MARY HART DESIGN
land planning a landscape architecture;
post office box 8258 p. 970- 389 -3583
breckenridge Colorado 80424 maryhandesign @gmail.com
Site Plan
L'ionshead Concert Hall Plaza
Vail, Colorado
TOW
Scale: 1'= 10'
Date: 11.7.11
z
0
N
Y
U
O
w
0
O 1
�J
O J
www
Cf)W
= V ry
~ U O
goo
w
U
w
0
H
X r
w dL.
N
I
PREFINISHED CEE -LOCK
METAL ROOF PANEL ON
SHEET MEMBRANE
WATERPROOFING
PANEL PAN AROUND
EAVE FLASHING
MTL DRIP FLASHING
43/4 "x6" MTL GUTTER-
3" DIA MTL DOWNSPOUT
2x10 STAINED CEDAR
FASCIA TRIM
—
1 x6 T &G V- GROOVE
DECKING SOFFIT
1x6 STAINED CEDAR
(CAP TRIM)
1' UON (RE: ROOF PLAN)
EXT. STAINED CEDAR
BOARD & BATT WALL
H12SCALE: ARDWARE MOUNTING 1 JTYP. HINGE
B ATT INSULATION
5/8" TYPE "X"
GYPSUM WALLBOARD
(2) 2x6 WOOD HEADER
EXTERIOR
SIDE
2x4 STAINED CEDAR
WOOD TRIM
SEALANT & BACKER ROD
WEATHER BARRIER
SHIM AS REQUIRED
6Y2„
10 HM DOOR HEAD
SCALE: 3" = V -0"
NTERIOR
SIDE
c�
Z_
S
PLAN
Sc
SECTION
INTERIOR SIDE
PLAN
61„
2
INTERIOR SIDE
EXTERIOR SIDE
91 HR. RATED EXT. WALL
SCALE: 1 z" = 1' -0"
GRID
5:12 ROOF PITCH
I
T.O. WALL /BEARING ELEV.
60' -1 1/2"
NOTCH RAFTER AS
REQUIRED FOR STUD WALL
(RE: STRUCT.)
BATT INSULATION
EXTERIOR CLADDING,
SEE ELEVATIONS
NOTE: EXTERIOR VENEER
NOT INCLUDED IN WALL
THICKNESS
FIRESTOPPING
)R SIDE
5/8" TYPE
"X" GYPSUM
WALLBOARD
5/8" TYPE
"X" GYPSUM
WALLBOARD
2X6 WOOD STUD
BATT INSULATION
5/8" TYPE "X"
GYPSUM WALLBOARD
EXTERIOR CLADDING,
SEE ELEVATIONS
NOTE: EXTERIOR VENEER
NOT INCLUDED IN WALL
THICKNESS
5/8" GYPSUM WALL BOARD
THERMAL BARRIER
CONFORMING WITH 2003
IBC SECTION 2603
NOTE:
1. SEE OTHER METAL ROOF DETAILS FOR
ADDITIONAL INFORMATION.
8 ROOF OVERHANG - BOILER BUILDING
SCALE: 1" = V -0"
2"
�E
1/8" TYPE "X„
YPSUM WALLBOARD
ATT INSULATION
x6 WOOD STUD
HIM AS REQUIRED
EXTERIOR SIDE
/8" TYPE "X"
YPSUM WALLBOARD
FEATHER BARRIER
EALANT & BACKER
OD
—x4 STAINED CEDAR WOOD TRIM
EXTERIOR CLADDING,
SEE ELEVATIONS
NOTE: EXTERIOR VENEER NOT
INCLUDED IN WALL THICKNESS
7 HM DOORJAMB
SCALE: 3" = V -0"
PLAN VIEW
THEIR BARRIER
3/8" THICK STAINED CEDAR PLYWOOD BD.
1x4 STAINED CEDAR BATT
V -0" O.C.
(TYP.)
