE OF WORK INCLUDES INTERIOR PARTITIONS, WIRING FOR NEW ELECTRICAL FIXTURES AND DATA LINES, NEW MECHANICAL FCU AND DISTRIBUTION, NEW PAINT AND INTERIOR FINISHES, AND NEW DISPLAY COUNTERS AND STORE FIXTURES PROJECT LOCATION ELECTRIC WATER COOLEREWC North 1. THE CONTRACTOR IS RESPONSIBLE FOR THE PAYMENT FOR AND ACQUISITION OF ALL REQUIRED PERMITS AND FEES ASSOCIATED WITH HIS/HER PORTION OF THE PROJECT. 2. THE CONTRACTORS SHALL CONFIRM THE LOCATION OF ALL EXISTING UTILITIES AND COORDINATE THE INSTALLATION OF ALL NEW UTILITIES AND METER LOCATIONS WITH THE UTILITY COMPANY OR GOVERNMENTAL AUTHORITY HAVING JURISDICTION OVER THE PROJECT. 3. IT IS THE CONTRACTOR'S SOLE RESPONSIBILITY TO THOROUGHLY REVIEW AND BECOME FAMILIAR WITH ALL PERTINENT DOCUMENTS AVAILABLE REGARDING THE CONSTRUCTION OF THIS PROJECT. ANY AMBIGUITY OR DISCREPANCY DISCOVERED IN THE DOCUMENTS SHALL BE IMMEDIATELY REPORTED TO THE ARCHITECT WHO SHALL MAKE CLARIFICATIONS AND INTERPRETATIONS IN A TIMELY MANNER. THE CONTRACTOR'S FAILURE TO DISCOVER AND NOTIFY THE ARCHITECT OF SAID AMBIGUITY OR DISCREPANCY PRIOR TO THE START OF CONSTRUCTION SHALL NOT RELIEVE THE CONTRACTOR OF RESPONSIBILITY RELATING TO THE MATTER. 4. CHANGES OR DEVIATIONS FROM THE DOCUMENTS, MADE BY THE CONTRACTOR OR THEIR SUPPLIERS, WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT, ARE UNAUTHORIZED CHANGES TO THE WORK AND AS SUCH SHALL RELIEVE THE ARCHITECT OF ALL RESPONSIBILITY FOR THE CONSEQUENCES ARISING THEREFROM. 5. PRIOR TO BEGINNING ANY NEW WORK OR INSTALLATION, IT IS THE CONTRACTOR'S RESPONSIBILITY TO INSPECT PREVIOUSLY INSTALLED WORK AND/OR SUBSTRATE AND VERIFY THAT ALL SUCH WORK IS SATISFACTORY AND COMPLETE TO THE REQUIRED LEVEL OF ACCEPTANCE TO ALLOW FOR THE START OF SUBSEQUENT WORK. THE COMMENCEMENT OF ANY WORK SHALL INDICATE THAT ALL PREVIOUSLY INSTALLED WORK AND/OR SUBSTRATE WAS FOUND TO BE ACCEPTABLE AND INSTALLED ACCORDING TO INDUSTRY STANDARDS. ANY WORK FOUND TO BE IN UNACCEPTABLE CONDITION SHALL BE REMOVED AND REPLACED AT NO ADDITIONAL COST TO THE OWNER OR TENANT. 6. THE CONTRACTOR(S) SHALL VISIT THE PROJECT SITE PRIOR TO ESTIMATING THE COST OF THE SCOPE OF WORK AND PRIOR TO ORDERING OR FABRICATING MATERIALS OR BEGINNING ANY CONSTRUCTION RELATED ACTIVITIES FOR THE PURPOSE OF BECOMING COMPLETELY FAMILIAR WITH THE SITE AND ALL EXISTING CONDITIONS WHICH MIGHT IMPACT THE COST OF, OR PERFORMANCE OF THE SCOPE OF WORK. 7. ALL CONSTRUCTION IS TO BE PERFORMED IN ACCORDANCE WITH ALL APPLICABLE CODES AND THE REQUIREMENTS OF ALL REGULATORY AGENCIES HAVING JURISDICTION OVER THE PROJECT. UNDER NO CONDITION DOES THE ARCHITECT HAVE RESPONSIBILITY FOR THE MEANS OR METHODS USED BY THE CONTRACTOR IN THE PERFORMANCE OF THE WORK OR FOR CONDITIONS OF SAFETY AT THE JOB SITE. 8. THE CONTRACTOR SHALL COORDINATE ALL FINISHES, MATERIALS, AND COLORS WITH THE ARCHITECT, GENERAL CONTRACTOR, OWNER AND TENANT. 9. ALL EXPOSED STEEL SURFACES THAT ARE WELDED ARE TO BE GROUND SMOOTH, PRIMED AND PAINTED. 10.DIMENSIONS OF AND FROM EXISTING CONDITIONS HAVE BEEN TAKEN FROM EXISTING DRAWINGS AND/OR FIELD MEASUREMENTS. ALL EXISTING DIMENSIONS ARE TO FINISH FACE UNLESS NOTED OTHERWISE ON DRAWINGS. THE CONTRACTOR(S) SHALL FIELD VERIFY ALL DIMENSIONS PERTAINING TO THE EXISTING CONDITIONS, INCLUDING ALL WORK ALREADY IN PLACE, PRIOR TO ORDERING OR FABRICATING MATERIALS, AND PRIOR TO START OF CONSTRUCTION. 11. IF, DURING THE COURSE OF ANY REQUIRED DEMOLITION WORK PERFORMED BY THE CONTRACTOR(S), OWNERS, OR OTHERS UNDER THE TERMS OF THE SUBCONTRACT OR OTHER AGREEMENT, HAZARDOUS WASTE IS ENCOUNTERED, SAME SHALL BE REMOVED AND DISPOSED OF AS REQUIRED BY THE AUTHORITIES HAVING JURISDICTION OVER THE PROJECT. THE ARCHITECT AND GENERAL CONTRACTOR IS NOT KNOWLEDGEABLE OF THE EXISTENCE OF HAZARDOUS WASTE AND SHALL NOT BE HELD RESPONSIBLE FOR THE EXISTENCE OR REMOVAL OF HAZARDOUS WASTE. 12. THE CONTRACTOR(S) SHALL KEEP PREMISES FREE FROM ACCUMULATION OF WASTE MATERIALS AND DEBRIS. 13. ALL DIMENSIONS OF NEW WALLS ARE TO FACE OF FRAMING UNLESS NOTED OTHERWISE ON DRAWING. 14. DO NOT SCALE THE DRAWINGS, IF QUESTIONS ARISE AS TO DIMENSIONAL REQUIREMENTS, CONTACT THE ARCHITECT FOR CLARIFICATION. 15. ITEMS OF EQUIPMENT OR CONSTRUCTION NOTED N.I.C. ARE NOT TO BE PROVIDED UNDER THE CONTRACT, AND UNLESS NOTED OTHERWISE SHALL BE FURNISHED AND INSTALLED BY OWNER'S SEPARATE CONTRACT. 16. ALL MATERIALS, FIXTURES AND EQUIPMENT PROVIDED UNDER THIS CONTRACT ARE TO BE PROVIDED IN NEW CONDITION WITH FULL MANUFACTURER'S WARRANTY, UNLESS NOTED OTHERWISE, AN ARE TO BE STORED AND INSTALLED PER THE MANUFACTURER'S SPECIFICATIONS. DAMAGED ITEMS SHALL BE REPLACED AT NO ADDITIONAL COST TO THE OWNER. 17. PROVIDE WATER RESISTANT SHEET ROCK AT ALL APPLICATIONS WHICH MAY BE SUBJECT TO THE ADVERSE EFFECTS OF MOISTURE. 18. CONTRACTOR IS RESPONSIBLE FOR DETERMINING APPROPRIATE FILL MATERIAL FOR FLOOR INFILL SUITABLE FOR EXISTING STRUCTURAL CAPACITY AND PROPOSED FLOOR FINISHES. 19. INSTALL PORTABLE FIRE EXTINGUISHERS PER LOCAL CODE. LOCAL FIRE MARSHALL TO CONFIRM LOCATIONS WITH GENERAL CONTRACTOR. 20. NORTH ARROWS AS DEPICTED ON DRAWING SET ARE FOR PROJECT REFERENCE ONLY. CONTRACTORS ARE RESPONSIBLE FOR VERIFYING ORIENTATION OF PROJECT SITE AND SCOPE OF WORK TO BE COMPLETED PRIOR TO START OF WORK. JURISDICTIONS BUILDING THE TOWN OF VAIL FIRE VAIL FIRE DEPARTMENT APPLICABLE CODES ARCHITECTURAL 2009 INTERNATIONAL BUILDING CODE MECHANICAL 2009 INTERNATIONAL MECHANICAL CODE PLUMBING 2009 INTERNATIONAL PLUMBING CODE ELECTRICAL 2008 NATIONAL ELECTRICAL CODE FUEL GAS 2009 INTERNATIONAL FUEL GAS CODE FIRE PROTECTION 2009 INTERNATIONAL FIRE CODE ENERGY 2009 INTERNATIONAL ENERGY CONSERVATION CODE AMENDMENTS TOWN OF VAIL ORDINANCE NO. 18 SERIES OF 2009 ACCESSIBILITY 2003 ICC/ANSI A117.1 BUILDING INFORMATION CONSTRUCTION TYPE II-A FIRE PROTECTION FULLY SPRINKLERED USE AND OCCUPANCY CLASSIFICATION MERCANTILE (RETAIL STORE)GROUP M ELECTRICAL ENGINEER MECHANICAL ENGINEER CHRISTOPHER MENGES ENGINEERING JEFF BELLMAN 1100 WEST LITTLETON BLVD., SUITE 400 LITTLETON, CO 80120 720-283-3018 720-283-6253 (FAX) EMAIL: jeff@mengeseng.com KAZIN & ASSOCIATES BRYAN KAZIN 9364 TEDDY LANE, SUITE 101 LONE TREE, CO 80124 720-489-1609 720-489-1611 (FAX) EMAIL: bryan@kazinengineer.com 1/8" = 1'-0"A100 1 AREA & CODE PLAN 1" = 40'-0"A100 2 RESTROOM FACILITY DIAGRAM 0'4'8'16'32' North North GENERAL INTERIOR FINISH NOTES Where materials are applied on wa1ls, ceilings or structural elements required to have a fire-resistance rating or to be of noncombustible construction, they shall comply with the provisions of this section. Direct attachment and furred construction. Where walls and ceilings are required for any provision in this code to be of fire-resistance-rated or noncombustible construction, the interior finish material shall