HomeMy WebLinkAboutB12-0309 REV 15 PLANS approved1650 Fallridge Road, Suite C-1 Vail, Colorado 81657 P: 970.476.6342 F: 970.476.4901 www.vailarchitects.com PIERCE ARCHITECTS VAIL, COLORADO William F. Pierce, Architect Tyson Dearduff, Director of Architecture Kathy Heslinga, Office Manager ARCHITECT'S SUPPLEMENTAL INFORMATION ASI No: 011 Project: Vail Fire Station #2 / Architect’s Project No. 1204 Date: 07 December 2012 Contractor: GE Johnson Owner: Town of Vail Consultant: N/A Response to: Town of Vail The work outlined in this document shall be carried out in accordance with the following supplemental instructions. This document is intended to cause no change to the Contract Sum or Contract Time, it is issued as a supplemental clarification to work already included in the Contract Documents. Prior to beginning work, the contractor shall notify the architect, in writing, of any Contract Sum or Contract Time variation, which may be incurred as a result of this document. Description: 1. Revisions to Lighting and Electrical Attachments: Revised Sheets dated 06 DEC 2012: E3.0 & E3.2. Issued: Accepted: By: Jim Buckner, AIA By: Pierce Architects 04 DEC 2012 Contractor Date By David Rhoades at 4:30 pm, Jan 02, 2013 TYPEDESCRIPTIONMANUFACTURERCATALOG NUMBERMOUNTINGNOLAMPVOLTSDIMENSIONSREMARKS ARECESSED DOWN LIGHTPRESCOLITEIBX26ICATDM-SBH-T06RECESSED126W TRIPLE TUBE CFL1207 7/8"W X 10 3/4"L X 7 1/2"H BSUSPENDED LINEAR FLUORESCENTALERACVRPB-4-3T8- -CM-48-ED-U-MW-SCE-SUSPENDED332W T812048"L X 9 1/2"W X 2 1/2"H COORD FINISH WITH OWNER CCEILING FAN W/ LIGHTEMERSON FANSHIGHPIOINTESUSPENDED250W HALOGEN12054"DIA CANDELABRA DLINEAR FLUORESCENT WALL FIXTURECOLUMBIAW4-232-EP-UWALL232W T812048"L X 4 7/8" X 4"H SURFACE E4' FLUORESCENT UTILITY WRAPCOLUMBIAWC4-232-EPUSURFACE232W T812048"L X 10"W X 2 1/2"H DAMP LOCATION FOR 2-LAMP BALLAST PROVIDE FLINEAR FLUORESCENT HIGH BAYCOLUMBIALHC24-654-FACA-LS-24EPUSUSPENDED654W T5HO12024"W X 48"L X 5"HLAMPS WITH RED MALCOLITE DAMP LOCATION-GASKETED TUBE GUARD GPENDANTPRESCOLITERDPSCFTSUSPENDED126W TRIPLE TUBE CFL120 HRED EGRESS STEPLIGHTSIO LIGHTING0-01-SL-R-R-5-0WALL18W LED1209 5/8"L X 6"H X 3 3/8"D RECESSED( INCLUDED ) INATURAL LIGHT TUBESOLATUBE160 DSRECESSEDN/AN/AN/A10" DIA JBATHROOM VANITY LIGHTPROGRESSP2709-09EBWBSURFACE413W CFL12030"W X 7 1/2"H KLED STRIP LIGHTSGM LIGHTINGLTAB-NSURFACE2.8W/ FT12V DCCOORDINATE ALL LENGTHS IN FIELD UNDERCOUNTER 3500KPROVIDE DRIVERS PER MANUF REQ'S. LLED STRIP LIGHTSGM LIGHTINGLTR300WP-WWSURFACE2.6W/ FT12V DCCOORDINATE ALL LENGTHS IN FIELD WET LOCATION 3500K PROVIDE DRIVERS PER MANUF REQ'S. MSTAIR SCONCEBORDEN504-CF1\26-120-SALSURFACE126W TRIPLE TUBE CFL120 NSURFACE WRAPCOLUMBIAAD-2-1-17-E-USURFACE117W T8120 PROVIDE SQUARE LENSED SHOWER SSHOWER RECESSED DOWNLIGHTLIGHTOLIER1050SQDLFGWBRECESSED126W TRIPLE TUBE CFL1207 7/8"W X 10 3/4"L X 7 1/2"HTRIM. COORD W/ OWNERS WET LOCATION LISTED AAEXTERIOR RECESESD DOWNLIGHTHALOH285EICAT-26WDTT-406SCRECESSED126W TRIPLE TUBE CFL12013"L X 9 1/2"W X 7 1/2"H BBEXTERIOR RECESSED DOWNLIGHTHALOH247ICATRECESSED126W TRIPLE TUBE CFL12014 3/4"L X 10 1/2"W X 7"H SLOPED CEILING FIXTURE CCEXTERIOR WALL SCONCESHAPER682-WP-11-CFL/2-120-NBZ-BN-PHSURFACE126W TRIPLE TUBE CFL12012"D X 11"W X 10"H LUMINAIRE SCHEDULE NOTE: ALTERNATE EQUIVALENT LIGHTING PACKAGES ACCEPTED WITH ENGINEER'S REVIEW OF SUBMITTAL. By David Rhoades at 4:30 pm, Jan 02, 2013 Reviewed for Code Compliance Code: 2009 International Building Code (IBC) By Martin Haeberle at 3:52 pm, Jan 07, 2013 Reviewed for Code Compliance Code: 2009 International Building Code (IBC) By Martin Haeberle at 3:52 pm, Jan 07, 2013