ELEVATION
6 BOARD & BATT SIDING - BOILER BUILDING
SCALE: 1 2' = V -0"
SNOW SCREEN BERRIDGE CEE -LOCK
FASTENERS BY METAL ROOF RIDGE CLOSURE
MFR
CLOSED -CELL I PREFINISHED METAL
POLYURETHANE INSULATION CEE -LOCK ROOF PANEL
(6" THICK)
ROOF SHEATHING
BLOCKING AS REQUIRED (RE: STRUCT.)
BETWEEN ROOF JOISTS SHEET MEMBRANE
WATERPROOFING
^o`
5/8" GYPSUM WALL BOARD
THERMAL BARRIER CONFORMING
WITH 2003 IBC SECTION 2603 4x10 RIDGE BEAM
(RE: STRUCT)
5 METAL ROOF RIDGE - BOILER BUILDING
SCALE: 1" = V -0"
SNOW -MELT BOILER ROOM
2x6 STUD WALL W /5"
BATT INSULATION —
(RE: PLAN)
5/8" TYPE "X" GYPSUM
WALLBOARD
1x8 STAINED CEDAR TRIM
EJ W /BACKER ROD &
SEALANT, TYP
DITCH SLAB TO FLOOR DRAIN
(RE: FLOOR PLAN)
FF SLAB @ PERIMETER
IL 8151' -6" a
a
CONCRETE SLAB -
(RE: STRUCT.)
U
Of
F—
w
GRID
ji 1
Q
°I
I
8" THICK STAINED
CEDAR PLY BOARD
1x4 STAINED CEDAR BATT
8
51, TYPE "X" GYPSUM
WALLBOARD
SLOPE "' /FT. TO DRAIN
MTL FLASHING SET
IN BED OF SEALANT
PRECAST CONC. CAP
4X SPLIT -FACED CMU
WALL
FAIR BARRIER
FLEXIBLE FLASHING
2" (MIN.) ABUTTING LANDSCAPE
2" ABUTTING SIDEWALK @ DOOR
FINISH GRADE
7LI (REL= VARIES
1111t
E: CIVIL)
LANDSCAPE TREATMENT
(RE: LANDSCAPE)
CONCRETE FOUNDATION
W /TURNED -IN FOOTING
a , (RE: STRUCT.)
RE: T ?UCT.
a a WATERPROOFING MEMBRANE &
DRAINAGE SYSTEM w /BOARD
INSULATION
I
4 WALL SECTION - BOILER BUILDING
SCALE: 1" = V -0"
3" DIA PREFINISHED
MTL. DOWNSPOUT
3" DIA PREFINISHED
MTL. DOWNSPOUT
2
3RCP PLAN - BOILER BUILDING
S CALE :: z" = 1' -0"
S
5,e'1 �\
(2) 4' L.
FLOURESCENT LIGHT
FIXTURES (RE: ELEC.)
EXTERIOR BOARD &
BATT WALL
1x6 T &G V— GROOVE
DECKING SOFFIT
4x10 ROOF RIDGE
BEAM
-1x6 STAINED CEDAR
(CAP TRIM)
5/8" GYPSUM WALL
BOARD THERMAL
BARRIER
CONFORMING WITH
2003 IBC SECTION
2603
2x8 ROOF RAFTERS
BEHIND GWB CAD 16" O.0
(DASHED) (RE:STRUCT.)
2x10 STAINED CEDAR
FASCIA TRIM
-PRE— FINISHED METAL
GUTTER
\—BERRIDGE CEE —LOCK
RIDGE CLOSURE
PREFINISHED METAL
CEE —LOCK ROOF PANE
METAL SNOW GUARD
ELECTRIC SNOWMELT
EAVE
PRE — FINISHED METAL
GUTTER
3" DIA PREFINISHED
MTL. DOWNSPOUT
2 ROOF PLAN - BOILER BUILDING
SCALE: 2' = 1' -0"
1FLOOR PLAN - BOILER BUILDING
SCALE: 2' = 1' -0"
'E "X" GYPSUM
IOARD
IOR BOARD &
WALL
OF ROOF
E— DASHED)
OF PRECAST
CAP
HOLLOW METAL
W /BACKER
3c SEALANT
�
o�' 9
I
I
CONSTRUCTION
" O.D.