be applied directly against such construction or to furring strips not exceeding 1.75 inches (44 mm) applied directly against such surfaces. The intervening spaces between such furring strips shall be filled with inorganic or Class A material or shall be fireblocked at a maximum of 8 feet (2438 mm) in any direction in accordance with Section 717. Set-out construction. Where walls and ceilings are required to be of fire-resistance-rated or noncombustible construction and walls are set out or ceilings are dropped distances greater than specified in Section 803.4.1. Class A finish materials shall be used except where interior finish materials are protected on both sides by an automatic sprinkler system or attached to noncombustible backing or furring strips installed as specified in Section 803.4.1. The hangers and assembly members of such dropped ceilings that are below the main ceiling line shall be of noncombustible materials, except that in Type III and V construction, fire-retardant-treated wood shall be permitted. The construction of each set-out wall shall be of fire-resistance-rated construction as required elsewhere in this code. Materials. An interior wall or ceiling finish that is not more than 0.25 inch (6.4 mm) thick shall be applied directly against a noncombustible backing. INTERIOR WALL AND CEILING FINISH REQUIREMENTS FOR SPRINKLERED M AND B OCCUPANCIES EXIT ENCLOSURES/PASSAGEWAYS:CLASS B CORRIDORS:CLASS C ROOMS AND ENCLOSED SPACES:CLASS C DUCTS AND AIR TRANSFER OPENINGS Duct and air transfer openings shall comply with IBC Section 716. See Mechanical Drawings SAFETY GLAZING GENERAL NOTES Glazing in the following locations will be of safety glazing material and conform to IBC Section 2406.3: 1. Ingress and egress doors except jalousies. 2. Fixed and sliding panels of sliding door assemblies and panels in swinging doors other than wardrobe doors. 3. Unframed swinging doors. 4. Fixed or operable panels adjacent to a door where the nearest exposed edge of the glazing is within a 24-inch (610 mm) arc of either vertical edge of the door in a closed position and where the bottom exposed edge of the glazing is less than 60 inches (1525 mm) above the walking surface. 5. Individual fixed or operable panels, other than those locations described above, that meet all of the following conditions: a. Exposed area of an individual pane greater than 9 square feet (0.84 m2). b. Exposed bottom edge less than 18 inches (457 mm) above the floor. c. Exposed top edge greater than 36 inches (914 mm) above the floor. d. One or more walking surfaces within 36 inches (914 mm) horizontally of the plane of the glazing. 6. Walls enclosing stairway landings or within 5 feet (1525 mm) of the bottom and top of stairways where the bottom edge of the glass is less than 60 inches (1525 mm) above a walking surface. FIRE BLOCKING GENERAL NOTES Fire blocks should be provided in accordance with Section 717.1 in the following locations: 1. In concealed spaces of stud walls and partitions, including furred spaces, at the ceiling and floor levels. 2. In concealed spaces of stud walls and partitions, including furred spaces. At 10-foot (3048 mm) intervals along the length of the wall. 3. At all interconnections between concealed vertical and horizontal spaces such as occur at soffits, drop ceilings and cove ceilings. 4. In concealed spaces between stair stringers at the top and bottom of the run and between studs along and in line with the run of stairs if the walls under the stairs are unfinished. 5. In openings around vents, pipes, ducts, chimneys, fireplaces and similar openings that afford a passage for fire at ceiling and floor levels, with noncombustible materials. 6. At openings between attic spaces and chimney chases for factory-built chimneys. No.Description Date By David Rhoades at 1:14 pm, Nov 21, 2012 Reviewed for Code Compliance Code: 2009 International Building Code (IBC) By Martin Haeberle at 11:31 am, Nov 30, 2012 G.C. TO PATCH, FIRE CAULK, AND MAINTAIN FIRE RATING FOR EXIST. DEMISING WALLS INTERNALLY ILLUMINATED DOUBLE SIDED BLADE SIGN ABOVE DOOR EXIST. STOREFRONT WINDOWS AND DOORS, TYP. MIRROR FRAMES PROVIDED BY TENANT. MIRROR GLASS PROVIDED AND INSTALLED BY G.C. CUSTOM SHOP EYEWEAR FIXTURE PROVIDED BY TENANT OPEN EYEWEAR FIXTURE PROVIDED BY TENANT HINGED MIRROR FRAME TO ALLOW ACCESS TO EXISITING FIRE VALVE ELECTRICAL PANEL, SEE ELECTRICAL DWGS. ADJACENT TENANT PUBLIC WAY EXISTING STRUCTURAL COLUMN TO REMAIN. FURR OUT WITH 5/8" GYP. BD. OVER 20 GAUGE 3 5/8" MTL. STUDS @ 16" O.C., TYP. ADJACENT TENANT EXIST. STRUCTURAL COLUMN TO REMAIN 36" HIGH ACCESSIBLE CASHWRAP PROVIDED BY TENANT 30"x48" CLEAR FLOOR AREA MIRROR FRAME PROVIDED BY TENANT. MIRROR GLASS PROVIDED AND INSTALLED BY G.C. MIRROR FRAMES PROVIDED BY TENANT. MIRROR GLASS PROVIDED AND INSTALLED BY G.C. EXIST. STOREFRONT WINDOWS AND DOORS, TYP. G.C. TO PATCH, FIRE CAULK, AND MAINTAIN FIRE RATING FOR EXIST. DEMISING WALLS 5/8" TYPE X GYP. BD. W/LEVEL 4 FINISH OVER 20 GA. 3 5/8" MTL. STUDS, TYP. BUILT-IN BENCH PROVIDED BY TENANT AND INSTALLED BY G.C. 60" DIAMETER TURNING AREA 30"x48" CLEAR FLOOR AREA 1' - 10" FURR-OUT OVER EXISTING DOOR (ABANDONED IN PLACE) 5/8" DRYWALL OVER MTL. FURRING. FRAME DRYWALL JAMB, HEAD, AND SILL RETURNS AT EXISTING WINDOW AND DOOR OPENINGS, TYP. EXIST. FIRE VALVE 1 2 3 3 5/8" 1' - 2" 3 5/8" 3' - 7 3/8" 3 5/8" 3' - 6 1/8" BACKSTOCK 5 FITTING 4 ACCESSIBLE FITTING 3 DISPLAY 2 SALES FLOOR 1 4 3 5 / 8 " 4' - 7 3 / 8 " 3 5 / 8 " 6' - 7 3 / 8 " 3 5 / 8 " 2' - 0 3 / 4 " 3 5/8" 1' - 2" 3 5/8" 7' - 5 1/8" MIN. ALIGN. FURR-OUT WALL AS REQ'D. 3 5 / 8 " 1' - 3 3 / 8 " 3 5 / 8 " 9' - 1 3 / 8 " 3 5 / 8 " 1' - 3 3 / 8 " 3 5 / 8 " 4' - 7 3 / 8 " 3 5 / 8 " 1' - 3 3 / 8 " 3 5 / 8 " 5' - 3 1 / 4 " 3 5 / 8 " 1' - 1 3 / 4 " 3 5 / 8 " 14 ' - 5 1 / 2 " 3 5 / 8 " 1' - 3 3 / 8 " 3 5 / 8 " 9' - 1 5 / 8 " 3 5 / 8 " 1' - 7 3 / 4 " 2' - 0"5' - 6 5/8" 3 5/8" 1' - 3 3/8" 3 5/8" 7' - 3 3/4" 3 5/8" 1' - 2" 3 5/8" FLOOR TILE FLR4 OVER ANTI-FRACTURE MEMBRANE. FLOAT EXIST. CONCRETE FLOOR SLAB W/LEVELING COMPOUND 3 5 / 8 " 2' - 4 " PREFAB. PLASTIC LAMINATE COUNTER @ 30" AFF NOTE: ALL FLOOR AND WALL FIXTURES PROVIDED BY TENANT. G.C. TO PROVIDE ADD ALTERNATE INSTALLATION COST. A1015 4 6 OV E R A L L F I N I S H 9' - 0 1 / 4 " DISPLAY WALL W1 (1/2"x23-3/8"x83") DUROCK WALL PANELING PROVIDED BY G.C. W/ RECESSED STANDARDS, TYP. PROVIDED & INSTALLED BY TENANT FURR-OUT EXISTING COLUMN AS TIGHT AS POSSIBLE WITH 5/8" GYP. BD. OVER 1 1/2" MTL. STUDS TURNED FLAT GRAPHIC RAILS, TYP. SEE DETAIL REFER TO ELECT. DWGS. FOR HANGING OF LIGHT FIXTURES CENTER OVER END CABINETS OF CASHWRAP RECESSED LIGHT FIXTURES CEILING MOUNTED TRACK LIGHT ORIENT FIXTURE ROTATED 45 DEGREES RELATIVE TO WALLS, TYP. CENTER LIGHT FIXTURES ABOVE MIRROR GENERAL NOTES: 1.SEE MEP DRAWINGS FOR ADDITIONAL EQUIPMENT LOCATIONS 2.ALL ELEMENTS IN SPACE (I.E. MECH. DUCTS, DIFFUSERS, ELECT. CONDUITS, MOTION SENSORS, ETC.) SHALL BE MOUNTED AS HIGH AS POSSIBLE. NOTIFY ARCHITECT OF CONFLICTS. 