HomeMy WebLinkAboutDRB110297 colored renderingsit
EXISTING NORTH ELEVATION
A4.3 SCALE: 118" = P -0"
T.O. ROOF
149' -5°
T.O. EXISTING; ROOF
145' -2°
T.O. ROOF
142'-7"
FOURTH FLOOR
132' -1 1 °
THIRD FLOOR �
123' -2'
SECOND FLOOR j4
-- 112' -5°
FIRST FLOOR
101' -4°
PROPOSED NORTH ELEVATION
SCALE: 118" = 1' -0"
PARTIAL ELEVATION
SCALE: 118" = 1' -0"
T.O. EXISTING ROOF
145' -2°
FOURTH FLOOR
132-11'
c,
o.
THIRD FLOOR
123' -2"
SECOND FLOOR
112-50
FIRST FLOOR
102' -4°
J� T.O. ROOF
142' -7"
FOURTH FLOOR
7 132' -11"
c.
THIRD FLOOR
123-2"
0
SECOND FLOOR
1 12' -5"
0
FIRST FLOOR
102` -4"
SCALE: 118" = P -O"
n?
N
a1
c�
ib
T.O. ROOF
142' -10"
FOURTH FLOOR
130` -7"
THIRD FLOOR
120' -10"
SECOND FLOOR
110' -1"
FIRST FLOOR
100' -0"
EXISTING SOUTH ELEVATION
SCALE: 118" = P-0'
a
T.O. ROOF
142' -l0"
FOURTH FLOOR
130' -7°
THIRD FLOOR
120' -10"
SECOND FLOOR
110' -1'
FIRST FLOOR
100' -0"
L
_1
1
PROPOSED SOUTH ELEVATION
SCALE: 118" = P -D"
LION SQUARE LODGE -EAST BUILDING
A4.2 -NORTH /SOUTH ELEVATIONS
SCALE: 1/8" = 1' -0°
MELICK ASSOCIATES INC
7-25-11
8TH FLOOR
EL 169' -1 1"
7TH FLOOR ,
EL. 160' -5°
6TH FLOOR
EL. 150'-11"
5TH FLOOR
EL. 141' -5"
4TH FLOOR
EL. 131' -1 1"
3RD FLOOR
EL. 121' -3"
2ND FLOOR ,
EL. 110' -3 1/2'
1ST FLOOR
EL. 100' -0"
10"Jil d
"Mimni
i
i
i
i
i
i
i
i
2ND FLOOR
EL. 110'-3 112°
L--------- --- - - - --- ---- - - - - -- ----------- - - - ---
1 ST FLOOR
EL. 100' -0'
z
0
H
0
wW
Q�
oz
�Q
a�
�x
z�
0
W
U
a
W
O
z
o0
a
o
0
T.O. ROOF
145' -2'
FOURTH FLOOR
132' -1 1 '
THIRD FLOOD
123' -2"
SECOND FLOOR
112' -5'
FIRST FLOOR
142' -4`
T.O. CHIMNEY
151' -3°
T.O. ROOF
149' -5°
T.O. EXISTING ROOF
145'-2"
T.O. ROOF
142-7
FOURTH FLOOR
132 -11"
THIRD FLOOR
123'_2,,
SECOND FLOOR
112'-5"
FIRST FLOOR
102'-4:`
EXISTING WEST ELEVATION
SCALE: 1/8" = l' -O'
PROPOSED WEST ELEVATION
SCALE. 1 /8" = l' -O"
T.O. CHIMNEY
14'9' -5'
T.O. CHIMNEY �
156'_0„
T.Q. ROOF
152' -0° T
T.O. ROOF
14$' -4°
T.O. ROOF
147-4`
T.Q. EXISTING ROOF
142' -10"
T.O. ROOF
140' -3'
T.O. EXISTING ROOF
131' -11"
FOURTH FLOOR
130' -7"
LION SQUARE LODGE -EAST BUILDING
A41 -WEST ELEVATIONS
scnLe: va. = r -a.
