Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
B12-0611
TOWN OF I L 75 South Frontage Road West Community Development Department Vail, Colorado 81657 970.479.2138 vailgov.com 970.479.2452 fax Certificate of Non-Compliance 02/10/15 Rodney & Susa Wright 1050 Pleasant St. Birmingham,Ml. 48009-2947 Dear Owner/Agent, A certificate of non-compliance is hereby filed in the Town of Vail permanent records for the property located at 1151 Vail View Dr (unit b) with the following action: On 11/27/2012 permit B12-0611 was applied for at this office for exterior remodel. This permit has expired per section 105.5 of the International Building Code 2012 edition. The Town of Vail cannot verify code compliance and the structure has not received a final approval for work authorized. A hold on the approval of any future projects for this property is hereby ordered until the aforementioned permit is resolved with this office. Sincerely, Martin A Haeberle Chief ilding Official r NOTE: THIS PERM/T MUST BE POSTED ON JOBSITE AT ALL TIMES ,. �owr,o�vAU;�. Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657 p. 970.479.2139, f. 970.479.2452, inpsections 970.479.2149 COMBINATION BLDG PERMIT Permit #: B12-0611 Job Address: 1151 VAIL VIEW DR VAIL Location......: UNIT B Parcel No....: 210312101001 OWNER WRIGHT, RODNEY N. & SUSAN A. 11/27/2012 1050 PLEASANT ST BIRMINGHAM MI 48009 APPLICANT SNO-AWAY INC 11/27/2012 Phone: 970-379-4286 ROSS E. DOMBROWSKI PO BOX 4606 BASALT CO 81621 License: C000003579 CONTRACTOR SNO-AWAY INC 11/27/2012 Phone: 970-379-4286 ROSS E. DOMBROWSKI PO BOX 4606 BASALT CO 81621 License: C000003579 Project #: PRJ12-0669 Applied.....: 11 /27/2012 Issued. . . : 12/26/2012 Description: EXTERIOR REMODEL, FRONT DOOR AND STORM DOOR. FRONT DECK, STAIRS, HANDRAIL GUARDRAIL, SKYLIGHT, GARAGE DOOR, STONE ON GARAGE FACE, CHIMNEY AND ENTRY COLUMNS. ALL WORK TO MATCH OTHER SIDE OF DUPLEX. Occupancy: Type Construction: Valuation: $45,000.00 ....................................................,,......,.,,,,,.......,,,.,,....... FEE SUMMARY ,..,,.............,.___.........,.,�.......,.._.,,.._..............,............... Building Permit -- �--------> $593.25 Bldg Plan Check ----------> $385.61 Use Tax Fee-----------------------> $700.00 Electrical Permit ---------> $0.00 Elec Plan Check -----------> $0.00 Restuarant Plan Review--------> $0.00 Mechanical Permit ------> $0.00 Mech Plan Check --------> $0.00 Additional Fees--------------------> $0.00 Plumbing Permit --------> $0.00 Plmb Plan Check ---------> $0.00 Recreation Fee--------------------> $0.00 Investigation-----------------------> $0.00 Will Call------------------------------> $5.00 TOTAL PERMIT FEES--------------> $2,013.86 Payments-------------------------------> $2,013.86 BALANCE DUE------------------------> $0.00 .,..,......,. ........................,..................,....................,....,....,,................,.............,.....,,.,...............,......_,,....................._.....,,,... DECLARATIONS I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the town's zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8:00 AM - 4:00 PM. combination permit_012811 r � # L��� V� !�� 1 . ..•e+xxxxx........�+�x.:..+.e..�..•...:.x..x......w...��x�+xw.ww•w:...,r+..x.•.•w..+...x+.....+.x..r+wxx...x•w.....xx...xx...••.xxw..w..w•xxx.xx....+.+.wwrw.....x.w...,r...x..r...+.+. CONDITIONS OF APPROVAL TO BE MET PRIOR TO FINAL SIGN OFF Permit #: 612-0611 Owner: WRIGHT, RODNEY N. & SUSAN A. UNIT B Address: 1151 VAIL VIEW DR VAIL Location: ..., ........................ �......,..,,,...........»..,,,....,.....,.......,...........................,.,.............,,...,.................,...,,...,....... x,..,.....,.........., Cond: CON0012968 The applicant shall repalce all railings (deck, stairs, and base of stairs) on both sides of the duplex with the new ornamental iron railing. Cond: CON0012969 The appiicant shall install matching garage doors on both units of the duplex. Cond: CON0012970 The app�icant shall install matching stone and cap on the chimneys of both units. Cond: CON0012971 The applicant shall install matching stone and cap on the garage elevation of both units which wraps the east and west elevations and terminates at the inside facade corner under the stairs to both units entries. Cond: CON0012972 The applicant shall install stone and cap on the planter between each unit's garage door which matches the stone and cap to be used on the garage facade and chimneys. This shall be reflected on the plans submitted for building permit. Cond: CON0012973 The applicant shall use the natural stone submitted for both sides of the duplex. The initially submitted synthetic stone is not permitted and cannot be used. combination permit_012811 j � T��UN OF YAIL ' .******.***..**,..********************�****,**,*****�***,*************�**�******************************�************************************.******** REQUIRED INSPECTIONS AND STATUSES Permit #: 612-0611 Owner: WRIGHT, RODNEY N. & SUSAN A. UNIT B Address: 1151 VAIL VIEW DR VAIL Location: ****,..******«„*„****.,*********,.*******«*«*************w*�*****„**********«***,****«****,.*******,�*„***«***««******�.,*****„**********„***«,,,,*««****.,**„ Item: 00030 BLDG-Framing Item: 00010 BLDG-FOOTING Item: 00020 BLDG-Foundation/Steel Item: 00050 BLDG-Insulation Item: 00060 BLDG-Sheetrock Nail Item: 00070 BLDG-Misc. Item: 00542 PLAN-FINAL Item: 00090 BLDG-Final combination permit_012811 *****+**********�*************************************************************************+* TOWN OF VAIL, COLORADOCopy Reprinted on 12-26-2012 at 12:39:56 12/26/2012 Statement *******************************************************************************�************ Statement Number: R120002022 Amount: $1,628.25 12/26/201212:39 PM Payment Method:Credit Crd Init: CG Notation: visa ross dombrowski ----------------------------------------------------------------------------- Permit No: B12-0611 Type: COMBINATION BLDG PERMIT Parcel No: 2103-121-0100-1 Site Address: 1151 VAIL VIEW DR VAIL Location: UNIT B Total Fees: $2,013.86 This Payment: $1,628.25 Total ALL Pmts: $2,013.86 Balance: $0.00 *************************�****************************************************************** ACCOUNT ITEM LIST: Account Code -------------------- BP 00100003111100 PF 00100003112300 UT 11000003106000 wc o0100003112800 Description Current Pmts ------------------------------ ------------ BUILDING PERMIT FEES 593.25 PLAN CHECK FEES 330.00 USE TAX 40 700.00 WILL CALL INSPECTION FEE 5.00 ----------------------------------------------------------------------------- TOWN DF VAIL , _.. � / � � ♦ ` Department of Community Development 75 South Frontage Road Vail, CO 81657 Tel: 970-479-2128 www.vaiigov.com Development Review Coordinator BUILDING PERMIT APPLICATION (Separate applications a�e required for a�arm & sprinkler) Project Street Address: . /ii,s C�SOLq2 �e.�. �fi2� �j (Number) (Street) (Suite #) Building/Complex Name: Contractor Information Business Name: _ S1UU ' JaW �� _�''rt; �, � Business Address: � 0. 130 ��Cv U�v City $/��L-� � Sfate: 'Lo , Zip: , �� ��d Contact Name: � oS5 F. l�c�i,S�2v ws Kr Contact Phone: 5�0 37 9- y�lP ContactE-Mail: Ro55�Do.n&Co�sk,'�C��,�s�:�� I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to c�;r;ply with all Town ordinances and state laws, and to build this structure according to the town's zoning and subdivision codes, design review ap- proved, Inte� national Building and Residential Codes and other ordinances of the Town applicabie thereto. X ���2 �����-' Owner/Owner's Representative Signature (Required) Applicant Information Applicant Name: s�-rr�„s l��p.