3.ALL OAKLEY/ TENANT SUPPLIED ITEMS ARE TO BE PROVIDED AND INSTALLED BY TENANT. G.C. TO PROVIDE ADD ALTERNATE TO INSTALL OAKLEY/TENANT SUPPLIED ITEMS 4.MOUNT J-BOXES ABOVE CEILING 5.SPRINKLER HEADS IN GYP. CEILINGS/SOFFITS SHOULD BE FULLY RECESSED AND COVERED WITH METAL PLATES FINISHED TO MATCH ADJACENT SURFACE 9' - 0" AFF 10' - 6" AFF 5/8" GYP. BD. CEILING CLG1 WITH LEVEL 4 FINISH ATTACHED TO MTL. SUSPENSION SYSTEM. PAINT P2 9' - 0" AFF 9' - 0" AFF 9' - 0" AFF OPEN TO STRUCTURE 5/8" GYP. BD. CEILING CLG1 WITH LEVEL 4 FINISH ATTACHED TO MTL. SUSPENSION SYSTEM. PAINT P2 5/8" GYP. BD. CEILING CLG1 WITH LEVEL 4 FINISH ATTACHED TO MTL. SUSPENSION SYSTEM. PAINT P2 DISPLAY WINDOW 5/8" TYPE X GYP. BD. W/LEVEL 4 FINISH OVER 20 GA. 3 5/8" MTL. STUDS, TYP. BUILT-IN BENCH PROVIDED BY TENANT AND INSTALLED BY G.C. 30"x48" CLEAR FLOOR AREA BENCH 1' - 10" 1 2 3 3 5/8" 1' - 2" 3 5/8" 3' - 7 3/8" 3 5/8" 3' - 6 1/8" FITTING 4 ACCESSIBLE FITTING 3 DISPLAY 2 4 3 5/8" 1' - 2" 3 5/8" 7' - 5 1/8" MIN. 3 5 / 8 " 1' - 3 3 / 8 " 3 5 / 8 " 4' - 7 3 / 8 " 3 5 / 8 " 1' - 3 3 / 8 " 3 5 / 8 " CL E A R 2' - 6 " BE N C H 4' - 0 " CLEAR 4' - 0" A102 4 3 A102 5 60" DIA. CIRCULAR TURNING SPACE CLEAR OF DOOR IN OPEN POSITION 36" X 65" MIRROR FRAME PROVIDED BY TENANT. MIRROR GLASS PROVIDED AND INSTALLED BY G.C. ATTACHED DIRECTLY TO WALL. CAULK PERIMETER WITH CLEAR SILICONE 18" X 65" MIRROR FRAME PROVIDED BY TENANT. MIRROR GLASS PROVIDED AND INSTALLED BY G.C. ATTACHED DIRECTLY TO WALL. CAULK PERIMETER WITH CLEAR SILICONE OVERALL CLEAR 9' - 0" OPEN OPEN 10 ' - 6 " 9' - 0 " 5/8" GYP. BD. WITH LEVEL 4 FINISH OVER EXISTING PLYWOOD. PAINT P2 METAL BASE B1 METAL BASE B1 DISPLAY WALL W1 (1/2"x23-3/8"x83") DUROCK WALL PANELING PROVIDED BY G.C. W/ RECESSED STANDARDS, TYP. PROVIDED & INSTALLED BY TENANT MIRROR FRAMES PROVIDED BY TENANT. MIRROR GLASS PROVIDED AND INSTALLED BY G.C. CUSTOM EYEWEAR FIXTURE PROVIDED BY TENANT EXIST. STOREFRONT WINDOWS GYP. BD. RETURNS AT WINDOW JAMBS, TYPICAL GARMENT HOOKS FITTING ROOM DOOR BEYOND CLEAR OPENING 4' - 6" 6' - 9 " 5' - 0 " 1' - 0 " 1' - 0 " 5/8" GYP. BD. WITH LEVEL 4 FINISH OVER 20 GAUGE MTL. STUDS. PAINT P2 5/8" GYP. BD. WITH LEVEL 4 FINISH OVER 20 GAUGE MTL. STUDS. PAINT P2 5/8" GYP. BD. WITH LEVEL 4 FINISH OVER EXISTING PLYWOOD. PAINT P2 METAL BASE B1METAL BASE B1 DISPLAY WALL W1 (1/2"x23-3/8"x83") DUROCK WALL PANELING PROVIDED BY G.C. W/ RECESSED STANDARDS, TYP. PROVIDED & INSTALLED BY TENANT MIRROR FRAMES PROVIDED BY TENANT. MIRROR GLASS PROVIDED AND INSTALLED BY G.C. OPEN EYEWEAR FIXTURE PROVIDED BY TENANT 9' - 0 " 10 ' - 6 " 6' - 9 " EXIST. STOREFRONT WINDOWS GYP. BD. RETURNS AT WINDOW JAMBS, TYPICALFINISH OVERALL 9' - 0 1/4" 5/8" GYP. BD. WITH LEVEL 4 FINISH OVER EXISTING PLYWOOD. PAINT P2 METAL BASE B1 DISPLAY WALL W1 (1/2"x23-3/8"x83") DUROCK WALL PANELING PROVIDED BY G.C. W/ RECESSED STANDARDS, TYP. PROVIDED & INSTALLED BY TENANT MIRROR FRAME PROVIDED BY TENANT. MIRROR GLASS PROVIDED AND INSTALLED BY G.C. DISPLAY WALL W1 (1/2"x23-3/8"x83") DUROCK WALL PANELING PROVIDED BY G.C. W/ RECESSED STANDARDS, TYP. PROVIDED & INSTALLED BY TENANT 6' - 9 " METAL BASE B1 9' - 0 " 1' - 0 " 5/8" GYP. BD. WITH LEVEL 4 FINISH OVER 20 GAUGE MTL. STUDS. PAINT P2 HINGED MIRROR FRAME FOR FIRE VALVE ACCESS PROVIDED BY TENANT. MIRROR GLASS PROVIDED AND INSTALLED BY G.C. Scale Project Number Date Drawn by Checked by On e W i l l o w B r i d g e R o a d , U n i t C - 3 Ea s t M e a d o w D r i v e , V a i l , C o l o r a d o 8 1 6 5 7 As indicated 11 / 2 1 / 2 0 1 2 1 2 : 1 3 : 0 0 P M A101 PLANS & ELEVATIONS 20112 VAIL OWB OAKLEY SSV 21 November 2012 PT PT 1/4" = 1'-0"A101 1 FLOOR PLAN North 0'2'4'8'16' North 0'2'4'8'16' 1/4" = 1'-0"A101 2 CEILING PLAN 1/2" = 1'-0"A101 3 ENLARGED FITTING ROOM PLAN 1/4" = 1'-0"A101 4 EAST ELEVATION 1/4" = 1'-0"A101 5 WEST ELEVATION 1/4" = 1'-0"A101 6 SOUTH ELEVATION No.Description Date Separate permit required Reviewed for Code Compliance Code: 2009 International Building Code (IBC) By Martin Haeberle at 11:31 am, Nov 30, 2012 NESTING TABLE NESTING TABLE DISPLAY H RACK H RACK H RACK CUBE PEDESTAL ACCESSORY TOWER NESTING TABLE DISPLAY DISPLAY NESTING TABLE MANNEQUIN MANNEQUIN ACCESSORY TOWER CASHWRAP NESTING TABLE NESTING TABLE H RACK CUBE PEDESTAL OP E N E Y E W E A R CU S T O M S H O P E Y E W E A R NOTE: ALL FLOOR AND WALL FIXTURES PROVIDED BY TENANT. G.C. TO PROVIDE ADD ALTERNATE INSTALLATION COST. GRAPHIC RAILS, TYP. GRAPHIC RAIL GENERAL NOTES: •NO TILE SHALL BE LESS THAN 3" •TILE SHALL BE INSTALLED TO RUN UNDER WALL BASE •FLOAT FLOOR LEVEL WITH CEMENTITIOUS FILL •PROVIDE ANTI-FRACTURE MEMBRANE SYMBOL DENOTES FLOOR TRANSITION CERAMIC TILE FLR4 OVER ANTI-FRACTURE MEMBRANE. FLOAT EXIST. CONCRETE FLOOR SLAB W/LEVELING COMPOUND CARPET FLR3, BASE B1 CARPET FLR3, BASE B1 BASE B1, TYPICAL EXPOSED CONCRETE FLOOR FLR2, BASE B2 SALES FLOOR 1 DISPLAY 2 ACCESSIBLE FITTING 3 FITTING 4 BACKSTOCK 5 BASE B1, TYPICAL BASE B1, TYPICAL CARPET WALK-OFF MATT FLR1. PROVIDE RUBBER TILE/CARPET REDUCER/JOINER @ TILE TO CARPET TRANSITION 7' - 0" 6' - 0 " 35" X 56" MIRROR FRAME PROVIDED BY TENANT. MIRROR GLASS PROVIDED AND INSTALLED BY G.C. ATTACHED DIRECTLY TO WALL. CAULK PERIMETER WITH CLEAR SILICONE 1' - 0 " METAL BASE B1 EXISTING GYP. BD. REPAIR AND PATCH TO ACHIEVE LEVEL 4 FINISH. PAINT P2 BENCH PROVIDED AND INSTALLED BY TENANT. SECURE TO FLOOR CLEAR 2' - 6"4' - 0" 1' - 6 " 9' - 0 " LIGHT FIXTURE. SEE ELECT. DWGS. 1' - 2 " 1' - 0 " 36" X 65" MIRROR FRAME PROVIDED BY TENANT. MIRROR GLASS PROVIDED AND INSTALLED BY G.C. ATTACHED DIRECTLY TO WALL. CAULK PERIMETER WITH CLEAR SILICONE METAL BASE B1 5/8" GYP. BD. WITH LEVEL 4 FINISH OVER 20 GAUGE 3 5/8" MTL. STUDS AT 16" O.C. PAINT P2 6' - 7 " LIGHT FIXTURE. SEE ELECT. DWGS. ACCESS DOOR INTO DISPLAY AREA 4 TWO SETS OF (3) GARMENT HOOKS ON 24"x6" RAISED PANEL MOUNTED ON WEST WALL, PROVIDED AND INSTALLED BY TENANT. PROVIDE SOLID BACKING IN WALL 3' - 4 " 5' - 0 " 6' - 9 " METAL BASE B1 18" X 65" MIRROR FRAMES PROVIDED BY TENANT. MIRROR GLASS PROVIDED AND INSTALLED BY G.C. ATTACHED TO WALL AND CAULK PERIMETER WITH CLEAR SILICONE 1' - 0 " (3) GARMENT HOOKS ON 24"x6" RAISED PANEL MOUNTED ON EAST WALL, PROVIDED AND INSTALLED BY TENANT. PROVIDE SOLID BACKING IN WALL 5' - 0 " Scale Project Number Date Drawn by Checked by On e W i l l o w B r i d g e R o a d , U n i t C - 3 Ea s t M e a d o w D r i v e , V a i l , C o l o r a d o 8 1 6 5 7 1/4" = 1'-0" 11 / 2 1 / 2 0 1 2 1 2 : 1 3 : 0 8 P M A102 ELEVATIONS, SCHEDULES, & DETAILS 20112 VAIL OWB OAKLEY SSV 21 November 2012 PT PT DOOR