Loading...
HomeMy WebLinkAboutF12-0095 Stamped approved AUTOMATIC FIRE SPRINKLER SYSTEM EQUIPMENT SUBMITTALS FOR ONE WILLOW BRIDGE RETAIL CS3- OAKLEY VAIL, CO. mirage® standard and Qr concealed pendent sprinkler vk462 and hp sprinkler vk463 (k5.6) technical data January 27, 2012 the viking corporation, 210 n industrial park drive, hastings mi 49058 telephone: 269-945-9501 technical services: 877-384-5464 Fax: 269-818-1680 email: techsvcs@vikingcorp.com 1. description Viking Mirage® Standard and Quick Response Concealed Pendent Sprinkler VK462 and HP Sprinkler VK463 are thermosensitive glass-bulb spray sprinklers designed for installation on concealed pipe systems where the appearance of a smooth ceiling is desired. The sprinkler is pre-assembled with a threaded adapter for installation with a low-pro-file cover assembly that provides up to ½” (12.7 mm) of vertical adjustment. The two-piece design allows installation and testing of the sprinkler prior to installation of the cover plate. The “push-on”, “thread-off” design of the concealed cover plate assembly allows easy installation of the cover plate after the system has been tested and the ceiling finish has been applied. The cover assembly can be removed and reinstalled, allowing temporary removal of ceiling panels without taking the sprinkler system out of service or removing the sprinkler. 2. listings and approvals cUlus listed: Category VNIV Fm approval: Class 2015 nYc approved: MEA 89-92-E, Volume 32 vds approved: Certificate G4080021 lpcB approved: Ref. No. 096e/12 ce certified: Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2032 Refer to Approval Chart 1 on page 54c and Design Criteria on page 54d for cULus Listing requirements, and refer to Approval Chart 2 and Design Criteria on page 54e for FM Approval requirements that must be followed. 3. technical data Specifications: Available since 2006. Minimum Operating Pressure: 7 psi (0.5 bar)* maximum Working pressure: sprinkler vk463 is rated for use with water working pressures ranging from the minimum 7 psi (0.5 bar) up to 250 psi (17.2 bar) for high-pressure systems. high-pressure (hp) sprinklers can be identified by locating “250” stamped on the deflector. sprinkler vk462 is rated to a maximum 175 psi (12 bar) wwp. Factory tested hydrostatically to 500 psi (34.5 bar) Thread size: 1/2” (15 mm) NPT Nominal K-Factor: 5.6 U.S. (80.6 metric†) Glass-bulb fluid temperature rated to -65°F (-55°C)Patents Pending *cULus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimumoperatingpressureforLPC��andCEinimum operating pressure for LPC�� and CE Approvals ONLY is 5 psi (0.35 bar). †Metric K-factor measurement shown is when pressure is measured in ��ar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. material standards: Sprinkler ��ody: ��rass UNS-C84400 Deflector: Copper UNS-C19500 for Sprinkler VK462 Phosphor ��ronze UNS-C51000 for Sprinkler VK463Deflector Pins: Stainless Steel Alloy��ulb: Glass, nominal 3 mm diameter Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400 ��utton: ��rass UNS-C36000 Screws: 18-8 Stainless Steel��elleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with Teflon Tape Yoke: Phosphor ��ronze UNS-C51000 Cover Adapter: Cold Rolled Steel UNS-G10080, Finish: Clear Chromate over Zinc Plating Form No. F_103005 Replaces page 54a-f, dated April 8, 2011. (Revised VdS Approval.) viking technical data may be found on the viking corporation’s Web site at http://www.vikinggroupinc.com. the Web site may include a more recent edition of this technical data page. Sprinkler 54a technical data January 27, 2012 