Loading...
HomeMy WebLinkAboutDRB110188 conceptual plans boiler_121611I i I i i 1 �I { 1 i 1 �I 1 1 1 i �l I i i i e l I i iI 1 t �I i i Ii i i . r r r 1 r , r r r r r r r r , r r r r %r , 1 fr /r Af If i i If i s/ r i r MARY HART DESIGN land planning a landscape architecture; post office box 8258 p. 970- 389 -3583 breckenridge Colorado 80424 maryhandesign @gmail.com Site Plan L'ionshead Concert Hall Plaza Vail, Colorado TOW Scale: 1'= 10' Date: 11.7.11 z 0 N ro V U O J 0 W 0 01 Q�J O J www CnCn = V ~ U O goo O w U W 0 X r w dL N I PREFINISHED CEE -LOCK METAL ROOF PANEL ON SHEET MEMBRANE WATERPROOFING PANEL PAN AROUND EAVE FLASHING MTL DRIP FLASHING 43/4 "x6" MTL GUTTER- 3" DIA MTL DOWNSPOUT 2x10 STAINED CEDAR FASCIA TRIM 1x6 T &G V- GROOVE DECKING SOFFIT 1x6 STAINED CEDAR (CAP TRIM) 1' UON (RE: ROOF PLAN) EXT. STAINED CEDAR BOARD & BATT WALL H12SCALE: ARDWARE MOUNTING 1 JTYP. HINGE B ATT INSULATION 5/8" TYPE "X" GYPSUM WALLBOARD (2) 2x6 WOOD HEADER EXTERIOR SIDE 2x4 STAINED CEDAR WOOD TRIM SEALANT & BACKER ROD WEATHER BARRIER SHIM AS REQUIRED 6 )/2 „ 10 HM DOOR HEAD SCALE: 3" = 1' -0" NTERIOR SIDE n, O z_ S PLAN GRID I SECTION INTERIOR SIDE PLAN 61 INTERIOR SIDE EXTERIOR SIDE 91 HR. RATED EXT. WALL SCALE: 1 z" = 1' -0" 5:12 ROOF PITCH T.O. WALL /BEARING ELEV. 60' -1 1/2" NOTCH RAFTER AS REQUIRED FOR STUD WALL (RE: STRUCT.) BATT INSULATION EXTERIOR CLADDING, SEE ELEVATIONS NOTE: EXTERIOR VENEER NOT INCLUDED IN WALL THICKNESS FIRESTOPPING )R SIDE 5/8" TYPE "X" GYPSUM WALLBOARD 5/8" TYPE "X" GYPSUM WALLBOARD 2X6 WOOD STUD BATT INSULATION 5/8" TYPE "X" GYPSUM WALLBOARD EXTERIOR CLADDING, SEE ELEVATIONS NOTE: EXTERIOR VENEER NOT INCLUDED IN WALL THICKNESS 5/8" GYPSUM WALL BOARD THERMAL BARRIER CONFORMING WITH 2003 IBC SECTION 2603 NOTE: 1. SEE OTHER METAL ROOF DETAILS FOR ADDITIONAL INFORMATION. 8 ROOF OVERHANG - BOILER BUILDING SCALE: 1" = 1' -0" 2" PLAN VIEW THEIR BARRIER 3/8" THICK STAINED CEDAR PLYWOOD BD. 1x4 STAINED CEDAR BATT V -0" O.C. (TYP.) ELEVATION 6 BOARD & BATT SIDING - BOILER BUILDING SCALE: 1 2' SNOW SCREEN BERRIDGE CEE -LOCK RIDGE CLOSURE FASTENERS BY METAL ROOF MFR CLOSED -CELL I PREFINISHED METAL POLYURETHANE INSULATION CEE -LOCK ROOF PANEL (6" THICK) ROOF SHEATHING BLOCKING AS REQUIRED (RE: STRUCT.) BETWEEN ROOF JOISTS SHEET MEMBRANE WATERPROOFING 5/8" GYPSUM WALL BOARD THERMAL BARRIER CONFORMING WITH 2003 IBC SECTION 2603 4x10 RIDGE BEAM (RE: STRUCT) 5METAL ROOF RIDGE - BOILER BUILDING SCALE: 1" = 1' -0" GRID $" THICK STAINED CEDAR PLY BOARD 1x4 STAINED CEDAR BATT $" TYPE "X" GYPSUM WALLBOARD SLOPE "' /FT. TO DRAIN MTL FLASHING SET IN BED OF SEALANT 1/8" TYPE "X„ YPSUM WALLBOARD ATT INSULATION x6 WOOD STUD HIM AS REQUIRED EXTERIOR SIDE /8" TYPE "X" YPSUM WALLBOARD IEATHER BARRIER EALANT & BACKER OD —x4 STAINED CEDAR WOOD TRIM EXTERIOR CLADDING, SEE ELEVATIONS NOTE: EXTERIOR VENEER NOT INCLUDED IN WALL THICKNESS 7 HM DOOR JAMB SCALE: 3" = 1' -0" SNOW -MELT BOILER ROOM 2x6 STUD WALL W /5" BATT INSULATION — (RE: PLAN) 5/8" TYPE "X" GYPSUM WALLBOARD 1x8 STAINED CEDAR TRIM EJ W /BACKER ROD & SEALANT, TYP -\ DITCH SLAB TO FLOOR DRAIN (RE: FLOOR PLAN) FF SLAB @ PERIMETER IL 8151' -6" a a CONCRETE SLAB - (RE: STRUCT.) U w PRECAST CONC. CAP I 4X SPLIT -FACED CMU WALL AIR BARRIER FLEXIBLE FLASHING 2" (MIN.) ABUTTING LANDSCAPE 2" ABUTTING SIDEWALK @ DOOR L i L F _ FINISH GRADE 4 a — — - EL= VARIES a = I F (RE: CIVIL) —1 11 -111 =1 11= LANDSCAPE TREATMENT a (RE: LANDSCAPE) CONCRETE FOUNDATION I ° W /TURNED -IN FOOTING a (RE: STRUCT.) RE: STgLICT. a a WATERPROOFING MEMBRANE & DRAINAGE SYSTEM w /BOARD INSULATION I 4 WALL SECTION - BOILER BUILDING SCALE: 1"=1'-O" 3" DIA PREFINISHED MTL. DOWNSPOUT 3" DIA PREFINISHED MTL. DOWNSPOUT 2 3RCP PLAN - BOILER BUILDING S SCALE :: z" (2) 4' L. FLOURESCENT LIGHT FIXTURES (RE: ELEC.) EXTERIOR BOARD & BATT WALL 1x6 T &G V— GROOVE DECKING SOFFIT 4x10 ROOF RIDGE BEAM -1x6 STAINED CEDAR (CAP TRIM) 5/8" GYPSUM WALL BOARD THERMAL BARRIER CONFORMING WITH 2003 IBC SECTION 2603 2x8 ROOF RAFTERS BEHIND GWB @ 16" O.0 (DASHED) (RE:STRUCT.) 2x10 STAINED CEDAR FASCIA TRIM -PRE— FINISHED METAL GUTTER \—BERRIDGE CEE —LOCK RIDGE CLOSURE PREFINISHED METAL CEE —LOCK ROOF PANE METAL SNOW GUARD ELECTRIC SNOWMELT © EAVE PRE — FINISHED METAL GUTTER 3" DIA PREFINISHED MTL. DOWNSPOUT 2 ROOF PLAN - BOILER BUILDING 2 SCALE: ' = 1' -0" 1FLOOR PLAN - BOILER BUILDING SCALE: z” = 1' -0" 'E "X" GYPSUM IOARD IOR BOARD & WALL OF ROOF E— DASHED) OF PRECAST CAP HOLLOW METAL W /BACKER Sc SEALANT o� I I 0 " O.D. THROUGH (RE: MEP) IIART DESIC -N DEPT. OF PUBLIC WORKS 1309 ELKHORN DRIVE VAIL, CO 81632 I I t: 970.479.2158 CIVIL ENGINEER BOILER FL.UE ROOF EDWARDS, CO 81632 t: 970.926.3373 ARCHITECT PO BOX 8258 BRECKENRIDGE, CO 80424 t: 970.453.5878 ARCHITECT 4240 ARCHITECTURE INC 3507 RINGSBY CT, STE 117 DENVER, CO 80216 I I t: 303.292.3388 ENGINEER 110 E. BEAVER CRK BLVD. STE 202 AVON, CO 81620 t: 970.949.6108 I I 1169 HILLTOP PKWY STE 206A STEAMBOAT, CO 80487 t: 970.846.7970 IRRIGATION DESIGNER CONSULTING & ENG P.O. BOX 2117 MILLS, WY 82644 t: 307.315.8054 co N cz N co O U (2) 4' L. FLOURESCENT LIGHT FIXTURES (RE: ELEC.) EXTERIOR BOARD & BATT WALL 1x6 T &G V— GROOVE DECKING SOFFIT 4x10 ROOF RIDGE BEAM -1x6 STAINED CEDAR (CAP TRIM) 5/8" GYPSUM WALL BOARD THERMAL BARRIER CONFORMING WITH 2003 IBC SECTION 2603 2x8 ROOF RAFTERS BEHIND GWB @ 16" O.0 (DASHED) (RE:STRUCT.) 