SCHEDULE MARK TYPE WIDTH THICKNESS HEIGHT MATERIAL FINISH FRAME TYPE FRAME FINISH HARDWARE FIRE RATING COMMENTS 1 FITTING ROOM 3' - 0"1 3/4"5' - 0"HC MTL. DOOR PAINT P3 WELDED STL. (CASED OPENING) PAINT P3 ENTRY LOCK: SCHLAGE "L" SERIES LEVER 03B TRIM, 626 FINISH, LATCHING HARDWARE L9453, KEYED LEVER; HINGES: (3) 4" 450 T88; FLOOR STOP: W1276 1/2” DOME NON-RATED (3) CLOTHES HOOKS ON OUTSIDE OF DOOR; DOOR HUNG @ 1'-0" AFF; DOOR FRAME 9'-0"H. X 3'-0" W. CASE OPENING. WELD 2 FITTING ROOM 2' - 6"1 3/4"5' - 0"HC MTL. DOOR PAINT P3 WELDED STL. (CASED OPENING) PAINT P3 PRIVACY LOCK: SCHLAGE "L" SERIES LEVER 03B TRIM, 626 FINISH; LATCHING HARDWARE L9453; HINGES: (3) 4" 450 T88; FLOOR STOP: W1276 1/2” DOME NON-RATED (3) CLOTHES HOOKS ON OUTSIDE OF DOOR; DOOR HUNG @ 1'-0" AFF; DOOR FRAME 9'-0"H. X 3'-0" W. CASE OPENING. WELD 3 FLUSH PANEL 3' - 0"1 3/4"7' - 0"HC MTL. DOOR PAINT P2 WELDED STL.PAINT P2 ENTRY LOCK: SCHLAGE "L" SERIES LEVER 03B TRIM, 626 FINISH, LATCHING HARDWARE L9453, KEYED LEVER; HINGES: (3) 4" 450 T88; FLOOR STOP: W1276 1/2” DOME NON-RATED 4 FLUSH PANEL 1' - 6"1 3/4"7' - 0"HC MTL. DOOR PAINT P2 WELDED STL.PAINT P2 ENTRY LOCK: SCHLAGE "L" SERIES LEVER 03B TRIM, 626 FINISH, LATCHING HARDWARE L9453, KEYED LEVER; HINGES: (3) 4" 450 T88; FLOOR STOP: W1276 1/2” DOME NON-RATED 1/4" = 1'-0"A102 1 FIXTURE PLAN 1/4" = 1'-0"A102 2 FLOOR FINISH PLAN 1/4" = 1'-0"A102 3 EAST ACCESSIBLE FITTING ELEVATION 1/4" = 1'-0"A102 4 NORTH ACCESSIBLE FITTING ELEVATION 1/4" = 1'-0"A102 5 NORTH FITTING ELEVATION North 0'2'4'8'16' North 0'2'4'8'16' No.Description Date Reviewed for Code Compliance Code: 2009 International Building Code (IBC) By Martin Haeberle at 11:31 am, Nov 30, 2012 EXISTING/NEW DEMISING WALL. SEE PLAN. RECESSED T-STANDARDS W/BRACKET HOLES 1" O.C. CUSTOM 83" LENGTH 1/2"x23-3/8"x83" DUROCK PANELING SHEETS PROVIDED, INSTALLED, AND CLEAR COAT FINISHED BY G.C. 4" x 20 GAUGE FLAT METAL STRAP AT EXISTING DEMISING WALL & FRAMING SPACER/SHIM 1/4" x 9/16" BLACK "U" MOLDING SUPPLIED AND INSTALLED BY TENANT EXISTING/NEW DEMISING WALL. SEE PLAN. RECESSED T-STANDARDS W/BLACK POWDERCOAT FINISH & BRACKET HOLES 1" O.C. CUSTOM 83" LENGTH (REEVE EQUIPMENT CO. #S-703-8-MB) PROVIDED AND INSTALLED BY TENANT 1/2"x23-3/8"x83" DUROCK PANELING SHEETS PROVIDED, INSTALLED, AND CLEAR COAT FINISHED BY G.C. (2) 1 5/8" X 20 GA. MTL. STUDS @ 24" O.C. BY G.C. 1' - 0"1' - 0"MINIMUM 6"2' - 0" 4" x 20 GA.FLAT METAL STRAP AT EXISTING DEMISING WALL & FRAMING @ 7' - 10 3/4", 5' - 7 3/4", 8", 3' - 4 5/8", & 1' - 1 1/2" AFF MITER @ "U" MOLDING 1/4" "U" BLACK REVEAL MOLDING SUPPLIED & INSTALLED BY TENANT FLAT HEAD SCREW & WASHER, TYP. (BLACK) RECESSED T-STANDARDS W/BLACK POWDERCOAT FINISH & BRACKET HOLES 1" O.C. CUSTOM 83" LENGTH (REEVE EQUIPMENT CO. #S-703-8-MB) PROVIDED AND INSTALLED BY TENANT 1/2"x23-3/8"x83" DUROCK PANELING SHEETS PROVIDED, INSTALLED, AND CLEAR COAT FINISHED BY G.C. 4" x 20 GA.FLAT METAL STRAP AT EXISTING DEMISING WALL & FRAMING @ 7' - 10 3/4", 5' - 7 3/4", 8", 3' - 4 5/8", & 1' - 1 1/2" AFF 12" HIGH MTL. CLAD WALL BASE B1 OVER 1/2" PLYWOOD 1/2" X 2 1/2" "L" MTL. REVEAL MOLDING 1/4" "U" BLACK REVEAL MOLDING SUPPLIED & INSTALLED BY TENANT EQ EQ EQ 3' - 4 5 / 8 " 5' - 7 3 / 4 " 7' - 1 0 3 / 4 " 1" SETBACK 1" SETBACK 1" SETBACK 1" S E T B A C K 9' - 0 " 1' - 1 1 / 2 " 1' - 0 " 1/4" "U" BLACK REVEAL MOLDING SUPPLIED & INSTALLED BY TENANT 1/2"x23-3/8"x83" DUROCK PANELING SHEETS PROVIDED, INSTALLED, AND CLEAR COAT FINISHED BY G.C. 4" x 20 GA.FLAT METAL STRAP AT EXISTING DEMISING WALL & FRAMING @ 7' - 10 3/4", 5' - 7 3/4", 8", 3' - 4 5/8", & 1' - 1 1/2" AFF 12" HIGH MTL. CLAD WALL BASE B1 OVER 1/2" PLYWOOD 1/2" X 2 1/2" "L" MTL. REVEAL MOLDING EXISTING/NEW DEMISING WALL. SEE PLAN. (2) 1 5/8" X 20 GA. MTL. STUDS @ 24" O.C. BY G.C. 5/8" GYP. BD. WITH LEVEL 4 FINISH. PAINT P2 8' - 0" AFF TOP OF DUROCK 1' - 0" AFF TOP OF BASE 1' - 0 " 1/ 2 " 83 " D U R O C K P A N E L 1/ 4 " 1' - 0 1 / 4 " 9' - 0" AFF CEILING 5/8" GYP. BD. CEILING CLG1 WITH LEVEL 4 FINISH ATTACHED TO MTL. SUSPENSION SYSTEM. PAINT P2 ED SIDE ELEVATION "D" SECTION "E" SECTION 4" 2' - 0 " 8" 8" 5" DIA. WIRING HOLE 8" 8" 8" 2' - 0 " 4" 4" 2' - 0 " 1' - 4 " 3' - 8 " 4" TR A N S A C T I O N S U R F A C E 3' - 0 " 4" 4" 5" 1' - 2 " 5" 3' - 0 " 3' - 8 " FRONT ELEVATION PLAN 3' - 0"3' - 0" 6' - 0" 2' - 1 1 7 / 8 " 2' - 4 7 / 8 " 7" ELEVATION SECTION 12" HIGH MTL. CLAD WALL BASE B1 OVER 1/2" PLYWOOD 5/8" GYP. BD. WITH LEVEL 4 FINISH. PAINT P2 36" x65" MTL. MIRROR FRAME & WOOD BACKING PROVIDED & INSTALLED BY TENANT SCREW WOOD BACKING INTO FRAMING 1/4" x35"x56" MIRROR W/POLISHED EDGES BY G.C. 36" x65" MTL. MIRROR FRAME & WOOD BACKING PROVIDED & INSTALLED BY TENANT 1/4" x35"x56" MIRROR W/POLISHED EDGES BY G.C. SCREW WOOD BACKING INTO FRAMING 36" x65" MTL. MIRROR FRAME & WOOD BACKING PROVIDED & INSTALLED BY TENANT (2) SCREWS Scale Project Number Date Drawn by Checked by On e W i l l o w B r i d g e R o a d , U n i t C - 3 Ea s t M e a d o w D r i v e , V a i l , C o l o r a d o 8 1 6 5 7 As indicated 11 / 2 1 / 2 0 1 2 1 2 : 1 3 : 1 3 P M A103 DETAILS 20112 VAIL OWB OAKLEY SSV 21 November 2012 PT PT 3/4" = 1'-0"A103 1 DISPLAY WALL PLAN 3" = 1'-0"A103 2 DISPLAY WALL PLAN DETAIL 3/8" = 1'-0"A103 3 DISPLAY WALL ELEVATION 1 1/2" = 1'-0"A103 4 DISPLAY WALL SECTION 3/4" = 1'-0"A103 5 CASHWRAP 1/2" = 1'-0"A103 6 FITTTING ROOM MIRROR No.Description Date Reviewed for Code Compliance Code: 2009 International Building Code (IBC) By Martin Haeberle at 11:31 am, Nov 30, 2012 Re v i e w e d f o r C o d e C o m p l i a n c e Co d e : 2 0 0 9 I n t e r n a t i o n a l B u i l d i n g C o d e ( I B C ) By Ma r t i n Ha e b e r l e at 11 : 3 1 am , No v 30 , 20 1 2 ELECTRICAL SPECIFICATIONS GENERAL REQUIREMENTS DRAWINGS ARE DIAGRAMMATIC AND DO NOT INDICATE ALL FITTINGS, JUNCTION BOXES, ETC. REQUIRED. PROVIDE ALL REQUIRED EQUIPMENT, CONDUIT, FITTINGS, WIRING, BOXES, ETC. FOR A COMPLETE AND OPERATIONAL INSTALLATION. WORK AND EQUIPMENT SHALL COMPLY WITH STATE AND LOCALLY ADOPTED CODES AND STANDARDS, INCLUDING THE NATIONAL ELECTRICAL CODE (NEC), INTERNATIONAL CODES (I-CODES), AND LOCAL AMENDMENTS. ANYTHING DRAWN OR SPECIFIED SHALL NOT BE CONSTRUED TO CONFLICT WITH STATE AND LOCALLY ADOPTED CODES AND STANDARDS, INCLUDING THE NATIONAL ELECTRICAL CODE, WHICH GOVERNS THE INSTALLATION OF ANY ELECTRICAL WORK. ITEMS SHALL NOT BE INSTALLED IN CONFLICT WITH THE NEC. RESOLVE ANY AND ALL CONFLICTS PRIOR TO INSTALLATION. BECOME THOROUGHLY ACQUAINTED WITH THE CONDITIONS UNDER WHICH WORK IS TO BE PERFORMED. EXAMINE ALL SERVICES, EQUIPMENT, AND EXISTING CONDITIONS, WHICH THIS WORK IS IN ANY WAY DEPENDENT UPON, AND BRING ANY DISCREPANCIES OR OMISSIONS FOUND IN THE DRAWINGS TO THE ELECTRICAL ENGINEER'S ATTENTION PRIOR TO SUBMITTING BID. THE LOCATION OF OUTLETS AND