the viking corporation, 210 n industrial park drive, hastings mi 49058 telephone: 269-945-9501 technical services: 877-384-5464 Fax: 269-818-1680 email: techsvcs@vikingcorp.com mirage® standard and Qr concealed pendent sprinkler vk462 and hp sprinkler vk463 (k5.6) cover assembly materials: Cover: Copper UNS-C11000 ��ase: ��rass UNS-C26000 or UNS-C26800Springs: Nickel Alloy Solder: Eutectic ordering information: (Also refer to the current Viking price list.) Viking Mirage® Standard and Quick Response Concealed Pendent Sprinklers and Cover Plate Assemblies must be ordered separately: sprinkler: ��ase Part No. 13503A or HP ��ase Part No. 13667A Specify sprinkler temperature rating by adding the appropriate suffix for the temperature rating to the base part number:Temperature Suffix: 155 °F (68 °C) = ��, 175 °F (79 °C) = D, 200 °F (93 °C) = E For example, sprinkler VK463 with a 155 °F (68 °C) temperature rating = 13667A��. cover plate assembly: ��ase Part No. 13504 (2-3/4” diameter), ��ase Part No. 13642 (3-5/16“ diameter), or ��ase Part No. 15394 (square cover plate, 3-5/16” diameter) Specify finish and temperature rating of the cover plate assembly by adding the appropriate suffixes for the finish and the cover temperature rating to the base part number: Finish Suffix: Polished Chrome = F, ��rushed Chrome = F-/��, ��right ��rass = ��, Antique ��rass = ��-/A, ��rushed ��rass = ��-/��, ��rushed Copper = E-/��, Painted White = M-/W, Painted Ivory = M-/I, Painted ��lack = M-/�� Temperature Suffix: 135 °F (57 °C) UL (139 °F (59 °C) FM and LPC��) = A, 165 °F (74 °C) = C For example, cover 13504 with a Polished Chrome finish and a 165 °F (74 °C) temperature rating = 13504FC. Note: Square cover plate 15394 cULus Listing is for the 135 °F (57 °C) temperature rated cover plate only. Refer to the Approval Chart. available Finishes and temperature ratings: Refer to Table 1. accessories: (Also refer to the “Sprinkler Accessories” section of the Viking data book.) sprinkler Wrenches**: A. Heavy Duty Wrench Part No. 14047W/�� (available since 2006), or��. Head Cabinet Wrench Part No. 14031*** (available since 2006) C. Optional Concealed Cover Plate Installer Tool Part No. 14412 for cover 13504, or Part No. 14867 for the large diameter cover (available since 2007) **Requires a ½” ratchet (not available from Viking). ***Optional for removal of the protective cap. Ideal for sprinkler cabinets. sprinkler cabinet: Part No. 01731A (available since 1971) 4. installation Refer to appropriate NFPA Installation Standards. 5. operation During fire conditions, when the temperature around the sprinkler approaches its operating temperature, the cover plate detaches. Continued heating of the exposed sprinkler causes the heat-sensitive liquid in the glass bulb to expand and the bulb to shatter, releasing the yoke, pip-cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. 6. inspections, tests and maintenance Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. availaBilitY Viking Sprinklers VK462 and VK463 are available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. gUaranteeFor details of warranty, refer to Viking’s current list price schedule or contact Viking directly. Sprinkler 54b mirage® standard and Qr concealed pendent sprinkler vk462 and hp sprinkler vk463 (k5.6) technical data January 27, 2012 the viking corporation, 210 n industrial park drive, hastings mi 49058 telephone: 269-945-9501 technical services: 877-384-5464 Fax: 269-818-1680 email: techsvcs@vikingcorp.com taBle 1: availaBle sprinkler temperatUre ratings and Finishes sprinkler temperature