7-25-11
MELICK ASSOCIATES INC
THIRD FLOOD
120' -10"
SECOND FLOOR
110' =1''
FIRST FLOOR
99' -0'
BASEMENT
87 " -10 112°
T.O. ROOF
`r 152' -0"
OL T.O. ROOF
148' -4"
T.O. ROOF T
147.4°
OL T.O. EXISTING ROOF
142' -10"
OL T.O. ROOF
140' -3"
OL T.O. EXISTING ROOF
131' -1 V
OL FOURTH FLOOR
130' -7°
OL THIRD FLOOR
120' -10"
OL SECOND FLOOR
110' -1°
1 FIRST FLOOR
BASEMENT
87- 101/2'
mill
PEI
IVI io I I
EXISTING EAST ELEVATION
SCALE: 1/&' - 1' -0"
�, THIRD FLOOR
123-2"
OL SECOND FLOOR
112'-5" -
FIRST FLOOR
101'-4"
PROPOSED EAST ELEVATION
SCALE: 1/8" = l' -0"
LION SQUARE LODGE -EAST BUILDING
7-25-11
A4,2 - EAST ELEVATIONS
SCALE: 1/8" = V -0"
MELICK ASSOCIATES INC
EXISTING EAST ELEVATION
EAST OF STAIR TOWER
SCALE: 1/8" = 1' -Q"
PROPOSED WEST ELEVATION
WEST OF STAIR TOWER cz INFILL
SCALE: 1/8" = P-0'
PROPOSED EAST ELEVATION
EAST OF STAIR TOWER 9 INFILL
SCALE: 1/8" = 1' -0'°
W
C'7
Q
O
a
W
d
d
z
0
0
z
U
O
z
0
H
0
z
w
x
c7
z
Q
a
x
0
W
U
a
W
x
z
0
a
3
0
in
00
o
j0
1 4
0
u
h
n
o a
� u
w, N.
a
� o
a ® z
a
u - M
DD PRICING 8 -8 -1 1
ISSUED FOR: DATE:
THESE DRAWINGS AND SPECIFICATIONS AND THE
IDEAS, DESIGNS AND ARRANGEMENTS
REPRESENTED THEREBY ARE AND SHALL REMAIN
PROPERTY OF THE ARCHITECT, AND NO PART
THEREOF SHALL BE COPIED, DISCLOSED TO
OTHERS, OR USED IN CONNECTION WITH ANY
WORK OR PROJECT FOR WHICH THEY HAVE BEEN
PREPARED WITHOUT THE WRITTEN CONSENT OF
THE ARCHITECT" VISUAL CONTACT WITH THESE
DRAWINGS OR SPECIFICATIONS SHALL
CONSTITUTE CONCLUSIVE EVIDENCE OF
ACCEPTANCE OF THESE RESTRICTIONS. WRITTEN
DIMENSIONS ON THESE DRAWINGS SHALL HAVE
PRECEDENCE OVER SCALED DIMENSIONS.
CONTRACTORS SHALL VERIFY, AND BE RESPONSIBLE
FOR ALL DIMENSIONS AND CONDITIONS ON THE
JOB, AND THIS OFFICE MUST BE NOTIFIED OF ANY
VARIATIONS FROM THE DIMENSIONS AND
CONDITIONS SHOWN BY THESE DRAWINGS.
0 2011 MELICK ASSOCIATES, INC.
EXISTING AND PROPOSED
STAIR ELEVATIONS
A4.4
_
by
_
z
... ......
.
PROPOSED WEST ELEVATION
WEST OF STAIR TOWER cz INFILL
SCALE: 1/8" = P-0'
PROPOSED EAST ELEVATION
EAST OF STAIR TOWER 9 INFILL
SCALE: 1/8" = 1' -0'°
W
C'7
Q
O
a
W
d
d
z
0
0
z
U
O
z
0
H
0
z
w
x
c7
z
Q
a
x
0
W
U
a
W
x
z
0
a
3
0
in
00
o
j0
1 4
0
u
h
n
o a
� u
w, N.
a
� o
a ® z
a
u - M
DD PRICING 8 -8 -1 1
ISSUED FOR: DATE:
THESE DRAWINGS AND SPECIFICATIONS AND THE
IDEAS, DESIGNS AND ARRANGEMENTS
REPRESENTED THEREBY ARE AND SHALL REMAIN
PROPERTY OF THE ARCHITECT, AND NO PART
THEREOF SHALL BE COPIED, DISCLOSED TO
OTHERS, OR USED IN CONNECTION WITH ANY
WORK OR PROJECT FOR WHICH THEY HAVE BEEN
PREPARED WITHOUT THE WRITTEN CONSENT OF
THE ARCHITECT" VISUAL CONTACT WITH THESE
DRAWINGS OR SPECIFICATIONS SHALL
CONSTITUTE CONCLUSIVE EVIDENCE OF
ACCEPTANCE OF THESE RESTRICTIONS. WRITTEN
DIMENSIONS ON THESE DRAWINGS SHALL HAVE
PRECEDENCE OVER SCALED DIMENSIONS.
CONTRACTORS SHALL VERIFY, AND BE RESPONSIBLE
FOR ALL DIMENSIONS AND CONDITIONS ON THE
JOB, AND THIS OFFICE MUST BE NOTIFIED OF ANY
VARIATIONS FROM THE DIMENSIONS AND
CONDITIONS SHOWN BY THESE DRAWINGS.
0 2011 MELICK ASSOCIATES, INC.
EXISTING AND PROPOSED
STAIR ELEVATIONS
A4.4