� Applicant Phone: Applicant E-Mail: Project Information � Owner Name: l�Of� �IZI � � � Parcel #: ,;1 "� �. % �` (For Parcel #, contact Eagle County Assessors Office a4 (9'70-328-8640 or visit www.eaglecounty. us/patie) For Office Llse Only: Fee Paid: � ' `,= �` Received From: Cash Check # CC: Visa / MC Last 4 CC # , Auth # exp date: Project #: � .` ,- � DRB #: --?' - G - �, - � Building Permit #: � �� - ��g 1 ,� Lot #: Block # Subdivision: Work Class: New �j Addition (Oj Aiteration (� Type of Building: Single-Family �j Duplex � Multi-Family �j Commercial (� Other �j r �, Work Type: Interior , �xterior (� Both lO � Electrical Mechanicai Plumbing Building Valuation of Work Included Plans Included Work (QYes �No OYes �No l�f � A �Yes O)No OYes �No /J /�- �Yes OjNo �Yes �No N �� OYes ONo �Yes �No _ Value af all work being performed: $�/�.5" u o 0 r (value based on IBC Section '109.3 & IRC Section 108.3� ,g Electrical Square Footage f�d�f� Detailed Scope and Location of Work: I�L�rza,u+� q-12o1,[.,�� r2oo F s N..,, c ta� , s�..�o ,. �f. s�s, �,4�,,� �, C ��+�r2�� �°/�+ L�, F�o.a�-7� Doc � F2ow.f I�.iZy 9K.Ll..eS!,�f S��,e o� �=C�ow.�' f.w,�,� Go'L��s �n,.��� v�- C��,a�s�.- (use additional sheet if necessary) Date Received: , ;� ��i��`'�J� ,� � �� ,� I jE �� ��� 2 � 2��� ��, � ,_ � J � _ ._: ,� � ��� �� ��r�� �, 12-Ma 2012 OUTSULATION® SMD SYSTEM TM (Formerly SPRINT° MD SYSTEM®) ._ r_ r"%#, .- v, ut .rdu m5mauon ana rinisn System with D OUTSULATION SMD SYSTEM (Formerly SPRINT MD SYSTEM) Specification A^ i�C«+wmv dryvIT "� DS158 Outsulation SMD System (formerly Sprint MD System) Specification DS158 INTRODUCTION This document contains the Manufacturer's Standard Specification for the Outsulation SMD System. These specifications follow the Construction Specification Institute's 3 -part format. TAILORING THE DRYVIT MANUFACTURER'S SPECIFICATIONS TO YOUR PROJECT. These specifications cover the most common ways of using the Outsulation SMD System. Most projects use only a few of the possible combinations of these materials and methods. To tailor the specifications to your Outsulation SMD project, simply use those sections which apply. Also, it may be prudent to place certain parts of the Dryvit Outsulation SMD System Specification in other parts of the project's total specification, such as sealants and framing. The project design professionals are responsible for ensuring that the project specifications are suitable for the project. For assistance in preparing your specification, contact your Dryvit Distributor or Dryvit Systems, Inc. UNITS English Units are included in parentheses after the Standard International (SI) equivalents thus: 12.7 mm (112 in) 16 Kg/m' (1.0 pcf) Please note that the conversions may not be exact but rather represent commonly used equivalents. WARNING The Outsulation SMD System is designed as a drainage wall cladding system and is detailed to discharge incidental moisture from within the System. Specifications should be followed and proper details adhered to, in order to prevent water intrusion, resulting in possible damage to the System or other building elements. Care should be taken to insure that all building envelope elements, including without limitations, roof designs, windows, flashings, sealants, etc., are compatible with this system. DISCLAIMER Information contained in this specification conforms to standard detail and product recommendations for the installation of the Dryvit Outsulation SMD System products as of the date of publication of this document and is presented in good faith. Dryvit Systems, Inc. assumes no liability, expressed or implied, as to the architecture, engineering or workmanship of any project. To insure that you are using the latest, most complete information visit our website at www.dryvit.com, or contact Dryvit Systems, Inc., at One Energy Way P. O. Box 1014 West Warwick, RI 02893 (401) 822 -4100 FAX: (401) 822 -1980 The Trained Contractor Certificate referenced in Section 1.06.A.2 indicates certain employees of the company have been instructed in the proper application of Dryvit products and have received copies of Dryvit's Application Instructions and Specifications. The Trained Contractor Program is not an apprenticeship or endorsement. Each trained contractor is an independent company experienced in the trade and bears responsibility for its own workmanship. Dryvit Systems, Inc. assumes no liability for the workmanship of a trained contractor. Outsulation SMD System (formerly Sprint MD System) Specification DS158 DRYVIT SYSTEMS, INC. ARCHITECTURAL SPECIFICATION SECTION 07240 OUTSULATION SMD SYSTEM AN EXTERIOR INSULATION AND FINISH SYSTEM CLASS PB PART 1 - GENERAL 1.01 SUMMARY A. This document is to be used in preparing specifications for projects utilizing the Dryvit Outsulation SMD System. For complete product description and usage refer to: 1. Dryvit Outsulation SMD Data Sheet, DS441 2. Dryvit Outsulation SMD System Application Instructions, DS123. 3. Dryvit Outsulation SMD System Installation Details, DS163. B. Related Sections 1. Unit Masonry - Section 04200 2. Concrete - Sections 03300 and 03400 3. Light Gauge Cold Formed Steel Framing - Section 05400 4. Wood Framing - Section 06100 5. Sealant - Section 07900 6. Flashing - Section 07600 1.02 REFERENCES A. Section Includes 1. ASTM B 117 (Federal Test Standard 141A Method 6061) Standard Practice for Operating Salt Spray (Fog) Apparatus 2. ASTM C 150 Standard Specification for Portland Cement 3. ASTM C 297 Standard Test Method for Flatwise Tensile Strength of Sandwich Constructions 4. ASTM C 1177 Standard Specification for Glass Mat Gypsum Substrate for Use as Sheathing 5. ASTM C 1396 (formerly C 79) Standard Specification for Gypsum Board 6. ASTM D 968 (Federal Test Standard 141A Method 6191) Standard Test Methods for Abrasion Resistance of Organic Coatings by Falling Abrasive 7. ASTM D 2247 (Federal Test Standard 141A Method 6201) Standard Practice for Testing Water Resistance of Coatings in 100% Relative Humidity 8. ASTM D 2898 Standard Test Method for Accelerated Weathering of Fire - Retardant- Treated Wood for Fire Testing 9. ASTM D 3273 Standard Test Method for Resistance to Growth of Mold on the Surface of Interior Coatings in an Environmental Chamber 10. ASTM D 4060 Standard Test Method for Abrasion Resistance of Organic Coatings by the Taber Abraser 11. ASTM E 84 Standard Test Method for Surface Burning Characteristics of Building Materials 12. ASTM E 96 Standard Test Methods for Water Vapor Transmission of Materials 13. ASTM E 330 Test Method for Structural Performance of Exterior Windows, Doors and Curtain Walls by Uniform Static Air Pressure Difference 14. ASTM E 331 Test Method for Water Penetration of Exterior Windows, Skylights, Doors and Curtain Walls by Uniform Static Air Pressure Difference 15. ASTM E 2098 Test Method for Determining the Tensile Breaking Strength of Glass Fiber Reinforcing Mesh for use in Class PB Exterior Insulation and Finish Systems (EIFS), after Exposure to Sodium Hydroxide Solution. 