HomeMy WebLinkAboutB12-0309 REV 12 PLANS approved1650 Fallridge Road, Suite C-1 Vail, Colorado 81657 P: 970.476.6342 F: 970.476.4901 www.vailarchitects.com PIERCE ARCHITECTS VAIL, COLORADO William F. Pierce, Architect Tyson Dearduff, Director of Architecture Kathy Heslinga, Office Manager PROPOSAL REQUEST NUMBER 004 Project: VAIL FIRE STATION #2 Date: 07 DECEMBER 2012 (Update sheet references Underlined / 28 DEC 2012) Owner: TOWN OF VAIL Contractor: GE JOHNSON Consultant: N/A Other: N/A Issued By: PIERCE ARCHITECTS Attachments: Drawings dated 06 DEC 2012: A2.1, A2.2, A7.2, A14.1, M2.0, M2.1, M3.1, P2.0, P2.1, P3.1, E1.2, E2.0, E2.1, E3.0, E3.1, E4.0, FA-1.00, and FP-0.00. COMcheck Information by AEC. This document is intended as neither a Change Order nor a direction to proceed with the work described herein. This document is intended solely as a Request for Proposal, the responses to which shall plainly outline all consequences (costs, credits or status quo), associated as a result of proceeding with this work, if accepted, to the Contract Sum. Additionally, the response to this document shall estimate any impact this change, if accepted, may have on the Contract Time. The contractor shall respond to this RFP within 10 working days of the date above. Description: Complete Employee Housing Units scope of work per the attached documents. UP DNUP DN UP A3.11 A3 . 2 1 A3 . 1 A3.2 2 2 234 1 BB AA CC 5 55' - 4" 46' - 8" FINISH 45' - 2 1/2" 16' - 4" (F . V . ) 24 ' - 2 1 / 4 " (F.V.)31' - 1 3/4" 14' - 0" 16' - 4" 6' - 7 1 / 2 " 8' - 0 3 / 4 " PO L E OF F I C E 11 0 WOMEN 114MEN113 BI O D E C O N 11 9 AI R F I L L S T A T I O N 11 8 WO R K / T O O L S 11 7 EM E R G E N C Y GE N E R A T O R 11 6 TO I L E T 111ENTRY120 HA L L 12 3 JAN 115A2.23 A5 . 11 A5.211A4.1 2 A4 . 1 1 A4.2 1 A4 . 3 2 A4 . 2 2 A4 . 3 3 A4.3 3' - 8" 114 11 1 E1 0 1 11 2 E103E105E104 11 0 B HO S E D R Y 11 2 WE S T S T A I R 12 2 OF F I C E 12 5 APPARATUS 124 ST A I R 12 1 WA T E R E N T R Y 12 6 13' - 4" 11 ' - 8 " 8' - 0 1/4" 4' - 6 3/4" CL R 3' - 1 0 1 / 2 " 15 ' - 7 1 / 4 " 10' - 5 3/4"7' - 8 1/4" 11' - 5 3/4" CL R 3' - 1 0 1 / 2 " 11 0 9' - 0 3 / 4 " 7' - 4 " 5' - 4 " 4' - 3 1/2" 2 A4.4 3' - 1 1 3 / 4 " 4' - 8" 1 1 4' - 2 3/4" 2' - 6 1/4" 4' - 4 3/4" 15 ' - 8 1 / 4 " 4' - 1 1/4" 8' - 7 3/4"E108E107E100 11 6 11"1 11" 8' - 1 1 / 4 " CL R 3' - 1 " 11 " A1 4 . 1 7Type G8" 18 ' - 3 " 119 11 8 12 0 I. T . 12 7 STORAGE 128 2' - 2 1 / 4 " 6 1 E10654A 4 6 4A 7 6 6 54A4J-BOX FOR EMERGENCY DISPATCH PHONE. TOP AT 48" MAXIMUM ABOVE FINISH FLOORDOOR BELL BUTTON AT 48 " MAXIMUM ABOVE FINISH FLOOR 9' - 1"AED AT 48" AFF. LINK TO FACP PER OWNER REQUIREMENTS DOOR BELL BUTTON AT 48 " MAXIMUM ABOVE FINISH FLOOR. RINGS TO DO O R B E L L B U T T O N AT 4 8 " M A X I M U M A B O V E FI N I S H F L O O R . PR O V I D E C H I M E A T UP P E R L E V E L W E S T ST A I R L A N D I N G ( V E R I F Y LO C A T I O N W I T H OW N E R DOOR BELL CHIME9' - 7 1/2"8' - 8"11' - 4" 4' - 3 1 / 2 " J-BOX FOR PROXY CARD READER AT 48"AFF J- B O X F O R P R O X Y CA R D R E A D E R A T 4 8 " AF F J-BOX FOR PROXYCARD READER AT 48"AFF 6' - 11 1/2"4' - 0"2' - 1"-------- 12' - 11 1/2" -- 29' - 1 1/2"2" S / O v e n t 11' - 1 1/4" CLR 10' - 0" 5 3/4" 7 3/4" 115 --- - 8' - 6 3/4" 15' - 7 1/2" 1 9' - 1 1 / 2 " 234 1 B A C 5 9' - 0 3 / 4 " 15' - 7 1/2" 7' - 2 1 / 2 " 5' - 5 3 / 4 " 7' - 8 1/2" ME Z Z A N I N E ST O R A G E ME Z Z A N I N E ST O R A G E ME Z Z A N I N E ST O R A G E 12' - 8 1/4" 29 ' - 1 1 3 / 4 " ME Z Z A N I N E 13 0 1 5' - 1 3 / 4 " 5' - 10 1/4" 4" C o n c r e t e S l a b 4" C o n c r e t e S l a b 4" C o n c r e t e S l a b 4" C o n c r e t e S l a b 4" C o n c r e t e S l a b 4" C o n c r e t e S l a b ME Z Z A N I N E ST O R A G E 24 5 OP E N ME Z Z A N I N E 24 6 ME C H 24 7 3' - 11 1/2" 4' - 0 3 / 4 " 3' - 1 1 3 / 4 " TY P E 1 TY P E 1 A - F U L L H E I G H T T O BO T T O M O F R O O F S T R U C T U R E TY P E 2 - I N T E R I O R D E M I S I N G WA L L T O U N D E R S I D E O F RO O F S T R U C T U R E 1 L A Y E R 5 / 8 " G Y P S U M W A L L B O A R D 2X 4 W O O D S T U D S @ 1 6 " O . C . W I T H S O U N D B A T T S 1 L A Y E R 5 / 8 " G Y P S U M W A L L B O A R D 1 L A Y E R 5 / 8 " G Y P S U M W A L L B O A R D 2X 4 W O O D S T U D S @ 1 6 " O . C . W I T H S O U N D B A T T S 1 L A Y E R 5 / 8 " G Y P S U M W A L L B O A R D 2 L A Y E R 5 / 8 " T Y P E X G Y P S U M W A L L B O A R D 2X 4 W O O D S T U D S @ 1 6 " O . C . W I T H S O U N D B A T T S 2 L A Y E R 5 / 8 " T Y P E X G Y P S U M W A L L B O A R D PR O V I D E S L I P T R A C K W I T H A C O U S T I C IS L O A T I O N A T T O P O F A L L C O N N E C T I O N S T O UN D E R S I D E O F S T R U C T U R E , T Y P I C A L . PR O V I D E S L I P T R A C K W I T H A C O U S T I C IS L O A T I O N A T T O P O F A L L C O N N E C T I O N S T O UN D E R S I D E O F S T R U C T U R E , T Y P I C A L . IN T E R I O R W A L L T Y P E S TY P E 3 2X 4 W O O D S T U D F U R R I N G @ 1 6 " O . C . 