Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
B12-0309 REV 10 plans approved
UP DN UP DN UP A3.11 A3.2 1 A3.1 A3.2 2 2 2 3 4 1 B B A A C C 5 55' - 4" 46 ' - 8 " FINISH 45' - 2 1/2" 16' - 4" (F.V.) 24' - 2 1/4" (F.V.) 31' - 1 3/4" 14' - 0" 16' - 4" 6' - 7 1/2" 8' - 0 3/4" POLE OFFICE 110 WOMEN 114MEN 113 BIO DECON 119 AIR FILL STATION 118 WORK/TOOLS 117 EMERGENCY GENERATOR 116 TOILET 111 ENTRY 120 HALL 123 JAN 115 A2.2 3 A5.1 1 A5.2 1 1 A4.1 2 A4.1 1 A4.2 1 A4.3 2 A4.2 2 A4.3 3 A4.3 3' - 8" 114 111 E101 112 E103 E105 E104 110B HOSE DRY 112 WEST STAIR 122 OFFICE 125 APPARATUS 124 STAIR 121 WATER ENTRY 126 13' - 4" 11' - 7 7/8"8' - 0 3/8" 4' - 8 5/8" 4' - 4 1/8" 15' - 7 1/4" 10' - 5 5/8" 8' - 1 1/2" 11' - 0 3/8" 4' - 2 1/8" 110 8' - 5 3/8" 7' - 4" 5' - 4" 6' - 8 5/8" 2 A4.4 4' - 2 7/8" 4' - 8" 1 1 4' - 2 1/2" 2' - 6 1/4" 4' - 4 7/8" 15' - 8 1/8" 4' - 1 1/4"8' - 7 5/8" E108 E107 E100 116 11" 1 11" 7' - 10 7/8" CLR 3' - 1 1/8" 10" A14.17 Type G 8" 18' - 3"1 119 118 120 I.T. 127 STORAGE 128 1' - 10 7/8" 6 1 E106 5 4A 4 6 6 7 6 6 5 4A 4 J-BOX FOR EMERGENCY DISPATCH PHONE. TOP AT 48" MAXIMUM ABOVE FINISH FLOOR DOOR BELL BUTTON AT 48 " MAXIMUM ABOVE FINISH FLOOR 9' - 1" AED AT 48" AFF. LINK TO FACP PER OWNER REQUIREMENTS DOOR BELL BUTTON AT 48 " MAXIMUM ABOVE FINISH FLOOR. RINGS TO DOOR BELL BUTTON AT 48 " MAXIMUM ABOVE FINISH FLOOR. PROVIDE CHIME AT UPPER LEVEL WEST STAIR LANDING (VERIFY LOCATION WITH OWNER 5 5 DOOR BELL CHIME 5 9' - 7 5/8" 8' - 8"11' - 3 7/8" 4' - 3 3/8" J-BOX FOR PROXY CARD READER AT 48" AFF 5 J-BOX FOR PROXY CARD READER AT 48" AFF 5 J-BOX FOR PROXY CARD READER AT 48" AFF 5 5 6' - 11 1/2" 4' - 0" 13' - 8 1/8"5' - 4 1/4" 2' - 1"3' - 4 3/8" 5' - 4 1/4" 11' - 6 3/4" 3' - 1 1/2" - --- - --- 12' - 11 3/8" - - 29' - 6 3/4" 2" S/O vent 11' - 1 1/4" 8 8 CLR 10' - 0" 5 5/8" 8 7 5/8" 115 2 3 4 1 BA C 5 8' - 5 3/8" 15' - 2 3/4" 7' - 2 3/8" 5' - 5 5/8" 8' - 1 3/4" MEZZANINE STORAGE MEZZANINE STORAGE MEZZANINE STORAGE 12' - 8 1/8" 29' - 11 3/4" MEZZANINE 130 1 5' - 1 1/2" 5' - 10 1/4" 4" Concrete Slab4" Concrete Slab4" Concrete Slab4" Concrete Slab4" Concrete Slab4" Concrete Slab MEZZANINE STORAGE 245 OPEN MEZZANINE 246 TYPE 1 TYPE 1A - FULL HEIGHT TO BOTTOM OF ROOF STRUCTURE TYPE 2 - INTERIOR DEMISING WALL TO UNDERSIDE OF ROOF STRUCTURE 1 LAYER 5/8" GYPSUM WALL BOARD 2X4 WOOD STUDS @ 16" O. C. WITH SOUND BATTS 1 LAYER 5/8" GYPSUM WALL BOARD 1 LAYER 5/8" GYPSUM WALL BOARD 2X4 WOOD STUDS @ 16" O. C. WITH SOUND BATTS 1 LAYER 