16. ASTM E 2134 Test Method for Evaluating the Tensile- Adhesion Performance of Exterior Insulation and Finish Systems (EIFS) 17. ASTM E 2273 Test Method for Determining the Drainage Efficiency of Exterior Insulation and Finish Systems (EIFS) Clad Wall Assemblies 18. ASTM E 2430 Standard Specification for Expanded Polystyrene (EPS) Thermal Insulation Boards for use in Exterior Insulation and Finish Systems (EIFS) 19. ASTM E 2485 (formerly EIMA Std. 101.01) Standard Test Method for Freeze -Thaw Resistance of Exterior Insulation and Finish Systems (EIFS) and Water- Resistive Barrier Coatings 20. ASTM E 2486 (formerly EIMA Std. 101.86) Standard Test Method for Impact Resistance of Class PB and PI Exterior Insulation and Finish Systems (EIFS) 21. ASTM G 155 (Federal Test Standard 141A Method 6151) Standard Practice for Operating -Xenon Arc Light Apparatus, for Exposure of Nonmetallic Materials 22. DS123, Dryvit Outsulation SMD System Application Instructions 23. DS131, Dryvit Expanded Polystyrene Insulation Board Specification 24. DS151, Custom Brick' Polymer System Specifications for Use on Vertical Walls 25. DS152, Dryvit Cleaning and Recoating 26. DS153, Dryvit Expansion Joints and Sealants 27. DS159, Dryvit Water Vapor Transmission 28. DS 163, Dryvit Outsulation SMD System Installation Details 29. DS235, Dryvit Homeowner's Maintenance Guide 30, DS494, Dryvit AquaFlashv System 31. Mil Std E5272 Environmental Testing Outsulation SMD System (formerly Sprint MD System) Specification DS158 32. Mil Std 8108 Environmental Test Methods 1.03 DEFINITIONS A. Base Coat: Material used to encapsulate one or more layers of reinforcing mesh fully embedded that is applied to the outside surface of the Polyisocyanu rate insulation board. B. Building Expansion Joint: A joint through the entire building structure designed to accommodate structural movement. C. Contractor: The contractor that installs the Outsulation SMD System to the substrate. D. Dryvit: Dryvit Systems, Inc., the manufacturer of the Outsulation SMD System, a Rhode Island corporation. E. Expansion Joint: A structural discontinuity in the Outsulation SMD System. F. Finish: An acrylic -based coating, available in a variety of textures and colors that is applied over the base coat. G. Insulation Board: Polyisocyan u rate insulation board, which is affixed to the substrate and Expanded Polystyrene used as foam shapes where applicable. H. Mechanical Fasteners: A combination of polypropylene washers and corrosion resistant fasteners used to secure the insulation board to the substrate. I. Reinforcing Mesh: Glass fiber mesh(es) used to reinforce the base coat and to provide impact resistance. J. Sheathing: A substrate in sheet form. K. Substrate: The material to which the Outsulation SMD System is affixed. L. Substrate System: The total wall assembly including the attached substrate to which the Water - Resistive Barrier is affixed. 1.04 SYSTEM DESCRIPTION A. General: The Dryvit Outsulation SMD System is an Exterior Insulation and Finish System (EIFS) Class PB, designed for use on combustible type construction. Outsulation SMD System is installed over a code approved water - resistive barrier and consists of a drainage medium and drainage accessories, an approved Polyisocyanurate insulation board, mechanical fasteners, base coat with reinforcing mesh and finish. B. Acceptable system configuration options include: System Co_nfi uration 1 2 Water - Resistive Barrier Backstop NT or Sheet membrane Tyvek StuccoWra�_ Drainage Medium Drainage Mat or D it MD S acerTM N/A Polyisocyanurate Minimum Thickness 15.9 mm (5/8 in) 15.9 mm (5/8 in) _ Attachment Mechanical Fasteners Mechanical Fasteners Base Coat GenesisO or GenesisO DM Genesis or Genesis DM C. Design Requirements 1. Acceptable substrates for the Outsulation SMD System shall be: a. APA Exterior or Exposure 1 rated Plywood, Grade C -D or better, nominal 12.7 mm (1/2 in), minimum 4 -ply. b. APA Exposure 1 rated Oriented Strand Board (OSB), nominal 12.7 mm (112 in). c. Unglazed brick, cement plaster, concrete or masonry (water- resistive barrier not required). d. Exterior sheathing having a water- resistant core with fiberglass mat facers meeting ASTM C 1177. e. Exterior grade gypsum sheathing meeting ASTM C 1396 (formerly C 79) requirements for water resistant core or Type X core at the time of application of the Outsulation SMD System. f. Exterior grade fire retardant treated plywood. 2. Deflection of substrate systems shall not exceed 1/240 times the span. 3. The substrate shall be flat within 6.4 mm (1/4 in) in a 1.2 m (4 ft) radius. 4. The slope of inclined surfaces shall not be less than 6:12. The length of inclined surfaces shall not exceed 305 mm (12 in). 5. At horizontal sealant joints and windowsills projecting 102 mm (4 in) or less, the slope shall not be less than 3:12. 6. All areas requiring an impact resistance classification higher than "standard ", as defined by ASTM E 2486 (formerly EIMA Standard 101.86), shall be as detailed in the drawings and described in the contract documents. Refer to Section 1.04.D.t.a.4) of this specification. 7. Expansion joints a. Design and location of expansion joints in the Outsulation SMD System is the responsibility of the project designer and shall be noted on the project drawings. As a minimum, expansion joints shall be placed at the following locations: 1) Where expansion joints occur in the substrate system. 2) Where building expansion joints occur. 3) At floor lines in wood frame construction. 4) At floor lines of non -wood frame buildings where significant movement is expected. 5) Where the Outsulation SMD System abuts dissimilar materials. 6) Where the substrate type changes. 7) In continuous elevations at intervals not exceeding 23 m (75 ft). 8) Where significant structural movement occurs such as changes in roofline, building shape or structural system. Outsulation SMD System (formerly Sprint MD System) Specification DS158 8. Terminations a. Prior to applying the Dryvit Outsulation SMD System, wall openings shall be wrapped with Dryvit AquaFlash System or Flashing Tape. Refer to Dryvit Outsulation SMD System Installation Details, DS163. b. The Outsulation SMD System shall be held back from adjoining materials around openings and penetrations such as windows, doors and mechanical equipment a minimum of 12.7 mm (1/2 in) for sealant application. See Dryvit's Outsulation SMD System Installation Details, DS163, for exceptions and alternate methods. c. At the base of walls, the Outsulation SMD System shall extend a minimum of 25 mm (1 in) below the sill plate onto the foundation and be terminated a minimum of 203 mm (8 in) above finished grade. d. For slab -on- grade, the Outsulation SMD System shall extend a minimum of 25 mm (1 in) onto the slab edge. e. Sealants 1) Shall be manufactured and supplied by others. 2) Shall be compatible with the Outsulation SMD System materials. Refer to current Dryvit publication DS153 for listing of sealants tested by sealant manufacturer for compatibility. 3) The sealant backer rod shall be closed cell. 9. Vapor Retarders - The use and location of vapor retarders within a wall assembly is the responsibility of the project designer and shall comply with local building code requirements. The type and location shall be noted on the project drawings and specifications. Vapor retarders may be inappropriate in certain climates and can result in condensation within the wall assembly. Refer to Dryvit Publication DS 159 for additional information. 10. Dark Colors - The use of dark colors must be considered in relation to wall surface temperature as a function of local climatic conditions. Use of dark colors in high temperature climates can affect the performance of the system. 