EQUIPMENT SHOWN ON THE DRAWINGS ARE APPROXIMATE. THE ARCHITECT AND ENGINEER SHALL HAVE THE RIGHT TO ADJUST THE LOCATION OF OUTLETS OR FIXTURES, WITHIN 10' OF THE SPECIFIED LOCATION, BEFORE THEY ARE INSTALLED AND WITHOUT ADDITIONAL COST. PROVIDE DRAWINGS TO LOCAL BUILDING AUTHORITY AND OBTAIN A PERMIT PRIOR TO STARTING ANY WORK. NOTIFY ELECTRICAL ENGINEER OF ANY CHANGES REQUESTED BY THE LOCAL BUILDING AUTHORITY IMMEDIATELY AND PRIOR TO STARTING WORK. VERIFY AND COMPLY WITH UTILITY COMPANY REQUIREMENTS. PROVIDE METERING, CONNECTION CABINETS, CT CABINETS, AND TRANSFORMER AND CONNECTION CABINET PADS PER LOCAL UTILITY COMPANY REQUIREMENTS. PROVIDE A REDLINED AS-BUILT SET OF ELECTRICAL DRAWINGS TO OWNER UPON COMPLETION OF WORK. ELECTRICAL WORK SHOWN LIGHT OR MARKED "E" IS EXISTING, SHOWN DARK IS NEW, AND SHOWN DASHED IS EXISTING TO BE REMOVED OR RELOCATED UNLESS OTHERWISE INDICATED. DASHING MAY ALSO INDICATE UNDER FLOOR OR UNDER GROUND CONDUIT. IF UNCLEAR, CONTACT ELECTRICAL ENGINEER FOR CLARIFICATION. EQUIPMENT, WIRING, AND DEVICES SHOWN ARE NEW UNLESS OTHERWISE NOTED. MAINTAIN CIRCUITING TO EXISTING EQUIPMENT AND DEVICES TO REMAIN. REFERENCE ARCHITECTURAL DRAWINGS FOR ADDITIONAL INFORMATION. INSTALL EQUIPMENT AND DEVICES PER THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. NOTIFY ELECTRICAL ENGINEER, PRIOR TO INSTALLING EQUIPMENT AND DEVICES, IF MANUFACTURER'S INSTALLATION INSTRUCTIONS CONFLICT WITH ELECTRICAL INFORMATION ON THE THESE DRAWINGS. ELECTRICALLY OPERATED EQUIPMENT SHOWN ON PLANS, AND NOT CIRCUITED ON THE ELECTRICAL PLANS, WILL REQUIRE ELECTRICAL SERVICE. CONTACT ELECTRICAL ENGINEER FOR CONNECTION REQUIREMENTS AND CLARIFICATION PRIOR TO BID. THE COST FOR THIS WORK SHALL BE INCLUDED IN THE BID. PROVIDE HANGERS AND SUPPORTS TO ADEQUATELY AND SECURELY SUPPORT ELECTRICAL SYSTEM COMPONENTS IN A NEAT AND WORKMANLIKE MANNER. MAINTAIN THE FIRE RATING OF THE ASSEMBLY (CEILING, WALL, OR FLOOR) IN WHICH EQUIPMENT, WIRING, AND DEVICES ARE TO BE INSTALLED. SUBMITTALS AND SUBSTITUTIONS PROVIDE PRODUCT DATA SHEETS AND SHOP DRAWINGS FOR EQUIPMENT, FIXTURES, AND DEVICES TO ELECTRICAL ENGINEER PRIOR TO PURCHASING. REVIEW, STAMP AND INITIAL ALL ELECTRICAL SUBMITTALS AND SHOP DRAWINGS CERTIFYING THAT THE SUBMITTALS HAVE BEEN REVIEWED PRIOR TO SUBMITTING TO ELECTRICAL ENGINEER FOR REVIEW. EQUIPMENT AND FIXTURES SPECIFIED REPRESENT REQUIRED QUALITY AND PERFORMANCE. PROVIDE PRODUCT DATA SHEETS AND SHOP DRAWING OF PROPOSED SUBSTITUTIONS TO SPECIFIED EQUIPMENT TO ELECTRICAL ENGINEER FOR REVIEW. ELECTRICAL ENGINEER SHALL DETERMINE THE ACCEPTABILITY OF SUBSTITUTIONS TO SPECIFIED EQUIPMENT. REVIEW, STAMP AND INITIALED ALL ELECTRICAL SUBMITTALS AND SHOP DRAWINGS CERTIFYING THAT SUBMITTALS HAVE BEEN REVIEWED PRIOR TO SUBMITTING TO ELECTRICAL ENGINEER FOR REVIEW. SUBMITTALS AND SHOP DRAWINGS ARE TO INCLUDE THE FOLLOWING: KEY TO PLAN DESIGNATIONS, MANUFACTURER, MODEL NUMBER, DATA SHEETS, QUANTITIES, COLORS, LABELS, DIMENSIONS, INSTALLATION INSTRUCTIONS, AND ANY ADDITIONAL INFORMATION REQUIRED TO DETERMINE IF THE PRODUCT MEETS THE DESIGN INTENT. CONSTRUCTION PHASE REVIEW REQUIREMENTS INSTALL POWER, LIGHTING, COMMUNICATIONS AND SPECIAL SYSTEM (FIRE ALARM, SECURITY, BUILDING AUTOMATION, ETC) BOXES PRIOR TO RUNNING CABLE OR CONDUIT TO BOXES. ARRANGE FOR OWNER, ARCHITECT, AND ENGINEER TO REVIEW BOX LOCATIONS PRIOR TO RUNNING CABLE OR CONDUIT TO BOXES. ADJUST BOXES AS DIRECTED BY OWNER, ARCHITECT, AND ENGINEER. REQUESTS FOR MODIFICATIONS TO THE CONTRACT (CHANGE ORDERS) REQUESTS BY CONTRACTOR FOR ADDITION OR REDUCTION TO THE CONTRACT AMOUNT SHALL BE ACCOMPANIED BY THE FOLLOWING FOR EVALUATION BY THE OWNER AND ENGINEER: 1.ORIGIN AND DATE OF CLAIM 2.QUANTITIES OF PRODUCTS, LABOR, AND EQUIPMENT 3.DOLLAR AMOUNT OF TAXES, OVERHEAD, AND PROFIT 4.JUSTIFICATION FOR ANY CHANGE IN CONTRACT TIME 5.CREDIT AMOUNT FOR DELETIONS (WITH DOCUMENTATION) 6.DATES AND TIMES OF WORK PERFORMED, AND BY WHOM 7.TIME RECORDS AND WAGE RATES PAID 8.INVOICES AND RECEIPTS FOR PRODUCTS AND EQUIPMENT SUBMIT ALL DOCUMENTATION TO ENGINEER AND OWNER, AND OBTAIN WRITTEN APPROVAL PRIOR TO STARTING ANY WORK THAT AFFECTS THE CONTRACT AMOUNT OR COMPLETION DATE. EXISTING CONDITIONS THESE DRAWINGS CONTAIN INFORMATION REGARDING EXISTING CONDITIONS. THIS INFORMATION WAS COMPILED FROM EXISTING DRAWINGS OR CASUAL FIELD OBSERVATIONS. IN SOME CASES, ASSUMPTIONS WERE MADE WHEN FIELD OBSERVATIONS OR EXISTING DRAWINGS DID NOT PROVIDE NECESSARY INFORMATION (I.E. LOCKED DISCONNECTS, NO WIRE SIZE INDICATED, NAMEPLATE DATA MISSING, INACCURATE AS-BUILT DRAWINGS, ETC.). EXISTING CONDITIONS SHALL BE VERIFIED AND ALLOWED FOR PRIOR TO BID AND CONSTRUCTION. NOTIFY THE ELECTRICAL ENGINEER OF ANY DISCREPANCIES WITH THESE DRAWINGS IMMEDIATELY AND PRIOR TO COMMENCING ANY FURTHER WORK. COORDINATION THE ELECTRICAL DRAWINGS ARE ONLY ONE PART OF A COMPLETE SET OF CONSTRUCTION DOCUMENTS. EXAMINE THE ARCHITECTURAL, MECHANICAL, AND PLUMBING DRAWINGS PRIOR SUBMITTING BID AND STARTING WORK TO DETERMINE THE FULL EXTENT OF ELECTRICAL WORK REQUIRED. COORDINATE WORK WITH OTHER TRADES PRIOR TO ROUGH-IN. COORDINATION SHALL INCLUDE REVIEWING THE ARCHITECTURAL, MECHANICAL, PLUMBING, ETC. DRAWINGS AND SHOP DRAWINGS PRIOR TO BID AND CONSTRUCTION. OBTAIN AND REVIEW SHOP DRAWINGS, PRODUCT DATA, MANUFACTURER'S WIRING DIAGRAMS AND MANUFACTURER'S INSTRUCTIONS FOR EQUIPMENT PROVIDED BY OTHERS. THE FINAL LOCATION OF EQUIPMENT SHALL BE COORDINATED IN THE FIELD, PRIOR TO ROUGH-IN, TO MEET APPLICABLE LOCATION, HEIGHT AND CLEARANCE REQUIREMENTS. MAINTAINING EXISTING SERVICES MAINTAIN THE ELECTRICAL SERVICE TO EXISTING TENANTS AND AREAS. ANY SERVICE DISCONTINUITY SHALL BE COORDINATED AND APPROVED BY OWNER AND TENANTS PRIOR TO OUTAGE. IF REQUIRED, PROVIDE TEMPORARY POWER DURING OUTAGE. WIRING AND CONDUIT NEW WIRING SHALL BE THHN/THWNƒ&,NSULATED COPPER UNLESS OTHERWISE NOTED. ALUMINUM CONDUCTORS SHALL BE XHHW-2, INSULATED COMPACT STRAND. THE CONDUCTORS FOR 15A AND 20A BRANCH CIRCUITS SHALL BE #12 THHN/THWN-2, ƒ& INSULATED COPPER. BRANCH-CIRCUIT CONDUCTORS GREATER THAN 20A SHALL BE AS INDICATED ON PLANS OR REQUIRED PER CODE. 20 AMPERE BRANCH CIRCUIT HOMERUNS OVER 75' SHALL BE #10AWG CU AND OVER 150' SHALL BE #8AWG CU. 7+(0$;,080180%(52)&21'8&7256,1$&21'8,7)25$‘6<67(06+$//%(7+5(( $‘ %‘&‘ 127,1&/8',1*1(875$/$1'(48,30(17*5281',1*&21'8&725681/(66 OTHERWISE INDICATED. CONDUIT SIZE SHALL BE BASED UPON NEC CHAPTER 9 AND ANNEX C. MORE THAN 3 CURRENT-CARRYING CONDUCTORS MAY BE INSTALLED IN A RACEWAY IF THE APPROPRIATE AMPACITY-DERATING FACTORS ARE APPLIED. PROVIDE A DEDICATED NEUTRAL FOR EACH LINE-TO-NEUTRAL CIRCUIT UNLESS A MULTI-POLE BREAKER, WHICH DISCONNECTS ALL PHASE CONDUCTORS THAT SHARE A NEUTRAL, IS PROVIDED (LISTED BREAKER-TIES ARE PERMITTED). PROVIDE AN INSULATED EQUIPMENT GROUNDING CONDUCTOR WITH ALL FEEDERS AND BRANCH-CIRCUIT WIRING. INCREASE CONDUIT SIZE AS REQUIRED TO ACCOMMODATE EQUIPMENT GROUNDING CONDUCTOR. CONDUIT SHALL BE CONCEALED IN WALLS, FLOOR OR CEILING IN FINISHED AREAS UNLESS OTHERWISE INDICATED. IN FINISHED AREAS, WHERE CONDUIT AND CABLE CAN NOT BE CONCEALED IN WALLS OR CEILINGS (I.E. EXISTING MASONRY CONSTRUCTION), PROVIDE WIREMOLD OR EQUAL SURFACE MOUNTED RACEWAY AS APPROVED BY ARCHITECT OR ENGINEER. THE TYPE OF CONDUIT SHALL BE AS FOLLOWS FOR ALL FEEDERS AND BRANCH CIRCUITS, UNLESS OTHERWISE SPECIFIED OR REQUIRED. REFERENCE THE NEC FOR ADDITIONAL APPLICATION REQUIREMENTS. APPLICATION TYPE OF CONDUIT IN CONCRETE OR MASONRY EMT, GRC OR PVC OUTDOORS (ABOVE GRADE)EMT OR GRC BRANCH CIRCUITS (EXPOSED) EMT OR GRC INTERIOR BRANCH CIRCUITS (CONCEALED BEHIND DRYWALL)MC CABLE OR EMT INTERIOR BRANCH CIRCUITS (ABOVE DROPPED CEILINGS)EMT SUPPLY TO DISTRIBUTION PANELS EMT OR GRC UNDERGROUND PVC SCHED. 