5/8" GYPSUM WALL BOARD 2 LAYER 5/8" TYPE X GYPSUM WALL BOARD 2X4 WOOD STUDS @ 16" O. C. WITH SOUND BATTS 2 LAYER 5/8" TYPE X GYPSUM WALL BOARD PROVIDE SLIP TRACK WITH ACOUSTIC ISLOATION AT TOP OF ALL CONNECTIONS TO UNDERSIDE OF STRUCTURE, TYPICAL. PROVIDE SLIP TRACK WITH ACOUSTIC ISLOATION AT TOP OF ALL CONNECTIONS TO UNDERSIDE OF STRUCTURE, TYPICAL. INTERIOR WALL TYPES TYPE 3 2X4 WOOD STUD FURRING @ 16" O. C. 1 LAYER 5/8" GYPSUM WALL BOARD TYPE 4 1 LAYER 5/8" GYPSUM WALL BOARD 2X6 WOOD STUDS @ 16" O. C. WITH SOUND BATTS 1 LAYER 5/8" GYPSUM WALL BOARD TYPE 5 4" CMU - REINFORCED PER STRUCTURAL ACRYLIC ENAMEL PAINT OR TILE PER FINISH SCHEDULE TYPE 6 6" CMU - REINFORCED PER STRUCTURAL ACRYLIC ENAMEL PAINT OR TILE PER FINISH SCHEDULE 1 EXISTING TO REMAIN- FIELD VERIFY ISSUE RECORD 1650 Fallridge Road, Suite C-1 Vail, CO 81657 f.(970) 476-4901 p.(970)476-6342 42 W E S T M E A D O W D R I V E VA I L , C O 8 1 6 5 7 8 ASI 010 28 NOV 2012 A2.1 LEVEL 1 AND MEZZANINE PLANS FI R E S T A T I O N # 2 R E N O V A T I O N PR O J E C T # 1 2 0 4 16 JUL 2012 3/16" = 1'-0"1 Level 1 Plan Room Finish Schedule - Level 1 Room NumberRoom NameFloor FinishBase FinishWall FinishCeiling Finish 110OFFICECARPET TILERESILIENT BASEPAINT-SEMIGLOSSPAINTED GYP BD -SEMIGLOSS 111TOILETSEALED CONCNONEPAINT-SEMIGLOSSPAINTED GYP BD -SEMIGLOSS 112HOSE DRYSEALED CONCNONEPAINT-SEMIGLOSSPAINTED GYP BD -SEMIGLOSS 113MENPORCELAIN TILEPORCELAIN TILEPORCELAIN TILEPAINTED GYP BD -SEMIGLOSS 114WOMENPORCELAIN TILEPORCELAIN TILEPORCELAIN TILEPAINTED GYP BD -SEMIGLOSS 115JANSEALED CONCRESILIENT BASEPAINT-SEMIGLOSSPAINTED GYP BD -SEMIGLOSS 116EMERGENCY GENERATOR SEALED CONCNONEACRYLIC EPOXY GLOSSACRYLIC EPOXY GLOSS GYP BD 117WORK/TOOLSSEALED CONCNONEACRYLIC EPOXY GLOSSACRYLIC EPOXY GLOSS GYP BD 118AIR FILL STATIONSEALED CONCNONEACRYLIC EPOXY GLOSSACRYLIC EPOXY GLOSS GYP BD 119BIO DECONSEALED CONCNONEACRYLIC EPOXY GLOSSACRYLIC EPOXY GLOSS GYP BD 120ENTRYSEALED CONCRESILIENT BASEPAINT-SEMIGLOSSPAINTED GYP BD -SEMIGLOSS 121STAIRRUBBERRESILIENT BASEPAINT-SEMIGLOSSPAINTED GYP BD -SEMIGLOSS 122WEST STAIRRUBBERRESILIENT BASEPAINT-SEMIGLOSSPAINTED GYP BD -SEMIGLOSS 123HALLSEALED CONCRESILIENT BASEACRYLIC EPOXY GLOSSPAINTED GYP BD -SEMIGLOSS 124APPARATUSSEALED CONCNONEACRYLIC EPOXY GLOSSACRYLIC EPOXY GLOSS GYP BD 125OFFICECARPET TILERESILIENT BASEPAINT-SEMIGLOSSPAINTED GYP BD -SEMIGLOSS 126WATER ENTRYSEALED CONCNONE PAINT-SEMIGLOSSPAINTED GYP BD -SEMIGLOSS 127I.T.SEALED