11. Flashing: Flashing shall be provided at all roof -wall intersections, windows, doors, chimneys, decks, balconies and other areas as necessary to prevent water from getting behind the Outsulation SMD System. ). Performance Requirements 1. The Outsulation SMD System shall have been tested as follows: a. Durability 1) Air/Water- Resistive Barrier Coating TEST TEST METHOD _ CRITERIA RESULTS Tensile Bond ASTM C 2971E 2134 _ Minimum 104 kPa (15 psi) Substrate: Minimum 131 kPa ICC ES AC 212)' 11.9 P_- )_ Freeze Thaw ASTM E 24851ICC ES Proc. No deleterious effects after 10 cycles -- Passed — No deleterious AC 212)' effects after 10 cycles Water Resistance ASTM D 2247 No deleterious effects after 14 days No deleterious effects after ICC ES AC 212)' exposure 14 days ex osure Water Vapor ASTM E 96 Proc. B Vapor Permeable -- 7 perms Transmission ICC ES (AC 212)' Air Leakage ASTM E 283 No Criteria Less than 0.6 I/min /m (0.002 cfm/ft2 Structural ASTM E 1233 Proc. A _ Minimum 10 positive cycles at 1/240 Passed Performance ICC ES (AC 212)' deflection; No cracking in field, at joints or interface with flashing_ Racking ASTM E 72 No cracking in field, at joints or interface with Passed ICC ES (AC 212)' flashing at net deflection of 3.2 mm 1/8 in Restrained ICC ES (AC 212)' 5 cycles; no cracking in field, at joints or Passed Environmental interface with flashing Water Penetration ASTM E 331 No water penetration beyond the inner -most Passed ICC ES (AC 212)` plane of the wall after 15 minutes at 137 Pa 2.86 sf Weathering ICC ES Proc. 210 hours of exposure - -.... -- passed LIV Exposure ICC ES (AC 212)' Accelerated ICC ES Proc. 25 cycles of drying and soaking Passed Aging ICC ES (AC 212)' Hydrostatic AATCC 127 21.6" water column for 5 hours Passed Pressure Test ICC ES (AC 212) Surface Burning ASTM E 84 Flame Spread < 25 Passed Characteristics Smoke Developed < 450 ' AC 212 — Acceptance Criteria for Water - Resistive Coatings Used as Water - Resistive Barriers Over Exterior Outsulation SMD System (formerly Sprint MD System) Specification DS158 2) System TEST TEST METHOD CRITERIA RESULTS Abrasion Resistance ASTM D 968 No deleterious effects after No deleterious effects after _ . (5()-89) 500 liters J528 quarts) 1000 liters 1056 quarts) Accelerated Weathering ASTM G 155 Cycle 1 No deleterious effects after No deleterious effects after 90-150 12 2000 hours 5000 hours 71 ghcm 400 Ibs/in) ASTM G 154 Cycle 1 (QUV) No deleterious effects after >150 18 162 5000 hours Freeze -Thaw ASTM E 2485 (formerly No deleterious effects after Passed - No deleterious 40 EIMA 101.0 -1) 60 cycles effects after 90_cycles n/a ASTM C 67 modified No deleterious effects after Passed - No deleterious n/a Comer Mesh TM - 244 7.2 60 cycles effects after 60 cycles n/a ASTM E 2485 /ICC -ES Proc. No deleterious effects after Passed - No deleterious *Shall be used in conjunction with Standard Mesh (recommended for areas exposed to high traffic AC235 ''* 10 c les_ effects after 10 cycles Mildew Resistance ASTM D 3273 No growth during 28 day No growth during 60 day exposure period No deleterious effects after exposure period No deleterious effects after Water Resistance ASTM D 2247 14 days exposure 42 des exposure Taber Abrasion ASTM D 4060_ N/A Passed 1000 cycles Salt Spray Resistance ASTM B 117 No deleterious effects after No deleterious effects after 300 hours exposure 1000 hours exposure Water Penetration ASTM E 331 No water penetration beyond Passed 15 minutes at ICC ES (AC 235)*'* the inner -most plane of the 137 Pa (2.86 psf) wall after 15 minutes at 137 Pa (2.86 sfO Water Vapor ASTM E 96 Vapor permeable Quik -R 1.7 perm -inch Transmission Base Coat* 40 Perms Finish" 40 Perms Drainage Efficiency ASTM E 2273 Minimum Drainage Efficiency Passed ICC ES AC 235)*** of 90% Base Coat * perm value based on D pe ryvit Genesis " Finish perm value based on Dryvit Quarzputz *" AC 235 — Acceptance Criteria for EIFS Clad Drainage Wall Assemblies 3) Structural TEST TEST METHOD CRITERIA RESULTS Tensile Bond ASTM C 297/E 2134 Minimum 104 kPa (15 psi) — Minimum 213.6 kPa (31 psi) 6-10 (5()-89) insulation failure 56 Trans a Wind Load ASTM E 330 Withstand positive and negative Minimum 4.3 kPa (90 psf) 90-150 12 wind loads as specified by the Panzer 15 - 509 15) 71 ghcm 400 Ibs/in) Ultra High builder code >150 4) Impact Resistance: In accordance with ASTM E 2486 (formerly EIMA Standard 101.86). Reinforcing Mesh/Weight g /m' (oz/yd') Standard - 146 4.3 Minimum Tensile Strengths 27 cm 150 lbs/in EIMA Impact Classification Standard EIMA Impact Range Joules (in4bs) 3-6 25-49 Impact Test Results Joules in4bs 4 36 Standard Plus - 203 6 36 g1cm 200 lbs/in Medium 6-10 (5()-89) 6 56 Intermediate Mesh - - 407 12 54 /cm 300 Ibs/in High 10 -17 90-150 12 108 Panzer 15 - 509 15) 71 ghcm 400 Ibs/in) Ultra High >17 >150 18 162 Panzer 20 * 695 20.5 98 /cm 550 Ibsfin Ultra Hi h >17 >150 40 352 Detail Mesh`s Short Rolls - 146 4.3 27 g/cm (1501bsfin) n/a n/a n/a n/a n/a Comer Mesh TM - 244 7.2 49 /cm 274 Ibs/in n/a n/a n/a n/a__ n/a *Shall be used in conjunction with Standard Mesh (recommended for areas exposed to high traffic Outsulation SMD System (formerly Sprint MD System) Specification DS158 2. The Outsulation SMD Components shall have been tested for: a. Durability TEST TEST METHOD - -- CRITERIA RESULTS Reinforcing Mesh —____._-------- - -- Alkali Resistance of ASTM E 2098 (formerly > 21dN /cm (120 pli) retained Passed Reinforcing Mesh EIMA 105.01) tensile strength after exposure Polyisocyanurate (Physical Properties) Density ASTM D 1622 32 kg/m' (2.0 lb/ft') Pass Thermal Resistance ASTM C 177, C 518 5.6 @ 23.9 °C (75 °F) Pass Water Absorption ASTM C 272 2.55 % max, by volume Pass Compressive Strength ASTM D 1621 179 kPa (26 psi) min. Pass Flexural Strength ASTM C 203 814 kPa (118 psi) min. Pass Flame Spread ASTM E 84 25 max. Pass Smoke Developed 450 max. Pass 1.05 SUBMITTALS A. Product Data – The contractor shall submit to the owner /architect the manufacturer's product data sheets describing products, which will be used on this project. B. Samples: The contractor shall submit to the owner /architect two (2) samples of the Outsulation SMD System for each finish, texture and color to be used on the project. The same tools and techniques proposed for the actual installation shall be used. Samples shall be of sufficient size to accurately represent each color and texture being utilized on the project. C. Test Reports – When requested, the contractor shall submit to the owner /architect copies of selected test reports verifying the performance of the Outsulation SMD System. 1.06 QUALITY ASSURANCE A. Qualifications: 1. System Manufacturer: Shall be Dryvit Systems, Inc. All materials shall be manufactured or sold by Dryvit and shall be purchased from Dryvit or its authorized distributors. a. Materials shall be manufactured at a facility covered by a current ISO 9001:2000 and ISO 14001:2004 certification. Certification of the facility shall be done by a registrar accredited by the American National Standards Institute, Registrar Accreditation Board (ANSI -RAB). 2. Contractor: Shall be knowledgeable in the proper installation of the Dryvit Outsulation SMD System and shall be experienced and competent in the installation of Exterior Insulation and Finish Systems. Additionally, the contractor shall possess a current Outsulation SMD System Trained Contractor Certificate', issued by Dryvit Systems, Inc. 3. Insulation Board Manufacturer: Shall be Dow Chemical Corporation for Quik -RI Wall Insulation or Atlas Roofing Corporation for Atlas Stucco- ShieldQ. B. Regulatory Requirements: 1. The insulation board shall be separated from the interior of the building by a minimum 15- minute thermal barrier. 