HomeMy WebLinkAboutA13-0002DF-52356:C • 4/13/2012 — Page 1 of 2 MMF-302-6(A) Six-Zone Interface Module Addressable Devices DF-52356:C • E-910 General FireLite’s MMF-302-6 six-zone interface module provides aninterface between the intelligent alarm system and a two-wire conventional detection zone. A common SLC input is used for all modules, and the initiating device circuits share a common external supervisory supply and ground. Otherwise, each module operates independently from the others. The first module is addressed from 01 to 154 while the remain- ing modules are automatically assigned to the next five higher addresses. Provisions are included for disabling a maximum of two unused modules. All two-wire detectors being monitored must be two-wire-compatibility-listed with the modules. TheMMF-302-6 transmits the status of a zone of two-wire detec- tors to the fire alarm control panel. Status conditions are reported as normal, open, or alarm. The interface modulesupervises the zone of detectors and the connection of the external power supply. Each MMF-302-6 module has panel-controlled bicolor LED indicators. The panel can cause the LEDs to blink, latch on, or latch off. Features •Six addressable Class B or three addressable Class A initi- ating device circuits. •Removable 12 AWG (3.1 mm²) to 18 AWG (0.78 mm²) plug- in terminal blocks. •Status indicators for each point. •Unused addresses may be disabled. •Rotary address switches. •Class A or Class B operation. •LiteSpeed or CLIP operation. •Mount one or two modules in a BB-2F cabinet (optional). •Mount up to six modules on a CHS-6 chassis in a BB-6F cabinet (optional). •Mounting hardware included. Specifications Standby current: 2.0 mA (SLC current draw with all addresses used; if some addresses are disabled, the standby current decreases). Alarm current: 40 mA (assumes all six LEDs solid ON). Temperature range: 32°F to 120°F (0°C to 49°C). Humidity: 10% to 85% noncondensing. Dimensions: 6.8" (172.72 mm) high x 5.8" (147.32 mm) widex 1.25" (31.75 mm) deep. Shipping weight: 1.1 lb. (0.499 kg) including packaging. Mounting options: BB-2F cabinet, CHS-6 chassis, or BB-6F cabinet. Wire gauge: 12 AWG (3.1 mm²) to 18 AWG (0.78 mm²). MMF-302-6 is shipped in Class B position: Remove shunt for Class A operation. Maximum SLC wiring resistance: 40 or 50 ohms, panel dependent. Maximum IDC wiring resistance: 25 ohms. External supply voltage: DC voltage: 18 – 28 volts power- limited. Ripple voltage: 0.1 Vrms maximum. External supply current: 90 mA maximum per address in alarm. In Class Boperation, 540 mA maximum for all six addresses in alarm. In Class A operation, 270 mA maximum for all three addresses in alarm. Compatible detectors: See the Device Compatibility Docu- ment. Agency Listings and Approvals These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applicationsmay not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. •UL Listed: S2424. •ULC Listed: S2424 (MMF-302-6A). •MEA Listed: 385-02-E. •CSFM: 7300-0075:0185. •FM Approved. Product Line Information MMF-302-6: Six-zone conventional-detector interface module. MMF-302-6A: Same as above with ULC Listing. BB-2F: Optional cabinet for one or two modules. Dimensions,DOOR: 9.234" (23.454 cm) wide (9.484" [24.089 cm] including hinges), x 12.218" (31.0337 cm) high, x 0.672" (1.7068 cm) deep; BACKBOX: 9.0" (22.860 cm) wide (9.25" [23.495 cm] including hinges), x 12.0" (30.480 cm) high x 2.75" (6.985 cm); CHASSIS (installed): 7.150" (18.161 cm) wide overall x 7.312" 6925xp6m.jpg Page 2 of 2 — DF-52356:C • 4/13/2012 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Fire•Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105.www.firelite.com FireLite® and LiteSpeed® are registered trademarks of Honeywell International Inc. ©2012 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. Made in the U.S. A. (18.5725 cm) high interior overall x 2.156" (5.4762 cm) deep overall. BB-6F: Optional cabinet for up to six modules mounted on CHS-6 chassis (below). Dimensions, DOOR: 24.0" (60.96 cm) wide x 12.632" (32.0852 cm) high, x 1.25" (3.175 cm) deep, hinged at bottom; BACKBOX: 24.0" (60.96 cm) wide x 12.550" (31.877 cm) high x 5.218" (13.2537 cm) deep. CHS-6: Chassis, mounts up to six modules in a BB-6F cabinet. DF-52121:C • 10/06/2010 — Page 1 of 4 MMF-300(A) Series, MDF-300(A) Addressable Monitor Modules Addressable Devices