2x10 STAINED CEDAR FASCIA TRIM -PRE— FINISHED METAL GUTTER \—BERRIDGE CEE —LOCK RIDGE CLOSURE PREFINISHED METAL CEE —LOCK ROOF PANE METAL SNOW GUARD ELECTRIC SNOWMELT © EAVE PRE — FINISHED METAL GUTTER 3" DIA PREFINISHED MTL. DOWNSPOUT 2 ROOF PLAN - BOILER BUILDING 2 SCALE: ' = 1' -0" 1FLOOR PLAN - BOILER BUILDING SCALE: z” = 1' -0" 'E "X" GYPSUM IOARD IOR BOARD & WALL OF ROOF E— DASHED) OF PRECAST CAP HOLLOW METAL W /BACKER Sc SEALANT o� NOT FOR CONSTRUCTION MARY IIART DESIC -N DEPT. OF PUBLIC WORKS 1309 ELKHORN DRIVE VAIL, CO 81632 t: 970.479.2158 CIVIL ENGINEER 34510 U.S. 6 UNIT A -9 EDWARDS, CO 81632 t: 970.926.3373 ARCHITECT PO BOX 8258 BRECKENRIDGE, CO 80424 t: 970.453.5878 ARCHITECT 4240 ARCHITECTURE INC 3507 RINGSBY CT, STE 117 DENVER, CO 80216 t: 303.292.3388 ENGINEER 110 E. BEAVER CRK BLVD. STE 202 AVON, CO 81620 t: 970.949.6108 bIKUCIUKAL ENGINEER 1169 HILLTOP PKWY STE 206A STEAMBOAT, CO 80487 t: 970.846.7970 IRRIGATION DESIGNER CONSULTING & ENG P.O. BOX 2117 MILLS, WY 82644 t: 307.315.8054 co N cz N co O U co U ° -+--a O CU V CIO R E V I S 1 0 N S NO. 1 Oct. 24, 2011 DRB Final Submission 2 Nov. 07, 2011 DD Pricing Set 3 Dec. 02, 2011 60% CD Pricing Set D R A W I N G T I T L E Boiler Bldg. Plans & Details D R A W I N G N 0 A�l OOB B OL RIDGE CAP _ 8162' -7" BOILER FLUE (RE: MEP) BERRIDGE CEE -LOCK A RIDGE CLOSURE PREFINISHED METAL CEE -LOCK ROOF PANEL METAL SNOW GUARD PRE - FINISHED METAL GUTTER 200 STAINED CEDAR FASCIA TRIM 1x6 STAINED CEDAR (CAP TRIM) 3" DIA PREFINISHED MTL. DOWNSPOUT 1x4 STAINED CEDAR (TRIM PIECE) EXTERIOR STAINED CEDAR BOARD & BATT WALL COMBUSTION AIR DUCT (RE: MEP) 1x4 STAINED CEDAR (BASE TRIM) PRECAST CONCRETE CAP SPLIT -FACED CMU WALL FLEXIBLE FLASHING FINISH GRADE (RE: CIVIL) CONNECT DOWNSPOUTS —TO DRAIN PIPE BELOW (RE: CIVIL) 4 NW ELEVATION - SHELTER SCALE: 2' = V -0" h RIDGE CAP 8162' -7" METAL SNOW GUARD 8160' -2" 8155' -1" 8151' -6" BERRIDGE CEE -LOCK RIDGE CLOSURE A 4 A1006 B PREFINISHED METAL CEE -LOCK ROOF PANEL PRE - FINISHED METAL GUTTER 2x10 STAINED CEDAR FASCIA TRIM 1x6 STAINED CEDAR (CAP TRIM) EXTERIOR STAINED CEDAR BOARD & BATT WALL 1x4 STAINED CEDAR (TRIM PIECE) 1x4 STAINED CEDAR (BASE TRIM) PRECAST CONCRETE CAP SPLIT -FACED CMU WALL BLE FLASHING FINISH GRADE (RE: CIVIL) 2 S ELEVATION - BOILER BUILDING SCALE: 2' = V -0" 4 A1 00B 3 NE ELEVATION - SHELTER SCALE: z" = 1' -0" D JSW ELEVATION - BOILER BUILDING SCALE: z" = 1' -0" : NOT FOR CONSTRUCTION BOILER FLUE BOILER FLUE OWNER a_ 1309 ELKHORN DRIVE VAIL, CO 81632 (RE: MEP) (RE: MEP) 34510 U.S. 6 UNIT A -9 Uj EDWARDS, CO 81632 S jIf1 5,8 LANDSCAPE ARCHITECT MARY HART DESIGN LLC PO BOX 8258 BRECKENRIDGE, CO 80424 t: 970.453.5878 Z 5,8 3507 RINGSBY CT, STE 117 A100B DENVER, CO 80216 FLUE STORM COLLAR & MEP ENGINEER A100B 2 BERRIDGE CEE -LOCK t: 970.949.6108 STRUCTURAL ENGINEER 1169 HILLTOP PKWY FLASHING (RE: MEP) STE 206A STEAMBOAT, CO 80487 t: 970.846.7970 DESIGNER BERRIDGE CEE -LOCK RIDGE CLOSURE P.O. BOX 2117 MILLS, WY 82644 t: 307.315.8054 OIL WALL CAP N ICU RIDGE CLOSURE Cz N 8162' -7" U PREFINISHED METAL I (3) U ° _4_a C/) O co 0 CEE -LOCK ROOF PANEL CIO R E V I S 1 0 N S N0. 