Loading...
HomeMy WebLinkAboutDRB110188 conceptual plans boier_121911I i I i i 1 �I { 1 i 1 �I 1 1 1 i �l I i i i e l I i iI 1 t �I i i Ii i i . r r r 1 r , r r r r r r r r , r r r r %r , 1 fr /r Af If i i If i s/ r i r MARY HART DESIGN land planning a landscape architecture; post office box 8258 p. 970- 389 -3583 breckenridge Colorado 80424 maryhandesign @gmail.com Site Plan L'ionshead Concert Hall Plaza Vail, Colorado TOW Scale: 1'= 10' Date: 11.7.11 z 0 N Y U O w 0 O 1 �J O J www Cf)W = V ry ~ U O goo w U w 0 H X r w dL. N I PREFINISHED CEE -LOCK METAL ROOF PANEL ON SHEET MEMBRANE WATERPROOFING PANEL PAN AROUND EAVE FLASHING MTL DRIP FLASHING 43/4 "x6" MTL GUTTER- 3" DIA MTL DOWNSPOUT 2x10 STAINED CEDAR FASCIA TRIM — 1 x6 T &G V- GROOVE DECKING SOFFIT 1x6 STAINED CEDAR (CAP TRIM) 1' UON (RE: ROOF PLAN) EXT. STAINED CEDAR BOARD & BATT WALL H12SCALE: ARDWARE MOUNTING 1 JTYP. HINGE B ATT INSULATION 5/8" TYPE "X" GYPSUM WALLBOARD (2) 2x6 WOOD HEADER EXTERIOR SIDE 2x4 STAINED CEDAR WOOD TRIM SEALANT & BACKER ROD WEATHER BARRIER SHIM AS REQUIRED 6Y2„ 10 HM DOOR HEAD SCALE: 3" = V -0" NTERIOR SIDE c� Z_ S PLAN Sc SECTION INTERIOR SIDE PLAN 61„ 2 INTERIOR SIDE EXTERIOR SIDE 91 HR. RATED EXT. WALL SCALE: 1 z" = 1' -0" GRID 5:12 ROOF PITCH I T.O. WALL /BEARING ELEV. 60' -1 1/2" NOTCH RAFTER AS REQUIRED FOR STUD WALL (RE: STRUCT.) BATT INSULATION EXTERIOR CLADDING, SEE ELEVATIONS NOTE: EXTERIOR VENEER NOT INCLUDED IN WALL THICKNESS FIRESTOPPING )R SIDE 5/8" TYPE "X" GYPSUM WALLBOARD 5/8" TYPE "X" GYPSUM WALLBOARD 2X6 WOOD STUD BATT INSULATION 5/8" TYPE "X" GYPSUM WALLBOARD EXTERIOR CLADDING, SEE ELEVATIONS NOTE: EXTERIOR VENEER NOT INCLUDED IN WALL THICKNESS 5/8" GYPSUM WALL BOARD THERMAL BARRIER CONFORMING WITH 2003 IBC SECTION 2603 NOTE: 1. SEE OTHER METAL ROOF DETAILS FOR ADDITIONAL INFORMATION. 8 ROOF OVERHANG - BOILER BUILDING SCALE: 1" = V -0" 2" �E 1/8" TYPE "X„ YPSUM WALLBOARD ATT INSULATION x6 WOOD STUD HIM AS REQUIRED EXTERIOR SIDE /8" TYPE "X" YPSUM WALLBOARD FEATHER BARRIER EALANT & BACKER OD —x4 STAINED CEDAR WOOD TRIM EXTERIOR CLADDING, SEE ELEVATIONS NOTE: EXTERIOR VENEER NOT INCLUDED IN WALL THICKNESS 7 HM DOORJAMB SCALE: 3" = V -0" PLAN VIEW THEIR BARRIER 3/8" THICK STAINED CEDAR PLYWOOD BD. 1x4 STAINED CEDAR BATT V -0" O.C. (TYP.) ELEVATION 6 BOARD & BATT SIDING - BOILER BUILDING SCALE: 1 2' = V -0" SNOW SCREEN BERRIDGE CEE -LOCK FASTENERS BY METAL ROOF RIDGE CLOSURE MFR CLOSED -CELL I PREFINISHED METAL POLYURETHANE INSULATION CEE -LOCK ROOF PANEL (6" THICK) ROOF SHEATHING BLOCKING AS REQUIRED (RE: STRUCT.) BETWEEN ROOF JOISTS SHEET MEMBRANE WATERPROOFING ^o` 5/8" GYPSUM WALL BOARD THERMAL BARRIER CONFORMING WITH 2003 IBC SECTION 2603 4x10 RIDGE