DF-52121:C • E-325 General Four different monitor modules are available for Fire•Lite’sintelligent control panels to suit a variety of applications. Moni- tor modules are used to supervise a circuit of dry-contact input devices, such as conventional heat detectors and pull stations, or monitor and power a circuit of two-wire smoke detectors (MMF-302(A)). MMF-300(A) is a standard-sized module (typically mounts to a 4" [10.16 cm] square box) that supervises either a Style D (Class A) or Style B (Class B) circuit of dry-contact input devices. MMF-301(A) is a miniature monitor module a mere 1.3" (3.302cm) H x 2.75" (6.985 cm) W x 0.5" (1.270 cm) D used to super- vise a Style B (Class B) circuit of dry-contact input devices. Its compact design allows the MMF-301(A) to be mounted in asingle-gang box behind the device it monitors. MMF-302(A) is a standard-sized module used to monitor and supervise compatible two-wire, 24 volt, smoke detectors on a Style D (Class A) or Style B (Class B) circuit. MDF-300(A) is a standard-sized dual monitor module used to monitor and supervise two independent two-wire Style B (Class B) dry-contact initiating device circuits (IDCs) at twoseparate, consecutive addresses in intelligent, two-wire systems. LiteSpeed™ is a communication protocol developed by Fire•Lite Engineering that greatly enhances the speed of com-munication between analog intelligent devices. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new information, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other designs. designs. MMF-300(A) Monitor Module •Built-in type identification automatically identifies this deviceas a monitor module to the control panel. •Powered directly by two-wire SLC loop. No additional power required. •High noise (EMF/RFI) immunity. •SEMS screws with clamping plates for ease of wiring. •Direct-dial entry of address: 01 – 159 on MS-9600 series panels, 01 – 99 on other compatible systems. •LED flashes during normal operation and latches on steady to indicate alarm. The MMF-300(A) Monitor Module is intended for use in intelli-gent, two-wire systems, where the individual address of each module is selected using the built-in rotary switches. It pro- vides either a two-wire or four-wire fault-tolerant Initiating Device Circuit (IDC) for normally-open-contact fire alarm and supervisory devices. The module has a panel-controlled LED indicator. The MMF-300(A) can be used to replace M300(A) modules in existing systems. MMF-300(A) APPLICATIONS Use to monitor a zone of four-wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally-open dry-contact alarm activation devices. May also be used to monitor normally-open supervisory devices with special supervisory indication at the control panel. Monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Circuit. A 47K ohm End-of-Line Resistor (provided) terminates the Style B circuit. No resistor is required for supervision of the Style D circuit. MMF-300(A) OPERATION Each MMF-300(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/nor- mal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limitations on the loop). MMF-300(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.0 mA (LED on). Average operating current: 350 μA (LED flashing), 1 com- munication every 5 seconds, 47k EOL. Maximum IDC wiring resistance: 40 ohms. EOL resistance: 47K ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. MMF-300(A) (TypeH) 69 9 9 c o v . j p g Page 2 of 4 — DF-52121:C • 10/06/2010 MMF-301(A) Mini Monitor Module •Built-in type identification automatically identifies this device as a monitor module to the panel. •Powered directly by two-wire SLC loop. No additional power required. •High noise (EMF/RFI) immunity. •Tinned, stripped leads for ease of wiring. •Direct-dial entry of address: 01 – 159 on MS-9600 seriespanels, 01 – 99 on other compatible systems The MMF-301(A) Mini Monitor Module can be installed in a single-gang junction directly behind the monitored unit. Its small size and light weight allow it to be installed without rigid mounting. The MMF-301(A) is intended for use in intelligent, two-wire systems where the individual address of each module is selected using rotary switches. It provides a two-wire initiat-ing device circuit for normally-open-contact fire alarm devices. The MMF-301(A) can be used to replace M301(A) modules in existing systems. MMF-301(A) APPLICATIONS