40 OR 80 AS REQ'D FINAL CONNECTIONS TO LIGHT FIXTURES SHALL BE MADE WITH FLEXIBLE METAL CONDUIT WITH A MAXIMUM LENGTH OF 6'. FINAL CONNECTIONS TO MECHANICAL OR VIBRATING EQUIPMENT, SUCH AS MOTORS AND TRANSFORMERS, SHALL BE MADE WITH FLEXIBLE METAL CONDUIT. INSTALL CONDUIT EXPOSED TO SUNLIGHT ON ROOFTOPS A MINIMUM OF 12" ABOVE ROOF SURFACE. PROVIDE PVC COATED GRC FOR ELBOWS IN PVC CONDUIT RUNS. ALL CONDUITS AND CABLES PASSING THROUGH RATED WALLS, FLOORS OR CEILINGS SHALL BE FIRE STOPPED WITH APPROVED FIRE BARRIER CAULK. INSTALL CAULK PER MANUFACTURE'S INSTRUCTIONS AND MAINTAIN THE RATING OF THE WALL, FLOOR, OR CEILING BEING PENETRATED. DEVICES DEVICE AND FACEPLATE COLOR SHALL BE AS SPECIFIED BY THE ARCHITECT OR TO MATCH EXISTING. COORDINATE FACEPLATE AND DEVICE COLORS WITH ARCHITECT, INTERIOR DESIGNER AND OWNER PRIOR TO PURCHASING AND INSTALLING DEVICES AND FACEPLATES. PROVIDE COMMERCIAL SPECIFICATION GRADE SWITCHES AND RECEPTACLES. PROVIDE DEVICES AS INDICATED BELOW: DEVICE MANUFACTURER MODEL NUMBER WALL OCCUPANCY SENSOR WATT STOPPER DW-100 INCANDESCENT DIMMER LUTRON NOVA SERIES FLUORESCENT DIMMER LUTRON NOVA SERIES PROVIDE GFI PROTECTION FOR 120V, 15A AND 20A RECEPTACLES INSTALLED IN THE FOLLOWING NON-DWELLING LOCATIONS: BATHROOMS, KITCHENS, ROOFTOPS, OUTDOORS, SINKS (WITHIN 6' OF OUTSIDE EDGE OF SINK), FEEDING ELECTRIC WATER COOLERS, AND LOCATIONS INDICATED ON POWER PLAN. PROVIDE GFI RECEPTACLE, FACELESS GFI DEVICE FEEDING STANDARD RECEPTACLE, OR GFI CIRCUIT-BREAKER. THE GROUND-FAULT CIRCUIT-INTERRUPTER SHALL BE INSTALLED IN A READILY ACCESSIBLE LOCATION. PROVIDE WEATHER-RESISTANT RECEPTACLES FOR RECEPTACLES INSTALLED IN DAMP OR WET LOCATIONS. PROVIDE HUBBELL RECEPTACLES WITH THE APPROPRIATE NEMA CONFIGURATION FOR RECEPTACLES SHOWN ON THE ELECTRICAL PLAN. PROVIDE 6' CORD AND PLUG FOR SPECIAL-PURPOSE RECEPTACLES IF EQUIPMENT TO BE INSTALLED IS NOT SUPPLIED WITH A CORD AND PLUG. PROVIDE FLOOR-MOUNTED DEVICE COVERS MOUNTED FLUSH WITH THE FINISHED FLOOR SURFACE. PROVIDE WIRING DEVICES AS MANUFACTURED BY HUBBELL, PASS AND SEYMOUR, LEVITION, WATT-STOPPER, LUTRON OR EQUAL. COORDINATE MOUNTING HEIGHTS OF SWITCHES, RECEPTACLES, PHONE OUTLETS, DATA OUTLETS, TV OUTLETS, AND LIGHT FIXTURES WITH ARCHITECTURAL DRAWINGS. THE MOUNTING HEIGHT FOR DEVICES SHALL BE AS INDICATED BELOW, UNLESS OTHERWISE NOTED. MOUNTING HEIGHTS ARE TO CENTER OF DEVICE, UNLESS OTHERWISE NOTED. MATCH MOUNTING HEIGHT OF EXISTING DEVICES IF APPLICABLE. GENERAL RECEPTACLES (COMMERCIAL) @18" AFF ABOVE COUNTER RECEPTACLES AND SWITCHES @ 2" ABOVE COUNTER OR BACKSPLASH TO BOTTOM OF DEVICE (COORDINATE WITH ARCHITECT) LIGHT SWITCHES @ 44" AFF LIGHT SWITCHES IN BATHROOMS @ 44" AFF TELEPHONE OUTLETS @ 18" AFF TELEPHONE OUTLET (WALL MOUNTED) 44" AFF CLOCK OUTLETS @ 7'-6" AFF TV OUTLETS (COMMERCIAL) @ 18" AFF DATA/PHONE OUTLETS (COMMERCIAL) @ 18" AFF PROVIDE "IN-USE" WEATHERPROOF COVER FOR EXTERIOR RECEPTACLES. COMPLY WITH ADA STANDARDS FOR MOUNTING HEIGHTS AND LOCATIONS. DEVICES IN THE SAME LOCATION AND AT THE SAME MOUNTING HEIGHT SHALL BE MOUNTED UNDER A COMMON WALL PLATE. DISTRIBUTION EQUIPMENT PROVIDE DISTRIBUTION PANELS, DISCONNECTS, CONTACTORS, ETC. OF VOLTAGE, AMPERAGE, PHASE, AND SHORT-CIRCUIT RATINGS AS INDICATED ON PLANS. 7(50,1$7,2166+$//%(5$7('ƒ&0,1,080&8$/ FUSES SPECIFIED ARE AS MANUFACTURED BY BUSSMANN. THE SAME CLASS OF FUSE AS MANUFACTURED BY LITTELFUSE AND GOULD-SHAWMUT MAY BE SUBSTITUTED. ENCLOSURES FOR EQUIPMENT AND DEVICES SHALL BE SUITABLE FOR THE INSTALLED LOCATION. PROVIDE A LISTED BREAKER-TIE OR MULTI-POLE BREAKER FOR EACH MULTIWIRE (SHARED NEUTRAL) BRANCH CIRCUIT. PROVIDE DISTRIBUTION EQUIPMENT AS MANUFACTURED BY AMERICAN MIDWEST POWER, SQUARE D, ELECTRO-MECHANICAL INDUSTRIES, CUTLER-HAMMER, SIEMENS, ERICKSON ELECTRIC, GE OR METRON. THE MOUNTING HEIGHT FOR DISTRIBUTION EQUIPMENT SHALL BE AS INDICATED BELOW, UNLESS OTHERWISE NOTED. PANELS/LOADCENTERS - 6' AFF MAX TO CENTER OF TOP HANDLE DISCONNECT SWITCHES - 6'-6" AFF MAX TO CENTER OF HANDLE METER CENTER - 3' MIN, 6' MAX TO CENTER OF METERS PROVIDE BRASS TAG (ATTACHED WITH BRASS SCREWS), INDICATING UNIT SERVED ON SERVICE DISCONNECTS, FEEDER DISCONNECTS, AND METERS SERVING MULTI-TENANT FACILITIES. PROVIDE A TYPED PANEL SCHEDULE WITH LOAD DESCRIPTIONS FOR PANELS AFFECTED BY THIS PROJECT. PROVIDE A PHENOLIC LABEL ON EACH NEW OR RENAMED PANEL INDICATING THE PANEL NAME. IDENTIFICATION FOR ELECTRICAL SYSTEMS PROVIDE IDENTIFICATION LABELS OR HANDWRITTEN TEXT USING INDELIBLE MARKER TO IDENTIFY CIRCUITS ENCLOSED IN BOXES. USE IDENTIFICATION LABEL OR ENGRAVED FACEPLATE TO IDENTIFY BRANCH CIRCUITS FEEDING RECEPTACLES AND SWITCHES. PROVIDE IDENTIFICATION ON INSIDE SURFACE OF FACEPLATE FOR RECEPTACLES AND SWITCHES IN PUBLIC AREAS OR IN AREAS AS DIRECTED BY ARCHITECT OR OWNER. USE IDENTIFICATION LABEL TO IDENTIFY RECEPTACLES PROTECTED BY UPSTREAM GFI PROTECTION. LABEL CONDUCTORS AND CABLE WITH POWER SOURCE AND CIRCUIT NUMBER OR OTHER REQUIRED DESIGNATION. USE WRAP-AROUND SELF-ADHESIVE VINYL CLOTH, WRAP-AROUND SELF-ADHESIVE VINYL SELF-LAMINATING, HEAT-SHRINK SLEEVE, PLASTIC SLEEVE, PLASTIC CLIP-ON, OR VINYL SPLIT SLEEVE TYPE MARKERS SUITABLE FOR THE CONDUCTOR OR CABLE TO BE IDENTIFIED. USE FACTORY PRE-PRINTED OR MACHINE-PRINTED TEXT, ALL CAPITALIZED UNLESS OTHERWISE INDICATED. IDENTIFY EACH PIECE OF ELECTRICAL EQUIPMENT WITH AN IDENTIFICATION NAMEPLATE. PROVIDE THE FOLLOWING INFORMATION ON THE NAMEPLATE: SWITCHBOARDS: AMPERE RATING, VOLTAGE AND PHASE, POWER SOURCE AND CIRCUIT NUMBER, LOADS BEING SERVED. PANELBOARDS AND LOAD CENTERS: AMPERE RATING, VOLTAGE AND PHASE, POWER SOURCE AND CIRCUIT NUMBER, LOADS BEING SERVED (TYPED CIRCUIT DIRECTORY). ENCLOSED SWITCHES AND CIRCUIT BREAKERS: AMPERE RATING, VOLTAGE AND PHASE, POWER SOURCE AND CIRCUIT NUMBER, LOAD BEING SERVED. CONDUCTOR INSULATION SHALL