classification sprinkler nominal temperature rating1 maximum ambient ceiling temperature2 temperature rating of cover assembly (required)Bulb color Ordinary 155 °F (68° C)100 °F (38 °C)135 °F (57 °C) cULus 139 °F (59 °C) FM and LPC��Red Intermediate 175 °F (79 °C)150 °F (65 °C)165 °F (74 °C)Yellow Intermediate 200 °F (93 °C)150 °F (65 °C)165 °F (74 °C)Green cover plate Finishes: Polished Chrome, ��rushed Chrome, ��right ��rass, Antique ��rass, ��rushed ��rass, ��rushed Copper, Painted White, Painted Ivory, or Painted ��lack Footnotes 1 The sprinkler temperature rating is stamped on the sprinkler deflector. 2 ��ased on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. approval chart 1 (Ul) mirage® concealed pendent sprinklers vk462 and vk463 sprinkler Base part no.1 sin npt thread size nominal k-Factor maximum Water Working pressure listings and approvals4 (refer also to design criteria on page 54d.) inch mm U.s.metric2 cUlus5 nYc vds7 lpcB standard response applications 13503A VK462 1/2”15 5.6 80.6 175 psi (12 bar)----AY1, CZ1 AY1, ��Z1 AY1, CZ18 Quick response applications 13503A VK462 1/2”15 5.6 80.6 175 psi (12 bar)AV1, ��X1 AV1, ��W16 ------ 13667A VK463 1/2”15 5.6 80.6 250 psi (17.2 bar)3 AV1, ��X1 AV1, ��W16 ------ sprinkler temperature ratings A - 155 °F (68 °C) �� - 175 °F (79 °C) and 200 °F (93 °C) C - 200 °F (93 °C) cover plate assembly temperature ratings9 V - 135°F(57°C)cULusListedcover13504135 °F (57 °C) cULus Listed cover 135041, 136421 (large diam-eter), or 153941 (square cover plate)W - 165 °F (74 °C) cover 135041 or 136421 (large diameter) X - 165°F(74°C)cover13504165 °F (74 °C) cover 135041, or 136421 (large diameter) Y - 135 °F (57 °C) cover 135041 LPCB Approved as 139 °F (59 °C) Z - 165 °F (74 °C) cover 135041 cover plate assembly Finishes10 1 - Polished Chrome, ��rushed Chrome, ��right ��rass, Antique ��rass, ��rushed ��rass, ��rushed Copper, Painted White, Painted Ivory, or Painted ��lack Footnotes 1 Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 2 Metric K-factor measurement shown is when pressure is measured in ��ar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3 The Water Working Pressure rating is stamped on the deflector. 4 This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. 5 Listed by Underwriter’s Laboratories for use in the U.S. and Canada. 6 Accepted for use, City of New York Department of ��uildings, MEA Number 89-92-E, Vol. 32. 7 VdS Approved, standards VdS 2344:2005-12, VdS 2100-25:2008-01, and EN 12259-1:1999 + A1:2001 + A2:2004 + A3:2006, Certificate G4080021. 8 Certified, Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2032. 9 The 135/139 °F cover has an orange label. The 165 °F (74 °C) cover has a white label. 10Painted finish consists of Polyester ��aked Enamel. Other paint colors are available on request with the same listings as the standard paint colors. Listings and approvals apply for any paint manufacturer. Contact Viking for additional information. note: Custom colors are indicated on a label inside the cover assembly. Refer to Figure 1. Sprinkler 54c technical data January 27, 2012 the viking corporation, 210 n industrial park drive, hastings mi 49058 telephone: 269-945-9501 technical services: 877-384-5464 Fax: 269-818-1680 email: techsvcs@vikingcorp.com mirage® standard and Qr concealed pendent sprinkler vk462 and hp sprinkler vk463 (k5.6) Sprinkler 54d Figure 1: identification of custom paint color for concealed covers Figure 2: square cover assembly 15394 design criteria - Ul (Also refer to Approval Chart 1 on page 54c.) cUlus listing requirements: Mirage® Concealed Pendent Sprinklers VK462 and VK463 are cULus Listed as quick response for installation in accordance with the latest edition of NFPA 13 for standard coverage pendent spray sprinklers as indicated below. For hazard occupancies up to and including Ordinary Hazard, Group II. Protection areas and maximum spacing shall be in accordance with the tables provided in NFPA 13. Maximum spacing allowed is 15 ft. (4.6 m). Minimum spacing allowed is 6 ft. (1.8 m) unless baffles are installed in accordance with NFPA 13. Minimum distance from walls is 4 in. (102 mm). Maximum distance from walls shall be no more than one-half of the allowable distance between sprinklers. The distance shall be measured perpendicular to the wall. The sprinkler obstruction rules contained in NFPA 13 for standard coverage pendent spray sprinklers must be followed. note:concealedsprinklersmustbeinstalledinneutralornegativepressureplenumsonly.ote: concealed sprinklers mustbeinstalledinneutralornegativepressureplenumsonly.ust be installed in neutral or negative pressure plenums only. • • • • • • vds approval requirements: a) The sprinkler can be installed in a concrete ceiling (massive ceiling) or in a false ceiling made of light materials. b) This sprinkler is deflector fixed type and can be only activated by heat. The housing is not tight. c) Follow installation guidelines of current standards, CEA4001VdS and EN12845. These sprinklers can only be installed in LH and OH occupan-cies, except in OH4. notes: Due to the design the sprinkler type ‘Domed-CCP’ shall not be installed in false ceilings in which the false ceiling space is protected by a water extinguishing system. Due to the design the sprinkler type ‘Domed-CCP’ shall not be installed in false ceilings in which during a fire the pressure above the false ceiling may be assumed to be higher than the pressure below the false ceiling. The criterion for the dropping of the cover relevant for this approval is heat. Steps of installation: Prepare the sprinkler key. Remove the plastic cover. Hold the sprinkler with the wrench and fasten it. Replace the plastic cover and do not remove until the cover is installed. 1. 2. 3. 4. important: always refer to Bulletin Form no. F_091699 - care and handling of sprinklers. also refer to page sr1-3 or Qr1-3 for general care, installation, and maintenance information. viking sprinklers are to be installed in accordance with the latest edition of viking technical data, the appropriate standards of nFpa, lpcB, apsad, vds or other similar organizations, and also with the provisions of governmental codes, ordinances, and stan-dards, whenever applicable. mirage® standard and Qr concealed pendent sprinkler vk462 and hp sprinkler vk463 (k5.6) technical data January 27, 2012 the viking corporation, 210 n industrial park drive, hastings mi 49058 telephone: 269-945-9501 technical services: 877-384-5464 Fax: 269-818-1680 email: techsvcs@vikingcorp.com Sprinkler 54e design criteria - Fm (Also refer to Approval Chart 2 above.) Fm approval requirements: Viking Concealed Pendent Sprinkler VK462 is FM Approved as a standard response non-storage concealed pendent sprinkler as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. note: the Fm installation guidelines may differ from cUlus and/or nFpa criteria. important: always refer to Bulletin Form no. F_091699 - care and handling of sprinklers. also refer to page sr1-3 for general care, installation, and maintenance information. viking sprinklers are to be installed in ac-cordance with the latest edition of viking technical data, the