1 L A Y E R 5 / 8 " G Y P S U M W A L L B O A R D TY P E 4 1 L A Y E R 5 / 8 " G Y P S U M W A L L B O A R D 2X 6 W O O D S T U D S @ 1 6 " O . C . W I T H S O U N D B A T T S 1 L A Y E R 5 / 8 " G Y P S U M W A L L B O A R D TY P E 5 4" C M U - R E I N F O R C E D P E R S T R U C T U R A L AC R Y L I C E N A M E L P A I N T O R T I L E P E R F I N I S H SC H E D U L E TY P E 6 6" C M U - R E I N F O R C E D P E R S T R U C T U R A L AC R Y L I C E N A M E L P A I N T O R T I L E P E R F I N I S H SC H E D U L E EX I S T I N G T O R E M A I N - F I E L D V E R I F Y TY P E 7 8" C M U - R E I N F O R C E D P E R S T R U C T U R A L AC R Y L I C E N A M E L P A I N T O R T I L E P E R F I N I S H SC H E D U L E TY P E 8 2" W O O D S T U D F U R R I N G O V E R E X I S T I N G 2 X 4 ST U D S 1 L A Y E R 5 / 8 " G Y P S U M W A L L B O A R D ISSUE RECORD 1650 Fallridge Road, Suite C-1 Vail, CO 81657 f.(970) 476-4901 p.(970)476-634242 WEST MEADOW DRIVE VAIL, CO 816579 PR 004 06 DEC 2012 A2.1LEVEL 1 AND MEZZANINE PLANSFIRE STATION #2 RENOVATION PROJECT #120416 JUL 2012 3 / 1 6 " = 1 ' - 0 " 1 Le v e l 1 P l a n Room Finish Schedule - Level 1 Ro o m N u m b e r R o o m N a m e F l o o r F i n i s h B a s e F i n i s h W a l l F i n i s h C e i l i n g F i n i s h 11 0 O F F I C E C A R P E T T I L E R E S I L I E N T B A S E P A I N T - S E M I G L O S S P A I N T E D G Y P B D - S E M I G L O S S 11 1 T O I L E T S E A L E D C O N C N O N E P A I N T - S E M I G L O S S P A I N T E D G Y P B D - S E M I G L O S S 11 2 H O S E D R Y S E A L E D C O N C N O N E P A I N T - S E M I G L O S S P A I N T E D G Y P B D - S E M I G L O S S 11 3 M E N P O R C E L A I N T I L E P O R C E L A I N T I L E P O R C E L A I N T I L E P A I N T E D G Y P B D - S E M I G L O S S 11 4 W O M E N P O R C E L A I N T I L E P O R C E L A I N T I L E P O R C E L A I N T I L E P A I N T E D G Y P B D - S E M I G L O S S 11 5 J A N S E A L E D C O N C R E S I L I E N T B A S E P A I N T - S E M I G L O S S P A I N T E D G Y P B D - S E M I G L O S S 11 6 E M E R G E N C Y GE N E R A T O R SE A L E D C O N C N O N E A C R Y L I C E P O X Y G L O S S A C R Y L I C E P O X Y G L O S S G Y P B D 11 7 W O R K / T O O L S S E A L E D C O N C N O N E A C R Y L I C E P O X Y G L O S S A C R Y L I C E P O X Y G L O S S G Y P B D 11 8 A I R F I L L S T A T I O N S E A L E D C O N C N O N E A C R Y L I C E P O X Y G L O S S A C R Y L I C E P O X Y G L O S S G Y P B D 11 9 B I O D E C O N S E A L E D C O N C N O N E A C R Y L I C E P O X Y G L O S S A C R Y L I C E P O X Y G L O S S G Y P B D 12 0 E N T R Y S E A L E D C O N C R E S I L I E N T B A S E P A I N T - S E M I G L O S S P A I N T E D G Y P B D - S E M I G L O S S 12 1 S T A I R R U B B E R R E S I L I E N T B A S E P A I N T - S E M I G L O S S P A I N T E D G Y P B D - S E M I G L O S S 12 2 W E S T S T A I R R U B B E R R E S I L I E N T B A S E P A I N T - SEMIGLOSSPAINTED GYP BD -SEMIGLOSS 12 3 H A L L S E A L E D C O N C R E S I L I E N T B A S E A C R Y L I C E P O X Y G L O S S P A I N T E D G Y P B D - S E M I G L O S S 12 4 A P P A R A T U S S E A L E D C O N C N O N E A C R Y L I C E P O X Y G L O S S A C R Y L I C E P O X Y G L O S S G Y P B D 12 5 O F F I C E C A R P E T T I L E R E S I L I E N T B A S E P A I N T - S E M I G L O S S P A I N T E D G Y P B D - S E M I G L O S S 12 6 W A T E R E N T R Y S E A L E D C O N C N O N E P A I N T - S E M I G L O S S P A I N T E D G Y P B D - S E M I G L O S S 12 7 I . T . S E A L E D C O N C N O N E P A I N T - S E M I G L O S S P A I N T E D G Y P B D - S E M I G L O S S 12 8 S T O R A G E S E A L E D C O N C N O N E P A I N T - S E M I G L O S S P A I N T E D G Y P B D - S E M I G L O S S 13 0 M E Z Z A N I N E P L Y W O O D N O N E P A I N T - S E M I G LOSSPAINTED GYP BD -SEMIGLOSS 3 / 1 6 " = 1 ' - 0 " 2 Me z z a n i n e L e v e l P l a n 9 Re v i e w e d f o r C o d e C o m p l i a n c e Co d e : 2 0 0 9 I n t e r n a t i o n a l B u i l d i n g C o d e ( I B C ) By Ma r t i n Ha e b e r l e at 2: 0 8 pm , Ja n 07 , 20 1 3 DN DN 234 1 BB AA C 5 8' - 1" UTILITY 215 BEDROOM 222 BEDROOM 219BEDROOM220BEDROOM221TOILET216TOILET217HALL223HALL214STORAGE212 PO L E 213 STORAGE 218 ME C H A N I C A L 21 1 A5 . 12 A5.22 A2.241A4.1 2 A4 . 1 1 A4.2 2 A4 . 2 2 A4 . 