2. The use and maximum thickness of insulation shall be in accordance with the applicable building codes. C. Certification 1. The Outsulation SMD System shall be recognized for the intended use by the applicable building code(s). D. Mock -Up 1. The contractor shall, before the project commences, provide the owner /architect with a mock -up for approval. 2. The mock -up shall be of suitable size as required to accurately represent the products being installed, as well as each color and texture to be utilized on the project. 3. The mock -up shall be prepared with the same products, tools, equipment and techniques required for the actual applications. The finish used shall be from the same batch that is being used on the project. 4. The approved mock -up shall be available and maintained at the job site. 1.07 DELIVERY, STORAGE AND HANDLING A. All Dryvit materials shall be delivered to the job site in the original, unopened packages with labels intact. B. Upon arrival, materials shall be inspected for physical damage, freezing or overheating. Questionable materials shall not be used. 1. Materials shall be stored at the jobsite in a cool, dry location, out of direct sunlight, protected from weather and other sources of damage. Minimum storage temperature shall be as follows: a. Demandito, Revyvite: 7° C (45" F) b- AmeristoneTM, TerraNeo'g' and LymestoneT"': 10 °C (50 °F) c DPR, PMRT", E FinishesT", Color Prime TM and Genesis 4 °C (40 °F) d. Custom Brick Finish: Refer to Custom Brick Polymer Specification, DS151 e. For other products, refer to specific product data sheets 2. Maximum storage temperature shall not exceed 38 °C (100 `F). NOTE: Minimize exposure of materials to temperatures over 32 °C (90 °F). Finishes exposed to temperatures over 43 °C (110 °F) for even short periods may exhibit skinning, increased viscosity and should be inspected prior to use. Outsulation SMD System (formerly Sprint MD System) Specification DS158 C. Protect all products from inclement weather and direct sunlight. 1.08 PROJECT CONDITIONS A. Environmental Requirements 1. Application of wet materials shall not take place during inclement weather unless appropriate protection is provided. Protect materials from inclement weather until they are completely dry. 2. At the time of application, the minimum air and wall surface temperatures shall be as follows: a. Demandit, Revyvit: 7 °C (45 °F) b. Ameristone, TerraNeo and Lymestone: 10 °C (50 °F) c. DPR, PMR, E Finishes, Color Prime and Genesis: 4 °C (40 °F) d. Custom Brick Finish: refer to Custom Brick Polymer Specification, DS 151 e. For other products, refer to specific product data sheets 3. These temperatures shall be maintained with adequate air ventilation and circulation for a minimum of 24 hours (48 hours for Ameristone, TerraNeo and Lymestone) thereafter, or until the products are completely dry. Refer to published product data sheets for more specific information. B. Existing Conditions - The contractor shall have access to electric power, clean water, and a clean work area at the location where the Dryvit materials are to be applied. 1.09 SEQUENCING AND SCHEDULING A. Installation of the Outsulation SMD System shall be coordinated with other construction trades. B. Sufficient manpower and equipment shall be employed to ensure a continuous operation, free of cold joints, scaffold lines, texture variations, etc. 1.10 WARRANTY A. Dryvit Systems, Inc. shall provide a written limited moisture drainage warranty combined with a written limited materials warranty against defective material upon written request. Dryvit shall make no other warranties, expressed or implied. Dryvit does not warrant workmanship. Full details are available from Dryvit Systems. Inc. B. The applicator shall warrant workmanship separately. Dryvit shall not be responsible for workmanship associated with installation of the Outsulation SMD System. 1.11 DESIGN RESPONSIBILITY A. It is the responsibility of both the specifier and the purchaser to determine if a product is suitable for their intended use. The designer selected by the purchaser shall be responsible for all decisions pertaining to design, detail, structural capability, attachment details, shop drawings and the like. Dryvit has prepared guidelines in the form of specifications, application details, and product data sheets to facilitate the design process only. Dryvit is not liable for any errors or omissions in design, detail, structural capability, attachment details, shop drawings, or the like, whether based upon the information prepared by Dryvit or otherwise, or for any changes which purchasers, specifiers, designers, or their appointed representatives may make to Dryvit's published comments. 1.12 MAINTENANCE A. Maintenance shall follow the procedures noted in the Dryvit Homeowner's Maintenance Guide, DS235, and repair shall follow the procedures noted in the Dryvit Outsulation SMD System Application Instructions, DS 123. B. All Dryvit products are designed to require minimal maintenance. However, as with all building products, depending on location, some cleaning may be required. See Dryvit publication DS152 on Cleaning and Recoating. C. Sealants and Flashings shall be inspected on a regular basis and repairs made as necessary. PARTII- PRODUCTS 2.01 MANUFACTURER A. All components of the Outsulation SMD System shall be supplied or obtained from Dryvit or its authorized distributors. Substitutions or additions of materials other than specified will void the warranty. 2.02 MATERIALS A. Portland Cement: Shall be Type I or 11, meeting ASTM C 150, white or gray in color, fresh and free of lumps. B. Water: Shall be clean and free of foreign matter. 2.03 COMPONENTS A. Air/Water- Resistive Barrier Components. 1. Water- Resistive Barrier Coating a. Dryvit Backstop NT: A flexible, polymer- based, noncementitious water - resistive coating available in Texture and Smooth. b. Dryvit Grid Tape I: An open weave fiberglass mesh tape with pressure sensitive adhesive available in rolls 102 mm (4 in) wide by 91 m (100 yd) long. 2. Sheet Type Membranes (by others) a. Code approved water- resistive barrier such as but not limited to Dupont Tyvek StuccoWrap, Tyvek Home Wrap or Commercial Wrap, #15 Felt, Grade D Paper, B. Flashing Materials: Used to protect substrate edges at terminations. 1. Liquid Applied: An extremely flexible water -based polymer material, ready for use. a. Shall be AquaFlash and AquaFlash Mesh Outsulation SMD System (formerly Sprint MD System) Specification DS158 2. Sheet Type: a. Shall be Flashing Tape and Surface Conditioner 1) Dryvit Flashing Tape 11: A high density polyethylene film backed with a rubberized asphalt adhesive available in rolls 102 mm (4 in), 152 mm (6 in) and 229 mm (9 in) wide by 23 m (75 ft) long. 2) Dryvit Flashing Tape Surface Conditioner TM: A water -based surface conditioner and adhesion promoter for the Dryvit Flashing Tape. C. Dryvit AP Adhesives": A moisture cure, urethane based adhesive used to adhere the Dryvit Drainage Strip and Drainage Track D. Accessories 1. Drainage Track (Optional - not required when Drainage Strip is specified): UV treated PVC perforated "J" channel with weep holes, complying with ASTM D 1784 and ASTM C 1063. Shall be one of the following: a. Starter Trac STWP - without drip edge by Plastic Components, Inc. b. Starter Trac STDE - with drip edge by Plastic Components, Inc. c. Universal Starter Track by Wind -lock Corporation d. Sloped Starter Strip with Drip by Vinyl Corp. 2. Dryvit Drainage Strips*" (Optional - not required when Drainage Track is specified): A corrugated plastic material, which provides drainage. Required when using Tyvek StuccoWrap without the Drainage Track. E. Drainage Medium Options 1. Dryvit Drainage Mat [System 1 (optional when Outsulation SMD System is installed over Tyvek StuccoWrap)]: A blue, 3.2 mm (1/8 in) thick mat composed of open weave polymer threads. 