appropriate standards of nFpa, Fm global, lpcB, apsad, vds or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. approval chart 2 (Fm) mirage® standard response concealed pendent sprinkler vk462 sprinkler Base part no.1 sin npt thread size nominal k-Factor maximum Water Working pressure Fm approvals3 (refer also to design criteria below.)inch mm U.s.metric2 13503A VK462 1/2”15 5.6 80.6 175 psi (12 bar)AW1, ��X1 sprinkler temperature ratings A - 155 °F (68 °C) �� - 175 °F (79 °C) and 200 °F (93 °C) cover plate assembly temperature ratings4 W - 139°F(59°C)cover13504139 °F (59 °C) cover 135041, 136421 (large diameter), or 153941 (square cover plate) X - 165°F(74°C)cover13504165 °F (74 °C) cover 135041, 136421 (large diameter), or 153941 (square cover plate) cover plate assembly Finishes5 1 - Polished Chrome, ��rushed Chrome, ��right ��rass, Antique ��rass, ��rushed ��rass, ��rushed Copper, Painted White, Painted Ivory, or Painted ��lack Footnotes 1 Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 2 Metric K-factor measurement shown is when pressure is measured in ��ar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3 This chart shows the FM Approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. 4 The 139 °F (59 °C) cover has an orange label. The 165 °F (74 °C) cover has a white label. 5 Painted finish consists of Polyester ��aked Enamel. Otherpaintcolorsareavailableonrequestwiththesamelistingsasthestandardpaintcolors.Other paint colors are available on request with the same listings as the standard paint colors. Listings and approvals apply for any paint manufacturer. Contact Viking for additional information. note: Custom colors are indicated on a label inside the cover assembly. Refer to Figure 1. technical data January 27, 2012 the viking corporation, 210 n industrial park drive, hastings mi 49058 telephone: 269-945-9501 technical services: 877-384-5464 Fax: 269-818-1680 email: techsvcs@vikingcorp.com mirage® standard and Qr concealed pendent sprinkler vk462 and hp sprinkler vk463 (k5.6) Form No. F_103005 Sprinkler 54f Figure 4: sprinkler dimensions and cover installation Figure 3: sprinkler installation and correct Use of Wrenches Replaces page 54a-f, dated April 8, 2011. (Revised VdS Approval.) Wheatland’s Schedule 40 Sprinkler Pipe is a high quality sprinkler pipe offering you the full range of assurances you require. Schedule 40 Sprinkler Pipe has passed some of the toughest lab tests ever created for sprinkler pipe. Wheatland’s schedule 40 Sprinkler Pipe is made from the highest quality steel in one of the nation’s most modern and most complete pipe manufacturing plants. Our proprietary mill coating offers you a clean, corrosion and heat resistant surface that outlasts and outperforms standard lacquer coatings. Plus, this coating can be quickly and easily painted without special preparation. Or it may be hot-dipped galvanized to meet FM requirements for dry systems in accordance with the zinc coating specifi cation of ASTM A795. Schedule 40 is also available as ASTM A 53 in NPS 1 - 6 and is UL & C-UL Listed and FM Approved. Wheatland’s Schedule 40 Standard Wall Sprinkler Pipe meets or exceeds the following: UL & C-UL Listed• FM Approved• ASTM A795, Type E, Grade A• Sprinkler Pipe Specifi cations NPS Nominal O.DNominal I.DNominal WallNominal Weight UL CRR*Pieces Lift in.mmin.mmin.mmlbs./ft.kg/m 1”1.31533.41.04926.6.1333.381.682.501.0070 1 1/4”1.66042.21.38035.1.1403.562.273.391.0051 1 1/2”1.90048.31.61040.9.1453.682.724.051.0044 2”2.37560.32.06752.5.1543.913.665.451.0030 * Calculated using Standard UL CRR formula, UL