3 3 A4.3Steel alt tread access to tower antenna level above 1' - 4 " 29' - 9 3/4"3' - 7 3/4"10' - 4 1/4"10' - 4 1/4"11' - 5 3/4"5' - 11 1/4"4' - 1 1/4"5' - 7 3/4"5' - 10 3/4"9' - 1 1/4"4' - 5 1/2"3' - 2 1/4"8' - 10 1/4" 3' - 6 " 4 1/4" 13' - 4"16' - 4"14' - 0"16' - 4" 24 ' - 2 1 / 4 " 31' - 1 3/4" 6" 2' - 10 3/4"8' - 1" 2 2 2 210 214 215 217 218 219220221222212213211216NORTH STAIR 210 WE S T S T A I R 22 6 KITCHEN 224LIVING225 1A 1 1A 111A11A1A13131A11A1A111A1A1A 3 2 10' - 4"118' - 1 1/2"4' - 2 1/2"2' - 1"15' - 0"14' - 0 3/4" E2 0 3 E2 0 3 B E2 0 2 BA T H 22 8 22 8 E201DECK DE C K DE C K OPEN BELOW 2 A4.4 CL S T R U C T U R E 11 ' - 2 " CL STRUCTURE 11' - 2" 3' - 7 1/4" 3 1A 9' - 11"3' - 0"1A1 1A 15' - 1"3' - 6"2' - 6 3/4"9' - 11 1/2"9' - 11 1/2"9' - 11 1/2"30' - 8"13' - 2"44' - 11 1/2"12' - 3 3/4"8 3/4"4' - 4"12' - 8 1/2"2' - 7 3/4"2' - 11 1/4" 3' - 1 0 3 / 4 " 2' - 4 1 / 4 " 3' - 4 3 / 4 " 4' - 7 " 63' - 2 1/4" 2B R / L I V I N G 24 4 BE D R O O M 24 2 BE D R O O M 23 9 BA T H 23 7 CLOSET 238 BA T H 24 3 KI T C H E N 23 4 HA L L 23 3 W/ D 23 5 CO A T 23 1 CL O S E T 23 2 W/ D 23 0 ST U D I O / L I V I N G 22 9 5' - 1" 5' - 1"5' - 3"8' - 9 1/4"5' - 7 1/2"2' - 3"2' - 3"2' - 5 1/2"4' - 8 1/4" 4' - 0 " 3' - 0"3' - 0 1/4" EQEQ 8' - 10 1/4"13' - 6" 9' - 0"4' - 10" CLR 2' - 6 1/4" 8' - 5" 5' - 10" 3' - 1 0 1 / 2 " 2' - 8 " 2' - 8 " 2' - 8 " 5' - 2 " 4 4 5 4 412' - 7" 1' - 7" 16 ' - 5 " H E A D H E I G H T 9' - 1 1/2" 23' - 2 1/2" 2' - 0"CLR 2' - 6 1/4"8' - 9"9' - 6 1/4" 9' - 8" 4' - 4 1/2" 5' - 5 1/4" 1' - 6" 11' - 3" 10 1/2" 11' - 3" 8' - 9" 1 1A 1 1A 1 1A 1A 1A 1 1A 1A 1 1 1 1 1 1 1A 1 1 1 1 CL R 2' - 6 " 1 8' - 1 3 / 4 " 5' - 2 1 / 4 " 3' - 6 3 / 4 " 2' - 5 3 / 4 " 4' - 6 3 / 4 " R2 3 2 R2 3 1 R2 4 4 R2 3 5 R2 3 7 R2 3 8 R2 4 3 R2 4 2 R2 5 3 R2 4 8 R2 3 9 CL O S E T 24 8 R2 2 9 HA L L 24 0 CL R 2' - 6 " 8 8 8 8 8 88 8 8 CL O S E T 24 1 2' - 1 1 " 9 4' - 10 1/2" 2' - 6 " 2 9' - 0"AL I G N 2' - 6" 6' - 2 1/2" 1' - 1" CLR 3' - 11" 42 " H I G H W A L L A T T O P O F LA N D I N G . P R O V I D E PA I N T E D 5 / 4 X 6 W O O D CA P 9 BE D R O O M 24 9 LI N E O F H E A D W A L L AB O V E A N D F L O O R TR A N S I T I O N B E L O W 1' - 1 " 2' - 7 3 / 4 " 2' - 8" B 5 TO W E R A N T E N N A RO O M 30 1 4 B C 5 3' - 1 1 / 2 " 5' - 0 " C L R 5' - 2 " (5' CLR) 5' - 1 1/2" CL R 4' - 1 0 " CLR 4' - 10" 4' - 7 3 / 4 " 11 " 11' - 2 1/4" CLR 2' - 6" 4' - 1 1 3 / 4 " 4' - 9" 4' - 2 3 / 4 " 1' - 5 1/4" 11 ' - 7 1 / 4 " 5' - 8" 5' - 3 1 / 4 " CLR 1' - 7" CLR 1' - 7" WO M E N 11 4 ME N 11 3 JA N 11 5 1' - 6 " 7' - 0" 3' - 4 1 / 2 " CL R 5' - 0 " 1' - 6" 3' - 4 1 / 2 " 12' - 5 3/4" E1 0 7 E1 0 8 7 7 7 5' - 1 3 / 4 " 30 ' - 9 " 11" 4 B 5 DW RA N G E 5' - 1 3 / 4 " 2' - 0 1 / 4 " 2' - 0 1 / 4 " 1' - 2 " ST O R A G E 21 2 KI T C H E N 22 4 3' - 0" TY P E 1 TY P E 1 A - F U L L H E I G H T T O BO T T O M O F R O O F S T R U C T U R E TY P E 2 - I N T E R I O R D E M I S I N G WA L L T O U N D E R S I D E O F RO O F S T R U C T U R E 1 L A Y E R 5 / 8 " G Y P S U M W A L L B O A R D 2X 4 W O O D S T U D S @ 1 6 " O . C . W I T H S O U N D B A T T S 1 L A Y E R 5 / 8 " G Y P S U M W A L L B O A R D 1 L A Y E R 5 / 8 " G Y P S U M W A L L B O A R D 2X 4 W O O D S T U D S @ 1 6 " O . C . W I T H S O U N D B A T T S 1 L A Y E R 5 / 8 " G Y P S U M W A L L B O A R D 2 L A Y E R 5 / 8 " T Y P E X G Y P S U M W A L L B O A R D 2X 4 W O O D S T U D S @ 1 6 " O . C . W I T H S O U N D B A T T S 2 L A Y E R 5 / 8 " T Y P E X G Y P S U M W A L L B O A R D PR O V I D E S L I P T R A C K W I T H A C O U S T I C IS L O A T I O N A T T O P O F A L L C O N N E C T I O N S T O UN D E R S I D E O F S T R U C T U R E , T Y P I C A L . PR O V I D E S L I P T R A C K W I T H A C O U S T I C IS L O A T I O N A T T O P O F A L L C O N N E C T I O N S T O UN D E R S I D E O F S T R U C T U R E , T Y P I C A L . IN T E R I O R W A L L T Y P E S TY P E 3 2X 4 W O O D S T U D F U R R I N G @ 1 6 " O . C . 1 L A Y E R 5 / 8 " G Y P S U M W A L L B O A R D TY P E 4 1 L A Y E R 5 / 8 " G Y P S U M W A L L B O A R D 2X 6 W O O D S T U D S @ 1 6 " O . C . W I T H S O U N D B A T T S 1 L A Y E R 5 / 8 " G Y P S U M W A L L B O A R D TY P E 5 4" C M U - R E I N F O R C E D P E R S T R U C T U R A L AC R Y L I C E N A M E L P A I N T O R T I L E P E R F I N I S H SC H E D U L E TY P E 6 6" C M U - R E I N F O R C E D P E R S T R U C T U R A L AC R Y L I C E N A M E L P A I N T O R T I L E P E R F I N I S H SC H E D U L E EX I S T I N G T O R E M A I N - F I E L D V E R I F Y TY P E 7 8" C M U - R E I N F O R C E D P E R S T R U C T U R A L AC R Y L I C E N A M E L P A I N T O R T I L E P E R F I N I S H SC H E D U L E TY P E 8 2" W O O D S T U D F U R R I N G O V E R E X I S T I N G 2 X 4 ST U D S 1 L A Y E R 5 / 8 " G Y P S U M W A L L B O A R D ISSUE RECORD 1650 Fallridge Road, Suite C-1 Vail, CO 81657 f.(970) 476-4901 p.(970)476-634242 WEST MEADOW DRIVE VAIL, CO 816579 PR 004 06 DEC 2012 A2.2LEVEL 2 PLAN & ENLARGED PLANSFIRE STATION #2 RENOVATION PROJECT #120416 JUL 2012 3 / 1 6 " = 1 ' - 0 " 1 Le v e l 2 P l a n Room Finish Schedule - Level 2 Ro o m N u m b e r R o o m N a m e F l o o r F i n i s h B a s e F i n i s h W a l l F i n i s h C e i l i n g F i n i s h 21 0 N O R T H S T A I R R U B B E R T I L E R E S I L I E N T BASEPAINT-SEMIGLOSSPAINT-SEMIGLOSS 21 1 M E C H A N I C A L S E A L E D C O N C N O N E PAINT-SEMIGLOSSPAINT-SEMIGLOSS 21 2 S T O R A G E S E A L E D C O N C N O N E P A I N T - S E M I G L O S S P A I N T - S E M I G L O S S 21 3 P O L E V I N Y L T I L E R E S I L I E N T B A S E P A I N T - S E M I G L O S S P A I N T - S E M I G L O S S 21 4 H A L L C A R P E T R E S I L I E N T B A S E P A I N T - S E M I G L O S S P A I N T - S E M I G L O S S 21 5 U T I L