December21, 2012
Craig Snowdon
Snowdon & Hopkins,Architects P.C.
PO Box 3340
Vail, CO 81658
Re: Parsons Residence
DearCraig,
This document is intended to show compliance of the addition and alteration of the Parson’s Residence
located at 770Potato Patch Dr. #3, Vail, COwith the 2009 International Energy Conservation Code (2009
IECC). We propose to use a prescriptive approach per sections 402.1-402.3and 403.2.1 of the 2009
IECC. I have also included the inspectionchecklist from the 2009 IECC REScheck program for your use.
Project
The residence at 770 Potato Patch Dr. #3 is aremodel of a condo increasing thefloor area to 2,760sf. This document deals only with the new and remodeled areas of the residence, as existing constructions
are exempt per section 101.4.3 of the code.
Building Envelope
The following table lists the mandatory minimum insulation and fenestration requirements for theclimate
zone (6). All new assemblies will meet the following requirements.
Fenestration
U-factor
Ceiling
R-value
Skylight
U-factor
Wood frame wall R-
value
Floor R-
value
Slab R-
value
Code
Minimums
0.35(3)490.60(3)20 or 13(cavity)+5
(continuous)
30(1)10 (2)
Notes: 1) Or insulation sufficient to fill the framing cavity, R-19 minimum
2) 4 ft deep
3) Fenestration SHGCrequirements do not apply inclimate zone(6)
4) No crawl spaces exist
Sincerely,
David Denio, E.I.T.
Attached: 2009 IECC REScheck Inspection Checklist