BE COLOR CODED AS FOLLOWS: 9‘3+$6($%/$&.3+$6(%5('3+$6(&%/8( IDENTIFY EXISTING ELEMENTS TO REMAIN THAT ARE NOT ALREADY IDENTIFIED. PROVIDE TYPEWRITTEN CIRCUIT DIRECTORY TO IDENTIFY LOADS SERVED FOR PANELBOARDS AND LOAD CENTERS. MECHANICAL EQUIPMENT REFERENCE MECHANICAL DRAWINGS FOR EXACT LOCATION AND REQUIREMENTS OF MECHANICAL EQUIPMENT. ELECTRICALLY OPERATED EQUIPMENT SHOWN ON THE MECHANICAL PLANS AND NOT SHOWN ON THE ELECTRICAL PLANS WILL REQUIRE ELECTRICAL SERVICE. CONTACT ELECTRICAL ENGINEER FOR CONNECTION REQUIREMENTS PRIOR TO BID. THE COST FOR THIS WORK SHALL BE INCLUDED IN THE BID. VERIFY MECHANICAL EQUIPMENT NAMEPLATE DATA (VOLTAGE, PHASE, FLA, MCA, MOCP, ETC.) PRIOR TO ROUGH-IN. NOTIFY ELECTRICAL ENGINEER IN WRITING OF ANY DISCREPANCIES WITH THESE DRAWINGS IMMEDIATELY AND PRIOR TO COMMENCING ANY FURTHER WORK. MECHANICAL CONTRACTOR SHALL PROVIDE STARTERS FOR MECHANICAL EQUIPMENT. MECHANICAL CONTRACTOR SHALL PROVIDE CONDUIT, WIRE, AND DEVICES FOR MECHANICAL EQUIPMENT CONTROLS, UNLESS OTHERWISE INDICATED ON THE ELECTRICAL DRAWINGS. ELECTRICAL CONTRACTOR SHALL PROVIDE MECHANICAL EQUIPMENT CONTROL WIRING, CONDUIT, AND DEVICES IF INDICATED ON THE ELECTRICAL DRAWINGS. NOTIFY ELECTRICAL ENGINEER IN WRITING OF ANY DISCREPANCIES WITH THESE DRAWINGS IMMEDIATELY AND PRIOR TO COMMENCING ANY FURTHER WORK. REFERENCE MECHANICAL DRAWINGS FOR LOCATIONS OF FIRE SMOKE DAMPERS AND CONTROL REQUIREMENTS OF MECHANICAL EQUIPMENT. PROVIDE 120V TO FIRE SMOKE DAMPERS AND PROVIDE EITHER DUCT OR SMOKE DETECTORS AS REQUIRED. RETURN AIR SYSTEMS OVER 2000CFM REQUIRE A SMOKE DETECTOR TO SHUT UNIT OFF MECHANICAL EQUIPMENT UPON ACTIVATION OF SMOKE DETECTOR. CONNECT DETECTORS TO FIRE ALARM SYSTEM IF APPLICABLE. TELEPHONE, DATA, AND CABLE OUTLETS PROVIDE A 4"X4" JUNCTION BOX WITH SINGLE-GANG PLASTER RING AND A 3/4" CONDUIT WITH PULL STRING TO NEAREST ACCESSIBLE CEILING SPACE FOR EACH WALL MOUNTED PHONE, DATA, AND CABLE OUTLET. PROVIDE A FLUSH FLOOR BOX WITH FLUSH FACE PLATE AND A 3/4" CONDUIT WITH PULL STRING TO NEAREST ACCESSIBLE CEILING SPACE FOR EACH FLOOR MOUNTED PHONE, DATA, AND CABLE OUTLET. LIGHTING PROVIDE LIGHT FIXTURES AS INDICATED ON LIGHTING PLAN OR FIXTURE SCHEDULE. THE MOUNTING HEIGHT FOR LIGHT FIXTURES SHALL BE AS INDICATED ON THE FIXTURE SCHEDULE, ARCHITECTURAL ELEVATIONS, OR AS SHOWN BELOW, UNLESS OTHERWISE NOTED. MATCH MOUNTING HEIGHT OF EXISTING LIGHT FIXTURES IF APPLICABLE. INSTALL EXIT AND EMERGENCY LIGHTS @ 6" BELOW CEILING TO TOP OF FIXTURE WITH A MAXIMUM MOUNTING HEIGHT OF 10' AFF. PROVIDE A DEDICATED NEUTRAL CONDUCTOR FOR EACH LIGHTING CIRCUIT. CONNECT EXIT AND EMERGENCY LIGHTING TO NON-SWITCHED LEG OF LOCAL LIGHTING CIRCUIT UNLESS OTHERWISE NOTED. MAKE CONNECTIONS TO LIGHT FIXTURES USING BUILDING WIRE WITH INSULATION SUITABLE FOR TEMPERATURE CONDITIONS WITHIN THE LUMINAIRE. PROVIDE ONE SAMPLE OF EACH LIGHT FIXTURE FOR REVIEW BY THE ARCHITECT, ELECTRICAL ENGINEER, AND OWNER OR OWNER'S REPRESENTATIVE PRIOR TO ORDERING THE LIGHT FIXTURES. MAINTAIN THE FIRE RATING OF THE ASSEMBLY (CEILING OR WALL) IN WHICH LIGHT FIXTURES ARE TO BE INSTALLED. PROVIDE FIRE-RATED FIXTURES OR PROVIDE BOX AROUND FIXTURES AS MANUFACTURED BY TENMAT, EZ BARRIER OR EQUAL. PROVIDE 30A LIGHTING CONTACTOR WITH NUMBER OF POLES AS REQUIRED FOR LIGHTING CONTROLLED BY A TIME SWITCH OR PHOTOCELL. TIME SWITCH: TORK EWZ201 TIME SWITCH WITH PHOTOCELL: TORK DGLC SERIES TELEPHONE SERVICE PROVIDE 1" CONDUIT FROM BUILDING TELEPHONE TERMINAL BOARD TO TELEPHONE BOARD IN TENANT'S SPACE. COORDINATE EXACT LOCATION WITH TENANT PRIOR TO ROUGH-IN. PROVIDE #6 GROUND FROM BUILDING GROUNDING ELECTRODE SYSTEM TO TELEPHONE BACKBOARD. PROVIDE GROUND BAR AT PHONE BOARD. FIRE/SPRINKLER ALARM AND DETECTION SYSTEM ALARM AND DETECTION SYSTEM SHALL BE DESIGN/BUILD. PROVIDE ALL COMPONENTS NECESSARY FOR A COMPLETE AND OPERATIONAL SYSTEM, REGARDLESS OF WHETHER SHOWN IN THE CONTRACT DOCUMENTS OR NOT. ALARM AND DETECTION SYSTEM SHOP DRAWINGS SHALL BE PREPARED BY THE SYSTEM SUPPLIER AND SIGNED AND SEALED BY A COLORADO LICENSED PROFESSIONAL ENGINEER. SHOP DRAWINGS SHALL INCLUDE DEVICE LOCATIONS, WIRING DIAGRAM, EQUIPMENT SPECIFICATIONS, BATTERY CALCULATIONS, VOLTAGE DROP CALCULATIONS, SEQUENCE OF OPERATION AND OTHER DETAILS REQUIRED BY THE LOCAL BUILDING DEPARTMENT, IFC AND NFPA 72 WITH LOCAL AMENDMENTS. THE SYSTEM SHALL BE DESIGNED IN ACCORDANCE WITH THE REQUIREMENTS OF THE IBC, IFC, NFPA 72 AND LOCAL CODES AND ORDINANCES. SHOP DRAWINGS SHALL BE SUBMITTED TO THE BUILDING DEPARTMENT AND FIRE DEPARTMENT AS A DEFERRED SUBMITTAL. SHOP DRAWINGS SHALL BE APPROVED PRIOR TO PURCHASING ANY EQUIPMENT OR STARTING ANY WORK. BRANCH-CIRCUIT WIRING SCHEDULE (UNLESS OTHERWISE NOTED) 15 A #12 AWG #12 AWG #12 AWG 1/2" 20 A #12 AWG #12 AWG #12 AWG 1/2" 25 A #10 AWG #10 AWG #10 AWG 1/2" 30 A #10 AWG #10 AWG #10 AWG 1/2" 35 A #8 AWG #8 AWG #10 AWG 3/4" 40 A #8 AWG #8 AWG #10 AWG 3/4" 45 A #6 AWG #6 AWG #10 AWG 1" 50 A #6 AWG #6 AWG #10 AWG 1" 60 A #4 AWG #4 AWG #10 AWG 1 1/4" 70 A #4 AWG #4 AWG #8 AWG 1 1/4" 80 A #3 AWG #3 AWG #8 AWG 1 1/4" 90 A #2 AWG #2 AWG #8 AWG 1 1/2" 100 A #1 AWG #1 AWG #8 AWG 1 1/2" NOTES: 1.FOR MOTOR LOADS, USE MCA (MINIMUM CIRCUIT AMPACITY) TO SIZE PHASE AND NEUTRAL CONDUCTORS AND USE MOCP (MAXIMUM OVER-CURRENT PROTECTIVE DEVICE) TO SIZE EQUIPMENT GROUNDING CONDUCTOR. 2.INCREASE PHASE, NEUTRAL, AND EQUIPMENT GROUNDING CONDUCTOR SIZES BY 1 STANDARD CONDUCTOR SIZE PER EACH 75' OF CONDUCTOR LENGTH. INCREASE CONDUIT SIZE ACCORDINGLY. A A PROVIDE CLEAR SPACE EQUAL TO THE WIDTH OF EQUIPMENT OR 30", WHICHEVER IS GREATER. B PROVIDE THE FOLLOWING CLEAR SPACE IN FRONT OF EQUIPMENT: 3' FOR 0-150 L-G VOLTAGE AND 4' FOR 151-600 L-G VOLTAGE. C PROVIDE CLEAR SPACE, FOR THE WIDTH OF THE EQUIPMENT, FROM GRADE, FLOOR OR PLATFORM TO A HEIGHT OF 6-1/2' OR THE HEIGHT OF THE EQUIPMENT, WHICHEVER IS GREATER. D THE SPACE EQUAL TO THE WIDTH AND DEPTH OF THE EQUIPMENT AND EXTENDING FROM THE FLOOR TO A HEIGHT OF 6' ABOVE THE EQUIPMENT OR TO THE STRUCTURAL CEILING, WHICHEVER IS LOWER, SHALL BE DEDICATED TO THE ELECTRICAL INSTALLATION - NO PIPING, DUCTS, LEAK PROTECTION APPARATUS, OR OTHER EQUIPMENT FOREIGN TO THE ELECTRICAL INSTALLATION SHALL BE LOCATED IN THIS ZONE. SUSPENDED CEILINGS WITH REMOVABLE PANELS SHALL BE PERMITTED WITHIN THE 6' ZONE. SPRINKLER PROTECTION SHALL BE PERMITTED FOR THE DEDICATED SPACE WHERE THE PIPING COMPLIES WITH THIS SECTION. A DROPPED, SUSPENDED, OR SIMILAR CEILING THAT DOES NOT ADD STRENGTH TO THE BUILDING STRUCTURE SHALL NOT BE CONSIDERED A STRUCTURAL CEILING. E THE AREA ABOVE THE DEDICATED SPACE SHALL BE PERMITTED TO CONTAIN FOREIGN SYSTEMS, PROVIDED PROTECTION IS INSTALLED TO AVOID DAMAGE TO THE ELECTRICAL EQUIPMENT FROM CONDENSATION, LEAKS, OR BREAKS IN SUCH FOREIGN SYSTEMS. B C D D E E CLEAR SPACE/WORKING SPACE ABOUT ELECTRICAL EQUIPMENT THE FINAL LOCATION OF EQUIPMENT SHALL BE COORDINATED IN THE FIELD, PRIOR TO ROUGH-IN, TO MEET APPLICABLE LOCATION, HEIGHT AND CLEARANCE REQUIREMENTS. THE ELECTRICAL CONTRACTOR SHALL STOP WORK IMMEDIATELY, AND ADVISE OTHERS TO STOP WORK IF THERE IS A CONFLICT WITH THE ELECTRICAL CLEARANCE AND WORK SPACE REQUIREMENTS PER THE ABOVE INFORMATION AND THE NEC. D FRONT VIEW OF EQUIPMENT SIDE VIEW OF EQUIPMENT M VC S S M Scale Project Number Date Drawn by Checked by On e W i l l o w B r i d g e C o m m e r c i a l , R e t a i l 2 Ea s t M e a d o w D r i v e , V a i l , C o l o r a d o 8 1 6 5 7 AS NOTED E0019364 Teddy Lane Suite 101, Lone Tree, CO 80124-2873 Project Number: Village Square at Lone Tree (720) 489-1609 Fax (720) 489-1611 2012C Est. 1984 Consulting Electrical Engineers 12358 20112 VAIL OWB OAKLEY SSV 20 November 2012 BEK BEK NOT ISSUED FOR CONSTRUCTION UNLESS SIGNED THROUGH THE SEAL IN BLUE INK OR DIGITALLY SIGNED BY BRYAN KAZIN. LIMITED TO ELECTRICAL. 