1 Oct. 24, 2011 DRIB Final Submission 2 Nov. 07, 2011 DD Pricing Set 3 Dec. 02, 2011 60% CD Pricing Set DRAWING T I T L E: Boiler Bldg. ■ Elevations D R A W I N G N 0 : A�200B PREFINISHED METAL CEE -LOCK ROOF PANEL METAL SNOW GUARD ROOF EAVE ELECTRIC SNOWMELT 8160' -2" O EAVE (RE: ELEC.) R3 PRE - FINISHED METAL PRE - FINISHED METAL GUTTER GUTTER DIA PREFINISHED 3" DIA PREFINISHED 2x10 STAINED CEDAR 2x10 STAINED CEDAR MTL. DOWNSPOUT MTL. DOWNSPOUT FASCIA TRIM FASCIA TRIM LIGHT SCONCE ` 1x6 STAINED CEDAR 1x6 STAINED (RE: ELEC.) ❑ ' „ CAPCTRIM) 3 -0 2x6 STAINED CEDAR EXTERIOR STAINED EXTERIOR STAINED \ LINTEL CEDAR BOARD & CEDAR BOARD & 1x4 STAINED CEDAR BATT WALL FAN BATT WALL (TRIM PIECE) 1x4 STAINED CEDAR WALL CAP (RE: MEP) \ 2x4 STAINED CEDAR (TRIM PIECE) DOOR TRIM 1x4 STAINED CEDAR 1x4 STAINED CEDAR (BASE TRIM) WALL CAP WALL CAP o > (BASE TRIM) 8155'- 1 ' 8155'-l” I PRECAST CONCRETE PRECAST CONCRETE i- CAP CAP ; ...:.• ,.. ..: .., , ....: :.: � ....... .. :..... .. .... .. ,. ... ... �: �. - SPLIT - FACED CMU _ : ...:...:.. SPLIT FACED CMU ; .. :: ... ; . 3'x7' HOLLOW METAL WALL I - DOOR WITH ... ;, .•...:.:.. .:..., ,. ... - :..:.: , . .:; ..` i� KICKPLATE BOTH FLEXIBLE FLASHING .... - ::.. , . •... .:,: ..... .: ..:. ., .. ........ , . ....::.:..:. . :: .. ,. FINISH GRADE ... : � SIDEWALK PAVING RE. CIVIL)f. UL E. LANDSCAPE) (R E) FF LEVEL FF LEVEL 8151' -6" 8151' -6" 4 A1 00B 3 NE ELEVATION - SHELTER SCALE: z" = 1' -0" D JSW ELEVATION - BOILER BUILDING SCALE: z" = 1' -0" : NOT FOR CONSTRUCTION iv1 -ARY I IART DL_SIt'_N OWNER TOWN OF VAIL DEPT. OF PUBLIC WORKS 1309 ELKHORN DRIVE VAIL, CO 81632 t: 970.479.2158 CIVIL ENGINEER 34510 U.S. 6 UNIT A -9 EDWARDS, CO 81632 t: 970.926.3373 LANDSCAPE ARCHITECT MARY HART DESIGN LLC PO BOX 8258 BRECKENRIDGE, CO 80424 t: 970.453.5878 3507 RINGSBY CT, STE 117 DENVER, CO 80216 t: 303.292.3388 MEP ENGINEER 110 E. BEAVER CRK BLVD. STE 202 AVON, CO 81620 t: 970.949.6108 STRUCTURAL ENGINEER 1169 HILLTOP PKWY STE 206A STEAMBOAT, CO 80487 t: 970.846.7970 DESIGNER CONSULTING & ENG P.O. BOX 2117 MILLS, WY 82644 t: 307.315.8054 ICU N ICU Cz N U c (3) U ° _4_a C/) O co 0 CIO R E V I S 1 0 N S N0. 1 Oct. 24, 2011 DRIB Final Submission 2 Nov. 07, 2011 DD Pricing Set 3 Dec. 02, 2011 60% CD Pricing Set DRAWING T I T L E: Boiler Bldg. ■ Elevations D R A W I N G N 0 : A�200B