2. Dryvit MD Spacer (optional when installed over Tyvek StuccoWrap): A 3.2 mm (1/8 in) thick polyethylene spacer, which separates the insulation board from the substrate F. Insulation Board: Quik -R Wall Insulation or Atlas Stucco Shield. 1. Thickness of insulation board shall be minimum 15.9 mm (5/8 in). 2. The insulation board shall be manufactured by Dow Chemical Corporation or Atlas Roofing Corporation. G. Mechanical Fasteners consist of a 44 mm (1 '/. in) diameter polypropylene plastic plate (washer) with key openings for base coat penetration used in conjunction with a corrosion resistant fastener. 1. Washer a. Shall be Wind -Lock ULP 302 or 402 Plate, or ITW Buildex Grid - Mate''" washer or Grid -Mate with stem. 2. Screws, Nails, Anchors a. Wood /Steel Framing with a nailable substrate (Plywood or Oriented Strand Board). 1) Shall be minimum No. 6, bugle head corrosion resistant screws. 2) The screws shall be of sufficient length to penetrate the wood substrate a minimum of 19 mm (3/4 in). 3) Nails shall be minimum 12 gauge (8d), ring shank. They shall be hot dipped galvanized and of sufficient length to penetrate the structural base a minimum of 25 mm (1 in). Ring shank nails are not recommended for attachment to Oriented Strand Board. b. Wood /Steel Framing with a non - structural substrate (gypsum based or similar) 1) Wood Screws shall be a minimum No. 6, bugle head, corrosion resistant screws and of sufficient length to penetrate the wood framing a minimum of 19 rnm (3/4 in). 2) Light Gauge Metal Framing (minimum 20 gauge) requires minimum No. 6, self drilling corrosion resistant screws and shall be of sufficient length to penetrate the steel framing a minimum of 9.5 mm (3/8 in). 3) Nails shall be ring shank and a minimum of 12 gauge (8d). They shall be hot dipped galvanized and of sufficient length to penetrate the wood framing a minimum of 25 mm (1 in). c. Concrete /Masonry 1) Anchors shall be a minimum 4.8 mm (3/16 in) diameter and corrosion resistant. 2) Anchors shall be of sufficient length to penetrate the substrate a minimum of 25 mm (1 in). 3) Pullout values shall be substantiated for the particular substrate and fastener. H. Insulation Board used for Foam Shapes (where specified): Expanded Polystyrene meeting the Dryvit Specification for Insulation Board, DS131, and the following requirements: 1. The insulation board shall be manufactured by a board supplier listed by Dryvit Systems, Inc. I. Base Coat: Shall be compatible with the insulation board and reinforcing mesh. 1. Cementitious: A liquid polymer -based material, which is field mixed with Portland cement. a. Shall be Genesis 2. Ready mixed: A dry blend cementitious, copolymer -based product, field mixed with water. a. Shall be Genesis® DM J. Reinforcing Mesh. A balanced, open weave, glass fiber fabric treated for compatibility with other system materials. NOTE: Reinforcing meshes are classified by impact resistance and specified by weight and tensile strength as listed in Section 1.04.D.1.a.4). K. Finish: Shall be the type, color and texture as selected by the architect/owner and shall be one or more of the following: 1. Standard DPR (Dirt Pickup Resistance): Water - based, acrylic finish with integral color and texture and formulated with DPR chemistry: a. Quarzputz0 DPR: Open - texture pattern. b. Sandblast' DPR: Medium texture. c. Freestyle' DPR: Fine texture. 9 Outsulation SMD System (formerly Sprint MD System) Specification DS158 d. SandpebbW' DPR: Pebble texture. e. Sandpebble* Fine DPR: Fine pebble texture. 2. E: Water - based, lightweight acrylic finish with integral color and texture and formulated with DPR chemistry: a. Quarzputzo E b. Sandpebbleg' E c. Sandpebble Fine E 3. Specialty: Factory mixed, water -based acrylic a. Ameristone: Multi- colored quartz aggregate with a flamed granite appearance. b. Stone Mist ®: Ceramically colored quartz aggregate. c. Custom Brick Finish: Acrylic polymer -based finish used in conjunction with a proprietary template system to create the look of stone, brick, slate or tile. d. TerraNeo�: 100% acrylic -based finish with large mica chips and multi - colored quartz aggregates. e. LymestoneTM" A premixed, 100% acrylic -based finish designed to replicate the appearance of limestone blocks. 4. Elastomeric DPR (Dirt Pickup Resistance): Water - based, elastomeric acrylic finish with integral color and texture, and formulated with DPR chemistry: a. Weatherlastic Quarzputz b. Weatheriastie Sandpebble c. Weatherlastie Sandpebble Fine d. Weatherlastie Adobe 5. Medallion Series PMR (Proven Mildew Resistance): Water - based. acrylic finish with integral color and texture and formulated with PMR chemistry: a. Quarzputzq' PMR b. Sandblast"' PMR c. Freestyle PMR d. SandpebblePMR e. Sandpebbles Fine PMR 6. Coatings, Primers and Sealers: a. Demandit b. Weatherlastie Smooth c. Tuscan Glazer d. Revyvit e. Color Prime f. Prymit$ g. SealClear PART III - EXECUTION 3.01 EXAMINATION A. Prior to installation of the Outsulation SMD System, the contractor shall verify that the substrate: 1. Is of a type listed in Section 1.04 C.1. 2. Is flat within 6.4 mm (1/4 in) in a 1.2 m (4 ft) radius. 3. Is sound, dry, clean, free of efflorescence, connections are tight, has no surface voids, projections, or other conditions that may interfere with the Outsulation SMD System installation or performance. B. Prior to installation of the Outsulation SMD System, the architect or general contractor shall ensure that all needed flashings and other waterproofing details have been completed, if such completion is required prior to the Outsulation SMD System application. Additionally the contractor shall ensure that: 1. Metal roof flashing has been installed in accordance with Asphalt Roofing Manufacturers Association (ARMA) Standards and Dryvit Outsulation SMD System Installation Details, DS163, or as otherwise necessary. 2. Openings are flashed in accordance with the Outsulation SMD System Installation Details, DS163, or as otherwise necessary to prevent water penetration. 3. Chimneys, Balconies, and Decks have been properly flashed. 4. Windows, Doors, etc. are installed and flashed per manufacturer's requirements and the Outsulation SMD System Installation Details, DS163. riers have been installed in a weatherboard fashion in accordance with 5. Sheet type membrane water- resistive bar building code and manufacturer's requirements. C. Prior to the installation of the Outsulation SMD System, the contractor shall notify the general contractor and/or architect and/or owner of all discrepancies. 