Fire Protection Directory, Category VIZY * The CRR is a ratio value used to measure the ability of a pipe to withstand corrosion. Threaded Schedule 40 steel pipe is used as the benchmark (value of 1.0). Please refer to appropriate documentation for up-to-date listing and approval information. Specifi cations and descriptions are accurate as known at time of publication and are subject to change without notice. Wheatland’s Made in the U.S.A. by Wheatland Tube Company means made to the highest standards for consistant quality. Specifi cations and Approvals 700 South Dock Street, Sharon, PA 16146 Ph 800.257.8182 Fax 724.346.7260 www.wheatland.com Wheatland Tube Company 0309 1.0Mrev02 Effective February 23, 2009 Coated Black Sprinkler Pipe Page 40 D.I. THREADED FITTINGS For fire protection services request submittal GRS 1.3 DUCTILE IRON 90 DEG. ELBOW NOMINALITEMMAX.WEIGHT SIZECODEWORKING EACH (INCH)#P.S.I.ABPIECE 1DB900335001.501.500.62 1 1/4DB900445001.751.750.90 1 1/2DB900555001.941.941.20 2DB900665002.252.251.85 DIMENSIONS DUCTILE IRON STRAIGHT TEE NOMINALITEMMAX.WEIGHT SIZECODEWORKING EACH (INCH)#P.S.I.ABPIECE 1DT3335001.501.500.85 1 1/4DT4445001.751.751.22 1 1/2DT5555001.941.941.55 2DT6665002.252.252.45 DIMENSIONS DUCTILE IRON RED.90 DEG. ELBOW NOMINALITEMMAX.WEIGHT SIZECODEWORKING EACH (INCH)#P.S.I.ABPIECE 1X1/2DB900315001.261.360.44 1X3/4DB900325001.371.450.52 1 1/4X1/2DB900415001.341.530.64 1 1/4X3/4DB900425001.451.620.72 1 1/4X1DB900435001.581.670.75 1 1/2X1DB900535001.651.800.92 1 1/2X1 1/4DB900545001.821.881.08 2X1/2DB900615001.491.881.08 2X3/4DB900625001.601.971.24 2X1DB900635001.732.021.40 2X1 1/4DB900645001.902.101.52 2X1 1/2DB900655002.022.161.65 DIMENSIONS DUCTILE IRON COUPLING NOMINALITEMMAX.DIMENSIONWEIGHT SIZECODEWORKINGEACH (INCH)#P.S.I.APIECE 1DCL0335001.670.40 1 1/4DCL0445001.930.57 1 1/2DCL0555002.150.75 2DCL0665002.531.15 DUCTILE IRON RED. COUPLING NOMINALITEMMAX.DIMENSIONWEIGHT SIZECODEWORKINGEACH (INCH)#P.S.I.APIECE 1X1/2DRC0315001.690.39 1X3/4DRC0325001.690.53 DUCTILE IRON 45 DEG. ELBOW NOMINALITEMMAX.WEIGHT SIZECODEWORKING EACH (INCH)#P.S.I.ABPIECE 1DB450335001.121.120.46 1 1/4DB450445001.291.290.73 1 1/2DB450555001.431.430.92 2DB450665001.681.681.50 DIMENSIONS DUCTILE IRON THREADED FITTINGS ARE UL, ULC LISTED AND FACTORY MUTUAL APPROVED FOR 500 PSI SERVICE. DUCTILE IRON PER ASTM A 536 GRADE 65-45- 12. DIMENSIONS CONFORM TO ANSI B16.3 CLASS 150. THREADS ARE NPT PER ANSI/ASME B1.20.1 NOTICE: DUCTILE IRON FITTINGS HAVE HIGHER TENSILE STRENGTH THEN THAT OF STEEL PIPE. THEREFORE, OVER TIGHTENING CAN CAUSE DAMAGE TO PIPE THREADS WHICH MAY CAUSE LEAKAGE. DUCTILE IRON FITTINGS SHOULD BE TIGHTENED THREE TURNS BEYOND HAND TIGHT, BUT NO MORE THAN FOUR TURNS. A Page 41 DUCTILE IRON REDUCING TEE NOMINALITEMMAX.WEIGHT SIZECODEWORKINGEACH (INCH)#P.S.I.ABCPIECE 1X1X1/2DT3315001.261.261.360.64 1X1X3/4DT3325001.371.371.450.73 1X1/2X1DT3135001.501.361.500.71 1X3/4X1DT3235001.501.451.500.76 1X1X1 1/4DT3345001.671.671.580.98 1X1X1 1/2DT3355001.801.801.651.16 1 1/4X1X1/2DT4315001.341.261.530.82 1 1/4X1X3/4DT4325001.451.371.620.90 1 1/4X1X1DT4335001.581.501.671.00 1 1/4X1X1 1/4DT4345001.751.671.751.08 1 1/4X1X1 1/2DT4355001.881.801.821.42 1 1/4X1 1/4X1/2DT4415001.341.341.530.86 1 1/4X1 1/4X3/4DT4425001.451.451.620.92 1 1/4X1 1/4X1DT4435001.581.581.670.95 1 1/4X1 1/4X1 1/2DT4455001.881.881.821.45 1 1/4X1 1/4X2DT4465002.102.101.901.75 1 1/2X1X1/2DT5315001.411.341.660.95 1 1/2X1X3/4DT5325001.521.371.751.14 1 1/2X1X1DT5335001.651.501.801.17 1 1/2X1X1 1/4DT5345001.821.671.881.34 1 1/2X1X1 1/2DT5355001.941.801.941.45 1 1/2X1 