BEAM (RE: STRUCT) 5 METAL ROOF RIDGE - BOILER BUILDING SCALE: 1" = V -0" SNOW -MELT BOILER ROOM 2x6 STUD WALL W /5" BATT INSULATION — (RE: PLAN) 5/8" TYPE "X" GYPSUM WALLBOARD 1x8 STAINED CEDAR TRIM EJ W /BACKER ROD & SEALANT, TYP DITCH SLAB TO FLOOR DRAIN (RE: FLOOR PLAN) FF SLAB @ PERIMETER IL 8151' -6" a a CONCRETE SLAB - (RE: STRUCT.) U Of F— w GRID ji 1 Q °I I 8" THICK STAINED CEDAR PLY BOARD 1x4 STAINED CEDAR BATT 8 51, TYPE "X" GYPSUM WALLBOARD SLOPE "' /FT. TO DRAIN MTL FLASHING SET IN BED OF SEALANT PRECAST CONC. CAP 4X SPLIT -FACED CMU WALL FAIR BARRIER FLEXIBLE FLASHING 2" (MIN.) ABUTTING LANDSCAPE 2" ABUTTING SIDEWALK @ DOOR FINISH GRADE 7LI (REL= VARIES 1111t E: CIVIL) LANDSCAPE TREATMENT (RE: LANDSCAPE) CONCRETE FOUNDATION W /TURNED -IN FOOTING a , (RE: STRUCT.) RE: T ?UCT. a a WATERPROOFING MEMBRANE & DRAINAGE SYSTEM w /BOARD INSULATION I 4 WALL SECTION - BOILER BUILDING SCALE: 1" = V -0" 3" DIA PREFINISHED MTL. DOWNSPOUT 3" DIA PREFINISHED MTL. DOWNSPOUT 2 3RCP PLAN - BOILER BUILDING S CALE :: z" = 1' -0" S 5,e'1 �\ (2) 4' L. FLOURESCENT LIGHT FIXTURES (RE: ELEC.) EXTERIOR BOARD & BATT WALL 1x6 T &G V— GROOVE DECKING SOFFIT 4x10 ROOF RIDGE BEAM -1x6 STAINED CEDAR (CAP TRIM) 5/8" GYPSUM WALL BOARD THERMAL BARRIER CONFORMING WITH 2003 IBC SECTION 2603 2x8 ROOF RAFTERS BEHIND GWB CAD 16" O.0 (DASHED) (RE:STRUCT.) 2x10 STAINED CEDAR FASCIA TRIM -PRE— FINISHED METAL GUTTER \—BERRIDGE CEE —LOCK RIDGE CLOSURE PREFINISHED METAL CEE —LOCK ROOF PANE METAL SNOW GUARD ELECTRIC SNOWMELT EAVE PRE — FINISHED METAL GUTTER 3" DIA PREFINISHED MTL. DOWNSPOUT 2 ROOF PLAN - BOILER BUILDING SCALE: 2' = 1' -0" 1FLOOR PLAN - BOILER BUILDING SCALE: 2' = 1' -0" 'E "X" GYPSUM IOARD IOR BOARD & WALL OF ROOF E— DASHED) OF PRECAST CAP HOLLOW METAL W /BACKER 3c SEALANT � o�' 9 I I CONSTRUCTION " O.D. THROUGH (RE: MEP) I IART DL-SI�N DEPT. OF PUBLIC WORKS 1309 ELKHORN DRIVE VAIL, CO 81632 I I t: 970.479.2158 CIVIL ENGINEER BOILER FLUE ROOF EDWARDS, CO 81632 t: 970.926.3373 ARCHITECT PO BOX 8258 BRECKENRIDGE, CO 80424 t: 970.453.5878 ARCHITECT 4240 ARCHITECTURE INC 3507 RINGSBY CT, STE 117 DENVER, CO 80216 I I t: 303.292.3388 ENGINEER 110 E. BEAVER CRK BLVD. STE 202 AVON, CO 81620 t: 970.949.6108 I I 1169 HILLTOP PKWY STE 206A STEAMBOAT, CO 80487 t: 970.846.7970 IRRIGATION DESIGNER CONSULTING & ENG P.O. BOX 2117 MILLS, WY 82644 t: 307.315.8054 N cz N co O U (2) 4' L. FLOURESCENT LIGHT FIXTURES (RE: ELEC.) EXTERIOR BOARD & BATT WALL 1x6 T &G V— GROOVE DECKING SOFFIT 4x10 ROOF RIDGE BEAM -1x6 STAINED CEDAR (CAP TRIM) 5/8" GYPSUM WALL BOARD THERMAL BARRIER CONFORMING WITH 2003 IBC SECTION 2603 2x8 ROOF RAFTERS BEHIND GWB CAD 16" O.0 (DASHED) (RE:STRUCT.) 