Use to monitor a single device or a zone of four-wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally-open dry-contact devices. May also be used to monitor normally-open supervisory devices with special super- visory indication at the control panel. Monitored circuit/device is wired as an NFPA Style B (Class B) Initiating Device Circuit.A 47K ohm End-of-Line Resistor (provided) terminates the cir- cuit. MMF-301(A) OPERATION Each MMF-301(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/nor- mal/short) of its Initiating Device Circuit (IDC). MMF-301(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Average operating current: 350 μA, 1 communication every5 seconds, 47k EOL; 600 μA Max. (Communicating, IDC Shorted). Maximum IDC wiring resistance: 40 ohms. Maximum IDC Voltage: 11 Volts. Maximum IDC Current: 400 μA. EOL resistance: 47K ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 1.3" (3.302 cm) high x 2.75" (6.985 cm) wide x 0.65" (1.651 cm) deep. Wire length: 6" (15.24 cm) minimum. MMF-302(A) Interface Module •Supports compatible two-wire smoke detectors. •Supervises IDC wiring and connection of external powersource. •High noise (EMF/RFI) immunity. •SEMS screws with clamping plates for ease of wiring. •Direct-dial entry of address: 01 – 159 on MS-9600 series panels, 01 – 99 on other compatible systems. •LED flashes during normal operation. •LED latches steady to indicate alarm on command from control panel. The MMF-302(A) Interface Module is intended for use in intelli- gent, addressable systems, where the individual address of each module is selected using built-in rotary switches. This module allows intelligent panels to interface and monitor two- wire conventional smoke detectors. It transmits the status (nor- mal, open, or alarm) of one full zone of conventional detectors back to the control panel. All two-wire detectors being moni- tored must be UL compatible with the module. The MMF- 302(A) can be used to replace M302(A) modules in existingsystems. MMF-302 (A) APPLICATIONS Use the MMF-302(A) to monitor a zone of two-wire smoke detectors. The monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Circuit. A 3.9 K ohm End-of-Line Resistor (provided) terminates the end of the Style B or D (class B or A) circuit (maximum IDCloop resistance is 25 ohms). Install ELR across terminals 8 and 9 for Style D application. MMF-302(A) OPERATION Each MMF-302(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/nor- mal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limitations on the loop). MMF-302(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Maximum IDC wiring resistance: 25 ohms. Average operating current: 300 μA, 1 communication and 1 LED flash every 5 seconds, 3.9k eol. EOL resistance: 3.9K ohms. External supply voltage (between Terminals T3 and T4): DC voltage: 24 volts power limited. Ripple voltage: 0.1 Vrms maximum. Current: 90 mA per module maximum. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. 67 2 0 m 1 0 1 . w m f DF-52121:C • 10/06/2010 — Page 3 of 4 MDF-300(A) Dual Monitor Module The MDF-300(A) Dual Monitor Module is intended for use in intelligent, two-wire systems. It provides two independent two-wire initiating device circuits (IDCs) at two separate, consecutive addresses. It is capable of monitoring normally open contact fire alarm and supervisory devices. The module has a single panel- controlled LED. NOTE: The MDF-300(A) provides two Style B (Class B) IDC cir- cuits ONLY. Style D (Class A) IDC circuits are NOT supported in any application. MDF-300(A) SPECIFICATIONS Normal operating voltage range: 15 to 32 VDC. Maximum current draw: 6.4 mA (LED on). Average operating current: 750 μA (LED flashing). Maximum IDC wiring resistance: 1,500 ohms. Maximum IDC Voltage: 11 Volts. Maximum IDC Current: 240 μA EOL resistance: 47K ohms. Maximum SLC Wiring resistance: 40 Ohms. Temperature range: 32° to 120°F (0° to 49°C). Humidity range: 10% to 93% (non-condensing). Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 2.125" (5.398 cm) deep. MDF-300(A) AUTOMATIC ADDRESSING The MDF-300(A) automatically assigns itself to two address- able points, starting with the original address. For example, if the MDF-300(A) is set to address “26”, then it will automati-cally assign itself to addresses “26” and “27”. NOTE: “Ones” addresses on the MDF-300(A) are 0, 2, 4, 6, or 8 only. Terminals 6 and 7 use the first address, and terminals 8 and 9 use the second address. Installation MMF-300(A), MMF-302(A), and MDF-300(A) modules mount directly to a standard 4" (10.16 cm) square, 2.125" (5.398 cm) deep, electrical box. They may also be mounted to the SMB500 surface-mount box. Mounting hardware and installa- tion instructions are provided with each module. All wiring must conform to applicable local codes, ordinances, and regu-lations. These modules are intended for power-limited wiring only. The MMF-301(A) module is intended to be wired and mountedwithout rigid connections inside a standard electrical box. All wiring must conform to applicable local codes, ordinances, and regulations. Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. •UL: S2424 •ULC: S2424 •FM Approved •CSFM: 7300-0075:0185 •MEA: 72-01-E Product Line Information NOTE: “A” suffix indicates ULC-listed model. MMF-300(A): Monitor module. MMF-301(A): Monitor module, miniature. MMF-302(A): Monitor module, two-wire detectors. MDF-300(A): Monitor module, dual, two independent Class B circuits. SMB500: Optional surface-mount backbox. NOTE: See installation instructions and refer to the SLC Wiring Manual, PN 51309. Architects’/Engineers’ Specifications Specifications of these devices and all FireLite products areavailable from FireLite. !CAUTION: Avoid duplicating addresses on the system. Page 4 of 4 — DF-52121:C • 10/06/2010 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Fire•Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105.www.firelite.com Fire·Lite® and LiteSpeed® are registered trademarks and FireWatch™ is atrademark of Honeywell International Inc.©2010 by Honeywell International Inc. All rights reserved. Unauthorized useof this document is strictly prohibited. Made in the U.S. A. DF-60601:A1 • 12/07/2010 — Page 1 of 6 MS-9200UDLS(E) Rev 3 Intelligent Addressable FACP with Built-In Communicator Addressable Fire Alarm Control Panel DF-60601:A1 • A1-60 52 4 2 2 c o v . j p g General The Fire•Lite MS-9200UDLS Rev 3 with Version 5.0 firmware is a combination FACP (Fire Alarm Control Panel) and DACT (Digital Alarm Communicator/Transmitter) all on one circuit board. This compact intelligent addressable control panel has an extensive list of powerful features. While the MS-9200UDLS Rev 3 may be used with an SLC configured in the CLIP (Classic Loop Interface Protocol) mode, it can also operate in LiteSpeed™ mode—Fire•Lite’s latest polling technology—for a quicker device response time. LiteSpeed’s patented technology polls 10 devices at a time. This improvement allows a fully-loaded panel with up to 198 devices to report an incident and activate the notification cir- cuits in under 10 seconds. With Litespeed polling, devices can be wired on standard twisted, unshielded wire up to a distance of 10,000 feet. The MS-9200UDLS Rev 3’s quick-remove chassis protects the electronics during construction. The backbox can be installed allowing field wiring to be pulled. When construction is com- pleted, the electronics can be quickly installed with just two bolts. New features for Rev 3 with Version 5.0 firmware include removable terminal blocks, improved transient protection, additional secondary ANN-BUS, and increased power for the resettable and remote sync outputs. Available accessories include ANN-BUS devices as well as ACS LED, graphic and LCD annunciators, and reverse polar- ity/city box transmitter. The integral DACT transmits system status (alarms, superviso- ries, troubles, AC loss, etc.) to a Central Station via the public switched telephone network. It also allows remote and local programming of the control panel using the PS-Tools Upload/ Download utility. In addition, the control panel may be pro- grammed or interrogated off-site via the public switched tele- phone network. Any personal computer with Windows® XP or greater, a compatible modem, and PS-Tools—the Fire•Lite Upload/Download software kit—may serve as a Service Termi- nal. This allows download of the entire program or upload of the entire program, history file, walktest data, current status and system voltages. The panel can also be programmed through the FACP’s keypad or via a standard PS-2 computer keyboard, which can be plugged directly into the printed circuit board. This permits easy typing of address labels and other programming information. Version 5.0 firmware supports