I T Y V I N Y L T I L E R E S I L I E N T B A S E P A I N T - S E M I G L O S S P A I N T - S E M I G L O S S 21 6 T O I L E T P O R C E L A I N T I L E P O R C E L A I N T I L E P A I N T - S E M I G L O S S P A I N T - S E M I G L O S S 21 7 T O I L E T P O R C E L A I N T I L E P O R C E L A I N T I L E P A I N T - S E M I G L O S S P A I N T - S E M I G L O S S 21 8 S T O R A G E V I N Y L T I L E R E S I L I E N T B A S E P A I N T - S E M I G L O S S P A I N T - S E M I G L O S S 21 9 B E D R O O M C A R P E T - 2 R E S I L I E N T B A S E P A I N T - S A T I N P A I N T - S A T I N 22 0 B E D R O O M C A R P E T - 2 R E S I L I E N T B A S E P A I N T - S A T I N P A I N T - S A T I N 22 1 B E D R O O M C A R P E T - 2 R E S I L I E N T B A S E P A I N T - S A T I N P A I N T - S A T I N 22 2 B E D R O O M C A R P E T - 2 R E S I L I E N T B A S E P A I N T - S A T I N P A I N T - S A T I N 22 3 H A L L V I N Y L P L A N K R E S I L I E N T BASEPAINT-SATINPAINT-SATIN 22 4 K I T C H E N V I N Y L P L A N K R E S I L I ENT BASEPAINT-SATINPAINT-SATIN 22 5 L I V I N G V I N Y L P L A N K R E S I L I ENT BASEPAINT-SATINPAINT-SATIN 22 6 W E S T S T A I R V I N Y L P L A N K R E S I L I E N T BASEPAINT-SEMIGLOSSPAINT-SEMIGLOSS 22 7 W H I T E B O X N O N E N O N E P R I M E P R I M E 22 8 B A T H C E R A M I C T I L E C E R A M I C T I L E P A I N T - S E M I G L O S S P A I N T - S E M I G L O S S 1 / 4 " = 1 ' - 0 " 2 To w e r L e v e l P l a n 1 / 4 " = 1 ' - 0 " 3 Le v e l 1 P u b l i c R e s t r o o m s P l a n 3 / 8 " = 1 ' - 0 " 4 Le v e l 2 D u t y K i t c h e n P l a n Ro o m F i n i s h S c h e d u l e - E H U & M e z z a n i n e Ro o m N u m b e r R o o m N a m e F l o o r F i n i s h B a s e F i n i s h W a l l F i n i s h C e i l i n g F i n i s h 22 8 B A T H C E R A M I C T I L E C E R A M I C T I L E P A I N T - S E M I G L O S S P A I N T - S E M I G L O S S 22 9 S T U D I O / L I V I N G V I N Y L P L A N K P A I N T E D M D F P A I N T - S E M I G L O S S P A I N T - S E M I G L O S S 23 0 W / D V I N Y L P L A N K P A I N T E D M D F PA I N T - S E M I G L O S S P A I N T - S E M I G L O S S 23 1 C O A T V I N Y L P L A N K P A I N T E D M D F P A I N T - S E M I G L O S S P A I N T - S E M I G L O S S 23 2 C L O S E T C A R P E T P A I N T E D M D F PA I N T - S E M I G L O S S P A I N T - S E M I G L O S S 23 3 H A L L V I N Y L P L A N K P A I N T E D M D F P A I N T - S E M I G L O S S P A I N T - S E M I G L O S S 23 4 K I T C H E N V I N Y L P L A N K P A I N T E D M D F P A I N T - S E M I G L O S S P A I N T - S E M I G L O S S 23 5 W / D V I N Y L P L A N K P A I N T E D M D F PA I N T - S E M I G L O S S P A I N T - S E M I G L O S S 23 6 2 B R / L I V I N G V I N Y L P L A N K P A I N T E D M D F P A I N T - S E M I G L O S S P A I N T - S E M I G L O S S 23 7 B A T H C E R A M I C T I L E C E R A M I C T I L E P A I N T - S E M I G L O S S P A I N T - S E M I G L O S S 23 8 C L O S E T C A R P E T P A I N T E D M D F PA I N T - S E M I G L O S S P A I N T - S E M I G L O S S 23 9 B E D R O O M C A R P E T P A I N T E D M D F PA I N T - S E M I G L O S S P A I N T - S E M I G L O S S 24 0 H A L L C A R P E T P A I N T E D M D F P A I NT - S E M I G L O S S P A I N T - S E M I G L O S S 24 1 C L O S E T C A R P E T P A I N T E D M D F PA I N T - S E M I G L O S S P A I N T - S E M I G L O S S 24 2 B E D R O O M C A R P E T P A I N T E D M D F PA I N T - S E M I G L O S S P A I N T - S E M I G L O S S 24 3 B A T H C E R A M I C T I L E C E R A M I C T I L E P A I N T - S E M I G L O S S P A I N T - S E M I G L O S S 24 4 2 B R / L I V I N G V I N Y L P L A N K P A I N T E D M D F P A I N T - S E M I G L O S S P A I N T - S E M I G L O S S 24 5 M E Z Z A N I N E S T O R A G E N O N E N O N E 24 6 O P E N M E Z Z A N I N E N O N E N O N E 24 7 M E C H N O N E N O N E 24 8 C L O S E T C A R P E T P A I N T E D M D F PA I N T - S E M I G L O S S P A I N T - S E M I G L O S S 24 9 B E D R O O M C A R P E T P A I N T E D M D F PA I N T - S E M I G L O S S P A I N T - S E M I G L O S S 9 9 Re v i e w e d f o r C o d e C o m p l i a n c e Co d e : 2 0 0 9 I n t e r n a t i o n a l B u i l d i n g C o d e ( I B C ) By Ma r t i n Ha e b e r l e at 2: 0 8 pm , Ja n 07 , 20 1 3 EH U ac c e s s i b l e un i t s be i n g pr o v i d e d at St a t i o n 3 pe r TO V pr o g r a m po l i c y A3.11 A3 . 2 1 A3 . 1 A3 . 2 2 2 234 1 B A C 5 1 A4.1 1 A4.2 1 A4 . 3 2 A4 . 2 2 A4 . 