2x10 STAINED CEDAR FASCIA TRIM -PRE— FINISHED METAL GUTTER \—BERRIDGE CEE —LOCK RIDGE CLOSURE PREFINISHED METAL CEE —LOCK ROOF PANE METAL SNOW GUARD ELECTRIC SNOWMELT EAVE PRE — FINISHED METAL GUTTER 3" DIA PREFINISHED MTL. DOWNSPOUT 2 ROOF PLAN - BOILER BUILDING SCALE: 2' = 1' -0" 1FLOOR PLAN - BOILER BUILDING SCALE: 2' = 1' -0" 'E "X" GYPSUM IOARD IOR BOARD & WALL OF ROOF E— DASHED) OF PRECAST CAP HOLLOW METAL W /BACKER 3c SEALANT � o�' 9 NOT FOR CONSTRUCTION MARY I IART DL-SI�N DEPT. OF PUBLIC WORKS 1309 ELKHORN DRIVE VAIL, CO 81632 t: 970.479.2158 CIVIL ENGINEER 34510 U.S. 6 UNIT A -9 EDWARDS, CO 81632 t: 970.926.3373 ARCHITECT PO BOX 8258 BRECKENRIDGE, CO 80424 t: 970.453.5878 ARCHITECT 4240 ARCHITECTURE INC 3507 RINGSBY CT, STE 117 DENVER, CO 80216 t: 303.292.3388 ENGINEER 110 E. BEAVER CRK BLVD. STE 202 AVON, CO 81620 t: 970.949.6108 bIKUUIUKAL ENGINEER 1169 HILLTOP PKWY STE 206A STEAMBOAT, CO 80487 t: 970.846.7970 IRRIGATION DESIGNER CONSULTING & ENG P.O. BOX 2117 MILLS, WY 82644 t: 307.315.8054 N cz N co O U co > CU L. . CU (D > U ° Cn O o V (z R E V I S 1 0 N S NO. 1 Oct. 24, 2011 DRIB Final Submission 2 Nov. 07, 2011 DD Pricing Set 3 Dec. 02, 2011 60% CD Pricing Set D R A W I N G T I T L E Boiler Bldg. Plans & Details D R A W I N G N 0 Aml OOB BOILER FLUE (RE: MEP) B BERRIDGE CEE —LOCK A OL RIDGE CAP RIDGE CLOSURE 8162' -7" WALL CAP 8155' -1" FF LEVEL 8151' -6" PREFINISHED METAL CEE —LOCK ROOF PANEL METAL SNOW GUARD PRE — FINISHED METAL GUTTER 2x10 STAINED CEDAR FASCIA TRIM 1x6 STAINED CEDAR (CAP TRIM) 3" DIA PREFINISHED MTL. DOWNSPOUT 1x4 STAINED CEDAR (TRIM PIECE) EXTERIOR STAINED CEDAR BOARD & BATT WALL COMBUSTION AIR DUCT (RE: MEP) 1x4 STAINED CEDAR (BASE TRIM) PRECAST CONCRETE CAP SPLIT —FACED CMU WALL FLEXIBLE FLASHING FINISH GRADE (RE: CIVIL) CONNECT DOWNSPOUTS —TO DRAIN PIPE BELOW 4 ��/ (RE: CIVIL) A1 00B 4 NW ELEVATION - SHELTER SCALE: z" = 1' -0" h RIDGE CAP 8162' -7" BERRIDGE CEE —LOCK RIDGE CLOSURE PREFINISHED METAL CEE —LOCK ROOF PANEL PRE — FINISHED METAL GUTTER 2x10 STAINED CEDAR FASCIA TRIM 1x6 STAINED CEDAR (CAP TRIM) EXTERIOR STAINED CEDAR BOARD & BATT WALL 1x4 STAINED CEDAR (TRIM PIECE) 1x4 STAINED CEDAR (BASE TRIM) PRECAST CONCRETE CAP SPLIT —FACED CMU WALL BILE FLASHING FINISH GRADE (RE: CIVIL) 2 SE ELEVATION - BOILER BUILDING SCALE: z" = 1' -0" 4 Al 0013 3 NE ELEVATION - SHELTER SCALE: z" = 1' -0" 4 Al 0013 1SW ELEVATION - BOILER BUILDING SCALE: z" = 1' -0" BOILER FLUE BOILER FLUE (RE: MEP) (RE: MEP) IIART DESIG S jjf1 5,8 j DEPT. OF PUBLIC WORKS 5,8 A100B FLUE STORM COLLAR & w A100B 2 BERRIDGE CEE —LOCK FLASHING (RE: MEP) EDWARDS, CO 81632 BERRIDGE CEE —LOCK RIDGE CLOSURE PO BOX 8258 gk WALL CAP BRECKENRIDGE, CO 80424 RIDGE CLOSURE t: 970.453.5878 