Loading...
HomeMy WebLinkAboutB12-0626 comments Date: 12/19/2013 Re: B12-0626 241 E Meadow Drive Dear Mr. Peterson RESPONSE INSTRUCTIONS ● Submit two complete sets of revised construction documents containing the requested information with all plan revision items clouded or otherwise identified. ● Please respond in writing to each comment with a response letter addressing each comment. BUILDING COMMENTS Architectural Comments: 1. Show compliance for accessibility for point of sale per section 1109.11.3 IBC 2009 edition. 2. Please clarify if yogurt dispensers are to be dispensed by the public. If so show how accessibility for reach and maneuvering clearance is obtained. Reference section 1109.12 IBC Structural Comments: Na Plumbing Comments: 1. Provide a complete plumbing plan showing actual location of drains and water piping to include existing sizing. Reference section 106.3.1 IPC 2009 edition. 2. Show how drainage is going to an approved grease interceptor as required by section 1003.1 IPC 2009 edition. Include sizing 3. Plan to reflect compliance for cross connection protection if beverage dispensers to be provided. Reference section 608.16 IPC. Please clarify 4. Plans to reflect tempered water per section 607.1 IPC 5. Water heater specifications provided. Plans do not reflect the installation of a new hot water heater. Provide plans showing code compliance for the installation of the new hot water heater Mechanical Comments: NA Electrical Comments: 1. Provide wiring method to be used as required for Assembly occupancies 2 Relocate the automatic door opener button to be in compliance with A117.1 ANSI PLANNING COMMENTS NA FIRE COMMENTS NA PUBLIC WORKS COMMENTS NA Sincerely, Martin A. Haeberle Chief Building Official