the following: Primary and Sec- ondary ANN-bus devices, AD355 (LiteSpeed), USB port, NAC circuit diagnostics, a new report has been added to the walk- test that lists untested devices, new device types added: audio telephone type code for ACC 25/50ZST, Photo Supervisory and auto-resettable Drill (non-latching). The FireWatch Series internet monitoring modules IPDACT-2 and IPDACT-2UD permit monitoring of alarm signals over the Internet saving the monthly cost of two dedicated business telephone lines. Although not required, the secondary tele- phone line may be retained providing backup communication over the public switched telephone line. NOTE: Unless otherwise specified, the term MS-9200UDLS is used in this document to refer to both the MS-9200UDLS and the MS-9200UDLS(E) FACPs (Fire Alarm Control Panels). Features •Listed to UL standard 864, 9th edition. •On-board DACT. •Remote site or local USB port upload/download, using PS- Tools. •Four (4) Style Y (Class B) NAC circuits, which can be con- verted to four (4) Style Z (Class A) circuits with optional ZNAC-92 converter module. (Up to 6.0 amps total NAC power when using optional XRM-24B.) •Selectable strobe synchronization for System Sensor, Wheelock, and Gentex devices. •Remote Acknowledge, Silence, Reset and Drill via address- able monitor modules or LCD-80F, ANN-80 or Legacy ACS Annunciators. •ANN-BUS for connection to following optional modules (cannot be used if ACS annunciators are used): –ANN-80(-W) Remote LCD Annunciator –ANN-I/O LED Driver –ANN-S/PG Printer Module –ANN-RLY Relay Module –ANN-LED Annunciator Module –ANN-RLED Annunciator Module alarms only –ROME Relay Option Module Enclosure •ACS/TERM: –ACS Annunciators: Up to 32 Legacy ACM Series annun- ciators (ACM-16AT or ACM-32 series). Cannot be used if ANN-BUS devices are used. –Terminal-mode Annunciators: Up to 32 Legacy LCD-80F remote annunciators. Page 2 of 6 — DF-60601:A1 • 12/07/2010 •EIA-232 printer/PC interface (variable baud rate) on main circuit board, for use with optional UL-listed printer PRN-6F. •Integral 80-character LCD display with backlighting. •Real-time clock/calendar with automatic daylight savings control. •Detector sensitivity test capability (NFPA 72 compliant). •History file with 1,000-event capacity. •Maintenance alert warns when smoke detector dust accu- mulation is excessive. •Automatic device type-code verification. •One person audible or silent walk test with walk-test log and printout. •Point trouble identification. •Waterflow (nonsilenceable) selection per monitor point. •System alarm verification selection per detector point. •PAS (Positive Alarm Sequence) and presignal delay per point (NFPA 72 compliant). NOTE: Only detectors may participate in PAS. SLC LOOP: •SLC can be configured for NFPA Style 4, 6, or 7 operation. •SLC supports up to 198 addressable devices per loop (99 detectors and 99 monitor, control, or relay modules). •SLC loop maximum length 10,000 ft. (3,000 m.). See installation manual for wire tables. NOTIFICATION APPLIANCE CIRCUITS (NACS): •Four onboard NACs with additional NAC capability using output control modules (CMF-300 or CMF-300-6). The four Class B NACs can be converted to four Class A NACs with optional ZNAC-92 converter module. •Silence Inhibit and Auto Silence timer options. •Continuous, March Time, Temporal or California code for main circuit board NACs with two-stage capability. •Selectable strobe synchronization per NAC. •2.5 amps maximum per each NAC circuit. NOTE: Maximum 24VDC system power output is shared among all NAC circuits and 24VDC special-application auxiliary power outputs. Total available output is 3.0 amps. Using the optional XRM-24B transformer increases 24VDC output to 6.0 amps. PROGRAMMING AND SOFTWARE: •Autoprogram (learn mode) reduces installation time. •Custom English labels (per point) may be manually entered or selected from an internal library file. •Three Form-C relay outputs (two programmable). •99 software zones. •Continuous fire protection during online programming at the front panel. •Program Check automatically catches common errors not linked to any zone or input point. •OFFLINE PROGRAMMING: Create the entire program in your office using a Windows®-based software package (order programming kit PS-Tools, separately). Upload/ download system programming locally to the MS- 9200UDLS Rev 3 in less than one minute. •USB