3.02 PREPARATION A. The Dryvit Outsulation SMD System materials shall be protected by permanent or temporary means from inclemen weather and other sources of damage prior to, during, and following application until completely dry. B. Protect adjoining work and property during Outsulation SMD System installation. C. When Dryvit Backstop NT is specified as the water- resistive barrier, the substrate shall be prepared as to be free of foreign materials such as oil, dust, dirt, form release agents, efflorescence, paint, wax, water repellants, moisture, frost, and any other condition that may inhibit adhesion. HM Outsulation SMD System (formerly Sprint MD System) Specification DS158 3.03 INSTALLATION A. The system shall be installed in accordance with the Dryvit Outsulation SMD System Application Instructions, DS123. B. The overall minimum base coat thickness shall be sufficient to fully embed the mesh. The recommended method is to apply the base coat in two (2) passes. C. Sealant shall not be applied to textured finishes or base coat surfaces. Dryvit Outsulation SMD System surfaces in contact with sealant shall be coated with Demandit or Color Prime. D. High impact meshes shall be installed as specified at ground level, high traffic areas and other areas exposed to or susceptible to impact damage. 3.04 FIELD QUALITY CONTROL A. The contractor shall be responsible for the proper application of the Outsulation SMD System materials. B. Dryvit assumes no responsibility for on -site inspections or application of its products. C. If required, the contractor shall certify in writing the quality of work performed relative to the substrate system, details, installation procedures, workmanship and the specific products used. D. If required, the sealant contractor shall certify in writing that the sealant application is in accordance with the sealant manufacturer's and Dryvit's recommendations. 3.05 CLEANING A. All excess Outsulation SMD System materials shall be removed from the job site by the contractor in accordance with contract provisions and as required by applicable law. B. All surrounding areas, where the Dryvit Outsulation SMD System has been applied, shall be left free of debris and foreign substances resulting from the contractor's work. 3.06 PROTECTION A. The Outsulation SMD System shall be protected from inclement weather and other sources of damage until dry and permanent protection in the form of flashings, sealants, etc. are installed. Dryvit Systems, Inc. P.O. Box 1014 One Energy Way West Warwick, RI 02893 800 -556 -7752 www.dryvit.com Printed m USA R12:02 -10.09 11 VD'"t systertis, Inc 19% dryvi` OSMD 0.0.01 rf -:.rl �r �- — WOOD OR STEEL FRAMING — SUBSTRATE CODE C' CODE APPROVED WATER - RESISTIVE BARRIER 1, DRYVIT MO SPACER" �; T ORYVIT APPROVED WASHER WITH fy ? CORROSION RESISTANT FASTENER -- APPROVED OSMO SYSTEM INSULATION BOARD DRYVIT GENESIS ®, GENESIS OM OR GENESIS DMS BASE COAT 'IT REINFORCING MESH 'IT GENESIS, GENESIS OM ENESIS DMS BASE COAT 'IT FINISH 4AGE STRIP DRYVIT DETAIL 9 51 MM (2 ") MIN. tCKSIDE OF INSULATION BOARD Drainage Track Option Outsulation®SMD System TM Outsulation SMD System M'PROVED By REV DATE is a 41109 The ar<twfe,we, engneenng ar,d de.W. cM the prop, uSmg Th. Dryvlt pr.fu,ts rs d+a ro'spor,s�IrGiy <A tt.e prop,'s design profos —al. A9 "Stoma must c�y with Ioral twiding C 0 :ud 1W .Jails. This detail w f x yemrral .tor b— arrd yualaru:e or4y aril Dryvrt sPec0_4y dfscial -S any katAty for U. use of Nis dotaii rv"A (ur ihf, xrchite,u dp. gn, fmgr.farmg or workmrunY w of any 4vol�v;t_ The pr7" d.r>wgr, WafosSiural de4_ -S rn NS bole d C',nC—, wtWther th, d.Od Cd 8 furn .#y erqury Nanl AltenWlYV@ i5 tN'!81 JUit d fpr o" P_4 . Llge of a k6. y oqj ..Alertt dl,.lJd dcros rwt _Al le DryM's warantY. 1 his delarl A A4,,A to Tanga WO-4 nou Contact DlyW [o,ni 0 you haw the must rent dr Y vl � Outsulation® SMD System TM (formerly Sprint MD System®) Exterior Claddinq With Moisture Drainaae Stopping Moisture in its Tracks For residential and light commercial construction, the Dryvit Outsulation SMD System offers outstanding insulating qualities and versatile beauty with an extra level of moisture protection. The drainage plane installed between the water- resistive barrier and the insulation board creates a drainage channel to weep incidental water to the exterior. DS441 Engineered for Moisture Drainage The system's insulation board is mechanically fastened over a code - approved water - resistive barrier over plywood or OSB substrate with Dryvit's approved fasteners, which provide maximum wind load performance. The drainage plane creates a path, which allows for a quick exit of incidental moisture. A Transferable 10 -Year Drainage and Materials Warranty - -An Industry First The Outsulation SMD System is backed by an unprecedented ten -year moisture drainage and materials warranty — an industry first. This unique assurance gives you an added level of confidence. The system is warranted to effectively drain any moisture that enters the wall between the insulation board and the water - resistive barrier. This innovative warranty also has another important benefit: it is transferable from the builder to the owner, and subsequent owners, during the covered ten -year period. Fast Installation, Perfect for Remodeling The system's large dimension insulation board (4 ft x 8 ft) reduces the total number of joints and promotes faster and easier installation, Dryvit Energy Efficiency, Durability and Beauty The Outsulation SMD System maintains the tradition of Dryvit's leadership in design flexibility, thermal efficiency (R -value 5.6 per inch thickness), impact resistance and superior finishes with proven resistance to dirt and mildew accumulation. All Dryvit finishes, in their wide variety of colors and textures, can be applied to the Outsulation SMD System. Dryvit finishes, as with all other exteriors, are designed to require normal maintenance (refer to Dryvit's Homeowner's Maintenance Guide, DS235, or the Cleaning and Recoating data sheet, DS 152). Dryvit Systems, Inc. One Energy Way P.O. Box 1014 West Warwick, RI 02893 800 -556 -7752 www.dryvit.com Printed in USA R401 -13-09 ecX yvrt Systems. Inc. 1998 Information contained in this information page conforms to the standard detail recommendations and specifications for the installation of Dryvit Systems, Inc.. products as of the date of publication of this document and is presented in good faith. Dryvit Systems, Inc. assumes no liability, expressed or implied, as to the architecture, engineering or workmanship of any project. To ensure that you are using the latest, most complete information, contact Dryvit Systems, Inc. dryer '1' TOWN OF VAII Department of Community Development 75 South Frontage Road Vail, CO 81657 Tel: 970.479.2128 www.vailgov.com Development Review Coordinator TRANSMITTAL FORM Use this form when submitting additional information for planning applications or building permits. This form is also used for requesting a revision to building permits. A two hour minimum building review fee of $110 will be charged upon reissuance of the permit. Application /Permit #(s) information applies to: 21a - o (0 l I PRS «- o (oI✓9 Project Street Address: 1175- s o (44 7)a ( M oflJC i3 (Number) (Street) (Suite #) Building /Complex Name: Applicant Information (architect, contractor, owner /owner's rep) 5,ub- fJW(} y Contact Name: �v SS �. �p01S�a�S�L. Address:: PO ��//&C* City �' State: C 0 Zip: 61(";Q ;Q /- ` Contact Name: SS Contact Phone: Attention 2 ContactE -Mail: (dSSe �mb�owSk.