3 3 A4.37' - 8"10' - 9 1/4"12' - 5 1/4"1 1/2" / 12" 8' - 4 1 / 2 " 3" / 1 2 " 3" / 1 2 " 7' - 8" 9' - 7 3 / 4 " 10 ' - 8 1 / 2 " 1 1/2" / 12" 1 1/2" / 12"1 1/2" / 12" 7' - 8 " 7' - 8"12' - 6" 8' - 0 " WE S T S T A I R 22 6 PO L E 21 3 LIVING 225 KI T C H E N 22 4 HA L L 21 4 TO I L E T 21 6 TOILET 217 UTILITY 215BEDROOM222 HALL 223 BE D R O O M 21 9 BEDROOM 220BEDROOM221 ST O R A G E 21 2 ME C H A N I C A L 21 1 NORTH STAIR 210 7' - 8 " 8' - 1 3/4" 8' - 0 " 7' - 8 " 11' - 11"14' - 10 3/4" -- 8' - 0 " 8' - 0 " 8' - 0 " 8' - 0 " 8' - 0 " 8' - 0 " 8' - 0 " 8' - 0 " 8' - 0 " 11 ' - 9 1 / 2 " 9 2B R / L I V I N G 24 4 BA T H 23 7 BE D R O O M 23 9 BE D R O O M 24 2 BA T H 24 3 HA L L 24 0 CL O S E T 24 1 KI T C H E N 23 4 HA L L 23 3 W/ D 23 5 ST U D I O / L I V I N G 22 9 CL O S E T 23 2 W/ D 23 0 CO A T 23 1 8' - 0 " 8' - 0 " 12 ' - 2 " 8' - 4 1 / 2 " CL O S E T 23 8 CL O S E T 24 8 8' - 0 " 8' - 0 " 8' - 0 " 8' - 0 " 8' - 0 " 8' - 0 " 8' H I G H S O F F I T O V E R C A B I N E T S 2' - 2 " HA T C H E D A R E A O F 2 X 8 FR A M I N G A N D P L Y W O O D DE C K T O S U P P O R T A T T I C AC C E S S T O M E C H A N I C A L UN I T S 2' x 3 ' A C C E S S P A N E L 2' x 3 ' A C C E S S P A N E L 9ISSUE RECORD 1650 Fallridge Road, Suite C-1 Vail, CO 81657 f.(970) 476-4901 p.(970)476-634242 WEST MEADOW DRIVE VAIL, CO 816579 PR 004 06 DEC 2012 A7.2LEVEL 2 REFLECTED CEILING PLANFIRE STATION #2 RENOVATION PROJECT #120416 JUL 2012 3 / 1 6 " = 1 ' - 0 " 1 Le v e l 2 Re v i e w e d f o r C o d e C o m p l i a n c e Co d e : 2 0 0 9 I n t e r n a t i o n a l B u i l d i n g C o d e ( I B C ) By Ma r t i n Ha e b e r l e at 2: 0 8 pm , Ja n 07 , 20 1 3 3' - 2 " 6 1 /2 " IG 2" IT 4' - 4 1/2" FV 5' - 1" 2' - 8"2"4' - 1" 2' - 1 0 " 2' - 1 0 " TRIM TO SOFFIT 8" FV 2' - 10 3/4" FV 5' - 1" IT IT IT IT IT IT IG IG IG IG 2"1" 2" 6' - 10" 2' - 8"2' - 8"2' - 8" 2" 3' - 0 " 2" 2' - 8 " 5" IG IG IT IT IT 6' - 5 " N L a n d i n g 1 2' - 1 0 1 / 2 " 1' - 2"2' - 8"2"2' - 8"2"2' - 8"2" 5" 2' - 8 " 2" 2' - 8 " SP SP IT IT IT IT 6' - 1 " 3' - 0" 3' - 0 " 2" 2" 2" IT 3' - 6"2"3' - 1"2"3' - 8"2"3' - 1"2"SGSGSG GL A Z I N G T Y P E S K E Y IT IN S U L A T I N G T E M P E R E D SA F E T Y G L A S S U N I T S SP SP A N D R E L I N S U L A T I N G G L A S S U N I T S TS TE M P E R E D S A F E T Y G L A S S U N I T S IG IN S U L A T I N G G L A S S U N I T S SG SP E C I A L G L A Z I N G VARIES SEE SCHEDVA R I E S S E E S C H E D 2' - 6" 6" 6" 6" VARIES SEE SCHED AB 4"VARIES SEE SCHED 4" C VA R I E S S E E S C H E D TS TS 6' - 0"1' - 4" 2' - 1 0 " 2' - 1 0 " 2" 2" 2" 4"7' - 0" TS TS ISSUE RECORD 1650 Fallridge Road, Suite C-1 Vail, CO 81657 f.(970) 476-4901 p.(970)476-634242 WEST MEADOW DRIVE VAIL, CO 816579 PR 004 06 DEC 2012 A14.1OPENINGSANDSCHEDULESFIRE STATION #2 RENOVATION PROJECT #120416 JUL 2012 3 / 8 " = 1 ' - 0 " 1 Ty p e A 3 / 8 " = 1 ' - 0 " 2 Ty p e B 3 / 8 " = 1 ' - 0 " 3 Ty p e C 3 / 8 " = 1 ' - 0 " 4 Ty p e D Window Schedule Ty p e M a r k T y p e SIZE MaterialFinishHeadJambSillCommentsWidthHeight 1A L U M CL A D W D 2' - 0"3' - 4"WOODALUM 2A L U M CL A D W D 2' - 4"6' - 10"WOODALUM 3A L U M CL A D W D 2' - 6"4' - 0"WOODALUM 4A L U M CL A D W D 4' - 0"4' - 0"WOODALUM 5 2 ' - 0 " 2 ' - 0 " W O O D A L U M 6 2 ' - 6 " 2 ' - 6 " W O O D A L U M 7 2 ' - 6 " 4 ' - 0 " W O O D A L U M 8 3 ' - 0 " 1 ' - 6 " W O O D A L U M 9 2 ' - 6 " 1 ' - 6 " W O O D A L U M Do o r S c h e d u l e Do o r Nu m b e r To R o o m Fr o m Ro o m : Na m e Do o r FIRE RATINGFrameComments Wi d t h H e i g h t T h i c k n e s s M a t e r i a l F i n i s h U n d e r C u t M a t e r i a l F i n i s h 11 0 H A L L O F F I C E 2 ' - 1 0 " 7 ' - 0 " 1 3 / 4 " H M P A I N T E D H M P A I N T E D 11 0 B O F F I C E W E S T S T A I R 3 ' - 0 " 7 ' - 0 " 1 3 / 4 " H M P A I N T E D H M P A I N T E D 11 1 T O I L E T A P P A R A T U S 2 ' - 6 " 7 ' - 0 " 1 1 / 2 " H M P A I N T E D H M P A I N T E D 11 2 B I O D E C O N W A T E R E N T R Y 2 ' - 0 " 3 ' - 0 " 1 1 / 2 " H M P A I N T E D H M P A I N T E D 11 4 J A N M E N 2 ' - 4 " 7 ' - 0 " 1 1 / 2 " H M P A I N T E D 1 / 2 " H M P A I N T E D 11 5 H A L L 3 ' - 0 " 7 ' - 0 " 1 3 / 4 " 11 6 H A L L H O S E D R Y 3 ' - 2 " 7 ' - 0 " 1 3 / 4 " H M P A I N T E D H M P A I N T E D 11 8 A P P A R A T U S O F F I C E 2 ' - 1 0 " 7 ' - 0 " 1 1 / 2 " H M A N O D I Z E D A L U M A N O D I Z E D 11 9 E N T R Y S T O R A G E 2 ' - 0 " 7 ' - 0 " 1 3 / 4 " H M P A I N T E D 3 / 4 H R H M P A I N T E D 12 0 W E S T S T A I R I . T . 2 ' - 0 " 7 ' - 0 " 1 3 / 4 " H M P A I N T E D 3 / 4 H R H M P A I N T E D 21 0 N O R T H S T A I R L I V I N G 2 ' - 1 0 " 7 ' - 0 " 1 1 / 2 " W O O D S T A I N E D 3 / 4 H R H M P A I N T E D 21 1 M E C H A N I C A L N O R T H S T A I R 2 ' - 6 " 7 ' - 0 " 1 1 / 2 " W O O D S T A I N E D H M P A I N T E D 21 2 H A L L S T O R A G E 2 ' - 4 " 6 ' - 8 " 1 3 / 4 " W O O D S T A I N E D H M P A I N T E D 21 3 P O L E H A L L 2 ' - 8 " 7 ' - 0 " 1 1 / 2 " W O O D S T A I N E D H M P A I N T E D 21 4 H A L L H A L L 2 ' - 1 0 " 7 ' - 0 " 1 1 / 2 " W O O D S T A I N E D S T E E L P A I N T E D 21 5 U T I L I T Y H A L L 2 ' - 6 " 7 ' - 0 " 1 1 / 2 " W O O D S T A I N E D S T E E L P A I N T E D 21 6 T O I L E T H A L L 2 ' - 4 " 7 ' - 0 " 1 1 / 2 " W O O D S T A I N E D S T E E L P A I N T E D 21 7 T O I L E T H A L L 2 ' - 4 " 7 ' - 0 " 1 1 / 2 " W O O D S T A I N E D S T E E L P A I N T E D 21 8 S T O R A G E H A L L 2 ' - 0 " 7 ' - 0 " 1 3 / 4 " W O O D S T A I N E D S T E E L P A I N T E D 21 9 B E D R O O M H A L L 2 ' - 6 " 7 ' - 0 " 1 1 / 2 " W O O D S T A I N E D S T E E L P A I N T E D 22 0 B E D R O O M H A L L 2 ' - 6 " 7 ' - 0 " 1 1 / 2 " W O O D S T A I N E D S T E E L P A I N T E D 22 1 B E D R O O M H A L L 2 ' - 6 " 7 ' - 0 " 1 1 / 2 " W O O D S T A I N E D S T E E L P A I N T E D 22 2 B E D R O O M H A L L 2 ' - 6 " 7 ' - 0 " 1 1 / 2 " W O O D S T A I N E D S T E E L P A I N T E D 22 8 B A T H B E D R O O M 2 ' - 0 " 7 ' - 0 " 1 3 / 4 " W O O D S T A I N E D H M P A I N T E D E1 0 0 E N T R Y 3 ' - 0 " 6 ' - 1 0 " A L U M A N O D I Z E D A L U M A N O D I Z E D E1 0 1 W E S T S T A I R 3 ' - 0 " 7 ' - 0 " 1 3 / 4 " H M P A I N T E D H M P A I N T E D E1 0 3 A P P A R A T U S 3 ' - 0 " 7 ' - 0 " 1 3 / 4 " H M P A I N T E D H M P A I N T E D E1 0 4 A P P A R A T U S 1 2 ' - 0 " 1 2 ' - 4 " 1 3 / 4 " H M P A I N T E D H M P A I N T E D E1 0 5 A P P A R A T U S 1 2 ' - 0 " 1 2 ' - 4 " 1 3 / 4 " H M P A I N T E D H M P A I N T E D E1 0 6 A P P A R A T U S 1 2 ' - 0 " 1 2 ' - 4 " 1 3 / 4 " H M P A I N T E D H M P A I N T E D E1 0 7 W O M E N 3 ' - 0 " 7 ' - 0 " 1 3 / 4 " H M P A I N T E D H M P A I N T E D E1 0 8 M E N 2 ' - 1 0 " 7 ' - 0 " 1 3 / 4 " H M P A I N T E D H M P A I N T E D E2 0 1 L I V I N G 2 ' - 1 0 " 7 ' - 0 1 / 4 " A L U M A N O D I Z E D A L U M A N O D I Z E D E2 0 2 S T U D I O / LI V I N G 4' - 1 1 1 / 4 " 6 ' - 9 1 / 2 " 1 3 / 4 " W O O D A N O D I Z E D W D A N O D I Z E D E2 0 3 2 B R / L I V I N G 5 ' - 1 1 1 / 4 " 6 ' - 9 1 / 2 " 1 3 / 4 " W O O D A N O D I Z E D W D A N O D I Z E D E2 0 3 B 2 B R / L I V I N G 3 ' - 0 3 / 4 " 6 ' - 8 1 / 4 " 1 3 / 4 " W O O D A N O D I Z E D W D A N O D I Z E D R2 2 9 S T U D I O / LI V I N G HA L L 2 ' - 6 " 6 ' - 8 " 1 3 / 4 " M D F P A I N T E D 6 0 M I N M D F P A I N T E D R2 3 1 S T U D I O / LI V I N G CO A T 2 ' - 0 " 6 ' - 8 " 1 3 / 4 " M D F P A I N T E D M D F P A I N T E D R2 3 2 B E D R O O M C L O S E T 2 ' - 0 " 6 ' - 8 " 1 3 / 4 " M D F P A I N T E D M D F P A I N T E D R2 3 5 W / D 2 B R / L I V I N G 2 ' - 6 " 6 ' - 8 " 1 3 / 4 " M D F P A I N T E D M D F P A I N T E D R2 3 7 B A T H B E D R O O M 2 ' - 4 " 6 ' - 8 " 1 3 / 4 " M D F P A I N T E D M D F P A I N T E D R2 3 8 C L O S E T B E D R O O M 2 ' - 0 " 6 ' - 8 " 1 3 / 4 " M D F P A I N T E D M D F P A I N T E D R2 3 9 B E D R O O M H A L L 2 ' - 6 " 6 ' - 8 " 1 3 / 4 " M D F P A I N T E D M D F P A I N T E D R2 4 2 B E D R O O M H A L L 2 ' - 6 " 6 ' - 8 " 1 3 / 4 " M D F P A I N T E D M D F P A I N T E D R2 4 3 B A T H H A L L 2 ' - 0 " 6 ' - 8 " 1 3 / 4 " M D F P A I N T E D M D F P A I N T E D R2 4 4 2 B R / L I V I N G H A L L 2 ' - 6 " 6 ' - 8 " 1 3 / 4 " M D F P A I N T E D 6 0 M I N M D F P A I N T E D R2 4 8 H A L L C L O S E T 2 ' - 0 " 6 ' - 8 " 1 3 / 4 " M D F P A I N T E D M D F P A I N T E D R2 5 3 C L O S E T B E D R O O M 4 ' - 0 " 6 ' - 8 " 1 3 / 4 " M D F P A I N T E D M D F P A I N T E D 3 / 8 " = 1 ' - 0 " 5 Ty p e E 3/8" = 1'-0"6Type F DO O R T Y P E S NO T E : U - F A C T O R F O R A L L W O O D W I N D O W S S H A L L B E U = 0 . 3 5 M A X I M U M P E R I E C C NO T E : U - F A C T O R F O R E X T E R I O R D O O R S S H A L L B E U = 0 . 8 5 M A X I M U M P E R I E C C 3 / 8 " = 1 ' - 0 " 7 Ty p e G 9 Re v i e w e d f o r C o d e C o m p l i a n c e Co d e : 2 0 0 9 I n t e r n a t i o n a l B u i l d i n g C o d e ( I B C ) By Ma r t i n Ha e b e r l e at 2: 0 8 pm , Ja n 07 , 20 1 3 Reviewed for Code Compliance Code: 2009 International Building Code (IBC) By Martin Haeberle at 2:08 pm, Jan 07, 2013 Reviewed for Code Compliance Code: 2009 International Building Code (IBC) By Martin Haeberle at 2:08 pm, Jan 07, 2013 Reviewed for Code Compliance Code: 2009 International Building Code (IBC) By Martin Haeberle at 2:08 pm, Jan 07, 2013 Reviewed for Code Compliance Code: 2009 International Building Code (IBC) By Martin Haeberle at 2:01 pm, Jan 07, 2013 Reviewed for Code Compliance Code: 2009 International Building Code (IBC) By Martin Haeberle at 2:01 pm, Jan 07, 2013 Reviewed for Code Compliance Code: 2009 International Building Code (IBC) By Martin Haeberle at 2:01 pm, Jan 07, 2013 PROJECT: VAIL FIRE STATION #2 ENGINEER:CTL PROJECT #: 12017 VOLTAGE:120/208V, 3P, 4W MOUNTING: RECESSED MAINS:100A MLO TYPE: AIC:10K PHASE PHASE DESCRIPTION A B CBKR PCIRCIR P BKR A B CDESCRIPTION LIVING ROOM OUTLETS1080 20112120500 LIGHTING LIVING ROOM OUTLETS 1080 20134120 500 LIGHTING BED OUTLETS 90020156120 500LIGHTING BATH OUTLETS230 20178120500 LIGHTING KITCHEN OUTLETS 900 201910120 500 LIGHTING KITCHEN OUTLETS 90020111120 0SPACE FRIDGE1500 20113141201500 WASHER MW 1500 2011516230 2500 DRYER DW 15002011718 2500" DISP1500 20119200 SPACE OVEN/RANGE 1500 2012122 0 SPACE SPACE 02324 0SPACE SPACE0 25260 SPACE SPACE 0 2728 0 SPACE SPACE 02930 0SPACE 0 0 0 0 0 0 0 0 0 0 0 0 LOAD CALCULATION SUMMARY CALCULATED POWER FACTOR: 0.99 CONNECTED LOAD CONNECTED AMPS DEMAND LOAD DEMAND AMPS LIGHTING 10000 28 10000 28 RECEPTACLES 5040 14 5040 14 MECHANICAL 1550 5 1925 6 KITCHEN 5000 14 3250 9 TOTAL 21590 61 20215 57 EHU A PANEL