THROUGH
(RE: MEP)
I IART DL-SI�N
DEPT. OF PUBLIC WORKS
1309 ELKHORN DRIVE
VAIL, CO 81632
I
I
t: 970.479.2158
CIVIL
ENGINEER
BOILER FLUE
ROOF
EDWARDS, CO 81632
t: 970.926.3373
ARCHITECT
PO BOX 8258
BRECKENRIDGE, CO 80424
t: 970.453.5878
ARCHITECT
4240 ARCHITECTURE INC
3507 RINGSBY CT, STE 117
DENVER, CO 80216
I
I
t: 303.292.3388
ENGINEER
110 E. BEAVER CRK BLVD.
STE 202
AVON, CO 81620
t: 970.949.6108
I
I
1169 HILLTOP PKWY
STE 206A
STEAMBOAT, CO 80487
t: 970.846.7970
IRRIGATION
DESIGNER
CONSULTING & ENG
P.O. BOX 2117
MILLS, WY 82644
t: 307.315.8054
N
cz
N
co
O
U
(2) 4' L.
FLOURESCENT LIGHT
FIXTURES (RE: ELEC.)
EXTERIOR BOARD &
BATT WALL
1x6 T &G V— GROOVE
DECKING SOFFIT
4x10 ROOF RIDGE
BEAM
-1x6 STAINED CEDAR
(CAP TRIM)
5/8" GYPSUM WALL
BOARD THERMAL
BARRIER
CONFORMING WITH
2003 IBC SECTION
2603
2x8 ROOF RAFTERS
BEHIND GWB CAD 16" O.0
(DASHED) (RE:STRUCT.)
2x10 STAINED CEDAR
FASCIA TRIM
-PRE— FINISHED METAL
GUTTER
\—BERRIDGE CEE —LOCK
RIDGE CLOSURE
PREFINISHED METAL
CEE —LOCK ROOF PANE
METAL SNOW GUARD
ELECTRIC SNOWMELT
EAVE
PRE — FINISHED METAL
GUTTER
3" DIA PREFINISHED
MTL. DOWNSPOUT
2 ROOF PLAN - BOILER BUILDING
SCALE: 2' = 1' -0"
1FLOOR PLAN - BOILER BUILDING
SCALE: 2' = 1' -0"
'E "X" GYPSUM
IOARD
IOR BOARD &
WALL
OF ROOF
E— DASHED)
OF PRECAST
CAP
HOLLOW METAL
W /BACKER
3c SEALANT
�
o�' 9
NOT FOR
CONSTRUCTION
MARY
I IART DL-SI�N
DEPT. OF PUBLIC WORKS
1309 ELKHORN DRIVE
VAIL, CO 81632
t: 970.479.2158
CIVIL
ENGINEER
34510 U.S. 6 UNIT A -9
EDWARDS, CO 81632
t: 970.926.3373
ARCHITECT
PO BOX 8258
BRECKENRIDGE, CO 80424
t: 970.453.5878
ARCHITECT
4240 ARCHITECTURE INC
3507 RINGSBY CT, STE 117
DENVER, CO 80216
t: 303.292.3388
ENGINEER
110 E. BEAVER CRK BLVD.
STE 202
AVON, CO 81620
t: 970.949.6108
bIKUUIUKAL
ENGINEER
1169 HILLTOP PKWY
STE 206A
STEAMBOAT, CO 80487
t: 970.846.7970
IRRIGATION
DESIGNER
CONSULTING & ENG
P.O. BOX 2117
MILLS, WY 82644
t: 307.315.8054
N
cz
N
co
O
U
co
>
CU
L.
. CU
(D
>
U
°
Cn
O
o
V
(z
R E V I S
1 0 N S
NO.
1 Oct. 24, 2011
DRIB Final Submission
2 Nov. 07, 2011
DD Pricing Set
3 Dec. 02, 2011
60% CD Pricing Set
D R A W I
N G
T I T L E
Boiler Bldg.