CONCNONEPAINT-SEMIGLOSSPAINTED GYP BD -SEMIGLOSS 128STORAGESEALED CONCNONEPAINT-SEMIGLOSSPAINTED GYP BD -SEMIGLOSS 130MEZZANINEPLYWOODNONEPAINT-SEMIGLOSSPAINTED GYP BD -SEMIGLOSS 3/16" = 1'-0"2 Mezzanine Level Plan 1 1 1 U305/U340-1HOUR U905-1HOUR (8"CMU) U906-1HOUR (6"CMU) RATEDWALLULASSEMBLIES FireAssemblies 06DEC2012 1HOURFLOOR/ CEILING-IBC ITEM 21-1.1 or 26-1.1 Reviewed for Code Compliance Code: 2009 International Building Code (IBC) By Martin Haeberle at 10:55 am, Dec 20, 2012 DN DN 2 3 4 1 B B A A C 5 8' - 1 " 24' - 1 5/8" UTILITY 215 BEDROOM 222 BEDROOM 219 BEDROOM 220 BEDROOM 221 TOILET 216 TOILET 217 HALL 223 HALL 214 STORAGE 212 POLE 213 STORAGE 218 MECHANICAL 211 A5.1 2 A5.2 2 A2.2 4 1 A4.1 2 A4.1 1 A4.2 2 A4.2 2 A4.3 3 A4.3 Steel alt tread access to tower antenna level above 24' - 4 5/8"1' - 3 7/8"29' - 9 5/8" 3' - 7 1 / 2 " 10' - 4 1/4"10' - 4 1/4" 11 ' - 6 " 5' - 11 1/4"4' - 1 1/8"5' - 7 5/8"5' - 10 5/8" 9' - 1 3/8" 4' - 5 1 / 2 " 3' - 2 1 / 4 " 8' - 10 1/8" 3' - 6" 4 1/4" 8' - 7 7 / 8 " 2' - 4 1 / 2 " 13 ' - 4 " 16 ' - 4 " 14 ' - 0 " 16 ' - 4 " 24' - 2 1/4"31' - 1 3/4" 8" 10' - 4" 11 ' - 0 3 / 8 " 1' - 4 7 / 8 " 1A 2 2 2 210 214 215 217 218 219 220 221 222 212 213 211 216 1A NORTH STAIR 210 WEST STAIR 226 KITCHEN 224 LIVING 225 1A 1 1A 1 1 1A 1 1A 1A 13 1 3 1A 1 1A1A 1 1 1A 1A 3 1A 3 2 10' - 4 1/4" 1 18' - 1 3/8" 4' - 2 1 / 2 " 2' - 1 1/4" 13' - 6 1/4" 15' - 0" 3' - 0 3/4" 14 ' - 0 7 / 8 " E203 E203B E202 TOILET 228 228 E201 DECK DECK DECK OPEN BELOW 2 A4.4 CL STRUCTURE 11' - 2" CL S T R U C T U R E 11 ' - 2 " 4' - 1 1/2"4' - 0 1/8" 3' - 7 1 / 8 " 3 1A 9' - 1 0 7 / 8 " 3' - 0 " 1A1 1A 1 1.5" LW Concrete Over Existing Deck 4' - 1 7 / 8 " EXIST AT CMU 15' - 10 1/2"5' - 1 " 3' - 6 " 2' - 6 3/4" 7' - 11 3/8" 9' - 11 3/8"9' - 11 3/8"9' - 11 3/8" 30' - 7 7/8" 13 ' - 2 " 44 ' - 1 1 1 / 2 " 12' - 3 5/8" 8 3/4" 4' - 4" 12' - 8 1/2" 2' - 7 7/8" 2' - 1 1 " 24' - 5 5/8" 63 ' - 2 1 / 4 " 5' - 2 3/4" 8' - 9 1/8" 5' - 7 5/8"2' - 3"2' - 3" 2' - 5 1 / 2 " 4' - 8 1/4" 4' - 0" 3' - 0" 3' - 0 " 8' - 1 0 1 / 4 " 13 ' - 5 7 / 8 " 4' - 1 0 " CL R 2' - 6 " 8' - 5 " 6' - 0 " 3' - 10 5/8"2' - 8"2' - 8"2' - 8" 5' - 2" 4 4 5 7 7 7 7 4 4 CL R 4' - 0 " 12' - 7" EQ EQ 16'-5" HEAD HEIGHT 23 ' - 2 1 / 2 " 2' - 0" CL R 2' - 6 " 7 7 8' - 8 7/8" 9' - 6 " - --- - --- - --- 1' - 6 " B 5 TOWER ANTENNA ROOM 301 4 B C 5 3' - 1 1/2" 5'-0"CLR 5' - 2" (5' CLR) 5' - 1 1/2"CLR 4' - 10" CLR 4' - 10"4' - 7 3/4"11" 11' - 2 1/8" CLR 2' - 6" 4' - 11 5/8"4' - 9"4' - 2 3/4" 1' - 