1/4X1/2DT5415001.411.341.661.05 1 1/2X1 1/4X3/4DT5425001.521.451.751.15 1 1/2X1 1/4X1DT5435001.651.581.801.25 1 1/2X1 1/4X2DT5465002.162.102.021.90 1 1/2X1 1/2X1/2DT5515001.411.411.161.15 1 1/2X1 1/2X3/4DT5525001.521.521.751.24 1 1/2X1 1/2X1DT5535001.651.651.801.30 1 1/2X1 1/2X1 1/4DT5545001.821.821.881.48 1 1/2X1 1/2X2DT5565002.162.162.021.98 2X1X2DT6365002.252.022.252.15 2X1 1/4X2DT6465002.252.102.252.30 2X1 1/2X1/2DT6515001.491.411.881.50 2X1 1/2X3/4DT6525001.601.521.971.62 2X1 1/2X1DT6535001.731.652.021.64 2X1 1/2X1 1/4DT6545001.901.822.101.80 2X1 1/2X1 1/2DT6555002.021.942.162.00 2X1 1/2X2DT6565002.252.162.252.35 2X2X1/2DT6615001.491.491.881.60 2X2X3/4DT6625001.601.601.971.68 2X2X1DT6635001.731.732.021.85 2X2X1 1/4DT6645001.901.902.102.04 2X2X1 1/2DT6655002.022.022.162.18 2X2X2 1/2DT5565002.602.602.393.61 2 1/2X2X3/4DT7625001.741.602.322.28 DIMENSIONS DUCTILE IRON CAP NOMINALITEMMAX.DIMENSIONWEIGHT SIZECODEWORKINGEACH (INCH)#P.S.I.APIECE 1DCP0035001.160.32 1 1/4DCP0045001.280.43 1 1/2DCP0055001.330.60 2DCP0065001.450.91 DUCTILE IRON CROSS NOMINALITEMMAX.WEIGHT SIZECODEWORKING EACH (INCH)#P.S.IABPIECE 1DX0335001.501.500.98 1 1/4DX0445001.751.751.50 1 1/2DX0555001.941.941.90 2DX0665002.252.252.95 1 1/4X1DX0435001.581.671.27 1 1/2X1DX0535001.651.801.48 2X1DX0635001.732.022.10 DIMENSIONS DT667 DUCTILE IRON BUSHINGS NOMINALITEM SIZECODE (INCH)# DIMENSIONS 1x1/2DBUSH310.750.251.42OUT 1x3/4DBUSH320.750.251.42OUT 1 1/4x1DBUSH430.800.281.76OUT 1 1/2x1DBUSH530.830.312.00OUT 1 1/2x1 1/4DBUSH540.830.312.00OUT 2x1DBUSH630.880.411.95IN 2x1 1/4DBUSH640.880.342.48OUT 2x1 1/2DBUSH650.880.342.48OUT 0.22 0.17 0.28 0.44 0.30 0.66 0.72 0.61 DIMENSIONS ABCSTYLE WT. EACH D.I. THREADED FITTINGS For fire protection services request submittal GRS 1.3 OUTSIDE HEADINSIDE HEAD Main Office/Manufacturing Facility•1375 Sampson Ave. •Corona, CA 92879 •Ph: 909.737.5599 •Fax: 909.737.0330 Customer Service•800.786.5266 www.tolco.com 86 wwwwww..ttoollccoo..ccoomm Revision 5/24/2001 ™ ®a brand of Fig.200 - “Trimline”Adjustable Band Hanger Size Range — 1/2" thru 8" pipe Material — Carbon Steel, Mil.Galvanized to G90 specifications Function — For fire sprinkler and other general piping purposes.Knurled swivel nut design permits hanger adjustment after installation. Features — •(1/2" thru 2") Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion.Captured design keeps adjusting nut from separating with hanger.Hanger is easily installed around pipe. •(21/2" thru 8" Spring tension on nut holds it securely in hanger before installation.Adjusting nut is easily removed. Approvals — Underwriters’Laboratories listed (1/2" thru 8") in the USA (UL)and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (3/4" thru 8").Conforms to Federal Specifications WW-H-171E, Type 10 and Manufacturers Standardization Society SP-69, Type 10. Maximum Temperature — 650°F Finish — Mil.Galvanized.For Stainless Steel materi- als, order TOLCO™ Fig.200WON. Order By — Figure number and pipe size Dimensions • Weights Pipe Rod SizeMax.Rec.Approx. SizeInchMetric ABLoad Lbs.Length 1/23/88mm or 10mm31/8 25/8 40011 3/43/88mm or 10mm31/8 21/2 40011 13/88mm or 10mm33/8 25/8 40012 11/4 3/88mm or 10mm33/4 27/8 40013 11/2 3/88mm or 10mm37/8 27/8 40014 23/88mm or 10mm41/2 340015 21/2 3/810mm55/8 41/8 60027 33/810mm57/8 460029 31/2 3/810mm73/8 51/4 60034 43/810mm73/8 5100035 51/212mm91/8 61/4 125066 61/212mm101/8 63/4 125073 81/212mm131/8 83/4 1250136 OFFICE/MANUFACTURING FACILITY•1375 SAMPSON AVE. •CORONA, CA 92879 •PH: 951.737.5599 •FAX: 951.737.0330 CUSTOMER SERVICE•800.786.5266 www.tolco.com 66 wwwwww..ttoollccoo..ccoomm™ ®a brand of Revision 9/22/2001 Fig.65 andFig.66 ReversibleC-TypeBeamClamps 3/4" and11/4" ThroatOpenings Size Range — (Fig.65 and Fig.66) 3/8", 1/2" and 5/8" rod Material — Carbon Steel with hardened cup point set screw and jam nut Function — Recommended for hanging from steel beam where flange thickness does not exceed 3/4" (Fig.65) or 11/4" (Fig.66). Features — All steel construction eliminates structural deficiencies associated with casting type beam clamps.May be used on top or bot- tom flange of the beam.