upload/download programming with standard Male-A to Male-B cable. User Interface LED INDICATORS •AC Power (green) •Fire Alarm (red) •Supervisory (yellow) •Alarm Silenced (yellow) •System Trouble (yellow) •Maintenance/Presignal (yellow) •Disabled (yellow) •Battery Fault (yellow) •Ground Fault (yellow) KEYPAD CONTROLS •Acknowledge/Step •Alarm Silence •Drill •System Reset (lamp test) •16-key alpha-numeric pad (similar to telephone keypad) •4 cursor keys •Enter Product Line Information MS-9200UDLS: 198-point addressable Fire Alarm Control Panel, one SLC loop. Includes 80-character LCD display, sin- gle printed circuit board mounted on chassis, and cabinet. 120 VAC operation. MS-9200UDLSE: Same as MS-9200UDLS, except with 240 VAC operation. 4XTMF Reverse Polarity Transmitter Module: Provides supervised output for local energy municipal box transmitter, alarm, and trouble. ZNAC-92: Optional converter module which converts four (4) Style Y (Class B) NAC circuits to four (4) Style Z (Class A) cir- cuits. PK-CD Programming software for Windows®-based PC com- puter (cable not included), available on www.firelite.com. DP-9692: Optional dress panel for MS-9200UDLS Rev 3. TR-CE: Optional trim Ring for semi-flush mounting. BB-26: Battery backbox, holds up to two 25 AH batteries and CHG-75. BB-55F: Battery box, houses two 55 AH batteries. CHG-75: Battery charger for lead-acid batteries with a rating of 25 to 75 AH. CHG-120F: Remote battery charging system for lead-acid bat- teries with a rating of 55 to 120 AH. Requires additional BB- 55F for mounting. BAT Series: Batteries, see data sheet DF-52397. XRM-24B(E): Optional transformer. Increases system power output to 6.0 amps. Use XRM-24BE with MS-9200UDLS Rev 3(E). PRT/PK-CABLE: Cable printer/personal computer interface cable; required for printer or for local upload/download pro- gramming and updating panel firmware. PRN-6F: UL listed compatible event printer. Uses tractor-fed paper. IPDACT-2/2UD, IPDACT Internet Monitoring Module: Mounts in bottom of enclosure with optional mounting kit (PN IPBRKT). Connects to primary and secondary DACT tele- phone output ports for internet communications over customer provided ethernet internet connection. Requires compatible Teldat VisorALARM Central Station Receiver. Can use DHCP or static IP. (See data sheet DF-60407 or DF-52424 for more information.) DF-60601:A1 • 12/07/2010 — Page 3 of 6 IPBRKT: Mounting kit for IPDACT-2/2UD in common enclo- sure. IPSPLT: Y-adaptor option allows connection of both panel dialer outputs to one IPDACT-2/2UD cable input. COMPATIBLE ANNUNCIATORS ANN-80(-W): LCD Annunciator is a remote LCD annunciator that mimics the information displayed on the FACP LCD dis- play. Recommended wire type is un-shielded. (Basic model is red; order -W version for white; see DF-52417.) ANN-LED: Annunciator Module provides three LEDs for each zone: Alarm, Trouble and Supervisory. Ships with red enclo- sure (see DF-60241). ANN-RLED: Provides alarm (red) indicators for up to 30 input zones or addressable points. (See DF-60241). ANN-RLY: Relay Module, which can be mounted inside the cabinet, provides 10 programmable Form-C relays. (See DF- 52431.) ROME: Relay Option Module Enclosure. Provides one ANN- RLY Relay Module already installed. The ROME Series pro- vides mounting space for one additional Relay Module or one addressable Multi-module. (See Installation Sheet PN 53530.) ANN-S/PG: Serial/Parallel Printer Gateway module provides a connection for a serial or parallel printer. (See DF-52429.) ANN-I/O: LED Driver Module provides connections to a user supplied graphic annunciator. (See DF-52430.) ACM-8RF: Relay module provides 8 Form-C 5.0 amp relays. ACS-LED Zone Series: LED-type fire annunciators capable of providing up to 99 software zones of annunciation. Available in increments of 16 or 32 points to meet a variety of applications. LDM Graphic Series: Lamp Driver Module series for use with custom graphic annunciators. LCD-80F (Liquid Crystal Display) point annunciator: 80-character, backlit LCD-type fire annunciators capable of displaying English-language text. NOTE: For more information on Compatible Annunciators for use with the MS-9200UDLS Rev 3, see the following data sheets (doc- ument numbers) ACM-8RF (DF-51555), ACS/ACMSeries (DF- 52378), LDM Series (DF-51384), LCD-80F (DF-52185). LITESPEED COMPATIBLE ADDRESSABLE DEVICES All