5 1/8" 11' - 7 1/4" 5' - 8" 5' - 3 1/4" CLR 1' - 7" CLR 1' - 7" WOMEN 114 MEN 113 JAN 1151' - 6" 7' - 0" 3' - 4 1/2" CLR 5' - 0" 1' - 6" 3' - 4 3/8" 12' - 5 5/8" E107E108 7 7 7 5' - 1 3/4" 30' - 8 7/8" 11" 4 B 5 DW RANGE 5' - 1 3/4" 2' - 0 1/4" 2' - 0 1/4" 1' - 2" STORAGE 212 KITCHEN 224 3' - 0" TYPE 1 TYPE 1A - FULL HEIGHT TO BOTTOM OF ROOF STRUCTURE TYPE 2 - INTERIOR DEMISING WALL TO UNDERSIDE OF ROOF STRUCTURE 1 LAYER 5/8" GYPSUM WALL BOARD 2X4 WOOD STUDS @ 16" O. C. WITH SOUND BATTS 1 LAYER 5/8" GYPSUM WALL BOARD 1 LAYER 5/8" GYPSUM WALL BOARD 2X4 WOOD STUDS @ 16" O. C. WITH SOUND BATTS 1 LAYER 5/8" GYPSUM WALL BOARD 2 LAYER 5/8" TYPE X GYPSUM WALL BOARD 2X4 WOOD STUDS @ 16" O. C. WITH SOUND BATTS 2 LAYER 5/8" TYPE X GYPSUM WALL BOARD PROVIDE SLIP TRACK WITH ACOUSTIC ISLOATION AT TOP OF ALL CONNECTIONS TO UNDERSIDE OF STRUCTURE, TYPICAL. PROVIDE SLIP TRACK WITH ACOUSTIC ISLOATION AT TOP OF ALL CONNECTIONS TO UNDERSIDE OF STRUCTURE, TYPICAL. INTERIOR WALL TYPES TYPE 3 2X4 WOOD STUD FURRING @ 16" O. C. 1 LAYER 5/8" GYPSUM WALL BOARD TYPE 4 1 LAYER 5/8" GYPSUM WALL BOARD 2X6 WOOD STUDS @ 16" O. C. WITH SOUND BATTS 1 LAYER 5/8" GYPSUM WALL BOARD TYPE 5 4" CMU - REINFORCED PER STRUCTURAL ACRYLIC ENAMEL PAINT OR TILE PER FINISH SCHEDULE TYPE 6 6" CMU - REINFORCED PER STRUCTURAL ACRYLIC ENAMEL PAINT OR TILE PER FINISH SCHEDULE 1 EXISTING TO REMAIN- FIELD VERIFY ISSUE RECORD 1650 Fallridge Road, Suite C-1 Vail, CO 81657 f.(970) 476-4901 p.(970)476-6342 42 W E S T M E A D O W D R I V E VA I L , C O 8 1 6 5 7 7 ASI 007 13 NOV 2102 A2.2 LEVEL 2 PLAN & ENLARGED PLANS FI R E S T A T I O N # 2 R E N O V A T I O N PR O J E C T # 1 2 0 4 16 JUL 2012 3/16" = 1'-0"1 Level 2 Plan Room Finish Schedule - Level 2 Room NumberRoom NameFloor FinishBase FinishWall FinishCeiling Finish 210NORTH STAIRRUBBER TILERESILIENT BASEPAINT-SEMIGLOSSPAINT-SEMIGLOSS 211MECHANICALSEALED CONCNONE PAINT-SEMIGLOSSPAINT-SEMIGLOSS 212STORAGESEALED CONCNONEPAINT-SEMIGLOSSPAINT-SEMIGLOSS 213POLEVINYL TILERESILIENT BASEPAINT-SEMIGLOSSPAINT-SEMIGLOSS 214HALLCARPETRESILIENT BASEPAINT-SEMIGLOSSPAINT-SEMIGLOSS 215UTILITYVINYL TILERESILIENT BASEPAINT-SEMIGLOSSPAINT-SEMIGLOSS 216TOILETPORCELAIN TILEPORCELAIN TILEPAINT-SEMIGLOSSPAINT-SEMIGLOSS 217TOILETPORCELAIN TILEPORCELAIN TILEPAINT-SEMIGLOSSPAINT-SEMIGLOSS 218STORAGEVINYL TILERESILIENT BASEPAINT-SEMIGLOSSPAINT-SEMIGLOSS 219BEDROOMCARPET-2RESILIENT BASEPAINT-SATINPAINT-SATIN 220BEDROOMCARPET-2RESILIENT BASEPAINT-SATINPAINT-SATIN 