36628 11/20/12 ELECTRICAL SPECIFICATIONS & LEGEND Reviewed for Code Compliance Code: 2009 International Building Code (IBC) By Martin Haeberle at 11:31 am, Nov 30, 2012 PANEL D 800A METER CENTER 9‘: (4 #3/0 CU , 1 #6 CU G) (200A) S T 30A, 1-POLE CONTACTOR FOR EXTERIOR SIGN 1 PARTIAL ONE-LINE DIAGRAM NOT TO SCALE NOTES: 1.EQUIPMENT, WIRING, AND DEVICES SHOWN LIGHT ARE EXISTING AND SHOWN DARK ARE NEW UNLESS OTHERWISE NOTED. 2.NEW WIRING SHALL BE THHN/THWN-2 INSULATED COPPER UNLESS OTHERWISE NOTED. EXIT AND EMERGENCY LIGHTING FIXTURE SCHEDULE DESCRIPTION OF LUMINAIRE LUMINAIRE SPECIFICATION SYMBOL DESCRIPTION FINISH MOUNTING INFO MANUFACTURER CATALOG NUMBER LAMP(S)VOLTAGE EXIT/EM LIGHT (UNIVERSAL)WHITE SEE PLAN EXITRONIX GVEX-U-BP-WH-EL95-G2 (ADD "R" IF POWERING REMOTE HEADS) LED + (2) 5.4W H.I.T. LAMPS 120/277 INPUT 6V BATTERY LIGHTING FIXTURE SCHEDULE PREPARED BY KAZIN & ASSOCIATES DESCRIPTION OF LUMINAIRE LUMINAIRE SPECIFICATION ID TOTAL FIXTURE QUANTITY TOTAL FIXTURE QUANTITY DESCRIPTION FINISH MOUNTING INFO MANUFACTURER CATALOG NUMBER LAMP(S)VOLTAGE A3 11 33 CONCEALED RECESSED ADJUSTABLE ACCENT LIGHT WHITE RECESSED IN GYP CON-TECH RAN15038-X2-P-WRL18 ***CUSTOMIZE: REMOVE SHROUD AROUND LAMP SOCKET TO ALLOW AIR TO CIRCULATE AROUND BACK OF LAMP*** PHILIPS ENDURA 18PAR38/END/ F25 3000 DIM SM (1200 LUMENS) 120 F2 4 16 SURFACE MOUNTED WATERPROOF INCANDESCENT - COPPER-FREE ALUM BODY, ALUM REFLECTOR, CLEAR LENS GLOBE, WING NUT ATTACHED CAST WIRE GUARD - MOUNT FIXTURE AT ƒ$1*/( CLR SURFACE - MOUNT WITH GALVANIZED HEXHEAD BOLTS PAULUHN 1440A TURTLE SHELL (4) PAR 38 / 50W 120 F10 2 2 FACTORY SEALED EVA GLOBE PENDANT FIXTURE ALUMINUM ASSEMBLY ON SITE REQ'D. PENDANT LIGHTING FIXTURE ASSEMBLY CONSISTS OF FLEXIBLE SO CORD W/ KELLEMS 073-03-1204 BUS DROP GRIP SINGLE WEAVE MESH; KELLEMS 073-04-1281 DUSTIGHT STRAIN RELIEF GRIP FIXTURE CONNECTOR. HUNG AT 6'-6" CROUSE HINDS EVA PENDANT 60PAR/HIR/S/FL 30, 60W 120 F14 1 3 (3) JELLY JAR WALL MOUNTED LIGHT FIXTURES WALL - MOUNT W/ GALVANIZED HEX HEAD BOLTS. CENTER LIGHT ABOVE MIRROR. CROUSE HINDS OR EQUAL (3) VJ-275 CONNECTED TOGETHER (3) 75W 120 H4 2 4 4' STRIP FLUORESCENT WITH WIREGUARD WHITE CHAIN COLUMBIA CS4-232-EU-CSWG4 (2) F32T8 120 J1 50 HEADS, TRACK LENGTH PER PLAN 50 TRACK LIGHTING WHITE SURFACE (CLG OR BOTTOM OF JOIST - SEE PLAN)CON-TECH TRACK: LT2 (LENGTH PER PLAN) + PENDANT MOUNTING ACCESSORIES-P (WHITE) HEADS: CTL603A-P (WHITE) WRL18 ***PROVIDE QUANTITY OF HEADS SHOWN ON LIGHTING PLAN*** PHILIPS ENDURA 18PAR38/END/ F25 3000 DIM SM (1200 LUMENS) 120 NOTES: 1.PROVIDE FLUORESCENT LAMPS RATED 3500K, 85CRI, AND ALL MADE BY THE SAME MANUFACTURER. 2.PROVIDE INTEGRAL DISCONNECT FOR EACH DOUBLE-ENDED FLUORESCENT FIXTURE TO DISCONNECT THE BALLAST FROM THE LAMP SOCKET. 3.PROVIDED HANGERS, ADAPTERS, INSTALLATION KITS, PARTS AND PIECES TO INSTALL THE SPECIFIED FIXTURE IN THE LOCATIONS SHOWN ON THE PLAN. Scale Project Number Date Drawn by Checked by On e W i l l o w B r i d g e C o m m e r c i a l , R e t a i l 2 Ea s t M e a d o w D r i v e , V a i l , C o l o r a d o 8 1 6 5 7 AS NOTED E0029364 Teddy Lane Suite 101, Lone Tree, CO 80124-2873 Project Number: Village Square at Lone Tree (720) 489-1609 Fax (720) 489-1611 2012C Est. 1984 Consulting Electrical Engineers 12358 20112 VAIL OWB OAKLEY SSV 20 November 2012 BEK BEK NOT ISSUED FOR CONSTRUCTION UNLESS SIGNED THROUGH THE SEAL IN BLUE INK OR DIGITALLY SIGNED BY BRYAN KAZIN. LIMITED TO ELECTRICAL. 36628 11/20/12 ONE-LINE DIAGRAM & SCHEDULES Reviewed for Code Compliance Code: 2009 International Building Code (IBC) By Martin Haeberle at 11:31 am, Nov 30, 2012 F Nesting Table Small F Nesting Table Ceiling Lighting Small F N e s t i n g Ta b l e Ce i l i n g L i g h t i n g M Mannequin H Rack S H Rack S Small F NestingTable Ceiling Lighting H R a c k S Ac c e s s o r y To w e r Small F Nesting Table Small Cube/ Pedestal Small Cube/ Pedestal Ac c e s s o r y To w e r Small F Nesting Table H R a c k S +96" +96" +96" +96" +56" +56" +96" ABOVE WINDOW ABOVE WINDOW ABOVE WINDOW ABOVE WINDOW ABOVE WINDOW 6" ROUND FLUSH MOUNTED FLOOR BOX; DIVIDED BOX FOR DUAL SERVICE (DATA/PHONE AND POWER); BLACK FACE PLATE AND DEVICES. ELECTRICAL TO INCLUDE CUTTING & PATCHING OF CONCRETE. (TYPICAL) SIGN D +96" +96"D-10 D-12 D-17 D-14 D-13 D-11 D-15 D-9 D-16 VIA TIME SWITCH A3 A3 A3 A3 A3 A3 A3 A3 A3 A3A3 F10 J1 J1 J1 J1 J1 J1 J1 J1 J1 J1 J1 F2 F2 F2 F2 F14 H4 H4 a b c d f a,ba,ba,b a,b a,b a,b a,b a,b a,b c c c c c CLG CLG CLG CLG CLG D-2 D-8 D-4 D-4 D-6 (2) 4A TRACK BREAKERS ddd d d d f f ff f F10 11 2 2 2 ALTERNATE CIRCUITS ON TRACK (TYPICAL) CONNECT TO NON-SWITCHED LEG OF LOCAL LIGHTING CIRCUIT. DETAIL NOTES NOTE 1 REFER TO DETAILS #3 AND #5 ON SHEET E100 FOR HANGING OF F10 LIGHT FIXTURES. REFER TO DETAIL #5 ON SHEET E100 FOR HANGING OF F10 LIGHT FIXTURES. 2 REFER TO DETAILS #4 AND #5 ON SHEET E100 FOR DROP-FEED TO DISPLAY CASE. Scale Project Number Date Drawn by Checked by On e W i l l o w B r i d g e C o m m e r c i a l , R e t a i l 2 Ea s t M e a d o w D r i v e , V a i l , C o l o r a d o 8 1 6 5 7 AS NOTED E1009364 Teddy Lane Suite 101, Lone Tree, CO 80124-2873 Project Number: Village Square at Lone Tree (720) 489-1609 Fax (720) 489-1611 2012C Est. 1984 Consulting Electrical Engineers 12358 20112 VAIL OWB OAKLEY SSV 20 November 2012 BEK BEK NOT ISSUED FOR CONSTRUCTION UNLESS SIGNED THROUGH THE SEAL IN BLUE INK OR DIGITALLY SIGNED BY BRYAN KAZIN. LIMITED TO ELECTRICAL. 36628 11/20/12 POWER PLAN & LIGHTING PLAN 3 POS HANGING FIXTURE DETAIL SCALE: 1/2" = 1'-0"4 DISPLAY CASE POWER FEED DETAIL SCALE: 1/2" = 1'-0"5 KELLEMS GRIP DETAIL FOR POS LIGHT AND DISPLAY CASE SCALE: 1/2" = 1'-0" Reviewed for Code Compliance Code: 2009 International Building Code (IBC) By Martin Haeberle at 11:32 am, Nov 30, 2012