� c0k"C4�•Owa I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the town's zoning and subdivision codes, design review ap- proved, International Building and Residential Codes and other oVan s of the Town applicable thereto. X -. Owner /Owner's Representative Signature (Required) For Office Use Only: Fee Paid: Received From: Cash CC: Visa / MC Last 4 CC # Authorization # Check # exp. date: 0 Revisions 0 Response to Correction Letter j3_attached copy of correction letter 0 Deferred Submittal Q Other Description of Transmittal/ List of Changes, Items Attached: sfA-1t2 rz,t t�a�L ° Vt"- ski r /f t yw ut o . (use additional sheet if necessary) Building Permits: Revised ADDITIONAL Valuations (Labor & Materials) (DO NOT include original valuation) Building: $ Plumbing: $ Electrical: $ Mechanical: $ Total: $ 0 Date Received: nr DEC 0 5 2012 U TOWN OF_. U�`- Rods and Controls Rods 6' -10' manual ZCT 300 ZST 300 (ZST 300 is only for pleated shade for curb mounted skylight) ZMT 300 6' -10' motorized $137 ZCT 100 3' extension Electrical controls: The VSE is pre- equipped with a control system for two electrical blinds, but additional controls are available if the blind is installed on a fixed skylight or any prior skylight or roof window model: For one blind Power Supply and Keypad KES 160 $82 For multiple blinds Power Supply Keypad (required) WLC 160 WLI 160 $195 $85 Remote (optional) Sensor Interface WLR 160 WLF 111 $60 $210 c Prices and product program effective March 1, 2005. Prices and product program subject to change without notice. Call or visit the web site for current pricing and product program. VELUX America Inc. 450 Old Brickyard Road PO Box 5001 Greenwood, SC 29648 -5001 Phone: 1- 800 - 888 -3589 Fax: 1- 864 - 943 -2631 Internet: http: / /www.VELUXusa.com V41SA- 1758-0405 ® VELUX, VELUX logo Primed in U.S.A. i° VSE, Comfort, LightBlock, HealBlock BLINDS AND CONTROLS VELUX® BLINDS AND CONTROLS FOR VELUX SKYLIGHTS AND ROOF WINDOWS 3 easy steps to having blinds installed in your home Find the right blind for your VELUX skylight or roof window: ODetermine the model and size of skylight installed by looking for the identification plate on the skylight. The tag is found in the corner shown with the red dot. You can also use the "HOW TO ORDER" button at www.VELUXusa.com. VS 06 00748 2B AF10A Production X- AMERICA INC. Code P.O. Box 5 1, Grcenwood, SC 29648 ode in U.S.A. SIZE MODEL See charts at right Skylights Roof Curb (Deck Mounted and Self - Flashed): Window: Skylight: 0 fl—w— �r A�� VSE /QVE VS /QVM FS /QFS GPL FCM Electric venti- Ventilated Fixed skylight Top hung pivoting Curb mounted lated skylight skylight with (with Nap FSF) roof window and skylight with chain chain operator the GDL roof balcony opener (several models (prior models GHL, available, take GGL and TPS) note of produc- tion code) © Now you are ready to order. Use the "WHERE TO BUY" button at www.VELUXuso.com to find the VELUX dealer nearest you, then call or visit the dealer to place your order: Specify: A. Model of skylight you own B. The size code C. The production code is needed for older VS skylights D. What kind of blind you want E. What kind of operation you want Example: A. VS ventilated skylight B. Size 106 C. Production code: 28AE10A D. Venetian blind E. Manual operation Your VELUX dealer will provide you with The Perfect match of VELUX blind for your VELUX skylight SIZE Skylights and Roof Windows: VSE, VS, FS, QFS, QVM, QVE, GPL SIZE DIAGRAM (nominal outside frame dimensions) z r n z C C1. X Z d 7 u u 7 [ 0 0 h L f Z n n Z mss 415',.H 21', H 23's, H 3T. H 44; H 4Ts. ►md (Prior size code mentioned in brackets. New roof window sizes are underlined.) FCM SIZE DIAGRAM (nominal inside shaft dimensions) Z N Z Z FCM FS /QFS 2222 QVM FCM 3030 Q 150 FCM FCM FS 2234 FS FCM VS FCM Vs 3046 1 VSE 1 VSE 101191 601 QFS FS /QFS QVM QVM QVE QVE 152 302 FS FS VS Vs VSE VSE 104(6)1 1 304 t i 1 FS FS FS /QFS FS /OFS FS QFS Vs Vs /QVM VS /QVM GPL S06 QVM VSE VSE /QVE VSE /QVE Vs QVE VSE 641 056 106 156 306 1 606 656 FS Fs Vs GPL M08 VSE Vs VSE (62) 121 108 308 FS 112 [ 0 0 h L f Z n n Z mss 415',.H 21', H 23's, H 3T. H 44; H 4Ts. ►md (Prior size code mentioned in brackets. New roof window sizes are underlined.) FCM SIZE DIAGRAM (nominal inside shaft dimensions) Z N Z Z FCM 2222 FCM 3030 FCM FCM 2234 3434 FCM FCM FCM 2246 3046 1 4646 Z N Z X a d / 21 , H 29'. N 33'= N 45= ► Z © Installation service is available in certain regions. Ask your local VELUX dealer, or call VELUX Solutions at 1- 866-358 -3589 to inquire if installation service is available in your area. BLOCK THE LIGHT Perfect for rooms that require total room darkening • Blocks the light so less than 2% enters the room • Convert day into night whenever you want in bedroom, bonus rooms or TV /entertainment rooms; the lightBlock shade excludes even the brightest sunlight • Fabric has an energy efficient aluminum coating on the exterior side that acts as a heat barrier • Can increase the energy efficiency up to 20% and reduce your heating costs due to the better natural climate control in your room • Electric operation available for skylights and manual operation only for roof windows G — L LIGHTBLOCK shade electric Prices start at $233 LIGHTBLOCK" Shade White with Thermo Coating Color 1025 BLOCK THE HEAT Reduce cooling costs and increase room comfort • The best possible control of the heat gain, as the awning is installed on the exterior of the skylight and ensures the heat is blocked before it enters the room • Can reduce the solar heat gain up to 40% more than the already energy efficient Comfort Glazing that comes standard with every VELUX skylight and you will save cooling costs • Allows view to the exterior* due to the net cloth used in the awning • Not visible from the room when the HeatBlock awning is open • Electric operation available for fixed, manual venting, electric venting and curb mounted skylights; manual operation for roof windows G — L only *For curb mounted skylights, the awning is light blocking and does not give any view to the exterior lBlack - Color 50801. HEATBLOCK awning electric Prices start at $284 HEATBLOCK" Charcoal net cloth Color 5060/Black solid cloth Color 5080. Prices effective March 1, 2005 - Subject to change without notice. Coll or visit the web site for current pricing. DIFFUSE THE LIGHT ADJUST THE LIGHT VELUX Cellular Shade Elegant and energy efficient shade softens the light in the room • Offers the best possible insulation due to small air pockets inside the fabric • Increases energy efficiency up to 16% and reduces your heating costs due to the better natural climate control in your room • Controls the direct sun and reduces the glare on your N or PC screen and increases the usage and the flexibility of the great room • Diffuses the light so only 13% enters the room • Elegant blind with no visible cords will fit in any room • Manual cellular shades available for any curb mounted skylights in the shaft dimensions VELUX supplies • Manual and electric operation are available for optimal operation comfort for all other VELUX skylights Cellular shade manual Prices start at $95 Cellular shade electric Prices start at $244 Y Have complete control of the light and your privacy • Adjusts the light so only 11 % enters the room • Optimal light and glare control, as you are able to adjust the direct light in the direction you want, in many cases without blocking the view to the outside • The classic and forever in fashion aluminum venetian blind with no hanging cords and double function in the some operation unit • Good for humid applications such as bathrooms and kitchens and can give you the privacy you need • Can increase the energy efficiency up to 12% and reduce your heating costs due to the better natural climate control in your room • Manual and electric operation are available for optimal operation comfort • Fits all older roof windows and skylights, and easy to retro -fit after the skylight is installed Venetian blind manual Prices start at $76 Venetian blind electric Prices start at $202