Plans & Details
D R A W I
N G
N 0
Aml OOB
BOILER FLUE
(RE: MEP)
B BERRIDGE CEE —LOCK A
OL RIDGE CAP RIDGE CLOSURE
8162' -7"
WALL CAP
8155' -1"
FF LEVEL
8151' -6"
PREFINISHED METAL
CEE —LOCK ROOF PANEL
METAL SNOW GUARD
PRE — FINISHED METAL
GUTTER
2x10 STAINED CEDAR
FASCIA TRIM
1x6 STAINED CEDAR
(CAP TRIM)
3" DIA PREFINISHED MTL.
DOWNSPOUT
1x4 STAINED CEDAR
(TRIM PIECE)
EXTERIOR STAINED
CEDAR BOARD &
BATT WALL
COMBUSTION AIR
DUCT (RE: MEP)
1x4 STAINED CEDAR
(BASE TRIM)
PRECAST CONCRETE
CAP
SPLIT —FACED CMU
WALL
FLEXIBLE FLASHING
FINISH GRADE
(RE: CIVIL)
CONNECT DOWNSPOUTS
—TO DRAIN PIPE BELOW
4 ��/ (RE: CIVIL)
A1 00B
4 NW ELEVATION - SHELTER
SCALE: z" = 1' -0"
h RIDGE CAP
8162' -7"
BERRIDGE CEE —LOCK
RIDGE CLOSURE
PREFINISHED METAL
CEE —LOCK ROOF PANEL
PRE — FINISHED METAL
GUTTER
2x10 STAINED CEDAR
FASCIA TRIM
1x6 STAINED CEDAR
(CAP TRIM)
EXTERIOR STAINED
CEDAR BOARD &
BATT WALL
1x4 STAINED CEDAR
(TRIM PIECE)
1x4 STAINED CEDAR
(BASE TRIM)
PRECAST CONCRETE
CAP
SPLIT —FACED CMU
WALL
BILE FLASHING
FINISH GRADE
(RE: CIVIL)
2 SE ELEVATION - BOILER BUILDING
SCALE: z" = 1' -0"
4
Al 0013
3 NE ELEVATION - SHELTER
SCALE: z" = 1' -0"
4
Al 0013
1SW ELEVATION - BOILER BUILDING
SCALE: z" = 1' -0"
BOILER FLUE
BOILER FLUE
(RE: MEP)
(RE: MEP)
IIART DESIG
S jjf1 5,8
j
DEPT. OF PUBLIC WORKS
5,8
A100B
FLUE STORM COLLAR &
w
A100B 2
BERRIDGE CEE —LOCK
FLASHING (RE: MEP)
EDWARDS, CO 81632
BERRIDGE CEE —LOCK
RIDGE CLOSURE
PO BOX 8258
gk WALL CAP
BRECKENRIDGE, CO 80424
RIDGE CLOSURE
t: 970.453.5878
8162' -7"
DENVER, CO 80216
PREFINISHED METAL
t: 303.292.3388
MEP
ENGINEER
E CONS. ENG.
110 E. BEAVER CRK BLVD.
CEE —LOCK ROOF PANEL
AVON, CO 81620
PREFINISHED METAL
STRUCTURAL
ENGINEER
1169 HILLTOP PKWY
STE 206A
CEE —LOCK ROOF PANEL
STEAMBOAT, CO 80487
t: 970.846.7970
DESIGNER
METAL SNOW GUARD
P.O. BOX 2117
ROOF EAVE
MILLS, WY 82644
ELECTRIC SNOWMELT
t: 307.315.8054
8160' -2"
O EAVE (RE: ELEC.)
N
cz
PRE — FINISHED METAL
PRE — FINISHED METAL
N
GUTTER
GUTTER
3" DIA PREFINISHED
3" DIA PREFINISHED
2x10 STAINED CEDAR
2x10 STAINED CEDAR
MTL. DOWNSPOUT
MTL. DOWNSPOUT
FASCIA TRIM
FASCIA TRIM
LIGHT SCONCE
` 1x6 STAINED CEDAR
1x6 STAINED
(RE: ELEC.)