PROJECT: FIRE STATION #2 ENGINEER:CTL PROJECT #: 12017 VOLTAGE:120/208V, 3P, 4W MOUNTING: SURFACE MAINS:100A MLO TYPE: AIC:10K PHASE PHASE DESCRIPTION A B CBKR PCIRCIR P BKR A B CDESCRIPTION LIVING ROOM OUTLETS1080 20112120500 LIGHTING LIVING ROOM OUTLETS 1080 20134120 500 LIGHTING BED OUTLETS 90020156 0SPACE BATH OUTLETS 230 20178 0 SPACE KITCHEN OUTLETS 900 201910 0 SPACE KITCHEN OUTLETS 90020111120 0SPACE FRIDGE 1500 20113141201500 WASHER MW 1500 2011516230 2500 DRYER DW 15002011718 2500" DISP 1500 2011920 0 SPACE OVEN/RANGE 1500 2012122 0 SPACE BED OUTLETS 9002012324 0SPACE BATH OUTLETS 230 2012526 0 SPACE SPACE 0 2728 0 SPACE SPACE 0 2930 0SPACE 0 0 0 0 0 0 0 0 0 0 0 0 LOAD CALCULATION SUMMARY CALCULATED POWER FACTOR: 0.99 CONNECTED LOAD CONNECTED AMPS DEMAND LOAD DEMAND AMPS LIGHTING 1000 3 1000 3 RECEPTACLES 6120 17 6120 17 MECHANICAL 1600 5 1975 6 KITCHEN 12500 35 8125 23 TOTAL 21220 60 17220 49 EHU B PANEL PROJECT: FIRE STATION #2 ENGINEER:CTL PROJECT #: 12017 VOLTAGE:120/208V, 3P, 4W MOUNTING: SURFACE MAINS:200A MLO TYPE: AIC:10K PHASE PHASE DESCRIPTION A B CBKR PCIRCIR P BKR A B CDESCRIPTION KITCHEN OUTLETS 900 201121201000 LIVING /DININGLIGHTING KITCHEN OUTLETS 900 20134120 1000 KITCHEN LIGHTING KITCHEN OUTLETS 90020156120 1000MECH RM LIGHTING FRIDGE 1500 20178 0 SPACE FRIDGE 1500 201910 0 SPACE MW 15002011112 0SPACE DW 1500 2011314 0 SPACE DISPOSAL 1500 2011516 0 SPACE OVEN/RANGE 50002011718 0SPACE DORM LIVING RM OUTLETS540 2011920 0 SPACE DORM LIVING RM OUTLETS 540 2012122 0 SPACE DORM LIVING RM TV 15002012324 0SPACE DINING RM OUTLETS540 2012526 0 SPACE SPACE 0 2728 0 SPACE SPACE 0 2930120 1200WASHER SPACE 0 31321201200 DRYER SPACE 0 3334 0 SPACE SPACE 0 3536 0SPACE SPACE 0 3738 0 SPACE SPACE 0 3940 0 SPACE SPACE 0 4142 0SPACE LOAD CALCULATION SUMMARY CALCULATED POWER FACTOR:PROVIDE FEED THRU LUGS TO DORM B PANEL. LOADS FROM DORM B PANEL ARE SHOWN BELOW. 0.98 CONNECTED LOAD CONNECTED AMPS DEMAND LOAD DEMAND AMPS LIGHTING 4500 12 4500 12 RECEPTACLES 13020 36 11510 32 MECHANICAL 2500 8 2800 9 KITCHEN 12500 35 8125 23 TOTAL 32520 91 26935 76 DORM A PANEL PROJECT: FIRE STATION #2 ENGINEER:CTL PROJECT #: 12017 VOLTAGE:120/208V, 3P, 4W MOUNTING: SURFACE MAINS:100A MLO TYPE: AIC:10K PHASE PHASE DESCRIPTION A B CBKR PCIRCIR P BKR A B CDESCRIPTION BEDROOM OUTLETS1080 20112120500 HALL/UTILITY LIGHTING BEDROOM OUTLETS 1080 20134120 500 DORM LIGHTING BEDROOM OUTLETS 108020156120 500DORM LIGHTING BEDROOM OUTLETS1080 20178 0 SPACE HALL OUTLETS 1080 201910 0 SPACE UTILITY RM OUTLETS 10802011112 0SPACE BATH OUTLETS 410 2011314 0 SPACE BATH OUTLETS 410 2011516 0 SPACE SPACE 0 1718 0SPACE SPACE 0 1920 0 SPACE SPACE 0 2122 0 SPACE SPACE 0 2324 0SPACE SPACE 0 2526 0 SPACE SPACE 0 2728 0 SPACE SPACE 0 2930 0SPACE SPACE 0 3132 0 SPACE SPACE 0 3334 0 SPACE SPACE 0 3536 0SPACE SPACE 0 3738 0 SPACE SPACE 0 3940 0 SPACE SPACE 0 4142 0SPACE LOAD CALCULATION SUMMARY CALCULATED POWER FACTOR:PROVIDE FEED THRU LUGS TO DORM A PANEL. LOADS FROM THIS PANEL ARE SHOWN ON DORM A PANEL 1.00 CONNECTED LOAD CONNECTED AMPS DEMAND LOAD DEMAND AMPS LIGHTING 1500 4 1500 4 RECEPTACLES 7200 20 7200 20 MECHANICAL 100 0 112.5 0 KITCHEN 0 0 0 0 TOTAL 8800 24 8813 24 DORM B PANEL PROJECT: FIRE STATION #2 ENGINEER:CTL PROJECT #: 12017 VOLTAGE:120/208V, 3P, 4W MOUNTING: SURFACE MAINS:200A MLO TYPE: AIC:10K PHASE PHASE DESCRIPTION A B CBKR PCIRCIR P BKR A B CDESCRIPTION MENS PUBLIC BATH430 20112120352 EXTERIOR LIGHTING WOMENS PUBLIC BATH 430 20134120 256 ENTRY STAIR LIGHTING HALL OUTLETS 120020156120 584OFFICE/HALL LIGHTING OFFICE OUTLETS 1500 20178120500 WEST STAIR LIGHTING OFFICE OUTLETS 1500 201910120 1280 GARAGE LIGHTING OFFICE OUTLETS 15002011112120 320GARAGE LIGHTING GARAGE OUTLETS 1080 2011314120305 BATH LIGHTING/POWER GARAGE OUTLETS 1080 2011516120 0 FLAG LIGHTING (FUTURE) GARAGE OUTLETS 10802011718120 1800HAND DRYER GARAGE DOOR 1200 20119201201800 HAND DRYER GARAGE DOOR 1200 2012122120 720 OFFICE OUTLETS GARAGE DOOR 12002012324120 320MEZZANINE LIGHTING ENGINE BLOCK HEATERS1800 2012526 0 SPACE EXTERIOR OUTLETS 720 2012728 0 SPACE HOLIDAY LIGHTING 10002012930 0SPACE SPACE 0 3132 0 SPACE SPACE 0 3334 0 SPACE SPACE 0 3536 0SPACE SPACE 0 3738 0 SPACE INFORMATION KIOSK 1500 2013940 0 SPACE LV TRANSFORMER 5002014142 0SPACE LOAD CALCULATION SUMMARY CALCULATED POWER FACTOR:PROVIDE FEED THROUGH LUGS FOR CONNECTION TO FUTURE GARAGE B PANEL 0.95 CONNECTED LOAD CONNECTED AMPS DEMAND LOAD DEMAND AMPS LIGHTING 4987 14 4987 14 RECEPTACLES 14720 41 12360 34 MECHANICAL 7450 24 7900 26 KITCHEN 0 0 0 0 TOTAL 27157 79 25247 74 GARAGE A PANEL PROJECT: FIRE STATION #2 ENGINEER:CTL PROJECT #: 12017 VOLTAGE:120/208V, 3P, 4W MOUNTING: SURFACE MAINS:200A MLO TYPE: AIC:10K PHASE PHASE DESCRIPTION A B CBKR PCIRCIR P BKR A B CDESCRIPTION SPACE 0 12 0 SPACE SPACE 0 34 0 SPACE SPACE 0 56 0SPACE SPACE 0 78 0 SPACE SPACE 0 910 0 SPACE SPACE 0 1112 0SPACE SPACE 0 1314 0 SPACE SPACE 0 1516 0 SPACE SPACE 0 1718 0SPACE SPACE 0 1920 0 SPACE SPACE 0 2122 0 SPACE SPACE 0 2324 0SPACE