feature a polling LED and rotary switches for addressing. CP355: Addressable low-profile ionization smoke detector. SD355: Addressable low-profile photoelectric smoke detector. SD355T: Addressable low-profile photoelectric smoke detec- tor with thermal sensor. SD355R: Addressable remote test capable detector for use with D355PL or DNR(W) duct smoke detector housings. H355: Fast-response, low-profile heat detector. H355R: Fast-response, low-profile heat detector with rate-of- rise option. H355HT: Fixed high-temperature detector that activates at 190F/88C. AD355(A): Low-profile, intelligent, “Adapt” multi-sensor detec- tor (B350LP base included). BEAM355: Intelligent beam smoke detector. BEAM355S: Intelligent beam smoke detector with integral sensitivity test. D355PL: Innovair Flex low-flow non-relay duct-detector hous- ing. SD355R included. DNRW: Innovair Flex low-flow non-relay duct-detector hous- ing, with NEMA-4 rating. Watertight. (Order SD355R sepa- rately.) MMF-300: Addressable Monitor Module for one zone of nor- mally-open dry-contact initiating devices. Mounts in standard 4.0" (10.16 cm.) box. Includes plastic cover plate and end-of- line resistor. Module may be configured for either a Style B (Class B) or Style D (Class A) IDC. MDF-300: Dual Monitor Module. Same as MMF-300 except it provides two Style B (Class B) only IDCs. MMF-301: Miniature version of MMF-300. Excludes LED and Style D option. Connects with wire pigtails. May mount in device backbox. MMF-302: Similar to MMF-300, but may monitor up to 20 con- ventional two-wire detectors. Requires resettable 24 VDC power. Consult factory for compatible smoke detectors. Page 4 of 6 — DF-60601:A1 • 12/07/2010 CMF-300: Addressable Control Module for one Style Y/Z (Class B/A) zone of supervised polarized Notification Appli- ances. Mounts directly to a 4.0" (10.16 cm.) electrical box. Notification Appliance Circuit option requires external 24 VDC to power notification appliances. CRF-300: Addressable relay module containing two isolated sets of Form-C contacts, which operate as a DPDT switch. Mounts directly to a 4.0" (10.16 cm.) box, surface mount using the SMB500. BG-12LX: Addressable manual pull station with interface mod- ule mounted inside. I300: Fault Isolator Module. This module isolates the SLC loop from short circuit conditions (required for Style 6 or 7 opera- tion). SMB500: Used to mount all modules except the MMF-301 and M301. MMF-300-10: Ten-input monitor module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six mod- ules on a CHS-6 chassis in a BB-6F. MMF-302-6: Six-zone interface module for compatible conven- tional two-wire detectors. Mount one or two modules in a BB- 2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F. CMF-300-6: Six-circuit supervised control module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F. CRF-300-6: Six Form-C relay control module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F. NOTE: 1)For more information on Compatible Addressable Devices for use with the MS-9200UDLS Rev 3, see the following data sheets (document numbers): AD355 (DF-52324), BG-12LX (DF-52013), CMF-300-6 (DF-52365), CRF-300-6 (DF-60379), CMF/CRF Series (DF-52130), CP355 (DF-52383), D355PL (DF- 52398), H355 Series (DF-52385), I300 (DF-52389), MMF-300 Series/MDF-300 (DF-52121), MMF-300-10 (DF-52347), MMF- 302-6 (DF-52356), SD355/SD355T (DF-52384). 2)Legacy 300 Series detection devices such as the CP300/CP350, SD300(T)/ SD350(T) and older modules such as the M300, M301, M302, C304, and BG-10LX are not compatible with LiteSpeed polling. If the SLC contains one of these devices, polling must be set for standard LiteSpeed protocol. Please consult factory for further information on previous 300 Series devices. Wiring Requirements While shielded wire is not required, it is recommended that all SLC wiring be twisted-pair to minimize the effects of electrical interference. Wire size should be no smaller than 18 AWG (0.78 mm²) and no larger than 12 AWG (3.1 mm²). The wire size depends on the length of the SLC circuit. Refer to the panel manual for wiring details. () DF-60601:A1 • 12/07/2010 — Page 5 of 6 Page 6 of 6 — DF-60601:A1 • 12/07/2010 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Fire•Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Made in the U.S. A. System Capacity •Intelligent Signalling Line Circuits.......................................1 •Addressable device capacity..........................................198 •Programmable software zones.........................................99 •ACS Annunciators............................................................32 •ANN-bus devices..............................................................16 Electrical Specifications AC Power: MS-9200UDLS Rev 3: 120 VAC, 60 Hz, 3.0 amps. MS-9200UDLS Rev 3E: 240 VAC, 5 0 Hz, 1.5 amps. Wire size: minimum 14 AWG (2.00 mm²) with 600 V insulation. Battery charger capacity: 7 AH - 18 AH batteries. Up to two 18 Ah batteries can be housed in the FACP cabinet. Larger batteries require an external battery charger such as the CHG- 75 or CHG-120, and a separate battery cabinet such as the BB-26 or NFS-LBB. Communication Loop: Supervised and power-limited. Notification Appliance Circuits: Each terminal block pro- vides connections for two Style Y (Class B) for a total of four Style Y (Class B) or with an optional ZNAC-92 module con- verts to four Style Z (Class A) NACs. Maximum signaling cur- rent per circuit: 2.5 amps. End-of-Line Resistor: 4.7K ohm, 1/2 watt (P/N 71252 UL listed) for Style Y (Class B) NAC. Refer to panel documentation and Fire•Lite Device Compatibility Docu- ment for listed compatible devices. Two Programmable Relays and One Fixed Trouble Relay: Contact rating: 2.0 amps @ 30 VDC (resistive), 0.5 amps @ 30 VAC (resistive). Form-C relays. Special Application Non-resettable Power (24 VDC Nomi- nal): Jumper selectable (JP4) for conversion to resettable power output. Up to 1.0 amp total DC current available from each output. Power-limited. Special Application Resettable Power (24 VDC nominal): Jumper selectable (JP6) for conversion to non-resettable power. Up to 1.0 amp total DC current available. Refer to the Fire•Lite Device Compatibility Document for listed compatible devices. Remote Sync Output: Remote power supply synchronization output. Nominal special application power: 24 VDC. Maximum current: 300 mA. End-of-Line Resistor: 4.7K ohm. Output linked to NAC 1 control. Supervised and power-limited. Telephone Interface: Unless used with Teldat VISORALARM, requires dedicated business telephone number with a mini- mum of 5 volts DC (off-hook voltage). Obtain dedicated phone line directly from your local phone company. Do not use shared phone lines or PBX (digital) type phone line extensions. Cabinet Specifications Door: 19.26" (48.92 cm.) high x 16.82" (42.73 cm.) wide x 0.12" (.30 cm.) deep. Backbox: 19.00" (48.26 cm.) high x 16.65" (42.29 cm.) wide x 5.20" (13.34 cm.) deep. Trim Ring (TR-CE): 22.00" (55.88 cm.) high x 19.65" (49.91 cm.) wide. Shipping Specifications Weight: 26.9 lbs. (12.20 kg.) Dimensions: 20.00” (50.80 cm.) high x 22.5” (57.15 cm.) wide x 8.5” (21.59 cm.) deep. Temperature and Humidity Ranges This system meets NFPA requirements for operation at 0 – 49°C/32 – 120°F and at a relative humidity 93% ± 2% RH (noncondensing) at 32°C ± 2°C (90°F ± 3°F). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme tempera- ture ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15 – 27°C/60 – 80°F. NFPA Standards The MS-9200UDLS Rev 3 complies with the following NFPA 72 Fire Alarm Systems requirements: –LOCAL (Automatic, Manual, Waterflow and Sprinkler Supervisory). –AUXILIARY (Automatic, Manual and Waterflow) (requires 4XTMF). –REMOTE STATION (Automatic, Manual, Waterflow and Sprinkler Supervisory) (Where a DACT is not accepted, the alarm, trouble and supervisory relays may be con- nected to UL 864 listed transmitters. For reverse polarity signaling of alarm and trouble, 4XTMF is required.) –PROPRIETARY (Automatic, Manual, Waterflow and Sprinkler Supervisory). –CENTRAL STATION (Automatic, Manual, Waterflow and Sprinkler Supervisory). –OT, PSDN (Other Technologies, Packet-switched Data Network) Agency Listings and Approvals The listings and approvals below apply to the basic MS- 9200UDLS Rev 3 control panel. In some cases, certain mod- ules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. •UL Listed: S624 •FM approved •CSFM: 7165-0075:0208 •MEA: 120-06-E For ULC-listed version, see DF-60599. FireLite® Alarms® is a registered trademark of Honeywell International Inc. Wheelock® is a registered trademark of and Exceder™ is a trademark of Cooper Notification. ©2010 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. SYSTEM SPECIFICATIONS