221BEDROOMCARPET-2RESILIENT BASEPAINT-SATINPAINT-SATIN 222BEDROOMCARPET-2RESILIENT BASEPAINT-SATINPAINT-SATIN 223HALLVINYL PLANKRESILIENT BASEPAINT-SATINPAINT-SATIN 224KITCHENVINYL PLANKRESILIENT BASEPAINT-SATINPAINT-SATIN 225LIVINGVINYL PLANKRESILIENT BASEPAINT-SATINPAINT-SATIN 226WEST STAIRVINYL PLANKRESILIENT BASEPAINT-SEMIGLOSSPAINT-SEMIGLOSS 227WHITE BOXNONENONEPRIMEPRIME 228TOILETPORCELAIN TILEPORCELAIN TILEPAINT-SEMIGLOSSPAINT-SEMIGLOSS 1/4" = 1'-0"2 Tower Level Plan 1/4" = 1'-0"3 Level 1 Public Restrooms Plan 3/8" = 1'-0"4 Level 2 Duty Kitchen Plan 1 1 1 RATEDWALLULASSEMBLIES U905-1HOUR (8"CMU) U906-1HOUR (6"CMU) U305/U340-1HOUR WHITEBOX/ FUTURETENANTFINISH:R-2 OCCUPANCY FireAssemblies 06DEC2012 Reviewed for Code Compliance Code: 2009 International Building Code (IBC) By Martin Haeberle at 10:55 am, Dec 20, 2012 Level 1 0" Roof 42' - 0" 2 3 Level 2 13' - 4 3/4" 41 5 Level 2.1 14' - 10 1/2" N Landing 1 2' - 10 1/2" North Landing 2 / Storage 8' - 7 1/8" 2 A4.1 7' - 7 7 / 8 " Storage Loft 23' - 1 1/8" 29' - 9 3/4" 5' - 0 1 / 8 " STORAGE MECHANICAL LIVING 225 BEDROOM 220 APPARATUS 124 MEZZANINE STORAGE MEZZANINE STORAGE 7' - 1 0 1 / 4 " 5' - 0 1 / 8 " 13 ' - 9 1 / 4 " 7' - 7 7 / 8 " 3' - 1 0 3 / 8 " 2' - 2 1 / 4 " 10 7 / 8 " Tower Attic Level 36' - 7" 5' - 3 " 3' - 4 1 / 4 " Level 1 0" Level 2 13' - 4 3/4" Landing 1 4' - 6 1/8" BA C Landing 2 9' - 0 1/8" Level 2.1 14' - 10 1/2" North Landing 2 / Storage 8' - 7 1/8" 1 A4.1 1 A4.2 1 A4.3 2 A4.2 WOMEN 114 MEN 113 HALL 123 OFFICE 110 KITCHEN 224 LIVING 225 STORAGE MEZZANINE 13 ' - 9 1 / 4 " Tower Attic Level 36' - 7" Level 1 0" Level 2 13' - 4 3/4" B Level 2.1 14' - 10 1/2" N Landing 1 2' - 10 1/2" North Landing 2 / Storage 8' - 7 1/8" Tower Level 24' - 0" TOWER ANTENNA ROOM 301 MECHANICAL 211 NORTH STAIR 210 ENTRY 120 Tower Attic Level 36' - 7" ISSUE RECORD 1650 Fallridge Road, Suite C-1 Vail, CO 81657 f.(970) 476-4901 p.(970)476-6342 42 W E S T M E A D O W D R I V E VA I L , C O 8 1 6 5 7 A4.1 BUILDING SECTIONS FI R E S T A T I O N # 2 R E N O V A T I O N PR O J E C T # 1 2 0 4 16 JUL 2012 3/16" = 1'-0"1 North-South Section 3/16" = 1'-0"2 West-East Section 3/16" = 1'-0"3 Tower Section at North Stair WHITEBOX/ FUTURETENANTFINISH:R-2 OCCUPANCY IBCITEM21-1.1 or26-1.1FOR 1HOURRATED FLOOR/CEILING RATEDASSEMBLIES ULU305/U340-1HOURWALL FireAssemblies 06DEC2012 Reviewed for Code Compliance Code: 2009 International Building Code (IBC) By Martin Haeberle at 10:55 am, Dec 20, 2012