(Beveled lip allows hanging from top flange where clearance is limited.) May be installed with set screw in up or down position.Offset design permits unlimited rod adjustment by allowing the rod to be threaded completely through the clamp.Open design permits inspection of thread engagement. Approvals — Underwriters’Laboratories Listed in the USA (UL)and Canada (cUL).Factory Mutual Engineering approved.Conforms to Federal Specification WW-H-171E, Type 23 and Manufacturers Standardization Society SP-69, Type 19.Exceeds requirements of the National Fire Protection Association (NFPA), Pamphlet 13, 3/8" rod will support 1/2" thru 4" pipe, 1/2" rod will support 1/2" thru 8" pipe. Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD).For additional load, spacing and placement relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines. Finish — Plain Note — Available in Electro-Galvanized and HDG finish. Order By — Figure number, rod size and finish Fig.65 Patent #4,570,885 Dimensions • Weights Rod Size Max.Rec.Approx.A B CDEFLoad Lbs.*Wt./100 3/813/16 3/417/16161028 1/211/2 3/419/1611/4 113055 5/811/2 3/419/1611/4 113055 * Max.loads for clamp with set screw in up or down position. Fig.65 Dimensions • Weights Rod Size Max.Rec.Approx.A B CDEFLoad Lbs.*Wt./100 3/813/16 11/4 17/16161028 1/211/2 11/4 19/1611/4 113055 5/811/2 11/4 19/1611/4 113055 * Max.loads for clamp with set screw in up or down position. Fig.66 Component of State of California OSHPD Approved Seismic Restraints System OFFICE/MANUFACTURING FACILITY•1375 SAMPSON AVE. •CORONA, CA 92879 •PH: 951.737.5599 •FAX: 951.737.0330 CUSTOMER SERVICE•800.786.5266 www.tolco.com 70 wwwwww..ttoollccoo..ccoomm™ ®a brand of Revision 8/15/2005 Size Range — Secures 3/8" thru 7/8" hanger rod Material — Carbon Steel Function — Secures channel to hanger rod for vertical seismic bracing. Approvals — Underwriters Laboratories Listed in the USA(UL) and Canada (cUL).Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines Finish — Electro Galvanized Note — Available in HDG finish or Stainless Steel materials. Order By — Figure number Fig.98 - Rod Stiffener Fig.99 - All ThreadRodCut to Length Size Range — Secures 3/8" thru 7/8" rod in 1" increments Material — Carbon Steel Maximum Temperature — 750°F Finish — Plain Note — Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By — Figure number, rod diameter, rod length and finish Fig.100 - All ThreadRodFullLengths Size Range — Secures 3/8" thru 7/8" rod in 10’lengths Material — Carbon Steel Maximum Temperature — 750°F Finish — Plain Note — Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By — Figure number, rod diameter and finish Dimensions • Weights RodMax.Rec.Load Lbs. SizeFor Service Temps 650°F750°F 3/8610540 1/211301010 5/818101610 3/427102420 7/837703360 Dimensions • Weights Max Rec.Load Lbs. RodFor Service TempsApprox. Size650°F750°FWt./100 1/424021512 3/861054029 1/21130101053 5/81810161084 3/427102420123 7/837703360169 149604420222 11/4 80007140360 11/2 1163010370510 Component of State of California OSHPD Approved Seismic Restraints System