8162' -7" DENVER, CO 80216 PREFINISHED METAL t: 303.292.3388 MEP ENGINEER E CONS. ENG. 110 E. BEAVER CRK BLVD. CEE —LOCK ROOF PANEL AVON, CO 81620 PREFINISHED METAL STRUCTURAL ENGINEER 1169 HILLTOP PKWY STE 206A CEE —LOCK ROOF PANEL STEAMBOAT, CO 80487 t: 970.846.7970 DESIGNER METAL SNOW GUARD P.O. BOX 2117 ROOF EAVE MILLS, WY 82644 ELECTRIC SNOWMELT t: 307.315.8054 8160' -2" O EAVE (RE: ELEC.) N cz PRE — FINISHED METAL PRE — FINISHED METAL N GUTTER GUTTER 3" DIA PREFINISHED 3" DIA PREFINISHED 2x10 STAINED CEDAR 2x10 STAINED CEDAR MTL. DOWNSPOUT MTL. DOWNSPOUT FASCIA TRIM FASCIA TRIM LIGHT SCONCE ` 1x6 STAINED CEDAR 1x6 STAINED (RE: ELEC.) ❑ CTRIM) CAP U 3' —0„ 2x6 S AIINED CEDAR EXTERIOR STAINED EXTERIOR STAINED C/) LINTEL CEDAR BOARD & CEDAR BOARD & 1x4 STAINED CEDAR BATT WALL FAN GATT WALL ` (TRIM PIECE) 1x4 STAINED CEDAR ( ELL MCP; \ 2x4 STAINED CEDAR (TRIM PIECE) ICU DOOR TRIM L 1x4 STAINED CEDAR N0. 1 Oct. 24, 2011 1x4 STAINED CEDAR (BASE TRIM) WALL QAPjh OIL WALL CAP 60% CD Pricing Set o > (BASE TRIM) N G 8155'— 1 ' 8155 —1 , ' ■ Boiler Bldg. I CONCRETE P : =• :• '.< RECAST CONCRETE N G N 0 CAPCAST CAP ... . -...: ..,:- • ..:: _ .:.... ,•. ••. .. ...' ,, , .' SPLIT FACED CMU - ,� WALL SPLIT FACED CMU .. .. :. • . ,: ..:. :.. ... _ .: ,. . ...:.......:. :... .. :. ... _ r - W METAL WALL - WITHO ...,;,, KICKPLATE 0TH . : -..,.. ..........;:.: ..:....... FLEXIBLE FLASHING : •... • . - ., ., I FINISH GRADE :..::;�.' ;." ..; :. ..- .. ,.. - F.;'.: �• -' ." (RE. CIVIL) '�. :` ;.. f:_�.; SIDEWALK PAVING .- � , , �' � RE: LANDSCAPE �( ) FF LEVEL FF LEVEL 8151' -6 8151' -6" 4 Al 0013 3 NE ELEVATION - SHELTER SCALE: z" = 1' -0" 4 Al 0013 1SW ELEVATION - BOILER BUILDING SCALE: z" = 1' -0" NOT FOR CONSTRUCTION MARY IIART DESIG OWNER DEPT. OF PUBLIC WORKS 1309 ELKHORN DRIVE VAIL, CO 81632 t: 970.479.2158 CIVIL ENGINEER 34510U.S.6 UNIT A-9 EDWARDS, CO 81632 t: 970.926.3373 LANDSCAPE _IVlARTFART_D`ESTGN1EU__ ARCHITECT PO BOX 8258 BRECKENRIDGE, CO 80424 t: 970.453.5878 3507 RINGSBY CT, STE 117 DENVER, CO 80216 t: 303.292.3388 MEP ENGINEER E CONS. ENG. 110 E. BEAVER CRK BLVD. STE 202 AVON, CO 81620 t: 970.949.6108 STRUCTURAL ENGINEER 1169 HILLTOP PKWY STE 206A STEAMBOAT, CO 80487 t: 970.846.7970 DESIGNER CONSULTING & ENG P.O. BOX 2117 MILLS, WY 82644 t: 307.315.8054 N cz N U (3) U C/) ® 0 ICU R E V I S 1 0 N S N0. 1 Oct. 24, 2011 DRB Final Submission 2 Nov. 07; 2011 DD Pricing Set 3 Dec. 02; 2011 60% CD Pricing Set D R A W I N G T I T L E: ■ Boiler Bldg. ■ Elevations D R A W I N G N 0 A-200B } 424? r • �i i t - � 1 t 1 . �� � nab _ � ti �� ` `. �� h� �• -: . I EEO c a�4• e ��I4 \� T`: r k ) _ r. , / � : • t . fir\+ r l 1 � -'�� !, {! ;" � q 1� t y 4 �I N i s - X