SPACE 0 2526 0 SPACE SPACE 0 2728 0 SPACE SPACE 0 2930 0SPACE SPACE 0 3132 0 SPACE SPACE 0 3334 0 SPACE SPACE 0 3536 0SPACE SPACE 0 3738 0 SPACE SPACE 0 3940 0 SPACE SPACE 0 4142 0SPACE LOAD CALCULATION SUMMARY CALCULATED POWER FACTOR:PROVIDE FEED THROUGH LUGS FOR CONNECTION TO FUTURE GARAGE B PANEL #DIV/0! CONNECTED LOAD CONNECTED AMPS DEMAND LOAD DEMAND AMPS LIGHTING 0 0 0 0 RECEPTACLES 0 0 0 0 MECHANICAL 0 0 0 0 KITCHEN 0 0 0 0 TOTAL 0 0 0 0 GARAGE B PANEL (FUTURE) Reviewed for Code Compliance Code: 2009 International Building Code (IBC) By Martin Haeberle at 2:01 pm, Jan 07, 2013 KWAMPSL(IN)H(IN)W(IN) UH-1 RAYWALL HF4475T2RP SEE PLANSWALL MOUNTED256045.095.00.753.11783.5-INTERLOCK W/ T-STAT, CONSULT LOCATION W/ ARCHITECT UH-2 RAYWALL HF4420T2RP SEE PLANSWALL MOUNTED682645.095.02.008.31783.5-INTERLOCK W/ T-STAT, CONSULT LOCATION W/ ARCHITECT UH-3 RAYWALL HF4410T2RP SEE PLANSWALL MOUNTED341345.095.01.004.21783.5-INTERLOCK W/ T-STAT, CONSULT LOCATION W/ ARCHITECT ELECTRIC UNIT HEATER SCHEDULE OR EQUIVALENT SERVICELOCATION V / PH / Hz OPER. WT. (LBS) DIMENSIONS 208/1/60 ELECTRICAL DATAEAT (°F) LAT (°F)REMARKSUNIT TAG MANUFACTURER & MODEL NO. CAPACITY (BTUH) 208/1/60 208/1/60 TAG DESCRIPTION LOAD VOLTAGE PHASE WIRE SIZE (CU)CONNECTION CIRCUIT BREAKER REMARKS THERMAL B-1,2BOILER500W1201(2#12CU,1#12CUG)1/2"COVERLOAD20A1P PROTECTION CH-1CHILLER6.5 MCA2083(4#12CU,1#12CUG)1"C30/320A3P CU-1CONDENSING UNIT26.4 MCA2081(3#8CU,1#12CUG)1"C60/240A2P THERMAL EF-1EXHAUST FAN21W1201(2#12CU,1#12CUG)1/2"COVERLOAD20A1P PROTECTION THERMAL EF-2EXHAUST FAN62W1201(2#12CU,1#12CUG)1/2"COVERLOAD20A1P PROTECTION THERMAL FC-1FAN COIL1/10HP1201(2#12CU,1#12CUG)1/2"COVERLOAD20A1P PROTECTION THERMAL FC-2,3,4,5FAN COIL1/6HP1201(2#12CU,1#12CUG)1/2"COVERLOAD20A1P PROTECTION THERMAL GF-1,2,3GLYCOL FEEDER50W1201(2#12CU,1#12CUG)1/2"COVERLOAD20A1P PROTECTION THERMAL HRV-1HEAT RECOVERY VENTILATOR40W1201(2#12CU,1#12CUG)1/2"COVERLOAD20A1P PROTECTION P-1,2,3PUMP92W2081(3#12CU,1#12CUG)1"C30/220A2P THERMAL P-4PUMP45W1201(2#12CU,1#12CUG)1/2"COVERLOAD20A1P PROTECTION THERMAL P-5PUMP85W1201(2#12CU,1#12CUG)1/2"COVERLOAD20A1P PROTECTION P-6PUMP370W2081(2#12CU,1#12CUG)1/2"C30/220A2P P-7PUMP1/2HP2081(2#12CU,1#12CUG)1/2"C30/220A2P MECHANICAL SCHEDULE Reviewed for Code Compliance Code: 2009 International Building Code (IBC) By Martin Haeberle at 2:01 pm, Jan 07, 2013 Reviewed for Code Compliance Code: 2009 International Building Code (IBC) By Martin Haeberle at 2:01 pm, Jan 07, 2013 TYPEDESCRIPTION MANUFACTURERCATALOG NUMBER MOUNTINGNOLAMP VOLTSDIMENSIONS REMARKS ARECESSED DOWN LIGHT PRESCOLITEIBX26ICATDM-SBH-T06 RECESSED126W TRIPLE TUBE CFL1207 7/8"W X 10 3/4"L X 7 1/2"H BSUSPENDED LINEAR FLUORESCENTALERA CVRPB-4-3T8- -CM-48-ED-U-MW-SCE-SUSPENDED332W T8 12048"L X 9 1/2"W X 2 1/2"H COORD FINISH WITH OWNER CCEILING FAN W/ LIGHT EMERSON FANSHIGHPIOINTE SUSPENDED250W HALOGEN 12054"DIA CANDELABRA DLINEAR FLUORESCENT WALL FIXTURECOLUMBIA W4-232-EP-U WALL 232W T8 12048"L X 4 7/8" X 4"H SURFACE E4' FLUORESCENT UTILITY WRAP COLUMBIA WC4-232-EPU SURFACE 232W T8 12048"L X 10"W X 2 1/2"H DAMP LOCATION FOR 2-LAMP BALLAST PROVIDE FLINEAR FLUORESCENT HIGH BAY COLUMBIA LHC24-654-FACA-LS-24EPU SUSPENDED654W T5HO 12024"W X 48"L X 5"H LAMPS WITH RED MALCOLITE DAMP LOCATION-GASKETED TUBE GUARD GPENDANT PRESCOLITERDPSCFT SUSPENDED126W TRIPLE TUBE CFL120 HRED EGRESS STEPLIGHTS IO LIGHTING0-01-SL-R-R-5-0 WALL 18W LED 1209 5/8"L X 6"H X 3 3/8"D RECESSED ( INCLUDED ) INATURAL LIGHT TUBE SOLATUBE 160 DS RECESSEDN/A N/A N/A10" DIA JBATHROOM VANITY LIGHT PROGRESS P2709-09EBWB SURFACE 413W CFL 12030"W X 7 1/2"H KLED STRIP LIGHTS GM LIGHTINGLTAB-N SURFACE 2.8W/ FT 12V DC COORDINATE ALL LENGTHS IN FIELD UNDERCOUNTER 3500K PROVIDE DRIVERS PER MANUF REQ'S. LLED STRIP LIGHTS GM LIGHTINGLTR300WP-WW SURFACE 2.6W/ FT 12V DC COORDINATE ALL LENGTHS IN FIELD WET LOCATION 3500K PROVIDE DRIVERS PER MANUF REQ'S. MSTAIR SCONCE BORDEN 504-CF1\26-120-SAL SURFACE 126W TRIPLE TUBE CFL120 NSURFACE WRAP COLUMBIA AD-2-1-17-E-U SURFACE 117W T8 120 PROVIDE SQUARE LENSED SHOWER SSHOWER RECESSED DOWNLIGHTLIGHTOLIER1050SQDLFGWB RECESSED126W TRIPLE TUBE CFL1207 7/8"W X 10 3/4"L X 7 1/2"HTRIM. COORD W/ OWNERS WET LOCATION LISTED AAEXTERIOR RECESESD DOWNLIGHTHALO H285EICAT-26WDTT-406SC RECESSED126W TRIPLE TUBE CFL12013"L X 9 1/2"W X 7 1/2"H BBEXTERIOR RECESSED DOWNLIGHTHALO H247ICAT RECESSED126W TRIPLE TUBE CFL12014 3/4"L X 10 1/2"W X 7"H SLOPED CEILING FIXTURE CCEXTERIOR WALL SCONCE SHAPER 682-WP-11-CFL/2-120-NBZ-BN-PH SURFACE 126W TRIPLE TUBE CFL12012"D X 11"W X 10"H LUMINAIRE SCHEDULE NOTE: ALTERNATE EQUIVALENT LIGHTING PACKAGES ACCEPTED WITH ENGINEER'S REVIEW OF SUBMITTAL. Reviewed for Code Compliance Code: 2009 International Building Code (IBC) By Martin Haeberle at 2:01 pm, Jan 07, 2013 Reviewed for Code Compliance Code: 2009 International Building Code (IBC) By Martin Haeberle at 2:01 pm, Jan 07, 2013 Reviewed for Code Compliance Code: 2009 International Building Code (IBC) By Martin Haeberle at 2:01 pm, Jan 07, 2013