❑
CTRIM)
CAP
U
3' —0„ 2x6 S AIINED CEDAR
EXTERIOR STAINED
EXTERIOR STAINED
C/)
LINTEL
CEDAR BOARD &
CEDAR BOARD &
1x4 STAINED CEDAR
BATT WALL
FAN
GATT WALL
` (TRIM PIECE)
1x4 STAINED CEDAR
( ELL MCP;
\ 2x4 STAINED CEDAR
(TRIM PIECE)
ICU
DOOR TRIM
L
1x4 STAINED CEDAR
N0.
1 Oct. 24, 2011
1x4 STAINED CEDAR
(BASE TRIM)
WALL QAPjh
OIL WALL CAP
60% CD Pricing Set
o > (BASE TRIM)
N G
8155'— 1 '
8155 —1 , '
■
Boiler Bldg.
I CONCRETE
P : =• :• '.<
RECAST CONCRETE
N G
N 0
CAPCAST
CAP ... . -...:
..,:-
• ..::
_ .:.... ,•. ••. .. ...' ,, , .' SPLIT FACED CMU
-
,� WALL
SPLIT FACED CMU .. .. :. • . ,: ..:. :..
... _ .:
,. . ...:.......:. :...
.. :. ...
_
r
- W METAL
WALL
-
WITHO
...,;,,
KICKPLATE 0TH
. : -..,.. ..........;:.: ..:.......
FLEXIBLE FLASHING : •... • . - .,
.,
I
FINISH GRADE
:..::;�.' ;." ..; :. ..- .. ,.. - F.;'.: �• -' ."
(RE. CIVIL)
'�. :` ;.. f:_�.;
SIDEWALK PAVING
.- � , , �' � RE: LANDSCAPE
�( )
FF LEVEL
FF LEVEL
8151' -6
8151' -6"
4
Al 0013
3 NE ELEVATION - SHELTER
SCALE: z" = 1' -0"
4
Al 0013
1SW ELEVATION - BOILER BUILDING
SCALE: z" = 1' -0"
NOT FOR
CONSTRUCTION
MARY
IIART DESIG
OWNER
DEPT. OF PUBLIC WORKS
1309 ELKHORN DRIVE
VAIL, CO 81632
t: 970.479.2158
CIVIL
ENGINEER
34510U.S.6 UNIT A-9
EDWARDS, CO 81632
t: 970.926.3373
LANDSCAPE _IVlARTFART_D`ESTGN1EU__
ARCHITECT
PO BOX 8258
BRECKENRIDGE, CO 80424
t: 970.453.5878
3507 RINGSBY CT, STE 117
DENVER, CO 80216
t: 303.292.3388
MEP
ENGINEER
E CONS. ENG.
110 E. BEAVER CRK BLVD.
STE 202
AVON, CO 81620
t: 970.949.6108
STRUCTURAL
ENGINEER
1169 HILLTOP PKWY
STE 206A
STEAMBOAT, CO 80487
t: 970.846.7970
DESIGNER
CONSULTING & ENG
P.O. BOX 2117
MILLS, WY 82644
t: 307.315.8054
N
cz
N
U
(3)
U
C/)
®
0
ICU
R E V I S
1 0 N S
N0.
1 Oct. 24, 2011
DRB Final Submission
2 Nov. 07; 2011
DD Pricing Set
3 Dec. 02; 2011
60% CD Pricing Set
D R A W I
N G
T I T L E:
■
Boiler Bldg.
■
Elevations
D R A W I
N G
N 0
A-200B
}
424?
r
• �i
i
t -
�
1
t 1
. �� � nab _ � ti �� ` `. �� h� �• -: .
I
EEO c a�4•
e ��I4
\� T`:
r
k
) _
r. , / � : • t . fir\+ r l 1 � -'�� !, {! ;"
�
q
1�
t
y
4
�I
N
i
s -
X